Low Voltage Final
Distribution Products
Leading Low-voltage Electrical Component Manufacturer
Low Voltage Final
Distribution Products
Miniature Circuit Breakers
Product Overview
NDM1-63 Series Miniature Circuit Breaker
NDB1 Series Miniature Circuit Breaker (1P+N)
NDB2-63 Series Miniature Circuit Breaker
NDB2-63K Series Miniature Circuit Breaker
NDB2T-63 Series Miniature Circuit Breaker
NDM1-125 Series Miniature Circuit Breaker
NDB6-125 Series Miniature Circuit Breaker
DC Application of NDM1 Series MCB
NDB2Z-63 Series DC Miniature Circuit Breaker
Tripping Curves
Temperature Derating
Accessories for Miniature Circuit Breaker (AS/FC/ST, Busbar)
NDG1 Series Disconnect Switch
03
05
08
10
13
15
18
20
22
23
26
27
28
33
Residual Current Protective Devices
Product Overview
NDM1L Series Residual Current Unit
NDM1LG Series Overvoltage Protection Residual Current Unit
NDB1L Series RCBO (1P+N)
NDB1LG Series RCBO with Overvoltage Protection (1P+N)
NDB2LE Series RCBO
NDB6LM Series RCBO (1P+N)
NDL6M Series RCCB
35
37
40
42
44
46
49
53
Modular Socket
NDA1 Series Modular Socket
NDA3 Series Modular Socket
01
58
59
02
Product Overview of Miniature Circuit Breakers
Product name
Standard MCB
SPN MCB
Product pange
NDM1-63
NDB1-32
Product Overview of Miniature Circuit Breakers
High Breaking
Capacity MCB
NDB2-63
High Breaking
Capacity MCB
NDB6-125
DC MCB
Disconnect Switch
NDB2Z-63
NDG1-100
Standard
IEC 60947-2
IEC 60947-2
IEC 60947-2
IEC 60898-2
Number of poles
1
1
1
1
NDB2-63K
Product range
Product picture
Standards
IEC 60898-1
Number of pole
1
2, 3, 4
IEC 60898-1
1P+N
IEC 60898-1
1
2, 3, 4
IEC 60898-1
1P+N
Electrical characteristics
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
IEC 60947-3
1, 2, 3, 4
Electrical characteristics
Rated current(A) In
1~63
AC230V, AC230V/400V,
DC60V DC60V
AC rated short-circuit capacity (kA)
Rated voltage(V) Ue
B/C Curve: 6 (In ≤40A),
4.5 (In >40A)
D Curve: 4.5
IEC60898 standard (Icn)
6~32
1~63
6~63
AC230V
AC230V, AC230V/400V,
DC60V DC60V
AC230V
4.5
10
6
IEC60947-2 standard (Icu)
DC rated short-circuit
capacity (A)
Rated current(A) In
1~63
Mech. Service life (times)
2
Connection capacity (mm )
10
C
B/C/D
C
20000
10000
20000
20000
Mech. Service life (times)
35
Auxiliary switches
Alarm switches
Shunt trip
Connection capacity (mm )
10
——
35
Auxiliary switches
Alarm switches
Shunt trip
50~125
1~63
32, 63, 100
AC 230/400V
IEC60898 standard (Icn)
B/C/D (D curve is
not for 50A, 63A)
25
Auxiliary switches
Alarm switches
Shunt trip
50~125
AC230V, AC230V/400V, AC230V, AC230V/400V, AC230V, AC230V/400V, DC125V, DC250V,
Rated voltage(V) Ue
DC220V DC440V
DC60V DC60V
DC60V DC60V
DC60V DC60V
AC rated short-circuit capacity (kA)
IEC60947-2 standard (Icu)
DC rated short-circuit
capacity (A)
Tripping curve type
03
High Breaking
Capacity MCB
NDM1-125
Product name
Product picture
Electrical auxiliaries
High Breaking
Capacity MCB
NDB2T-63
SPN MCB
Tripping curve type
B/C/D
2
Electrical auxiliaries
20000
10
15
C/D (Only C Curve C/D (Only C Curve
available for 125A) available for 125A)
10000
35
50
Auxiliary switches Auxiliary switches
Alarm switches
Alarm switches
Shunt trip
Shunt trip
10000
50
——
10 (DC125V)
6 (DC220V)
B/C
20000
10000
35
50
Auxiliary switches
Alarm switches Auxiliary switches
Shunt trip
04
Specifications
Working Condition
Ambient temperature: -35℃~+70℃
Rated working voltage: AC230/400V, DC60V
Air humidity: ≤95%
Rated working current: 1A - 63A
Altitude: ≤2000m
Mechanical life: 10000 times
Pollution degree: Ⅱ
Tripping characteristic: B: 3-5In; C: 5-10In; D: 10-14In
Breaking capacity:
Rated current(A)
Voltage(V)
Breaking capacity(kA)
B、C: 1-40
AC230/400
6
AC230/400
4.5
AC230/400
4.5
50, 63
D
Product Features
: 1-40
Modularized
Screw clamp, shock-proof wiring terminals
Wiring Capacity
Numerous accessories available
Standard TH35mm DIN rail mounting
≤25mm2
RoHS complied
NDM1-63 Series Miniature Circuit Breaker
Application
Dimension
Curve B: Non-inductive or micro-inductive loads
Curve C: Usual inductive loads
Curve D: Highly inductive loads
Overload and short circuit protection
63
18
ND M 1
26.5
Model and Implication
7
Implication
No.
45.5
5.5
NDM1-63
Design code
1
Frame rating (A)
63
Instantaneous tripping characteristic
B, C, D
Rated current (A)
1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles
1, 2, 3, 4
1P 18max
2P
Standards and Certificates
3P
4P
45
M Miniature Circuit Breaker
80.5max
Brand code
Product code
60
36max
54max
72.5max
72max
IEC 60898-1, GB 10963.1;
TÜV, CE and CCC.
05
06
Number of Poles
Curve
Width
(mm)
1
B, C, D
1P
18
2
B, C
1
3
B, C, D
36
2P
2
4
B, C
1
3
5
B, C, D
54
3P
2
4
6
B, C
1
3
5
7
B, C, D
4P
72
2
4
6
8
B, C
07
Rated
Current(A)
1
2
3
4
5
6
10
16
20
25
32
40
50
63
1
2
3
4
5
6
10
16
20
25
32
40
50
63
1
2
3
4
5
6
10
16
20
25
32
40
50
63
1
2
3
4
5
6
10
16
20
25
32
40
50
63
Part No.
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
NDM1-63
1/1
2/1
3/1
4/1
5/1
6/1
10/1
16/1
20/1
25/1
32/1
40/1
50/1
63/1
1/2
2/2
3/2
4/2
5/2
6/2
10/2
16/2
20/2
25/2
32/2
40/2
50/2
63/2
1/3
2/3
3/3
4/3
5/3
6/3
10/3
16/3
20/3
25/3
32/3
40/3
50/3
63/3
1/4
2/4
3/4
4/4
5/4
6/4
10/4
16/4
20/4
25/4
32/4
40/4
50/4
63/4
NDB1 Series Miniature Circuit Breaker (1P+N)
Application
TT/TN-S grounding system
Phase and neutral protection against short circuit and overload
Model and Implication
ND B 1
32 C
Implication
No.
NDB1-32
Brand code
Product code
B Miniature Circuit Breaker
Design code
1
Frame rating (A)
32
Instantaneous tripping characteristic
C
Rated current (A)
6, 10, 16, 20, 25, 32
Standards and Certificates
IEC 60898-1, GB 10963.1; CCC.
Working Condition
Specifications
Ambient temperature: -35℃~+70℃
Rated working voltage: AC230V
Air humidity: ≤95%
Mechanical life: 10000 times
Altitude: ≤2000m
Tripping characteristic: C: 5-10In
Pollution degree: Ⅱ
Breaking capacity: 4.5kA
Wiring Capacity
≤10mm2
06
08
NDB2-63 Series Miniature Circuit Breaker
Application
Curve B: Non-inductive or micro-inductive loads
Curve C: Usual inductive loads
Curve D: Highly inductive loads
Overload and short circuit protection
Model and Implication
ND B 2
63
7
Implication
No.
NDB2-63
Brand code
Product code
Product Features
18max
circuit opens or trips because of failure
5.5
Design code
2
Frame rating (A)
63
Instantaneous tripping characteristic
B, C, D
Rated current (A)
1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles
1, 2, 3, 4
Dimension
Phase and neutral are both switched when
B Miniature Circuit Breaker
70.5max
60
40
Standards and Certificates
Neutral line connected early and
disconnected late
UL1077, IEC60898-1, GB 10963.1;
Standard TH35mm DIN rail mounting
45
80max
Screw clamp, shock-proof wiring terminals
UL1077, TÜV, CE, CCC.
RoHS complied
Working Condition
Number of Poles
1P+N
09
Curve
C
Width (mm)
18
Rated Current (A)
Part No.
