West Bengal Housing Infrastructure Development Corporation Limited (A Govt. of West Bengal Undertaking) HIDCO BHABAN, Premises No.35-1111, Major Arterial Road, 3rd Rotary, New Town, Kolkata-700156 Telephone No. (033) 2324-6037 / 38, Fax: (033) 2324-3016 e-mail: info@wbhidco.in website: www.wbhidcoltd.com No-HIDCO/GM (E)-IV/93(P-II)/129/Dtd-13/06/2013. Corrigendum No.3 OF 2013-2014 OF GM (ENGG. )-IV, W.B HIDCO Sub - “Interior works including acoustic, stage crafting, audio electrical & HVAC system of auditorium (nearly 1000 capacity) in Vocational Training Institute in AA-IIB, New Town, Kolkata” Ref – e-NIT No.12 of 2013-2014 of G.M (E)-IV, WB HIDCO. In reference to above tender, one BOQ of items with specification is hereby uploaded for the intending bidders of the above work. The bidders are requested to place their offers according to these B.O.Q items, in their financial bid in e-tender. Moreover, the bidders have to place rate and amount in B.O.Q sheet which is being uploaded with this corrigendum and they have to submit it in a separate sealed envelop, to justify their rates in the financial offer, along with submission of Demand Draft for Tender fees and EMD. This sealed envelop containing BOQ items rate and amount will be opened along with financial offer of etender on 21.06.2013 at 3.00 P.M. If any discrepancy is noted in between financial offer and supporting BOQ rate and amount, then the total financial offer will be liable to cancellation. All other terms and conditions remain unchanged. General Manager (Engg)-IV WB HIDCO TECHNICAL SECTION SECTION - TECHNICAL SPECIFICATION T1 Standard Specification T2 Design Parameters, ODU & IDU specification T3 Basis of Design T4 Standard Specification of Thermal/Acoustic Insulation T5 Standard Specification of G.I. Duct Work T6 Equipment wise Technical Data to be furnished by the Tenderer LIST OF APPROVED MAKES Section T-1 STANDARD SPECIFICATION The followings terms have been used in the tender specifications. ISI Bureau of Indian Standards. ASHRAE American Society of Heating Refrigerating & Air-conditioning Engineers, USA. ISHRAE Indian Society of Heating Refrigerating & Air-conditioning Engineers. ASME American Society of Mechanical Engineers. ASA American Standard Association. B.S. British Standards. CMH Cubic Meter per Hour. BTU/Hr. British Thermal Unit per Hour. Kcal/Hr. Kilo Calories per Hour. HZ Hertz. H.P. Horse Power Kg/Cm2 Kilo Gram per Square Centimeter. SAG Supply Air Grills. SAD Supply Air Diffuser. SAF Supply Air Filters. FD Fire Damper. VCD Volume Control Damper. RAD Return Air Damper. FAD Fresh Air Damper. RH Relative Humidity. DB Dry Bulb Temperature. WB Wet Bulb Temperature. DP Drain Point. The codes, regulation as detailed below shall be followed in this contract :1. Safety code for air-conditioning (revised) amendment 1 1991) IS 659 : 1964 (reaffirmed 2. Safety code for mechanical Refrigeration 1991) IS 660 : 1963 (reaffirmed 3. Testing of refrigeration compressors IS 5111 : 1993 4. Air-Cooled heat exchangers (amendment 1) IS 10470 : 1983 (reaffirmed 1991) 5. Metal Duct Work IS 655/SMACNA/DW – 142 6. Refrigeration As per ASHRAE / ISI / Air-conditioning & Refrigeration Air-conditioning institute Standards / ISHRAE SAFTEY CODES The following IS codes shall be followed: Safety code for mechanical refrigeration IS 660 Safety code for air conditioning IS 659 Safety code for scaffolds & ladders IS 3696 Part – I & II, 1966) Code of practice for fire precaution in Welding & cutting operations IS 3016 Code for safety procedures and practices In electrical works IS 5216 Safety code for constructions involving Use of hot bituminous material IS 5916 (1970) Safety requirements for wall openings, railings etc. Code of practice for safety and health Requirements in electrical & gas welding And cutting operations. IS 4912 (1978) IS 3696 (1966) Section– T-2 DESIGN PARAMETERS, ODU & IDU specifications T2.00 Given below are some design parameters which should be followed in addition to those given in various sections of technical specifications enclosed. T2.01 DC INVERTER SCROLL UNIT a) Temperature of air to inlet of condenser ºC : b) Refrigerant : 48ºC max. R-410a SPECIFICATION OF VARIABLE REFRIGERANT FLOW SYSTEM 1.0 The specifications under this section covers the supply, installation, testing and commissioning of the VARIABLE REFRIGERANT FLOW SYSTEM conforming to these specifications and in accordance with the requirements of the Schedule of Equipment and detailed Bill of Quantities. 1.1 General: Each VRF Unit shall consist of air cooled outdoor unit, multi-split system air conditioner indoor unit, each having capability to cool for the requirements of the individual area to be air-conditioned. The VRF unit should be capable of connecting different type indoors and Air Handling Units to one refrigerant circuit and control individually. Each VRF unit shall have minimum two number scroll compressors and in each module there shall be at least one DC inverter scroll Compressor (With controller) and capable of changing the rotating speed to follow variations in cooling loads. Each indoor units shall have the capability to cool for the requirement of the rooms. Compressor installed in each module unit shall be equipped with at least one DC Inverter Scroll Compressor. The system shall be capable of changing the rotating speed of Inverter compressor by Inverter controller to follow variations in cooling and heating load. The vendor should supply imported factory assembled, wired and tested outdoor unit instead of being shipped in modular section and later being sub-assembled at site. The Outdoor units shall be suitable for mix-match connection of all type of Indoor units. The Unit shall be capable of extending refrigerant piping up to maximum 200m in length with 110 mtrs. height difference between outdoor and indoor units. The compressors shall be OEM make. The minimum COP at full load shall be 3.73 . The unit shall be suitable for non CFC GREEN refrigerant R-410A. 1.2 OUTDOOR UNIT: The outdoor unit shall be imported factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired, tested with all necessary controls tested prior to dispatch conforming to the following specifications. a) All outdoor units module shall consist of minimum two scroll compressors for each Machine with one Inverter drive compressor capable to operate even when one compressor is unserviceable. b) The outdoor unit shall be such in design that it facilitates installation one after another close to each other. Preference would be given to compact units having smaller foot print. c) Outdoor units should be rugged of anti-corrosion design and should have strong base plate for easy mounting of unit. d) The outdoor unit shall comprise of sub cooling feature to effectively use the entire coil surface through proper circuit/bridge in order to prevent flushing of refrigerant owing to large length of piping. f) The condensing unit shall be provided with microprocessor based control panel. g) The outdoor unit shall be provided with Aero spiral design fan exhibiting low noise level characteristics complete with aero fitting grille to facilitate spiral discharge of airflow to effect reduction in pressure losses. The fan should be capable to respond to external static pressure of 5mm. h) The outdoor unit shall be factory gas charged with refrigerant R-410A . high efficiency i) Motor shall be speed controlled to ensure a stable operation for varying ambient; by a factory fitted direct acting head pressure activated variable speed drive to give precise discharge pressure and minimum power consumption of condenser fan motor. j) The condenser shall be complete with provisions for refrigerant piping connections, shut off valves and any other standard accessories necessary with the equipment supplied. The condensing unit shall be designed to facilitate fail safe operation when connected to multiple indoor units. 