2015 Benshaw Product Catalog

advertisement
2015 Fall Product Catalog
ADVANCED CONTROLS & DRIVES
A Regal Brand
24/7/365
Service and Support
Field Services:
Maintenance Services:
• Installations and commissioning
• Thermography
• On-site repairs
• Service contracts
–– Scheduled / emergency
• On-site retrofits and upgrades
Factory Services:
• Send-in repair
–– Scheduled / emergency
• Send-in retrofits and upgrades
• Quick ship modified — Benshaw
Express stock
• Benshaw and 3rd party
Technical Training:
• In-class in our training center
• In-class at your facility
• Preventive
–– Maintenance / agreements
• Power quality
Spare Parts:
• 24 / 7 / 365 availability
• Emergency delivery
–– Courier available
• Replace or repair
Technology Retrofits:
• Solid state motor controls and drives
• Electromechanical motor controls
• Customized for your business
benshaw.com
Return to the
Table of Contents
Medium Voltage Variable
Frequency Drives
...................................................... Section 1
Low Voltage Variable
Frequency Drives
...................................................... Section 2
Medium Voltage Starters
...................................................... Section 3
Low Voltage Starters
...................................................... Section 4
Wye Delta Starters
...................................................... Section 5
Pump Control Starters
...................................................... Section 6
Return to the
Table of Contents
benshaw.com
Return to the
Table of Contents
Medium Voltage Variable
Frequency Drives
Engineered Medium Voltage
Drive Products
M2L 3000 Series..................................1-2
Return to the
Table of Contents
1-1
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series
2.3–11 kV Class, 300–90,000 HP
Product Highlights:
With over 30 years of medium voltage motor controls experience, Benshaw is now
introducing a new family of medium voltage drives. Our medium voltage drive features
a unique technology that allows Benshaw to offer a simple, compact and reliable drive
solution. Our innovative topology, coupled with an advanced control architecture, will
enable customers to transform the way they do business.
Developed, designed and
manufactured in the USA.
Supported around the globe.
The M2L 3000 Medium Voltage Variable Frequency Drive is a step change in motor
control power technology. Though designed for industrial applications, it benefits
from Benshaw’s wide-ranging experience in defense and nuclear-related technologies,
an arena where products must meet the most rigorous standards and where failure is
simply not an option.
Our innovative patented topology — modular multilevel converter (M2LC) — is powered
by state-of-the-art hardware and software controls. Our control algorithms are setting
the stage for the next generation of VFDs.
Key Features:
• Compact Modular Design
–– Simplistic component arrangement with minimal total part count
• Installation Flexibility
–– Optimal for retrofits
• Arc Resistant
–– Safety by design—arc flash footprint inherently lower
• Energy Efficiency
–– Inverter efficiency ≥99.5%
• Robust Control Architecture
–– High performance, reliability and immunity from EMI through noise-tolerant
signaling and fiber optic communications
1-2
benshaw.com
benshaw.com
Return to the
Table of Contents
Variable Frequency Drives
M2L 3000 Series
M2L Topology
Power is fed to the M2L inverter from a standard, easily sourced isolation transformer, which
can be placed in a remote or outdoor location. All M2L drive systems are compliant with
IEEE519-1992 input harmonic current requirements through the use of an 18-pulse input
transformer (standard).
+ BUS
-20
CELL
A2
CELL
B2
CELL
C2
CELL
A4
CELL
B4
CELL
C4
CELL
A6
CELL
B6
CELL
C6
T1
L1
T2
L2
AC MOTOR
0
T3
L3
20
CELL
A5
CELL
B5
CELL
C5
CELL
A3
CELL
B3
CELL
C3
CELL
A1
CELL
B1
CELL
C1
GND
- BUS
M2L Topology
Return to the
Table of Contents
1-3
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series
M2L Topology
Energy storage is distributed among identical power modules that comprise the M2LC inverter,
which greatly reduces arc flash potential and substantially improves reliability.
CELL CONTROL &
POWER SUPPLY BOARD
Cell detail
Each cell in the inverter contains two fourth-generation IGBT switching modules and uses only
high-reliability dry-type film capacitors. Embedded circuitry in each cell provides intelligence
for control and communication.
1-4
benshaw.com
Return to the
Table of Contents
Variable Frequency Drives
M2L 3000 Series
Advanced Features and Configurations
Benshaw provides an integrated synchronous transfer scheme using the M2L drive and an
intelligent PLC control center. Synchronous, or “bi-directional bumpless,” transfer allows a
single inverter to start up to six individual motors and smoothly transfer them to across-theline operation.
INCOMING
POWER
VFD OUTPUT
DISCONNECT
(OPTIONAL)
VFD INPUT
CONTACTOR
DECOUPLING
REACTOR
DISCONNECT
(OPTIONAL)
LINE
ISOLATION
CONTACTOR
VFD
ISOLATION
CONTACTOR
LINE
DISCONNECT
MV FUSE
LINE
DISCONNECT
MV FUSE
MV FUSE
MV FUSE
LINE
DISCONNECT
MV FUSE
LINE
DISCONNECT
VFD INPUT
DISCONNECT
DISCONNECT
(OPTIONAL)
LINE
ISOLATION
CONTACTOR
VFD
ISOLATION
CONTACTOR
DISCONNECT
(OPTIONAL)
LINE
ISOLATION
CONTACTOR
VFD
ISOLATION
CONTACTOR
DISCONNECT
(OPTIONAL)
LINE
ISOLATION
CONTACTOR
VFD
ISOLATION
CONTACTOR
3 CONDUCTORS
(MIN)
M2L SERIES
INVERTER
2 CONDUCTORS
(MIN)
INDUCTION
MOTOR #1
INDUCTION
MOTOR #2
INDUCTION
MOTOR #3
INDUCTION
MOTOR #4
M2L SERIES
CONVERTER
3 CONDUCTORS
(MIN)
Single-line diagram of a typical four-motor synchronous transfer scheme
Return to the
Table of Contents
1-5
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series
Advanced Features and Configurations
High speed communication architecture enables the connection of up to eight inverter sections
in parallel, providing clean, multi-level PWM output for motors up to 90,000 HP.
DC LINK
REACTOR
INVERTER
SECTION
AC
REACTOR
MASTER
INCOMING
POWER
XFMR/RECTIFIER
(CONVERTER)
ASSEMBLY
STD-EE
DC LINK
REACTOR
TC-OF
INVERTER
SECTION
STD-EE
PROCESS
CONTROL
INTERFACE
STD-EE
HMI
AC
REACTOR
FOLLOWER
STD-EE: STANDARD ELECTRICAL ETHERNET
ROUTER
STD-EE
INDUCTION
MOTOR
TC-OF: TIME CRITICAL OPTICAL FIBER
LAPTOP
(BENSHAW
CONNECT)
SINGLE MACHINE INTERFACE
Example of two parallel inverter sections
Contact your regional sales manager for more information and to obtain a quote.
1-6
benshaw.com
Return to the
Table of Contents
Low Voltage Variable
Frequency Drives
Standard Low Voltage Drive Products
General Purpose Micro Drives............2-2
Sensorless Vector Drives.....................2-5
NEMA 4X Washdown / NEMA 12
Sensorless Vector Drives...................2-10
Built-to-Order Packaged Drives........2-14
Standard Low Voltage Drive Options
Input Line Reactors...........................2-19
Output Reactors................................2-25
Long Lead Filters.............................. 2-27
Dynamic Brake Resistors
and Brake Modules...........................2-30
Engineered Low Voltage Drive Products
VFD Pre-Order Check List.................2-32
Sensorless Vector Drives...................2-35
Integrated Control Solutions.............2-52
Custom-Engineered
Drive Solutions..................................2-54
Clean Power Drives...........................2-55
Return to the
Table of Contents
2-1
Standard Low Voltage
Drive Products
General Purpose Micro Drives
GX Series
RATINGS
Constant Torque:
1–5 HP @ 460 V
1–5 HP @ 230 V
*Chassis VFD converts to
NEMA 1 with conduit kit
1–5 HP, 230 / 460 V / Protected Chassis / NEMA 1*
Product Highlights:
The GX series is a compact, economical chassis drive designed
for low horsepower applications.
The GX series has a powerful set of parameters with a simple, easy to use keypad.
The programming structure provides quick, simple setup.
Although small in size, the GX series provides a large amount of digital I/O
for custom applications.
Key Advantages:
• Small, compact design
• Constant torque rated
• Sensorless vector control or V/Hz control
• Standard dynamic braking transistor (external resistor required)
• Flexible, programmable I/O
• Integral PID control
• Standard ModBus RTU terminals
• Windows based software
Standard Features:
• Standard I/O: 8 digital inputs, 2 analog inputs, 1 analog output, 1 relay output,
1 open collector output
• Digital metering: Output current, output frequency, DC link voltage, motor RPM,
output power, output voltage, output torque
• Protection: Over current, ground fault, over voltage, current limit, motor overload,
output phase loss, over heat, loss of signal and more
• Communications: ModBus RTU (standard)
• Voltage tolerance: ±10%
• Control methods: Open loop V / Hz, sensorless vector control
• V / Hz patterns: Linear, squared, user programmable V / Hz
• Analog output functions: 1 analog output 0 – 10 VDC: Configurable to motor
speed, output current, output voltage, DC link voltage
• Analog inputs: 1 at 0/4 – 20 mA, 1 at 0 – 10 VDC
• Relay output and open collector output: 1 Form C relay output and 1 open
collector output, programmable to running, faulted, stopped, ready, at speed,
high or low frequency levels, loss of signal and more
• Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire
start / stop, reset, jog, preset speeds, motorized pot function, external trip,
alternate ramp selections, HOA and more
• User interface: 4 digit LED display
• Stop methods: Coast, decel, DC injection braking and optional dynamic braking
2-2
benshaw.com
Return to the
Table of Contents
General Purpose Micro Drives
GX Series
Control Terminal Layout
LED
display
Status
indicators
Run / stop
buttons
Left / right up /
down keys
Save
parameters
Programmable
I/O
Modbus
terminal
T/M
Description
MO
MG
24
P1
P2
CM
P3
P4
P5
CM
P6
P7
P8
VR
V1
I
AM
3A
3B
3C
S+
S–
Multi-Function Open Collector Output
MO Common
24 V Power Supply (100 mA Max.)
Multi-Function Input Terminal (Factory Setting)
Fx: Forward Run
Rx: Reverse Run
Input Signal Common
Multi-Function Input Terminal (Factory Setting)
Bx: Emergency Stop
Rst: Trip Reset
Jog: Jog Operation
Input Signal Common
Multi-Function Input Terminal (Factory Setting)
Multi-Step Freq. — Low
Multi-Step Freq. — Middle
Multi-Step Freq. — High
10 V Power Supply For Potentiometer
Freq. Setting Voltage Signal Input: -0 – 10 V
Freq. Setting Current Signal Input: 0 – 20 MA
Multi-Function Analog Output Signal: 0 – 10 V
Multi-Function Relay Output Terminal
Normally Open Contact
Normally Closed Contact
Common
RS485 Communication Terminal
Return to the
Table of Contents
2-3
Standard Low Voltage
Drive Products
General Purpose Micro Drives
GX Series
Protected Chassis, 1–5 HP, 230 / 460 V
230 V
Constant Torque
Model Number
Dimensions (in.)
HP
Amps
H
W
D
Weight (lbs.)
 RSI-001-GX-2B •
1
4.2
5
2.8
5.1
2
List Price
$500.00
 RSI-002-GX-2B •
2
6.8
5
3.9
5.1
3
$600.00
 RSI-003-GX-2B •
3
9.6
5
5.5
6.1
4
$700.00
 RSI-005-GX-2B •
5
15.2
5
5.5
6.1
5
$800.00
460 V
Constant Torque
Model Number
Dimensions (in.)
HP
Amps
H
W
D
Weight (lbs.)
List Price
 RSI-001-GX-4B •
1
2.1
5
2.8
5.1
2
$600.00
 RSI-002-GX-4B •
2
3.4
5
3.9
5.1
3
$700.00
 RSI-003-GX-4B •
3
4.8
5
5.5
6.1
4
$750.00
 RSI-005-GX-4B •
5
7.6
5
5.5
6.1
5
$900.00
NEMA 1 Conduit Kits
Model Number
Description
 GX-NEMA1KIT-A
Conduit Kit for 1 HP GX Drive
List Price
$60.00
 GX-NEMA1KIT-B
Conduit Kit for 2 HP GX Drive
$60.00
 GX-NEMA1KIT-C
Conduit Kit for 3 HP and 5 HP GX Drive
$60.00
Remote Keypad
Model Number
Description
 VFD-2M-GX-KEYPAD
Remote Mount Keypad and 2 Meter Cable
List Price
$175.00
• Units are stocked as protected chassis. If NEMA 1 enclosed is required, add NEMA 1 conduit kit.
Conduit kits will need to be installed by customer.

Web stocked
Available for same day shipping.
2-4
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
SG Series
RATINGS
Variable Torque:
7.5–40 HP @ 230 V
7.5–700 HP @ 460 V
7.5–400 HP @ 600 V
Standard Duty:
7.5–40 HP @ 230 V
7.5–600 HP @ 460 V
7.5–400 HP @ 600 V
Variable Torque / Standard Duty / Heavy Duty
Product Highlights:
The SG series is a compact, economical drive designed for the most demanding applications.
The flexible power stack allows the user to apply it to heavy duty loads (150% for 60 secs),
standard duty loads (120% for 60 secs), or variable torque loads (110% for 60 secs).
With over 250 programmable parameters, Benshaw’s SG series drives are configurable
to meet the needs of almost any industrial application, yet remain simple and easy to use.
Key Advantages:
• Standard and heavy duty ratings
• Integral PID Control
• Communications: Modbus RTU
(standard); Optional Fieldbus includes
DeviceNet, Profibus, BacNet, LonWorks,
Modbus TCP
• Sensorless vector control or V/Hz control
• Voltage tolerance: -15%, +10%
• Integral multiple motor control
• Control methods: V/Hz, sensorless
for pumping applications
• Uploadable / downloadable keypad
Heavy Duty:
• Flexible, programmable I/O
5–30 HP @ 230 V
5–500 HP @ 460 V
5–300 HP @ 600 V
• Economical, compact design
• Simple, easy to use LCD interface
• Standard ModBus RTU port
• Windows-based software
Standard Features:
• Standard I/O: 8 digital inputs,
2 analog inputs, 2 analog outputs,
5 relay outputs
• Optional I/O: Isolated analog output
board (adds 2 additional analog outputs,
0/4 – 20 mA)
• Digital metering: Output currents,
ground current, output frequency, DC
link voltage, motor RPM, output motor
voltage, run time and more
• Protection: Over current, ground
fault, over voltage, current limit, motor
overload, phase loss, over heat, loss of
signal and more
vector, slip compensation
• V/Hz patterns: Linear, squared,
user programmable V/Hz
• Analog outputs: 2 at 0 – 10 VDC
(standard), 2 at 0/4 – 20 mA (with option
board). Configurable to motor speed,
output current, output voltage, DC link
voltage, power, PID follower
• Relay outputs: 1 Form C fault relay
output, 4 Form A relay outputs
configurable to running, faulted, ready,
at speed, high or low frequency levels,
loss of signal, ready and more
• Digital inputs: 8 digital inputs
configurable to forward run, reverse
run, 3 wire start / stop, reset, jog, preset
speeds, motorized pot function, external
trip, alternate ramp selections, HOA
and more
• User interface: 2 line LCD display,
16 characters per line
• Stop methods: Coast, decel, DC injection
braking, Flux braking and optional
dynamic braking
• Analog inputs: 1 at 0/4 – 20 mA,
1 at 0 – 10 VDC (or -10 to 10 VDC)
Return to the
Table of Contents
2-5
Standard Low Voltage
Drive Products
Sensorless Vector Drives
SG Series
Basic Wiring Diagram
DB UNIT
(option)
MCCB1
MC1
ACR
R
S
T
G
3 Phase
AC input
P1P2
24 VDC (50mA max)
24
Default: Speed-L
M1
Default: Speed-M
M2
Default: Speed-H
M3
Default: RST
M4
BX (E-STOP)
M5
Default: JOG
M6
Default: FX
M7
Default: RX
M8
CM
24G
CN1
Sourcing
24G Mode PNP
Sinking
24P Mode NPN
Motor
E
Safety stop
(600V only)
V1
0[V]~+12[V]
Analog
input
0/4[mA]~20[mA]
5G
24V 4.9mA
S0
Default: Frequency
Analog meter
S1
Default: Voltage
Max output
voltage:12V
Source max: 30mA
Sink max: 20mA
5G
3A
3C
3B
A2
C2
Aux. relays
A3
Fault relay output
250Vac, 1A
24G
C3
A0
A4
B0
C4
Pulse input method: (A+B), (A)
Input freq: 0Hz~100KHz
Terminating
resistor
C-
Pulse
input
5G
24G
NT
C+
24G
benshaw.com
M
W
I
A1
2-6
V
V1S -12[V]~+12[V]
C1
RS-485
U
U
V
W
E/G
RSi-SG
Setting
Switch
Relay outputs
programmable
250Vac, 1A
N
5G
Motor thermal
detection
Return to the
Table of Contents
Sensorless Vector Drives
SG Series
NEMA 1
230 V
Variable Torque
Model Number
HP
 RSI-007-SG-2B
 RSI-010-SG-2B
Standard Duty
Heavy Duty
Dimensions (in.)
HP
Amps
H
W
D
Weight
(lbs.)
List Price
22
5
17
11.2
5.9
6.2
11
$1,400.00
29
7.5
23
11.2
7.9
7.2
14
$1,600.00
15
42
10
33
11.2
7.9
7.2
14
$1,750.00
20
55
15
44
17.9
9.8
7.9
28
$2,285.00
25
67
20
54
17.9
9.8
7.9
29
$2,985.00
30
80
25
68
23.6
12
9.2
44
$3,500.00
40
105
30
84
23.6
12
9.2
44
$4,125.00
Amps
HP
Amps
7.5
24
7.5
10
32
10
 RSI-015-SG-2B
15
46
 RSI-020-SG-2B
20
60
 RSI-025-SG-2B
25
74
 RSI-030-SG-2B
30
88
 RSI-040-SG-2B
40
115
460 V
Variable Torque
Standard Duty
Heavy Duty
Dimensions (in.)
Model Number
HP
Amps
HP
Amps
HP
Amps
H
W
D
Weight
(lbs.)
List Price
 RSI-007-SG-4B
7.5
12
7.5
11
5
8
11.2
5.9
6.2
11
$1,425.00
 RSI-010-SG-4B
10
16
10
14
7.5
11
11.2
7.9
7.2
14
$1,725.00
 RSI-015-SG-4B
15
24
15
22
10
17
11.2
7.9
7.2
14
$1,885.00
 RSI-020-SG-4B
20
30
20
27
15
22
17.9
9.8
7.9
28
$2,450.00
 RSI-025-SG-4B
25
39
25
35
20
28
17.9
9.8
7.9
29
$2,800.00
 RSI-030-SG-4B
30
45
30
41
25
34
23.6
12
9.2
44
$3,545.00
 RSI-040-SG-4B
40
61
40
55
30
44
23.6
12
9.2
44
$4,250.00
 RSI-050-SG-4B
50
75
50
68
40
55
25.3
12.1
10.5
60
$5,225.00
 RSI-060-SG-4B
60
91
60
83
50
66
25.3
12.1
10.5
60
$6,500.00
 RSI-075-SG-4B
75
110
75
100
60
80
25.3
12.1
11.2
64
$7,500.00
 RSI-100-SG-4B
100
152
100
139
75
111
30.2
14.5
12.1
95
$9,000.00
 RSI-125-SG-4B
125
183
125
167
100
134
30.2
14.5
12.1
95
$11,000.00
 RSI-150-SG-4 • *
150
223
150
204
125
164
30.9
20.1
16.6
225
$13,000.00
 RSI-200-SG-4 • *
200
264
200
242
150
194
30.9
20.1
16.6
225
$15,500.00
 RSI-250-SG-4 • *
250
325
250
302
200
240
33.9
20.1
16.6
255
$18,000.00
 RSI-350-SG-4 • *
350
432
300
396
250
317
42.5
27.2
17.3
450
$23,000.00
 RSI-400-SG-4 • *
400
547
400
501
300
401
42.5
27.2
17.3
450
$32,000.00
 RSI-500-SG-4 •
500
613
450
562
350
450
44.9
30.8
17.4
540
$40,000.00
 RSI-600-SG-4 •
600
731
500
670
400
536
51.3
36.3
19.5
840
$48,000.00
 RSI-700-SG-4 •
700
877
600
804
500
643
51.3
36.3
19.5
840
$57,750.00
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute
Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units.
• Protected chassis only (power terminal covers do not meet NEMA 1).
* DC Link Reactor (internal)

Web stocked
Available for same day shipping.
Return to the
Table of Contents
2-7
Standard Low Voltage
Drive Products
Sensorless Vector Drives
SG Series
NEMA 1 / Protected Chassis
600 V
Variable Torque
Standard Duty
Heavy Duty
Dimensions (in.)
HP
Amps
H
W
D
Weight
(lbs.)
List Price
8.2
5
6.6
14
7.9
7.2
15
$1,650.00
11
7.5
9
14
7.9
7.2
16
$1,725.00
15
15.5
10
12
14
7.9
7.2
16
$1,885.00
20
21
15
17
17.9
9.8
7.9
28
$2,450.00
27
25
24.7
20
19.8
17.9
9.8
7.9
29
$2,800.00
34
30
31
25
25
23.6
12
9.2
44
$3,545.00
40
43
40
39
30
31.5
23.6
12
9.2
44
$4,250.00
 RSI-050-SG-6B
50
55
50
50
40
43
25.3
11.8
11.5
71
$5,225.00
 RSI-060-SG-6B
60
64
60
58.6
50
55
25.3
11.8
11.5
71
$6,750.00
Model Number
HP
Amps
HP
Amps
 RSI-007-SG-6B
 RSI-010-SG-6B
7.5
9
7.5
10
12
10
 RSI-015-SG-6B
15
17
 RSI-020-SG-6B
20
23
 RSI-025-SG-6B
25
 RSI-030-SG-6B
30
 RSI-040-SG-6B
 RSI-075-SG-6B
75
80
75
73
60
64
25.3
11.8
11.5
71
$7,850.00
 RSI-100-SG-6B
100
104
100
95
75
80
30.2
14.6
13.3
102
$9,125.00
 RSI-125-SG-6B
125
128
125
117
100
104
30.2
14.6
13.3
102
$11,125.00
 RSI-150-SG-6 • *
150
150
150
137
125
128
30.9
20
16.6
225
$13,100.00
 RSI-200-SG-6 • *
200
200
200
184
150
147
33.9
20
16.6
255
$16,250.00
 RSI-250-SG-6 • *
250
242
250
222
150
177
33.9
20
16.6
255
$21,000.00
 RSI-350-SG-6 • *
350
333
300
305
250
244
42.5
27.2
17.7
450
$23,785.00
 RSI-400-SG-6 • *
400
424
400
389
300
311
42.5
27.2
17.7
450
$32,845.00
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute
Units ending in a “B” designate NEMA 1. Units not ending in a “B” are protected chassis units.
• Protected chassis only (power terminal covers do not meet NEMA 1).
* DC Link Reactor

Web stocked
2-8
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
SG Series
Options
Dynamic Brake Transistor Modules
Model Number
Description
List Price
VFD-RSI-DBU-020-2
230V Dynamic Braking Transistor for 1 – 20 HP VFD, 10% Duty Cycle
$1,100.00
VFD-RSI-DBU-030-2
230V Dynamic Braking Transistor for 25 – 30 HP VFD, 10% Duty Cycle
$1,200.00
VFD-RSI-DBU-050-2
230V Dynamic Braking Transistor for 40 – 50 HP VFD, 10% Duty Cycle
$1,300.00
VFD-RSI-DBU-020-4
460V Dynamic Braking Transistor for 1 – 20 HP VFD, 10% Duty Cycle
$1,100.00
VFD-RSI-DBU-030-4
460V Dynamic Braking Transistor for 25 – 30 HP VFD, 10% Duty Cycle
$1,200.00
VFD-RSI-DBU-050-4
460V Dynamic Braking Transistor for 40 – 50 HP VFD, 10% Duty Cycle
$1,300.00
VFD-RSI-DBU-075-4
460V Dynamic Braking Transistor for 60 – 75 HP VFD, 10% Duty Cycle
$1,600.00
VFD-RSI-DBU-100-4
460V Dynamic Braking Transistor for 100 HP VFD, 10% Duty Cycle
$1,700.00
For HP greater than 100 HP or duty cycle greater than 10%, consult factory.
Fieldbus Communication Cards
Model Number
Description
PC-400001-00
DeviceNet Communication Board Kit, SG VFD
List Price
$575.00
PC-400002-00
Profibus Communication Board Kit, SG VFD
$885.00
PC-400003-00
LonWorks Communication Board Kit, SG VFD
$1,000.00
PC-400004-00
BacNet Communication Board Kit, SG VFD
$1,325.00
PC-400005-00
Ethernet IP/Modbus TCP Communication Board Kit, SG VFD
$1,100.00
Display / Keypad Remote Mounting
Model Number
Description
LCD-100000-00
Replacement Display / Keypad
List Price
$200.00
VFD-2M-RE-CABLE-SG
2 Meter Keypad Cable
$110.00
VFD-3M-RE-CABLE-SG
3 Meter Keypad Cable
$135.00
VFD-5M-RE-CABLE-SG
5 Meter Keypad Cable
$145.00
VFD-KEYPAD-SG-BEZEL
Bezel, for SG Keypad, Remote Mounting
$20.00
VFD-KEYPAD-SG-BLANK
Keypad Blank, Installs in Drive when Keypad Is Remote
$20.00
Analog Output Card
Model Number
Description
VFD-RSI-SG-4-20-MA
4–20 mA Output Card, Adds (2) 4–20 mA Outputs
Return to the
Table of Contents
List Price
$725.00
2-9
Standard Low Voltage
Drive Products
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
RATINGS
Constant Torque:
1 HP @ 115 V
1 to 20 HP @ 230 V
1 to 200 HP@ 460 V / 600 V
Standard Duty / Heavy Duty
RSI S4 Series Product Highlights:
The S4 Series is a line of high performance NEMA 4X washdown variable frequency
drives. Benshaw’s S4 variable frequency drives are built to withstand the harshest
environments and hold up under your most demanding pressure washing applications.
All S4 Series drives combine a simple user interface with an array of features and are
suited to almost any indoor environment.
S4 variable frequency drives come standard with over 180 configurable parameters
to match specific application and interface requirements. A standard dynamic braking
transistor and resistor are also included for regenerative applications.
Key Advantages:
• NEMA 4X washdown duty enclosure
• Sensorless vector control
• Standard braking transistor and resistor
• Infrared programming port
• Standard and Heavy Duty ratings
• LCD plain English display
• Simple, easy-to-use interface
• Standard ModBus communication port
• Integral Pl control
Standard Features:
• NEMA 4X washdown enclosure
• Standard l/O: 10 digital inputs, 2 analog inputs, 2 analog outputs, 2 relay outputs
• Digital metering: Output current, output volts, power, MWh meter, run time,
power on time, bus voltage, output frequency
• Communications: ModBus standard, optional other Fieldbus
• Voltage tolerance: ±10%
• Sensorless vector control
• V / Hz Pattern: Linear, quadratic
• Analog output functions: Output voltage, output current, drive load, drive temp,
stator frequency, output power
• Analog inputs: 0–10VDC, 4–20mA, -10VDC to 10VDC, pulse train input
• Relay outputs: Running, forward, reverse, ready, faulted, at speed, keypad
control, adjustable torque levels, adjustable current levels, PID limits, loss of
reference, timers
• 10 digital inputs configurable: Run, preset speeds, jogging, PID disable,
fault reset, drive enable, timers, motorized pot
• User interface: 20 character LCD display, infrared programming port
• Braking functions: Decal, coast, DC injection, dynamic braking
• Units 1–100HP are NEMA 4X; units 125–200HP are NEMA 12
2-10
benshaw.com
Return to the
Table of Contents
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
Basic Wiring Diagram
+24 VDC
+24
NC2
Forward Run
FWD
RC2
Reverse Run
REV
NO2
Jog
R/J
NC1
Digital Input #1
DI1
RC1
Digital Input #2
DI2
NO1
Digital Input #3
DI3
DO1
Digital Output #1
Digital Input #4
DI4
DO2
Digital Output #2
Digital Input #5
DI5
DOQ
Pulse Train Output
MOL
dcom
Common
EN
dcom
Common
dcom
Imet
4–20 mA output
cin+
acom
Analog Common
cin-
Vmet
0–10 VDC Output
+10
acom
Analog Common
External Fault
Enable
Relay #2
Relay #1
4–20 mA input
0–10 VDC Input
Vin1
acom
0 – 10 VDC Input
Return to the
Table of Contents
Vin2
2-11
Standard Low Voltage
Drive Products
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
NEMA 4X / 230 V
Model Number
 RSI-001-S4-2W
Standard Duty
HP
Amps
1
4.2
Heavy Duty
HP
Amps
0.5
2.5
H
9.5
Dimensions (in.)
W
6.5
D
6.1
Weight
(lbs.)
9
$1,685.00
List Price
 RSI-002-S4-2W
2
6.8
1
4.8
9.5
6.5
6.1
9
$1,700.00
 RSI-003-S4-2W
3
9.6
2
7.8
9.5
6.5
8.5
9
$1,750.00
 RSI-005-S4-2W
5
15.2
3
11
12
8.7
6.5
14
$2,050.00
 RSI-007-S4-2W
7.5
22
5
17.5
12
8.7
6.5
14
$2,150.00
 RSI-010-S4-2W
10
28
7.5
25.3
17.4
10.8
7.9
30
$3,650.00
 RSI-015-S4-2W
15
42
10
37.2
17.4
10.8
7.9
30
$3,950.00
 RSI-020-S4-2W
20
54
15
48.3
20.2
11.3
11.7
50
$5,895.00
 RSI-025-S4-2W
25
68
20
62.1
20.2
11.3
11.7
50
$6,500.00
Heavy Duty
HP
Amps
0.5
2.5
H
9.5
Dimensions (in.)
W
6.5
D
6.1
Weight (lbs.)
9
List Price
Heavy Duty
HP
Amps
0.5
1.1
H
9.5
Dimensions (in.)
W
6.5
D
6.1
Weight (lbs.)
9
$1,650.00
110 V Input / 230 V Output
Model Number
 RSI-001-S4-1SW •
Standard Duty
HP
Amps
1
4.2
$1,725.00
• Single phase 110 V input / 3 phase 230 V output

Web stocked
NEMA 4X / NEMA 12 / 460 V
Model Number
 RSI-001-S4-4W
Standard Duty
HP
Amps
1
2.1
List Price
 RSI-002-S4-4W
2
3.4
1
2.1
9.5
6.5
6.1
9
$1,700.00
 RSI-003-S4-4W
3
4.8
2
3.4
9.5
6.5
8.5
9
$1,750.00
 RSI-005-S4-4W
5
7.6
3
4.8
12
8.7
6.5
14
$2,200.00
 RSI-007-S4-4W
7.5
11
5
7.6
12
8.7
6.5
14
$2,250.00
 RSI-010-S4-4W
10
14
7.5
11
12
8.7
6.5
14
$2,300.00
 RSI-015-S4-4W
15
21
10
14
17.4
10.8
7.9
30
$3,700.00
 RSI-020-S4-4W
20
27
15
21
17.4
10.8
7.9
30
$4,000.00
 RSI-025-S4-4W
25
34
20
27
17.4
10.8
7.9
30
$4,250.00
 RSI-030-S4-4W
30
40
25
34
17.4
10.8
7.9
30
$4,575.00
 RSI-040-S4-4W
40
52
30
40
20.2
11.3
11.7
50
$7,250.00
 RSI-050-S4-4W
50
65
40
52
20.2
11.3
11.7
50
$7,500.00
 RSI-060-S4-4W
60
77
50
65
29.4
12.9
13.8
110
$12,500.00
 RSI-075-S4-4W
75
96
60
77
29.4
12.9
13.8
110
$13,000.00
 RSI-100-S4-4W
100
124
75
96
29.4
12.9
13.8
110
$15,550.00
 RSI-125-S4-4D *
125
156
100
124
50.5
16.5
18
354
$22,750.00
 RSI-150-S4-4D *
150
180
125
156
50.5
16.5
18
354
$24,750.00
 RSI-200-S4-4D *
200
240
150
180
50.5
16.5
18
354
$25,500.00