6
NDB1-32
6
10
NDB1-32
10
16
NDB1-32
16
20
NDB1-32
20
25
NDB1-32
25
32
NDB1-32
32
Specifications
Ambient temperature: -35℃~+70℃
Rated working voltage: AC230/400V, DC60V
Air humidity: ≤95%
Rated working current: 1A - 63A
Altitude: ≤2000m
Mechanical life: 20000 times
Pollution degree: Ⅱ
Tripping characteristic: B: 3-5In; C: 5-10In; D: 10-14In
Breaking capacity:
Product Features
Rated current
(A)
Voltage (V)
Breaking
capacity(kA)
1~63
AC230/400
10
High breaking capacity
Modularized
Visual indicator
Screw clamp, shock-proof wiring terminals
Numerous accessories available
Standard TH35mm DIN rail mounting
Wiring Capacity
≤35mm2
RoHS complied
10
Number of Poles
Curve
Width
(mm)
3
1
B, C, D
2P
2
36
4
Dimension
4P
3P
2P
72max
74max
54max
1
60
36max
45
1P 18max
5
3
B, C, D
3P
6
4
21
45
81.5
2
54
5.5
Number of Poles
Curve
Width (mm)
1
1P
B, C, D
2
11
18
Rated
Current (A)
Part No.
Rated
Current (A)
Part No.
1
NDB2-63
1/2
2
NDB2-63
2/2
4
NDB2-63
4/2
6
NDB2-63
6/2
10
NDB2-63
10/2
16
NDB2-63
16/2
20
NDB2-63
20/2
25
NDB2-63
25/2
32
NDB2-63
32/2
40
NDB2-63
40/2
50
NDB2-63
50/2
63
NDB2-63
63/2
1
NDB2-63
1/3
2
NDB2-63
2/3
4
NDB2-63
4/3
6
NDB2-63
6/3
10
NDB2-63
10/3
16
NDB2-63
16/3
20
NDB2-63
20/3
25
NDB2-63
25/3
32
NDB2-63
32/3
40
NDB2-63
40/3
50
NDB2-63
50/3
63
NDB2-63
63/3
1
NDB2-63
1/4
2
NDB2-63
2/4
4
NDB2-63
4/4
6
NDB2-63
6/4
10
NDB2-63
10/4
16
NDB2-63
16/4
20
NDB2-63
20/4
25
NDB2-63
25/4
1
NDB2-63
1/1
2
NDB2-63
2/1
4
NDB2-63
4/1
6
NDB2-63
6/1
10
NDB2-63
10/1
16
NDB2-63
16/1
20
NDB2-63
20/1
32
NDB2-63
32/4
25
NDB2-63
25/1
40
NDB2-63
40/4
32
NDB2-63
32/1
40
NDB2-63
40/1
50
NDB2-63
50/4
50
NDB2-63
50/1
63
NDB2-63
63/4
63
NDB2-63
63/1
1
3
5
7
4P
B, C, D
2
4
6
8
72
12
Specifications
Working Condition
Rated working voltage: AC230V
Ambient temperature: -35℃~+70℃
Mechanical life: 20000 times
Air humidity: ≤95%
Tripping characteristic: C: 5-10In
Altitude: ≤2000m
Breaking capacity: 6kA
Pollution degree: Ⅱ
Product Features
Dimension
Phase and neutral are both switched when circuit opens
or trips because of failure
74max
Neutral line connected early and disconnected late
Screw clamp, shock-proof wiring terminals
60
36max
45
45
81.5
Standard TH35mm DIN rail mounting
21
Wiring Capacity
NDB2-63K Series Miniature Circuit Breaker
5.5
≤35mm2
Application
TT/TN-S grounding system
Phase and neutral protection against short circuit and overload
Number of Poles
Curve
Width (mm)
Model and Implication
ND B 2
63 K C
7
No.
Implication
1P+N
NDB2-63K
Brand code
C
36
Rated Current (A)
Part No.
6
NDB2-63K
6
10
NDB2-63K
10
16
NDB2-63K
16
20
NDB2-63K
20
25
NDB2-63K
25
32
NDB2-63K
32
40
NDB2-63K
40
Product code
B Miniature Circuit Breaker
50
NDB2-63K
50
Design code
2
63
NDB2-63K
63
Frame rating (A)
63
Phase line + Neutral line
K
Instantaneous tripping characteristic
C
Rated current (A)
6, 10, 16, 20, 25, 32, 40, 50, 63
Standards and Certificates
IEC 60898-1, GB 10963.1; CCC
13
14
Specifications
Working Condition
Ambient temperature: -35℃~+70℃
Rated working voltage: AC230/400V, DC60V
Air humidity: ≤95%
Rated working current: 1A - 63A
Altitude: ≤2000m
Mechanical life: 20000 times
Pollution degree: Ⅲ
Rated impulse withstand voltage: 6kV
Tripping characteristic:
B: 4In±20%; C: 8In±20%; D: 12In±20%
Breaking capacity
Rated current
(A)
Product Features
High breaking capacity
1~63
Modularized
Voltage (V)
Breaking
capacity(kA)
AC230/400
10
Visual indicator
Screw clamp, shock-proof wiring terminals
Numerous accessories available
Wiring Capacity
Standard TH35mm DIN rail mounting
≤35mm2
RoHS complied
Dimension
NDB2T-63 Series Miniature Circuit Breaker
Application
4P
3P
Curve B: Non-inductive or micro-inductive loads
2P
Curve C: Usual inductive loads
72max
74max
54max
60
36max
45
1P 18max
Curve D: Highly inductive loads
21
45
81.5
Overload and short circuit protection
Model and Implication
ND B 2T
63
5.5
7
No.
Implication
NDB2T-63
Number of Poles
Curve
Width
(mm)
Brand code
Product code
B Miniature Circuit Breaker
Design code
2T
Frame rating (A)
63
Instantaneous tripping characteristic
B, C, D
Rated current (A)
1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles
1, 2, 3, 4
1
1P
B, C, D
2
Standards and Certificates
IEC60947-2, GB 14048.2; CB, CCC.
15
18
Rated Current
(A)
Part No.
1
NDB2T-63
1/1
2
NDB2T-63
2/1
4
NDB2T-63
4/1
6
NDB2T-63
6/1
10
NDB2T-63
10/1
16
NDB2T-63
16/1
20
NDB2T-63
20/1
25
NDB2T-63
25/1
32
NDB2T-63
32/1
40
NDB2T-63
40/1
50
NDB2T-63
50/1
63
NDB2T-63
63/1
16
NDM1-125 Series Miniature Circuit Breaker
Application
Number of Poles
1
B, C, D
2
1
5
3
B, C, D
3
4
5
7
B, C, D
17
4
6
54
6
4P
2
36
4
3P
2
Width (mm)
3
2P
1
Curve
8
72
Rated Current (A)
Part No.
Curve C: Usual inductive loads
1
NDB2T-63
1/2
Curve D: Highly inductive loads
2
NDB2T-63
2/2
Overload and short circuit protection
4
NDB2T-63
4/2
6
NDB2T-63
6/2
10
NDB2T-63
10/2
16
NDB2T-63
16/2
20
NDB2T-63
20/2
25
NDB2T-63
25/2
32
NDB2T-63
32/2
40
NDB2T-63
40/2
50
NDB2T-63
50/2
63
NDB2T-63
63/2
1
NDB2T-63
1/3
2
NDB2T-63
2/3
4
NDB2T-63
4/3
Rated current (A)
50, 63, 80, 100, 125
Number of poles
1, 2, 3, 4
Only Curve C available for 125A
Model and Implication
125
ND M 1
7
Implication
No.
NDM1-125
Brand code
Product code
M Miniature Circuit Breaker
Design code
1
Frame rating (A)
125
Instantaneous tripping characteristic
C, D
6
NDB2T-63
6/3
10
NDB2T-63
10/3
16
NDB2T-63
16/3
Standards and Certificates
20
NDB2T-63
20/3
UL1077, IEC 60947-2, GB 14048.2;
25
NDB2T-63
25/3
32
NDB2T-63
32/3
40
NDB2T-63
40/3
50
NDB2T-63
50/3
Ambient temperature: -35℃~+70℃
63
NDB2T-63
63/3
Air humidity: ≤95%
1
NDB2T-63
1/4
Altitude: ≤2000m
2
NDB2T-63
2/4
Pollution degree: Ⅲ
4
NDB2T-63
4/4
6
NDB2T-63
6/4
10
NDB2T-63
10/4
16
NDB2T-63
16/4
20
NDB2T-63
20/4
Modularized
25
NDB2T-63
25/4
Screw clamp, shock-proof wiring terminals
32
NDB2T-63
32/4
40
NDB2T-63
40/4
50
NDB2T-63
50/4
63
NDB2T-63
63/4
UL, TÜV, CE, DIN, CCC.