1.3 Scroll Compressor: The scroll compressor shall be an industrial quality rugged, cast iron, direct hermetic compressor with scroll plates, suction & discharge service valves. The compressor shall be completely enclosed in a chamber with no leakage path and providing the capability for scroll plates to separate. The compressor shall be provided with industrial solid motor mounts internal motor protection and vibration isolation pads. Each compressor shall be independently wired and piped to its own circuit for efficient operation & ease of maintenance. The compressor speed shall not exceed 3000 RPM. The compressor shall be highly efficient DC inverter scroll type. One of the compressors should be of Inverter control. The inverter compressor shall change the speed in accordance to the variation in cooling or heating load requirement through signals analyzed through the micro processor of the Unit.: a) All outdoor units shall have to operate through inverter drive to give accurate cooling with minimum required power meet load fluctuation and indoor unit individual control. All parts of compressor shall be sufficiently lubricated stock. Forced lubrication may also be employed. b) Oil heater shall be provided in the compressor casing. c) The Inverter compressor shall be efficient & reliable & shall be OEM make. 1.4 HEAT EXCHANGER: The heat exchanger shall be constructed with copper tubes mechanically bonded to aluminum fins to form a cross fin coil. a) The aluminum fins shall be covered by anti-corrosion resin film. b) The unit should have optimized path of heat exchanger for better efficiency of condenser. c) The unit shall be provided with necessary number of direct driven low noise level propeller type fans arranged for vertical discharge. Each fan shall have a safety guard. 1.5 REFRIGERANT CIRCUIT: The refrigerant circuit shall include liquid & gas shut-off valves and a solenoid valves at condenser end. The equipment must have inbuilt refrigerant stabilization control for proper refrigerant distribution. 1.6 SAFETY DEVICES: All necessary safety devices shall be provided to ensure safe operation of the system. Following safety devices shall be integral part of the out door unit : a) High pressure switch b) Fan drive overload protection switch c) Fusible plug d) Overload relay including overload protection for inverter driven compressor. Oil Recovery System Unit shall be equipped an oil recovery system to ensure stable operation with long refrigeration piping lengths. The system must be provided with oil balancing circuit to avoid poor lubrication in any unit. T2.02 INDOOR UNITS Air Handling UNITS: The units shall be floor mounted double skin type suitable for VRF DX system having multiple circuit with electronic expansion valve. GI outer casing should be with 0.6mm thickness with 25mm CFC free PUF insulation of density 40KG/cum complete with blower section suitable for static pressure as mentioned in bill of quantity. Unit shall have an attractive external casing for supply and return air. a) Maximum Face velocity across cooling coil MPM : 152.0 b) Maximum face velocity across pre-filters MPM : 152.0 Section T-3 BASIS OF DESIGN T3.00 Outside design conditions Summer / Monsoon / Winter T3.01 Inside design conditions Auditorium area Cleanliness T3.02 DBT °C 37.8/32.2/13.3 WBT °C 28.3/30.0/8.9 DBT °C 24 ± 1.5 Deg. C - RH 60±5% Filtration level 90% down to 10 micron. Occupancy 666 for 7206 sqft Fresh Air As per ASHRAE 62.1 2007 Illumination 1.1 Watt/sq. ft. Exposed roof considered as thermally insulated by means of TF quality thermocole or equivalent thermal insulating material from inside for the airconditioned area. POWER SUPPLY: Stabilised three phase four wire AC supply i.e. 415 Volts ± 10 % & 50 Hz ± 5 % with double earthing shall be made available in the outdoors & in each AHU panel by the client through their own agencies. T3.03 EXPOSED ROOF / CEILING: All exposed roof / Ceiling shall be insulated with 50mm thick TF quality thermocole. T3.04 ASSOCIATED CIVIL / ELECTRICAL AND OTHER WORKS TO BE PROVIDED TO THE AC CONTRACTOR BY THE CLIENT (THROUGH THEIR OWN AGENCIES) a) Structural platform, if any, for installation of outdoor units . b) Stabilised three phase four wire AC supply i.e. 415 Volts ± 10% & 50 Hz ± 5% with double earthing and termination shall be made available near the outdoor units . Any kind of false ceiling work, return air boxing, wooden /aluminium frames for fixing grills / diffuser/duct work etc. for the respective premises. c) d) Power for erection, testing and commissioning of the plant. e) Any kind of masonry shafts for laying pipes / cables / ducts etc. T3.05 SYSTEM DESCRIPTION & FEATURE Inverter Type VRF System The system shall be intelligent and energy efficient too. The system will typically consist of an outdoor unit using an inverter controlled variable speed compressor connected to serially arranged refrigerant pipe or with number of indoor units. The scope of present tender shall be: - Provision Provision Provision Provision of of of of Floor Standing Air Handling unit ductwork inside the conditioned area. duct insulation grills, diffusers, duct dampers, fire dampers etc. For inverter controlled machine the outdoor unit shall be controlled through inverter which controls the frequency of controller motor to match the auditorium A.C. load. The unit shall be provided with highly sophisticated electronic control for efficient zone control. This ensures optimal airconditioning of individual space and thereby minimizes the power consumption. The simplicity of variable of VRV system results in easier installation and system functions under high ambient condition. The suction line shall be insulated with polyethelene /nitrile rubber based insulation. Depending on load, IDU and ODU shall operate. Suitable drain shall be connected to the IDU to remove condensate. The