Model 167A11 Ballistics shot shell pressure sensor, 15k psi, floating clamp nut design Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com Warranty, Service, Repair, and Return Policies and Instructions The information contained in this document supersedes all similar information that may be found elsewhere in this manual. Total Customer Satisfaction – PCB Piezotronics guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any PCB product, PCB will repair, replace, or exchange it at no charge. You may also choose to have your purchase price refunded in lieu of the repair, replacement, or exchange of the product. Service – Due to the sophisticated nature of the sensors and associated instrumentation provided by PCB Piezotronics, user servicing or repair is not recommended and, if attempted, may void the factory warranty. Routine maintenance, such as the cleaning of electrical connectors, housings, and mounting surfaces with solutions and techniques that will not harm the physical material of construction, is acceptable. Caution should be observed to insure that liquids are not permitted to migrate into devices that are not hermetically sealed. Such devices should only be wiped with a dampened cloth and never submerged or have liquids poured upon them. Repair – In the event that equipment becomes damaged or ceases to operate, arrangements should be made to return the equipment to PCB Piezotronics for repair. User servicing or repair is not recommended and, if attempted, may void the factory warranty. Calibration – Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data. Equipment calibration cycles are typically established by the users own quality regimen. When in doubt about a calibration cycle, a good “rule of thumb” is to recalibrate on an annual basis. It is also good practice to recalibrate after exposure to any severe temperature extreme, shock, load, or other environmental influence, or prior to any critical test. PCB Piezotronics maintains an ISO9001 certified metrology laboratory and offers calibration services, which are accredited by A2LA to ISO/IEC 17025, with full traceablility to N.I.S.T. In addition to the normally supplied calibration, special testing is also available, such as: sensitivity at elevated or cryogenic temperatures, phase response, extended high or low frequency response, extended range, leak testing, hydrostatic pressure testing, and others. For information on standard recalibration services or special testing, contact your local PCB Piezotronics distributor, sales representative, or factory customer service representative. Returning Equipment – Following these procedures will insure that your returned materials are handled in the most expedient manner. Before returning any equipment to PCB Piezotronics, contact your local distributor, sales representative, or factory customer service representative to obtain a Return Materials Authorization (RMA) Number. This RMA number should be clearly marked on the outside of all package(s) and on the packing list(s) accompanying the shipment. A detailed account of the nature of the problem(s) being experienced with the equipment should also be included inside the package(s) containing any returned materials. PCB for a complete statement of our warranty. Expendable items, such as batteries and mounting hardware, are not covered by warranty. Mechanical damage to equipment due to improper use is not covered by warranty. Electronic circuitry failure caused by the introduction of unregulated or improper excitation power or electrostatic discharge is not covered by warranty. A Purchase Order, included with the returned materials, will expedite the turn-around of serviced equipment. It is recommended to include authorization on the Purchase Order for PCB to proceed with any repairs, as long as they do not exceed 50% of the replacement cost of the returned item(s). PCB will provide a price quotation or replacement recommendation for any item whose repair costs would exceed 50% of replacement cost, or any item that is not economically feasible to repair. For routine calibration services, the Purchase Order should include authorization to proceed and return at current pricing, which can be obtained from a factory customer service representative. Contact Information – International customers should direct all inquiries to their local distributor or sales office. A complete list of distributors and offices can be found at www.pcb.com. Customers within the United States may contact their local sales representative or a factory customer service representative. A complete list of sales representatives can be found at www.pcb.com. Toll-free telephone numbers for a factory customer service representative, in the division responsible for this product, can be found on the title page at the front of this manual. Our ship to address and general contact numbers are: Warranty – All equipment and repair services provided by PCB Piezotronics, Inc. are covered by a limited warranty against defective material and workmanship for a period of one year from date of original purchase. Contact DOCUMENT NUMBER: 21354 DOCUMENT REVISION: B ECN: 17900 PCB Piezotronics, Inc. 3425 Walden Ave. Depew, NY 14043 USA Toll-free: (800) 828-8840 24-hour SensorLineSM: (716) 684-0001 Website: www.pcb.com E-mail: info@pcb.com OPERATION MANUAL FOR Series 167 BALLISTICS PRESSURE SENSOR 1.0 INTRODUCTION Series 167 are charge mode, general purpose ballistics sensors with a welded diaphragm and a rugged quartz element package. The sensors’ welded diaphragms provide better transient thermal characteristics that are important for ballistic applications. Series 167 is approved by SAAMI for against-the-case (undrilled) shotshell production testing of plastic-cased ammunition. Chamber pressure is sensed by the sensor as the round is fired. In addition to ballistics testing, the 167 Series can be used for hydraulic and pneumatic test applications. 