Working Condition
Specifications
Rated working voltage: AC230/400V, DC60V
Rated working current: 50A - 125A
Mechanical life: 10000 times
Rated impulse withstand voltage: 6kV
Tripping characteristic
C: 8In (±20%); D: 12In (±20%)
Breaking capacity:
Product Features
Rated current
(A)
Pole number
Voltage (V)
Breaking
capacity(kA)
50~125
1P
AC 230
10
50~125
2~4P
AC230/400
10
Numerous accessories available
Standard TH35mm DIN rail mounting
RoHS complied
Wiring capacity
≤50mm2
18
Dimension
NDB6-125 Series Miniature Circuit Breaker
Application
Short circuit protection
Overload protection
16.5
26.5
Control
Isolation
DC system protection
49.5
5.5
NDB6-125 series Miniature Circuit Breaker is used in low-voltage terminal distribution for industry, civil building,
energy, telecommunication, construction and so on.
Number of Poles
74.5max
Curve
C, D
1P
Width
(mm)
27
2
C
3
C, D
2P
54
4
C
1
3 5
C, D
3P
81
2 4 6
C
1
No.
3 5 7
C, D
4P
2 4 6
8
C
7
Implication
NDB6-125
Brand code
1
2
5 6
108max
4P
125
ND B 6
60
1P 27max
54max
2P
81max
3P
1
45
85max
Model and Implication
108
Rated Current
(A)
Part No.
50
NDM1-125
50/1
63
NDM1-125
63/1
80
NDM1-125
80/1
100
NDM1-125
100/1
125
NDM1-125
125/1
50
NDM1-125
50/2
63
NDM1-125
63/2
80
NDM1-125
80/2
100
NDM1-125
100/2
125
NDM1-125
125/2
50
NDM1-125
50/3
63
NDM1-125
63/3
80
NDM1-125
80/3
100
NDM1-125
100/3
125
NDM1-125
125/3
50
NDM1-125
50/4
63
NDM1-125
63/4
80
NDM1-125
80/4
100
NDM1-125
100/4
125
NDM1-125
125/4
Product code
B Miniature Circuit Breaker
Design code
6
Frame rating (A)
Instantaneous tripping
characteristic
Rated current (A)
125
63, 80, 100, 125*(Only Curve C is available for 125A)
Number of poles
1, 2, 3, 4
7
C, D
Standards and Certificates
IEC 60947-2, GB 14048.2;
TÜV, CE, DIN, CB and CCC.
Working Condition
Product Features
Ambient temperature :-35℃~+75℃
High breaking capacity
Air humidity: ≤95%
Modularized
Altitude: ≤2000m
Screw clamp, shock-proof wiring terminals
Pollution degree: Ⅲ
Standard TH35mm DIN rail mounting, II and III installation type
RoHS complied
Specifications
Wiring Capacity
Rated working voltage: AC230/400V,DC60V
Tunnel type terminal
Rated current : 63A, 80A, 100A, 125A
10mm2-50mm2 conducting wire
Mechanical life: 10000 times
Impulse voltage withstand: 6kV
Tripping characteristic:
C: 8In(1±20%); D: 12In(1±20%)
Breaking capacity: 15kA
19
20
Dimension
DC Application of NDM1 Series MCB
Rated current of NDM1 series MCB is decided by the power of DC control circuit
DC60V
One pole
DC125V
Two poles
DC250V
Four poles
f
g
a
According to DC rated voltage, there are several kinds of NDM1 series MCB cascade:
Revised feeding of line power is permitted
The estimated short circuit current can not exceed rated service short-circuit breaking capacity
d
c
e
Specification
b
DC rated service short-circuit breaking capacity (kA)
Rated Current (A)
60V
125V
250V
NDM1-63
1A~63A
10 (1P)
20 (2P)
50 (4P)
NDM1-125
50A~125A
20 (1P)
20 (2P)
15 (4P)
Dimension
Number
of Poles
amax
bmax
cmax
d
e
f
g
1P
27
Wiring Schematics
2P
54
+
- 60V
94
3P
85
46
75
45
+
- 125V
35.5±0.5
NDM1-63
NDM1-63
NDM1-63
NDM1-125
NDM1-125
NDM1-125
1P
81
Load
4P
+
- 250V
2P
Load
4P
Load
108
Package and Storage
Max. packing quantity: 9/box for 1P MCB, 4/box for 2P MCB, 3/box for 3P MCB, 2/box for 4P MCB.
12 boxes in an overwrap carton.
Please keep products away from snow and rain during transportation and storage. Products should
be stored in the warehouse where there is ventilation and with normal temperature and humidity. In
addition, there should not be significant shock or vibration.
21
22
Specifications
Working Condition
Ambient temperature: -35℃~+70℃
Pole number
Air humidity: ≤95%
1P
Altitude: ≤2000m
2P, 3P, 4P
Rated current
(A)
10kA
DC250V
DC220V
1~63A
2P, 3P, 4P
Breaking
capacity (kA)
DC125V
1~63A
1P
Pollution degree: Ⅱ
Voltage (V)
6kA
DC440V
Mechanical life: 20000 times
Product Features
Tripping characteristic: B: 4-7In; C: 7-15In
High breaking capacity
Modularized
Dimension
Visual indicator
Screw clamp, shock-proof wiring terminals
74max
Numerous accessories available
60
36max
Standard TH35mm DIN rail mounting
45
NDB2Z-63 Series DC Miniature Circuit Breaker
45
81.5
RoHS complied
21
Wiring Capacity
Application
≤35mm2
Curve B: DC non-inductive or micro-inductive loads
5.5
Curve C: DC usual inductive loads
Overload and short circuit protection
Model and Implication
ND B 2 Z
Number of Poles
Implication
8
1
NDB2Z-63
1P
B, C
Brand code
8
Width (mm)
63
7
No.
Curve
Product code
B Miniature Circuit Breaker
Design code
2
DC
Z
Frame rating (A)
63
Instantaneous tripping characteristic
B, C
Rated current (A)
1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles
1, 2
2
18
Rated Current (A)
Part No.
1
NDB2Z-63
1/1
2
NDB2Z-63
2/1
4
NDB2Z-63
4/1
6
NDB2Z-63
6/1
10
NDB2Z-63
10/1
16
NDB2Z-63
16/1
20
NDB2Z-63
20/1
25
NDB2Z-63
25/1
32
NDB2Z-63
32/1
40
NDB2Z-63
40/1
50
NDB2Z-63
50/1
63
NDB2Z-63
63/1
Standards and Certificates
UL1077, IEC60898-2, GB 10963.2;
UL1077, TÜV, CE and CCC.
23
24
Tripping Curves
Curve B (3~5In)
10000
5000
1h
2000
1000
500
10000
5000
1h
2000
1000
500
200
100
50
200
100
50
200
100
50
20
10
5
20
10
5
20
10
5
2
1
0.5
2
1
0.5
2
1
0.5
0.2
0.1
0.05
0.2
0.1
0.05
0.2
0.1
0.05
0.02
0.01
0.005
0.02
0.01
0.005
0.02
0.01
0.005
1
2
3 4 5 7 10
20 30 5070 100200 l/ln
NDM1-63, NDB2-63, NDB2LE-63
Width (mm)
Part No.
Rated Current (A)
NDB2Z-63
1
3
1
2P
36
4
2
NDB2Z-63
2/2
4
NDB2Z-63
4/2
6
NDB2Z-63
6/2
10
NDB2Z-63
10/2
16
NDB2Z-63
16/2
20
NDB2Z-63
20/2
25
NDB2Z-63
25/2
32
NDB2Z-63
32/2
40
NDB2Z-63
40/2
50
NDB2Z-63
50/2
63
NDB2Z-63
63/2
L-
+-
Load
1
+
2
-
+
-
1
2
L-
L-
M
L+
+
+
25
4
3
2
4
2
+
4
-
2
L+
3
+
4
-
+
-
L+
1) L+: Positive pole of power
L-: Negative pole of power
3
2 +
L+
4
2) + Positive pole of breaker
-Negative pole of breaker
3) Normally “L”grounds in DC power system
-
L-
M
L-
0.002
0.001
0.5
Curve C 8In (1±20%)
20
10
5
20
10
5
20
10
5
2
1
0.5
2
1
0.5
2
1
0.5
0.2
0.1
0.05
0.2
0.1
0.05
0.2
0.1
0.05
0.02
0.01
0.005
0.02
0.01
0.005
0.02
0.01
0.005
3 4 5 7 10
20 30 5070 100200 l/ln
0.002
0.001
0.5
1
2
3 4 5 7 10
20 30 5070 100200 l/ln
NDB2T-63, NDM1-125, NDB6-125
3 4 5 7 10
20 30 5070 100200 l/ln
Curve D 12In (1±20%)
200
100
50
2
2
NDM1-63, NDB2-63, NDB2LE-63
200
100
50
1
1
0.002
0.001
0.5
1
2
3 4 5 7 10
20 30 5070 100200 l/ln
NDB2T-63, NDM1-125, NDB6-125
Curve C (7~15In)
10000
5000
1h
2000
1000
500
10000
5000
1h
2000
1000
500
200
100
50
200
100
50
20
10
20
10
0.5
0.5
0.2
0.1
0.05
0.2
0.1
0.05
0.02
0.01
0.005
0.02
0.01
0.005
0.002
0.001
0.002
0.001
L-
Notes:
+
-
-
+
-
1
3
1
-
Bottom Leading-in
L+
-+
-+
1
2 +
4
Top Leading-in
L-
NDM1-63, NDB2-63, NDB2LE-63
NDB1-32, NDB1L(G)-32
Curve B (4~7In)
Bottom Leading-in
3
1
+
+1
3
L+
2P (D)
Top Leading-in
Bottom Leading-in
L+
20 30 5070 100200 l/ln
200
100
50
2P (C)
-+
Top Leading-in
3 4 5 7 10
10000
5000
1h
2000
1000
500
Wiring Schametics
Top Leading-in
2
10000
5000
1h
2000
1000
500
NDB2T-63
2P (B)
1
10000
5000
1h
2000
1000
500
0.002
0.001
0.5
For 3-pole and 4-pole NDB2Z-63 series MCB can be ordered upon special request.