Web stocked
* Units ending In “D” are NEMA 12 and not washdown rated.
2-12
benshaw.com
Return to the
Table of Contents
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
NEMA 4X / NEMA 12 / 600 V
Model Number
RSI-001-S4-6W
Standard Duty
HP
Amps
1
1.7
Heavy Duty
HP
Amps
0.5
0.9
H
12
Dimensions (in.)
W
8.7
D
6.5
Weight
(lbs.)
14
$2,000.00
List Price
RSI-002-S4-6W
2
2.7
1
1.7
12
8.7
6.5
14
$2,200.00
RSI-003-S4-6W
3
3.9
2
2.7
12
8.7
6.5
14
$2,250.00
RSI-005-S4-6W
5
6.1
3
3.9
12
8.7
6.5
14
$2,275.00
RSI-007-S4-6W
7.5
9
5
6.1
12
8.7
6.5
14
$2,450.00
RSI-010-S4-6W
10
11
7.5
9
12
8.7
6.5
14
$2,550.00
RSI-015-S4-6W
15
17
10
11
17.4
10.8
7.9
30
$4,250.00
RSI-020-S4-6W
20
22
15
17
17.4
10.8
7.9
30
$4,350.00
RSI-025-S4-6W
25
27
20
22
17.4
10.8
7.9
30
$4,500.00
RSI-030-S4-6W
30
32
25
27
17.4
10.8
7.9
30
$5,200.00
RSI-040-S4-6W
40
41
30
32
20.2
11.3
11.7
50
$7,500.00
RSI-050-S4-6W
50
52
40
41
20.2
11.3
11.7
50
$7,895.00
RSI-060-S4-6W
60
68
50
52
29.4
12.9
13.8
110
$13,500.00
RSI-075-S4-6W
75
82
60
62
29.4
12.9
13.8
110
$13,750.00
RSI-100-S4-6W
100
107
75
77
29.4
12.9
13.8
110
$15,500.00
RSI-125-S4-6D *
125
125
100
99
50.5
16.5
18
354
$23,250.00
RSI-150-S4-6D *
150
144
125
125
50.5
16.5
18
354
$24,500.00
RSI-200-S4-6D *
200
192
150
140
50.5
16.5
18
354
$27,450.00
* Units ending In “D” are NEMA 12 and not washdown rated.
Return to the
Table of Contents
2-13
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series
Standard Duty / Heavy Duty
RATINGS
Standard Duty:
7.5–40 HP @ 230 V
7.5–125 HP @ 460 V
Control
power
transformer
SG Series
sensorless
vector drive
Heavy Duty:
Input circuit
breaker and
disconnect
5–30 HP @ 230 V
5–100 HP @ 460 V
User
terminal
strip
Bypass
contactor
Product Highlights:
Benshaw’s Built-To-Order packaged drives meet UL and CE approvals and are
available with standard (7.5–125 HP) and heavy duty (5–100 HP) ratings to meet
your drive requirements.
Key Advantages:
• Standard and heavy duty ratings
• UL and CE approvals
• Pre-designed options configurable
to your application
Operating Conditions:
• Operating Temperature: -10 to 40°C
• Storage Temperature: -20°C to 65°C
• Humidity: Less than 90% RH max
(non-condensing)
NEMA 12
ventilated
enclosure
• Altitude: 3,300 ft. max.
Standard Features:
• NEMA 12 ventilated enclosure
with fans and filters
• Control power transformer
• User input and output power
connections
• -10° to 40° C operating environment
temperature range
• -20° to 65° C storage temperature
Options:
• Circuit breaker
• Disconnect fused or unfused
• Input line reactor
• Output reactor
• 3 contactor bypass
• Door mounted operator station
(6 configurations)
• SG Series Sensorless Vector Drive
• User terminal strip
• Door mounted keypad
2-14
benshaw.com
Return to the
Table of Contents
Packaged Drives
SGP Series
Part Number Assembler
SGP
005
SG Built-to-Order
Packaged Drives
2
SD
Voltage
NC
A
3B
1
Reactor Options
12
Enclosure
2
=
230 V
A
=
No Reactors
4
=
460 V
B
=
Input Reactor
12
C
=
Output Reactor
D
=
Input and Output Reactor
=
NEMA 12 V
Horsepower
Return to the
Table of Contents
005
=
5 HP
Bypass Type
007
=
7.5 HP
NN
=
None
3B
=
3 Contactor Bypass
010
=
10 HP
015
=
15 HP
020
=
20 HP
025
=
25 HP
030
=
30 HP
040
=
40 HP
050
=
50 HP
060
=
60 HP
075
=
75 HP
125
=
125 HP
Duty Type
Door Mounted Devices
SD
=
120% 1 Min. Std. Duty
1
=
None
HD
=
150% 1 Min. Heavy Duty
2
=
Start / Stop PB, Reset PB,
HOA Switch, Speed POT
3
=
Option 2 Plus Power On,
VFD Running, VFD Fault Light
4
=
Start / Stop PB, Fault Reset
PB, HOA Switch, Speed POT,
Jog PB, Fwd / Rev Switch,
VFD Fault Light
5
=
VFD / Off / Bypass Switch,
Bypass Running Light
6
=
Start / Stop PB, Reset PB,
HOA Switch, Speed POT,
VFD Running Light, VFD /
Off / Bypass Switch, Bypass
Running Light
Disconnect Option
NC
=
Non-Combination
CB
=
Circuit Breaker
FD
=
Fusible Disconnect
CF
=
Non-Fused
Disconnect
IF
=
Inline Fuse
2-15
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series
Standard Duty Rated 120% O/L for 1 Minute
230 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number
HP
A
H
W
D
Weight (lbs.)
List Price
SGP0072SDXXXXXX12
7.5
22
30
24
16
90
$5,275.00
SGP0102SDXXXXXX12
10
28
30
24
16
93
$5,325.00
SGP0152SDXXXXXX12
15
42
36
30
16
99
$5,545.00
SGP0202SDXXXXXX12
20
54
36
30
16
104
$5,995.00
SGP0252SDXXXXXX12
25
68
36
30
16
110
$6,385.00
SGP0302SDXXXXXX12
30
80
36
30
16
148
$6,745.00
SGP0402SDXXXXXX12
40
104
36
30
16
158
$6,825.00
460 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number
HP
A
H
W
D
Weight (lbs.)
List Price
SGP0074SDXXXXXX12
7.5
11
30
24
16
90
$5,295.00
SGP0104SDXXXXXX12
10
14
30
24
16
93
$5,345.00
SGP0154SDXXXXXX12
15
21
30
24
16
99
$5,565.00
SGP0204SDXXXXXX12
20
27
30
24
16
104
$5,965.00
SGP0254SDXXXXXX12
25
34
30
24
16
110
$6,300.00
SGP0304SDXXXXXX12
30
40
36
30
16
148
$6,735.00
SGP0404SDXXXXXX12
40
52
36
30
16
158
$6,825.00
SGP0504SDXXXXXX12
50
65
36
30
16
174
$8,175.00
SGP0604SDXXXXXX12
60
77
36
30
16
174
$9,625.00
SGP0754SDXXXXXX12
75
96
36
30
16
178
$10,525.00
SGP1004SDXXXXXX12 *
100
125
46
30
16
259
$12,425.00
SGP1254SDXXXXXX12 *
125
156
46
30
16
259
$14,355.00
* Dimensions will increase to 70x30x18 for units with three contactor bypass.
Refer to page 2-18 for Disconnect Options, Reactor Options, Bypass Type and Door Mounting Devices
2-16
benshaw.com
Return to the
Table of Contents
Packaged Drives
SGP Series
Heavy Duty Rated 150% O/L for 1 Minute
230 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number
HP
A
H
W
D
Weight (lbs.)
List Price
SGP0052HDXXXXXX12
5
17
30
24
16
90
$5,275.00
SGP0072HDXXXXXX12
7.5
23
30
24
16
90
$5,325.00
SGP0102HDXXXXXX12
10
33
30
24
16
93
$5,545.00
SGP0152HDXXXXXX12
15
44
36
30
16
99
$5,995.00
SGP0202HDXXXXXX12
20
54
36
30
16
104
$6,385.00
SGP0252HDXXXXXX12
25
68
36
30
16
110
$6,745.00
SGP0302HDXXXXXX12
30
84
36
30
16
148
$6,825.00
D
Weight (lbs.)
List Price
460 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number
HP
A
H
W
SGP0054HDXXXXXX12
5
8
30
24
16
90
$5,295.00
SGP0074HDXXXXXX12
7.5
11
30
24
16
90
$5,345.00
SGP0104HDXXXXXX12
10
14
30
24
16
93
$5,565.00
SGP0154HDXXXXXX12
15
21
30
24
16
99
$5,965.00
SGP0204HDXXXXXX12
20
27
30
24
16
104
$6,300.00
SGP0254HDXXXXXX12
25
34
36
30
16
110
$6,735.00
SGP0304HDXXXXXX12
30
40
36
30
16
148
$6,825.00
SGP0404HDXXXXXX12
40
52
36
30
16
158
$8,175.00
SGP0504HDXXXXXX12
50
65
36
30
16
174
$9,625.00
SGP0604HDXXXXXX12
60
77
36
30
16
174
$10,525.00
SGP0754HDXXXXXX12 *
75
96
46
30
16
178
$12,425.00
SGP1004HDXXXXXX12 *
100
125
46
30
16
259
$14,355.00
* Dimensions will increase to 70x30x18 for units with three contactor bypass.
Refer to page 2-18 for Disconnect Options, Reactor Options, Bypass Type and Door Mounting Devices
Return to the
Table of Contents
2-17
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series
Modular Control Options to Customize Your Application
Options
Keypad
Start PB
Stop PB
Reset PB
HOA Switch
Speed POT
Run Light
Fault Light
Power On Light
Jog PB
FWD/REV Switch
VFD/OFF Bypass Switch
Bypass Running Light
List Price
CO1
CO2
CO3
CO4
CO5
CO6
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
$300.00
•
•
$500.00
•
•
•
$125.00
$350.00
$325.00
$550.00
If selecting a unit with bypass, you must select either option 5 or 6.
Door mounted keypad is standard.
230 VAC Drive Adder
HP
CB
N-F Disc
Fsd Disc
Input Fuse
In-React
Out-React
3-Cnt Bypass
5
$400.00
$235.00
$529.00
$200.00
$259.00
$259.00
$545.00
7.5
$400.00
$235.00
$529.00
$165.00
$259.00
$259.00
$545.00
10
$400.00
$235.00
$529.00
$188.00
$301.00
$301.00
$545.00
15
$450.00
$235.00
$659.00
$214.00
$308.00
$308.00
$823.00
20
$450.00
$235.00
$659.00
$367.00
$327.00
$327.00
$976.00
25
$500.00
$588.00
$1,459.00
$367.00
$414.00
$414.00
$1,129.00
30
$550.00
$588.00
$1,459.00
$416.00
$438.00
$438.00
$1,129.00
40
$850.00
$824.00
$1,471.00
$471.00
$664.00
$664.00
$1,600.00
N-F Disc
Fsd Disc
Input Fuse
In-React
Out-React
3-Cnt Bypass
460 VAC Drive Adder
HP
2-18
CB
5
$400.00
$235.00
$412.00
$99.00
$290.00
$290.00
$545.00
7.5
$400.00
$235.00
$412.00
$99.00
$315.00
$315.00
$545.00
10
$400.00
$235.00
$412.00
$99.00
$350.00
$350.00
$545.00
15
$400.00
$235.00
$412.00
$165.00
$400.00
$400.00
$545.00
20
$400.00
$235.00
$494.00
$188.00
$423.00
$423.00
$545.00
25
$400.00
$305.00
$494.00
$200.00
$423.00
$423.00
$640.00
30
$550.00
$305.00
$538.00
$214.00
$490.00
$490.00
$800.00
40
$550.00
$353.00
$720.00
$367.00
$515.00
$515.00
$900.00
50
$550.00
$353.00
$720.00
$367.00
$575.00
$575.00
$1,125.00
60
$550.00
$835.00
$1,212.00
$416.00
$585.00
$585.00
$1,125.00
75
$700.00
$835.00
$1,212.00
$471.00
$795.00
$795.00
$1,570.00
100
$800.00
$950.00
$1,650.00
$682.00
$890.00
$890.00
$1,570.00
125
$1,100.00
$950.00
$1,650.00
$710.00
$1,090.00
$1,090.00
$1,650.00
benshaw.com
Return to the
Table of Contents
Standard Low Voltage Drive Options
Input Line Reactors
3% Impedance
230 V
Model Number
Open Dimensions (in.)
Open
REA-KDRA25L
Enclosed (NEMA 1)
REA-KDRA25L-C1
Enclosed Dimensions (in.)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
1
4.6
4
4.18
3.75
6.5
8
6
8
Open
List Price
Enclosed
List Price
$185.00
$400.00
REA-KDRA27L
REA-KDRA27L-C1
2
7.5
4
4.18
3.75
6.5
8
6
8
$200.00
$425.00
REA-KDRA28L
REA-KDRA28L-C1
3
10.6
4
4.18
3.75
6.5
8
6
8
$235.00
$445.00
REA-KDRB22L
REA-KDRB22L-C1
5
16.7
5
6
4
6.5
8
6
12
$300.00
$525.00
REA-KDRB23L
REA-KDRB23L-C2
7.5
24.2
5
6
4
7.5
10
7
14
$325.00
$575.00
REA-KDRD25L
REA-KDRD25L-C2
10
30.8
5.75
7.2
4.25
7.5
10
7
18
$355.00
$625.00
REA-KDRD24L
REA-KDRD24L-C2
15
46.2
5.75
7.2
4.25
7.5
10
7
18
$445.00
$700.00
REA-KDRD26L
REA-KDRD26L-C2
20
59.4
5.75
7.2
4.25
7.5
10
7
18
$475.00
$725.00
REA-KDRC22L
REA-KDRC22L-C2
25
74.8
5.75
7.2
5
7.5
10
7
21
$635.00
$885.00
REA-KDRF24L
REA-KDRF24L-C4
30
88
7
9
6
15.5
15
13
65
$650.00
$1,255.00
REA-KDRF25L
REA-KDRF25L-C4
40
114
7
9
6
15.5
15
13
65
$955.00
$1,565.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
Return to the
Table of Contents
2-19
Standard Low Voltage
Drive Options
Input Line Reactors
3% Impedance
480 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
REA-KDRA8L-C1
1
2.1
4
4.18
3.75
6.5
8
6
REA-KDRA1L-C1
2
3.4
4
4.18
3.75
6.5
8
6
8
$185.00
$400.00
8
$195.00
$410.00
REA-KDRA2L-C1
3
4.8
4
4.18
3.75
6.5
8
REA-KDRA3L
REA-KDRA3L-C1
5
7.6
4
4.18
3.75
6.5
8
6
8
$210.00
$425.00
6
8
$225.00
$445.00
REA-KDRA4L
REA-KDRA4L-C1
7.5
11
4
4.18
3.75
6.5
8
6
8
$250.00
$465.00
REA-KDRA5L
REA-KDRA5L-C1
10
14
4
4.18
3.75
REA-KDRB2L
REA-KDRB2L-C1
15
21
5
6
4
6.5
8
6
9
$315.00
$525.00
6.5
8
6
12
$365.00
$585.00
REA-KDRB1L
REA-KDRB1L-C1
20
27
5
6
4
REA-KDRD1L
REA-KDRD1L-C2
25
34
5.75
7.2
4.25
6.5
8
6
12
$400.00
$625.00
7.5
10
7
16
$425.00
$685.00
REA-KDRD2L
REA-KDRD2L-C2
30
40
5.75
7.2
4.25
7.5
10
7
16
$550.00
$795.00
REA-KDRC1L
REA-KDRC1L-C2
40
52
5.75
REA-KDRF2L
REA-KDRF2L-C3
50
65
7
7.2
5
7.5
10
7
21
$595.00
$855.00
9
6
9
12
8
37
$695.00
$1,065.00
REA-KDRF4L
REA-KDRF4L-C3
60
77
REA-KDRF3L
REA-KDRF3L-C4
75
96
7
9
6
9
12
8
42
$725.00
$1,085.00
7
9
6
15.5
15
13
65
$955.00
$1,565.00
REA-KDRH3L
REA-KDRH3L-C4
100
124
REA-KDRH2L
REA-KDRH2L-C4
125
156
7
9
7
15.5
15
13
65
$1,100.00
$1,725.00
9
11
7
15.5
15
13
75
$1,365.00
$1,985.00
REA-KDRH1L
REA-KDRH1L-C4
150
180
9
11
7
15.5
15
13
75
$1,600.00
$2,225.00
REA-KDRG3L
REA-KDRG3L-C4
REA-KDRG1L
REA-KDRG1L-C4
200
240
9
11
8
15.5
15
13
100
$2,050.00
$2,650.00
250
302
9
11
8
15.5
15
13
100
$2,245.00
$2,855.00
REA-KDRG2L
REA-KDRJ2L
REA-KDRG2L-C4
300
361
9
11
8
15.5
15
13
100
$2,295.00
$2,925.00
REA-KDRJ2L-C5
350
414
9
11
9
18.5
20
16
120
$2,655.00
$3,475.00
REA-KDRJ1L
REA-KDRJ1L-C5
400
477
9
11
9
18.5
20
16
120
$2,950.00
$3,750.00
REA-KDRL2L
REA-KDRL2L-C5
500
590
11.38
14.5
9.5
18.5
20
16
160
$5,165.00
$5,985.00
REA-KDRL3L
REA-KDRL3L-C5
600
720
11.38
14.5
9.5
18.5
20
16
205
$6,545.00
$7,355.00
REA-KDRS1L
REA-KDRS1L-C7
700
840
11.38
15
12.5
36
28.5
30.3
318
$7,650.00
$9,785.00
Open
Enclosed (NEMA 1)
REA-KDRA8L
REA-KDRA1L
REA-KDRA2L
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2-20
benshaw.com
Return to the
Table of Contents
Input Line Reactors
3% Impedance
600 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Open
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
REA-KDRA50L
REA-KDRA50L-C1
1
1.7
4
4.18
3.75
6.5
8
6
REA-KDRA46L
REA-KDRA46L-C1
2
2.7
4
4.18
3.75
6.5
8
6
8
$215.00
$425.00
8
$225.00
$435.00
REA-KDRA52L
REA-KDRA52L-C1
3
3.9
4
4.18
3.75
6.5
8
REA-KDRA47L
REA-KDRA47L-C1
5
6.1
4
4.18
3.75
6.5
8
6
8
$235.00
$450.00
6
8
$245.00
$465.00
REA-KDRA48L
REA-KDRA48L-C1
7.5
9
4
4.18
3.75
6.5
8
6
8
$285.00
$500.00
REA-KDRA49L
REA-KDRA49L-C1
10
11
4
4.18
3.75
6.5
8
6
9
$325.00
$550.00
REA-KDRB45L
REA-KDRB45L-C1
15
17
5
6
4
6.5
8
6
12
$365.00
$585.00
REA-KDRB44L
REA-KDRB44L-C1
20
22
5
6
4
6.5
8
6
12
$385.00
$600.00
REA-KDRB43L
REA-KDRB43L-C1
25
27
5
6
4
6.5
8
6
12
$425.00
$645.00
REA-KDRD42L
REA-KDRD42L-C2
30
32
5.75
7.2
4.25
7.5
10
7
18
$435.00
$685.00
REA-KDRC43L
REA-KDRC43-C2
40
41
5.75
7.2
5
7.5
10
7
21
$465.00
$725.00
REA-KDRC44L
REA-KDRC44L-C2
50
52
5.75
7.2
5
7.5
10
7
21
$495.00
$755.00
REA-KDRF46L
REA-KDRF46L-C3
60
62
7
9
6
9
12
8
42
$665.00
$1,025.00
REA-KDRF47L
REA-KDRF47L-C3
75
77
7
9
6
9
12
8
42
$695.00
$1,055.00
REA-KDRF45L
REA-KDRF45L-C4
100
99
7
9
6
15.5
15
13
65
$955.00
$1,565.00
REA-KDRH43L
REA-KDRH43L-C4
125
125
9
11
7
15.5
15
13
80
$1,085.00
$1,700.00
REA-KDRH44L
REA-KDRH44L-C4
150
144
9
11
7
15.5
15
13
80
$1,355.00
$1,965.00
REA-KDRI42L
REA-KDRI42L-C4
200
192
9
11
7
15.5
15
13
85
$1,445.00
$2,055.00
REA-KDRG47L
REA-KDRG47L-C4
250
242
9
11
8
15.5
15
13
100
$1,600.00
$2,225.00
REA-KDRG45L
REA-KDRG45L-C4
300
289
9
11
8
15.5
15
13
100
$1,885.00
$2,495.00
REA-KDRJ45L
REA-KDRJ45L-C5
350
336
9
11
9
18.5
20
16
120
$2,125.00
$2,925.00
REA-KDRJ43L
REA-KDRJ43L-C5
400
382
9
11
9
18.5
20
16
120
$2,250.00
$3,050.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
Return to the
Table of Contents
2-21
Standard Low Voltage
Drive Options
Input Line Reactors
5% Impedance
240 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
REA-KDRA25H
REA-KDRA25H-C1
1
4.6
4
4.18
3.75
6.5
8
6
REA-KDRA26H
REA-KDRA26H-C1
2
7.5
4
4.18
3.75
6.5
8
6
REA-KDRA28H
REA-KDRA28H-C1
3
10.6
4
4.18
3.75
6.5
8
REA-KDRB25H
REA-KDRB25H-C1
5
16.7
5
6
4
6.5
8
REA-KDRB26H
REA-KDRB26H-C1
7.5
24.2
5
6
4
6.5
REA-KDRD21H
REA-KDRD21H-C2
10
30.8
5.75
7.2
4.25
REA-KDRD22H
REA-KDRD22H-C2
15
46.2
5.75
7.2
4.25
REA-KDRC22H
REA-KDRC22H-C2
20
59.4
5.75
7.2
REA-KDRF28H
REA-KDRF28H-C3
25
74.8
7
9
REA-KDRF25H
REA-KDRF25H-C4
30
88
7
REA-KDRF26H
REA-KDRF26H-C4
40
114
7
Open
Open
List Price
Enclosed
List Price
8
$225.00
$435.00
8
$250.00
$465.00
6
8
$275.00
$485.00
6
12
$345.00
$555.00
8
6
12
$410.00
$625.00
7.5
10
7
18
$425.00
$675.00
7.5
10
7
18
$545.00
$795.00
5
7.5
10
7
21
$615.00
$865.00
6
9
12
8
42
$725.00
$1,085.00
9
6
15.5
15
13
65
$745.00
$1,355.00
9
6
15.5
15
13
65
$995.00
$1,625.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2-22
benshaw.com
Return to the
Table of Contents
Input Line Reactors
5% Impedance
480 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
REA-KDRA8H
REA-KDRA8H-C1
1
2.1
4.00
4.18
3.75
6.5
8
6
REA-KDRA1H
REA-KDRA1H-C1
2
3.4
4.00
4.18
3.75
6.5
8
6
8
$215.00
$425.00
8
$225.00
$445.00
REA-KDRA2H
REA-KDRA2H-C1
3
4.8
4.00
4.18
3.75
6.5
8
REA-KDRA3H
REA-KDRA3H-C1
5
7.6
4.00
4.18
3.75
6.5
8
6
8
$285.00
$500.00
6
8
$325.00
$545.00
REA-KDRA4H
REA-KDRA4H-C1
7.5
11
4.00
4.18
3.75
6.5
8
6
9
$375.00
$585.00
REA-KDRA5H
REA-KDRA5H-C1
10
14
4.00
4.18
3.75
REA-KDRB2H
REA-KDRB2H-C1
15
21
5.00
6.00
4.00
6.5
8
6
9
$465.00
$675.00
6.5
8
6
11
$475.00
$695.00
REA-KDRC3H
REA-KDRC3H-C1
20
27
5.75
7.20
5.0
REA-KDRC1H
REA-KDRC1H-C2
25
34
5.75
7.20
5.0
6.5
8
6
19
$535.00
$785.00
7.5
10
7
21
$635.00
$895.00
REA-KDRE2H
REA-KDRE2H-C2
30
40
5.75
7.20
5.0
7.5
10
7
22
$725.00
$985.00
REA-KDRF4H
REA-KDRF4H-C3
40
52
7.00
REA-KDRF1H
REA-KDRF1H-C3
50
65
7.00
9.00
6.00
9
12
8
37
$755.00
$1,125.00
9.00
6.00
9
12
8
37
$1,050.00
$1,400.00
REA-KDRF2H
REA-KDRF2H-C3
60
77
REA-KDRH2H
REA-KDRH2H-C4
75
96
7.00
9.00
6.00
9
12
8
37
$1,075.00
$1,445.00
9.00
11.00
7.00
15.5
15
13
80
$1,225.00
$1,835.00
REA-KDRI2H
REA-KDRI2H-C4
100
REA-KDRG3H
REA-KDRG3H-C4
125
124
9.00
11.00
7.00
15.5
15
13
87
$1,465.00
$2,075.00
156
9.00
11.00
7.00
15.5
15
13
90
$1,645.00
$2,255.00
REA-KDRG1H
REA-KDRG1H-C4
150
180
9.00
11.00
7.00
15.5
15
13
90
$2,000.00
$2,625.00
REA-KDRJ1H
REA-KDRL1H
REA-KDRJ1H-C5
200
240
9.00
11.00
7.00
18.5
20
16
120
$2,665.00
$3,485.00
REA-KDRL1H-C5
250
302
11.38
14.50
9.50
18.5
20
16
160
$2,915.00
$3,735.00
REA-KDRL2H
REA-KDRL3H
REA-KDRL2H-C5
300
361
11.38
14.50
9.31
18.5
20
16
145
$2,935.00
$3,750.00
REA-KDRL3H-C5
350
414
11.38
14.50
9.31
18.5
20
16
150
$3,345.00
$4,155.00
REA-KDRL4H
REA-KDRL4H-C5
400
477
11.38
14.50
9.50
18.5
20
16
160
$4,425.00
$5,250.00
REA-KDRL5H
REA-KDRL5H-C5
450
515
11.38
14.50
11.00
18.5
20
16
165
$4,625.00
$5,435.00
REA-KDRL6H
REA-KDRL6H-C5
500
590
11.38
14.50
11.00
18.5
20
16
170
$5,825.00
$6,650.00
REA-KDRS1H
REA-KDRS1H-C7
600
720
11.38
15.00
13.00
36
28.5
30.3
420
$7,025.00
$9,075.00
REA-KDRS2H
REA-KDRS2H-C7
700
840
11.38
15.00
13.00
36
28.5
30.3
420
$8,195.00
$9,825.00
Open
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
Return to the
Table of Contents
2-23
Standard Low Voltage
Drive Options
Input Line Reactors
5% Impedance
600 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Open
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
REA-KDRA50H
REA-KDRA50H-C1
1
1.7
4
4.18
3.75
6.5
8
6
8
$235.00
$445.00
REA-KDRA43H
REA-KDRA43H-C1
2
2.7
4
4.18
3.75
6.5
8
6
8
$245.00
$455.00
REA-KDRA44H
REA-KDRA44H-C1
3
3.9
4
4.18
3.75
6.5
8
6
8
$255.00
$465.00
REA-KDRA45H
REA-KDRA45H-C1
5
6.1
4
4.18
3.75
6.5
8
6
8
$350.00
$565.00
REA-KDRB42H
REA-KDRB42H-C2
7.5
9
5
6
4
7.5
10
7
14
$435.00
$695.00
REA-KDRB43H
REA-KDRB43H-C2
10
11
5
6
4
7.5
10
7
14
$485.00
$745.00
REA-KDRB44H
REA-KDRB44H-C2
15
17
5
6
4
7.5
10
7
14
$500.00
$755.00
REA-KDRD41H
REA-KDRD41H-C2
20
22
5.75
7.2
4.25
7.5
10
7
18
$535.00
$785.00
REA-KDRC43H
REA-KDRC43H-C2
25
27
5.75
7.2
5
7.5
10
7
21
$575.00
$835.00
REA-KDRE42H
REA-KDRE42H-C2
30
32
5.75
7.2
5
7.5
10
7
22
$675.00
$925.00
REA-KDRF44H
REA-KDRF44H-C3
40
41
7
9
6
9
12
8
42
$795.00
$1,165.00
REA-KDRF45H
REA-KDRF45H-C3
50
52
7
9
6
9
12
8
42
$1,025.00
$1,385.00
REA-KDRH43H
REA-KDRH43H-C4
60
62
9
11
6
15.5
15
13
80
$1,095.00
$1,715.00
REA-KDRH42H
REA-KDRH42H-C4
75
77
9
11
6
15.5
15
13
80
$1,145.00
$1,755.00
REA-KDRI41H
REA-KDRI41H-C4
100
99
9
11
7
15.5
15
13
85
$1,665.00
$2,275.00
REA-KDRG44H
REA-KDRG44H-C4
125
125
9
11
7.5
15.5
15
13
100
$1,755.00
$2,365.00
REA-KDRG45H
REA-KDRG45H-C4
150
144
9
11
8
15.5
15
13
100
$1,825.00
$2,445.00
REA-KDRJ41H
REA-KDRJ41H-C5
200
192
9
11
9
18.5
20
16
120
$2,325.00
$3,145.00
REA-KDRL46H
REA-KDRL46H-C5
250
242
11.38
15
11
18.5
20
16
160
$3,265.00
$4,085.00
REA-KDRL47H
REA-KDRL47H-C5
300
289
11.38
15
11
18.5
20
16
160
$3,325.00
$4,145.00
REA-KDRL48H
REA-KDRL48H-C5
350
336
11.38
15
11
18.5
20
16
160
$3,455.00
$4,255.00
REA-KDRL49H
REA-KDRL49H-C5
400
382
11.38
15
11
18.5
20
16
160
$3,555.00
$4,345.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.
2-24
benshaw.com
Return to the
Table of Contents
Output Reactors
1.5% Impedance
480 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
REA-KDRA1P-C1
2
3.4
4
4.18
3.75
8
6.5
8
REA-KDRA2P-C1
3
4.8
4
4.18
3.75
8
6.5
8
Open
Enclosed (NEMA 1)
REA-KDRA1P
REA-KDRA2P
Open
List Price
Enclosed
List Price
6
$245.00
$455.00
6
$295.00
$505.00
REA-KDRA3P
REA-KDRA3P-C1
5
7.6
4
4.18
3.75
8
6.5
8
6
$300.00
$515.00
REA-KDRA4P
REA-KDRA4P-C1
7.5
11
4
4.18
3.75
9
6.5
8
6
$325.00
$525.00
REA-KDRB1P
REA-KDRB1P-C1
10
14
5
6
4
11
6.5
8
6
$425.00
$645.00
REA-KDRD1P
REA-KDRD1P-C2
15
21
6
7.2
4.25
16
7.5
10
7
$445.00
$695.00
REA-KDRD2P
REA-KDRD2P-C2
20
27
6
7.2
4.25
16
7.5
10
7
$455.00
$725.00
REA-KDRD3P
REA-KDRD3P-C2
25
34
6
7.2
4.25
18
7.5
10
7
$475.00
$745.00
REA-KDRD4P
REA-KDRD4P-C2
30
40
6
7.2
4.25
18
7.5
10
7
$600.00
$855.00
REA-KDRC1P
REA-KDRC1P-C2
40
52
5.75
7.2
5
21
7.5
10
7
$665.00
$925.00
REA-KDRF1P
REA-KDRF1P-C3
50
65
7
9
6
37
9
12
8
$775.00
$1,150.00
REA-KDRF2P
REA-KDRF2P-C3
60
77
7
9
6
37
9
12
8
$795.00
$1,165.00
96
7
9
6
65
15.5
15
13
$1,065.00
$1,675.00
REA-KDRF3P
REA-KDRF3P-C4
75
REA-KDRH1P
REA-KDRH1P-C4
100
124
9
11
7
75
15.5
15
13
$1,235.00
$1,845.00
REA-KDRI1P
REA-KDRI1P-C4
125
156
9
11
7
85
15.5
15
13
$1,525.00
$2,135.00
REA-KDRI2P
REA-KDRI2P-C4
150
180
9
11
7
90
15.5
15
13
$1,785.00
$2,395.00
REA-KDRG1P
REA-KDRG1P-C4
200
240
9
11
8
95
15.5
15
13
$2,265.00
$2,875.00
REA-KDRJ1P
REA-KDRJ1P-C5
250
302
9
11
9
120
18.5
20
16
$2,495.00
$3,315.00
REA-KDRJ2P
REA-KDRJ2P-C5
300
361
9
11
9
120
18.5
20
16
$2,550.00
$3,365.00
REA-KDRL1P
REA-KDRL1P-C5
350
414
11.38
14.5
9.31
135
18.5
20
16
$2,950.00
$3,765.00
REA-KDRL2P
REA-KDRL2P-C5
400
477
11.38
14.5
9.31
145
18.5
20
16
$3,255.00
$4,075.00
REA-KDRL3P
REA-KDRL3P-C5
450
515
11.38
14.5
9.31
150
18.5
20
16
$3,775.00
$4,595.00
REA-KDRL4P
REA-KDRL4P-C5
500
590
11.38
14.5
9.31
150
18.5
20
16
$5,745.00
$6,555.00
230 V drives/motors can operate with extended lead lengths (<500 ft.) without a load reactor.
If the installation is >500 ft. or involves multiple motors from one drive, use an appropriately sized (current) 480 V reactor or a long lead filter.
Return to the
Table of Contents
2-25
Standard Low Voltage
Drive Options
Output Reactors
1.5% Impedance
600 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
REA-KDRA31P
REA-KDRA31P-C1
2
2.7
4
4.18
3.75
8
6.5
8
REA-KDRA35P
REA-KDRA35P-C1
3
3.9
4
4.18
3.75
8
6.5
8
Open
Open
List Price
Enclosed
List Price
6
$285.00
$500.00
6
$350.00
$565.00
REA-KDRA33P
REA-KDRA33P-C1
5
6.1
4
4.18
3.75
8
6.5
8
6
$365.00
$585.00
REA-KDRA34P
REA-KDRA34P-C1
7.5
9
4
4.18
3.75
9
6.5
8
6
$425.00
$625.00
REA-KDRA36P
REA-KDRA36P-C1
10
11
4
4.18
3.75
9
6.5
8
6
$515.00
$725.00
REA-KDRD31P
REA-KDRD31P-C2
15
17
5.75
7.2
4.25
16
7.5
10
7
$525.00
$785.00
REA-KDRD32P
REA-KDRD32P-C2
20
22
5.75
7.2
4.25
16
7.5
10
7
$585.00
$845.00
REA-KDRD35P
REA-KDRD35P-C2
25
27
5.75
7.2
4.25
16
7.5
10
7
$705.00
$965.00
REA-KDRD33P
REA-KDRD33P-C2
30
32
5.75
7.2
4.25
18
7.5
10
7
$805.00
$1,065.00
REA-KDRD34P
REA-KDRD34P-C2
40
41
5.75
7.2
4.25
18
7.5
10
7
$825.00
$1,095.00
REA-KDRC31P
REA-KDRC31P-C2
50
52
5.75
7.2
5
21
7.5
10
7
$1,155.00
$1,425.00
REA-KDRF31P
REA-KDRF31P-C3
60
62
7
9
6
37
9
12
8
$1,195.00
$1,565.00
REA-KDRF32P
REA-KDRF32P-C3
75
77
7
9
6
37
9
12
8
$1,355.00
$1,725.00
REA-KDRF33P
REA-KDRF33P-C4
100
99
7
9
6
65
15.5
15
13
$1,625.00
$2,245.00
REA-KDRH31P
REA-KDRH31P-C4
125
125
9
11
7
75
15.5
15
13
$1,825.00
$1,445.00
REA-KDRI31P
REA-KDRI31P-C4
150
144
9
11
7
85
15.5
15
13
$2,235.00
$2,850.00
REA-KDRI32P
REA-KDRI32P-C4
200
192
9
11
7
90
15.5
15
13
$2,965.00
$3,585.00
REA-KDRG31P
REA-KDRG31P-C4
250
242
9
11
8
95
15.5
15
13
$3,235.00
$3,845.00
REA-KDRJ31P
REA-KDRJ31P-C5
300
289
9
11
9
120
18.5
20
16
$3,255.00
$4,075.00
REA-KDRJ32P
REA-KDRJ32P-C5
350
336
9
11
9
120
18.5
20
16
$3,725.00
$4,535.00
REA-KDRL31P
REA-KDRL31P-C5
400
382
11.38
14.5
9.31
135
18.5
20
16
$4,925.00
$5,750.00
2-26
benshaw.com
Return to the
Table of Contents
Long Lead Filters (DV / DT)
240 V
Model Number
Open Dimensions (in.)
Enclosed Dimensions (in.)
Open
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
FLTR-V1K3A00
FLTR-V1K3A01
0.5
3
9.00
5.50
7.25
9
5.5
10
11
$885.00
$1,395.00
FLTR-V1K4A00
FLTR-V1K4A01
0.75
4
9.00
5.50
7.25
9
5.5
10
11
$915.00
$1,400.00
FLTR-V1K6A00
FLTR-V1K6A01
1~1.5
6
9.00
5.50
7.25
9
FLTR-V1K8A00
FLTR-V1K8A01
2
8
9.00
5.50
8.25
9
5.5
10
11
$935.00
$1,425.00
5.5
10
11
$950.00
$1,455.00
FLTR-V1K12A00
FLTR-V1K12A01
3
12
9.00
5.50
8.25
FLTR-V1K16A00
FLTR-V1K16A01
5
16
9.00
5.50
8.25
9
5.5
10
11
$985.00
$1,525.00
9
5.5
10
15
$995.00
$1,545.00
FLTR-V1K25A00
FLTR-V1K25A01
7.5
25
9.00
5.50
FLTR-V1K35A00
FLTR-V1K35A01
10
35
12.00
8.00
8.25
9
5.5
10
15
$1,325.00
$1,725.00
9.00
12
8
11.5
23
$1,435.00
$1,845.00
FLTR-V1K45A00
FLTR-V1K45A01
15
45
12.00
8.00
9.00
12
8
11.5
23
$1,495.00
$1,900.00
FLTR-V1K55A00
FLTR-V1K55A01
20
55
FLTR-V1K80A00
FLTR-V1K80A01
25~30
80
12.00
8.00
9.00
12
8
11.5
23
$1,545.00
$2,075.00
12.00
8.00
9.00
12
8
11.5
29
$2,175.00
$2,705.00
FLTR-V1K110A00
FLTR-V1K110A01
40
110
12.00
8.00
10.25
16.5
18
15
68
$2,555.00
$3,715.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV/DT.
Return to the
Table of Contents
2-27
Standard Low Voltage
Drive Options
Long Lead Filters (DV / DT)
480 V
Open Dimensions
(in.)
Model Number
Enclosed Dimensions
(in.)
Open
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
Open
List Price
Enclosed
List Price
FLTR-V1K2A00
FLTR-V1K2A01
0.75
2
9
5.5
7.25
9
5.5
10
11
$865.00
$1,385.00
FLTR-V1K3A00
FLTR-V1K3A01
1~1.5
3
9
5.5
7.25
9
5.5
FLTR-V1K4A00
FLTR-V1K4A01
2
4
9
5.5
7.25
9
5.5
10
11
$885.00
$1,395.00
10
11
$915.00
$1,400.00
FLTR-V1K6A00
FLTR-V1K6A01
3
6
9
5.5
7.25
9
FLTR-V1K8A00
FLTR-V1K8A01
5
8
9
5.5
8.25
9
5.5
10
11
$935.00
$1,425.00
5.5
10
11
$945.00
$1,445.00
FLTR-V1K12A00
FLTR-V1K12A01
7.5
12
9
5.5
8.25
9
5.5
10
11
$985.00
$1,525.00
FLTR-V1K16A00
FLTR-V1K16A01
10
16
9
5.5
FLTR-V1K18A00
FLTR-V1K18A01
10
18
9
5.5
8.25
9
5.5
10
15
$995.00
$1,550.00
8.25
9
5.5
10
15
$1,095.00
$1,625.00
FLTR-V1K21A00
FLTR-V1K21A01
15
21
9
FLTR-V1K25A00
FLTR-V1K25A01
15
25
9
5.5
8.25
9
5.5
10
15
$1,245.00
$1,685.00
5.5
8.25
9
5.5
10
15
$1,325.00
$1,725.00
FLTR-V1K27A00
FLTR-V1K27A01
20
27
FLTR-V1K35A00
FLTR-V1K35A01
25
35
9
5.5
8.25
9
5.5
10
15
$1,375.00
$1,785.00
12
8
9
12
8
11.5
23
$1,435.00
$1,845.00
FLTR-V1K45A00
FLTR-V1K45A01
30
45
12
8
9
12
8
11.5
23
$1,495.00
$1,905.00
FLTR-V1K55A00
FLTR-V1K55A01
40
FLTR-V1K80A00
FLTR-V1K80A01
50~60
55
12
8
9
12
8
11.5
23
$1,545.00
$2,075.00
80
12
8
9
12
8
11.5
29
$2,175.00
$2,705.00
FLTR-V1K110A00
FLTR-V1K110A01
75
110
12
8
10.25
16.5
18
15
68
$2,555.00
$3,715.00
FLTR-V1K130A00
FLTR-V1K130A01
100
130
8.5
11.75
9.5
16.5
18
15
83
$2,985.00
$4,185.00
FLTR-V1K160A00
FLTR-V1K160A01
125
160
8.5
11.75
10.5
16.5
18
15
83
$3,295.00
$4,495.00
FLTR-V1K200A00
FLTR-V1K200A01
150
200
8.5
11.75
9.25
16.5
18
15
93
$3,585.00
$4,675.00
FLTR-V1K250A00
FLTR-V1K250A01
200
250
8.5
11.75
9.25
16.5
18
15
93
$3,685.00
$4,765.00
FLTR-V1K305A00
FLTR-V1K305A01
250
305
8.75
11.75
12.25
16.5
18
30
117
$4,000.00
$4,795.00
FLTR-V1K362A00
FLTR-V1K362A01
300
362
8.75
11.75
12
16.5
18
30
117
$4,585.00
$5,335.00
FLTR-V1K420A00
FLTR-V1K420A01
350
420
10
11.75
13.75
16.5
18
30
132
$5,315.00
$5,785.00
FLTR-V1K480A00
FLTR-V1K480A01
400
480
10
11.75
13.75
16.5
18
30
138
$5,675.00
$6,485.00
FLTR-V1K600A00
FLTR-V1K600A01
500
600
12.75
15
13.75
16.5
18
30
168
$5,945.00
$7,085.00
FLTR-V1K750A00
FLTR-V1K750A01
600
750
12.75
15
14.5
16.5
18
30
180
$9,695.00
$12,695.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV / DT.
2-28
benshaw.com
Return to the
Table of Contents
Long Lead Filters (DV / DT)
600 V
Open Dimensions
(in.)
Model Number
Enclosed Dimensions
(in.)
Enclosed (NEMA 1)
HP
A
H
W
D
H
W
D
Weight
(lbs.)
FLTR-V1K2A00
FLTR-V1K2A01
1
2
9
5.5
7.25
9
5.5
10
FLTR-V1K3A00
FLTR-V1K3A01
2
3
9
5.5
7.25
9
5.5
FLTR-V1K4A00
FLTR-V1K4A01
3
4
9
5.5
7.25
9
5.5
FLTR-V1K8A00
FLTR-V1K8A01
5
8
9
5.5
8.25
9
FLTR-V1K12A00
FLTR-V1K12A01
10
12
9
5.5
8.25
9
FLTR-V1K18A00
FLTR-V1K18A01
15
18
9
5.5
8.25
FLTR-V1K25A00
FLTR-V1K25A01
20
25
9
5.5
FLTR-V1K27A00
FLTR-V1K27A01
25
27
9
5.5
FLTR-V1K35A00
FLTR-V1K35A01
30
35
12
FLTR-V1K45A00
FLTR-V1K45A01
40
45
12
FLTR-V1K55A00
FLTR-V1K55A01
50
55
Open
Open
List Price
Enclosed
List Price
11
$865.00
$1,385.00
10
11
$885.00
$1,395.00
10
11
$915.00
$1,415.00
5.5
10
11
$945.00
$1,455.00
5.5
10
11
$985.00
$1,525.00
9
5.5
10
15
$1,095.00
$1,625.00
8.25
9
5.5
10
15
$1,325.00
$1,725.00
8.25
9
5.5
10
15
$1,375.00
$1,785.00
8
9
12
8
11.5
23
$1,435.00
$1,845.00
8
9
12
8
11.5
23
$1,495.00
$1,905.00
12
8
9
12
8
11.5
23
$1,545.00
$2,075.00
FLTR-V1K80A00
FLTR-V1K80A01
75
80
12
8
9
12
8
11.5
29
$2,175.00
$2,705.00
FLTR-V1K110A00
FLTR-V1K110A01
100
110
12
8
10.25
16.5
18
15
68
$2,555.00
$3,715.00
FLTR-V1K130A00
FLTR-V1K130A01
125
130
8.5
11.75
9.5
16.5
18
15
83
$2,985.00
$4,185.00
FLTR-V1K160A00
FLTR-V1K160A01
150
160
8.5
11.75
10.5
16.5
18
15
83
$3,295.00
$4,495.00
FLTR-V1K200A00
FLTR-V1K200A01
200
200
8.5
11.75
9.25
16.5
18
15
933
$3,585.00
$4,685.00
FLTR-V1K250A00
FLTR-V1K250A01
250
250
8.5
11.75
9.25
16.5
18
15
93
$3,685.00
$4,765.00
FLTR-V1K305A00
FLTR-V1K305A01
300
305
8.75
11.75
12.25
16.5
18
30
117
$4,015.00
$4,795.00
FLTR-V1K362A00
FLTR-V1K362A01
350
362
8.75
11.75
12
16.5
18
30
117
$4,585.00
$5,345.00
FLTR-V1K420A00
FLTR-V1K420A01
450
420
10
11.75
13.75
16.5
18
30
132
$5,325.00
$5,785.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV / DT.
Return to the
Table of Contents
2-29
Dynamic Brake Resistors
and Brake Modules
Dynamic brake resistors and modules are used to address over voltage conditions with drives. Over voltage trips occur when the DC bus in
the drive increases to the over voltage trip level. This increase in voltage occurs when the mechanical energy in the motor is converted into
regenerative electrical energy, which is transferred back into the drive (the motor acts like a generator).
Regeneration occurs when:
• The deceleration time is too quick
• The load has high inertia and keeps rotating after the drive output power has decreased
below that of the load (Ex: fly wheels, large fans)
• The load is an over hauling load, cyclical or periodic (Ex: pump jack, punch press)
• When the motor suddenly becomes unloaded (Ex: lumber mill saw applications)
Regeneration can occur on an occasional basis
or periodically (cyclical) depending on the
type of load. A dynamic brake module and
resistor are required to be added to the drive
to dissipate this excess power. The module
and resistor must be sized correctly
depending on the application.
Contact Benshaw for assistance with sizing brake resistors and brake modules.
2-30
benshaw.com
Return to the
Table of Contents
Engineered Low Voltage Drive Packages
Overview
Benshaw is a recognized industry leader in the shipment of engineered drives from our stateof-the-art factory, with dedicated engineering teams and a complete inventory of components
necessary to build engineered solutions for you. Select the enclosure, disconnect, bypass, pilot
devices, control strategy and filters required to meet your most demanding applications.
Control Modifications — Whatever You Specify
• Pilot devices, control power transformers, switches, meters,
relays, space heaters, protective devices, PLCs, etc.
Combination Drive Packages — To Meet Your Requirements
• Circuit breaker protection
• Non-fused disconnect protection
• Fusible disconnect protection
• Flange or rotary handle mechanism
Bypass Packages — To Fit Your Application
• Three contactor
• Reduced voltage solid state starters
Enclosures — To Match Your Environment
• Standard designs — NEMA 1, 12, 3R
• Custom enclosures
• Special enclosures — 4, 4X, air conditioned
• Motor control centers
Filters — For Your Unique Application
• Line reactors 3% and 5%
• Long lead filters
• Load reactors
• Harmonic filters
• 18 pulse systems
Benshaw builds customized
engineered solutions
to meet your most
demanding applications.
Return to the
Table of Contents
2-31 2-31
Engineered Low
Voltage Drive Products
VFD Pre-Order Check List
2
Transformer
1
Purchaser Information
Company Name_______________________________________________________________________
3
MCC
Other Loads
Contact Person________________________________________________________________________
Email_________________________________________________________________________________
7
4
Enclosure 16
Address ______________________________________________________________________________
Phone Number________________________________________________________________________
L
5
17
19
Fuse
Supply —
Incoming
r
1
6
Primary (Input) Volts _____ VAC
_____KVA _____% Impedance
Short Circuit Capability _____ ISC (Amps)
Secondary (Output) Volts _____
WYE-Delta Connection:
7
9
VFD
RSi
B+
BDBR
8
PCC (Point
of Common
Coupling)
r
2
 Grounded
 Yes
 No
 Yes
 No
 Ungrounded
Harmonic Restrictions at PCC:
 IEEE 519-1992
Other Connected
Loads
r
Other Connected Loads Present?
Please list in detail in comments.
Ex. PFCC, VFD, etc.
 Yes
 No
Feeder Cable
r
Cable Length _____
 Conduit
 Teck
 NonShielded
3
4
 Shielded
10
Main Disconnect
MECH.
INTERLOCK
11
12
T
13
MOTOR
14
LOAD
20
2-32
Input Isolation
Contactor
Harmonic
Suppression
r
r
r
5
 Breaker
 Fusible Disc.
 Line Fuses
KAIC Rating
_____
6
 Yes
 No
 HP Rated
 NEMA
Rated
 Transformer
 Passive Filter
 Active
Filter
7
Input Line Reactor
3  or 5  % Imp.
 18 Pulse
 RFI/EMI Filter
VFD Ratings
r
VFD - HP _____ KVA _____ KW _____
V _____
Dynamic Braking
r
Load Type:
 Decel Only
 Overhauling
Duty Cycle
 5%
 10%
 50%
 100%
8
9
CT  VT  Volts _____
Amps _____
Model - RSi - _____ HP - _____ V - _____ Encl.
r
 Reactor
 Long Lead
 Sine Wave
300 ft. ~ 1500 ft.
> 1500 ft.
Bypass
r
50 ft. ~ 300 ft.
 2 Contactor
 3 Contactor
 RVSS
r
 NEMA Rated
 IEC Rated
Overload
For ATL Bypass only: Class 1-40 _____
Output Filter
10
11
12
 25%
 HP Rated
21
benshaw.com
Return to the
Table of Contents
VFD Pre-Order Check List
Cable Length
Motor Name
Plate Data
rSee r
13
r
14
10
Manufacturer _______________________
Length _____ Ft _____ M _____
Cable Specification:
 Non-Shielded
 Shielded
 Conduit
Insulation VFD Grade NEMA MG 1 -1998,
Part 3 1.4.4.2
 Yes
 No; See
Over temperature protection:
Thermostat
Thermistor
RTD and type
 10 Cu
Manufacturer _________________________
HP _____________ Volts ________________
RPM _______ FLA _______ S.F. __________
Amps ________ KVA/Code_____________
Design____________ Frame_____________
Breakdown torque _______% _______lb-ft
Temperature Rise ___________________°C
Critical speed ____________________ RPM
Options
r
15
 100 Pt
r
10
 100 Ni
 20 Ni
Does the motor require a blower for low speed operation?
 Yes
 No
Insulated Bearing(s)
 No
 Yes
 Start P/B
 Local/Remote Sw.
 Stop P/B
 Pilot Lights
 Emergency Stop P/B
 - Run/Stop
 HOA Switch
 - Forward/Reverse
 Forward P/B
 - Jog
 Reverse P/B
 - Power
 Jog Forward P/B
 - Fault
 Jog Reverse P/B
 Potentiometer
 Fault Reset P/B
Enclosure
r
16
 Other____________________________________________
UL Type ________ (1, 12, 3R, 4, 4X)
Ambient temperature range _____°C to _____°C
Altitude 0 to 3,300 ft. (1,000m)  Other ________________
Cable Entry/Exit Locations __________________
Enclosure Size
Restrictions
Control
Return to the
Table of Contents
r
17
H ________
W _________
D __________
Description ____________________________________________________________________
 Keypad
 Multi-Motor
 Terminal
 Master
 0 to 5 VDC
 Analog Outputs
 0 to 10 VDC
 Analog Inputs
 ± 10 VDC
 Digital Inputs
 0/4 to 20 mA
 Relay Outputs
 Follower
2-33
Engineered Low
Voltage Drive Products
VFD Pre-Order Check List
VFD Pre-Order Check List (continued)
Communications
Moters
r
 DeviceNet
 ModBus RTU
r
 Profibus
 Other _______________
Motor Amps ______
Motor Volts ____________
18
19
Frequency ________ RPM __________________
Other (Please Specify) ______________________
Application
Details
r
20
 Constant Torque
(150% for 60s)
 Standard-Duty
Torque (120%
for 60s)
 Variable
Torque (110%
for 60s)
 Load-Steady
 Pulsing
 Regenerative
Speed Range _______ to _______ RPM
 Load Flywheel Inertia (WK²)
 Load Torque Profile
 Breakaway Torque lb.-ft.
Breakaway Torque Duration _______ sec.
Max. Peak Torque _______ lb.-ft.
Accel. Time _______ Decel. Time _______
 Torque vs. Speed Curve
Deceleration:
 Coast
 Ramp
 DC Injection
Pump/Fan
Speed _______ Min. Speed _______ Starting and stopping cycle (details) _______________________________________
Load Details
r
21
Holding Brake required?
 Yes
Fan
 Fin Fan Cooler
 Cooling Tower Fan
Pump
 Centrifugal
Pump
 Centrifugal
Compressor
Oil Pump
 Pumpjack (PG)
 Progressive Cavity Screw Pump (PCP)
Conveyor
 Screw
Conveyor
 Belt
Conveyor
 Flat Conveyor
Extruder
 Single
Extruder
 Dual
Extruder
 Piston Extruder
Other
 Number
Throws
 Centrifuge
 Canter Line
 Step-up
Transformer:
 KVA
 Vprim
 No
 Electrical Submersible
Pump (ESP)
Gear ratio/Sheave ratio (Motor RPM/Load RPM) _____:_____
 PD Pump
 Slurry Pump
 Bucket
Conveyor
 Air
Conveyor
 Vsec
VZ
 Single-phase input
Additional Comments:______________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________
2-34
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
Engineered Packages
Part Number Assembler
RSI
VFD
RSI
060
SG
4
NC
RediStart
Inverter
SG
=
Sensorless
Vector Drive
A
=
Packaged Drive,
No Bypass
S4
=
Washdown
Sensorless
Vector Drive
C
=
Packaged Drive with
Three Contactor Bypass
SS
=
Packaged Drive with
Soft Starter (RVSS)
Bypass**
Horsepower
1
=
1 HP
2
=
2 HP
3
=
3 HP
5
=
5 HP
7
=
7.5 HP
10
=
10 HP
15
=
15 HP
20
=
20 HP
25
=
25 HP
30
=
30 HP
40
=
40 HP
50
=
50 HP
60
=
60 HP
75
=
75 HP
100
=
100 HP
125
=
125 HP
150
=
150 HP
200
=
200 HP
250
=
250 HP
300
=
300 HP
400
=
400 HP
500
=
500 HP
600
=
600 HP
700
=
700 HP
01
Package Type
VFD Series
=
A
Voltage
2
=
230 V
4
=
460 V
6
=
600 V
Disconnect Options
Enclosure**
NC
=
Non-Combination
1/12
=
NEMA 1/12
CB
=
Circuit Breaker
4
=
NEMA 4*
FD
=
Fusible Disconnect**
3R
=
NEMA 3R
* Air conditioning required.
** Consult factory.
Return to the
Table of Contents
2-35
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series
Enclosed Drives — Non-Combination Sensorless Vector Drives — 230 V
7.5–40 HP / NEMA 1 and 3R
Variable Torque
Standard Duty
Heavy Duty
Model Number
HP
Amps
HP
Amps
HP
Amps
A-1A
C-1A
A-3R
RSI-007-SG2-NC-XX
7.5
22
7.5
22
5
15.2
$6,200.00
$6,550.00
$6,255.00
$6,535.00
C-3R
RSI-010-SG2-NC-XX
10
29
10
29
7.5
22
$6,295.00
$6,655.00
$6,745.00
$7,100.00
RSI-015-SG2-NC-XX
15
42
15
42
10
28
$6,595.00
$7,000.00
$7,395.00
$7,825.00
RSI-020-SG2-NC-XX
20
54
20
54
15
42
$7,050.00
$7,555.00
$7,865.00
$8,355.00
RSI-025-SG2-NC-XX
25
68
25
68
20
54
$7,575.00
$8,275.00
$8,375.00
$9,065.00
RSI-030-SG2-NC-XX
30
80
30
80
25
68
$7,925.00
$8,795.00
$8,725.00
$9,595.00
RSI-040-SG2-NC-XX
40
104
40
104
30
80
$8,300.00
$9,385.00
$9,100.00
$10,185.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-50.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
2-36
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
SG Series
Enclosed Drives — Non-Combination Sensorless Vector Drives — 460 V
7.5–700 HP / NEMA 1 and 3R
Variable Torque
Standard Duty
Heavy Duty
Model Number
HP
Amps
HP
Amps
HP
Amps
RSI-007-SG4-NC-XX
7.5
11
7.5
11
5
8
$6,235.00
A-1A
$6,495.00
C-1A
$6,685.00
A-3R
$6,950.00
C-3R
RSI-010-SG4-NC-XX
10
14
10
14
7.5
11
$6,295.00
$6,575.00
$6,745.00
$7,050.00
RSI-015-SG4-NC-XX
15
21
15
21
10
14
$6,555.00
$6,950.00
$7,395.00
$7,745.00
RSI-020-SG4-NC-XX
20
27
20
27
15
21
$7,000.00
$7,400.00
$7,865.00
$8,205.00
RSI-025-SG4-NC-XX
25
34
25
34
20
27
$7,455.00
$7,825.00
$8,255.00
$8,625.00
RSI-030-SG4-NC-XX
30
40
30
40
25
34
$7,925.00
$8,355.00
$8,725.00
$9,155.00
RSI-040-SG4-NC-XX
40
52
40
52
30
40
$8,300.00
$8,795.00
$9,100.00
$9,595.00
RSI-050-SG4-NC-XX
50
65
50
65
40
52
$9,845.00
$10,525.00
$10,645.00
$11,345.00
RSI-060-SG4-NC-XX
60
77
60
77
50
65
$11,694.00
$12,625.00
$12,550.00
$13,485.00
RSI-075-SG4-NC-XX
75
96
75
96
60
77
$12,365.00
$13,525.00
$13,225.00
$14,385.00
RSI-100-SG4-NC-XX
100
125
100
125
75
96
$13,665.00
$15,395.00
$14,445.00
$16,185.00
RSI-125-SG4-NC-XX
125
156
125
156
100
125
$15,145.00
$19,765.00
$15,935.00
$18,335.00
RSI-150-SG4-NC-XX
150
180
150
180
125
156
$24,325.00
$27,825.00
$24,915.00
$24,875.00
RSI-200-SG4-NC-XX
200
240
200
240
150
180
$25,995.00
$30,000.00
$26,575.00
$32,425.00
RSI-250-SG4-NC-XX
250
302
250
302
200
240
$28,425.00
$33,000.00
$29,475.00
$34,775.00
RSI-350-SG4-NC-XX
350
414
350
361
250
302
$39,650.00
$44,615.00
$40,685.00
$45,665.00
RSI-400-SG4-NC-XX
400
477
400
477
300
361
$46,675.00
$54,925.00
$47,725.00
$55,975.00
RSI-500-SG4-NC-XX
500
590
500
515
350
414
$58,145.00
$69,675.00
$59,665.00
$62,205.00
RSI-600-SG4-NC-XX
600
731
600
590
400
477
$65,815.00
$77,625.00
$69,700.00
$79,145.00
RSI-700-SG4-NC-XX
700
877
700
804
500
590
$75,145.00
$118,825.00
$76,655.00
$120,945.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-50.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
Return to the
Table of Contents
2-37
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series
Enclosed Drives — Combination Circuit Breaker Sensorless Vector Drives — 230 V
7.5–40 HP / NEMA 1 and 3R
Variable Torque
Standard Duty
Heavy Duty
Model Number
HP
Amps
HP
Amps
HP
Amps
A-1A
C-1A
A-3R*
C-3R*
RSI-007-SG2-CB-XX
7.5
22
7.5
22
5
15.2
$6,555.00
$6,840.00
$7,000.00
$7,295.00
RSI-010-SG2-CB-XX
10
28
10
28
7.5
22
$6,625.00
$7,145.00
$7,075.00
$7,445.00
RSI-015-SG2-CB-XX
15
42
15
42
10
28
$6,945.00
$7,365.00
$7,735.00
$8,165.00
RSI-020-SG2-CB-XX
20
54
20
54
15
42
$7,455.00
$7,950.00
$8,255.00
$8,750.00
RSI-025-SG2-CB-XX
25
68
25
68
20
54
$7,965.00
$8,665.00
$8,775.00
$9,465.00
RSI-030-SG2-CB-XX
30
80
30
80
25
68
$8,500.00
$9,375.00
$9,300.00
$10,175.00
RSI-040-SG2-CB-XX
40
104
40
104
30
80
$9,100.00
$10,185.00
$9,900.00
$10,985.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
*Units should be mounted out of direct sunlight
For dimensions refer to page 2-50.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
2-38
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
SG Series
Enclosed Drives — Combination Circuit Breaker Sensorless Vector Drives — 460 V
7.5–700 HP / NEMA 1 and 3R
Variable Torque
Standard Duty
Heavy Duty
Model Number
HP
Amps
HP
Amps
HP
Amps
A-3R*
C-3R*
RSI-007-SG4-CB-XX
7.5
11
7.5
11
5
8
$6,535.00
A-1A
$6,795.00
C-1A
$6,985.00
$7,250.00
RSI-010-SG4-CB-XX
10
14
10
14
7.5
11
$6,595.00
$6,885.00
$7,045.00
$73,959.00
RSI-015-SG4-CB-XX
15
21
15
21
10
14
$6,895.00
$7,245.00
$7,695.00
$8,045.00
RSI-020-SG4-CB-XX
20
27
20
27
15
21
$7,355.00
$7,745.00
$8,195.00
$8,545.00
RSI-025-SG4-CB-XX
25
34
25
34
20
27
$7,795.00
$8,165.00
$8,595.00
$8,955.00
RSI-030-SG4-CB-XX
30
40
30
40
25
34
$8,265.00
$8,685.00
$9,065.00
$9,495.00
RSI-040-SG4-CB-XX
40
52
40
52
30
40
$8,695.00
$9,195.00
$9,495.00
$9,985.00
RSI-050-SG4-CB-XX
50
65
50
65
40
52
$10,250.00
$10,935.00
$11,050.00
$11,735.00
RSI-060-SG4-CB-XX
60
77
60
77
50
65
$12,315.00
$13,245.00
$13,165.00
$14,100.00
RSI-075-SG4-CB-XX
75
96
75
96
60
77
$13,685.00
$14,845.00
$14,545.00
$15,700.00
RSI-100-SG4-CB-XX
100
125
100
125
75
96
$14,975.00
$16,725.00
$15,765.00
$17,500.00
RSI-125-SG4-CB-XX
125
156
125
156
100
125
$16,465.00
$18,855.00
$17,255.00
$19,650.00
RSI-150-SG4-CB-XX
150
180
150
180
125
156
$25,895.00
$29,385.00
$23,365.00
$28,050.00
RSI-200-SG4-CB-XX
200
240
200
240
150
180
$27,555.00
$31,600.00
$28,145.00
$33,995.00
RSI-250-SG4-CB-XX
250
302
250
302
200
240
$30,735.00
$34,695.00
$31,785.00
$37,085.00
RSI-350-SG4-CB-XX
350
414
300
361
250
302
$42,350.00
$49,465.00
$43,395.00
$50,525.00
RSI-400-SG4-CB-XX
400
477
400
477
300
361
$50,445.00
$60,825.00
$51,495.00
$61,875.00
RSI-500-SG4-CB-XX
500
590
450
515
350
414
$61,500.00
$74,385.00
$63,050.00
$75,900.00
RSI-600-SG4-CB-XX
600
731
500
590
400
477
$72,600.00
$83,225.00
$74,125.00
$84,735.00
RSI-700-SG4-CB-XX
700
877
600
804
500
590
$81,935.00
$125,185.00
$87,445.00
$126,885.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
*Units should be mounted out of direct sunlight
For dimensions refer to page 2-50.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
2-39
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
S4 Series
Enclosed Drives — Non-Combination Severe Duty Sensorless Vector Drives — 230 V
1–20 HP / NEMA 12 and 3R
Standard Duty
Model Number
RSI-001-S42-NC-XX
Heavy Duty
HP
Amps
HP
Amps
1
7.6
-
-
A-12
$7,225.00
C-12
$7,500.00
A-3R
C-3R
$7,665.00
$7,965.00
RSI-002-S42-NC-XX
2
11
1
7.6
$7,395.00
$7,675.00
$7,845.00
$8,145.00
RSI-003-S42-NC-XX
3
14
2
11
$7,425.00
$7,725.00
$7,875.00
$8,175.00
RSI-005-S42-NC-XX
5
21
3
14
$7,735.00
$8,025.00
$8,185.00
$8,495.00
RSI-007-S42-NC-XX
7.5
27
5
21
$7,845.00
$8,145.00
$8,295.00
$8,565.00
RSI-010-S42-NC-XX
10
34
7.5
27
$9,100.00
$9,465.00
$9,555.00
$9,925.00
RSI-015-S42-NC-XX
15
40
10
34
$9,400.00
$9,825.00
$10,200.00
$10,645.00
RSI-020-S42-NC-XX
20
52
15
40
$11,485.00
$11,975.00
$12,285.00
$12,775.00
A-12 = VFD in NEMA 1 enclosure.
C-12 = VFD in NEMA 1 enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
2-40
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
S4 Series
Enclosed Drives — Non-Combination Severe Duty Sensorless Vector Drives — 460 V
1–200 HP / NEMA 12 and 3R
Standard Duty
Model Number
RSI-001-S44-NC-XX
Heavy Duty
HP
Amps
HP
Amps
1
2.1
-
-
A-12
$7,275.00
C-12
$7,545.00
A-3R
$7,725.00
C-3R
$7,985.00
RSI-002-S44-NC-XX
2
3.4
1
2.1
$7,425.00
$7,685.00
$7,875.00
$8,135.00
RSI-003-S44-NC-XX
3
4.8
2
3.4
$7,495.00
$7,695.00
$7,875.00
$8,195.00
RSI-005-S44-NC-XX
5
7.6
3
4.8
$7,775.00
$8,035.00
$8,225.00
$8,495.00
RSI-007-S44-NC-XX
7.5
11
5
7.6
$7,845.00
$8,100.00
$8,295.00
$8,555.00
RSI-010-S44-NC-XX
10
14
7.5
11
$7,895.00
$8,150.00
$8,315.00
$8,595.00
RSI-015-S44-NC-XX
15
21
10
14
$9,245.00
$9,635.00
$10,085.00
$10,425.00
RSI-020-S44-NC-XX
20
27
15
21
$9,285.00
$9,665.00
$10,125.00
$10,465.00
RSI-025-S44-NC-XX
25
34
20
27
$9,525.00
$9,885.00
$10,325.00
$10,685.00
RSI-030-S44-NC-XX
30
40
25
34
$9,665.00
$10,095.00
$10,465.00
$10,895.00
RSI-040-S44-NC-XX
40
52
30
40
$12,595.00
$13,085.00
$13,385.00
$13,885.00
RSI-050-S44-NC-XX
50
65
40
52
$12,955.00
$13,650.00
$13,755.00
$14,445.00
RSI-060-S44-NC-XX
60
77
50
65
$17,375.00
$18,245.00
$18,175.00
$19,045.00
RSI-075-S44-NC-XX
75
96
60
77
$17,645.00
$18,725.00
$18,445.00
$19,525.00
RSI-100-S44-NC-XX
100
124
75
96
$20,200.00
$21,825.00
$20,945.00
$22,565.00
RSI-125-S44-NC-XX
125
156
100
124
$25,375.00
$27,615.00
$26,115.00
$26,275.00
RSI-150-S44-NC-XX
150
180
125
156
$29,175.00
$32,050.00
$29,655.00
$34,015.00
RSI-200-S44-NC-XX
200
240
150
180
$29,925.00
$33,255.00
$30,400.00
$35,225.00
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
Return to the
Table of Contents
2-41
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
S4 Series
Enclosed Drives — Combination Circuit Breaker Severe Duty Sensorless Vector
Drives — 230 V
1–20 HP / NEMA 12 and 3R
Standard Duty
Model Number
Heavy Duty
HP
Amps
HP
Amps
RSI-001-S42-CB-XX
1
7.6
-
-
$7,515.00
A-12
$7,800.00
C-12
$7,665.00
A-3R
$8,255.00
C-3R
RSI-002-S42-CB-XX
2
11
1
7.6
$7,695.00
$7,975.00
$8,145.00
$8,425.00
RSI-003-S42-CB-XX
3
14
2
11
$7,725.00
$8,095.00
$8,195.00
$8,465.00
RSI-005-S42-CB-XX
5
21
3
14
$8,050.00
$8,325.00
$8,485.00
$8,775.00
RSI-007-S42-CB-XX
7.5
27
5
21
$8,135.00
$8,415.00
$8,595.00
$8,865.00
RSI-010-S42-CB-XX
10
34
7.5
27
$9,445.00
$9,800.00
$9,885.00
$10,255.00
RSI-015-S42-CB-XX
15
40
10
34
$9,735.00
$10,165.00
$10,555.00
$10,965.00
RSI-020-S42-CB-XX
20
52
15
40
$11,875.00
$12,625.00
$12,675.00
$13,175.00
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
2-42
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
S4 Series
Enclosed Drives — Combination Circuit Breaker Severe Duty Sensorless Vector
Drives — 460 V
1–200 HP / NEMA 12 and 3R
Standard Duty
Model Number
RSI-001-S44-CB-XX
Heavy Duty
HP
Amps
HP
Amps
1
2.1
-
-
A-12
$7,575.00
C-12
$7,845.00
A-3R
$8,025.00
C-3R
$8,285.00
RSI-002-S44-CB-XX
2
3.4
1
2.1
$7,725.00
$7,985.00
$8,175.00
$8,435.00
RSI-003-S44-CB-XX
3
4.8
2
3.4
$7,795.00
$7,995.00
$8,195.00
$8,495.00
RSI-005-S44-CB-XX
5
7.6
3
4.8
$8,075.00
$8,335.00
$8,525.00
$8,785.00
RSI-007-S44-CB-XX
7.5
11
5
7.6
$8,145.00
$8,425.00
$8,595.00
$8,855.00
RSI-010-S44-CB-XX
10
14
7.5
11
$8,195.00
$8,450.00
$8,625.00
$8,895.00
RSI-015-S44-CB-XX
15
21
10
14
$9,545.00
$9,935.00
$10,385.00
$10,735.00
RSI-020-S44-CB-XX
20
27
14
21
$9,625.00
$10,000.00
$10,465.00
$10,805.00
RSI-025-S44-CB-XX
25
34
20
27
$9,855.00
$10,225.00
$10,695.00
$11,025.00
RSI-030-S44-CB-XX
30
40
25
34
$10,000.00
$10,425.00
$10,800.00
$11,225.00
RSI-040-S44-CB-XX
40
52
30
40
$12,985.00
$13,475.00
$13,785.00
$14,275.00
RSI-050-S44-CB-XX
50
65
40
52
$13,350.00
$14,050.00
$14,150.00
$14,845.00
RSI-060-S44-CB-XX
60
77
50
65
$17,950.00
$18,825.00
$18,750.00
$19,625.00
RSI-075-S44-CB-XX
75
96
60
77
$18,875.00
$19,955.00
$19,675.00
$20,755.00
RSI-100-S44-CB-XX
100
124
75
96
$21,435.00
$23,050.00
$22,175.00
$23,795.00
RSI-125-S44-CB-XX
125
156
100
124
$26,625.00
$28,845.00
$27,345.00
$29,585.00
RSI-150-S44-CB-XX
150
180
125
156
$30,465.00
$33,350.00
$30,945.00
$35,300.00
RSI-200-S44-CB-XX
200
240
150
180
$31,250.00
$34,545.00
$31,695.00
$36,500.00
Dashes are shown for clarity.
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 –2-49.
Variable Torque = 110% current for 1 minute.
Standard Duty = 120% current for 1 minute.
Heavy Duty = 150% current for 1 minute.
Return to the
Table of Contents
2-43
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options — Pilot Devices
Push-Buttons
Model Number
Description
A001
Raised Stop Push-Button - Red
List Price
$85.00
A002
Flush Start Push-Button - Green
$85.00
A003
Jog Push-Button - Yellow
$85.00
A004
Ol Reset Push-Button - (For External Ol Relay) - Black
$85.00
A005
Reset Push-Button - Black
$85.00
A006
Raised Push-Button - Specify Color and Function
$85.00
A007
Flush Push-Button - Specify Color and Function
A008
Mushroom Head Stop Push-Button - Red
$125.00
$95.00
A009
Illuminated Push-Button - Specify Color and Function
$175.00
Pilot Lights
Model Number
Description
List Price
A021
Red Run Light
$125.00
A022
Green Stop Light
$125.00
A023
Amber Fault Light
$125.00
A024
Green Ready Light
$125.00
A025
Amber Bypass Light
$125.00
A026
Red Light - Specify Function
$145.00
A027
Green Light - Specify Function
$145.00
A028
Amber Light - Specify Function
$145.00
A029
White Light - Specify Function
$145.00
A030
Blue Light - Specify Function
$145.00
A031
Push to Test Contact Assembly (Addition to Above)
$200.00
A032
Power On Light - White
$175.00
Selector Switches
Model Number
Description
A041
Hand - Off - Auto Selector Switch
List Price
$175.00
A042
Local - Off - Remote Selector Switch
$175.00
A043
Key Operated Hand - Off - Auto Selector Switch
$225.00
A045
Two Postion Selector Switch - Specify Function
$195.00
A046
Three Position Selector Switch - Specify Function
$250.00
A047
Other Selector Switch - Specify Function and Type