2.0 DESCRIPTION Figure 1 below shows the internal construction and external configuration of the 167 Series. 3.0 1 INSTALLATION The 167 Series mounts directly in existing ports machined for PCB Models 118A, 119A, 108A, 109A and others. See above figure. A torque wrench should be used to determine the mounting torque value when installing the sensor. The recommended range is given on the installation drawing. It is wise to replace the seal each time the sensor is reinstalled. 3.1 MOUNTING IN RECESSED PORTS EXISTING Before installing the sensor in previously used mounting ports, clean out residue from previous tests as shown in figure 2. Model 040A Reamer 10-32 MICRO CONNECTOR 5/ 16 HEX 3/ 8-24 THREAD Residue QUARTZ CRYSTALS WELDED DIAPHRAGM Figure 1 The 3/8-24 thread and flush diaphragm design are conventional, providing direct interchangeability with existing machined diaphragm type piezoelectric sensors. The short, rigid element and stiff diaphragm give the 167 Series a 250,000 Hz natural frequency and good linearity even below 1000 psi. Drawing Number 21104 Revision: NR Figure 2 This can be accomplished by hand reaming the 1/4" diameter hole using a PCB Model 040A end-cutting reamer (or equivalent). Should waveform distortion occur during prolonged testing, remove residue as shown. If the seal surface requires machining to clean it after prolonged use, do not forge to deepen the 1/4” diameter hole by the same amount. Otherwise, the sensor may bottom when installed. OPERATION MANUAL FOR Series 167 BALLISTICS PRESSURE SENSOR 3.2 PREPARING NEW MOUNTING PORTS Refer to installation drawing provided in this manual for instructions in mounting hole preparation. For best results, do not deviate from the steps outlined in this drawing. Use good machining practice in preparing the mounting port, paying particular attention to the seal surface (.323 diameter), and keeping it free from tool chatter marks. Note: 3.3 It is important that this surface be perfectly smooth and free from nicks or other discontinuities which might cause leaks at high pressures. The passage behaves like an underdamped second order system, the resonant frequency being determined by the passage length. This can have a limiting effect on pressure pulse rise time while causing passage ringing in cases where the passage is too long. The following relationship determines this resonant frequency (fr): fr v 4L Hz (EQ. 1) Where: fr = Resonant frequency of passage (Hz) v = Velocity of sound in air (ft/sec) RECESSED MOUNT The recessed installation is shown in figure 3. This type of mounting protects the sensor diaphragm from the effects of high-flash temperatures and particle impingement due to blast effects, thereby prolonging sensor life. 2 L = Length of column (ft) For air at room temperature, (EQ.1) becomes: fr 3300 L (EQ. 2) Where: L = Passage length (in.) The natural frequency and approximate fastest pressure step rise time for various length passages is shown in the following chart (Medium, air at 25C): .010 min. Figure 3 The recommended range of passage diameters is .090 to .125 diameter. The limitation in this type of installation lies in the frequency-limiting effects of the passage, due to its length. Drawing Number 21104 Revision: NR PASSAGE LENGTH (in.) .050 .100 .200 .50 1.0 PASSAGE RESONANCE (kHz) 66 33 16.5 6.6 3.3 APPROX. FASTEST RISE TIME (uSec) 5 10 20 50 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values due to variations in the velocity of sound in air caused by changes in temperature and pressure of the air in the passage. OPERATION MANUAL FOR Series 167 BALLISTICS PRESSURE SENSOR If possible, keep passage lengths below .10 inches for best results in most ballistic applications, especially at casemouth and when measuring port pressures. For best matching of passage to diaphragm, maintain the .010 clearance ahead of the diaphragm as shown in previous figure. 3.4 FLUSH MOUNT In the flush mount installation, there is no reduced area passage from the sensor diaphragm to the test chamber; rather, the sensor diaphragm is mounted flush with (or slightly recessed from) the inside surface of the test chamber. Use this type of installation only if space or rise time considerations preclude the use of the recessed installation. In severe pyrotechnic environments, sensor life may be severely limited with flush installation. For flush mount installations, a silicone rubber coating approximately .010” thick can be effective. General Electric RTV type 106 silicon rubber is recommended. It is best to recess the diaphragm .010” for this type of protection. 