1P (A)
0.002
0.001
0.5
Curve B 4In (1±20%)
1/2
2
Curve D (10~14In)
10000
5000
1h
2000
1000
500
0.002
0.001
0.5
Number of Poles
Curve C (5~10In)
while neutral line “M”grounds in AC power system.
0.5
1
2
3 4 5 7 10
20 30 5070 100200 l/ln
NDB2Z-63
0.5
1
2
3 4 5 7 10
20 30 5070 100200 l/ln
NDB2Z-63
26
Accessories for Miniature Circuit Breaker
OF Auxiliary Switch
Application
Linked to the left side of NDM1 series MCB, to indicate
the OPEN or CLOSED status of the associated breaker
Temperature Derating
Am ( ℃
rre
b )
cti mp ien
e
t
n
r
g
Ra
cu atur
te
rre
e
d
nt
( A curr
(A
en
)
)
t
Co
Specifications
11
te
-35
-30
-25
-20
-15
-10
-5
0
1
1.27
1.25
1.23
1.21
1.19
1.17
1.15
1.13
3
3.89
3.83
3.76
3.70
3.64
3.57
3.50
6
7.70
7.58
7.46
7.34
7.21
7.09
10
13.89
13.62
13.35
13.07
12.81
16
20.78
20.43
20.08
19.75
19.40
20
25.67
25.28
24.88
24.47
25
32.21
31.72
31.22
32
41.04
40.46
40
51.63
50
5
Voltage
Current
AC
230V
6A
AC
Voltage Current
400V
3A
DC
24V
6A
DC
48V
2A
DC
125V
1A
DC
250V
0.4A
10
15
1.10
1.08
1.06
Notes:
3.44
3.37
3.30
3.22
6.96
6.83
6.70
6.56
6.42
12.53
12.23
11.93
11.63
11.33
11.01
19.05
18.70
18.33
17.96
17.58
17.20
After clipping on to NDM1 series MCB,
Point 11 and 14 are connected when circuit is closed;
Point 11 and 12 are connected when circuit is open.
May be used in conjunction with a SD alarm switch or another
OF auxiliary switch.
24.06
23.64
23.22
22.78
22.34
21.89
21.43
30.70
30.18
29.65
29.10
28.55
27.98
27.41
26.82
39.82
39.17
38.51
37.84
37.15
36.47
35.75
35.03
34.30
50.86
50.04
40.21
48.37
47.51
46.63
45.74
44.83
43.90
42.95
64.92
63.97
62.92
61.86
60.77
59.67
58.54
57.40
56.23
55.05
53.81
63
83.48
82.06
80.64
79.19
77.72
76.22
74.70
73.14
71.54
69.91
68.24
80
135
130
126
122
118
115
112
108
104
99
95
Width (mm): 9
14
12
SD Alarm Switch
Application
Linked to the left side of NDM1 series MCB, to indicate
the tripping status of the associated breaker
Specifications
Voltage
Current
AC
230V
6A
AC
400V
3A
24V
6A
DC
48V
2A
125V
1A
DC
250V
0.4A
91
100
160
155
150
146
142
137
133
129
125
122
118
DC
125
275
265
255
245
235
225
215
205
195
185
175
DC
Voltage
Current
Width (mm): 9
92
Co
Am
m bie )
pe n
ng
Ra
ra t
tu
te
cu
re
d
rre
c
nt
( A urr
(A
en
)
)
t
rre
cti
te
Notes:
94
After clipping on to NDM1 series MCB,
Point 91 and 92 are connected when circuit is closed;
Point 91 and 94 are connected when the breaker trips due to fault;
Point 91 and 92 are connected when the breaker trips by manual
operation. Meanwhile, point 91 and 94 are disconnected.
May be used in conjunction with a OF auxiliary switch or another
SD alarm switch.
(℃
20
25
30
35
40
45
50
55
60
65
70
1
1.05
1.02
1.00
0.97
0.94
0.91
0.89
0.86
0.83
0.80
0.77
3
3.14
3.06
3.00
2.92
2.84
2.76
2.67
2.58
2.49
2.38
2.27
6
6.27
6.14
6.00
5.84
5.68
5.52
5.36
5.19
5.01
4.83
4.64
10
10.67
10.34
10.00
9.63
9.24
8.85
8.45
8.01
7.55
7.06
6.55
16
16.80
16.40
16.00
15.55
15.11
14.66
14.20
13.71
13.21
12.70
12.75
20
20.96
20.47
20.00
19.47
18.95
18.42
17.87
17.30
16.71
16.10
15.47
25
26.22
25.61
25.00
24.33
23.67
23.00
22.28
21.56
20.80
20.02
19.21
Control voltage
Width (mm): 18
32
33.54
32.77
32.00
31.17
30.34
29.48
28.60
27.69
26.75
25.78
24.77
40
41.98
40.99
40.00
38.93
37.85
36.75
35.61
34.43
33.21
31.95
30.63
50
52.56
51.28
50.00
47.82
46.24
44.81
43.33
41.81
40.23
38.58
35.77
63
66.53
64.78
63.00
60.11
58.19
56.21
54.16
52.03
49.81
47.50
43.05
80
91
88
85
82
80
75.5
72.5
68
64.5
58
52.5
100
114
111
108
103
100
94
88
82
75
68
58
125
165
155
145
135
125
115
105
95
85
75
65
MX+OF Shunt Release
Application
Linked to the right side of NDM1 series MCB.
L or +
Specifications
12
14
MCB open
N or - L1
SB
Wiring Capacity
mounted. For breakers below 63A, the reference number is 30℃, while 40℃ for breakers from 80A to 125A.
Single line: 2.5mm2
DC 24V/48V
Active transfer contact
ZJ
L2
Double line: 1.5mm2
MX+OF K
ZJ
Standards and Certificates
Note: Ambient temperature refers to the temperature inside the distribution board or switchgear where breakers are
AC 230V/400V
MCB closed
IEC 60947-5, GB 14048.5;
TÜV, CE, CCC.
27
Remote control
C1
C2
DC24V
A1 A2
Power input
Note: At DC24V, above design of shunt control circuit is
recommended
ZJ: DC24V intermediate relay
28
OF2 Auxiliary Switch
MX+OF2 Shunt Release
Application
Linked to the left side of NDB2 series MCB for remote
11
tripping of the breaker.
Indicating tripping status of the associated breaker
u>
Specifications
14 12
14
12
MCB closed
C2
MCB open
Control voltage
C1
SB
L or +
N or -
Application
Linked to the left side of NDB2 series MCB, to indicate the OPEN or CLOSED
status of the associated breaker
Voltage
Current
Voltage
Current
AC
415V
3A
AC
240V
6A
DC
130V
1A
DC
48V
2A
DC
24V
6A
DC 24V/48V
Width (mm): 18
Active transfer contact
ZJ
MX+OF2 K
Note: At DC24V, above design of shunt control circuit is
ZJ
recommended
Specifications
AC 230V/400V
ZJ: DC24V intermediate relay
DC24V
A1 A2
Power input
Wiring Capacity
Single line: 2.5mm2
Width (mm): 9
Notes: After clipping on to NDB2 series MCB,
Double line: 1.5mm2
Point 11 and 14 are connected when circuit is closed;
Point 11 and 12 are connected when circuit is open.
May be used in conjunction with a SD2 alarm switch or another OF2 auxiliary switch.
NDH1 Series Busbar
SD2 Alarm Switch
Application
Application
Linked to the left side of NDB2 series MCB, to
indicate the tripping status of the associated breaker
NDH1 series busbar is accessory of NDM1-63, NDB2-63, NDG1 products. It is used to link product line terminals of the
same phase. It can also be used to link terminal apparatus in the same way.
