The Waterfront Theatre Technical Specifications Contacts: GICS

advertisement
The Waterfront Theatre
Technical Specifications
Contacts:
GICS Office:
604-687-3005
website:
waterfronttheatre.ca
Production Manager / Emergency Contact:
Miles Lavkulich
(Ext. 1502)
Theatre Services Manager:
Jim Travis
(Ext. 1503)
Securiguard – evening security (1900-0700): 604-315-3003
Mailing Address:
101 - 1398 Cartwright St., Granville Island, Vancouver, B.C., V6H 3R8
Building Address: 1412 Cartwright St., Vancouver, B.C., V6H 3R7 Building phone: 604 685-1731
February 3/2015 ML
Stage:
DS opening, max proscenium width (hard)
~41’ 9”
Standard Stage width, leg to leg
~30’
Stage depth total from stage edge to US wall
~23’ 10”
Stage depth to removable US crossover
~20’ 6”
Depth from FOH catwalk to cyc
~35’
Height to fixed grid above stage
~21’ 11”
Height to ceiling above stage ( roof)
~25’ 6”
Height to bottom of onstage catwalk from stage
~17’ 10”
Width from onstage Pillar SL to Pillar SR
~39’
-Stage floor is masonite covered, screwing into floor is permitted, subject to approval.
-Painting the floor is permitted, subject to approval by GICS PM, and must be restored
Loading Area:
Loading door
9’8”w x 9’11”h, 3’ above street level on SR side of theatre (east)
Dressing Rooms:
Stage level
Upper level
Green room / dressing room ~10’x18’
Two dressing rooms ~6’x14’ (4-6 people each)
Two washrooms with showers
Washer/ dryer located in one dressing room
Both dressing rooms are equipped with mirrors, counters, makeup
lights and clothing racks.
Front of House:
Auditorium
Lighting:
Dimmers
224 persons (14 rows of 16 seats)
Front row is removable to accommodate up to10 wheelchairs
Booth may be moved into house, uses 10 seats
Lobby
~20’ x 26’ (with stairway and bar obstructions)
Foyer (box office)
~10’ x 32’
-See contract for box office, bar and usher staff requirements
-all lobby displays must be approved by the GICS Theatre Services Manager
ETC 96 rack with 95 x 2.4k dimmers (+one dedicated HS LX)
50A range plug is located in dimmer room below booth
Control
ETC ION (20 subs, 1024 channels) with touch screen
Circuits
12 x 6 circuit Soca, (20 Amp TLG) from patch panel, 96 available
Instruments
53 – S4 leko’s (17 x 26, 17 x 36, 16 x 50)
Extra S4 barrels 4 x 19, 2 x 90, 1 x 70, 1 x 10)
4 – S4 PAR 575w /w scrollers
29 - Colour Blast v1.0 LED 10 degree lens
12 - ETC S4 PAR Wide) /w lens kits & barn doors)
19 - ParCans (19 - MFL 1K, 19 – WFL IK)
1 - Altman follow spot (1K)
2 - I-Cue mirrors with DMX Iris for S4
2 – Mac Martin 350’s
-House plot uses (including specials) 4 x S4 PAR with scrollers, 29 LED, 12 x S4 PAR
12 x 50deg., 9 x 36deg. and 8 x 26deg.
-WFT has a house lighting and masking plot, any changes must be restored during the strike
The Waterfront Theatre
Technical Specifications
Audio:
Mixing console
Amps
Speakers
Playback
Microphones
Clearcom
Program sound
Snake
Drapery:
Black Backing
Legs
Allen & Heath GLD 80 Digital Mixer w/AR2412
2 – PLX3202, 1 – PLX1602, 1 –RMX 1450
2 – QSC RMX 850
3 – SX 300 - movable, hung as SL, C, SR Mains
3 – SX80 hung on FOH catwalk as rear fill (SL,C,SR)
2 – SX 300 - hung as side stage monitors
3 – SX300, 4 SX80, extra
2 - Tascam CD-O1U CD player with auto-pause and auto-ready
7 SM58 vocal microphones with tripod boom stands
4 SM57 with tripod boom stands
2 wireless SM58
5 headsets, 5 belt packs
green room and dressing rooms
100’ Cat5e to AR2412 Box on SL, 24 XLR Inputs/12 XLR outs
Borders
Cyc (white)
2 - 22’L x 18’H (US crossover)
8 - 22’H x 8’W
1 - 18’H x 8’W (prosc., SL)
1 - 18’H x 4’W (prosc. , SR.)
1 - 39’L x 4’H
20’H x 40’L
LX Extras:
LX Boom stands
LX Floor stands
Sandbags
Gobo holders
Iris
Gel
Barn doors
2 - 8’H, and 6 side arms
10 shin busters
10 sandbags
4 A, 8 B (S4)
16 drop in S4 Iris kits
Some stock of cut Rosco
6 old style, 6 new
Projector:
Projector
Projection Surface
NEC NP-550W Projector w/standard Lens
attached with a Peerless Universal ceiling Mount
w/6ft post and clamp
Cyc(white) 20’H x 40’L at rear of stage
Booth
Storage
Tools
SL side of auditorium, small, some obstructed views
VERY limited storage in building
very limited selection of small tools
Miscellaneous:
-’House Paint’ -all black paint must be ICI Home Depot Black
Extras:
Wireless Internet
Telus ADSL 802.11.N
CLIENT USE ONLY
‘Technical Staffing Guidelines’ governs the use of the technical staff at WFT
WFT house lighting plot is available on the website in CAD / PDF format
Ground Plans are also available on the website in CAD / PDF format
Download