Meters
Model Number
Description
A061
Single Phase Analog Ammeter - Includes CTs *
List Price
$300.00
A062
$300.00
A065
Analog Ammeter with Three Phase Selector Switch Includes CTs *
Elapsed Time Meter
A069
Other Power Metering - Specify Function
$475.00
$475.00
* Switchboard type
Space Heaters
Model Number
Description
A171
Space Heater with Thermostat
List Price
$450.00
Consult factory
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
2-44
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options — Line Reactors (Installed)
230 V - Input 3% AC Line Reactors
HP
Volt
A500
Model Number
1
230
List Price
$315.00
A501
2
230
$325.00
A502
3
230
$350.00
A503
5
230
$425.00
A504
7.5
230
$475.00
A505
10
230
$495.00
A506
15
230
$500.00
A507
20
230
$525.00
A508
25
230
$695.00
A509
30
230
$700.00
HP
Volt
List Price
A570
1
230
$325.00
A571
2
230
$350.00
230 V - Input 5% AC Line Reactors
Model Number
A572
3
230
$365.00
A573
5
230
$425.00
A574
7.5
230
$435.00
A575
10
230
$450.00
A576
15
230
$550.00
A577
20
230
$625.00
A578
25
230
$750.00
A579
30
230
$775.00
• Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
Return to the
Table of Contents
2-45
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options — Line Reactors (Installed)
460 V - Input 3% AC Line Reactors
HP
Volt
A520
Model Number
2
460
List Price
$195.00
A521
3
460
$235.00
A522
5
460
$255.00
A523
7.5
460
$285.00
A524
10
460
$365.00
A525
15
460
$375.00
A526
20
460
$415.00
A527
25
460
$475.00
A528
30
460
$550.00
A529
40
460
$595.00
A530
50
460
$735.00
A531
60
460
$815.00
A532
75
460
$925.00
A533
100
460
$1,025.00
A534
125
460
$1,395.00
A535
150
460
$1,550.00
A536
200
460
$2,000.00
A537
250
460
$2,200.00
A538
300
460
$2,300.00
A539
350
460
$2,495.00
A540
400
460
$3,325.00
A541
500
460
$4,125.00
A542
600
460
$5,225.00
A543
700
460
$6,125.00
• Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
2-46
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options — Line Reactors (Installed)
460 V - Input 5% AC Line Reactors
HP
Volt
A600
Model Number
2
460
List Price
$325.00
A601
3
460
$375.00
A602
5
460
$395.00
A603
7.5
460
$425.00
A604
10
460
$465.00
A605
15
460
$475.00
A606
20
460
$550.00
A607
25
460
$625.00
A608
30
460
$695.00
A609
40
460
$775.00
A610
50
460
$975.00
A611
60
460
$995.00
A612
75
460
$1,300.00
A613
100
460
$1,450.00
A614
125
460
$1,595.00
A615
150
460
$1,825.00
A616
200
460
$2,350.00
A617
250
460
$2,495.00
A618
300
460
$2,595.00
A619
350
460
$2,900.00
A620
400
460
$3,595.00
A621
500
460
$4,675.00
A622
600
460
$5,695.00
A623
700
460
$6,555.00
• Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
Return to the
Table of Contents
2-47
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options — Long Lead Filters (Installed)
460 V - Input 5% AC Line Reactors
HP
Volt
A640
Model Number
1
460
List Price
$945.00
A641
2
460
$950.00
A642
3
460
$975.00
A643
5
460
$995.00
A644
7.5
460
$1,100.00
A645
10
460
$1,125.00
A646
15
460
$1,200.00
A647
20
460
$1,295.00
A648
25
460
$1,350.00
A649
30
460
$1,395.00
A650
40
460
$1,425.00
A651
50 - 60
460
$1,895.00
A652
75
460
$2,500.00
A653
100
460
$2,825.00
A654
125
460
$3,000.00
A655
150
460
$3,200.00
A656
200
460
$3,250.00
A657
250
460
$3,300.00
A658
300
460
$3,650.00
A659
350
460
$3,925.00
A660
400
460
$4,400.00
A661
500
460
$9,000.00
A662
600
460