compressor controlled through inverter or engagement/dis-engagement of fixed and rotating scroll will modulate the refrigerant flow to meet the varying cooling loads. The unit shall be capable of operating in stepless control mode. The unit shall be provided with all necessary controls as well as accessories. Tenderer shall quote any of the above alternatives. However, technical details including power consumption shall be furnished by the tenderer clearly. Section T-4 STANDARD SPECIFICATION OF THERMAL / ACOUSTIC INSULATION T4.01 INSULATION OF PIPES T4.02 a) The pipe to be insulated should be cleaned thoroughly with steel brush for removing dirt, rust and grease. b) Fix insulation of specified thickness tightly and seal all joints with adhesive compound. THERMAL INSULATION OF DUCT MaterialCross linked closed cell preformed polyethelene/closed cell nitrile based preformed section . Thickness- section of Min. 9 mm for closed cell polyethelene having K valve 0.027-0.029 and minimum density 32 kg/m3/12 mm thk. for nitrile rubber base insulating material. The material shall be fire retardant type with Class-I fire rating. The material shall have self-extinguishing and non-dripping quality and CFC free. T04.03 UNDER DECK INSULATION Material- 50mm thick TF quality Thermocole. The material shall be fire retardant type with self-extinguishing and non-dripping characteristics. Section-T5 STANDARD SPECIFICATION OF G.I. DUCT WORK T5.00 SCOPE The scope of work covers supply and installation of i) ii) iii) iv) Sheet metal ducting. Air intake and exhaust louvers. Grills and Diffusers. Volume control dampers. T5.01 For Grills & diffusers, tenderer shall submit catalogues since the units are standard. T5.02 MATERIAL T5.02.01 The material for various applications of air ducting shall be as follows : Application Material Ducting for Air-conditioning G I sheets continuous galvanized with minimum zinc coating 180 g/sq. m both side inclusive as per IS:277 – 1977. T5.02.02 All galvanized plain sheets shall be free from wrinkle. The zinc shall be clean, even and free from galvanized spots. Material shall be of approved make. T5.03 All ducts for air-conditioning shall be rectangular in cross section and shall be fabricated as per ISI/SMACNA. T5.04 Standard elbows with a R/D ratio not less than 1.25 shall be used as far as possible. Where space restrictions do not permit use of standard radius, elbow with lesser R/D ratio and square elbow with equally spaced double thickness vanes may be used. T5.05 GRILLS/DIFFUSERS Supply air grills shall be double deflection type with the horizontal face bars and vertical rear bars placed in a rigid marginal frame. All grills shall be provided with integral opposed blade, grill face key operated dampers. Return air grilles shall have fixed face bars. Bars shall be set at 40 deflection of vision-proof installation the grilles shall be complete with rigid marginal frames and shall be matching with supply grilles. Diffusers shall be round/rectangular face with horizontal air diffusion pattern. All diffusers shall be provided with face operated volume control dampers. Section T-6 EQUIPMENTWISE TECHNICAL DATA TO BE FURNISHED BY THE TENDERER T6.00 SCOPE Tenderer shall furnish the equipmentwise technical data as per the following : A) OUTDOOR UNITS a) Make – b) Model – c) Compressor type – d) No. of compressors – e) Refrigerant – f) Capacity at the specified condition – g) Air discharge h) Electrical power supply i) Input power at full load j) Input power at part load k) EER l) Net weight m) Condenser air quantity n) No. of fans per condenser o) Overall dimension p) Controls provided B) Floor Standing Air handling Units a) b) c) d) e) f) g) h) Make Model Capacity Air flow Power supply Dimension Net weight Power consumption LIST OF APPROVED MAKES S.N Description Makes 1 2 VRF system Air Handling Units DAIKIN/TOSHIBA/MITSUBISHI/VOLTAS Edgetech/Zeco/Airflow 3 GI Sheet Sail/Nippon/Tata/Jyoti 4 Grilles/Diffusers Caryaire/Air master/ Premier/MR Sheet 5 Thermal Insulation Armacell/K Flex/ UP Twiga/Beardsell 6 Copper Pipe Mandev/Nippon/Rajco/Mehta TECHNICAL SECTION Section T-1 STANDARD SPECIFICATION The followings terms have been used in the tender specifications, drawings etc. HZ Hertz. H.P. Horse Power Codes to be followed: 1. PVC insulated ( HD) Electric Cables for working voltage up Including 1100 Volts. IS : 1554 ( Part I) 2. HRC Cartridge fuse links upto 650 Volts. IS 2208 : 1976 3. Starter IS 8554 ( Part I) 1979 4. Three phase induction motors IS : 325 5. PVC insulated ( heavy duty ) cables for working voltage up to 1.1. KV and up to 11 KV Grade respectively. IS 1554 : 1981 Part I & 6. Code of practice for electrical wiring installations. IS 732 : 1989 7. Code of practice for earthing IS 3043 : 1966 8. Circuit breaker A.C IS 2516 : 1980 Part I & II 9. Contactors for A.C for voltage upto 1100 V. IS 2959 : 1975 10. Low voltage switch gear and control IS 8623 : 1993 Part I 11. Specification for cables glands IS 4821 12. Code for selection, installation & maintenance of switch gear and control gear. IS 10118 : 1982 Part I to IV SAFTEY CODES Code for safety procedures and practices In electrical works IS 5216 Section-T2 T2.01 ASSOCIATED CIVIL / ELECTRICAL AND OTHER WORKS TO BE PROVIDED TO THE AC CONTRACTOR BY THE CLIENT (THROUGH THEIR OWN AGENCIES) a) Stabilised three phase four wire AC supply i.e. 415 Volts ± 10% & 50 Hz ± 5% with double earthing and termination shall be made available near the outdoor unit of each floor in a D/B. Outlet feeder from the D/B to the micro-processor panel/unit of the outdoor unit shall be carried out by the successful contractor. b) Power for erection, testing and commissioning of the plant. SectionT-3 STANDARD SPECIFICATIONS OF ELECTRICAL DISTRIBUTION BOX AND CABLES T3-01 MOTOR CONTROL CENTRE CONSTRUCTIONAL FEATURE Single front non-draw out design, free standing/wall mounted, compartmentalized type. Panel with sheet steel (CRCA), i.e. 1.6 mm thick. except front door. The same may be 2 mm thk. sheet steel. Dust and vermin proof design. The degree of Protection Class for enclosure shall be minimum IP-55 with 35 KA fault level. Safety insulating barriers shall be provided in each module to prevent accidental contact with live parts. Cutouts in the modular door shall have neoprene gaskets ensuring to prevent dust ingress. Neoprene gaskets shall be used for cable alley door fixing. All terminations shall be shrouded in an approved manner. The entire enclosure shall meet with IS:2147/1962. Feeder connections shall be made out of solid insulated copper/aluminium wires or strips with bimetallic clamps wherever required. Internal wiring, bus bar markings etc. shall conform to IS:375/1963. Internal wiring shall have terminal ferrules. Main switch should be at an easily accessible height and the highest switch operating handle should not be over 1.75m from floor level. Cable