Specifications
91
92
94
Voltage
Current
AC
415V
3A
DC
130V
1A
DC
24V
6A
Voltage
Current
AC
240V
6A
DC
48V
2A
Model and Implication
ND H 1
Width (mm): 9
Notes: After clipping on to NDM1 series MCB,
Point 91 and 92 are connected when circuit is closed;
Point 91 and 94 are connected when the breaker trips due to fault;
Point 91 and 92 are connected when the breaker trips by manual
operation. Meanwhile, point 91 and 94 are disconnected.
May be used in conjunction with a OF2 auxiliary switch or another
SD2 alarm switch.
Standards and Certificates
IEC 60947-5, GB 14048.5;
TÜV, CE, CCC.
No.
Implication
NDH1
Brand code
Product code
H Busbar
Design code
1
Frame rating (A)
63, 100
Number of p ooles
1P, 2P, 3P
Width (mm)
Wiring Capacity
Single line: 2.5mm2
29
Double line: 1.5mm2
30
NDH2 Series Busbar
Application
NDH2-63 series busbar is accessory of NDM1-63 and NDB2-63 series MCB. It is used to link MCB line terminals of the same
phase. It can also be used to link terminal apparatus in the same way.
Model and Implication
ND H 2
No.
63
Implication
NDH2
Brand code
Product code
Product Features
H Busbar
Design code
2
Frame rating (A)
63
Number of poles
1P, 3P
Width (mm)
Consist of comb copper bar and insulated cover.
Use T2 pure copper plate for copper bar and enhanced flame retardant PVC for insulated cover.
Compact and simple usage.
IP20 Protection degree
Product Features
Consist of comb copper bar and insulated cover.
Use T2 pure copper plate for copper bar and enhanced flame retardant PVC for insulated cover.
Compact and simple usage.
Product Type
By pole number: 1-Pole, 2-Pole, 3-Pole
IP20 Protection degree
Product Type
By length: Multiple of 18mm, also can be customized, and 60 kits at most (1080 mm).
By kit number: the poles that are linked.
By pole number: 1-Pole, 3-Pole
By length: Multiple of 18mm, also can be customized, and 60 kits at most (1080 mm).
By kit number: the poles that are linked.
Specification
Rated insulation voltage: 500V
Specification
Rated current: up to 100A
Rated insulation voltage: 500V
Conventional thermal current: 100A
Impulse voltage withstand: 6kV
Rated current: up to 63A
Conventional thermal current: 63A
Impulse voltage withstand: 6kV
Short-time withstand current: 25kA/0.5s
Power frequency voltage withstand: 2500V (AC 50Hz); No breakdown and flashover within 1 minutes.
31
Short-time withstand current: 25kA/0.5s
Power frequency voltage withstand: 2500V (AC 50Hz); No breakdown and flashover within 1 minutes
32
Number of Poles
Width (mm)
NDG1 Series Disconnect Swtich
Application
Rated Current (A)
Part No.
18
32
NDG1-100
32/1
18
63
NDG1-100
63/1
18
100
NDG1-100
100/1
36
32
NDG1-100
32/2
36
63
NDG1-100
63/2
36
100
NDG1-100
100/2
54
32
NDG1-100
32/3
54
63
NDG1-100
63/3
54
100
NDG1-100
100/3
72
32
NDG1-100
32/4
72
63
NDG1-100
63/4
72
100
NDG1-100
100/4
Close, open or disconnect the circuit
Model and Implication
ND G 1
100
Implication
No.
NDG1-100
Brand code
Product code
G Disconnect Switch
Design code
1
Frame rating (A)
100
Rated current (A)
32, 63, 100
Number of poles
1, 2, 3, 4
Standards and Certificates
IEC 60947-3, GB 14048.3; TÜV, CE, CCC.
OF3 Auxiliary Switch
Application
Linked to the left side of NDG1-100 series disconnect
switch to indicate the OPEN or CLOSED status
Specifications
Rated working voltage: AC230/400V
Mechanical life: 10000 times
Working Condition
Ambient temperature: -35℃~+70℃
Air humidity: ≤95%
Altitude: ≤2000m
Pollution degree: Ⅱ
Wiring Capacity
>4mm2 , ≤50 mm2 (Minimum 4mm2 for BV)
33
35
Specification
11
14
Rated short-time withstand current
2000A
(400V, 1s)
6A
AC 415V
3A
Width (mm): 18
Note: Clip onto NDG1-100 series disconnect switch.
Switching capacity:
3InA
(400V, cos=0.65)
Rated short current making capacity:
2000A
(400V, cos=0.9)
12
AC 250V
Point 11 and 14 is connected when circuit is closed;
Point 11 and 12 is connected when circuit is opened.
Wiring Capacity
≤10mm 2
Standards and Certificates
IEC 60947-5, GB 14048.5;
TÜV, CE, CCC.
34
Product Overview of Residual Current Protective Devices
Product name
Residual Current Unit
Product range
Product Overview of Residual Current Protective Devices
Residual Current Unit
Product name
RCBO
RCBO
RCBO
RCBO
RCCB
NDM1LG-32, NDM1LG-50
Product range
NDB1L-32
NDB1LG-32
NDB2LE-63
NDB6LM-40
NDL6M-100
IEC 61009-1
IEC 61009-1
IEC 61009-1
IEC 61009-1
IEC 61008-1
1P+N
1P+N
Rated current(A) In
6~32
6~32
AC230V/400V
Rated voltage(V) Ue
AC230V
AC230V
30, 100 (6, 10 can
be customized)
30 (6, 10, 100 can
be customized)
Rated residual current(mA)
——
——
——
Breaking capacity (kA)
Without
Without
With
Overvoltage protection function
NDM1L-32, NDM1L-50
NDM1L-100
Product picture
Product picture
IEC 61009-1
Standard
Number of poles
1P+N, 2P
IEC 60947-2
3P, 3P+N, 4P 1P+N, 2P
3P, 3P+N, 4P
IEC 61009-1
1P+N, 2P
Electrical characteristics
AC230V,
AC400V
Rated residual current(mA)
Breaking capacity (kA)
Overvoltage protection function
AC400V
30 (6, 10, 100 can
be customized)
AC230V,
AC400V
AC400V
Tripping curve
Tripping curve
Residual current
operating characteristic
Residual current
protection mode
2
Connection capacity (mm )
37
35
Number of poles
1P+N, 2P 3P, 3P+N, 4P
1P+N
2
4
Electrical characteristics
Rated current(A) In
Rated voltage(V) Ue
Standard
AC
AC
AC
Electronic
Electronic
Electronic
NDM1LG-32: 10;
NDM1LG-50: 25.
50
NDM1LG-32: 10;
NDM1LG-50: 25.
Residual current
operating characteristic
Residual current
protection mode
2
Connection capacity (mm )
30 (6, 10, 100 can 30 (6, 10, 100 can
be customized)
be customized)
1~63
AC230V
AC400V
30 (6, 10, 100 can
be customized)
AC230V
16~100
AC230V,
AC230V AC400V
30, 100, 300
30, 100, 300
6~40
4.5
4.5
6
10
10
Without
With
Without
Without
Without
C
C
B, C, D
B, C
——
AC
AC
AC
A, AC
A, AC
Electronic
Electronic
Electronic
Electromagnetic
Electromagnetic
10
10
35
35
35
36
Working Condition
Dimension
Ambient temperature: -5℃ ~+40℃
Air humidity: ≤95%
60
Altitude: ≤2000m
40
5.5
L
Specifications
45
94max
Pollution degree: Ⅱ
Rated working voltage: AC230/400V (1PN, 2P)
AC400V (3P, 3PN, 4P)
Rated residual operating current: 30mA, 100mA
69.5max
Release type: AC, electronic
NDM1L-32, 50
Wiring Capacity
NDM1L-100
NDM1L-32: ≤ 10mm2
NDM1L Series Residual Current Unit
NDM1L-50: ≤ 25mm2
Application
NDM1L-100: ≤ 50mm2
Clip onto the right side of NDM1 series MCB
Protection against earth leakage faults
NDM1L-32 (50) Residual Current Unit
Model and Implication
ND M 1 L
N
27
30
32
NDM1L-32/1PN
37
30
50
NDM1L-50/1PN
27
30
32
NDM1L-32/2
37
30
50
NDM1L-50/2
36
30
32
NDM1L-32/3
51
30
50
NDM1L-50/3
45
30
32
NDM1L-32/3PN
64
30
50
NDM1L-50/3PN
45
30
32
NDM1L-32/4
64
30
50
NDM1L-50/4
Part No.
1PN
6 7
Implication
2
NDM1L
Brand code
1
N
3
2P
Product code
M Miniature Circuit Breaker
Design code
1
Residual current protection
L
Frame rating (A)
32, 50, 100
Number of poles
1PN, 2P, 3P, 3PN, 4P
Rated residual operating current (mA)
30, 100
2 4
1 3
5
3P
2 4 6
3PN
1
3 5
1 3 5 N
Standards and Certificates
NDM1L-32, NDM1L-50: IEC 61009-1, GB 16917.1; CCC.
