TXOI(i) 250V(1).doc 21.06.2006 14:46 Page 1 of 2 Shipline TXOI(i) 250V Instrumentation cable Flame retardant halogen-free instrumentation cable. Braided. Individual pair shielded. TXOI(I) 250V HFXLPE/TCWB/PO Operating temperature Operating Voltage : 90°C : 250V Standards applied Application Armoured cable for fixed installation in ships where cable protection is required. Suitable for use on instrumentation and communication systems. Can be installed and operated both indoors and outdoors. IEC 60092-376 IEC 60228 class 2 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 600754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Annealed stranded circular copper, IEC 60228 class 2 T Pair / Triple / Quad twisting Lay up / Shielding Inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Outer sheath colour X O I Crosslinked Polyethylene, IEC 60092-351 (HFXLPE) Numbered white cores are twisted together and wrapped with polyester tape. Pairs/Quads are laid up and individually shielded by aluminium backed polyester tape with tinned copper drain wire. Each pair/quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs/quads. Pairs/quads are identified by numbers printed on the insulated cores. Individually shielded pairs are laid up in concentric layers and wrapped with a PETP tape. No inner covering. Two tapes substitutes the extruded covering. All tapes are halogen-free. Tinned copper wire braid Additional tape may be applied Flame retardant halogen-free thermoplastic compound, SHF1 E.g. "meter" "year" DRAKA NORSK KABEL TXOI(i) 250V 2 PAIR 0,75 mm2 IEC 60092-376 IEC 60332-3-22 ShipLine Grey www.drakaMOG.com Subject to change without prior notice TXOI(i) 250V(1).doc 21.06.2006 14:46 Page 2 of 2 Shipline TXOI(i) 250V Instrumentation cable Core identification instrumentation cables The pairs have the following number identification according to IEC 60092-376 Pair no.1 Pair no. 2 Pair no. 3 Pair no. 4 Pair no. 5 Core no. 1-2 3-4 5-6 7-8 etc - etc Range and dimensions No of Number of cores in elements element 2 4 7 2 2 2 Cross section core, mm² 0.75 0.75 0.75 Conductor Diameter, mm Insulation Thickness, mm 1.1 1.1 1.1 0.5 0.5 0.5 Weight of Diameter Thickness Diameter Cable Braid Wire, Outer outer Approx. mm Sheath, mm sheath, mm (Kg/Km) 0.2 1.1 10.5 ± 0.8 150 0.2 1.2 12.5 ± 0.8 225 0.3 1.3 15.5 ± 0.8 380 Copper content Approx. (kg/km) 81 124 226 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) Shielded pair 0,75 mm² 70 0.64 26.0 Ordering information Part number 832482 832484 832486 Description TXOI(I) 250V 2PAIR 0.75mm² TXOI(I) 250V 4PAIR 0.75mm² TXOI(I) 250V 7PAIR 0.75mm² Sheath Colour GREY GREY GREY EAN No. DNK 7021528324822 7021528324846 7021528324860 EL No. - Installation recommendations Minimum Bending Radius during Installation 8xD Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² www.drakaMOG.com Subject to change without prior notice Minimum Installation Temperature -10°C