glands need not form part of the switch board as the cost of glands will form part of the cable termination. Incomers shall be three phase and neutral and of copper or aluminium or aluminium alloy and rated for a temperature rise of 30C over the ambient temperature specified, based on insulated conductor rating (IS:8084-1976). Isolators shall be fixed on wall on self-supported angle iron frame work as required and mounted as near to the motor as possible. Where several motors are installed, isolators if required shall be provided at a central location on a common frame work. All panels shall be meggar-tested and shall not be commissioned till the values are more than 2.5 megohms phase to phase and 1.5 megohms phase to neutral. All meters on the panel shall be calibrated before commissioning. The general arrangement and fabrications drawings shall be got approved before taking up for fabrication. T3-02 CABLES All cabling work from MCC/Distribution Board to various drives as well as to various local control centers shall be carried out by the successful tenderer. LT power cables within the enclosed premises shall be PVC insulated, unarmoured PVC sheathed Copper conforming to IS:1554-1988. Cables, running indoors shall be laid on walls, ceiling, inside shafts or trenches. Single cables laid shall be fixed directly to walls or ceiling and supported at not more than 500 mm. Where number of cables are run, necessary perforated cable trays shall be provided. Perforated cable trays shall be mild steel or Aluminium as specified in the schedule of work. SR. NO. A PROPOSED SCOPE OF WORKS & BUDGETARY ESTIMATE FOR VTI AUDITORIUM AT NEW TOWN, KOLKATA ITEM NAME TECHNICAL SPECIFICATION UNIT QTY. Sqm. 8600 INTERIORS & ACOUSTIC TREATMENT 1 PEST CONTROL & ANTI-TERMITE TREATMENT (at all areas) Providing Pest control and Anti-termite treatment by appointing a specialised agency as per the specifications mentioned by the Bureau of Indian Standards and Agencies specifications (whichever is higher) for general civil, timber / carpentry works, gypsum related work, including a 5-year guarantee under suitable undertaking on stamp paper etc., complete as directed. (Mode of measurement to be on carpet-area of floor and not the area of surface treated) 2 DISMANTLING (as provisional item) Dismantling of brick masonary & plaster works and carting away of debris from site as required & directed by EIC. Sqm. 10 FULL BRICKWORK (for stage structure) Brick work 250mm thick, with F.P.S. bricks of class designation 75 in superstructure above plinth in all shapes and sized in cement mortar 1:6 (1 cement : 6 medium course sand) all complete including the cost of scaffolding and curing as directed by EIC. Cum. 2 4 HALF BRICKWORK (as provisional item) Brick work 125mm thick, with F.P.S. bricks of class designation 75 in superstructure above plinth in all shapes and sized in cement mortar 1:4 (1 cement : 4 medium course sand). Cost to include lintels above doors etc. all complete including the cost of scaffolding and curing as directed by EIC. Sqm. 20 5 CEMENT PLASTER (as provisional item) Applying cement plaster upto 15mm thick in 1:6 cement sand mortar as directed by EIC. Sqm. 50 PLASTER OF PARIS (as provisional item) Providing & applying punning upto 6mm thick (avg.) layer of super fine Plaster of Paris applied over selected existing and new plastered surface on walls and columns finished smooth, inclusive of surface preparation as directed and instructed by EIC. The finished surface shall be smooth and in perfect level so as to avoid unevenness and ready to take on paint. Sqm. 50 CARPET FLOORING AT HALL AREA Providing & laying of broadloom roll carpet of 22 oz., 100% eco solution premium branded nylon, solution dyed, pattern loop of approved shade, all complete. Sqm. 785 WOODEN FLOORING AT STAGE Providing & laying HDF plank (1200 x 200mm) flooring, Class 33 Heavy Commercials AC-5 grade as per manufacturer's specification of approved shade including 2mm foam beneath for stage & adjacent steps and all accessories complete. Sqm. 145 PLYWOOD PANELING WITH GLASSWOOL IN-FILL Providing & fixing plywood paneling with 12mm thick commercial plywood fixed on plywood framework of section 19 x 50mm including all hardwares. The inside of the structure will be filled with 50mm thick glasswool of 48Kg / cum all as per direction of EIC. Sqm. 800 Sqm. 260 Sqm. 300 Sqm. 100 3 6 7 8 9 10 11 12 Providing & fixing of acoustic fabric paneling as per manufacturer's specification. The panel comprise of 12mm thick recron acoustical ACOUSTIC FABRIC PANELING WITH RECRON IN-FILL over plywood board. The top will be covered with fire rated fabric of approved paneling shade with PVC edge gripper, all complete as per design, drawing & direction of EIC. Rate does not include the cost of base plywood paneling. Providing & fixing of jute mat paneling as per manufacturer's specification. The panel comprise of 12mm thick recron acoustical board. The top will be covered with jute mat of approved shade JUTE MAT PANELING WITH RECRON IN-FILL over plywood paneling with PVC edge gripper, all complete as per design, drawing & direction of EIC. Rate does not include the cost of base plywood paneling. Providing & pasting of 6mm thick approved HDF decorative embossed panel finished with lustre paint / melamine polish as per DECORATIVE PANELING over plywood paneling design, drawing & direction of EIC. Rate does not include the cost of base plywood paneling. RATE AMOUNT 13 14 15 16 17 18 19 20 21 VENEER PANELING over plywood paneling Providing & pasting of 4mm thick approved veneer finished with PU matt polish as per design, drawing & direction of EIC. Rate does not include the cost of base plywood paneling. Sqm. 140 SKIRTING Providing & fixing 150mm high 12mm thick commercial plywood with 4mm thick approved veneer pasting finished with melamine polish as directed by EIC. Base rate of veneer - Rs. 1000/- Per Sqm. Rmt. 200 ACOUSTIC GYPSUM FALSE CEILING Providing & fixing acoustic gypsum ceiling with designed profile on ceiling board as per manufacturer's specifications. Rate to include all fastening accessories with approved finishes. Ceiling boards shall be made of IGL make of size 1200mm x 2400mm of approved design. Board shall render a NRC level of 0.75 - 0.85. Suspension system shall be done with hanger bar, intermediate channel and ceiling section as per manufacturer's specification. Installation to comprise of main intermediate channels spaced at 1200mm centres securely fixed to the structural soffit by approved hangers at 1200mm maximum centres & not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. Rate to include all cutouts / filling for lights, AC grills & diffusers and other services as required at site. Sqm. 510 PLAIN GYPSUM FALSE CEILING Providing & fixing of false ceiling with 12.5mm thick plain gypsum board as per India Gypsum / manufacturer's specification, all