CuSn/MGT/EPR/IS/SW4/GSWB/SW4 150/250V Fire resistant, flame retardant halogen-free instrumentation cable. Enhanced oil-resistance. RoHS RoHS 2002/95/WE BITNER CuSn/MGT/EPR/IS/SW4/GSWB/SW4 150/250V LVD 2006/95/WE Technical data: Construction: Operating temperature: 90°C Operating Voltage: 150/250V Min bending radius during installation: 10 x D Min bending radius for fixed Installation: 8 x D Max Tensile Load During Installation: 50 N /mm² MinInstallation Temperature -20°C Conductor: Multi-stranded tinned copper, 0.75, 1.0mm (BS6360, IEC 60228 class 5) Insulation: Mica Glass Tape / EPR rubber, GP4 acc. to BS 7655: section 1.2 Pair/Triple/Quad twisting / lay up: Cores twisted together to form a pair, triple or quad, which is individually screened with aluminium backed polyester tape with a tinned copper drain wire. Each pair, triple or quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs, triples or quads. Individually shielded pairs, triples or quads are laid up in concentric layers and wrapped with a PETP tape. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors. Inner sheath: Flame retardant and halogen-free thermoset compound Tape over inner sheath: PET tape + rubberized Polyamide tape Armour: Galvanized steel wire braid Tape over armour: PET tape + rubberized Polyamide tape Outer sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 acc. to BS 7655 section 2.6 Outer sheath colour: Grey or Blue Standards applied: BS 7917 / BS6883 / UKOOA - Design BS 6360 class 2 or 5 - Conductor BS 7655 section 1.2 - Insulation BS 7655 section 2.6 - Sheath IEC 60332-1- Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke Application: Fixed installation for instrumentation, communication, control and alarm systems in both EX– and safe areas, emergency and critical systems where there is a requirement for fire resistant cables. Core identification: Pair - Black - White, numbered Triple - Black - White - Red, numbered Quad - Black - White - Red - Blue, numbered Electrical parameters: Nominal Capacitance [nF/km] Type Shielded pair 0,75 mm2 2 Shielded triple 0,75 mm 2 Shielded quad 0,75 mm 2 Shielded pair 1,0 mm 2 Shielded triple 1,0 mm 2 Shielded quad 1,0 mm 90 90 90 100 100 100 Nominal Inductance [mH/km] Resistance at 20°C, max. [Ohm/km] 0,85 0,85 0,85 0,80 0,80 0,80 L/R ratio, [microH/Ohm] 26,7 26,7 26,7 20,0 20,0 20,0 ® 36 www.bitner.com.pl export@bitner.com.pl 20 20 20 25 25 25 CuSn/MGT/EPR/IS/SW4/GSWB/SW4 150/250V Fire resistant, flame retardant halogen-free instrumentation cable. Enhanced oil-resistance. Construction: Paired cables n x 2 x mm 2 1x2x0,75 3x2x0,75 7x2x0,75 12x2x0,75 20x2x0,75 27x2x0,75 37x2x0,75 1x2x1,0 3x2x1,0 7x2x1,0 12x2x1,0 20x2x1,0 27x2x1,0 37x2x1,0 Conductor diameter [mm] Insulation Thickness [mm] 1,15 1,15 1,15 1,15 1,15 1,15 1,15 1,3 1,3 1,3 1,3 1,3 1,3 1,3 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 Inner Sheath Thickness [mm] 1,0 1,2 1,4 1,6 1,9 2,0 2,2 1,0 1,3 1,4 1,7 1,9 2,1 2,3 Nominal Inner Sheath Diameter [mm] 8,95 15 20,05 25,1 26,95 36,25 42,4 9,4 16 21,25 26,7 33,7 38,5 45 Braid Wire Diameter [mm] Outer Sheath Thickness [mm] 1,2 1,4 1,6 1,8 2,1 2,3 2,5 1,2 1,4 1,6 1,9 2,2 2,4 2,6 0,3 0,3 0,3 0,3 0,45 0,45 0,45 0,3 0,3 0,3 0,45 0,45 0,45 0,45 Nominal Outer Diameter [mm] Nominal Cable Weight [kg/km] 12,8 19,3 24,95 30,3 38,5 43,45 49,8 13,25 20,3 26,05 33,05 40,7 45,9 52,85 260 530 790 1280 1980 2410 3120 270 550 850 1395 2210 2780 3570 *- cable sizes out of range of BS 7917, construction according to factory standard Triple cables n x 3 x mm2 Conductor diameter [mm] Insulation Thickness [mm] Inner Sheath Thickness [mm] 1x3x0,75 3x3x0,75 7x3x0,75 12x3x0,75 1x3x1,0 3x3x1,0 7x3x1,0 12x3x1,0 1,15 1,15 1,15 1,15 1,3 1,3 1,3 1,3 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 1,0 1,3 1,5 1,7 1,1 1,3 1,5 1,8 Nominal Inner Sheath Diameter [mm] 8,95 16 22,05 27,15 9,6 16,85 23,25 28,85 Braid Wire Diameter [mm] Outer Sheath Thickness [mm] 1,2 1,5 1,7 2,0 1,2 1,5 1,7 2,0 0,3 0,3 0,3 0,45 0,3 0,3 0,3 0,45 Nominal Outer Diameter [mm] Nominal Cable Weight [kg/km] 12,8 20,7 27,05 33,7 13,45 21,55 28,25 35,4 300 630 1240 1680 330 660 1290 1810 *- cable sizes out of range of BS 7917, construction according to factory standard Quad cables n x 4 x mm2 1x4x0,75 3x4x0,75 7x4x0,75 1x4x1,0 3x4x1,0 7x4x1,0 Conductor diameter [mm] Insulation Inner Sheath Thickness Thickness [mm] [mm] 1,15 1,15 1,15 1,3 1,3 1,3 0,8 0,8 0,8 0,8 0,8 0,8 1,1 1,4 1,6 1,1 1,4 1,6 Nominal Inner Sheath Diameter [mm] 10 18,45 24,8 10,5 19,5 26,25 Braid Wire Diameter [mm] Outer Sheath Thickness [mm] 0,3 0,3 0,3 0,3 0,3 0,45 1,2 1,5 1,7 1,2 1,6 1,8 Nominal Outer Diameter [mm] Nominal Cable Weight [kg/km] 13,8 23,35 30,0 14,3 24,4 32,4 340 660 1270 360 710 1400 *- cable sizes out of range of BS 7917, construction according to factory standard ® www.bitner.com.pl export@bitner.com.pl 37