C O M P O N E N T S AC Vacuum Circuit-Breaker type BVAC for electrical traction vehicles General The Sécheron type BVAC circuit-breaker is a roof mounted way applications. It is equipped with a vacuum switch tube, pneumatic closing, electromagnetic holding and opening through spring induced force. The BVAC is used as the main line breaker to switch ON and OFF the traction power circuit, as well as to interrupt the overloads and shortcircuit currents. It can replace the type DBTF air blast circuit-breaker without modification of the roof. As an option, the BVAC can be equipped with an earthing switch type BTE 15/25.04. F A B G BVAC BTE D C A: towards pantograph B: towards transformer C: grounding circuit D: earthing switch type BTE (option) F: pantograph G: transformer Description Vacuum Switch Tube (VST) Main contacts B HV connection HV connection A Insulating rod (T) Earth Vehicle's roof Base frame Pneumatic circuit LV connector Electro-valve (EV) Piston (K) Auxiliary contacts Holding coil (M) Operation The operation of the BVAC breaker includes 3 steps. Closing (pneumatic) The BVAC is closed by actuation of the solenoid valve (EV). Moved by the piston (K) and the isolating rod (T), a mécanism closes the the mains contacts inside the vacuum switch tube (VST) and prestress the opening springs. Holding (electro-magnetic) The pneumatic cylinder is equipped with a holding electro-magnet (M), which holds the BVAC in the closed position, without air pressure. Tripping The opening of the BVAC is caused by the prestressed springs release, which occurs when the holding current is cut off. Standard version ordering designation code AC vacuum circuit-breaker BVAC 1 0 1 0 0 V1 0 Rated operational voltage 17.5 kV: 30.0 kV: Without: BTE on right side: BTE on left side: 24 V DC: 36 V DC: 48 V DC: 72 V DC: 110 V DC: Without: Sicem 35 poles: Standard: 5 switches: Connections for earthing switch type BTE Nominal control voltage Lightning arrester Low voltage connector Control circuit Auxiliary contacts 1 2 0 3 4 1 2 3 4 5 0 0 V1 0 The order acknowledgement codification differs from the ordering one. Note: when ordering spare BVAC version delivered before March 2006, provide Sécheron with the part number of the delivered product. Technical data Main Circuit Rated operational voltage Rated insulation voltage Rated power frequency withstand voltage Rated impulse withstand voltage Rated operational current Conventional free air thermal current Rated operational frequency Frequency of operation Rated short-circuit making capacity Rated short-circuit breaking capacity Rated short time withstand current Opening time Outdoor pollution degree Indoor pollution degree Auxiliary Circuit Nominal voltage Maximum closing power (Dt EV = ~0.6 s) Nominal holding power* Number of auxiliary contacts Air pressure Air supply pipe diameter Ambient temperature Weight Symbol Unit BVAC 1... BVAC 2... Ue Ui U 50 U imp Ie I th f V V kVrms kV A A Hz I cw Dt o kA kArms/% kA ms 17’500 17’500 45 95 1000 1000 16 2/3 C3 62.5 25/50 25 / 1s 20..60 PD4 PD3 30’000 30’000 75 170 1000 1000 50/60 C3 50 20/50 25 / 1s 20..60 PD4 PD3 Un (2) Vdc W W bar °C kg 24 / 36 / 48 / 72 / 110 50-200 50-200 15-50 15-50 5 5 4.5-10 4.5-10 G 3/8 G 3/8 -40..+70 -40..+70 120 135 Compliant to the standards IEC 60077-1/2/4, NF F16-101 grid 18 and NF F 16-102 level 1 The BVAC 2… is designed for a rated operational voltage of 30 kV, but can also be used for a rated operational voltage of 17.5 kV with the same performances as the BVAC 1… * Depending on the selected control voltage. 3 Options BVAC 1 0 1 1 2 V2 1 Lightning arrester: Low Voltage connector: With Sicem 31 poles Harting 16 poles compatible with all former BVAC versions from 1 to 6 additional switches Control circuit: Auxiliary contacts 1 1 2 V2 1...6 Main dimensions HV M12 586 HV M12 Ø 30 A G 3/8" 142 480 870 15 kV : 490 25 kV : 560 15 kV : 339 25 kV : 409 B 200 65 230 71 62 43 15 kV : 439 25 kV : 509 2 C 320 Left 6 x Ø14 220 85 2 x Ø12 430 Roof opening Back Front 920 880 940 40 20 420 20 420 SG310272BEN_A02-1.06 A: connection for air supply B: base frame level C: space to remove the cover Sécheron SA Rue du Pré-Bouvier 25 1217 Meyrin - Geneva CH-Switzerland 40 410 330 385 Right 6 x M12 30 x 45˚ Tel: +41 22 739 41 11 Fax: +41 22 739 48 11 info@secheron.com www.secheron.com This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser's responsibility to inform himself, no matter what the circumstances, of the product's maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our "General Delivery Conditions". Copyright© 2007 Sécheron SA