complete and ready to apply paint as per design, drawing & direction of EIC. Rate to include all cut-outs / filling for lights, AC grills & diffusers and other services as required at site. Sqm. 400 LAMINATED FALSE CEILING Providing & fixing of false ceiling with 12mm thick BWR plywood of approved make fixed on GI frameworks finished with 1mm thick approved laminate of approved make, all complete as per design, drawing & direction of EIC. Rate to include all cut-outs / filling for lights, AC grills & diffusers and other services as required at site. Sqm. 150 MS CATWALK OVER HALL & STAGE Supply, installation, erection and fabrication of catwalk with MS of desired sections over hall and stage area. The structure shall be as per approved design & direction of EIC. Rate includes painting of the structure with enamel paint of approved make and shade. Lot 1 MS LIGHT & SOUND PORCH Supply, installation, erection and fabrication of porch with MS of desired sections and necessary supports as per approved design & direction of EIC. 19mm thick commercial plywood to be fixed on the structure as platform. The verticals to be finished with 4mm thick approved veneer, all as per direction of EIC. Base rate of veneer - Rs. 1000/- Per Sqm. Lot 1 MS LADDER Supply, installation, erection and fabrication of ladder with MS of desired sections to make access to light & sound porch. The structure shall be as per approved design & direction of EIC. Rate includes painting of the structure with enamel paint of approved make and shade. Nos. 1 GENERAL PAINTING Acrylic emulsion paint with approved shade and colour of ICI Dulux / Asian Paints or equivalent with two coats of putty, two coats of primer and three coats of approved acrylic emulsion paint, including preparation of surface, scrapping, sand papering, scaffolding, all materials, labour etc. complete. Sqm. 1000 FLUSH DOOR Providing & fixing of double leaf door made with 38mm thick solid core flush door to avoid flanking noise, finished with 4mm thick approved veneer with melamine polish on both sides, including in position necessary fittings and hardwares like handles, hinges, door closers, locks etc. of approved make. Base rate of veneer - Rs. 1000/- Per Sqm. Nos. 9 23 GREEN ROOM LEDGE & MIRROR Providing & fixing plywood ledge (450mm depth) with 19mm thick commercial plywood fixed on plywood framework of section 19 x 50mm, including all hardwares and finished with 1mm thick approved laminate as directed by EIC including 4mm thick mirror with edge-polished on 9mm thick commercial plywood backing fixed with SS studs as per design & direction of EIC. Base rate of laminate - Rs. 350/- Per Sqm. Rmt. 20 24 SAFETY SIGNAGES Nos. 40 25 STAGE PODIUM Nos. 1 26 SALE COUNTER Providing & fixing of sale counter at lobby using stone top as per drawing & direction of EIC. Base rate of stone : Rs. 4000/- per sqm. Rmt. 22 FULL GLAZED PARTITION & DOOR (for VIP seating enclosure) Supply & installation of full height glass partition with 12 mm thick toughened clear glass resting on SS patch fittings of approved make all complete as per direction of the Architect & EIC. Sqm. 45 STAGE WOODEN UNDERSTRUCTURE Providing & fixing hardwood beam of section 100 x 150mm in both directions over brick pillars with top fixed with 40mm thick wooden plank as per design & direction of EIC. Sqm. 145 22 27 28 Total Amount Providing & fixing acrylic autoglow box signage as per approved design. Providing & fixing of podium as per design made of 19mm thick commercial plywood and 4mm thick veener of approved shade. The veneer to be melamine polised, all complete as per design & direction of Architect / EIC. B Sr. No. 1 2 3 4 5 6 7 8 9 10 STAGE CRAFTING Item Description GRID FABRICATION: 75mm x 75mm x 6mm MS Angle main runner (Lower Level) 75 OD MS pipe (Bottom Level) and cross section 32 OD Black Pipe with cover 19mm commercial ply and red oxide and black paint complete set (Catway). PROCINIUME GRID: 100 X 100 Square Box Medium Guage main runner cross section 50x50 square box with red Oxide and black paint complete. Providing, fitting and fixing of motorized Horizental operated main curtain mechanism with curtain controller unit complete with 1.5 HP 230 volt single/three phase Compton greaves or equivalent make A.C. motor, worn reduction gear, rigid coupling 25 mm dia Main Cartain cloath. Providing, fixing, testing and commissioning of double gathered main curtain in two part to be made with cotton velvet cloth of approved make, shade and colour, including backing cloth of approved make, decorative bridle with ball fringes, tassels etc. Back curtain (Manual) complete with black cotton cloth. Fril Bar : P & F manually operation Fril Bar up & Down system 100 mm dia bearing fitted pulley and MS Bracket 8mm Poly puppling rope 32 OD MS Black Pipe and black Cloth Complete set. Light Bar Wing System : P & F Light Bar mechanism consisting of 100 mm dia bearing fitted with pully with MS bracket 6 mm thick steel flexible wire adjustable stainer / rope clamp, 48 mm OD Black Pipe and 1000 Kg capacity manual winch with paint complete set. Wings Mechanism (Horizontal & Moveable) With 1inch OD pipe along with jute & Black Cloth. Cyclorama frame & cloth (Bombay Dying) With 48mm OD pipe –cross member 32 OD Pipe. Light Ladder Total Amount Unit Qty. Set 1 Set 1 Set 1 Set 1 Set 1 Set 5 Lot 4 Set 6 Set 1 Set 4 Rate Amount C Sr. No. 1 ELECTRICAL WORK Item Description Unit Qty. MAIN LV POWER DISTRIBUTION BOARD nos. 1 nos. 4 nos. 1 nos. 1 Supply, delivery, installation, testing & commissioning of Main LT Distribution Board with 400A Rated, Al. busbar (as per the relevant SLD Dwg. and as per our specification) The Main incomer and feeder details are furnished below : Incomer 1 - 400A TP+N, MCCB (35KA) with front door drive handle, door interlocking system 1 - lot indicating lamp & control fuses 1 - Voltmeter with Sel. Sw. 0 - 500V, 96 X 96, MI type 1 - Ammeter with Sel. Sw. 0 - 400A, 96 X 96, MI type 3 - C.T 400/5A, 10VA, Cl - 1.0 1 - C.T 400/5A, 10VA, Cl - 1.0 1 - Micro-processor based load manager suitable for 3ph, 4 wire, system, 5A C.T secondary Feeders MCCB TP+N with front door drive handle with door interlocking of following rating 3NOS - 160A 3NOS - 125A MCB Feeder 10 KA Curve - C 4 - 63A TPN MCB 2 2.1 MCB DB LIGHTING / POWER DB Supply, delivery, testing & commissioning of ready made MCB DB double door with TOP & BOTTOM ENTRY - with separate Neutral per phase, double door, suitable for IP - 41 protection with DB and feeder name plate engraved 2.2 Incomer 1 - 4P MCB ISOLATOR - 63A Feeder 9 - SP MCB - 10A, 10 KA 9 - SP MCB - 25A, 10 KA STAGE LIGHTING DB Supply, delivery, testing & commissioning of ready made VERTICAL MCB DB with TOP & BOTTOM ENTRY - with separate Neutral per phase, double door, suitable for IP - 41 protection with DB and feeder name plate engraved 2.3 Incomer 1 -TPN+N MCCB MCCB -125A Feeder 3 Nos - 32A TP MCB 3 