NDM1L-100: IEC60947-2, GB14048.2; CCC.
1
3
5
7
4P
2
37
Frame Rating
(A)
1
5
No.
Rated Residual
Operating Current (mA)
Width (mm)
Number of Poles
4 5 8
38
NDM1LG Series Overvoltage Protection Residual Current Unit
Application
Clip onto the right side of NDM1-63 series MCB
Protection against earth leakage faults and overvoltage
Model and Implication
ND M 1 L G
7 8
Implication
No.
NDM1LG
Brand code
Product code
M Miniature Circuit Breaker
Design code
1
Residual current protection
L
Over voltage protection
G
Frame rating (A)
32, 50
Number of poles
1PN, 2P
Rated residual operating current (mA)
30
NDM1L-100 Series Residual Current Unit
Number of Poles
Frame Rating
Rated Residual
Width
(A)
(mm) Operating Current (mA)
Part No.
8
Standards and Certificates
54
1PN
30, 100
100
NDM1L-100/1PN
IEC 61009-1, GB 16917.1; CCC
Working Condition
1
Dimension
3
54
2P
30, 100
100
NDM1L-100/2
2 4
Ambient temperature: -5℃ ~+40℃
Air humidity: ≤95%
73
30, 100
100
NDM1L-100/3
Pollution degree: Ⅱ
Specifications
3PN
90
30, 100
100
NDM1L-100/3PN
Rated working voltage: AC230/400V(1PN, 2P)
L
5.5
45
3P
60
40
94max
Altitude: ≤2000m
Over voltage limits: AC280V±5%
Release type: AC, electronic
4P
90
30, 100
100
NDM1L-100/4
69.5max
Wiring Capacity
Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.
Release should be released before MCB dielectric test.
Release should be used and ordered together with Nader MCB.
39
NDM1LG-32, 50
NDM1LG-32: ≤10mm2
NDM1LG-50: ≤25mm2
40
NDB1L Series RCBO (1P+N)
Application
TT/TN-S grounding system
Phase and neutral protection against short circuit, overload and earth leakage
Model and Implication
ND B 1 L
32 C
7
Implication
No.
NDB1L-32
Brand code
NDM1LG-32 (50) Series Overvoltage Protection Residual Current Unit
Number of Poles
N
Rated Residual
Frame Rating
Width (mm)
Operating Current (mA)
(A)
27
30
32
Product code
B Miniature Circuit Breaker
Design code
1
Residual current protection
L
Frame rating
32
Instantaneous tripping characteristic
C
Rated current (A)
6, 10, 16, 20, 25, 32
Part No.
NDM1LG-32/1PN
Standards and Certificates
1
1PN
2
N
37
30
50
NDM1LG-50/1PN
UL1053, IEC61009-1, GB16917.1;
UL1053, TÜV, CE and CCC.
27
1
30
32
NDM1LG-32/2
3
Wiring Capacity
Working Condition
2P
2 4
37
30
50
NDM1LG-50/2
≤10mm2
Ambient temperature: -5℃~+40℃
Air humidity: ≤95%
Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.
Release should be released before MCB dielectric test
Release should be used and ordered together with Nader MCB.
Altitude: ≤2000m
Dimension
Pollution degree: Ⅱ
68.5
Match Principle
Product Features
Frame rating
1P
1PN
Phase and neutral are both switched when circuit opens
2P
2P
or trips because of failure
3P
3P, 3PN
Neutral line connected early and disconnected late
4P
4P
Screw clamp, shock-proof wiring terminals
NDM1-63
NDM1-125
41
NDM1L (G)-32 (1A-32A)
NDM1L (G)-50 (40A , 50A)
NDM1L-100 (50A , 63A , 80A , 100A)
5.5
LINE N
进线端
T
78max
Number of poles
NDM1L Series Residual Current Unit
45
NDM1 Series MCB
36max
40
Standard TH35mm DIN rail mounting
LOAD
出线端 N
RoHS complied
70.3max
42
NDB1LG Series RCBO with Overvoltage Protection (1P+N)
Application
TT/TN-S grounding system
Phase and neutral protection against short circuit, overload, earth leakage and overvoltage
Model and Implication
ND B 1 L G
32 C
5
6
7 8
Implication
No.
NDB1LG-32
Brand code
Specifications
Product code
B Miniature Circuit Breaker
Design code
1
Residual current protection
L
Overvoltage protection
G
Frame rating (A)
32
Instantaneous tripping characteristic
C
Rated current (A)
6, 10, 16, 20, 25, 32
8
Rated working voltage: AC230
Mechanical life: 10000 times
Tripping characteristic: C: 5-10In
Standards and Certificates
Rated residual operating current: 30mA
IEC 61009-1, GB 16917.1; CCC.
Breaking capacity: 4.5kA
Release type: AC, electronic type
Working Condition
Wiring Capacity
≤10mm2
Ambient temperature: -5℃~+40℃
Width (mm)
1P+N
C
36
Rated Current
Rated Residual
(A)
Operating Current (mA)
Air humidity: ≤95%
Part No.
Altitude: ≤2000m
6
NDB1L-32
6
10
NDB1L-32
10
NDB1L-32
16
20
NDB1L-32
20
25
NDB1L-32
25
32
NDB1L-32
32
16
30
Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.
68.5
36max
40
Product Features
5.5
or trips because of failure
LINE N
进线端
T
Phase and neutral are both switched when circuit opens
Neutral line connected early and disconnected late
Screw clamp, shock-proof wiring terminals
LOAD
出线端 N
Standard TH35mm DIN rail mounting
RoHS complied
43
Dimension
Pollution degree: Ⅱ
78max
Curve
45
Number of Poles
70.3max
44
NDB2LE Series Residual Current Circuit Breaker with Overload Protection
Application
Protection against short circuit, overload and earth leakage
Model and Implication
ND B 2 L E
63
7 8
9
NDB2LE
Implication
No.
Brand code
B Miniature Circuit Breaker
Design code
2
Residual current release
L
Electronic type
E
Frame rating (A)
63
Instantaneous tripping characteristic
B, C, D
Rated current (A)
1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles
1PN, 2P, 3P, 3PN, 4P
8
9
Specifications
Product code
Rated working voltage: AC230
Standards and Certificates
Mechanical life: 10000 times
Tripping characteristic: C: 5-10In
IEC 61009-1, GB 16917.1;
Rated residual operating current: 30mA
TÜV, CE, CCC.
Breaking capacity: 4.5kA
Overvoltage: AC280V±5%
Specifications
Working Condition
Release type: AC, electronic type
Rated working voltage: AC230V (1PN, 2P)
Ambient temperature: -5℃~+40℃
Number of Poles
Curve Width (mm)
1P+N
C
36
Rated Current
Rated Residual
(A)
Operating Current (A)
Part No.
Air humidity: ≤95%
Altitude: ≤2000m
Release type: AC, electronic
6
NDB1LG-32
6
Pollution degree: Ⅱ
10
NDB1LG-32
10
RoHS complied
NDB1LG-32
16
20
NDB1LG-32
20
25
NDB1LG-32
25
32
NDB1LG-32
32
16
30
AC400V (3P, 3PN, 4P)
Rated residual operating current: 30mA
(6mA, 10mA, 100mA, 300mA can be customized)
Wiring Capacity
≤35mm2
Dimension
1PN, 2P
72
54
2P
1PN
75
60
45
45
45
90.5
Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.
46
Dimension
Number of Poles
Curve
Width (mm)
3P, 3PN, 4P
75
3PN, 4P
117
60
45
45
3P
B, C, D
90.5
135
117
3P
1
3
5
2 4 6
Number of Poles
Curve
B, C, D
Width
(mm)
54
1PN
N
1
N 2
B, C, D
2P
1
3
2 4
72
Rated Current
(A)
Part No.
Rated Current
(A)
Part No.