3.6 Use only low-noise treated coaxial cable (PCB Model 003A or equivalent) to connect sensor to the charge amplifier, in-line voltage amplifier, or other high input impedance readout instrument. Protect the ultra-high impedance connection against moisture contamination with shrink tubing or other suitable means. The two following figures illustrate typical circuit connections. It is good practice to support sensor cables by tying them to rigid structures to prevent excessive motion which can generate noise and materially shorten cable life. Allow adequate strain relief loop. 4.0 3.5 FLASH TEMPERATURE EFFECTS Although the 167 Series has better thermal characteristics than the 118B due to its welded diaphragm, additional precautions may be taken, if required, against flash temperature effects. Some of these measures can include filling the recessed passage with silicone grease (DC-4 or equivalent). The application of several layers of black vinyl electrical tape directly on the diaphragm has proven effective in many cases. Flash temperature effects are usually longer term and will show up as baseline shift, long after the event to be measured has passed. INSTALLING CABLES CALIBRATION These sensors can be calibrated using static hydraulic techniques such as by dead weight testers or, by comparison, with a static pressure sensor coupled with a readout device. Use charge amplifier on "long time constant" and allow sensor to thermally stabilize before attempting to calibrate. Note: Do not attempt to use a charge amplifier which has less than a 5000 second time constant in the "long TC" position. Several charge amplifiers are designed especially for use with ceramic accelerometers for higher frequency measurements. In general, these types are not suitable for calibration of quartz pressure sensors by quasi-static means. A factory charge calibration is supplied with each sensor. Factory recalibration is available at a nominal charge. Drawing Number 21104 Revision: NR 3 OPERATION MANUAL FOR Series 167 BALLISTICS PRESSURE SENSOR 5.0 4 OPERATION Model 003A05 Cable Model 167A In-Line Charge Amplifier Most test set-ups will include the sensor working into an electrostatic charge amplifier such as the PCB Model 462A. ICP Power Unit Note: Keep the input cable to the charge amplifier as short as practical as electrical noise at the output of any charge amplifier is directly related to input cable length (capacitance). Depress ground button of charge amplifier and adjust electrical zero if necessary. Readout Model 070A02 Adaptor Model 012A03 Cable Range the amplifier as desired to give the necessary full-scale voltage. Figure 5: Typical Circuit Connection with In-Line Voltage or Charge Amplifier For normal, drift-free operation, switch charge amplifier time constant selector to "medium" or "short" during use. 6.0 5.1 POLARITY Since most charge amplifiers are inverting amplifiers, the 167 Series is designed to produce a negativegoing charge for increasing pressure at the diaphragm. Special positive output versions are available for use with non-inverting ICP source follower amplifiers. (Models 401A and 402A.) Specify P167 Series to order the positive polarity model. Model 167A Cable Model 003A05 Model 070A02 Adaptor Readout Charge Amplifier Model 012A03 Cable Figure 4: Typical Circuit Connection with Laboratory- Type Charge Amplifier Drawing Number 21104 Revision: NR MAINTENANCE The only maintenance required on the 167 Series is the cleaning of the connector to restore insulation resistance. At times during use in damp environments or after period of storage, the insulation resistance of these sensors may degrade (1012 ohms is normal). To restore insulation, wipe connector end with clean cloth or paper towel dipped in trichlor alcohol or equivalent solvent and bake sensor in 250 F oven for several hours. A vacuum oven, if available, will hasten the process. 7.0 INSTALLATION FOR USE IN SHOTSHELL TESTING When the 167 Series is to be used for ballistics testing of shotshell ammunition, the sensor must be positioned such that the diaphragm is as close to perfectly flush with the chamber I.D. as possible (See figure 6). Prepare the mounting port as shown in Installation Drawing No. 167-1010-91 or 1751. The approved SAAMI location is 1.000 inches forward of the boltface, intersecting the C/L of the barrel. OPERATION MANUAL FOR Series 167 BALLISTICS PRESSURE SENSOR 5 As shown in figure 7, it is essential that the diaphragm surface and the inner diameter of the chamber be perfectly tangent. To facilitate this adjustment, a set of spacer washers (Model 065A19) of various thickness is supplied with each model of the 167 Series to be used for this application. By trial and error, it is a simple matter to select the proper thickness spacer for each installation. Note: Frequent removal and reinstallation may result in a permanent "squeezing" deformation of the spacer washer, especially if excessive torque is used during the installation. This deformation may allow the sensor diaphragm to enter the chamber too deeply. It is important that the sensor not be overtorqued. If possible, always measure this mounting torque so as to prolong sensor and seal life, as well as to maintain accuracy of calibration. TANGENT Figure 7: Shotshell Ammunition The proper mounting torque is specified on the installation drawing. 1.000 Drilled Cartridge Location Cartridge Test Barrel Figure 6 ICP is a registered trademark of PCB Piezotronics Drawing Number 21104 Revision: NR