A663
700
460

• Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.
Consult factory
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
2-48
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options
Fast Acting Semiconductor Fuses
HP
Model Number
208V
240V
460V
575V
A670
2
3
5
7.5
List Price
$350.00
A671
3
-
7.5
10
$350.00
A672
-
5
10
15
$350.00
A673
5
7.5
15
20
$395.00
A674
7.5
10
20
25
$395.00
A675
10
-
25
30
$395.00
A676
-
15
30
40
$395.00
A677
15
20
40
50
$495.00
A678
20
25
50
60
$495.00
A679
25
30
60
75
$495.00
A680
30
40
75
100
$550.00
A681
40
50
100
125
$550.00
A682
40
60
125
150
$695.00
A683
60
75
150
200
$695.00
A684
75
100
200
250
$695.00
A685
100
125
250
300
$1,000.00
A686
125
150
300
400
$1,495.00
A686
150
200
400
500
$1,495.00
A687
200
250
500
600
$1,495.00
A688
250
300
600
700
$1,750.00
A689
300
350
700
-

NOTE: This option adds fast acting semiconductor fuses to the input of the VFD.
Consult factory
FOR ADDITIONAL OPTIONS - CONTACT FACTORY
Return to the
Table of Contents
2-49
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series Dimensions
230 V
Enclosure Dimensions
HP
No Options
With Circuit Breaker
or Line Reactor
7.5
10
15
20
25
30
40
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
3-Contactor Bypass
3-Contactor Bypass
& Circuit Breaker
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
460 V
Enclosure Dimensions
HP
No Options
With Circuit Breaker
or Line Reactor
3-Contactor Bypass
3-Contactor Bypass
& Circuit Breaker
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
350
400
500
600
700
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
46x30x16
46x30x16
87x31x24
87x31x24
87x31x24
87x37x24
87x37x24
87x48x24
87x48x24
87x48x24
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
46x30x16
46x30x16
87x31x24
87x31x24
87x37x24
87x48x24
87x48x24
87x48x24
87x72x24
87x72x24
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
70x30x24
70x30x24
87x48x24
87x48x24
87x48x24
87x48x24
87x48x24
87x72x24
87x72x24

30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
70x30x24
70x30x24
87x48x24
87x48x24
87x48x24
87x72x24
87x72x24
87x96x24
87x96x24

Consult factory
2-50
benshaw.com
Return to the
Table of Contents
Sensorless Vector Drives
S4 Series Dimensions
230 V
Enclosure Dimensions
HP
N12 No Options
With Circuit Breaker
or Line Reactor
3-Contactor Bypass
3-Contactor Bypass
& Circuit Breaker
1
2
3
5
7.5
10
15
20
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
460 V
Enclosure Dimensions
HP
N12 No Options
With Circuit Breaker
or Line Reactor
3-Contactor Bypass
3-Contactor Bypass
& Circuit Breaker
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
46x30x16
46x30x16
87x31x24
87x31x24
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
46x30x16
46x30x16
87x31x24
87x31x24
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
70x30x24
70x30x24
87x48x24
87x48x24
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
30x24x16
36x30x16
36x30x16
36x30x16
36x30x16
70x30x24
70x30x24
87x48x24
87x48x24
Return to the
Table of Contents
2-51
Integrated control solutions using both
Systems integration is a central focus of our business, and a competitive advantage
for our customers.
Benshaw’s success in the OEM and industrial
marketplace is a direct result of our willingness
as a company to think "beyond the box".
We’ve made systems integration a central
focus of our business, and we make learning
your business a top priority.
By focusing on the bigger picture we gain
a better understanding of your process,
your control requirements and your
market objectives.
We then apply that knowledge toward
the development and production of
complete, cost-effective, fully integrated
control solutions.
2-52
benshaw.com
Customized Enclosures:
Intelligent Motor Controls:
Benshaw takes great pride in our ability to
design and deliver custom control enclosures
that truly complement the form and function
of your machine.
Benshaw offers a full range of intelligent,
programmable, low and medium voltage
starters and drives—from fractional to 20,000
HP—to meet a variety of motor control needs.
NEMA 1, 12, 3R, 4 and 4X enclosures in unit
mount, console mount, free-standing and
wall-mount configurations are available
to suit your needs.
Motor control products include full voltage
starters, solid state reduced voltage starters
and variable frequency drives. Reversing, twospeed, DC braking, wye-delta, synchronous
and wound rotor control are supported.
Every enclosure we design is carefully crafted
to meet your dimensional requirements,
proto-typed and tested for fit and compliance
with relevant safety standards, fabricated
to exacting tolerances and finished to your
paint specification.
Return to the
Table of Contents
Benshaw and additional brands.
Integrated Machine Logic:
Integrated Power Packages:
Benshaw can supply standard or PC-based
programmable logic controllers, and will
custom design hardware or software to
meet process requirements.
Benshaw can also incorporate all of the
power distribution components needed
for your machine in one simple,
plug-and-play package.
Networking capabilities, remote monitoring
and custom designed human machine
interface packages are also available.
Turnkey power distribution packages typically
include all internal and external motor control
wiring harnesses, power wiring harnesses,
motor/machine sensor connections and,
if needed, a fully integrated power factor
correction unit.
Integrated Control Sensors:
Benshaw can integrate any number of sensors,
transducers, relays, switches, meters and
protective devices, as required, to precisely
monitor and respond to all critical process,
machine or environmental variables.
All power systems are factory tested
at Benshaw with custom-built machine
simulators and wire pull-testers to
guarantee reliable performance.
Typical OEM / Industrial Applications
• Air and process compressors
• Blowers and air handling equipment
• Chillers
• Conveyors
• Food / liquid processing equipment
• Industrial refrigeration equipment
• Municipal waste / water
handling machines
• Pumps
• Pipelines
• Shredders / grinders
• Specialty machinery
• Transfer lines
Let our knowledge become
your competitive edge.
Return to the
Table of Contents
2-53
Custom-engineered drive solutions.
For any drive application.
In any configuration.
Whether you need simple modifications made to one of Benshaw’s standard drive
packages, a custom engineered, application-specific drive package or a turnkey drive
solution, Benshaw can help.
With engineering experience and complete motor control system production
capabilities, Benshaw delivers all of the competence, convenience and value
you’d expect from a leader in engineered control systems.
Whatever your motor control needs may be, Benshaw’s engineering teams
and application specialists can help you find a cost-effective, reliable solution.
Quality assurance testing
Control Modifications:
Benshaw’s assembly teams perform a
preliminary quality assurance inspection
before delivery is made. Drive assemblies
undergo a variety of testing procedures,
including motor operation testing, load
testing, control circuit testing, wire pull
testing, electrical performance checks,
mechanical alignment inspection, torque
measurement and user interface /
pilot device functionality.
Over 250 control modifications
and accessories are available
from Benshaw, including:
All test processes meet or exceed ISO 9001
requirements, and all tests are documented
and archived for quality verification.
Enclosures:
• Standard NEMA 1, 12 and 3R
enclosure designs
• Custom enclosures
• NEMA 4, 4X, air conditioned
and other special enclosures
• Pilot devices
• Control power transformers
• Switches
• Meters
• Relays
• Space heaters
• Protective devices
• PLCs
Bypass Packages:
• Three contactor
• Reduced voltage solid state starters
Filters:
• Line reactors (3% and 5%)
• Motor control centers
• Long lead filters
• Combination drive packages
• Passive harmonic filters
• 15–2,000 A circuit breakers
• 18 pulse systems (IEEE-519)
• 40–2,000 A non-fused disconnects
• 30–800 A fusible disconnects
• Flange or rotary handle mechanisms
Benshaw delivers...no matter
what your motor control needs.
2-54
benshaw.com
Return to the
2-54
Table of Contents
Clean Power Drives
SG 519 Series
RATINGS
Standard Duty:
50–600 HP @ 460 V
IEEE-519 Compliant
Product Highlights:
Benshaw’s SG 519 Series drives are designed and manufactured to limit voltage and current
distortion levels to within the levels defined by IEEE-519*. This eliminates the need for
expensive, time consuming harmonic analysis and avoids the resonance problems associated
with inefficient harmonic filters.
Heavy Duty:
Our municipal projects and engineering team will work with you to configure a clean power
solution that meets your specifications and requirements.
50–500 HP @ 460 V
Modular Design:
The modular design of Benshaw’s SG 519 Series drives eliminates maintenance problems
inherent in older drive designs and improves drive reliability by significantly reducing power
module part counts. This design approach also allows each drive unit to be custom-tailored
to your specific requirements.
Optional Bypass:
An optional bypass design configuration (ATL or RVSS) is available for SG 519 drive
packages when mission critical reliability is important and disruptive downtime cannot
be tolerated.
Standard Features:
• SG Series drive
• NEMA 1 ventilated enclosure
• 65 kAIC circuit breaker with lockable disconnect
• Phase-shifting transformer and line reactor
• 12-pulse rectifier unit
• Control transformer with extra 120 V capacity
• Door-mounted control
• Keypad / display start / stop buttons
• Reset button hand-off-auto switch
• Speed potentiometer
Options
• Bypass (ATL or RVSS)
• Line fusing
• Output filter (reactor, long lead or sine wave)
• Enclosures — NEMA 12, 3R, 4 or 4X (with AC unit)
• RTD monitor
• Communications
• Control options to customer specification
* IEEE-519, 1992 Table 10-2 and Table 10-3.
Return to the
Table of Contents
2-55
Engineered Low
Voltage Drive Products
Clean Power Drives
Engineered Packages
Part Number Assembler
RSI
519
060
VFD
RSI
SG
4
NC
RediStart
Inverter
Horsepower
18 Pulse
519
=
SG
18 Pulse
050
=
50 HP
060
=
60 HP
075
=
75 HP
=
1/12
Package Type
VFD Series
=
A
Sensorless
Vector Drive
A
=
Packaged Drive,
No Bypass
C
=
Packaged Drive with
Three Contactor Bypass
SS
=
Packaged Drive with
Soft Starter (SS)
Bypass**
Voltage
4
=
460 V
100
=
100 HP
125
=
125 HP
Disconnect Options
Enclosure**
1/12
=
NEMA 1/12
4
=
NEMA 4*
3R
=
NEMA 3R
150
=
150 HP
NC
=
Non-Combination**
200
=
200 HP
CB
=
Circuit Breaker
(65 Kaic)
FD
=
Fusible Disconnect**
250
=
250 HP
300
=
300 HP
400
=
400 HP
500
=
500 HP
600
=
600 HP
700
=
700 HP
* Air conditioning required.
** Consult factory.
2-56
benshaw.com
Return to the
Table of Contents
Clean Power Drives
IEEE-519 460 V, SG Series, NEMA 1, No Bypass
Standard Duty
Heavy Duty
Dimensions (in.)
Model Number
HP
Amps
HP
Amps
H
W
D
List Price
RSI-519-050-SG-4-CB-A-01
50
65
40
52
90
36
30
$26,231.00
RSI-519-060-SG-4-CB-A-01
60
77
50
65
90
36
30
$28,226.00
RSI-519-075-SG-4-CB-A-01
75
96
60
77
90
36
30
$30,912.00
RSI-519-100-SG-4-CB-A-01
100
124
75
96
90
36
30
$32,230.00
RSI-519-125-SG-4-CB-A-01
125
156
100
124
90
36
30
$35,435.00
RSI-519-150-SG-4-CB-A-01
150
180
125
156
90
48
30
$41,818.00
RSI-519-200-SG-4-CB-A-01
200
240
150
180
90
48
30
$49,121.00
RSI-519-250-SG-4-CB-A-01
250
302
200
240
90
48
36
$52,583.00
RSI-519-300-SG-4-CB-A-01
300
361
250
302
90
78
36
$62,092.00
RSI-519-350-SG-4-CB-A-01
350
414
–
–
90
78
36
$65,675.00
RSI-519-400-SG-4-CB-A-01
400
477
300
361
90
78
36
$75,500.00
RSI-519-500-SG-4-CB-A-01
500
590
350
414
90
96
36
$95,639.00
RSI-519-600-SG-4-CB-A-01
600
720
400
477
90
96
36
$120,123.00
RSI-519-700-SG-4-CB-A-01
700
840
500
590
90
96
36
$130,631.00
IEEE-519 460 V, SG Series, NEMA 1, With Bypass (Three Contactor)
Standard Duty
Heavy Duty
Dimensions (in.)
Model Number
HP
Amps
HP
Amps
H
W
D
List Price
RSI-519-050-SG-4-CB-C-01
50
65
40
52
90
36
30
$26,582.00
RSI-519-060-SG-4-CB-C-01
60
77
50
65
90
36
30
$28,655.00
RSI-519-075-SG-4-CB-C-01
75
96
60
77
90
36
30
$31,352.00
RSI-519-100-SG-4-CB-C-01
100
124
75
96
90
48
30
$32,781.00
RSI-519-125-SG-4-CB-C-01
125
156
100
124
90
48
30
$36,569.00
RSI-519-150-SG-4-CB-C-01
150
180
125
156
90
54
30
$43,006.00
RSI-519-200-SG-4-CB-C-01
200
240
150
180
90
54
30
$50,609.00
RSI-519-250-SG-4-CB-C-01
250
302
200
240
90
78
36
$54,119.00
RSI-519-300-SG-4-CB-C-01
300
361
250
302
90
96
36
$63,790.00
RSI-519-350-SG-4-CB-C-01
350
414
–
–
90
96
36
$69,728.00
RSI-519-400-SG-4-CB-C-01
400
477
300
361
90
96
36
$79,553.00
RSI-519-500-SG-4-CB-C-01
500
590
350
414
90
96
36
$99,692.00
RSI-519-600-SG-4-CB-C-01
600
720
400
477
90
96
36
$124,319.00
RSI-519-700-SG-4-CB-C-01
700
840
500
590
90
96
36
$136,031.00
Return to the
Table of Contents
2-57
Engineered Low
Voltage Drive Products
Clean Power Drives
IEEE-519 460 V, SG Series, NEMA 1, With Bypass (RVSS)
Standard Duty
Heavy Duty
Dimensions (in.)*
Model Number
HP
Amps
HP
Amps
H
W
D
List Price
RSI-519-050-SG-4-SS-D-01
50
65
40
52
90
36
30
$27,572.00
RSI-519-060-SG-4-SS-D-01
60
77
50
65
90
36
30
$29,700.00
RSI-519-075-SG-4-SS-D-01
75
96
60
77
90
36
30
$32,559.00
RSI-519-100-SG-4-SS-D-01
100
124
75
96
90
48
30
$34,406.00
RSI-519-125-SG-4-SS-D-01
125
156
100
124
90
48
30
$38,300.00
RSI-519-150-SG-4-SS-D-01
150
180
125
156
90
54
30
$44,825.00
RSI-519-200-SG-4-SS-D-01
200
240
150
180
90
54
30
$52,634.00
RSI-519-250-SG-4-SS-D-01
250
302
200
240
90
78
36
$56,222.00
RSI-519-300-SG-4-SS-01
300
361
250
302
90
114
36
$69,584.00
RSI-519-350-SG-4-SS-D-01
350
414
–
–
90
114
36
$76,518.00
RSI-519-400-SG-4-SS-D-01
400
477
300
361
90
114
36
$86,341.00
RSI-519-500-SG-4-SS-D-01
500
590
350
414
90
132
36
$106,480.00
RSI-519-600-SG-4-SS-D-01
600
720
400
477
90
132
36
$131,455.00
RSI-519-700-SG-4-SS-D-01
700
840
500
590
90
132
36

* Enclosure Dimensions
Consult factory
Included in Standard Package:
Options
• SG Series VFD
• NEMA 12V, 3R, 4, 4X enclosures
• NEMA 1 ventilated enclosure
• Air conditioning
• Circuit breaker disconnect
• Input fusing
• 18 pulse transformer
• Output reactor
• Input line reactor
• Long lead filter
• Control transformer
• Input filter (in lieu of 18-pulse input)
• Door-Mounted Control devices (keypad, start / stop,
• Bypass (three contactor or RVSS)
reset, HOA switch, speed potentiometer)
• Control options to customer specification
• Communications
2-58
benshaw.com
Return to the
Table of Contents
Medium Voltage Starters
Standard Medium Voltage
Starter Products
Next Generation Intelligent
Motor Control.....................................3-2
Prepackaged Solid State Starters........3-4
Built-To-Order, Solid State
Reduced Voltage Starters................... 3-7
Build Your Customized Starter............3-8
Engineered-to-Order Capability.......3-10
Engineered Medium Voltage
Starter Products
Combination Solid State Starters...... 3-11
Medium Voltage Starter
Order Check List...............................3-16
Smart Full Voltage ATL Starters.........3-19
Full Voltage ATL Starters...................3-22
Main Lug Only...................................3-24
Load Interrupter Switch.....................3-26
Engineered Medium Voltage
Starter Options
Pilot Devices.....................................3-28
Control Options................................3-30
Motor Protective Relays.................... 3-31
Enclosure and Bus Options...............3-32
Power Factor Correction
Capacitors.........................................3-33
Surge / Lighting Arrestors.................3-34
Surge Capacitors...............................3-35
Line Reactors.....................................3-36
Documentation................................. 3-37
Wound Rotor Starters.......................3-38
Wound Rotor Motor Starter
Check List..........................................3-39
Synchronous Starters.........................3-40
Synchronous Motor Starter
Check List.......................................... 3-41
MX3 Intelligent Motor Control..........3-42
Mission Critical Reliability.................3-44
Return to the
Table of Contents
3-1
Standard Medium
Voltage Starter Products
Next Generation Intelligent Motor Control
MX 3 Controller
Fiber Optic SCR Firing
• Integrated technology
• Noise immunity
• High voltage isolation
• Safe, reliable SCR control
Product Highlights:
Next generation MX3 technology forms the backbone of Benshaw’s entire line of intelligent
medium voltage motor controls. With fiber optic firing, enhanced programming capabilities,
ease of use and a unique, flexible architecture, Benshaw’s MX3 controller delivers unprecedented
functionality and all of the rugged, dependable performance you’ve come to expect from a
world leader in solid state motor controls and drives.
MX3 controllers, power components, software and sensors are all designed, built and tested
to perform as an integrated control system, eliminating the coordination and performance
problems inherent in other forms of reduced voltage starting.
With more built-in features, more configurable options, greater expandability and a broader
communications capability than any other motor control on the market, Benshaw’s next
generation MX3 technology will shorten your commissioning times, improve motor performance
and protection, enhance diagnostic capability and streamline many electrical system monitoring
and maintenance tasks.
Key Features:
Keypad (Included)
• High performance motor control with multiple starting modes built in
• Flexible, programmable I/O
• Integrated motor protection
• Line and motor metering
• Diagnostic capabilities with event log and real-time clock
• Built-in remote self-testing (BIST)
• Expanded communications capabilities
• Intelligent SCR power poles
• Intelligent MV MCC integration
Optional RTD Modules
3-2
benshaw.com
Return to the
Table of Contents
Next Generation Intelligent Motor Control
MX 3 Controller
Control Features
Multiple Starting Modes:
• Voltage ramp
• Current ramp
–– Adjustable initial current
Metering:
• Accuracy:
8 Digital Inputs
Configurable to:
1 Analog 4 – 20 mA /
0 – 10 VDC Output
Configurable to:
–– 3% out-of-box
• Stop
–– 2% factory calibrated
• Fault
• Current (0 – 200%/0 – 800%)
–– Adjustable maximum
current
• Average current
• Fault reset
• Voltage (0 – 150%)
• L1 current
• Bypass / inline confirm
• OL (0 – 150%)
–– Adjustable ramp time
• L2 current
• OL reset
• kW (0 – 10 kW/0 – 100 kW)
• Torque ramp (TruTorque)
• L3 current
• Local / remote selection
• MW (0 – 1 MW)
–– Adjustable initial torque
• Current imbalance %
• Heater enable
• Analog input (0 – 100%)
–– Adjustable maximum
torque
• Ground fault current
• Heater disable
• Firing (0 – 100%)
• Average volts
• Dual ramp selection
• Calibration
• L1 – L2 voltage
• 1 dedicated start input
• L2 – L3 voltage
• Disconnect
• Event log (99 events)
• L3 – L1 voltage
• Slow speed
• Door mounted LCD display
• Overload %
• Brake enable
• Power factor
• Brake disable
–– Set / examine operating
parameters
6 Relay Outputs
Configurable to:
–– View status information,
line current, voltage
and frequency
–– Adjustable ramp time
• Power ramp
–– Adjustable initial torque
–– Adjustable maximum
torque
–– Adjustable ramp time
• Linear / tach feedback control
Motor Protection:
• Motor thermal overload
• Independent starting
• Watts
• VA
• VARS
• Faulted
• kW hours
• Running
User Interface:
–– Start and stop the
solid state starter
1 Communication Port:
• MW hours
• Up to speed
• Up to speed timer exceeded
• Phase order
• Alarm condition
• Low line voltage
• Line frequency
• Ready condition
• Low line frequency
• Analog input
• Locked out
• Dual ramp selection
• High line frequency
• Analog output
• Over current
• Adjustable kick current
• Phase reversal
• Run time — days
• Under current
• Programmable decel modes
• Phase loss
• Run time — hours
• OL alarm
• MV BIST test (built-in self test)
• Instantaneous overcurrent
• # of starts
• Shunt trip
• Overcurrent
• Tru Torque %
• Ground fault
• Undercurrent
• Power %
• Energy saver indication
• Current imbalance
• Peak starting current
• Heating indication
• Ground fault (residual
• Last starting duration
• Cooling fan
and running OLs
or zero sequence)
• Shorted or open SCR
• Disconnect fault
• Inline contactor fault
• Control power low
• Stack over temperature
• RTD temperatures
• Real-time clock
• ModBus / RS485
Advanced Functionality:
1 Analog 4 – 20 mA /
0 – 10 VDC Input
Configurable to:
• Trip high level
• Trip low level
• Motor PTC input
• RTD modules
Return to the
Table of Contents
3-3
Standard Medium
Voltage Starter Products
Prepackaged Solid State Starters
MVRXE Series
Emergency ATL Bypass, Severe Duty, Load Break
Fusible Disconnect
Product Highlights:
The Benshaw Medium Voltage Starter is a microprocessor controlled solid state
reduced voltage starter for three phase induction motors. The starter provides
a closed-loop current ramp for smooth stepless motor acceleration. Supplied
in a free standing enclosure.
Enclosures are available in NEMA 12 or NEMA 3R configurations. The medium voltage
enclosure consists of two distinct compartments. The medium voltage or power pole
section is located in the main body of the enclosure, whereas the low voltage section
containing the control logic is located behind the door as an isolated compartment.
Each starter is supplied with a load break isolation switch, Class "R" motor fuses, inline
vacuum contactor, solid state power poles and a vacuum bypass contactor, which is
used to bypass the SCR power poles once the motor is up to full speed.
The logic control incorporates the MX3 computer that has all the circuitry required
to drive the power semiconductors, which are located in the power section.
MVRXE starters provide solid state reduced voltage starting for normal operation
and full voltage emergency back-up starting, with complete electronic motor
protection at the flip of a switch.
This unique redundant design is ideal for critical applications where downtime
is extremely disruptive and cannot be tolerated.
MX3 solid state controls provide precise digital starting and stopping,
motor protection, metering, diagnostics and communications, standard.
Key Advantages:
• NEMA 12, UL 347 listed
• 45 kV BIL
• Service entrance labeled (optional)
• Built-in self test (BIST) features for "quick commissioning"
• Solid state reduced voltage starting — normal operations
• 425 A load break
• Switch selectable emergency back-up full voltage starter
• MX3-embedded digital control
• Fiber optic SCR firing
• Advanced motor protection
• Advanced metering
• Power quality protection
• Diagnostics and ModBus RTU485 communications standard
3-4
benshaw.com
Return to the
Table of Contents
Prepackaged Solid State Starters
Standard Features:
• NEMA 12, solid state starter, UL347 listed,
Class E-2
• 45 kV BIL
• 200 MVA (2300 VAC) / 350 MVA
(4160 VAC) short circuit fault rated
• 500% – 30 seconds rated solid state
starter — UL347 certified and listed
• 8,000 PIV — UL347 certified
and listed at 2.4 kV
• 12,000 PIV — UL347 certified
and listed at 4.2 kV
• Fixed mounted, start duty rated vacuum
contactors for isolation and SCR bypass,
wired for normal bypass operation and full
voltage start operation, with (2) N/O and
(2) N/C auxiliary contacts
• Separately mounted "SPE" series
electronic overload device has the
following standard features:
–– Class 10 – 30 adjustable
–– Phase imbalance protection
–– 1 NO / 1 NC trip contact
• Fiber optic SCR firing
–– Phase reversal protection
• Selectable solid state or emergency full
–– "Trip free" design
voltage operation via selector switch
mounted inside of LV compartment
• Load matched Class R fusing with blown
fuse indication
• 425 A load break, 5 kV rated disconnect
switch, with viewing window, grounding
assembly and lockable handle
mechanism; mechanically interlocked
for safety
• Door-mounted LCD keypad
• Door-mounted run indication light
• Door-mounted local-off-remote switch
• Door-mounted reset button
• Terminal strip mounted inside LV
compartment for:
–– Remote start / stop control
–– Remote up-to-speed indication
–– Remote run indication
–– Remote fault indication
• Benshaw MX3 controller with
complete soft start, soft stop
and motor protection capabilities
–– Phase loss protection
• Built-in self test (BIST) features
for "quick commissioning"
• 120 VAC, 1000 VA CPT with primary and
secondary fusing, with 500 VA available
for customer use
• 485 communications capabilities —
local through door connection
or remote from starter (optional)
• ModBus communications standard
• Door-mounted start and stop
push buttons
Benshaw MVRXE vs. Any Autotransformer Starter
Any Auto Transformer
Benshaw MVRXE
Soft Start
Motor Control & Protection Functions
Yes
Yes
Soft Stop
No
Yes
Full Voltage Bypass Starting
No
Yes
Load Break Disconnect Switch
No
Yes
Built-In Self Test
No
Yes
UL 347 / Service Entrance Rated (Optional)
No
Yes
3 Year Warranty
No
Yes
Plain English Digital Display
No
Yes
Electronic OL Protection
No
Yes
Electronic Power Quality
No
Yes
Digital Metering
No
Yes
Embedded Plain English Diagnostics
No
Yes
Embedded RS485
No
Yes
Incoming Line Landing Pad
No
Yes
Integrated Control & Protection
No
Yes
UL Zero Sequence Ground Fault *
No
Yes
* Optional ground fault CT required
Return to the
Table of Contents
3-5
Standard Medium
Voltage Starter Products
Prepackaged Solid State Starters
MVRXE Series
Emergency ATL Bypass, Load Break Fusible Disconnect
MVRXE18—4160 V
Dimensions (in.)
HP
A
H
W
D
Weight (lbs.)
NEMA 12
List Price
NEMA 3R
List Price
 MVRXE18-1000-4160 **
1000
133
92
36
32
2,000
$45,175.00
$48,150.00
 MVRXE18-1500-4160 **
1500
200
92
36
32
2,000
$45,750.00
$48,375.00
 MVRXE18-3000-4160 **
3000
330
92
36
32
2,000
$54,945.00
$57,995.00
Model Number
Starters are top entry / bottom exit — top exit available upon request. Dimensions and weights are approximate.
Available for same day shipping.
** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R

