Calculite® Incandescent Open Downlight E7059

advertisement
Calculite® Incandescent Open Downlight
Page 1 of 2
E7059
6" Aperture A19 / A21 Horizontal Lamp
2
1
Top View
5
5-7/8"
12-3/4"
3"
6
4-1/2"
10-1/4"
13-1/4"
1" min.2-1/8" max.
(Ceiling Runner)
3
4
6-1/2"
Flush
Molded
Trim Ring
Flush Trim
(Molded trim
ring removed)
7
6" Dia.
1-1/8" max.
Ceiling Thickness
7-1/4"
Overlap
Overlap Self-Flange
Matte White
or polished
Ceiling Cutout: 6 9/16" Dia.
Reflector Trims
Frame-In Kit
Lamp
E7059CLW
E7059CLP
E7059CL
E7059
E610
A19, 100W max.
A21, 150W max.
Specular Clear finish with white flange
Specular Clear finish with polished flange
Specular Clear finish with molded trim ring (flangeless)
Add suffix for other finishes (see options)
Features
Options & Accessories
1. Socket Cup: Heat dissipating die-formed aluminum contains medium base
porcelain socket with nickel plated screw shell wired with No 18 SF1 leads
to J-Box. Installs on reflector with positive position locking springs to assure
proper optical alignment of lamp to reflector — attached without tools. Can
be adjusted without tools to accommodate two different lamp sizes.
2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga.
steel construction. Use with 3/4" or 1 3/4" lathing channels, or1/2" (11/16"
O.D.) EMT pipe (by others) or Lightolier accessory mounting bars.
3. Retaining Springs: Precision tooled springs secure reflector to mounting
frame for quick tool-less installation.
4. Reflector: 16 ga. Specular Alzak® aluminum, 50° visual cut-off to lamp and
lamp image. Available with white or polished flange, or with removable
white molded trim ring (field paintable).
5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box allows inspection from
below.
6. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings.
Provides flangeless trim in plaster ceiling.
18" Mounting Bars
27" Mounting Bars
T-Bar Anchor Clips
Existing Ceiling Clips
Sloped Ceiling Adapters
Step Down Transformer
Chicago Air Plenum
Electrical
UL listed for maximum of 8 No. 12, 75°C through branch circuit supply conductors, or 60°C conductors for end of run.
Labels
UL Listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.
Job Information
Other Reflector Finish Options
Job Name:
Comfort Clear Diffuse
Specular Gold
Cat. No.:
CCD
GD
For additional finishes consult factory (GD not available with polished flange)
Lamp(s):
Flange Options
Notes:
White
Polished Flange
Flangeless
1950 (set of 2)
1951 (set of 2)
1956 (set of 4, for 1950 & 1951 bars)
7998 (set of 2)
7920 (see SCA specification sheet)
7997 (see 7997 specification sheet)
LC (add suffix to Frame-in Kit)
Type:
W
P
Leave Blank (molded trim ring)
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Calculite® Incandescent Open Downlight
Initial Footcandles
Page 2 of 2
E7059
6" Aperture A19 / A21 Horizontal Lamp
60
150 Watt A-21
2880 Lumens Per Lamp
50
RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)
RCR = 10 (Rm. Width - Mtg. Ht. above work plane)
Room Surface Reflectances:
80% Ceiling; 50% Walls; 20% Floor
40
30
20
20
50
100
150
200
Area Per Fixture In Square Feet
5
6
8
7
9
10
11
12
13
14
15
Center To Center Distance Of Fixtures In Feet
Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factor: 100W A19 (Clear): F.C. X 0.60; (Gold): F.C. x 0.55 150W A21 (Gold):
F.C. x 0.90.
Spacing Ratio = 1.3
Candlepower Summary
90
60
180°
Plane
90°
Plane
0°
Plane
30
30
DEG. 0
0 1238
5 1297
15 1828
25 1859
35 940
45 165
55 4
65 1
75 1
85 0
90 0
45
1238
1304
1690
1971
954
157
4
1
1
0
0
90
1238
1282
1620
1834
938
140
4
1
1
0
0
135
1238
1246
1455
1617
831
105
3
1
1
0
0
180
1238
1218
1318
1362
751
83
3
1
1
0
0
ZONAL
FLUX
121
448
814
560
102
3
1
1
0
Zonal Summary
ZONE LUMENS LAMP FIXT
0-30
0-40
0-60
0-90
90-180
0-180
ITL, Inc. test report No. 22532
Date: 10-26-77
1383
1943
2048
2050
0
2050
48.0 67.5
67.5 94.8
71.1 99.9
71.2 100.0
0.0
0.0
71.2 100.0
Coefficients of Utilization
% Effective Ceiling Cavity Reflectance
80
70
50
30
10
0
Room Cavity Ratio
% Wall Reflectance
1
2
3
4
5
6
7
8
9
10
50
.80
.75
.71
.67
.63
.60
.56
.53
.49
.47
30
.78
.73
.68
.63
.59
.56
.52
.49
.46
.43
10
.76
.70
.65
.61
.57
.53
.50
.46
.43
.40
50
.78
.74
.70
.66
.62
.59
.56
.52
.49
.46
30
.77
.72
.67
.63
.59
.56
.52
.49
.45
.43
10
.75
.70
.65
.61
.56
.53
.49
.46
.43
.40
50
.75
.72
.68
.65
.61
.58
.55
.52
.48
.46
30
.74
.70
.66
.62
.58
.55
.52
.48
.45
.42
10
.73
.68
.64
.60
.56
.53
.49
.46
.43
.40
50
.73
.69
.66
.63
.60
.57
.54
.51
.48
.45
30
.72
.68
.64
.61
.57
.54
.51
.48
.45
.42
10
.71
.67
.63
.59
.55
.52
.49
.46
.43
.40
50
.70
.68
.65
.62
.59
.56
.53
.50
.47
.45
30
.69
.66
.63
.60
.57
.54
.51
.48
.44
.42
10
.69
.65
.62
.58
.55
.52
.49
.46
.42
.40
0
.68
.64
.61
.58
.54
.51
.48
.45
.41
.39
20% Floor Cavity Reflectance
Job Information
Type:
Lightolier a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902