Nos - 10A SP MCB SOUND SYSTEM DB Supply, delivery, testing & commissioning of ready made TPN 4WAY DOUBLE DOOR MCB DB with TOP & BOTTOM ENTRY with separate Neutral per phase double door, suitable for IP 41 protection with DB and feeder name plate engraved Incomer 1 - TPN MCB 63A, 10KA Ph. Feeder 3 - DP RCCB (30mA) - 40 A Sub-Feeder 12 - SP MCB 16A, 10 KA Rate Amount 3 3.1 EARTHING Supply & installation of Earth Pit as per IS : 3043 with GI plate (600 x 600 x 6 mm) electrode (placed at a depth of 3.0 Mtr), 2 nos. GI earth Flat of size 25 x 6mm shall be bolted with the plate & will be drawn upto ground level, one 3 Mtr long GI pipe. nos. 2 nos. 2 mtrs. 150 mtrs. 150 nos. 2 4.2 Supply, laying & interconnection by bolting / welding of the following size of GI Flat tape 50 X 6mm sq. horizontal run, along the parapet / wall by suitable insulated saddling. Welding / brazing part should be covered by bituminous paint after installation. mtrs. 250 4.3 Maintenance free Earth Pit made of ground enhancing material (GEM) of required qty 6 Bags of II.3Kg/bag and copper bonded earth rods (3 nos) of size 5/8" dia x 4' length and 3 no. of earthrod clamp & 15 Mtr 50 X 0.5mm soft Copper strip. nos. 2 mtrs. 250 nos. 2 nos. 2 mtrs. mtrs. 4000 500 mtrs. 500 mtrs. 500 mtrs. 1500 mtrs. 1500 mtrs. mtrs. mtrs. 6000 150 150 mtrs. 200 3.2 3.3 3.4 4 4.1 4.4 4.5 4.6 5 Maintenance free Earth Pit made of ground enhancing material (GEM) of required qty 3 Bags of II.3Kg/bag and copper bonded earth rods (3 nos) of size 5/8" dia x 10' length and 1 no. of earthrod clamp. 25 x 6mm GI Flat for riser / along cable tray for earth station at each 25 x 3mm Copper Flat for UPS earthing LIGHTNING PROTECTION Supply, delivery and installation of GI pipe electrode Earth Pit as per IS : 3043, class B, 50mm dia, 3 Mtr long GI pipe with 10mm dia hole around the surface of the pipe shall be used. Necessary accessories like watering, flunnel with wire mesh, etc. Supply, laying & interconnection by welding / bolting of the 25 X 3mm size of Al. Flat horizontal & vertical run along the building wall from top to the ground level Earth Pit by suitable insulated saddle. Supply & installation of 5 PRONG Lighting Conductor to be fixed on the strategic points at roof top wall as per the instruction by EIC. Supply & installation of Earth Test link with 300mm length Al. Flat of 40 x 6mm size to be fixed on porcelain insulator support on wall. INTERNAL WIRING FOR POWER / LIGHT POINTS NOTE : Wiring for lighting, exhaust fan, power points etc. shall have to be done by rigid PVC conduit on exposed part or with rigid PVC conduit wherever recessed in wall / plastered surface whenever concealed along the wall. Necessary PVC JB / Circular box / Inspection JB have to be provided. CIRCUIT MAINS / SUB-MAINS WIRING AND DIRECT LIGHTING Circuit Mains shall be drawn through PVC conduit from LDB to the switch board or between switch board by loop in - loop out method. Supply & laying of following sizes of rigid PVC conduit on surface / recessed manner with chase cutting, mending good of the surface / wall / tray including fixing of Circular / Square JB, Inspection JB, clamp, socket, fish wires, etc. 5.1 5.2 5.3 5.4 5.5 i) ii) iii) iv) v) 5.6 i) 25mm dia PVC conduit ii) 32mm dia PVC conduit Supply & laying of PVC flexible conduit (For final length of connection, if any) 20mm dia PVC flexible conduit Supply & drawing of following sizes of PVC insulated FRLS stranded copper conductor wires, 1100V grade in existing PVC conduit / or laying / wiring upto power plug point (6A, 6/16A, or AC point) 2 x 4.0 sq.mm Cu + 1 x 1.5 sq.mm Cu wire (for AC) 2 x 2.5 sq.mm Cu + 1 x 1.5 sq.mm Cu wire (for sub-main wiring) 3 x 1.5 sq.mm Cu wire 4C x 25 sq.mm Cu flexible cable (For AC) 4C X 16 sq.mm Cu flexible cable (for AC) 300mm GI Cable Tray with hanging support and all required accessories 6 POINT WIRING (CONTROLLED FROM SWITCH BOARD) Point Wiring shall be started from the respective modular switch of the switch board upto the first point of light / fan / power point. 20/25mm dia through pre-laid MS/PVC conduit shall be used in recessed manner along the wall. Cost of modular switch, switch board, tressaplate etc. are not included in the price. Light points by suitable conduit and 3 x 1.5 sq.mm Cu wire 6.1 (upto 5 Mtr) Exhaust Fan / Raw power points (6/10 Amps) by suitable conduit and 3 x 1.5 sq.mm Cu wire along with supply of switch 6.2 modular type. Control & ON / OFF function shall be done by switch. 6.3 Modular Switch & Socket 6/10 Amps switch 16 Amps switch 6 Amps socket 16 Amps socket 6.4 Modular Tressaplate with M.S Box 1 Mod 2 Mod 3 Mod 4 Mod 6 Mod 8 Mod 12 Mod Wiring for power socket point 6A or 6/16A socket etc. shall NOTE : be paid as per the Meter run of conduit & wiring. 7 7.1 a) b) 7.2 7.3 25mm PVC conduit heavy gauge 32mm PVC conduit heavy gauge Supply and laying of CAT-6 Data Cable Supply and laying of 2 pair Telephone Cable 8.1 8.2 8.3 a) b) 90 points 40 nos. nos. nos. nos. 50 15 20 15 nos. nos. nos. nos. nos. nos. nos. 10 15 25 4 6 10 6 mtrs. mtrs. mtrs. mtrs. 250 150 305 200 mtrs. mtrs. 150 250 nos. nos. 8 12 TELEPHONE / NETWORKING Supply and laying Raceways / Conduits on existing flooring / wall. The Raceways / Conduits shall be fixed to the flooring with clamps for finished levels as per site conditions or through partitions with all accessories, bends, pull wire etc. 8 points CABLE & CABLE TERMINATION Supply, laying, dressing, testing & commisssioning of the following sizes of 1.1 KV grade XLPE, armoured cable of Al / Copper conductor, with GI strip / wire armour to be laid along prepared trench / pre-laid cable tray with proper clamping / saddle. 3.5C x 70 sq.mm Al wire 4C x 25 sq.mm Al wire End termination for 1.1 KV grade cables with single compression type cable gland and heavy duty Al / tinned copper cable sockets. Rate shall be inclusive of all sundry materials like adhesive, tapes etc. including plugging unused holes, saddle etc. 3.5C x 70 sq.mm Al wire 4C x 25 sq.mm Al wire Total Amount Sr. No. GENERAL ILLUMINATION Item Description Unit Qty. Supply & installation of Light Fittings 1 2 x 26W Recessed Down Lighter with Atco Dimmable Ballast with 2 nos. 26W DE lamp 4 pin … For seating area Nos. 160 2 LED Strip in 7.2 per mtr. with 30 LEDs with driver Rmt. 200 3 12V/50W White Halogen Fitting with Osram Electronic Transformer and 12V/50W Halogen lamp … For special focus Nos. 15 4 Wall-mounted luminaire as mirror light … For green room Nos. 15 Nos. 90 Nos. 1 5 6 2 x 18W Surface-mounted Down Lighter with Electronic Ballast with 2 nos. 18W lamp … For ancilliary areas Dimmer with Rack Total Amount Rate Amount D Sr. No. STAGE LIGHTING Item Description Unit Qty. 1 Supply & installation of Light Fittings 1KW Fresnel Spots with bi-post halogen lamp Nos. 8 2 1KW acting area Flood Light with 4-leaf burn door, with lamp Nos. 8 3 1KW Par 64 with 1KW lamp CP-60 500W Cyclorama Flood