Web stocked
MVRXE12—2300 V
Dimensions (in.)
Model Number
HP
A
H
W
D
Weight
(lbs.)
NEMA 12
List Price
NEMA 3R
List Price
MVRXE12-550-2300 **
550
133
92
36
32
1,800
$41,495.00
$44,445.00
MVRXE12-750-2300 **
750
200
92
36
32
1,800
$42,895.00
$45,850.00
MVRXE12-1500-2300 **
1500
330
92
36
32
1,800
$48,750.00
$52,665.00
Starters are top entry / bottom exit — top exit available upon request. Dimensions and weights are approximate.
** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R
NOTE: Power fuses ship loose. Please provide motor full load amps at time of order for proper fuse sizing.
Please allow a 4 week lead time.
Modular Options
Model Number
Description
List Price
 A171
Space Heater with Thermostat (Included In NEMA 3R Option)
$495.00
 A008
E-Stop Push-Button, Mushroom Head, Red
$145.00
 A406
8-Channel RTD Module, 100 ohm Platinum (Also Available for Remote Mounting)
$2,850.00
 A407
16-Channel RTD Module(s), 100 ohm Platinum (Also Available for Remote Mounting)
$5,235.00
 A408 *
Top Hat Enclosure Module for Top Entry (18"H x 30"W x 20"D),
Top Left or Top Right Mounting, Accommodates Stress Cones
$2,395.00
 A409
Service Entrance Labeled
$885.00
 A106
Additional 1000 VA Control Power Transformer
$865.00
The MVRXE series was designed as an integrated package. Listed above are the available modular options.
For systems requiring more extensive requirements, please refer to the MV engineered section of the this catalog beginning on page 3-12.
Refer to MLO section beginning on page 3-24 for starters that require top/top or bottom/bottom entry/exit locations.
*
Top hat will ship loose for customer installation.
 Built-to-order: Please allow 2 weeks for shipment of complete MVRXE unit when ordering these options with a stock starter.
Protective Relay Options
Model Number
Description
A875
Ground Fault CT, 2000:1, 4.0:Dia. (For MX Use)
A876
Ground Fault CT, 2000:1, 8.13:Dia. (For MX3 Use)
3-6
List Price
3
benshaw.com
$795.00
$1,625.00
Return to the
Table of Contents
Built-To-Order, 2 Week Shipment
Solid State Reduced Voltage Starters
4,160 Volt
MVRMX Series
0–1,500 HP or
1,501–3,000 HP
Product Highlights:
Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product
options, and developed a modular architecture to offer those options most ordered on a BuiltTo-Order program. This has enabled us to offer you a customized product with a reduced lead
time. Our goal is to optimize our response to meet your mission critical application needs.
The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family
of Class E2 load break/combination solid state starters. This integrated design includes control
and power electronics, bypass and isolation contactors that reduce maintenance and operating
costs when compared to other methods.
Key Advantages:
Protect machinery from failure and excessive maintenance caused by mechanical shock
during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration
and controlled deceleration.
Protect electrical systems from disruptive voltage drops and power outages caused by
motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current
ramp during start up.
Protect mission critical motors from failure or unscheduled outages caused by machine or
electrical system faults. The RediStart MVRMX starter provides complete, high performance,
coordinated line monitoring, motor control and protection.
Protective Relay Options
Description
Specification
Starting Method
Closed Loop Current Control Ramp
Torque Ramp
Power Ramp (kW)
Voltage Ramp
Linear Accel / Tach Feedback
Power Ratings
Reference Table A (See page 3-9)
Control Input
120 VAC or Dry Contact, 2 or 3 Wire
Standard Insulation Test
2X Rated V + 2,000 V
Nominal Voltage Ratings
4.16 kV
Ambient Temperature
0 – 40° C to 3,300 ft.
Frequency Range
23–72 Hz on Control Board
Overall Efficiency (W / Bypass)
99.50%
Metering Functions
47 Parameters
Relay Outputs
24 Functions
Over / Under Voltage Protection
10 to 30%
Power Loss (W / Bypass)
<0.1 Watt/Amp/Phase
Transient Protection
DV/DT Circuits/Phase
PIV Ratings
4 kV: 12,000 V
SCR Firing Technique
Hard Gate Continuous Block
Fiber Optic Firing
Return to the
Table of Contents
Basic Impulse Level
45 kV
Short Circuit Current Rating
350 MVA
UL / CUL
Yes
3-7
Build your
customized starter!
Only one option can be selected from each group,
with the exception of the ‘Control Options’ section.
Choose Enclosure Options
Add the appropriate code for the options chosen
to the code string across the center of the page.
0 to 1,500 HP
A
Choose
Core
Unit
B
C
Choose
Motor
Current**
Choose
Exit/
Landing
Option***
12
NEMA 12
$0
SH
NEMA 12 with space heater
$650
3R
NEMA 3R with space heater
$1,250
A
B
C
MVB43
225
B
1,501 to 3,000 HP
A
B
C
Choose
Core
Unit
Choose
Motor
Current**
Choose
Exit/
Landing
Option***
025
T
$41,000
MVB43
025
T
025
B
$40,795
MVB43
025
B
$45,775
MVB41
025
C
$40,000
MVB43
025
C
$44,750
MVB41
045
T
$41,000
MVB43
045
T
$45,995
MVB41
045
B
$40,795
MVB43
045
B
$45,775
MVB41
045
C
$40,000
MVB43
045
C
$44,750
MVB41
055
T
$41,000
MVB43
055
T
$45,995
MVB41
055
B
$40,795
MVB43
055
B
$45,775
MVB41
055
C
$40,000
MVB43
055
C
$44,750
MVB41
080
T
$41,000
MVB43
080
T
$45,995
MVB41
080
B
$40,795
MVB43
080
B
$45,775
MVB41
080
C
$40,000
MVB43
080
C
$44,750
MVB41
090
T
$41,500
MVB43
090
T
$46,150
MVB41
090
B
$40,995
MVB43
090
B
$46,050
MVB41
090
C
$40,250
MVB43
090
C
$45,150
MVB41
133
T
$41,500
MVB43
133
T
$46,150
MVB41
133
B
$40,995
MVB43
133
B
$46,050
MVB41
133
C
$40,250
MVB43
133
C
$45,150
MVB41
170
T
$41,500
MVB43
170
T
$46,150
MVB41
170
B
$40,995
MVB43
170
B
$46,050
MVB41
170
C
$40,250
MVB43
170
C
$45,150
MVB43
225
T
$46,995
MVB43
225
B
$46,750
MVB43
225
C
$45,995
MVB43
330
T
$46,995
MVB43
330
B
$46,750
1N
S
Yes
$1,500
N
No
$0
$45,995
T
Top exit with landing pad
MVB43
330
C
$45,995
B
Bottom exit with landing pad
MVB43
360
T
$46,995
C
Top or bottom exit landing
on bypass contactor
MVB43
360
B
$46,750
MVB43
360
C
$45,995
benshaw.com
G
(for stand-alone single units)
MVB41
***Exit / Landing Options
S
Choose Service
Entrance Rated
MVB41
3-8
12
Choose Bus
Options+
0 to
1,500
HP
1,500
to
3,000
HP
8N
800 A
noninsulated
bus
$1,500
$1,750
8I
800 A
insulated
bus
$2,150
$2,195
1N
1,200 A
noninsulated
bus
$1,750
$1,850
1I
1,200 A
insulated
bus
$2,500
$2,555
2N
2,000 A
noninsulated
bus
$2,750
$2,795
2I
2,000 A
insulated
bus
$3,795
$3,850
NR
None
required
$0
$0
+Bus not required for single
stand-alone unit.
Bus is required for connection
of 2 or more units.
Any unit with bus will require additional
MLO section. Please contact the factory
for pricing and delivery.
Return to the
Table of Contents
Choose Communications Options
(RS-485 Modbus RTU standard)
Choose Option Zero Sequence
Ground Fault Ct 2000:1
(Residual included)
1N
D
DeviceNet
$1,500
E
Ethernet
$1,750
G
Yes
$750
P
Profibus
$2,250
N
No
$0
N
None
$0
D
2
D
E
F
G
H
I
N
B
N
N
E
E
Choose RTD Options
Choose Control Options —
(100 ohm platinum)
Choose one option for each item below
2
8-channel RTD
$2,850
D
A
ATL option*
D
N
None
$595
4
16-channel RTD
$5,235
E
B
E
N
None
$295
N
None
$0
Green start
push button
& red stop
extended
push button*
F
C
Red run light
& green stop
light
F
N
None
$295
G
D
Amber fault
light & black
reset push
button
G
N
None
$295
H
E
Local-offremote
3-position
switch
H
N
None
$175
I
F
Emergency
stop push
button
I
N
None
$185
Choose Bus Splice Options
(must match bus option selected)
8N
800 A non-insulated bus splice
$395
8I
800 A insulated bus splice
$625
1N
1,200 A non-insulated bus splice
$499
1I
1,200 A insulated bus splice
$725
2N
2,000 A non-insulated bus splice
$850
2I
2,000 A insulated bus splice
$1,050
NR
None required
$0
NEW
Optional
Safety
Feature:
Benshaw’s
answer to
remote
open/close
disconnect
ability.
Please
contact
factory and
reference
part number
EMO-425D
(Electric
Motor
Operator).
* Indicates ATL option comes with Start and Stop
Push Buttons i.e. Start Stop Push Buttons cannot
be selected.
No selection = keypad control.
Recommend ‘E’ stop option be selected.
**Motor currents vs. HP
are typical, confirm actual
motor current. Service
factor not accounted
for, adjust if required.
Table A
Motor A/HP
Starter Rating
Motor A/HP
Starter Rating
<25/200
500% for 30 sec.
<133/1000
500% for 30 sec.
<45/350
500% for 30 sec.
<170/1250
350% for 30 sec.
<55/400
500% for 30 sec.
<225/1700
500% for 30 sec.
<80/600
500% for 30 sec.
<330/2500
350% for 30 sec.
<90/700
500% for 30 sec.
<360/3000
350% for 30 sec.
Example: A 3,000 HP (MVB43), 225 A (225) unit with the following options: bottom exit w/landing pad (B), NEMA 12 Enclosure (12), Service
Entrance Rated (S), with Ground Fault (G), 1,200 A non-insulated bus (1N), 1,200 A non-insulated bus splice (1N), with DeviceNet (D), 8 channel
RTD (2), without ATL option (N), with start and stop buttons (B), without run and stop lights (N), without fault and reset lights (N), with a local-offremote switch (E), with emergency stop push button (F) would build the following code string: MVB43225B12SG1N1ND2NBNNEF
Return to the
Table of Contents
3-9
Engineered-to-Order Capability
Benshaw has developed advanced engineering, drafting, materials management
and quality systems focused on designing and building customer solutions. This
"Engineered-to-Order" capability, combined with an extensive inventory of control
components, protective relays, circuit breakers, contactors, enclosures and other
electrical / electronic devices, enables Benshaw to quickly ship engineered products.
Control Modifications — Whatever you specify
• Over 250 modifications and accessories are available, including: pilot devices,
communication, PLCs, control power transformers, switches, meters, relays,
space heaters, protective devices, power factor correction capacitors, surge
arrestors and line reactors
Combination Starters — To Meet Your Requirements:
• Solid state reduced voltage
• Standard full voltage
• Smart full voltage
• Solid state with full voltage bypass
Power Ratings — To Fit Your Application:
• 5 kV Class—10,000 HP
• 7.2 kV Class—30,000 HP
• 15 kV Class—30,000 HP
Enclosures — To Match Your Environment:
• Standard designs — NEMA 1, 12, 3R
• Custom enclosures
• Motor control centers
3-10 3-10
benshaw.com
benshaw.com
Return to the
Table of Contents
Engineered Medium Voltage Starter Products
Combination Solid State Starters
MVRMX Series
5 kV / 7.2 kV /
15 kV — Up to 30,000 HP
Product Highlights:
Only Benshaw has designed, built and supports more than 40,000 solid state starters, from
2,300 volts to 15 kV, for applications ranging from pumps, compressors and chillers to fans
and blowers, crushers, chippers and conveyors—for every motor type: induction, synchronous,
two-speed, reversing and wound rotor.
The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family
of Class E2 load break/combination solid state starters. This integrated design includes control
and power electronics, bypass and isolation contactors that reduce maintenance and operating
costs when compared to other methods.
Key Advantages:
Protect machinery from failure and excessive maintenance caused by mechanical shock
during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration
and controlled deceleration.
Protect electrical systems from disruptive voltage drops and power outages caused by motor
locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp
during start up.
Protect mission critical motors from failure or unscheduled outages caused by machine or
electrical system faults. The RediStart MVRMX starter provides complete, high performance,
coordinated line monitoring, motor control and protection.
Precision Engineered Products from Benshaw:
Rugged enclosures to
match your environment:
Specified control and
protective devices:
• NEMA 1
• Protective relays
• NEMA 12
• RTD monitors
• NEMA 12V
• Custom control / interface configuration
• NEMA 3R
• Marine duty
• Lineups
Specified bus configurations:
• Tin plated copper
• 800 / 1200 / 2000 A
• Top mount
• Environmentally or electrically insulated
• Pilot devices / PLCs
Specified surge capacitors
and lightning arrestors:
Benshaw will design and mount (as an
integrated unit) surge capacitors and lightning
arrestors to match your electrical system and
lightning protection requirements.
Load engineered power factor capacitors
and controls:
• Custom arrangements
• Start / run sequencing
• Higher BIL ratings available
• Load matching
• Front access copper ground bus
Return to the
Table of Contents
3-11
Engineered Medium
Voltage Starter Products
Combination Solid State Starters
MVRMX Series
5 kV / 7.2 kV / 15 kV — Up to 30,000 HP
Power Section Features:
Description
Specification
Starter Type
Closed Loop Current Control Ramp
Torque Ramp
Power Ramp (kW)
Voltage Ramp
Linear Accel / Tach Feedback
Power Ratings
350% to 500% FLA for 30 up to 90 Sec. 125% Cont.
Control Input
120 VAC or Dry Contact, 2 or 3 Wire
Standard Insulation Test
2X Rated V + 2,000 V
Nominal Voltage Ratings
2.3 kV to 13.8 kV
Ambient Temperature
0 – 40° C at Sea Level
Frequency Range
23 to 72 Hz on Control Board
Overall Efficiency (with Bypass)
99.50%
Metering Functions
47 Parameters
Relay Outputs
24 Functions
Over/Under Voltage Protection
10 to 30%
Power Loss (with Bypass)
<1.0 Watt / Amp / Phase
Transient Protection
DV/DT Circuits / Phase
PIV Ratings
2.4 kV:8000 V, 4.2 kV:12000 V
7.2 kV:18000 V, 13.8 kV:34500 V
SCR Firing Technique
Continuous Block Gate
Fiber Optic Firing
Status Display and Indicators:
LCD Status Display
LED Indicators
Each starter will have a keypad/display
assembly designed to:
The following LED indicators are provided
for advisory status and fault annunciation:
• Set or examine operating parameters
• Power ON
• Provide status information
• CPU heart beat
• Provide real-time information about line
• Communications
current, voltage and frequency
• Provide a means to start and
stop the solid state starter
3-12
benshaw.com
• RTD module
• Fiber optic firing
Return to the
Table of Contents
Combination Solid State Starters
MVRMX Series
2300 V
Dimensions (in.)
Model Number
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
V
HP
CFMVRMX12-150-2300 **
2300
150
36
92
36
32
$37,575.00
$39,850.00
CFMVRMX12-500-2300 **
2300
500
120
92
36
32
$37,575.00
$39,850.00
CFMVRMX12-750-2300 **
2300
750
180
92
36
32
$40,125.00
$42,395.00
CFMVRMX12-1000-2300 **
2300
1000
240
92
36
32
$41,235.00
$43,525.00
CFMVRMX12-1250-2300 **
2300
1250
300
92
36
32
$41,235.00
$43,525.00
CFMVRMX12-1500-2300 **
2300
1500
360
92
45
32
$42,250.00
$44,435.00
CFMVRMX12-HP-2300 **
2300
>1500
>360





3300 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMX12-300-3300 **
3300
300
51
92
36
32
$41,325.00
$43,895.00
CFMVRMX12-750-3300 **
3300
750
127
92
36
32
$41,325.00
$43,995.00
CFMVRMX12-1000-3300 **
3300
1000
169
92
36
32
$44,150.00
$46,635.00
CFMVRMX12-1250-3300 **
3300
1250
211
92
36
32
$45,355.00
$47,875.00
CFMVRMX12-1500-3300 **
3300
1500
254
92
36
32
$45,500.00
$47,995.00
CFMVRMX12-2000-3300 **
3300
2000
338
92
36
32
$46,375.00
$48,875.00
CFMVRMX12-HP-3300 **
3300
>2000
>338



Model Number


CFMVRMX series starters are complete combination E2 controllers. They include a load break / fault make disconnect switch, R rated current limiting motor
fuses, vacuum inline isolation contactor, SCR power stacks and microprocessor controls, CPT and vacuum bypass contactor. MVRMX non-combination starters
are available. Please contact the factory for pricing and application assistance.
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory
Return to the
Table of Contents
3-13
Engineered Medium
Voltage Starter Products
Combination Solid State Starters
MVRMX Series
4160 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMX18-300-4160 **
4160
300
40
92
36
32
$44,397.60
$46,670.00
CFMVRMX18-750-4160 **
4160
750
99
92
36
32
$44,475.60
$46,742.80
CFMVRMX18-1000-4160 **
4160
1000
133
92
36
32
$44,475.60
$46,742.80
CFMVRMX18-1250-4160 **
4160
1250
166
92
36
32
$44,475.60
$46,742.80
CFMVRMX18-1500-4160 **
4160
1500
200
92
36
32
$44,475.60
$46,742.80
CFMVRMX18-2000-4160 **
4160
2000
266
92
36
32
$53,336.40
$55,603.60
CFMVRMX18-2500-4160 **
4160
2500
333
92
36
32
$53,336.40
$55,603.60
CFMVRMX18-3000-4160 **
4160
3000
360
92
45
32
$54,132.00
$56,420.00
CFMVRMX18-3500-4160 **
4160
3500
466
92
96
36
$82,539.60
$84,812.00
CFMVRMX18-4000-4160 **
4160
4000
532
92
96
36
$82,539.60
$84,812.00
CFMVRMX18-4500-4160 **
4160
4500
600
92
96
36
$90,422.80
$92,690.00
CFMVRMX18-HP-4160 **
4160
>4500
>600



V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMX18-500-6900 **
6900
500
42
92
45
36
$74,438.00
$76,700.00
CFMVRMX18-750-6900 **
6900
750
63
92
45
36
$74,438.00
$76,700.00
CFMVRMX18-1000-6900 **
6900
1000
84
92
45
36
$74,438.00
$76,700.00
CFMVRMX18-1250-6900 **
6900
1250
105
92
45
36
$75,010.00
$77,272.00
CFMVRMX18-1500-6900 **
6900
1500
126
92
45
36
$75,010.00
$77,272.00
CFMVRMX18-2000-6900 **
6900
2000
168
92
45
36
$75,010.00
$77,272.00
CFMVRMX18-2500-6900 **
6900
2500
210
92
45
36
$75,800.40
$78,000.00
CFMVRMX18-3000-6900 **
6900
3000
252
92
45
36
$75,800.40
$78,000.00
CFMVRMX18-3500-6900 **
6900
3500
294†
92
45
36
$75,800.40
$78,000.00
CFMVRMX18-4000-6900 **
6900
4000
336
92
81
36
$115,000.00
$120,000.00
CFMVRMX18-4500-6900 **
6900
4500
378
92
81
36
$123,266.00
$125,528.00
CFMVRMX18-5000-6900 **
6900
5000
420
92
81
36
$123,266.00
$125,528.00
CFMVRMX18-5500-6900 **
6900
5500
462
92
81
36
$125,751.60
$128,024.00
CFMVRMX18-HP-6900 **
6900
>5500
>462†



Model Number


6900 V
Dimensions (in.)
Model Number


CFMVRMX series starters are complete combination E2 controllers. They include a load break / fault make disconnect switch, R rated current limiting motor fuses,
vacuum inline isolation contactor, SCR power stacks and microprocessor controls, CPT and vacuum bypass contactor. CPT is 700 VA standard (6,900 V). MVRMX
non-combination starters are available. Please contact the factory for pricing and application assistance.
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
† 350% for 30 sec. rated. 500% requires larger sizing. Please contact Benshaw.
Consult factory
3-14
benshaw.com
Return to the
Table of Contents
Combination Solid State Starters
15 kV Class
Common Voltages:
10 kV
11 kV
12.47 kV
13.2 kV
13.8 kV
Customized Entry/Exit:
MLOs
Cable Entry Top Hats
Optional Disconnect/
Fusing Input
Specified Controls
and Protection Devices:
Motor Protection Relays
Input Protection Relays
Lock-Out Relays
Custom Control/
Interface Configuration
Specialized Options:
Power Factor
Correction Capacitors
Lightning Arrestors
Surge Capacitors
Return to the
Table of Contents
Product Highlights:
Benshaw has designed, built and supported custom 15 kV class solutions for all applications and
motor types. Higher voltages bring greater safety concerns, and only Benshaw has over 15 years
of experience working with 15 kV class equipment. Whether the equipment is on an oil platform
or in a mine, Benshaw has experience with 15 kV class equipment all over the globe. Benshaw’s
15 kV class solutions come with standard MX3 technology that is known, qualified and respected
out in the field. Only Benshaw provides 15 kV solutions up to 30,000 HP.
Key Advantages:
Integrated line reactors within our solution. Higher voltages require more sophisticated
solutions, and only Benshaw provides line reactors that are integrated into all of our 15 kV
class solutions. Benshaw understands the complexities of working in the higher voltages,
and provides equipment reliable in running the most critical applications.
Full product portfolios. The heart of solid-state starting is in the power stacks, and Benshaw
has the knowledge and experience to understand the complexities of working in the higher
voltages. Benshaw has custom solutions for 10 kV, 11 kV and 13 kV class equipment, with each
solution consisting of a different design, number of required power electronics and fan cooling
if required. When you get a Benshaw 15 kV class starter, you know it will work in the most critical
applications, since it’s been designed for the environment.
Full solutions. Higher voltages require specialized equipment. Benshaw’s 15 kV class equipment
consists of either a load break disconnect, fusing and vacuum contactors or vacuum circuit
breakers for isolation and bypass. Benshaw has the experience and partners to design, develop
and ship a fully integrated solution to fit the application needs.
Engineered support from the quotation through the production cycle. Large critical motors
require higher voltage solutions. Benshaw understands that these applications require special
customized solutions, especially for the largest motors. Benshaw provides a team of engineers
to work closely with the end users to design a concept to meet our customer’s needs. Once
the order is received, Benshaw seamlessly transfers the solution to the production engineering
department to finalize the design. All of the up-front work saves the customer time and gives
them exactly what they need.
3-15
Engineered Medium
Voltage Starter Products
Medium Voltage Starter Order Check List
Medium Voltage Check List to assist in the engineering process of providing a properly manufactured Solid State Starter,
which will meet customer specific requirements. Complete each section as this will ensure a timely and accurate response.
Project Name and/or End-User__________________________________________________________
Contact Name________________________________________________________________________
Email_________________________________________________________________________________
Phone Number________________________________________________________________________
SECTION A — Starter Application
Type of
application
________________________________________________________________________________________________________________
Present starting
 Across the Line
method:
 Wye-Delta
 Auto Transformer
 Other: ______________________________________
Starts / Stops
per day:
 1–5
 6–10
 11–15
 16–20
 Over 20 (please specify)
__________________________
Current
Acceleration
Time
 1–5 seconds
 6–10 seconds
 11–15 seconds
 16–20 seconds
 >20 seconds (please specify)
__________________________
Current
Deceleration
Time (if
applicable)
 1–5 seconds
 6–10 seconds
 11–15 seconds
 16–20 seconds
 >20 seconds (please specify)
__________________________
Power source
 Utility (Transformer feed capacity – kVA) (please specify) _____________________________________________________________
 Short Circuit MVA (I) (please specify) ______________________________________________________________________________
 Delta
 Wye (please specify)
 3 wire
 4 wire
 Delta, Corner Grounded
 High resistance
ground
 Solid Ground
 Ungrounded
 Generator (Generator kW rating) (please specify) ___________________________________________________________________
Distance from
Line to starter:
 < 250 ft.
 251–500 ft.
Conductor
type:
 Shielded
 Non-Shielded
Distance from
Starter to
motor:
 < 250 ft.
Size and
Quantity of
Conductors:
3-16
 501–750 ft.
 > 750 ft. (please specify) ________________________
 251–500 ft.
 501–750 ft.
 > 750 ft. (please specify) ________________________
 Line Side Size:
______________________
 Line Side Quantity:
__________________/Phase
 Load Side Size:
______________________
 Load Side Quantity:
__________________/Phase
benshaw.com
Return to the
Table of Contents
Medium Voltage Starter Order Check List
SECTION B — Motor Data
Type of motor:
 Induction
Horsepower:
__________________
(If Synchronous or Wound Rotor, see Section “E” or “F” for additional questions.)
Motor voltage:
 2300
 4160
 6900
 13,800
Frequency:
 25 Hz
 50 Hz
 60 Hz
 Other: (please specify) ________________________
NEMA Design:
 “A”
 “B”
 “C”
 “D”
FLA: _________
Service Factor: ____
Motor LRA: ___________
Motor Speed (RPM): ____________
 Synchronous
 Wound Rotor
 Other: (please specify)
__________________________
 “E”
SECTION C — Enclosure / Environment Data
Expected
ambient
temperature:
Minimum: ________________________________
(Space Heater required if less than 0˚ C)
Maximum: ______________________________
Space heater:
 Yes
 No
Physical Location:
 Indoor
Size Limitation:
_______" High
_______" Wide
_______" Deep
( please indicate dimensions. )
Altitude:
 up to 3,300 ft.
 above 3,300 ft. (please specify) __________________________________
Excessive
Vibration and /
or Noise:
 Vibration
 Noise
 Neither
Color:
 ANSI 61 Grey
(standard)
 Beige
 Other: (please specify) _________________
Cable Entry
location:
 Top (option)
 Bottom (standard)
Cable Exit location:
 Top (standard)
 Bottom (option)
Horizontal Bus:
 NONE (standard)
 800 Amp
 1200 Amp
 2000 Amp
 Other: (please specify)
__________________________
Insulation
on Bus:
 Yes (price adder)
 No (standard)
UL Rating
(NEMA Type):
1
 3R
 12 (standard)
 Other: (please specify) ________________________
 Outdoor
SECTION D — Miscellaneous
Disconnect:
 Fusible Disconnect
Starting
Method:
 Keypad (standard)
 2-Wire Control
Across-theLine Starting
Option:
 Yes
 No (standard)
Will any of the
following be
present?:
Return to the
Table of Contents
 None
 Power Factor Correction Capacitors
Note: PFCC must be located on the Line side
of the Starter and must be isolated from the
line during starting.
 3-Wire Control
 Other: (please specify) ________________________
 Lightning Arrestors
Note: May be placed
on either the Line or
Load side of the Starter.
 Surge Capacitors
Note: Must be at the motor terminals and must be isolated
during starting to prevent damage.
3-17
Engineered Medium
Voltage Starter Products
Medium Voltage Starter Order Check List
SECTION E — Synchronous Motor Data:
Normal Field
Current: (ADC)
_________________
Max Field Current: (ADC)
_________________
Field Discharge
Resistor Rating:
_________________
Synchronous Motor Field
Voltage: (VDC)
_________________
SECTION F — Wound Rotor Motor Data:
Wound Rotor
Motor:
 Starting Duty Resistor
 Continuous Running Duty Resistor
Quantity
of Steps/
Resistance:
_________________
Present number of steps:
_________________
Secondary
Voltage: (VAC)
_________________
Secondary Current:
(Amps)
_________________
SECTION G — Additional Modifications, Accessories and/or Information:
________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________
Customer’s Signature __________________________________________________________
Customer’s Company __________________________________________________________
Date ______________________________
3-18
benshaw.com
Return to the
Table of Contents
Smart Full Voltage ATL Starters
CFMVRMXATL
Series
Product Highlights:
The "Smart" Medium Voltage "ATL" package includes the addition of the RediStart MX3 control
package for additional branch circuit monitoring motor protection, metering, diagnostics and
communication. Refer to MVRMX RediStart MX3 specification for complete details. A sampling
of the enhanced features includes:
Protection (ANSI standard numbers given)
• 51—Electronic motor overload, class 1 to 40
• 86—Overload lockout
• 59/27—Adjustable over / under voltage protection
• 46—Adjustable line to average current imbalance
• 81—Adjustable high and low frequency protection
• Single phase protection
• 66—Adjustable starts per hour (off or 1 to 20 starts)
• Adjustable time between starts (off or 1 to 600 minutes)
• Backspin timer (off or 1 to 200 minutes)
• 51—Overcurrent detection (off or 50 to 800%) and time (0.1 to 90.0
sec. in 0.1 sec. intervals)
• 37—Undercurrent detection (off or 10 to 100% and time (0.1 to 90.0
sec. in 0.1 sec. intervals)
• 51G—Ground fault detection (off or 1 to 100 amps) and time (0.1 to 90.0 sec.
in 0.1 sec. intervals)
• Overcurrent, undercurrent and ground fault can each be set to trip or activate a relay
• 50—Instantaneous electronic overcurrent trip
• 47—Phase rotation selectable ABC, CBA or Ins (insensitive)
• 38/49—Remote mountable RTD protection package, 8 or 16 RTD inputs (optional)
Control
• Local start / stop controls
• Emergency reset capability
Input / Output and Display
• Plain English operation via back lit LCD display interface
• LCD and LED status and diagnostics (full fault annunciation)
• Programmable metering (amps, volts, frequency, overload, power factor, elapsed time,
watts, VARs, watt hours, VA, current imbalance, ground fault current, RTD temperatures
with optional RTD module)
• Programmable relay outputs
• Latched fault relay output
• Real time clock
• Time stamped event recorder
• Password protection
• Battery backed-up starter parameters and lockout times
Return to the
Table of Contents
3-19
Engineered Medium
Voltage Starter Products
Smart Full Voltage ATL Starters
CFMVRMXATL Series
MX3 Control Features (Smart Across the Line)
Motor Protection:
Metering, continued:
1 Analog 4–20 mA / 0-10 VDC
Input Configurable to:
• Motor thermal overload
• kW hours
• Independent starting and
• MW hours
• Trip high level
• Phase order
• Trip low level
running OLs
• Low line voltage
• Low line frequency
• High line frequency
• Phase reversal
• Phase loss
• Instantaneous overcurrent
• Overcurrent
• Undercurrent
• Current imbalance
• Ground fault
(residual or zero sequence)
• Disconnect fault
• Inline contactor fault
• Control power low
• Line frequency
• Analog input
1 Analog 4–20 mA / 0-10 VDC
Output Configurable to:
• Analog output
• Current (0–200%/0–800%)
• Run time—days
• Voltage (0–150%)
• Run time—hours
• OL (0–150%)
• # of starts
• kW (0–10 kW/0–100 kW)
• TruTorque %
• MW (0–1 MW)
• Power %
• Analog input (0–100%)
• Peak starting current
• Firing (0–100%)
• Last starting duration
• Calibration
™
• RTD temperatures
• Real-time clock
8 Digital Inputs Configurable to:
User Interface:
• Event log (99 events)
• Door mounted LCD display
• Motor PTC input
• Stop
–– Set / examine operating parameters
• RTD modules
• Fault
–– View status information, line current,
voltage and frequency
• Fault reset
Metering:
• Accuracy:
–– 3% out-of-box
–– 2% factory calibrated
• Average current
• L1 current
• L2 current
• Bypass / inline confirm
• OL reset
• Local / remote selection
• ModBus / RS485
• Disconnect
6 Relay Outputs Configurable to:
• Faulted
• Current imbalance %
• Running
• Ground fault current
• Up to speed
• Average volts
• Alarm condition
• L1–L2 voltage
• Ready condition
• L2–L3 voltage
• Locked out
• L3–L1 voltage
• Over current
• Overload %
• Under current
• Power factor
• OL alarm
• Watts
• Shunt trip
• VA
• Ground fault
• VARS
• Cooling fan
benshaw.com
1 Communication Port:
• 1 dedicated start input
• L3 current
3-20
–– Start and stop the starter
Return to the
Table of Contents
Smart Full Voltage ATL Starters
CFMVRMXATL Series
2300 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMXATL-500-2300 **
2300
500
120
92
24
32
$18,750.00
$20,955.00
CFMVRMXATL-1000-2300 **
2300
1000
240
92
24
32
$19,650.00
$21,875.00
CFMVRMXATL-1500-2300 **
2300
1500
360
92
24
32
$20,995.00
$23,250.00
CFRMVRMXATL-HP-2300 **
2300
>1500
>360



Model Number


3300 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMXATL-1000-3300 **
3300
1000
169
92
24
32
$18,875.00
$21,250.00
CFMVRMXATL-1250-3300 **
3300
1250
211
92
24
32
$20,500.00
$22,750.00
CFMVRMXATL-1500-3300 **
3300
1500
254
92
24
32
$20,995.00
$23,250.00
CFMVRMXATL-2000-3300 **
3300
2000
338
92
24
32
$20,995.00
$23,250.00
CFMVRMXATL-2250-3300 **
3300
2250
380
92
60
36
$41,555.00
$43,895.00
CFMVRMXATL-2500-3300 **
3300
2500
423
92
60
36
$41,555.00
$43,895.00
CFRMVRMXATL-HP-3300 **
3300
>2500
>423



V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMXATL-1000-4160 **
4160
1000
133
92
24
32
$19,250.00
$22,250.00
CFMVRMXATL-2000-4160 **
4160
2000
266
92
24
32
$19,750.00
$22,750.00
CFMVRMXATL-2500-4160 **
4160
2500
333
92
24
32
$20,525.00
$23,650.00
CFMVRMXATL-3000-4160 **
4160
3000
399
92
60
36
$39,995.00
$43,995.00
CFRMVRMXATL-HP-4160 **
4160
>3000
>399



Model Number


4160 V
Dimensions (in.)
Model Number


6900 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVRMXATL-1500-6900 **
6900
1500
125
92
24
32
$21,250.00
$24,550.00
CFMVRMXATL-2250-6900 **
6900
2250
187
92
24
32
$23,150.00
$25,375.00
CFMVRMXATL-4000-6900 **
6900
4000
332
92
24
32
$23,650.00
$25,875.00
CFRMVRMXATL-HP-6900 **
6900
>4000
>332



Model Number


** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory
OTHER VOLTAGES AVAILABLE — PLEASE INQUIRE
Return to the
Table of Contents
3-21
Engineered Medium
Voltage Starter Products
Full Voltage ATL Starters
CFMVATL Series
Product Highlights:
CFMVATL medium voltage across-the-line starters are full voltage controllers for three
phase induction motors. The RediStart MX3 control package can be added as an
option to provide a "Smart" CFMVRMXATL package.
Combination CFMVATL starters are supplied in a free standing enclosure. Enclosures
are available in NEMA 1, NEMA 12 and NEMA 3R configurations. Enclosure consists of
two distinct compartments. The medium voltage section is located in the main body
of the enclosure, and the low voltage section containing the control logic is located
behind the door in an isolated compartment.
Standard combination CFMVATL starters are supplied with a load break / fault make
disconnect isolation switch, Class "R" motor current limiting fuses, vacuum motor
starting contactor and the "SPE" SureProtex electronic overload protection. Refer to
the CFMVRMXATL series for the RediStart MX3 control package for additional branch
circuit monitoring, motor protection, metering, diagnostics and communication.
Standard Features:
The standard medium voltage combination "ATL" package includes:
• NEMA 1,12, 3R enclosure
• Disconnect switch
–– Load break / fault make
–– Grounding bar
–– Viewing window
• Motor fusing
–– Class "R"
–– Current limiting
• Vacuum motor starting contactor
• Start / stop push-buttons
• "SPE" overload protection
–– Class 10-30 adjustable
–– 1 N/O, 1 N/C trip contact
–– "Trip free" design
–– Phase imbalance protection
–– Phase reversal protection
–– Phase loss protection
–– Test function / trip indication
–– Fault indication
3-22
benshaw.com
Return to the
Table of Contents
Full Voltage ATL Starters
2300 V
Dimensions (in.)
Model Number
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVATL-500-2300 **
2300
500
120
92
24
32
$14,000.00
$16,885.00
CFMVATL-1000-2300 **
2300
1000
240
92
24
32
$16,500.00
$18,650.00
CFMVATL-1500-2300 **
2300
1500
360
92
24
32
$17,500.00
$19,850.00
CFMVATL-HP-2300 **
2300
>1500
>360