1
NDB2LE-63
1/3
2
NDB2LE-63
2/3
4
NDB2LE-63
4/3
6
NDB2LE-63
6/3
10
NDB2LE-63
10/3
16
NDB2LE-63
16/3
20
NDB2LE-63
20/3
25
NDB2LE-63
25/3
32
NDB2LE-63
32/3
40
NDB2LE-63
40/3
50
NDB2LE-63
50/3
63
NDB2LE-63
63/3
1
NDB2LE-63
1/3PN
2
NDB2LE-63
2/3PN
4
NDB2LE-63
4/3PN
6
NDB2LE-63
6/3PN
10
NDB2LE-63
10/3PN
16
NDB2LE-63
16/3PN
20
NDB2LE-63
20/3PN
25
NDB2LE-63
25/3PN
32
NDB2LE-63
32/3PN
40
NDB2LE-63
40/3PN
50
NDB2LE-63
50/3PN
63
NDB2LE-63
63/3PN
1
NDB2LE-63
1/4
1
NDB2LE-63
1/1PN
2
NDB2LE-63
2/1PN
4
NDB2LE-63
4/1PN
6
NDB2LE-63
6/1PN
10
NDB2LE-63
10/1PN
16
NDB2LE-63
16/1PN
20
NDB2LE-63
20/1PN
25
NDB2LE-63
25/1PN
32
NDB2LE-63
32/1PN
40
NDB2LE-63
40/1PN
50
NDB2LE-63
50/1PN
63
NDB2LE-63
63/1PN
2
NDB2LE-63
2/4
1
NDB2LE-63
1/2
4
NDB2LE-63
4/4
2
NDB2LE-63
2/2
4
NDB2LE-63
4/2
6
NDB2LE-63
6/4
6
NDB2LE-63
6/2
10
NDB2LE-63
10/4
10
NDB2LE-63
10/2
16
NDB2LE-63
16/4
16
NDB2LE-63
16/2
20
NDB2LE-63
20/4
20
NDB2LE-63
20/2
25
NDB2LE-63
25/2
25
NDB2LE-63
25/4
32
NDB2LE-63
32/2
32
NDB2LE-63
32/4
40
NDB2LE-63
40/2
40
NDB2LE-63
40/4
50
NDB2LE-63
50/2
50
NDB2LE-63
50/4
63
NDB2LE-63
63/2
63
NDB2LE-63
63/4
B, C, D
135
3PN
N 1 3
5
N2 46
B, C, D
4P
1
3 5 7
2 4 68
135
Release should be released first during MCB dielectric test
NDB2LE-63 3PN can be ordered upon special request
47
48
Standards and Certificates
Wiring capacity
Conducting wire: 1~25mm2
Thickness of busbar: 0.8~2mm
GB16917.1, IEC 61009-1
TÜV , CE, CCC.
Dimension
Working Condition
Ambient temperature: -25℃~+40℃
60
44
Relative air humidity: ≤95%
5.5
Altitude: ≤2000m
Pollution Degree: II
45
89
81
External magnetic field should be 5 times smaller than
geomagnetic field.
Product Features
Residual current operating function is independent of
main circuit voltage, more reliable.
13
When the breaker is in the position OFF for failure
protection or by normal operation, both phase line and
neutral line are in the state OFF avoiding injured by
neutral connected.
NDB6LM Series RCBO
During the operations, the neutral line makes first and
then breaking lags.
Application
Terminal with double function, connection easily and
reliability.
TT/TN-S grounding system
Standard TH35mm DIN rail mounting.
36
30
18
3.5
9
RoHS complied.
Protection against overload, short circuit and earth leakage
Specifications
Model and Implication
Rated working voltage: AC230V
ND B 6 L M
5
No.
40
6
Implication
Tripping characteristics:
7 8
9
10
C: 5-10 In
11
Rated residual operating current: 0.030A, 0.100A, 0.300A
Breaking capacity: 10kA
Residual current operating characteristic: A, AC
NDB6LM-40
Brand
Brand code
7
B: 3-5 In
Mechanical life: 20000 times
Product code
B Breaker
Design code
6
Protection against residual
current (earth leakage protection)
L
Electromagnetic type
M
Frame rating (A)
40
Instantaneous tripping
characteristic
B, C
8
9
Rated current (A)
6, 10, 16, 20, 25, 32, 40
Number of poles
1P+N
10
Rated residual operating
current (A)
0.030, 0.100, 0.300
11
Residual current operating
characteristic
A, AC
Number of Poles
Curve
Width
(mm)
Rated Current
(A)
Rated Residual Residual Current
Operating
Operating
Current (A) Characteristics
Part No.
NDB6LM-40 B6/1P+N/0.030/A
NDB6LM-40 B6/1P+N/0.100/A
NDB6LM-40 B6/1P+N/0.300/A
1P+N
NDB6LM-40 B6/1P+N/0.030/AC
0.030
B, C
36
6
0.100
0.300
NDB6LM-40 B6/1P+N/0.100/AC
A
NDB6LM-40 B6/1P+N/0.300/AC
AC
NDB6LM-40 C6/1P+N/0.030/A
NDB6LM-40 C6/1P+N/0.100/A
NDB6LM-40 C6/1P+N/0.300/A
NDB6LM-40 C6/1P+N/0.030/AC
NDB6LM-40 C6/1P+N/0.100/AC
NDB6LM-40 C6/1P+N/0.300/AC
49
50
Number of Poles
Curve
Width
(mm)
Rated Current
(A)
Rated Residual Residual Current
Operating
Operating
Current (A) Characteristics
Part No.
NDB6LM-40 B20/1P+N/0.030/A
NDB6LM-40 B20/1P+N/0.100/A
NDB6LM-40 B20/1P+N/0.300/A
NDB6LM-40 B20/1P+N/0.030/AC
NDB6LM-40 B20/1P+N/0.100/AC
NDB6LM-40 B20/1P+N/0.300/AC
20
NDB6LM-40 C20/1P+N/0.030/A
NDB6LM-40 C20/1P+N/0.100/A
NDB6LM-40 C20/1P+N/0.300/A
NDB6LM-40 C20/1P+N/0.030/AC
NDB6LM-40 C20/1P+N/0.100/AC
NDB6LM-40 C20/1P+N/0.300/AC
NDB6LM-40 B25/1P+N/0.030/A
NDB6LM-40 B25/1P+N/0.100/A
NDB6LM-40 B25/1P+N/0.300/A
NDB6LM-40 B25/1P+N/0.030/AC
NDB6LM-40 B25/1P+N/0.100/AC
Number of Poles
Rated Rated Residual Residual Current
Width
Curve
Current Operating
Operating
(mm)
Current (A) Characteristics
(A)
NDB6LM-40 B25/1P+N/0.300/AC
25
Part No.
NDB6LM-40 C25/1P+N/0.030/A
NDB6LM-40 C25/1P+N/0.100/A
NDB6LM-40 B10/1P+N/0.030/A
NDB6LM-40 B10/1P+N/0.100/A
NDB6LM-40 C25/1P+N/0.300/A
1P+N
NDB6LM-40 C25/1P+N/0.030/AC
NDB6LM-40 B10/1P+N/0.300/A
NDB6LM-40 B10/1P+N/0.030/AC
NDB6LM-40 B10/1P+N/0.100/AC
0.030
B, C
36
0.100
0.300
NDB6LM-40 B10/1P+N/0.300/AC
10
NDB6LM-40 C10/1P+N/0.030/A
B, C
36
0.100
0.300
32
NDB6LM-40 B32/1P+N/0.100/A
NDB6LM-40 B32/1P+N/0.300/AC
NDB6LM-40 C32/1P+N/0.030/A
A
NDB6LM-40 C10/1P+N/0.300/AC
NDB6LM-40 C32/1P+N/0.100/A
AC
NDB6LM-40 B16/1P+N/0.030/A
NDB6LM-40 C32/1P+N/0.300/A
NDB6LM-40 B16/1P+N/0.100/A
NDB6LM-40 C32/1P+N/0.030/AC
NDB6LM-40 B16/1P+N/0.300/A
NDB6LM-40 C32/1P+N/0.100/AC
NDB6LM-40 B16/1P+N/0.030/AC
NDB6LM-40 C32/1P+N/0.300/AC
NDB6LM-40 B40/1P+N/0.030/A
NDB6LM-40 B16/1P+N/0.100/AC
16
NDB6LM-40 B32/1P+N/0.030/A
NDB6LM-40 B32/1P+N/0.100/AC
NDB6LM-40 C10/1P+N/0.030/AC
0.030
AC
NDB6LM-40 B32/1P+N/0.030/AC
NDB6LM-40 C10/1P+N/0.300/A
NDB6LM-40 C10/1P+N/0.100/AC
NDB6LM-40 C25/1P+N/0.300/AC
NDB6LM-40 B32/1P+N/0.300/A
NDB6LM-40 C10/1P+N/0.100/A
1P+N
NDB6LM-40 C25/1P+N/0.100/AC
A
NDB6LM-40 B40/1P+N/0.100/A
NDB6LM-40 B16/1P+N/0.300/AC
NDB6LM-40 B40/1P+N/0.300/A
NDB6LM-40 C16/1P+N/0.030/A
NDB6LM-40 B40/1P+N/0.030/AC
NDB6LM-40 C16/1P+N/0.100/A
NDB6LM-40 B40/1P+N/0.100/AC
NDB6LM-40 C16/1P+N/0.300/A
NDB6LM-40 C16/1P+N/0.030/AC
NDB6LM-40 C16/1P+N/0.100/AC
NDB6LM-40 C16/1P+N/0.300/AC
40
NDB6LM-40 B40/1P+N/0.300/AC
NDB6LM-40 C40/1P+N/0.030/A
NDB6LM-40 C40/1P+N/0.100/A
NDB6LM-40 C40/1P+N/0.300/A
NDB6LM-40 C40/1P+N/0.030/AC
NDB6LM-40 C40/1P+N/0.100/AC
NDB6LM-40 C40/1P+N/0.300/AC
51
52
Wiring Capacity
Standards and Certificates
Tunnel terminal
Cables up to 35mm2. Can be connected using busbar
and 35mm2 cable at the same time.