Light with halogen lamp & color holder 18 Channel Mixture Power pack consisting of 6 Channel Electronic Dimmer with 3phase incoming supply & 4KW per channel DMX with interconnections Color Gel 2 x 36W Surface type CFL fitting with 2 nos. 36W CFL lamp (General Light for Stage) 32 x 2 Channel Patch Panel with 32 MCB, plug tops, sockets indicators, complete with interconnections Smoke Diffuser Accessories G-Clamp for fixing the Luminaries Dimmer Rack for mounting 2 Electronic Dimmers 1.5 sq.mm 2 core PVC insulated copper cable 1 X 10 sq.mm cable 1 X 6 sq.mm cable Total Amount Nos. 20 Nos. 8 Nos. 1 Nos. 2 Nos. 40 Nos. 16 Nos. 1 Nos. 1 Nos. Nos. Coil Coil Coil 50 1 18 1 1 4 5 6 7 8 9 10 1 2 3 4 5 Rate Amount E Sr. No. 1 2 3 4 5 6 7 8 9 10 11 FIRE DETECTION & ALARM SYSTEM Item Description Supply & installation of 1 loop Addressable Main Fire Alarm Panel Supply & installation of Addressable Smoke Detector with Base for BFC Supply & installation of Addressable Smoke Detector with Base for AFC Supply & installation of Addressable Multi Sensor (Photo & Heat) Detector with Base for BFC Supply & installation of Beam Detector with Base Supply & installation of Addressable Manual Call Point with Base Supply & installation of Addressable Wall-mount Sounder with Strobe with Base Supply & installation of Response Indicator Supply & installation of Control Module Supply & installation of Fault Isolation module Supply & laying of Fire resistant Armoured Cable 2C 1.5 sq.mm. Total Amount Page 10 Unit Qty. Nos. 1 Nos. 15 Nos. 15 Nos. 5 Nos. 7 Nos. 10 Nos. 10 Nos. Nos. Nos. 15 8 3 Rmt. 2000 Rate Amount F Sr. No. 1 2 3 SPRINKLER BRANCHING SYSTEM Item Description Supply & installation of Main & Sub Branching of Pipe Dropping pipe and all necessary fitting items, length of drop considered as 1200mm. Pendant / Wall type Sprinkler including rosset plate, as required. Total Amount Unit Qty. Lot 1 Nos. 80 Nos. 40 Rate Amount G Sr. No. 1 2 3 4 FIRE EXTINGUISHER Item Description MAP 90 Net Weight 2 Kg MAP 90 Net Weight 6 Kg CO2 4.5 Kg HCFC 123 Clean Agent 4 Kg Total Amount Unit Qty. Nos. 5 Nos. 13 Nos. Nos. 1 1 Rate Amount H Sr. No. SOUND & AUDIO-VISUAL SYSTEM Item Description A3 DISPLAY SYSTEM Projector Screen - 278'' diagonal High Gain motorized screen with 16:10 aspect ratio 6000 Lumens WXGA (16:10 aspect ratio) DLP Projector with long throw Lens Ceiling-mount Manual Kit for Projector A4 50" diagonal or higher Proffessional LED Display A5 A6 A7 A8 A9 Ceiling Mount Kit for LED Display 1:6 VGA Distrbution Amp 1:5 Video Distribution Amplifier VGA Transmeter & Receiver Floor Box on stage A1 A2 Make Qty. DRAPER / DALITE 1 PANASONIC / SONY 1 1 SAMSUNG / PANASONIC 4 Custom EXTRON / KRAMER EXTRON / KRAMER EXTRON / KRAMER Custom 4 1 1 7 2 VIDEO SYSTEM B1 DVD Player with USB Input B2 B3 18X Optical Zoom, CCD PTZ Camera Visualiser (Document Camera) PIONEER / SAMSUNG / SONY VADDIO / SONY SAMSUNG / ELMO 1 1 1 AUDIO SYSTEM MIPRO / BOSCH / AKG/ SHURE MIPRO / BOSCH / AKG/ SHURE MIPRO / BOSCH / AKG/ SHURE MIPRO / BOSCH / AKG/ SHURE C1 Directional Wireless Handheld Microphone C2 Directional Wireless Collar / Lapel Microphone// SHURE C3 Gooseneck Microphone for Podium C4 Handheld (VOCAL & INSTRUMENTAL) Wired Microphone C5 LINE ARRAY / FOH Speaker – Active, modular beam steering system, 130 - 20 KHz, beam control limit 400 Hz. C6 1000 Watt power Amplifier for driving 800 Watt Speakers C7 280 Watt 15" portable powered Speaker System, bi ‐amplified, 220 Watt low frequency, 60 Watt high frequency, 15" low‐frequency transducer, 1" (exit) neodymium compression driver C8 Speaker Management System C9 24 Channel Mixer WITH EFFECTS C10 18" Self Powered Suwoofer with inbuilt 600W amplifier C11 12" Self Powered Stage Monitor Speakers with dual 500Watt inbuilt amplifier C12 200 Watt Green Room Speakers C13 Power Amplifier for Green room D1 D2 INSTALLATION EQUIPMENT, ACCESSORIES & CABLES 27U Closed Rack VALRACK / RITTAL Cable & Connector EXTRON / KRAMER LS LS D3 ACCESSORIES & CABLES LS E1 INSTALLATION & CERTIFICATION Installation, Designing & Programming E2 Training, Project Documentation & Project Management Total Amount 2 2 1 8 JBL / BOSCH/QSC/ TANOY 2 CROWN / QSC / LABGRUPPEN/BOSE 1 JBL / BOSCH / QSC/TANOY 4 DBX / BSS SOUND CRAFT / YAMAHA/ BEHRINGER JBL / BOSCH/QSC/ TANOY JBL / BOSCH/QSC/ TANOY JBL / BOSCH/QSC/ TANOY CROWN / LABGRUPPEN/ QSC/BOSE As per approved make 1 1 2 2 1 1 Rate Amount I Sr. No. 1 2 3 4 AUDITORIUM CHAIRS Item Description Supply & installation of JUPITER Chair with Desklet of Godrej make for auditorium general seating OR Equivalent from HAWORTH / HERMAN MILLER / FIGUERAS GLAMOUR Chair with Cup-holder of Godrej make for auditorium VIP seating OR Equivalent from HAWORTH / HERMAN MILLER / FIGUERAS DIAS Chair of Godrej make, model 7001D OR Equivalent from HAWORTH / HERMAN MILLER / FIGUERAS SS Chairs on beam for lobby seating Total Amount Page 14 Unit Qty. Nos. 966 Nos. 16 Nos. 8 Nos. 3 Rate Amount J SR. NO. 1 3 4 5 6 1 2 3 4 5 5.1 (a) (b) 6.1 6.2 6.3 6.4 6.5 7 7.1 7.2 8 9 10 J HVAC SYSTEM DESCRIPTION Supplying of factory built floor mounted double skin type air handling units suitable for VRF system, having multiple circuit with electronic expansion valve consisting of GI casing of thickness 0.6mm outside layer with CFC free polyurethane foam(PUF),thickness 23 ± 2 mm, density 40 ± 2 kg/cu.m. insulation, factory injected between them by injection molding machine, complete with blower section with blower suitable for static pressure as detailed below, minimum 2 bend GSS / PVC eliminators, cooling coil section with aluminum finned (Fin spacing 12 FPI, condensing tray made up of Aluminium, Test pressure - 38kg/ Sq.cm., Insulation material-13mm thick close cell Nitrile rubber, Make of insulation- Armacell) copper tubes (tube thickness not less than 0.41 mm, outside dia 12.7 mm, header material Copper, Coil casing GI) cooling coil, filter sections with 50mm thick metal viscous/ washable synthetic type pre-filters (EU-4) (Thermodyne/ AAF/ Spectrum make), belt driven fan (Nicotra / Kruger make, Type – DIDW Forward curved) with TEFC drive motor (ABB/ Crompton/ Siemens/ Havells make, η factor EFF-2) suitable for 415 ± 10% volts, 50 Hz, 3 phase, AC supply, drain connections, stainless steel drain pan thermometers and pressure gauges at the inlet and outlet of coil, necessary vibration isolation arrangement, mixing box with GI dampers etc. 20000 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 18000 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 8400 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 6850 CFM having 25 mm of Wg as min ESP & 6 row deep Coil Supply of the DC Inverter Technology based Multi V Plus III Outdoor units (R-410A) 20 HP 24 HP 56 HP 60 HP Expansion Kit Type 3 Communication Kit for AHU Wired Remote for AHU Sub-Total A PART _ B ITC of the following Multi-V Plus III static Ceiling Concealed Ductable indoor units with R-410A refrigerant and wired remote 20000 CFM 18000 CFM 8400 CFM 6850 CFM ITC of the of the DC Inverter Technology based Multi V Plus III Outdoor units with R 410 A Gas Charge 20 HP 24 HP 56 HP 60 HP SITC of the following sizes Cu. refrigerant pipes duly insulated with 19mm/13mm close cell elastometric nitrite rubber insulation between each set of outdoor and indoor units including refnet joints for VRF units. SITC of Drain Water pipe with insulation as per specification 32 mm NB Duct Work as per specification. G.I. Ducting including dampers, turning vanes, splitter dampers etc. as per required. 