3300 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVATL-1000-3300 **
3300
1000
169
92
24
32
$14,850.00
$17,000.00
CFMVATL-1250-3300 **
3300
1250
211
92
24
32
$15,500.00
$17,765.00
CFMVATL-1500-3300 **
3300
1500
254
92
24
32
$16,855.00
$17,995.00
CFMVATL-2000-3300 **
3300
2000
338
92
24
32
$17,000.00
$19,150.00
CFMVATL-2250-3300 **
3300
2250
380
92
60
36
$37,450.00
$39,735.00
CFMVATL-2500-3300 **
3300
2500
423
92
60
36
$37,500.00
$37,750.00
CFMVATL-HP-3300 **
3300
>2500
>423





V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVATL-1000-4160 **
4160
1000
133
92
24
32
$15,825.00
$18,000.00
CFMVATL-2000-4160 **
4160
2000
266
92
24
32
$16,365.00
$18,625.00
CFMVATL-2500-4160 **
4160
2500
333
92
24
32
$17,250.00
$19,500.00
CFMVATL-3000-4160 **
4160
3000
399
92
60
36
$37,475.00
$39,750.00
CFMVATL-HP-4160 **
4160
>3000
>399





Model Number
4160 V
Dimensions (in.)
Model Number
6900 V
Dimensions (in.)
V
HP
FLA
H
W
D
NEMA 1/12
List Price
NEMA 3R
List Price
CFMVATL-1500-6900 **
6900
1500
125
92
24
32
$18,175.00
$20,455.00
CFMVATL-2250-6900 **
6900
2250
187
92
24
32
$18,985.00
$21,250.00
CFMVATL-4000-6900 **
6900
4000
332
92
24
32
$19,500.00
$21,775.00
CFMVATL-HP-6900 **
6900
>4000
>332





Model Number
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory
OTHER VOLTAGES AVAILABLE — PLEASE INQUIRE
Return to the
Table of Contents
3-23
Engineered Medium
Voltage Starter Products
Main Lug Only
MLO Series
NEMA 1 / NEMA 12
Product Highlights:
Benshaw’s Main Lug Only (MLO) section provides a full height and depth NEMA rated
enclosure for use as a convenient area to land the line or load cable connections while
providing a transition area for a disconnect switch, starter or an MCC.
The MLO can be configured for top or bottom cable access (specify when ordering).
Customized MLO sections are available—just contact Benshaw’s factory with
your requirements.
Key Advantages:
• Landing pad for input cable
• Optional feed through bus to Benshaw line up
• Top or bottom cable entry
• NEMA 1, 12 or 3R enclosure configurations
• Transition from other manufacturers’ line up (optional)
• Configure to match up to existing bus network (optional)
• Optional control transformers and metering can be added
Standard Features:
• Landing pad for cabling
• NEMA 1/12 construction
• ANSI 61 grey
• 11 gauge steel construction
• Super durable polyurethane TGIC powder paint
• Tin plated copper bus
• Paint finish meets ASTM A252-9 or A525-83
• UL listed 5 kV Class
Options:
• Bus entry, left or right
3-24
benshaw.com
Return to the
Table of Contents
Main Lug Only
2300 V / NEMA 1/12/3R
NEMA 1/12
List Price
NEMA 3R
List Price
800 Amp Pull Section 18" Wide Enclosure
$7,350.00
$7,725.00
1200 Amp Pull Section 18" Wide Enclosure
$7,875.00
$8,295.00
MV-MLO-18-2000-2300*
2000 Amp Pull Section 18" Wide Enclosure
$8,150.00
$8,545.00
MV-MLO-24-800-2300*
800 Amp Pull Section 24" Wide Enclosure
$7,925.00
$8,325.00
MV-MLO-24-1200-2300*
1200 Amp Pull Section 24" Wide Enclosure
$8,500.00
$8,925.00
MV-MLO-24-2000-2300*
2000 Amp Pull Section 24" Wide Enclosure
$8,725.00
$9,155.00
NEMA 1/12
List Price
NEMA 3R
List Price
Model Number
Description
MV-MLO-18-800-2300*
MV-MLO-18-1200-2300*
3300 V / NEMA 1/12/3R
Model Number
Description
MV-MLO-18-800-3300*
800 Amp Pull Section 18" Wide Enclosure
$7,350.00
$7,725.00
MV-MLO-18-1200-3300*
1200 Amp Pull Section 18" Wide Enclosure
$7,875.00
$8,295.00
MV-MLO-18-2000-3300*
2000 Amp Pull Section 18" Wide Enclosure
$8,150.00
$8,545.00
MV-MLO-24-800-3300*
800 Amp Pull Section 24" Wide Enclosure
$7,925.00
$8,325.00
MV-MLO-24-1200-3300*
1200 Amp Pull Section 24" Wide Enclosure
$8,500.00
$8,925.00
MV-MLO-24-2000-3300*
2000 Amp Pull Section 24" Wide Enclosure
$8,725.00
$9,155.00
4160 V / NEMA 1/12/3R
NEMA 1/12
List Price
NEMA 3R
List Price
800 Amp Pull Section 18" Wide Enclosure
$7,350.00
$7,725.00
MV-MLO-18-1200-4160*
1200 Amp Pull Section 18" Wide Enclosure
$7,875.00
$8,295.00
MV-MLO-18-2000-4160*
2000 Amp Pull Section 18" Wide Enclosure
$8,150.00
$8,545.00
MV-MLO-24-800-4160*
800 Amp Pull Section 24" Wide Enclosure
$7,925.00
$8,325.00
MV-MLO-24-1200-4160*
1200 Amp Pull Section 24" Wide Enclosure
$8,500.00
$8,925.00
MV-MLO-24-2000-4160*
2000 Amp Pull Section 24" Wide Enclosure
$8,725.00
$9,155.00
NEMA 1/12
List Price
NEMA 3R
List Price
Model Number
Description
MV-MLO-18-800-4160*
6900 V / NEMA 1/12/3R
Model Number
Description
MV-MLO-18-800-6900*
800 Amp Pull Section 18" Wide Enclosure
$7,350.00
$7,725.00
MV-MLO-18-1200-6900*
1200 Amp Pull Section 18" Wide Enclosure
$7,875.00
$8,295.00
MV-MLO-18-2000-6900*
2000 Amp Pull Section 18" Wide Enclosure
$8,150.00
$8,545.00
MV-MLO-24-800-6900*
800 Amp Pull Section 24" Wide Enclosure
$7,925.00
$8,325.00
MV-MLO-24-1200-6900*
1200 Amp Pull Section 24" Wide Enclosure
$8,500.00
$8,925.00
MV-MLO-24-2000-6900*
2000 Amp Pull Section 24" Wide Enclosure
$8,725.00
$9,155.00
*Complete model number by adding suffix to specify NEMA 1, 12 or 3R enclosure: -1, -12 or -3R.
OTHER VOLTAGES AVAILABLE — PLEASE INQUIRE
Return to the
Table of Contents
3-25
Engineered Medium
Voltage Starter Products
Load Interrupter Switch
CFMVDISC Series
Product Highlights:
Benshaw’s free standing medium voltage load break interrupter switch is the latest design in
medium voltage high current switching equipment for a wide range of applications. The fused
interrupter switch provides an economical means of disconnect and short circuit protection of
medium voltage loads such as transformers, single circuit or multi-circuit systems.
The switch is provided in a NEMA 12 rated enclosure configured for use as a standalone unit,
in an equipment line-up or MCC.
Key Advantages:
• Bolts directly to Benshaw MCC line-up or starter
• UL labeled up to 4800 volts
• Available in 400, 600 and 1200 amp ratings
• Available up to 6600 volts
• Class E fusing included
• Configurable with added options
• Load break rated
Standard Features:
• Load break fault make
• 60 kV BIL up to 7.2 kV
• Symmetric fault ratings of 50 kA for 5 kV–7.2 kV and 45 kA for 2.4 kV
• NEMA 12 enclosure
• Viewing window to verify switch position
• Enclosure MV door interlocked with switch mechanism to prevent
access while switch is on
• Operating mechanism lockable in the off position
• Load side grounding in off position
• Blown fuse indication
• Welded 11 gauge steel construction
• Enclosure finish meets ASTM A252-9 or A525-83, G-90 designation
• Line and load landing pads with NEMA bolt pattern
Options:
• Lockable front panel
• Bus entry, left or right
3-26
benshaw.com
Return to the
Table of Contents
Load Interrupter Switch
CFMVDISC Series
2300 V
Dimensions (in.)
Model Number
Description
H
W
D
List Price
CFMV-DISC-24-400-2300-12 *
MV Disc Switch 400A 2300V Top Entry / Bottom Exit
92
24
30
$17,250.00
CFMV-DISC-36-600-2300-12 *
MV Disc Switch 600A 2300V Bottom Entry / Top Exit
92
36
36
$25,955.00
CFMV-DISC-36-1200-2300-12 *
MV Disc Switch 1200A 2300V Bottom Entry / Top Exit
92
36
36
$27,750.00
D
List Price
3300 V
Dimensions (in.)
Model Number
Description
H
W
CFMV-DISC-24-400-3300-12 *
MV Disc Switch 400A 3300V Top Entry / Bottom Exit
92
24
30
$17,250.00
CFMV-DISC-36-600-3300-12 *
MV Disc Switch 600A 3300V Bottom Entry / Top Exit
92
36
36
$25,955.00
CFMV-DISC-36-1200-3300-12 *
MV Disc Switch 1200A 3300V Bottom Entry / Top Exit
92
36
36
$27,750.00
Model Number
Description
H
W
D
List Price
CFMV-DISC-24-400-4160-12 *
MV Disc Switch 400A 4160V Top Entry / Bottom Exit
92
24
30
$17,250.00
CFMV-DISC-36-600-4160-12 *
MV Disc Switch 600A 4160V Bottom Entry / Top Exit
92
36
36
$25,955.00
CFMV-DISC-36-1200-4160-12 *
MV Disc Switch 1200A 4160V Bottom Entry / Top Exit
92
36
36
$27,750.00
Model Number
Description
H
W
D
List Price
CFMV-DISC-24-400-6600-12 **
MV Disc Switch 400A 6600V Top Entry / Bottom Exit
92
24
30
$18,250.00
CFMV-DISC-36-600-6600-12 **
MV Disc Switch 600A 6600V Bottom Entry / Top Exit
92
36
36
$33,500.00
CFMV-DISC-36-1200-6600-12 **
MV Disc Switch 1200A 6600V Bottom Entry / Top Exit
92
36
36
$41,650.00
4160 V
Dimensions (in.)
6600 V
Dimensions (in.)
See page 3-35 for available options. Options include horizontal bus, kirk key interlock and Main Lug Only (MLO) sections.
* For use on motor load Class R fuse will be provided and must be specified by customer.
** Non UL listed disconnect switch.
OTHER VOLTAGES AVAILABLE — PLEASE INQUIRE
Return to the
Table of Contents
3-27
Engineered Medium
Voltage Starter Options
Pilot Devices
Push-Buttons
Option Code
Description
A001
Raised Stop Push-Button - Red
List Price
$100.00
A002
Flush Start Push-Button - Green
$100.00
A003
Jog Push-Button - Yellow
$100.00
A004
OL Reset Push-Button - (For External OL Relay) - Black
$100.00
A005
Reset Push-Button - Black
$100.00
A006
Raised Push-Button - Specify Color And Function
$100.00
A007
Flush Push-Button - Specify Color And Function
$100.00
A008
Mushroom Head Stop Push-Button - Red
$150.00
A009
Illuminated Push-Button - Specify Color And Function
$175.00
Pilot Lights
Option Code
Description
A021
Red Run Light
$125.00
A022
Green Stop Light
$125.00
A023
Amber Fault Light
$125.00
A024
Green Ready Light
$125.00
A025
Amber Bypass Light
$125.00
A026
Red Light - Specify Function
$125.00
A027
Green Light - Specify Function
$125.00
A028
Amber Light - Specify Function
$125.00
A029
White Light - Specify Function
$125.00
A030
Blue Light - Specify Function
$125.00
A031
Push To Test Contact Assembly (Addition to Above)
$200.00
3-28
benshaw.com
List Price
Return to the
Table of Contents
Pilot Devices
Selector Switches
Option Code
Description
A041
Hand - Off - Auto Selector Switch
List Price
$175.00
A042
Local - Off - Remote Selector Switch
$175.00
A043
Key-Operated Hand - Off - Auto Selector Switch
$150.00
A044
Dual Ramps Selector Switch
$150.00
A045
Two-Postion Selector Switch - Specify Function
$200.00
A046
Three-Position Selector Switch - Specify Function
$200.00
A047
Other Selector Switch - Specify Function and Type

Consult factory
Meters
Option Code
Description
List Price
A061
Single-Phase Analog Ammeter - Includes CTs *
$1,200.00
A062
Analog Ammeter with Three-Phase Selector Switch - Includes CTs *
$1,500.00
A065
Elapsed Time Meter
$250.00
A066
Operations Counter
$250.00
A069
Other Power Metering - Specify Function
A075
Analog Voltmeter, Single Phase *
$3,500.00
$3,750.00

A076
Analog Voltmeter with Three-Phase Selector Switch *
A077
AC Wattmeter

A078
AC Watt Hour Meter

* Switchboard type
Consult factory
Return to the
Table of Contents
3-29
Engineered Medium
Voltage Starter Options
Control Options
MX3 Options
Option Code
Description
A401
Door Mounted Communications Package - Includes Door Mounted Connector and RS232 / 485 Card
List Price
$650.00
MXCOMPA343
Profibus Communications Bridge

MXCOMEA345
Ethernet Communications Bridge

MXCOMDA344
DeviceNet Communications Bridge
A405
Power Outage Ride-Thru - This Option Allows the Starter to Automatically Restart after a Power Loss
of up to 30 Secs. Customer Must Supply Separate Source of Uninterrupted 120 V to the Starter
$500.00
A406
RTD Module - Unit Will Accept 8 Input RTDs. RTDs must be 100 ohm Platinum. (Available for Remote
Mounting; Consult Factory for Details)
$3,000.00
A407
RTD Module - Unit Will Accept 16 Input RTDs. RTDs must be 100 ohm Platinum. (Available for Remote
Mounting; Consult Factory for Details)
$5,000.00
A411
1000 VA UPS / 700 W for 120V Supply Instead of Customer Supplied for Option A405 Power Outage
Ride-Thru
$3,000.00

Consult factory
Emergency Start Options
Option Code
Description
List Price
A410
Emergency / Across the Line Bypass Option, Includes Start / Stop Push-Buttons, Overload Relay
and Current Transformers and Selector Switch
$1,500.00
Consult factory
Control Power Transformers
Option Code
Description
List Price
A105
500 VA Additional Control Power
$725.00
A106
1000 VA Additional Control Power
$850.00
A107
Specify Control Power Amount
A110
1500 VA Additional Control Power
$2,000.00
A111
2500 VA Additional Control Power
$2,500.00

Consult factory
General Purpose Control Relays
Option Code
Description
List Price
A121
Three-Pole Relay - Specify Function
$225.00
A122
Four-Pole Relay - Specify Function
$275.00
A123
Other Relays - Specify Function and Type
A124
On Delay Timer - Specify Function and Time
$300.00
A125
Off Delay Timer - Specify Function and Time
$300.00
A126
Other Timers - Specify Function and Time
A127
Ground Fault Relay - For Equipment Protection Only
$1,500.00
Option Code
Description
List Price
A141
Transducer Output 0–5 VDC Based on Motor FLA
$650.00
A142
Transducer Output 4–20 mA Based on Motor FLA
$650.00
A145
Transducer Output 4–20 mA Based on Motor Voltage


Consult factory
Transducers

Consult factory
3-30
benshaw.com
Return to the
Table of Contents
Motor Protective Relays
The following protective relays include the necessary current and potential transformers included.
For optional zero sequence ground fault sensing, the appropriate current transformer should be added. Protective Relays
Option Code
Description
A826
Multilin 369 with RTD, Metering and Communications Options
List Price

A827
Multilin 469

A829
Multilin PQM II with Analog Output Options

A830
Cutler Hammer MP4000

A831
Schweitzer SEL 710

A832
Schweitzer SEL 749M

A838
Other

Consult factory
Protective Relay Options
Option Code
Description
A875
Ground Fault CT, 2000:1, 4.0:Dia. (For MX3 Use)
A876
Ground Fault CT, 2000:1, 8.13:Dia. (For MX Use)
Return to the
Table of Contents
List Price
3
$350.00
$1,000.00
3-31
Engineered Medium
Voltage Starter Options
Enclosure and Bus Options
Enclosure Options
Option Code
Description
A171
Space Heater With Thermostat
List Price
$450.00
A251
Door Interlock Switch
$275.00
A252
Single Key Kirk Key Interlock
$650.00
A255
Multiple Enclosure Mechanical Door Interlock
A256
Enclosure Upsizing - 24" W to 36" W
$1,000.00
A257
Enclosure Upsizing - 36" W to 45" W
$1,000.00
A258
Enclosure Upsizing - 32" D to 36" D
$1,000.00

Consult factory
Bus Splice Options (must match bus option selected)
Option Code
Description
8N
800 A Non-Insulated Bus Splice
$395.00
8I
800 A Insulated Bus Splice
$625.00
1N
1,200 A Non-Insulated Bus Splice
$499.00
1I
1,200 A Insulated Bus Splice
$725.00
2N
2,000 A Non-Insulated Bus Splice
$850.00
2I
2,000 A Insulated Bus Splice
NR
None Required
List Price
$1,050.00
$0
Bus Options*
Option Code
Description
0 to 1,500 HP
1,500 to 3,000 HP
8N
8I
800 A Non-Insulated Bus
$1,500
$1,750
800 A Insulated Bus
$2,150
$2,195
1N
1,200 A Non-Insulated Bus
$1,750
$1,850
1I
1,200 A Insulated Bus
$2,500
$2,555
2N
2,000 A Non-Insulated Bus
$2,750
$2,795
2I
2,000 A Insulated Bus
$3,795
$3,850
NR
None Required
$0
$0
Bus not required for single stand-alone unit.
+
Bus is required for connection of 2 or more units.
Any unit with bus greater than 36” will require additional MLO section. Please contact the factory for pricing and delivery.
3-32
benshaw.com
Return to the
Table of Contents
Power Factor Correction Capacitors
Power factor correction capacitors (PFCCs) are available
in two options.
1. If the starter requires a UL label, the power factor capacitors are installed on the top of
the unit (capacitors are shipped loose and must be installed by customer) or in a separate
enclosure to be installed next to the starter. The top mount will add approximately 28
inches to the enclosure height. Top mount is only available up through 225 kVAR, 4.8 kV.
The separate enclosure (dimensions: 92"Hx30"Wx36"D) can house up to 2 PFCC units.
For remote mount, contact factory.
2. For units not requiring UL approval, capacitors may be installed inside the enclosure.
Both options require enclosure width to increase to the next standard size to accommodate
the added contactor. Capacitors are three phase, supplied with three fuses, rated for
60 Hz operation.
PFCCs are available for voltages up through 13.8 kV.
Available Sizes:
• 25 kVAR increments for 2.3 kV through 4.8 kV, starting at 25 kVAR
• 50 kVAR increments for 6 kV through 13.8 kV, starting at 50 kVAR
Consult factory for dimensions.
Information Required for Sizing
(Note: Industry standard is to correct to a 0.95 PF.)
1. Motor HP:______________________________
2.Voltage:________________________________
3. Existing Power Factor:___________________
4. Corrected Power Factor:_________________
Return to the
Table of Contents
3-33
Engineered Medium
Voltage Starter Options
Surge / Lightning Arrestors
The surge or lightning arrestors are available in two options. If the unit is required to be UL approved, the surge arrestors must be installed on the
top of the unit (components are shipped loose and must be installed by customer). This will add eighteen inches to the height of the enclosure.
For units not requiring UL approval, the arrestors may be installed inside the enclosure. This requires the enclosure width to increase to the next
standard size. Includes the hardware necessary to mount and wire the arrestors and the increased size of the enclosure where required.
Non-UL Labeled Starter Inside Mount
Option Code
Description
List Price
A901
Surge Arrestor, 2300 VAC
$2,000.00
A902
Surge Arrestor, 3300 VAC
$2,000.00
A903
Surge Arrestor, 4160 VAC
$2,000.00
A904
Surge Arrestor, 4800 VAC
$2,000.00
A905
Surge Arrestor, 6900 VAC
$2,500.00
A906
Surge Arrestor, 9000 VAC
$2,500.00
A907
Surge Arrestor, 12000 VAC
$3,000.00
UL Labeled Starter Top Mount - 18" Height Adder (18"H x 30"W x 24"D top hat shipped loose)
Option Code
Description
List Price
A925
Surge Arrestor, 2300 VAC
$2,250.00
A926
Surge Arrestor, 3300 VAC
$2,250.00
A927
Surge Arrestor, 4160 VAC
$2,375.00
A928
Surge Arrestor, 4800 VAC
$2,375.00
A929
Surge Arrestor, 6900 VAC
$2,500.00
A930
Surge Arrestor, 9000 VAC
$2,500.00
A931
Surge Arrestor, 12000 VAC
$3,000.00
3-34
benshaw.com
Return to the
Table of Contents
Surge Capacitors
Surge capacitors will be supplied in a top hat package for starters that must maintain the UL label. This will add to the height of the enclosure
(components are shipped loose and must be installed by customer). For non-UL units, the capacitors are packaged into the unit, which increases
the width of the enclosure up to the next standard size. Non-UL Labeled Starter Inside Mount
Option Code
Description
A950
Surge Capacitor, 2300 VAC
List Price

A951
Surge Capacitor, 3300 VAC

A952
Surge Capacitor, 4160 VAC

A953
Surge Capacitor, 4800 VAC

A954
Surge Capacitor, 6900 VAC

A955
Surge Capacitor, 9000 VAC

A956
Surge Capacitor, 15 kV

Consult factory
UL Labeled Starter Top Mount - 18” Height Adder (18”H x 30”W x 24”D top hat shipped loose)
Option Code
Description
A975
Surge Capacitor, 2300 VAC
List Price

A976
Surge Capacitor, 3300 VAC

A977
Surge Capacitor, 4160 VAC

A978
Surge Capacitor, 4800 VAC

A979
Surge Capacitor, 6900 VAC

A980
Surge Capacitor, 9000 VAC

A981
Surge Capacitor, 15 kV

Consult factory
Return to the
Table of Contents
3-35
Engineered Medium
Voltage Starter Options
Line Reactors
For 2.4 kV solid state starters, line reactors are not required.
For 5 kV / 7.2 kV solid state starters, line reactors are required when the supply source transformer is greater than 20 MVA (5% Impedance) or the
motor lead wiring length is 1,000 feet or greater. For systems with custom motor control lineups and power factor correction capacitors, consult
the factory.
For 13.8 kV starters, consult factory for the requirement of line reactors.
The line reactors are available in two options. If the unit is required to be UL approved, the reactors must be installed on the top of the unit
(reactors are shipped loose and must be installed by customer). This will add to the height of the enclosure. For units not requiring UL approval,
the reactors may be installed inside the enclosure. The inside mounting requires the enclosure width to increase to accommodate the added
reactor. The price includes the hardware necessary to mount and wire the reactors and the increased size of the enclosure where required.
A de-tuning reactor may be required to protect the power system from the adverse interaction of capacitors and non-linear loads. To ensure
the power factor correction device is properly applied, consult a qualified engineer or provide your single line electrical diagrams to Benshaw
for evaluation.
4,160 V Starter Inside Mount
Option Code
HP
List Price
A985
750

A986
1500

A987
3000

A988
>3000

Consult factory
4,160 V UL Labeled Starter Top Mount
Dimensions (in.)
Option Code
HP
H
W
D
List Price
A991
750
22
22
24

A992
1500
23
24
24

A993
3000
23
24
24

A994
>3000




Consult factory on other voltage ratings in the 5 and 7.2 kV class.
Consult factory
3-36
benshaw.com
Return to the
Table of Contents
Documentation
Benshaw offers a variety of documentation options to fit your project scope, budget and timeline. Only Benshaw offers the flexibility in our
approval process to help meet our customers’ project schedules. All of our documentation packages are processed through our highly technical
engineering department. Please contact Benshaw for pricing and delivery. Please ensure all documentation requirements are on the purchase
order. Electronic copies are provided unless hard copies are specified on the purchase order.
Preliminary Drawings
Full Submittals
Preliminary drawings consist of the “released to manufacturing”
drawings that are used in production. This drawing package does not
include any form of customer approvals. The drawing package includes
the internal and external layout, and schematics.
Full submittal packages ensure that no equipment will be purchased
for the project until the customer’s approval for production is received.
The full submittal package includes the internal and external layout,
schematics and cut sheets for major components.
Partial Approvals
As-Built Drawings
Partial approval drawings allow Benshaw to purchase long-lead items
that will not change prior to the customer’s approvals. This allows
Benshaw to cut down on the delivery time while still allowing the
customer all the flexibility and control in an approval process. The
partial approval package includes the internal and external layout,
and schematics.
As-built drawings are typically sent out two weeks after shipment and
incorporate all the changes that occur during the production process,
testing and FAT test (if applicable).
Full Approvals
Full approval drawings ensure that no equipment will be purchased
for the project until the customer’s approval for production is received.
The full approval package includes the internal and external layout,
and schematics.
Partial Submittals
Partial submittal packages allow Benshaw to purchase long-lead
items that will not change prior to the customer’s approvals. This
allows Benshaw to cut down on the delivery time while still allowing
the customer all the flexibility and control in an approval process.
The partial submittal package includes the internal and external
layout, schematics and cut sheets for major components.
Return to the
Table of Contents
O&M Manuals
O&M manuals are typically sent out four weeks after delivery.
O&M manuals also include as-built drawings.
Witness Testing (FAT Testing)
Witness testing includes a testing plan and procedure that must
be reviewed and approved in advance by the customer. Quotations
are for standard Benshaw testing, and any special testing needs or
requirements must to be brought up to Benshaw to ensure accurate
scheduling. Witness testing can occur starting the week after the
equipment is ready to ship, adding to the delivery time frame,
and must be scheduled beforehand.
3-37
Engineered Medium
Voltage Starter Options
Wound Rotor Starters
RATINGS
Horsepower:
1,000–10,000 HP*
Overload:
500% for 30 seconds
125% continuous
Starting Torque:
0–100%
Voltage:
2.4, 3.3, 4.1 and 6.6 kV**
Typical Resistance Steps:
1–2
* Consult factory for higher HP rating.
** Consult factory for higher voltage rating.
Product Highlights:
Wound rotor motors are typically used in applications requiring high starting torques, a limited
number of operating speeds or a stepped acceleration to achieve a soft start. Typical existing
applications utilize an electromechanical starter on the stator and introduce multiple stages of
resistance in the rotor via contactor arrangements to achieve a soft ramp.
With the RediStart MX3, wound rotor control is greatly simplified. The RediStart consists of
two major sections: 1) A solid-state stator control, and 2) secondary resistors into the rotor
circuit from a separate 3-phase resistor bank. This achieves the high torque required by the
application—with low inrush—while providing a smooth stepless start. This greatly reduces
the maintenance cost of the typical electromechanical control.
Single Step Rotor Control: The solid-state starter is wired to the motor stator circuit, and
the resistor and shorting contactor are wired to the motor rotor circuit. The solid state starter
accelerates the motor to slip speed (determined by the resistance value) and then activates
the contactor to short the rotor. This allows the motor to accelerate to full speed.
Multiple Step Rotor Circuit: WR RVSS series starters can be supplied with multiple stages of
rotor resistor and contactor combinations. This arrangement may be necessary for multiple step
starting of extremely high inertia loads, or for continuous operation at multiple speeds. Multiple
steps of rotor resistance can be coordinated to achieve this.
Variable Speed Control: Variable speed control of wound rotor motors can be accomplished
with the RediStart series control. By maintaining full output voltage of the control going to
the stator of the wound rotor motor, and varying the resistance in the rotor, variable speed
is accomplished.
Resistors must be rated for continuous duty operations. Variable loads (pumps and fans) only.
Key Advantages:
• Benshaw MX3 technology
• Modbus capable
• Single step rotor control
• Configurable output relays
• Modular power stack design for ease
• Multistep & variable speed
of maintenance
• Reduced maintenance
• Advanced MX3 motor protection
• Reduced in size and number
• Advanced MX metering function
3
• Real time clock
• 99 event log history
3-38
benshaw.com
rotor control available
• Integral bypass contactor design
of resistors needed
• Stepless control
• Reduces inrush while maintaining torque
Return to the
Table of Contents
Wound Rotor Motor Starter Check List
Present starting
 Across the line
method
 Other ___________________________________
Rotor circuit
information
Present number of steps of
resistance ____________
Total starting ohm value
____________ ohms
Current
method of
resistance
shorting
Step one ____________ sec.
Step two _________ sec.
Step three______ sec.
Step four _____ sec.
Step five ____ sec.
The present number of steps may be more or less than listed above. Please specify.
Motor
information
Primary
voltage______________
Secondary
voltage_______________
Primary
amps________________
Secondary
amps_________________
RPM ________________
Service
Factor________________
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Return to the
Table of Contents
3-39
Engineered Medium
Voltage Starter Options
Synchronous Starters
SEP Series
RATINGS
Horsepower:
1,000–10,000 HP*
Overload:
500% for 30 seconds
125% continuous
Starting Torque:
0–100%
Product Highlights:
The sync motor functions as an induction motor during start up. Once the motor
approaches full synchronous speed, the Redistart DC exciter induces a constant
polarity to the rotor causing the motor to lock into sync. Because the rotor’s field
is constant and separately excited there is no slip required to produce torque,
as with an induction motor. This allows the motor to run at synchronous speed.
The Benshaw synchronous package consists of a solid state starter portion connected
to the stator and an SEP (synchronous excitation package) that is connected to the
rotor section in conjunction with a discharge resistor. This SEP is supplied for brush
type and brushless exciters.
Synchronous Benefits:
The RediStart series solid state starter provides reduced voltage stepless acceleration
and automatic synchronization of three phase AC synchronous motors. Synchronous
motors are utilized for a number of reasons. They are used in applications that require
precise motor speed, they are used to obtain greater efficiencies, and they are used
for facility power factor correction.
2.4, 3.3, 4.1 and 6.6 kV**
Since synchronous motors can be operated at leading power factor, they are used
to correct a facility’s lagging power factor created by all the other induction motors
being operated.
Exciter Ratings:
This correction reduces the penalty a customer pays the utility company for creating
poor power factor.
125–250 VDC
30–120 A***
Key Advantages:
Voltage:
• Benshaw synchronous technology
• Modbus communication
* Consult factory for higher HP rating.
• Solid state synchronous rotor control
• Configurable output relays
** Consult factory for higher voltage rating.
• Modular power stack design
• Reduced maintenance
*** Consult factory for higher amp rating.
for ease of maintenance
• Reduction in size compared
• Integral bypass contactor design
to existing field control
• Advanced synchronous
• Stepless control
motor protection
• Can be added to existing equipment
• Can be supplied with MX or MX
2
3
• Reduces inrush while
maintaining torque
• Brush type and brushless control
starter control
3-40
benshaw.com
Return to the
Table of Contents
Synchronous Motor Starter Check List
Present starting
 Across the line
method
 Other ______________________
Application _______________________
Field discharge resistor value____________ohms
Motor
information
Motor horsepower__________
Motor frequency ________Hz
Field voltage_______________
Max field current __________
Full load current____________
Motor LRA________________
RPM______________________
Service Factor_____________
Motor Wk2 ________________
Load Wk2_________________
Motor voltage________
Motor Speed ____RPM
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Options :
 Brushless exciter
 Brush Type exciter
 Circuit Breaker
 Fusible Switch
 No disconnect needed
 Bypass contactor run duty only
 120 VAC control power by Benshaw
 Start Stop Pushbutton
 Hand Off Auto
Return to the
Table of Contents
 Local Off Remote
 2-Wire Control
 3-Wire Control
3-41
MX3 intelligent motor control centers,
Benshaw can custom configure intelligent, MX3 based motor starters, complete
control centers and lineups to meet the needs of any load, in any industry.
Incoming Sections:
• Main breakers or disconnects
• Main-Tie-Main arrangements
• Main lug only sections
• 1200 / 2000 / 3000 amp circuit breakers
• 400 / 600 / 1200 amp load break fault
make disconnects
• Surge protection devices
• Metering and communications
3-42
benshaw.com
Custom Configured Multiple
Unit MCC Lineups:
• Transition sections to
third party equipment
• 800 / 1200 / 2000 / 3000 amp
horizontal bus
• Reduced voltage / full voltage /
Intelligent MCC Integration:
• Easy MCC networking
• MTMS, disconnects, feeders,
SSRV, ATL, PAM, 2 speed starters
• Diagnostics and communications
• Intelligent SSRVS power poles
feeder controls
• Back to back construction
Return to the
Table of Contents
lineups, and main-tie-main arrangements
Fused Disconnect
MTM 7.2 kV motor
control center with
integrated power
factor correction
Draw Out Circuit Breaker MTM with (6) 5 kV solid state starters
Integrated Supervisory Control and Predictive
Maintenance Systems:
In applications requiring the coordination and control of
multiple RediStart™ starters and third party equipment,
Benshaw has the experience and technology to design
and deliver integrated control systems:
• PC-based systems
• Local area networks
• Local / remote communications and control
• Data collection and monitoring
Fixed Mount Circuit
Breaker MTM
(only 48" deep)
48" space savings
vs. typical 96"
competitive unit
Packaged Electrical and Control Systems
Benshaw can also design and manufacture completely
packaged portable or stationary electrical systems for
applications requiring self-contained modules, including:
• 20- or 40-foot containers
• Self-contained air conditioning and lighting
• Low and medium voltage equipment
• Remote monitoring and control
• Personnel and support facilities
• PLC design, programming and integration
• Online and offline predictive maintenance
Return to the
Table of Contents
3-43
Mission critical reliability
in any configuration
Industry Experience:
• Aggregate and mining
• Cement production
• Chemical processing
• Municipal fresh and
waste water treatment
• Oil and gas production
• Power generation
• Pulp and paper production
• Steel and aluminum
Low profile skid mounted
Application Experience:
• Ball / hammer / rolling mills
• Centrifuges
• Chillers
• Compressors
• Conveyors
• Crushers / hydra pulpers
• Fans and blowers
• Mixers and refiners
• Pumps
Motor control
center with power
factor correction
Protective relays
and PLC logic
20 MW, 13.8 kV
When it absolutely has to work,
it absolutely has to be Benshaw.
3-44
benshaw.com
Fixed-mount circuit
breaker MTM
Upright skid mounted
Return to the
Table of Contents
Low Voltage Starters
Standard Low Voltage Starter Products
Intelligent Motor Control....................4-2
Open Chassis Solid State Starters....... 4-7
Prepackaged Starters
with ATL Bypass................................4-16
Prepackaged Starters........................4-18
Engineered Low Voltage Starter Products
Wound Rotor Starters.......................4-24
Wound Rotor Motor Starter
Check List..........................................4-25
Synchronous Starters.........................4-26
Synchronous Motor Starter
Check List.......................................... 4-27
Solid State Starters
with Reversing Control......................4-28
Solid State Starters
with Two Speed Control....................4-29
Solid State Starters
Part Number Assembler....................4-30
Return to the
Table of Contents
4-1
4-1
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 3 Controller
Fiber Optic Firing
• Integrated technology
• Noise immunity
• High voltage isolation
• Safe, reliable SCR control
Product Highlights:
Next generation MX3 technology forms the backbone of Benshaw’s entire line
of intelligent medium voltage motor controls. With fiber optic firing, enhanced
programming capabilities, ease of use and a unique, flexible architecture, Benshaw’s
MX3 controller delivers unprecedented functionality and all of the rugged, dependable
performance you’ve come to expect from the world leader in solid state motor
controls and drives.
MX3 controllers, power components, software and sensors are all designed, built
and tested to perform as an integrated control system, eliminating the coordination
and performance problems inherent in other forms of reduced voltage starting.
With more built-in features, more configurable options, greater expandability and
a broader communications capability than any other motor control on the market,
Benshaw’s next generation MX3 technology will shorten your commissioning times,
improve motor performance and protection, enhance diagnostic capability and
streamline many electrical system monitoring and maintenance tasks.
Keypad (Included)
Key Features:
• High performance motor control with multiple starting modes built-in
• Patented CYCLO Converter control from 1 to 40% speed
• Flexible, programmable I/O
• Integrated motor protection
• Line and motor metering
• Diagnostic capabilities with event log and real-time clock
• UL, CUL, NEC, NEMA compliance
• Built-in remote self-testing (BIST)
• Expanded communications capabilities
Optional RTD Modules
• Intelligent SCR power poles
• Intelligent MV MCC integration
4-2
benshaw.com
Return to the
Table of Contents
Intelligent Motor Control
Control Features
Multiple Starting Modes:
• Voltage ramp
• Current ramp
–– Adjustable initial current
–– Adjustable maximum
current
–– Adjustable ramp time
• Torque ramp (TruTorque™)
Metering:
8 Digital Inputs
Configurable to:
• Accuracy:
1 Analog 4 – 20 mA /
0 – 10 VDC Input
Configurable to:
–– 3% out-of-box
• Stop
–– 2% factory calibrated
• Fault
• Trip high level
• Average current
• Fault reset
• Trip low level
• L1 current
• Bypass / inline confirm
• L2 current
• OL reset
1 Analog 4 – 20 mA /
0 – 10 VDC Output
Configurable to:
• L3 current
• Local / remote selection
–– Adjustable initial torque
• Current imbalance %
• Heater enable
• Current (0 – 200%/0 – 800%)
–– Adjustable maximum
torque
• Ground fault current
• Heater disable
• Voltage (0 – 150%)
• Average volts
• Dual ramp selection
• OL (0 – 150%)
• L1 – L2 voltage
• 1 dedicated start input
• kW (0 – 10 kW/0 – 100 kW)
• L2 – L3 voltage
• Disconnect
• MW (0 – 1 Mw)
• L3 – L1 voltage
• Slow speed
• Analog input (0 – 100%)
• Overload %
• Brake enable
• Firing (0 – 100%)
• Power factor
• Brake disable
• Calibration
6 Relay Outputs
Configurable to:
User Interface:
–– Adjustable ramp time
• Power ramp
–– Adjustable initial torque
–– Adjustable maximum
torque
–– Adjustable ramp time
• Linear / tach feedback control
• Watts
• CYCLO converter control
• VA
• Event log (99 events)
• VARS
• Faulted
• KW hours
• Running
• MW hours
• Up to speed
• Phase order
• Alarm condition
• Up to speed timer exceeded
• Line frequency
• Ready condition
• Low line voltage
• Analog input
• Locked out
• Low line frequency
• Analog output
• Over current
• High line frequency
• Run time — days
• Under current
• Phase reversal
• Run time — hours
• OL alarm
• Phase loss
• # of starts
• Shunt trip
• Instantaneous overcurrent
• TruTorque %
• Ground fault
• Dual ramp selection
• Overcurrent
• Power %
• Energy saver indication
• Adjustable kick current
• Undercurrent
• Peak starting current
• Heating indication
• Programmable decel modes
• Current imbalance
• Last starting duration
• Slow speed forward / reverse
• MV BIST test (built-in self test)
• Ground fault (residual
• RTD temperatures
• DC braking
• Real-time clock
• Cooling fan
Motor Protection:
• Motor thermal overload
• Independent starting
and running OLs
or zero sequence)
• Shorted or open SCR
™
• Door mounted LCD display
–– Set / examine operating
parameters
–– View status information,
line current, voltage
and frequency
–– Start and stop the solid
state starter
1 Communication Port:
• ModBus / RS485
Advanced Functionality:
• Disconnect fault
• Inline contactor fault
• Control power low
• Stack over temperature
• Motor PTC input
• RTD modules
Return to the
Table of Contents
4-3
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 2 Controller
Product Highlights:
The new MX2 control technology from Benshaw provides a powerful, flexible,
intelligent low voltage motor control platform. MX2-based controls offer multiple,
user selectable starting modes, an increased selection of configurable digital and
analog I/Os, comprehensive built-in metering capabilities, unprecedented onboard
protection and an easy to use, intuitive user interface.
The new control board terminal configuration—coupled with programmable
burden CT settings—makes Benshaw’s MX2 technology an excellent choice
for a wide range of intelligent, soft start motor control applications.
With more built-in starting modes, more built-in protection features, additional
communications capabilities, improved noise immunity, a more complete user I/O
and CE compliance, Benshaw’s new MX2-based low voltage motor controls raise
the bar for intelligent, low-cost, soft start motor control.
When you factor in our 24/7 comprehensive technical support, we think you’ll find
Benshaw’s MX2-based controls to be an excellent value.
Keypad
Standard Features:
• High performance motor control
with multiple starting modes built in
• Jogging 7% and 14% speed
• 3 user configurable digital inputs
• 2 fixed inputs for start
and bypass confirm
• 3 user configurable output relays
and 1 fixed bypass confirm
• Power stack thermistor
• Data snapshot of each fault
• Power up on start
• 1000V capable
• Energy saver
• Remote keypad ready
• CE, UL, CUL, NEMA compliance
• User configurable analog I/O
• Built-in self-testing (BIST)
• Programmable burden CT settings
• ModBus 485 plus expanded
• Residual ground fault
• Advanced line / motor metering
communications capabilities
with optional bridges
• DC braking light duty
MX2 Board
4-4
benshaw.com
Return to the
Table of Contents
Intelligent Motor Control
Control Features
Multiple Starting Modes:
Metering:
3 Digital Inputs
Configurable to:
1 Analog 4 – 20 mA /
0 – 10 VDC Input
Configurable to:
• Voltage ramp
• +/- 2% accuracy
• Current ramp
• Average current
• Stop
–– Adjustable initial current
• L1 current
• Fault
• Trip high level
–– Adjustable maximum
current
• L2 current
• Fault reset
• Trip low level
• L3 current
• Bypass / confirmation
–– Adjustable ramp time
• Torque ramp (TrueTorque™)
–– Adjustable initial torque
–– Adjustable maximum
torque
–– Adjustable ramp time
• Power ramp
–– Adjustable initial torque
–– Adjustable maximum
torque
–– Adjustable ramp time
• Linear / tach
feedback control
• Jogging 7% and 14% speed
Motor Protection:
• Current imbalance %
• Ground fault amps/residual
• Average volts
• L1 – L2 voltage
• L2 – L3 voltage
• L3 – L1 voltage
• Overload %
• Power factor
• Watts
• VA
• MW hours
• Phase order
• Independent starting
• Analog input
• Low line voltage
• Low line frequency
• High line frequency
• Phase reversal
• Phase loss
• Instantaneous overcurrent
• Overcurrent
• Undercurrent
• Current imbalance
• Ground fault residual
• Shorted SCR
• Disconnect fault
• Analog output
• Run time — days
• Run time — hours
• # of starts
• TruTorque %
™
• Power %
1 Analog 4 – 20 mA /
0 – 10 VDC Output
Configurable to:
• Local / remote selection
• Current (0 – 200%/0 – 800%)
• Heater enable
• Voltage (0 – 150%)
• Heater disable
• OL (0 – 150%)
• Dual ramp selection
• kW (0 – 10 kW/0 – 100 kW)
• 1 dedicated start input
• MW (0 – 1 MW)
• 1 dedicated bypass
• Analog input (0 – 100%)
3 Relay Outputs
Configurable to:
• Faulted fail safe
• KW hours
• Line frequency
• Up to speed timer exceeded
• OL reset
• Starter off
• VARS
• Motor thermal overload
and running OLs
& inline
and non fail safe
• Running
• Up to speed
• Alarm condition
• Ready condition
• Firing (0 – 100%)
• Calibration
User Interface:
• Standard board-mounted
LED interface
• Optional remote mount
LCD display
–– Set / examine operating
parameters
• Locked out
–– View status information
• Over current trip
–– View line current, voltage
and frequency in real time
• Under current trip
• OL alarm
• Shunt trip fail safe
and non fail safe
• Peak starting current
• Ground fault
• Last starting duration
• Energy saver indication
–– Start and stop the solid
state starter
1 Communication Port:
• ModBus / RS485
Advanced Functionality:
• Heating indication
• Dual ramp selection
• Slow speed forward / reverse
• Adjustable kick current
• DC braking
• Programmable decel modes
• Cooling fan
• LV BIST test (built-in self test)
• 1 fixed bypass
• Inline contactor fault
• Control power low
• Stack over temperature
Return to the
Table of Contents
4-5
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 3 / MX 2 Controllers
Control Feature Comparison
MX2 MX3
Miscellaneous
Voltage Ramp
Protection (continued)