GB16916.1, IEC 61008-1
TÜV , CE and CCC certificates.
Product Features
AC type: protection against the effects of residual
sinusoidal alternating currents, whether suddenly
applied or slowly rising.
Working Condition
A type: protection against the effects of residual
sinusoidal alternating currents and residual pulsating
direct currents, whether suddenly applied or slowly rising.
Residual current operating function is independent of
main circuit voltage, more reliable.
When the breaker is in the position OFF for failure
protection or by normal operation, both phase line
and neutral line are in the state OFF avoiding injured
by neutral connected.
During the operations, neutral line makes first and
then breaking lags.
Ambient temperature: -25℃~+55℃
Relative air humidity: ≤95%
Altitude: ≤2000m
Pollution Degree: II
External magnetic field should be 5 times smaller than
geomagnetic field.
Specifications
Besides detecting residual current, the product can
make, break or isolate the whole circuit without
overload or short-circuit protection, so it should be
used together with circuit breaker upstream.
Rated working voltage: AC230V (2P), AC230/400V (4P)
Rated frequency: 50Hz
NDL6M-100 Series RCCB
With isolation function.
Mechanical life: 20000 times
Application
High anti-interference ability.
Rated residual operating cureent: 30mA, 100mA, 300mA
Standard Th35mm DIN rail mounting.
Rated conditional short-circuit current Inc: 10kA
RoHS complied.
Residual current operating characteristic: A, AC
TT/TN-S grounding system
Protection against residual current
Dimension
2P RCCB
Model and Implication
100
8
9
NDL6M
Brand code
53
Brand
Protection against residual
current (earth leakage protection)
L
Design code
6
Electromagnetic type
M
2.8
Frame rating (A)
100
Rated current (A)
16, 25, 40, 63, 80, 100
7
Number of poles
2, 4
8
Rated residual operating
current (mA)
30, 100, 300
9
Residual current operating
characteristic
A, AC
45±0.2
Implication
7
31±0.3
35.5±0.2
No.
6
44±0.3
18±0.3
85±0.4
5
5.5 ±0.2
36 Max.
80.1±0.3
ND L 6 M
60±0.3
10.5
12±0.2
54
Residual Current
Rated Residual
Width Rated Current
Operating
Operating
(A)
Characteristics (mm)
Current (mA)
Number of Poles
2P
63
1
N
AC type
36
80
T
2
N
100
16
4P
25
1
3
N
5
40
Dimension
AC type
70
T
4P RCCB
63
2
60 ±0.2
72 Max.
5.5 ±0.2
31 ±0.3
44 ±0.2
4
N
2.8
18 ±0.3
45 ±0.2
35.5 ±0.2
85 ±0.4
80.1 ±0.3
80
100
12 ±0.2
2P
10.5
1
16
N
A type
36
25
T
Number of Poles
Residual Current
Operating
Characteristics
Rated Residual
Width Rated Current
Operating
(A)
(mm)
Current (mA)
2P
1
16
N
AC type
36
25
T
2
N
40
55
Part No.
2
N
40
30
NDL6M-100 16/2/30/AC
100
NDL6M-100 16/2/100/AC
300
NDL6M-100 16/2/300/AC
30
NDL6M-100 25/2/30/AC
100
NDL6M-100 25/2/100/AC
300
NDL6M-100 25/2/300/AC
30
NDL6M-100 40/2/30/AC
100
NDL6M-100 40/2/100/AC
300
NDL6M-100 40/2/300/AC
Part No.
30
NDL6M-100 63/2/30/AC
100
NDL6M-100 63/2/100/AC
300
NDL6M-100 63/2/300/AC
30
NDL6M-100 80/2/30/AC
100
NDL6M-100 80/2/100/AC
300
NDL6M-100 80/2/300/AC
30
NDL6M-100 100/2/30/AC
100
NDL6M-100 100/2/100/AC
300
NDL6M-100 100/2/300/AC
30
NDL6M-100 16/4/30/AC
100
NDL6M-100 16/4/100/AC
300
NDL6M-100 16/4/300/AC
30
NDL6M-100 25/4/30/AC
100
NDL6M-100 25/4/100/AC
300
NDL6M-100 25/4/300/AC
30
NDL6M-100 40/4/30/AC
100
NDL6M-100 40/4/100/AC
300
NDL6M-100 40/4/300/AC
30
NDL6M-100 63/4/30/AC
100
NDL6M-100 63/4/100/AC
300
NDL6M-100 63/4/300/AC
30
NDL6M-100 80/4/30/AC
100
NDL6M-100 80/4/100/AC
300
NDL6M-100 80/4/300/AC
30
NDL6M-100 100/4/30/AC
100
NDL6M-100 100/4/100/AC
300
NDL6M-100 100/4/300/AC
30
NDL6M-100 16/2/30/A
100
NDL6M-100 16/2/100/A
300
NDL6M-100 16/2/300/A
30
NDL6M-100 25/2/30/A
100
NDL6M-100 25/2/100/A
300
NDL6M-100 25/2/300/A
30
NDL6M-100 40/2/30/A
100
NDL6M-100 40/2/100/A
300
NDL6M-100 40/2/300/A
56
NDA1 Series Modular Socket
Model and Implication
ND A 1
NDA1
Implication
No.
Brand code
A Modular Socket
Product code
Design code
1
Rated current (A)
10, 16, 25
Number of holes
2, 3, 4
Width modular
2, 4, 6, 8
Rated current
10A
Number of Holes
2
25A
16A
2: Single phase, two holes
Residual Current
Rated Residual
Width Rated Current
Operating
Operating
(A)
Characteristics (mm)
Current (mA)
Number of Poles
2P
63
1
N
A type
36
80
T
2
N
100
16
4P
1
3
25
5
N
40
A type
70
63
T
2
4
N
80
100
57
3
4
4
4
6
8
3: Single phase, three holes
4: Three phase, four holes
Part No.
30
NDL6M-100 63/2/30/A
100
NDL6M-100 63/2/100/A
300
NDL6M-100 63/2/300/A
30
NDL6M-100 80/2/30/A
100
NDL6M-100 80/2/100/A
300
NDL6M-100 80/2/300/A
30
NDL6M-100 100/2/30/A
100
NDL6M-100 100/2/100/A
300
NDL6M-100 100/2/300/A
30
NDL6M-100 16/4/30/A
100
NDL6M-100 16/4/100/A
300
NDL6M-100 16/4/300/A
30
NDL6M-100 25/4/30/A
100
NDL6M-100 25/4/100/A
300
NDL6M-100 25/4/300/A
30
NDL6M-100 40/4/30/A
100
NDL6M-100 40/4/100/A
300
NDL6M-100 40/4/300/A
30
NDL6M-100 63/4/30/A
100
NDL6M-100 63/4/100/A
300
NDL6M-100 63/4/300/A
30
NDL6M-100 80/4/30/A
100
NDL6M-100 80/4/100/A
300
NDL6M-100 80/4/300/A
30
NDL6M-100 100/4/30/A
100
NDL6M-100 100/4/100/A
300
NDL6M-100 100/4/300/A
Width modular
2
One modular width: 9mm
Product Features
Standards and Certificates
Connect electric equipment
Modularization
Standard TH35mm DIN rail mounting
RoHS complied
IEC 60884-1, GB 2099.1; CCC.
Schematic
Width (mm)
Rated Current
(A)
Rated Working
Voltage (V)
18
10
250
36
16
250
54
16
440
72
25
440
Specification
Single phase,
two holes
Single phase,
three holes
Three phase,
four holes
Three phase,
four holes
Part No.
NDA1-10/22
NDA1-16/34
NDA1-16/46
NDA1-25/48
58
Working Condition
Rated operational voltage: AC 250V
Ambient temperature: -5℃ ~ 40℃
Air humidity: ≤95%
Altitude: ≤2000m
Pollution degree: Ⅱ
Service place without explosive media, gas and dust which are corrosive and conductive
Be mounted free from rain and snow
Product Features
Connect electric equipment
Modularization
Standard TH35mm DIN rail mounting
RoHS complied
NDA3 Series Modular Socket
Model and Implication
ND A 3
Schematic
Rated Current
(A)
Rated Working
Voltage (V)
36
10
250
36
16
250
NDA3
Implication
No.
Width (mm)
Specification
Single phase,
three holes
Part No.
NDA3-10/34
Brand code
Product code
A Modular Socket
Design code
3
Rated current (A)
10, 16
Number of holes
3
Modular width
4
Single phase,
three holes
NDA3-16/34
Note: One modular width is 9mm.
59
Rated current
10A
16A
Number of Holes
3
3
3: Single phase, three holes
Width modular
4
4
One modular width: 9mm
60