22 G 24 G Supply air grilles with VCD, Powder coated extruded aluminum Return air grilles without VCD, Powder coated extruded aluminum Supply Air Diffusers with VCD, Powder coated extruded aluminum Return Air Diffusers with VCD, Powder coated extruded aluminum Fusible link type fire damper at IDU supply duct Ducting Insulation as per specification. Supply & fixing of additional Thermal insulation for supply air duct using 9mm thick class " O " Closed cell nitrile rubber based elastomeric insulation. Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. Additional Duct Acoustic Insulation 12mm thick rigid board RB fiberglass. Electrical Control Cable Work including double earthing as per specn. Flexible Canvas Connection Underdeck Thermal Insulation with 50mm thick TF quality thermocole Sub-Total B Total Basic Taxes Grand Total Amount TECHNICAL SPECIFICATION AND APPROVED MAKE LIST QTY. UNIT 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 1.00 1.00 1.00 1.00 4.00 4.00 4.00 Nos Nos Nos Nos Nos Nos Nos 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 100.00 RMT 40.00 RMT 150.00 800.00 RO 15.00 10.00 RO 2.00 Sqm Sqm Sqm Sqm Sqm Sqm Sqm 800.00 Sqm 150.00 120.00 4.00 750.00 Sqm RMT Nos Sqm RATE AMOUNT 1 3 4 5 6 1 2 3 4 5 5.1 (a) (b) 6.1 6.2 6.3 6.4 6.5 7 7.1 7.2 8 9 10 Supplying of factory built floor mounted double skin type air handling units suitable for VRF system, having multiple circuit with electronic expansion valve consisting of GI casing of thickness 0.6mm outside layer with CFC free polyurethane foam(PUF),thickness 23 ± 2 mm, density 40 ± 2 kg/cu.m. insulation, factory injected between them by injection molding machine, complete with blower section with blower suitable for static pressure as detailed below, minimum 2 bend GSS / PVC eliminators, cooling coil section with aluminum finned (Fin spacing 12 FPI, condensing tray made up of Aluminium, Test pressure - 38kg/ Sq.cm., Insulation material-13mm thick close cell Nitrile rubber, Make of insulation- Armacell) copper tubes (tube thickness not less than 0.41 mm, outside dia 12.7 mm, header material Copper, Coil casing GI) cooling coil, filter sections with 50mm thick metal viscous/ washable synthetic type pre-filters (EU-4) (Thermodyne/ AAF/ Spectrum make), belt driven fan (Nicotra / Kruger make, Type – DIDW Forward curved) with TEFC drive motor (ABB/ Crompton/ Siemens/ Havells make, η factor EFF-2) suitable for 415 ± 10% volts, 50 Hz, 3 phase, AC supply, drain connections, stainless steel drain pan thermometers and pressure gauges at the inlet and outlet of coil, necessary vibration isolation arrangement, mixing box with GI dampers etc. 20000 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 18000 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 8400 CFM having 25 mm of Wg as min ESP & 6 row deep Coil 6850 CFM having 25 mm of Wg as min ESP & 6 row deep Coil Supply of the DC Inverter Technology based Multi V Plus III Outdoor units (R-410A) 20 HP 24 HP 56 HP 60 HP Expansion Kit Type 3 Communication Kit for AHU Wired Remote for AHU Sub-Total A PART _ B ITC of the following Multi-V Plus III static Ceiling Concealed Ductable indoor units with R-410A refrigerant and wired remote 20000 CFM 18000 CFM 8400 CFM 6850 CFM ITC of the of the DC Inverter Technology based Multi V Plus III Outdoor units with R 410 A Gas Charge 20 HP 24 HP 56 HP 60 HP SITC of the following sizes Cu. refrigerant pipes duly insulated with 19mm/13mm close cell elastometric nitrite rubber insulation between each set of outdoor and indoor units including refnet joints for VRF units. SITC of Drain Water pipe with insulation as per specification 32 mm NB Duct Work as per specification. G.I. Ducting including dampers, turning vanes, splitter dampers etc. as per required. 22 G 24 G Supply air grilles with VCD, Powder coated extruded aluminum Return air grilles without VCD, Powder coated extruded aluminum Supply Air Diffusers with VCD, Powder coated extruded aluminum Return Air Diffusers with VCD, Powder coated extruded aluminum Fusible link type fire damper at IDU supply duct Ducting Insulation as per specification. Supply & fixing of additional Thermal insulation for supply air duct using 9mm thick class " O " Closed cell nitrile rubber based elastomeric insulation. Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. Additional Duct Acoustic Insulation 12mm thick rigid board RB fiberglass. Electrical Control Cable Work including double earthing as per specn. Flexible Canvas Connection Underdeck Thermal Insulation with 50mm thick TF quality thermocole Total Amount 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 1.00 1.00 1.00 1.00 4.00 4.00 4.00 Nos Nos Nos Nos Nos Nos Nos 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 1.00 1.00 1.00 1.00 Nos Nos Nos Nos 100.00 RMT 40.00 RMT 150.00 800.00 RO 15.00 10.00 RO 2.00 Sqm Sqm Sqm Sqm Sqm Sqm Sqm 800.00 Sqm 150.00 120.00 4.00 750.00 Sqm RMT Nos Sqm K ELECTRICAL WORK of HVAC Sr. No. Item Description 1.0 Power Distribution Board The type of DB shall be vertical or horizontal based on design and site conditions. MCB DB - Vertical /horizontal type Incomer - 700 A, DP MCB Outgoing - 200A, SP, MCB - 3 nos. ( 2W+1SB) Outgoing - 100A, SP, MCB- 3 nos. ( 2 W+1SB) Outgoing - 63 A, SP, MCB - 5 nos. (4 W+1SB) PVC insulated, steel armoured, copper conductor 4 core cables. 1.1 kV grade armored PVC / XLPE insulated, steel armoured, copper conductor power cables. The cables shall be laid in tray / wall including termination with single compresson gland. 4 C x 50 sq.mm (XLPE) 4 C x 16 sq.mm (XLPE) 4 Cx 10 sqmm ( XLPE) Earth Strips Supply and laying GI earth strips on cable tray or below ground as per site condition. Earth strip joints should have welded joints only. 25 x 3 mm GI. strip 8SWG GI Wire Miscellaneous Items MS Painted Perforated Cable Tray Prefabricated - cable trays - made out of 2 mm thick galvised sheet. Rate shall include necessary angle iron support and M10 full threaded down rods, M10 anchor fasteners etc., complete. Maximum height of suspension shall not exceed 500mm. The support shall be provided at every 1 Mtr. Size of Cable Tray :150 mm x 50 mm Size of Cable Tray :100 mm x 50 mm Total Amount 1.1 2.0 2.1 2.2 2.3 3 3.1 3.2 4 4.1 4.2 Qty. Unit 1 Nos. 150 90 100 Rmt Rmt Rmt 360 100 Rmt Rmt 160 250 Rmt. Rmt. Rate Amount