Current Ramp


TruTorque™ Ramp


Power Ramp


Tach / Speed Control Ramp
Linear Ramp Profiles


Squared and S Ramp Profiles
Dual Ramps




Kicking


Voltage Decel


TruTorque™ Decel


DC Braking


Heater / Antiwindmill


Jogging 7–14% Speed


Slow Speed Cyclo™ Operation
0–40% speed


Inside Delta


Wye-Delta/
Electromechanical Control


Phase Controller


Current Follower


ATL


Protection
Separate Starting / Running


Adj. Hot / Cold Ratio


Adj. Cooling Time


Intelligent Start Lockout

Adj. OL Lockout Level

Over / Under Current Protection


Retained OL When Power Lost


Current Imbalance Protection


IOC (Instantaneous
Over Current)


Open / Shorted SCR Detection


Overcurrent / Shear Pin


Undercurrent / Load Loss


Residual Ground
Fault Protection


benshaw.com
MX2 MX3
Metering
Zero Seq. Ground
Fault Protection

Full Voltage and
Current Metering


Starts Per Hour

True RMS Calculation


RTD Monitoring

Factory Menu Calibration


Motor PTC

Current Imbalance Meter


Stack OT Switch


Ground Fault Meter


Stack Thermistor Input


Watt Meters


Backspin Timer

KVA Meters


Time Between Starts

VAR Meter


Phase Rotation


Watt Hour Meters


Overvoltage


Line Frequency Meter


Undervoltage


Power Factor Meter


Phase Loss


% OL Meter


UTS / Stall Timer


Time Until OL Lockout
Release Meter


Phase Rotation Meter


& Power and %
TruTorque™ Meter


Run Time Meter


Number of Starts Meter


Peak Current of Last Start Meter


Last Starting Time Meter




Zero Speed Switch

PF Trip

PORT (Power Outage
Ride Through)

Keypad Fault Reset


Adj. Auto Fault Reset Timer


Adj. No. of Auto Resets
Before Lockout


Decel After Fault


Analog Input Meter
Fault Log


Real Time Clock


RTD Meters


Miscellaneous

LV BIST


MV BIST


LV Powered BIST


Time and Date Stamp
Overload Classes
4-6
MX2 MX3
9 Data Snapshots of Each Fault

Event Log (last 99 events)
Fault Classes
User I/O
Programmable Digital Inputs


Programmable Digital Outputs


User Analog Input


Programmable User
Analog Output


Local / Remote Source Input


Power Up Start


Return to the
Table of Contents
Open Chassis Solid State Starters
RB Series MX 3 or
MX 2 Technology
With Integral Bypass
Product Highlights:
Benshaw’s RB series solid state starter combines the high performance MX2 or MX3
technology with a rugged, compact, integral bypass RB series power section.
The MX2 or MX3 technology provides users with a powerful group of programming
parameters, designed for flexibility in across a wide range of industrial applications.
Both MX2 and MX3 controls provide simple setup and commissioning via the Quick
Start Menu.
The RB power section is a rugged, heavy duty solid state starter section designed
with integral bypass contactors for a compact, efficient profile. The modular design
includes separate poles for each phase for ease of maintenance.
Key Advantages:
• Small, compact design
• Modular power stack assembly
for ease of maintenance
• ModBus standard /
other Fieldbus optional
• Multiple starting ramps
for various applications
• Integrated metering
• Integral bypass contactors for
efficient operation, eliminating
the need for external fans
• Integrated motor protection
• Dual ramp capability for loaded /
unloaded applications
• Power stack has multiple ratings
for application flexibility
system diagnostics
NEMA 2-Hole Pattern
(Bottom Entry / Bottom Exit)
SCRs in Reverse
Parallel Configuration
DV / DT Protection
Stack Over-Temperature
Protection
NEMA 2-Hole Pattern
(Top Entry / Top Exit)
Integral Bypass
Contactor
RB Power Pole — 180A
Return to the
Table of Contents
4-7
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB Series MX 3 or MX 2 Technology
Product Selection Guide
Horsepower
Model Number
208 V
240 V
480 V
575 V
Standard Duty — 350% for 30 Sec. 115% Continuous
RB2-1-S-027A-11C
7.5
10
20
25
RB2-1-S-040A-11C
10
15
30
40
RB2-1-S-052A-12C
15
20
40
50
RB2-1-S-065A-12C
20
25
50
60
RB2-1-S-077A-13C
25
30
60
75
RB2-1-S-096A-13C
30
40
75
100
RB2-1-S-125A-14C
40
50
100
125
RB2-1-S-156A-14C
50
60
125
150
RB2-1-S-180A-14C
60
75
150
200
RB2-1-S-240A-15C
75
100
200
250
RB2-1-S-302A-15C
100
125
250
300
RB2-1-S-361A-16C
125
150
300
400
RB2-1-S-414A-17C
150
-
350
500
RB2-1-S-477A-17C
-
200
400
RB2-1-S-515A-17C
200
-
450
-
RB2-1-S-590A-18C
-
250
500
600
RB2-1-S-720A-19C
250
300
600
700
RB2-1-S-838A-20C
300
350
700
800
Heavy Duty — 500% for 30 Sec. 125% Continuous
RB2-1-S-027A-11C
7.5
10
20
25
RB2-1-S-040A-11C
10
15
30
40
RB2-1-S-052A-12C
15
20
40
50
RB2-1-S-096A-13C
30
40
75
100
RB2-1-S-156A-14C
40
50
100
125
RB2-1-S-180A-15C
60
75
150
200
RB2-1-S-361A-16C
75
100
200
250
RB2-1-S-414A-17C
125
150
300
400
RB2-1-S-590A-18C
200
200
450
500
RB2-1-S-720A-19C
-
250
500
600
Severe Duty — 600% for 30 Sec. 125% Continuous
RB2-1-S-027A-11C
5
7.5
15
20
RB2-1-S-040A-11C
10
10
30
40
RB2-1-S-052A-11C
-
15
-
-
RB2-1-S-096A-13C
25
30
60
75
RB2-1-S-180A-14C
30
40
75
100
RB2-1-S-180A-15C
50
60
125
150
RB2-1-S-361A-16C
60
75
150
200
RB2-1-S-414A-17C
100
125
250
300
RB2-1-S-590A-18C
150
200
450
500
4-8
benshaw.com
Return to the
Table of Contents
Open Chassis Solid State Starters
RB2 Series with MX 2 Technology
Standard Duty / 200–600 Volt
350% for 30 Sec. / 115% Continuous Rated
Horsepower
Dimensions (in.)
Model Number
A
208 V
240 V
480 V
575 V
H
W
D
Weight
(lbs.)
List Price
 RB2-1-S-027A-11C
27
7.5
10
20
25
14
10
6.9
14
$1,745.00
 RB2-1-S-040A-11C
40
10
15
30
40
14
10
6.9
14
$1,825.00
 RB2-1-S-052A-12C
52
15
20
40
50
14
10
8.4
17
$1,900.00
 RB2-1-S-065A-12C
65
20
25
50
60
14
10
8.4
17
$1,935.00
 RB2-1-S-077A-13C
77
25
30
60
75
15
10
8.4
17
$2,045.00
 RB2-1-S-096A-13C
96
30
40
75
100
15
10
8.4
18
$2,665.00
 RB2-1-S-125A-14C
125
40
50
100
125
21.7
12.3
8.9
43
$2,935.00
 RB2-1-S-156A-14C
156
50
60
125
150
21.4
14
9
43
$3,500.00
 RB2-1-S-180A-14C
180
60
75
150
200
21.4
14
9
43
$4,265.00
 RB2-1-S-240A-15C
240
75
100
200
250
23.8
12.5
10.3
51
$4,550.00
 RB2-1-S-302A-15C
302
100
125
250
300
23.8
12.5
10.3
51
$5,000.00
 RB2-1-S-361A-16C
361
125
150
300
400
23.9
13.3
9.2
56
$5,855.00
 RB2-1-S-414A-17C
414
150
-
350
-
27.9
18
11.1
151
$6,385.00
 RB2-1-S-477A-17C
477
-
200
400
500
28.9
18
11.1
155
$7,000.00
 RB2-1-S-515A-17C
515
200
-
450
-
28.9
18
11.1
155
$7,500.00
 RB2-1-S-590A-18C
590
-
250
500
600
28.8
18
11.1
159
$8,000.00
 RB2-1-S-720A-19C
720
250
300
600
700
30.7
18.5
10.9
159
$9,000.00
 RB2-1-S-838A-20C
838
300
350
700
800
29.1
26.1
12.5
160
$10,500.00

Web stocked
Available for same day shipping.
Unit requires separate 120 V control power.
Unit includes standard board-mounted LED interface.
The optional LCD interface is shown.
The keypad is shipped loose.
Model Number
Description
KPMX3CBL2M
NEMA 12 / 3R Remote
Keypad with 2 Meter Cable
Return to the
Table of Contents
List Price
$425.00
4-9
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB3 Series with MX 3 Technology
Standard Duty / 200–600 Volt
350% for 30 Sec. / 115% Continuous Rated
Horsepower
Model Number
240 V
480 V
Dimensions (in.)
575 V
H
W
D
Weight
(lbs.)
A
208 V
List Price
 RB3-1-S-027A-11C
27
7.5
10
20
25
14
10
7.7
14
$2,595.00
 RB3-1-S-040A-11C
40
10
15
30
40
14
10
8.4
14
$2,625.00
 RB3-1-S-052A-12C
52
15
20
40
50
14
10
9.2
17
$2,735.00
 RB3-1-S-065A-12C
65
20
25
50
60
15
10
9.2
17
$2,750.00
 RB3-1-S-077A-13C
77
25
30
60
75
15
10
9.2
17
$3,055.00
 RB3-1-S-096A-13C
96
30
40
75
100
15
10
9.2
18
$3,575.00
 RB3-1-S-125A-14C
125
40
50
100
125
21.5
12.3
9.7
43
$3,825.00
 RB3-1-S-156A-14C
156
50
60
125
150
21.7
14
9.8
43
$4,345.00
 RB3-1-S-180A-14C
180
60
75
150
200
21.7
14
9.8
43
$5,000.00
 RB3-1-S-240A-15C
240
75
100
200
250
23.8
12.5
11.1
51
$5,250.00
 RB3-1-S-302A-15C
302
100
125
250
300
23.8
12.5
11.1
51
$5,725.00
 RB3-1-S-361A-16C
361
125
150
300
400
23.9
13.4
10
56
$6,455.00
 RB3-1-S-414A-17C
414
150
-
350
-
27.9
18
11.9
151
$6,950.00
 RB3-1-S-477A-17C
477
-
200
400
500
28.9
18
11.9
155
$7,500.00
 RB3-1-S-515A-17C
515
200
-
450
-
28.9
18
11.9
155
$8,000.00
 RB3-1-S-590A-18C
590
-
250
500
600
28.9
18
11.9
159
$8,700.00
 RB3-1-S-720A-19C
720
250
300
600
700
30.7
18
11.7
159
$9,500.00
 RB3-1-S-838A-20C
838
300
350
700
800
29.1
26.1
13.3
160
$11,000.00
 Built-to-order: Please allow 2 weeks for shipment.
Unit requires separate 120 V control power.
Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.
4-10
benshaw.com
Return to the
Table of Contents
Open Chassis Solid State Starters
RB2 Series with MX 2 Technology
Heavy Duty / 200–600 Volt
500% for 30 Sec. / 125% Continuous Rated
Horsepower
Model Number
A
208 V
240 V
480 V
575 V
Weight
(lbs.)
List Price
 RB2-1-S-027A-11C
24
7.5
10
20
25
14
$1,745.00
 RB2-1-S-040A-11C
40
10
15
30
40
14
$1,825.00
 RB2-1-S-052A-12C
52
15
20
40
50
17
$1,900.00
 RB2-1-S-096A-13C
96
30
40
75
100
18
$2,665.00
 RB2-1-S-156A-14C
125
40
50
100
125
43
$4,635.00
 RB2-1-S-180A-15C
204
60
75
150
200
43
$5,975.00
 RB2-1-S-361A-16C
252
75
100
200
250
56
$6,500.00
 RB2-1-S-414A-17C
372
125
150
300
400
151
$8,525.00
 RB2-1-S-590A-18C
551
200
200
450
500
159
$9,795.00
 RB2-1-S-720A-19C
623
-
250
500
600
160
$9,795.00
 Web stocked
Available for same day shipping.
Unit requires separate 120 V control power.
Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.
Return to the
Table of Contents
4-11
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB3 Series with MX 3 Technology
Heavy Duty / 200–600 Volt
500% for 30 Sec. / 125% Continuous Rated
Horsepower
Dimensions (in.)
Model Number
A
208 V
240 V
480 V
575 V
H
W
D
Weight
(lbs.)
List Price
RB3-1-S-027A-11C
24
7.5
10
20
25
14
10
7.7
14
$2,595.00
RB3-1-S-040A-11C
40
10
15
30
40
14
10
8.4
14
$2,625.00
RB3-1-S-052A-12C
52
15
20
40
50
14
10
9.2
17
$2,735.00
RB3-1-S-096A-13C
96
30
40
75
100
15
10
9.2
18
$3,575.00
RB3-1-S-125A-14C
125
40
50
100
125
21.5
12.3
9.7
43
$5,365.00
RB3-1-S-180A-15C
204
60
75
150
200
21.5
14.3
9.8
43
$6,585.00
RB3-1-S-361A-16C
252
75
100
200
250
23.9
13.4
10
56
$7,075.00
RB3-1-S-414A-17C
372
125
150
300
400
27.9
18
11.9
151
$8,900.00
RB3-1-S-590A-18C
551
200
200
450
500
28.9
18
11.9
159
$10,055.00
RB3-1-S-720A-19C
623
-
250
500
600
30.7
18
11.7
160
$10,055.00
Please allow 2 week lead time.
Unit requires separate 120 V control power.
Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.
4-12
benshaw.com
Return to the
Table of Contents
Open Chassis Solid State Starters
RC Series With MX 3
or MX 2 Technology
Non-Bypassed /
Continuous Duty,
1–1586 Amp / 600 VAC
Product Highlights:
The RC Series Solid State Starter combines the high performance MX2 or MX3 control
with the rugged, continuous duty, fan cooled RC stack.
The MX2 or MX3 series control provides users with a powerful group of programming
parameters, designed for flexibility in industrial applications. The MX2 and MX3 both
provide simple setup and commissioning via the Quick Start Menu.
The RC power section is a rugged non-bypassed section. It is an economical solution at low
horsepower. In addition, the fan cooled stack provides high duty cycle and high inertia starting
and energy saver operation.
Key Advantages:
• Economical at low horsepower
• High duty cycle starting
• Long starting times
• Modbus standard / Profibus, Ethernet,
DeviceNet, Ethernet IP web addressable
communication protocols are available
via optional communication bridges
• Suitable for jogging applications
• 1.25 service factor
• Fan cooled stack
• Integrated metering and diagnostics
• Integrated motor protection
• Multiple starting ramps
for various applications
Return to the
Table of Contents
4-13
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RC2 Series with MX 2 Technology
Non-Bypassed /Continuous Duty, 1–1586 Amp / 600 VAC
500% Current for 30 Sec. / 125% Continuous Rated
Horsepower
Dimensions (in.)
Model Number
A
208 V
240 V
480 V
575 V
H
W
D
Weight
(lbs.)
List Price
 RC2-0-S-027A-31C
27
7.5
10
20
25
14
9.9
7.9
15
$1,700.00
 RC2-0-S-040A-31C
40
10
15
30
40
14
9.9
7.9
15
$1,835.00
 RC2-0-S-052A-31C
52
15
20
40
50
14
9.9
7.9
18
$1,965.00
 RC2-0-S-065A-32C
65
20
25
50
60
18
10
9.6
18
$2,085.00
 RC2-0-S-077A-32C
77
25
30
60
75
18
10
9.6
18
$2,125.00
 RC2-0-S-096A-33C
96
30
-
75
100
27
10
9.6
19
$2,165.00
 RC2-0-S-125A-33C
125
40
50
100
125
27
10
9.6
45
$3,225.00
 RC2-0-S-156A-34C
156
50
60
125
150
24
22
10.1
45
$3,335.00
 RC2-0-S-180A-34C
180
60
75
150
200
24
22
10.1
45
$3,335.00
 RC2-0-S-240A-35C
240
75
100
200
250
26
22
10.1
55
$3,950.00
 RC2-0-S-302A-35C
302
100
125
250
300
26
22
10.1
55
$4,315.00
 RC2-0-S-361A-35C
361
125
150
300
400
26
22
10.1
60
$4,545.00
 RC2-0-S-414A-35C
414
150
-
350
-
26
22
10.1
150
$5,395.00
 RC2-0-S-477A-35C
477
-
200
400
500
26
22
10.1
150
$6,215.00
 RC2-0-S-515A-36C
515
200
-
450
-
36.8
29
10.7
150
$7,025.00
 RC2-0-S-590A-36C
590
-
250
500
600
36.8
29
10.7
160
$7,900.00
 Built-to-order: Please allow 2 weeks for shipment.
Unit requires separate 120 V control power.
Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.
4-14
benshaw.com
Return to the
Table of Contents
Open Chassis Solid State Starters
RC3 Series with MX 3 Technology
Non-Bypassed /Continuous Duty, 1–1586 AMP / 600 VAC
500% Current for 30 Sec. / 125% Continuous Rated
Horsepower
Dimensions (in.)
Model Number
A
208 V
240 V
480 V
575 V
H
W
D
Weight
(lbs.)
List Price
 RC3-0-S-027A-31C
27
7.5
10
20
25
14
9.9
8.7
15
$2,045.00
 RC3-0-S-040A-31C
40
10
15
30
40
14
9.9
8.7
15
$2,175.00
 RC3-0-S-052A-31C
52
15
20
40
50
14
9.9
8.7
18
$2,645.00
 RC3-0-S-065A-32C
65
20
25
50
60
18
10
10.4
18
$2,735.00
 RC3-0-S-077A-32C
77
25
30
60
75
18
10
10.4
18
$2,850.00
 RC3-0-S-096A-33C
96
30
-
75
100
27
10
10.4
19
$3,325.00
 RC3-0-S-125A-33C
125
40
50
100
125
27
10
10.4
45
$4,385.00
 RC3-0-S-156A-34C
156
50
60
125
150
24
22
10.9
45
$4,495.00
 RC3-0-S-180A-34C
180
60
75
150
200
24
22
10.9
45
$4,600.00
 RC3-0-S-240A-35C
240
75
100
200
250
26
22
10.9
55
$5,100.00
 RC3-0-S-302A-35C
302
100
125
250
300
26
22
10.9
55
$5,475.00
 RC3-0-S-361A-35C
361
125
150
300
400
26
22
10.9
60
$5,695.00
 RC3-0-S-414A-35C
414
150
-
350
-
26
22
10.9
150
$6,555.00
 RC3-0-S-477A-35C
477
-
200
400
500
26
22
10.9
150
$7,375.00
 RC3-0-S-515A-36C
515
200
-
450
-
36.8
29
11.5
150
$8,195.00
 RC3-0-S-590A-36C
590
-
250
500
600
36.8
29
11.5
160
$9,065.00
 Built-to-order: Please allow 2 weeks for shipment.
Unit requires separate 120 V control power.
Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.
Return to the
Table of Contents
4-15
Standard Low Voltage
Starter Products
Prepackaged Starters with ATL Bypass
RX Series with MX 3
or MX 2 Technology
Severe Duty 480 V / NEMA
12 or 3R / Combination /
Dual Redundant Starting
Product Highlights:
RX2E starters provide solid state reduced voltage starting for normal operation and
full voltage emergency backup starting with complete electronic motor protection
at the flip of a switch. This unique redundant design is the ideal solution for critical
applications where downtime is extremely disruptive to production operations and
cannot be tolerated. Benshaw’s MX solid state controls provide precise digital starting
and stopping, motor protection, metering, diagnostics and communications.
Units are stocked with MX2 technology, but are available with MX3 technology.
Standard Features:
• NEMA 12, redundant, combination / circuit breaker
• Shunt trip on main circuit breaker
• 500% – 30 seconds rated solid state starter, UL certified and listed
• 1800 PIV rated SCRs, UL certified and listed
• 125% continuous duty rated solid state starter, UL certified and listed
• Selector switch for selecting solid state or full voltage operation mounted
inside enclosure
• Full HP rated bypass contactor with a 1.15 service factor, wired for normal
bypass operation and full voltage start and run operation, with normally
open auxiliary contact
• Separately mounted "SPE" series overload relay wired for full voltage start
and run operation
• 110 volt control power transformer with primary and secondary fuses
• Door mounted start and stop push-buttons
• Door mounted keypad
• Door mounted run indicating light
• Door mounted local-off remote switch
• Door mounted overload reset
• Benshaw soft start and emergency bypass control board with customer connections
• Auxiliary relay with (2) Form C run contacts
• Benshaw MX2 programmable motor controller with soft start, soft stop and motor
protection capabilities
• RS485 ModBus communications
• Analog I/O
• Available with MX3 technology
4-16
benshaw.com
Return to the
Table of Contents
Prepackaged Starters with ATL Bypass
RX2E Series with MX2 Technology
Model Number
HP
CB
List Price
A
480 V
Trip
H
W
D
Weight
(lbs.)
$5,300.00  RX2E-050-480-3RKP
$5,800.00
65
50
125
26
24
12
215
 RX2E-075-480-12KP
$6,500.00  RX2E-075-480-3RKP
$6,835.00
96
75
175
26
24
12
220
 RX2E-100-480-12KP
$7,250.00  RX2E-100-480-3RKP
$7,955.00
124
100
225
48
24
12
230
 RX2E-125-480-12KP
$7,300.00  RX2E-125-480-3RKP
$8,625.00
156
125
250
48
24
12
320
 RX2E-150-480-12KP
$7,450.00  RX2E-150-480-3RKP
$8,755.00
180
150
300
48
24
12
325
$9,565.00  RX2E-200-480-3RKP
NEMA 12
List Price
 RX2E-050-480-12KP
NEMA 3R
Dimensions (in.)
$10,750.00
240
200
400
48
36
16
335
 RX2E-250-480-12KP
$10,525.00
 RX2E-250-480-3RKP
$11,750.00
302
250
500
70
30
18
510
 RX2E-300-480-12KP
$10,875.00
 RX2E-300-480-3RKP
$12,000.00
361
300
600
70
30
18
515
 RX2E-400-480-12KP
$14,000.00
 RX2E-400-480-3RKP
$16,750.00
477
400
800
87
37
20
765
 RX2E-500-480-12KP
$19,000.00
 RX2E-500-480-3RKP
$20,000.00
590
500
1200
87
37
20
790
 RX2E-600-480-12KP
$20,000.00
 RX2E-600-480-3RKP
$22,000.00
720
600
1200
87
37
20
815
HP
CB
 RX2E-200-480-12KP
RX3E Series with MX3 Technology
Model Number
NEMA 12
List Price
NEMA 3R
 RX3E-050-480-12KP
$6,395.00  RX3E-050-480-3RKP
Dimensions (in.)
List Price
A
480 V
Trip
H
W
D
Weight
(lbs.)
$6,755.00
65
50
125
26
24
12
215
 RX3E-075-480-12KP
$6,750.00  RX3E-075-480-3RKP
$7,335.00
96
75
175
26
24
12
220
 RX3E-100-480-12KP
$7,885.00  RX3E-100-480-3RKP
$8,365.00
124
100
225
48
24
12
230
 RX3E-125-480-12KP
$8,550.00  RX3E-125-480-3RKP
$8,955.00
156
125
250
48
24
12
320
 RX3E-150-480-12KP
$8,675.00  RX3E-150-480-3RKP
$9,085.00
180
150
300
48
24
12
325
$11,000.00
240
200
400
48
36
16
335
 RX3E-200-480-12KP
$10,775.00
 RX3E-200-480-3RKP
 RX3E-250-480-12KP
$11,725.00
 RX3E-250-480-3RKP
$12,000.00
302
250
500
70
30
18
510
 RX3E-300-480-12KP
$12,000.00
 RX3E-300-480-3RKP
$12,250.00
361
300
600
70
30
18
515
 RX3E-400-480-12KP
$16,500.00
 RX3E-400-480-3RKP
$17,000.00
477
400
800
87
37
20
765
 RX3E-500-480-12KP
$23,000.00
 RX3E-500-480-3RKP
$24,000.00
590
500
1000
87
37
20
790
 RX3E-600-480-12KP
$24,000.00
 RX3E-600-480-3RKP
$25,000.00
720
600
1200
87
37
20
815
50–600 HP units are service entrance rated.
 Built-to-order: Please allow one week for shipment.
 Web stocked
Available for same day shipping.
Return to the
Table of Contents
4-17
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PC / MX2PB
Series with MX 2
Technology
Non-Bypass / Continuous
Duty or Integral Bypass
Configure the MX2PB / MX2PC to fit your application
To choose a stock starter, simply select a unit from the following pages. We will ship
stock units ship the same day.
To modify a starter, select a unit from the following pages, then add an alpha board
and / or other options as needed from the Options section (see page 4-23). We will
modify the stock unit for next day shipment.
MX2PB / MX2PC configurable solid state starters stocked as:
• Non-combination
• Combination circuit breaker
• Rotary disconnect operator
• Non-bypass
• Bypass contactor
• NEMA 4 or 12 enclosure
• Modular operator station
• 480 V
• Standard 120 V control power transformer
• Service entrance rated with circuit breaker
• Door mounted key pad
Model shown is completely configured with all options.
(Stock
Unit
Shown)
1. Select a starter type:
4-18
2. Select a horsepower rating
5. Select a circuit breaker (or none)
• MX2PC modular non-bypass
3. Select a voltage
6. Select your options
• MX2PB modular bypassed
4. Select an enclosure
benshaw.com
Return to the
Table of Contents
Prepackaged Starters
MX2PB / MX2PC Series with MX 2 Technology
Part Number Assembler
MX2PB
SD
150
Starter Series
4
4
CB
Options
Enclosure
MX2PC
=
Modular
Non-Bypassed
MX2PB
=
Modular Bypassed
Duty Type
=
4
Standard Duty HP Rating
ST
NEMA 4/12
ST
=
Standard
OP
=
Options Included
Disconnect
Voltage
SD
=
Standard Duty
20
=
20 HP
4
=
480 V
NC
=
None
HD
=
Heavy Duty
30
=
30 HP
2
=
240 V
CB
=
Circuit Breaker
40
=
40 HP
50
=
50 HP
75
=
75 HP
100
=
100 HP
150
=
150 HP
200
=
200 HP
300
=
300 HP
400
=
400 HP
All units include 120 V control power transformer.
Return to the
Table of Contents
4-19
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PB Series with MX 2 Technology
Integral Bypass Non-Combination
240 V
Dimensions (in.)
Std. Duty1
HP
Heavy
Duty2 HP
V
H
W
D
Weight
(lbs.)
List Price
 MX2PB-015-2-4-NC **
15
15
240
24
16
15
110/3
$4,050.00
 MX2PB-020-2-4-NC **
20/25
20
240
24
16
15
110
$4,100.00
 MX2PB-030-2-4-NC **
30/40
30/40
240
36
16
15
150
$4,625.00
Model Number
 MX2PB-050-2-4-NC **
50
50
240
36
20
15
150
$4,850.00
 MX2PB-075-2-4-NC **
60/75
60/75
240
48
20
15
180
$5,050.00
 MX2PB-100-2-4-NC **
100
–
240
48
20
15
180
$5,225.00
 MX2PB-150-2-4-NC **
150
100
240
48
20
15
180
$6,045.00
 MX2PB-200-2-4-NC **
200
150
240
78
30
20
350
$8,300.00
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Built-to-order
480 V
Dimensions (in.)
Std. Duty1
HP
Heavy
Duty2 HP
V
H
W
D
Weight
(lbs.)
List Price
 MX2PB-030-4-4-NC **2
30
30
480
24
16
15
110
$4,050.00
 MX2PB-050-4-4-NC **2
50
40
480
24
16
15
110
$4,100.00
 MX2PB-075-4-4-NC **2
75
75
480
36
16
15
150
$4,625.00
 MX2PB-100-4-4-NC **2
100
–
480
36
20
15
150
$4,850.00
 MX2PB-150-4-4-NC **2
150
150
480
48
20
15
180
$5,050.00
 MX2PB-200-4-4-NC **2
200
–
480
48
20
15
180
$5,225.00
 MX2PB-300-4-4-NC **2
300
200
480
48
20
15
180
$6,045.00
 MX2PB-400-4-4-NC **2
400
300
480
78
30
20
350
$8,300.00
Model Number
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Available for same day shipment, or modified for next day shipment.

Web stocked
4-20
benshaw.com
Return to the
Table of Contents
Prepackaged Starters
MX2PB Series with MX 2 Technology
Integral Bypass Combination Circuit Breaker
240 V
Dimensions (in.)
Std. Duty1
HP
Heavy
Duty2 HP
V
H
W
D
Weight
(lbs.)
List Price
 MX2PB-020-2-4-CB **
20/25
20
240
36
16
15
175
$5,150.00
 MX2PB-030-2-4-CB **
30/40
30/40
240
42
20
15
200
$5,325.00
 MX2PB-050-2-4-CB **
50
–
240
48
24
15
220
$5,695.00
 MX2PB-075-2-4-CB **
60/75
60/75
240
48
24
15
220
$6,325.00
 MX2PB-100-2-4-CB **
100
–
240
48
24
15
220
$6,675.00
 MX2PB-150-2-4-CB **
150
100
240
48
24
15
220
$8,375.00
 MX2PB-200-2-4-CB **
200
150
240
78
30
24
400
$10,450.00
Model Number
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Built-to-order: Please allow 2 week lead time.
480 V
Dimensions (in.)
Std. Duty1
HP
Heavy
Duty2 HP
V
H
W
D
Weight
(lbs.)
List Price
 MX2PB-050-4-4-CB **2
50
40
480
36
16
15
175
$5,150.00
 MX2PB-075-4-4-CB **2
75
75
480
42
20
15
200
$5,325.00
 MX2PB-100-4-4-CB **2
100
–
480
48
24
15
220
$5,695.00
 MX2PB-150-4-4-CB **2
150
150
480
48
30
15
220
$6,325.00
 MX2PB-200-4-4-CB **2
200
–
480
48
30
15
220
$6,675.00
 MX2PB-300-4-4-CB **2
300
200
480
48
30
15
220
$8,375.00
 MX2PB-400-4-4-CB **2
400
300
480
78
30
24
400
$10,450.00
Model Number
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Available for same day shipment, or modified for next day shipment.

Web stocked
Model Number
Description
KPMX3CBL2M
NEMA 12 / 3R Remote Keypad
with 2 Meter Cable
Return to the
Table of Contents
List Price
$425.00
4-21
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PB / MX2PC Series With MX 2 Technology
Options
Option Code
Space Heater Option
List Price
U4
Space Heater with Thermostat
Option Code
Control Options (only one code can be selected)
QN
Run Light
QF
Reset Push-Button
CP
Start / Stop Push-Buttons
$175.00
CQ
Start / Stop Push-Buttons and Run Light
$235.00
CR
Start / Stop Push-Buttons, Run Light, Fault Light
and Reset Push-Button
$500.00
RK
Fault Light
$125.00
CS
Fault Light and Reset Push-Button
$210.00
CT
Run Light, Fault Light and Reset Push-Button
$335.00
CU
HOA and Start / Stop Push-Buttons
$325.00
CV
HOA, Start / Stop Push-Buttons and Run Light
$445.00
CW
HOA, Start / Stop Push-Buttons, Run Light, Fault Light and Reset Push-Button
$655.00
Option Code
Communications Options
$445.00
List Price
$125.00
$85.00
List Price
CD
Profibus

CE
DeviceNet

CF
Ethernet

CG
Lon Works

CH
IP Internet Web Addressable

CC
RS232 Connector — Allows User to Connect Remotely without Opening the Encl. Door

Consult factory
4-22
benshaw.com
Return to the
Table of Contents
Engineered Low Voltage
Starter Packages
Overview
Benshaw has developed advanced engineering, drafting, materials management and quality systems focused on designing and building customer
solutions. This "Engineered-to-Order" capability, combined with an extensive inventory of control components, protective relays, circuit breakers,
contactors, enclosures and other electrical / electronic devices, enables Benshaw to quickly ship engineered products.
Control Modifications — Whatever You Specify:
• Over 250 modifications and accessories are available, including: pilot devices,
PLCs, control power transformers, switches, meters, relays, space heaters,
and protective devices.
Combination Starters — To Meet Your Requirements:
• 15 to 2000 amp circuit breakers
• 40 to 2000 amp non-fused disconnects
• 30 to 800 amp fusible disconnect
• Flange or rotary handle mechanism
Power Stacks — To Fit Your Application:
• Continuous duty / non-bypassed
• Integral bypass
• Standard, heavy and severe duty
• Emergency across-the-line bypass
Enclosures — To Match Your Environment:
• Standard designs — NEMA 1, 12, 4 chassis
• Custom enclosures
• Special enclosures — 3R, 4X, 7, 9, as specified
• Motor control centers
Communication
• ModBus / RS485
Benshaw quickly ships engineered products.
Return to the
Table of Contents
4-23
Engineered Low Voltage
Starter Products
Wound Rotor Starters
RATINGS
Horsepower:
20–1500 HP
Overload:
500% for 30 seconds
125% continuous
Starting Torque:
0–100%
Voltage:
200–1000 VAC
Typical Resistance Steps:
1-2
Product Highlights:
Wound rotor motors are typically used in applications requiring high starting torques,
a limited number of operating speeds, or a stepped acceleration to achieve a soft
start. Typical existing applications utilize an electromechanical starter on the stator
and introduce multiple stages of resistance in the rotor via contactor arrangements
to achieve a soft ramp.
With the RediStart MX3, wound rotor control is greatly simplified. The RediStart
consists of two major sections: 1) A solid-state stator control, and 2) secondary
resistors into the rotor circuit from a separate 3-phase resistor bank. This achieves
the high torque required by the application—with low inrush—while providing a
smooth stepless start. This greatly reduces the maintenance cost of the typical
electromechanical control.
Single Step Rotor Control: The solid-state starter is wired to the motor stator circuit,
and the resistor and shorting contactor are wired to the motor rotor circuit. The solid
state starter accelerates the motor to slip speed (determined by the resistance value)
and then activates the contactor to short the rotor. This allows the motor to accelerate
to full speed.
Multiple Step Rotor Circuit: WR RVSS series starters can be supplied with multiple
stages of rotor resistor and contactor combinations. This arrangement may be
necessary for multiple step starting of extremely high inertia loads, or for continuous
operation at multiple speeds. Multiple steps of rotor resistance can be coordinated
to achieve this.
Variable Speed Control: Variable speed control of wound rotor motors can be
accomplished with the RediStart series control. By maintaining full output voltage of
the control going to the stator of the wound rotor motor, and varying the resistance
in the rotor, variable speed is accomplished.
Resistors must be rated for continuous duty operations. Variable loads (pumps and
fans) only.
Key Advantages:
• Benshaw MX3 technology
• Modbus capable
• Single step rotor control
• Configurable output relays
• Modular power stack design
• Multistep and variable speed
for ease of maintenance
• Integral bypass contactor design
• Reduced maintenance
• Advanced MX motor protection
• Reduced in size and number
3
• Advanced MX3 metering function
• Real time clock
• 99 event log history
4-24
benshaw.com
rotor control available
of resistors needed
• Stepless control
• Reduces inrush while
maintaining torque
Return to the
Table of Contents
Wound Rotor Motor Starter Check List
Present starting
 Across the line
method
 Other ___________________________________
Rotor circuit
information
Present number of steps of
resistance ____________
Total starting ohm value
____________ ohms
Current
method of
resistance
shorting
Step one ____________ sec.
Step two _________ sec.
Step three______ sec.
Step four _____ sec.
Step five ____ sec.
The present number of steps may be more or less than listed above. Please specify.
Motor
information
Primary
voltage______________
Secondary
voltage_______________
Primary
amps________________
Secondary
amps_________________
RPM ________________
Service
Factor________________
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Return to the
Table of Contents
4-25
Engineered Low Voltage
Starter Products
Synchronous Starters
SEP Series
RATINGS
Horsepower:
20–1500 HP
Overload:
500% for 30 seconds
125% continuous
Starting Torque:
0–100%
Voltage:
200–1000 VAC
Includes discharge resistor
and synchronous excitation
package for brush type and
brushless motor.
Exciter Ratings:
125–250 VDC
30–120 A*
Product Highlights:
The sync motor functions as an induction motor during start up. Once the motor
approaches full synchronous speed, the Redistart DC exciter induces a constant
polarity to the rotor causing the motor to lock into sync. Because the rotor’s field
is constant and separately excited, there is no slip required to produce torque,
as with an induction motor. This allows the motor to run at synchronous speed.
The Benshaw synchronous package consists of a solid state starter portion connected
to the stator and an SEP (synchronous excitation package) that is connected to the
rotor section in conjunction with a discharge resistor. This SEP is supplied for brush
type and brushless exciters.
Synchronous Benefits:
The RediStart series solid state starter provides reduced voltage stepless acceleration
and automatic synchronization of three phase AC synchronous motors. Synchronous
motors are utilized for a number of reasons. They are used in applications that require
precise motor speed, they are used to obtain greater efficiencies and they are used
for facility power factor correction.
Since synchronous motors can be operated at leading power factor, they are used
to correct a facility’s lagging power factor created by all the other induction motors
being operated.
This correction reduces the penalty a customer pays the utility company for creating
poor power factor.
Key Advantages:
• Benshaw synchronous technology
• Modbus communication
• Solid state synchronous rotor control
• Configurable output relays
• Modular power stack design
• Reduced maintenance
for ease of maintenance
• Integral bypass contactor design
• Advanced synchronous
* Consult factory for higher Amp rating.
motor protection
• Can be added to
existing equipment
• Can be supplied with MX2
• Reduction in size compared
to existing field control
• Stepless control
• Reduces inrush while
maintaining torque
• Brush type and brushless control
or MX3 starter control
4-26
benshaw.com
Return to the
Table of Contents
Synchronous Motor Starter Check List
Present starting
 Across the line
method
 Other please specify ______________________
Application _______________________
Field discharge resistor value____________ohms
Motor
information
Motor horsepower__________
Motor frequency ________Hz
Field voltage_______________
Max field current __________
Full load current____________
Motor LRA________________
RPM______________________
Service Factor_____________
Motor Wk2 ________________
Load Wk2_________________
Motor voltage________
Motor Speed ____RPM
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Options :
 Brushless exciter or
 Brush Type exciter
 Circuit Breaker
 Fusible Switch
 No disconnect needed
 Bypass contactor run duty only
 120 VAC control power by Benshaw
 Start Stop Pushbutton
 Hand Off Auto
Return to the
Table of Contents
 Local Off Remote
 2-Wire Control
 3-Wire Control
4-27
Engineered Low Voltage
Starter Products
Solid State Starters with Reversing Control
RB2 / RB3 Series
RATINGS
Horsepower:
20–1500 HP
Benshaw also offers a microprocessor controlled solid state reduced voltage reversing
starter for three phase induction motors. This starter provides a closed loop current
ramp for smooth stepless motor acceleration. The RediStart reversing starter is offered
with a reversing contactor set.
Key Advantages:
• Benshaw MX2 or MX3 technology with reversing contactor control
• Available with DC injection brake
Overload:
500% for 30 seconds
125% continuous
Starting Torque:
0–100%
• Modular power stack design for ease of maintenance
• Integral bypass contactor design
• Advanced MX2 or MX3 motor protection
• Advanced MX2 or MX3 metering function
• Real time clock (MX3 only)
• 99 event log history (MX3 only)
• ModBus communication
Voltage:
200–1000 VAC
4-28
Product Highlights:
benshaw.com
• Configurable output relays
• Reduced maintenance
Return to the
Table of Contents
Solid State Starters with Two Speed Control
MX 2 / MX 3 Series
RATINGS
Horsepower:
Product Highlights:
These RediStart solid state starters provide reduced voltage stepless control of two
speed three phase AC induction motors.
The two speed starter can be used with two speed, two winding motors. It contains
a ten SCR power section or it can be used with two speed, single winding motors.
20–1500 HP
The logic control incorporates MX2 or MX3 technology with all the circuitry required
to drive the power semiconductors located in the power section.
Overload:
Benshaw RediStart two speed starters are electronically interlocked so that a start
cannot be initiated at one speed if the starter is already running in another.
500% for 30 seconds
125% continuous
Key Advantages:
Starting Torque:
0–100%
Voltage:
200–1000 VAC
Two Speed Two Winding
Two Speed One Winding
• Benshaw MX2 or MX3 series control
• Two speed one winding or two speed two winding available
• Modular power stack design for ease of maintenance
• Reversing available
• Integral bypass contactor design
• Advanced MX2 or MX3 motor protection
• Advanced MX2 or MX3 metering function
• Real time clock (MX3 only)
• 99 event log history (MX3 only)
• ModBus communication
• Configurable output relays
• Reduced maintenance
Return to the
Table of Contents
4-29
Engineered Low Voltage
Starter Products
Solid State Starters
Engineered Packages
Part Number Assembler
R
B
2
1
Starter Series
=
R
=
Bypass
Contactor
C
=
Continuous
Control
3
4-30
=
MX
Technology
0
benshaw.com
S
208
=
208 V
H
=
High
240
=
240 V
480
=
480 V
575
=
575 V
None
=
Integral
=
Separate,
Definite
Purpose
3
=
Separate ATL
IEC Rated
4
=
Separate ATL
NEMA Rated
NC
ST
Disconnect Option
Standard
1
04
Voltage
=
2
2
MX3
Technology
DC Injection
Braking
=
480
S
Type of Bypass
B
=
100
Interrupt Rating
RediStart
Configuration
2
S
NC
=
NonCombination
CB
=
Circuit Breaker
FD
=
Fusible
Disconnect
Options
Horsepower
Power Stack Rating
1
=
1 HP
2
=
2 HP
3
=
3 HP
5
=
5 HP
7
=
7.5 HP
10
=
10 HP
15
=
15 HP
20
=
20 HP
25
=
25 HP
30
=
30 HP
40
=
40 HP
50
=
50 HP
60
=
60 HP
75
=
75 HP
100
=
100 HP
125
=
125 HP
150
=
150 HP
200
=
200 HP
250
=
250 HP
300
=
300 HP
400
=
400 HP
500
=
500 HP
600
=
600 HP
700
=
700 HP
800
=
800 HP
900
=
900 HP
1000
=
1000 HP
ST
=
Standard
OP
=
Options
Included
S
=
350% 30
Seconds
H
=
500% 30
Seconds
Enclosure
V
=
600% 30
Seconds
OC
=
Open
Chassis
1
=
NEMA 1
12
=
NEMA 12
4
=
NEMA 4
3R
=
NEMA 3R
Return to the
Table of Contents
Wye Delta Starters
Smart Wye-Delta Starter Kits..............5-2
Return to the
Table of Contents
5-1
Wye Delta Starters
Smart Wye-Delta Starter Kits
Wye Delta Starters
Product Highlights:
Benshaw’s MX2 control technology provides an innovative way to bring powerful,
flexible, intelligent low voltage motor control to traditional non-intelligent wye
delta electro-mechanical starters. MX2-based controls offer multiple, user
selectable modes, an increased selection of configurable analog and digital
I/Os, comprehensive metering capabilities, unprecedented on-board protections
and an easy to use interface.
Benshaw’s MX2 technology makes for an excellent alternative to traditional electromechanical wye delta starters. The transition from wye to delta is controlled by the
solid state circuitry to ensure ease in setting up the wye delta starter parameters to
match your application.
With more built-in starting modes, more built-in metering, protection features and
additional communication capabilities, Benshaw’s MX2-based low voltage wye delta
starters raise the bar for intelligent, low cost wye delta controls.
Control Features: (Partial)
Motor Protection
Metering
• Motor thermal overloads
• Average current
• Up to speed time exceeded
• L1 current
• Low line voltage
• L2 current
• Low line frequency
• L3 current
• High line frequency
• Current imbalance %
• Phase reversal
• Ground fault amps / residual
• Phase loss
• Average or phase volts
• Instantaneous
• Overcurrent power factor
• Over current
• Watts
• Under current
• VA
• Current imbalance
• kW hours
Benshaw’s SMART wye delta starters are available in both non-combination and
combination packages and NEMA 1, 12, 3R and 4 enclosures. All UL listed and NEMA
compliant. Many options and accessories can be added; please consult factory with
your specific needs.
5-2
benshaw.com
Return to the
Table of Contents
Smart Wye-Delta Starter Kits
Smart Wye Delta
Starter Max Amps
Model Number
Description
1559
FS-SMYD-MX-00-XX
Smart Wye-Delta Starter Kit, 1559A, 200–575V
Enclosure Size (in.)
86x72x24
1143
FS-SMYD-MX-01-XX
Smart Wye-Delta Starter Kit, 1143A, 200–575V
86x72x24
779
FS-SMYD-MX-02-XX
Smart Wye-Delta Starter Kit, 779A, 200–575V
79x40x20
606
FS-SMYD-MX-03-XX
Smart Wye-Delta Starter Kit, 606A, 200–575V
79x40x20
476
FS-SMYD-MX-04-XX
Smart Wye-Delta Starter Kit, 476A, 200–575V
70x30x18
398
FS-SMYD-MX-05-XX
Smart Wye-Delta Starter Kit, 398A, 200–575V
70x30x18
364
FS-SMYD-MX-06-XX
Smart Wye-Delta Starter Kit, 364A, 200–575V
48x36x16
277
FS-SMYD-MX-07-XX
Smart Wye-Delta Starter Kit, 277A, 200–575V
48x36x16
217
FS-SMYD-MX-08-XX
Smart Wye-Delta Starter Kit, 217A, 200–575V
48x36x16
156
FS-SMYD-MX-09-XX
Smart Wye-Delta Starter Kit, 156A, 200–575V
48x24x12
139
FS-SMYD-MX-10-XX
Smart Wye-Delta Starter Kit, 139A, 200–575V
48x24x12
130
FS-SMYD-MX-11-XX
Smart Wye-Delta Starter Kit, 130A, 200–575V
48x24x12
104
FS-SMYD-MX-12-XX
Smart Wye-Delta Starter Kit, 104A, 200–575V
48x24x12
78
FS-SMYD-MX-13-XX
Smart Wye-Delta Starter Kit, 78A, 200–575V
48x24x12
69
FS-SMYD-MX-14-XX
Smart Wye-Delta Starter Kit, 69A, 200–575V
48x24x12
XX denotes enclosure type e.g. 1, 12, 3R or 4.
Smart Wye Delta – Combination Circuit Breaker
Starter Max Amps
Model Number
Description
Enclosure Size (in.)
1559
FS-SMYD-MX-00-XX
Smart Wye-Delta Starter Kit, 1559A, 200–575V
86x72x24
1143
FS-SMYD-MX-01-XX
Smart Wye-Delta Starter Kit, 1143A, 200–575V
86x72x24
779
FS-SMYD-MX-02-XX
Smart Wye-Delta Starter Kit, 779A, 200–575V
79x40x20
606
FS-SMYD-MX-03-XX
Smart Wye-Delta Starter Kit, 606A, 200–575V
79x40x20
476
FS-SMYD-MX-04-XX
Smart Wye-Delta Starter Kit, 476A, 200–575V
70x30x18
398
FS-SMYD-MX-05-XX
Smart Wye-Delta Starter Kit, 398A, 200–575V
70x30x18
364
FS-SMYD-MX-06-XX
Smart Wye-Delta Starter Kit, 364A, 200–575V
48x36x16
277
FS-SMYD-MX-07-XX
Smart Wye-Delta Starter Kit, 277A, 200–575V
48x36x16
217
FS-SMYD-MX-08-XX
Smart Wye-Delta Starter Kit, 217A, 200–575V
48x36x16
156
FS-SMYD-MX-09-XX
Smart Wye-Delta Starter Kit, 156A, 200–575V
48x24x12
139
FS-SMYD-MX-10-XX
Smart Wye-Delta Starter Kit, 139A, 200–575V
48x24x12
130
FS-SMYD-MX-11-XX
Smart Wye-Delta Starter Kit, 130A, 200–575V
48x24x12
104
FS-SMYD-MX-12-XX
Smart Wye-Delta Starter Kit, 104A, 200–575V
48x24x12
78
FS-SMYD-MX-13-XX
Smart Wye-Delta Starter Kit, 78A, 200–575V
48x24x12
69
FS-SMYD-MX-14-XX
Smart Wye-Delta Starter Kit, 69A, 200–575V
48x24x12
XX denotes enclosure type e.g. 1, 12, 3R or 4.
Return to the
Table of Contents
5-3
Wye Delta Starters
Smart Wye-Delta Starter Kits
Basic Wiring Diagram
5-4
benshaw.com
Return to the
Table of Contents
Pump Control Starters
Prepackaged Full Voltage Starters
with Door Mounted Controls..............6-2
Engineered / Configurable
Pump Panels.......................................6-4
Return to the
Table of Contents
6-1
Pump Control Starters
Prepackaged Full Voltage Starters
With Door Mounted Controls
RCI Series
Non-Combination /
Combination / NEMA
12/3R / Electronic
Overload Protection
• Control Terminal Block
• Fused Control Power
Transformer
• Grounding Lug
Product Highlights:
RCI starters are NEMA Rated, cUL listed, completely integrated, full voltage/nonreversing starter packages. The rugged NEMA 12/3R design is ideal for Industrial Duty
Applications such as pumps, compressors, conveyors, fans and any other continuous
duty equipment. The “three wires in/out” design includes the Benshaw SPE, field
adjustable electronic overload relay, which enables quick installation and startup with
precision motor protection...standard.
Rugged. Reliable. Ready.
Key Advantages:
• cUL listed
• NEMA rated, heavy duty contactors
• NEMA 12/3R enclosure
• Field adjustable SPE electronic overload relay
• Two year warranty - standard
• Complete door mounted operator control package
• Circuit Breaker with Operator
CBRCI (Type)
• NEMA Rated Contactor
• 480/240: 120 fused control power transformer
• “Three wires in/out” installation and startup
• Combination or non-combination
• SPE Electronic Overload Relay
Provided with SPE Electronic Overload Relay
SPE electronic overload relays provide field adjustable,
precise motor protection, including:
• Adjustable overload class (1–30)
• Wide range of current adjustments
• 1 NO and 1 NC auxiliary contact
• Current imbalance detection
• Phase loss detection
• Phase reversal protection
• Trip free design
• Test function/trip indication
• Fault indication
6-2
benshaw.com
SPE Electronic Overload Relay
Return to the
Table of Contents
Prepackaged Full Voltage Starters
With Door Mounted Controls
NCRCI Non-Combination Full Voltage Non-Reversing Starters
CBRCI Combination Full Voltage 480V Non-Reversing Starters
CBRCI Combination Full Voltage 240V Non-Reversing Starters
• NEMA 12/3R enclosure
• Door-mounted start
and stop push-buttons
• cUL listed
• Door-mounted overload
• NEMA rated contactor and,
reset push-button
separately mounted SPE
overload relay
• Red run indicator light
• 480/240:120 fused control
• (2) Auxiliary contacts
power transformer
• Hand off auto selector switch
NCRCI
CBRCI
NCRCI — 240V or 480V
NEMA Horsepower
NEMA Size
240V
480V
Dimensions (in.)
Weight
List Price
 NCRCI93R 1,2,4
Model Number
00
1.5
2
14 x 10 x 7
30
$1,055.00
 NCRCI183R 1,2,4
0
3
5
12 x 10 x 8
30
$1,075.00
 NCRCI323R 1,2,4
1
7.5
10
12 x 10 x 8
32
$1,095.00
 NCRCI503R 1,2,4
2
15
25
16 x 12 x 9
32
$1,200.00
 NCRCI853R 1,2,4
3
30
50
16 x 12 x 9
60
$1,250.00
 NCRCI1503R 1,2,4
4
50
100
16 x 12 x 9
60
$1,945.00
 Web stocked
CBRCI — 480V
Model Number
NEMA Size
CB Trip
NEMA HP
Dimensions (in.)
Weight
List Price
 CBRCI9-4-3R 1,4
00
15
2
20 x 16 x 10
48
$1,495.00
 CBRCI18-4-3R 1,4
0
20
5
20 x 16 x 10
48
$1,525.00
 CBRCI32-4-3R 1,4
1
30
10
24 x 12 x 10
63
$1,725.00
 CBRCI50-4-3R 1,4
2
70
25
30 x 12 x 10
63
$1,895.00
 CBRCI85-4-3R 3,4
3
100
50
36 x 16 x 10
125
$2,225.00
 CBRCI150-4-3R
3,4
4
200
100
36 x 16 x 10
125
$2,375.00
 CBRCI300-4-3R
3,4
5
400
200
48 x 24 x 16
250
$4,225.00
NEMA Size
CB Trip
NEMA HP
Dimensions (in.)
Weight
List Price
00
15
1.5
20 x 16 x 10
48
$1,495.00
0
20
3
20 x 16 x 10
48
$1,525.00
1
40
5
24 x 12 x 10
63
$1,725.00
1
50
7.5
24 x 12 x 10
63
$1,725.00
$1,895.00
 Web stocked
CBRCI — 240V
Model Number
CBRCI9-2-3R
1,5
CBRCI18-2-3R 1,5
CBRCI32-5-2-3R
1,5
CBRCI32-7.5-2-3R
1,5
3,5
2
70
15
30 x 12 x 10
63
CBRCI85-2-3R 3,5
3
125
30
36 x 16 x 10
125
$2,225.00
CBRCI150-2-3R 3,5
4
200
50
36 x 16 x 10
125
$2,375.00
CBRCI50-2-3R
1) Units can be shipped via air and/or parcel.
2) Units are built as 480V w/dual tap transformer and fusing for 240 volt.
3) Units cannot be shipped via air - they must ship by common carrier.
4) Units are in stock.
5) Units are not stocked - allow 2 weeks for shipping.
Return to the
Table of Contents
6-3
Pump Control Starters
Engineered / Configurable Pump Panels
Engineered /
Configurable —
Combination Full
Voltage Starters /
NEMA 3R
NEMA Size 1–6 / NEMA 3R
Enclosed (with Solid State
Overload Protection)
Product Highlights:
Benshaw’s pump control panels are UL listed and are available as NEMA HP rated.
A NEMA 3R enclosure design makes these panels ideal for a wide range of heavy
duty pumping and irrigation applications.
Al panels are service entrance "SUSE" rated and backed by Benshaw’s unmatched
quality and 24/7 service.
Heavy duty performance, low cost and configurability make these pump control panels
an exceptional value. Choose a standard configuration or select options from the list
of factory modifications on page 6-7.***
Standard Features:
• 240/480 volt, three phase
• Heavy duty fusible switch or circuit breaker (low profile)*
• Class R fuse clip**
• Flange operated disconnect
• Solid state overload and pump protection (Class 10)
• HOA switch
• Start push button
• Outdoor rated NEMA 3R enclosure
• Oversized panel
• Defeatable disconnect
• UL listed panel
• Ground lug
• Service entrance rated
Factory Modified Options:
• Pre-wired motor and pump protector relay
• Power surge lightning protection
• Pre-wired time clock (24hr)
• Pre-wired control transformer (120 V)
• Electronic overload phase protection relay
• Pre-wired panel heater
• Disconnect switch interlock
• Circuit breaker shunt trip
• Back spin protection
• Elapsed time meter
• Power, run and fault indicator lights
• Extra capacity CPT 100 or 150 VA
* 240 V units are built to order. Please allow two weeks for shipment.
** Fuse not provided. Recommend Class R type, dual element delay.
*** Consult factory for additional details on a variety of options.
6-4
benshaw.com
Return to the
Table of Contents
Engineered / Configurable Pump Panels
Factory Options
Factory modifications are available for all Benshaw pump panels.
Pilot Devices Options
Advanced Motor Protection Options
Standard Capacity Options
• Run Pilot Light (Red)
• Electronic Overload (Class 1~30)*
• 240 V Primary
• Run Pilot Light (Green)
• Digital Overload (Class 1~60)*
• 480 V Primary
• Off Pilot Light (Green)
• Pump Saver 777 - Voltage Current
Protection
• Off Pilot Light (Red)
• Pump Saver 777 - LR - kW Protection
• OL Trip Pilot Light (Yellow)
• On Pilot Light (Red)
• On Pilot Light (Green)
Extra Auxiliary Contact Blocks Options
• Factory Installed 1 N/O and 1 N/C
• Factory Installed 2 N/O and 2 N/C
Meters Option
• Elapsed Time Meter (Analog,
Non-Resettable)*
* Requires 120 V control power.
150VA Extra Capacity Options
• 240 V Primary
• 480 V Primary
Pilot lights are full voltage supplied at same
voltage as contactor coil.
Enclosure Mounted Options
• Lightning Surge Protector
• Time Clock 24Hr.
• Space Heater*
• Disconnect Switch Interlock
• Back Spin Protection*
* Requires 120V control power.
Return to the
Table of Contents
6-5
Notes
6-6
benshaw.com
Return to the
Table of Contents
Notes
Return to the
Table of Contents
6-7
Notes
6-8
benshaw.com
Return to the
Table of Contents
Variable frequency.
Unchanging innovation.
Introducing the M2L 3000 Series
Medium Voltage Variable Frequency Drive.
The M2L 3000 Medium Voltage Variable Frequency Drive is a step change
in motor control power technology. Though designed for industrial
applications, it benefits from Benshaw’s wide ranging experience in defense
Benefits of the M2L 3000 include:
• Compact Modular Design
and nuclear-related technologies, an arena where products must meet the
• Arc Resistant
most rigorous standards and where failure is simply not an option.
• Installation Flexibility
Our innovative patented topology — modular multilevel converter (M2LC)
• Energy Efficiency
— is powered by state-of-the-art hardware and software control. Our
• Robust Control Architecture
control algorithms are setting the stage for the next generation of VFDs.
Developed, designed and
manufactured in the USA.
Supported around the globe.
To learn more about the M2L 3000,
visit http://benshaw.com,
call 412-968-0100 or e-mail
BenshawRFI@regalbeloit.com
24/7 Technical Support
Repairs
Benshaw is dedicated to providing
comprehensive 24-hour-a-day, 7-day-a-week
phone support. Benshaw provides repair,
spare parts, field engineering, retrofit and
training services, when and where you need
us. You can count on our experienced team,
backed by the latest diagnostics and repair
tools and an extensive parts inventory to
support your operations.
Call 1.800.203.2416
Repairs are made on Benshaw equipment by trained, experienced
personnel, using the latest diagnostic and test equipment.
Field Services are performed on-site by skilled technicians,
engineers or complete teams if needed, including:
• Start-up commissioning
• Field repairs
• Field analysis/data collection
• Preventative maintenance
24/7 Hotline Support from our operations
in Pittsburgh and Listowel (Canada):
• Retrofits
• Technical phone support
The Benshaw Product Line
• Overnight parts shipment
A wide range of motor controls and drives is available.
• 24-hour service dispatch
• Solid-state starters fractional up to 30,000HP at 15kV
• Coordination of all service capabilities
• LV AC drives to 2,000HP, MV AC drives to 10,000HP
• Electromechanical controls to 800A
Benshaw Express is a 24/7 online inventory and
order entry system for authorized Benshaw distributors:
• 24/7 shipment
• Air or truck delivery
Visit us online at
benshaw.com and
benshawexpress.com,
or contact:
BENSHAW, Inc.
615 Alpha Drive
Pittsburgh, PA 15238
Phone: 412.968.0100
Fax: 412.968.5415
BENSHAW Canada
550 Bright Street East
Listowel, Ontario N4W 3W3
Phone: 519.291.5112
Fax: 519.291.2595
Specifications are subject to change without notice.
©2015 Regal-Beloit Corporation MKT 125-013R Printed in the USA
A Regal Brand
www.regalbeloit.com
Download