low voltage QZ - Series Miniature Circuit Breakers DIN Mount (grey body) Dual Mount (black body) Features Applications • • • • • • • • • • • • • • • • • • • • • • • • • • AC Circuit Breaker Hydraulic-Magnetic technology 100% rating capability, independent of ambient temperature One, two and three pole (UL). One, two, three pole and 1+N, 3+N (VDE). VDE approved, CE certified UL 1077 recognised (supplementary protector) Ratings 0.1 to 60 A (depends on specification and number of poles) Optional Auxiliary Switch / Trip Alarm - factory fitted (6.5 mm wide) Optional Shunt Trip (no approvals) Wide range of time delays and operating currents Precision tripping characteristics Ultra compact – 13 mm wide module Trip indication with mid-trip handle Reset immediately after overload DIN mount product in grey shells Dual mount product in black shells Ring terminal ready (terminal screw is removable) Suitable to use for electrical isolation Auxiliary Switch,Trip Alarm & Combo: Features • • • • • • Dual mount + Auxiliary (black body) AC branch circuit protection (IEC / EN 60947-2) Supplementary protection (UL 1077) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Optional Accessories • • AC and DC voltages • UL 489 listed (Auxiliary Switch: 6 A 250 V AC, • 0.5 A 80 V DC) • IEC 60947-5-1 approved (Auxiliary Switch: 6 A 240 V AC, • 0.5 A 110 V DC; Trip Alarm: 6 A 240 V AC, 0.5 A 110 V DC) • Factory fitted • Attached to right hand side of Circuit Breaker Compact 6.5 mm width Auxiliary Switch (DIN and Dual Mount) Auxiliary Switch + Trip Alarm (Dual Mount only) Trip Alarm (Dual Mount only) Handle lock Surface mounting clips Busbar 57 mm Escutcheon blank (Dual Mount only) 57 mm Safety blank (Dual Mount only) QZ-SERIES-DAT APR 2015 Data Sheet Page 1 of 8 low voltage QZ - Series Miniature Circuit Breakers Technical Data Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Interrupting Capacity 1 Circuit Breaker IEC / EN 60947-2, VDE 2 2 (1+N) 240 V AC 3 415 V AC 4 (3+N) 0.1 A 50 A 3 kA Product Type Approvals Supplementary Protector UL 1077 Tested without series fuse 1 3 Tested with and without series fuse Number of Poles Operating Voltages 1 1 2 3 120 V AC 277 V AC 480 V AC 240 V AC Minimum Current Rating Maximum Current Rating Interrupting Capacity 3 277 / 480 V AC 120 V AC 0.1 A 60 A 5 kA Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Interrupting Capacity 0.1 A 50 A 5 kA Motor Controller UL 60947-4-1A 2 480 V AC 0.1 A 30 A 5 kA 1 277 V AC 40 A 240 V AC 3 480 V AC 30 A Description Operating Temperature Range Mounting Options Time Delay Curves Breaker QZ 1 Pole & 2 Pole Data Sheet Page 2 of 8 -40oC to +85oC DIN Rail, Dual mounting (DIN & Mini), surface mounting clip 1, 2, 3, 9, OP Wire Size mm² (IEC) Wire Gauge (UL) Torque (IEC) Torque (UL) 0.75 - 35 mm² 18 – 2 – AWG 2.5 Nm 20 in-lb QZ-SERIES-DAT APR 2015 Comments Pozidriv #2 Combi head low voltage QZ - Series Miniature Circuit Breakers Long Code Example Code: QZ---AT-3(13)-D-2-50A-----Group 1 2 QZ Frame Switch / Neutral Long Code QZ - Group 1: Frame Type Code Description Comments QZ 13 mm wide Miniature Circuit Breaker UL 1077 / CSA, IEC / EN 60947-2,VDE, UL 60947-4-1A Requirement Group 2: Code Switch/Neutral Group 3: Auxiliary Group 4: No of Poles 3 4 Auxiliary + Triple pole Trip Alarm AT 3 5 6 7 8 9 10 11 13 mm module width DIN Rail Medium delay curve 2 Current Rating 50 A Future use No Shunt Trip Future use (13) D 2 50A - - - Description Comments Not applicable Overload poles do not have any further coding N Neutral Code Description Comments - Not applicable Use this code if no Auxiliary used A Auxiliary Switch (1 x Aux in 1 module) 6.5 mm module fitted on right-hand side (DIN & Dual Mount) T Trip Alarm (1 x Trip Alarm in 1 module) 6.5 mm module fitted on right-hand side (Dual Mount only) AT Auxiliary Switch + Trip Alarm combo (combined in 1 module) 6.5 mm module fitted on right-hand side (Dual Mount only) Code Description Comments 1 Single pole 2 Double pole 3 Triple pole 2 pole or1+N 4 Four pole 3+N only Group 5: Module Width Code Description Comments (13) 13 mm module width 13 mm per pole Group 6: Mounting Code Description Comments D DIN rail mount – 45 mm Escutcheon, grey body DIN mount supplied in grey only DM Dual mount – 57 mm Escutcheon, black body Group 7: Time Delays Code Description Instantaneous Trip Point (x In) Comments 1 Long time delay, high instantaneous trip 10 – 20 Orange handle 2 Medium time delay 5 – 10 White handle 3 Short time delay 3–5 White handle 9 Long time delay 7 – 12 White handle OP Instantaneous None White handle Group 8: Current Ratings Code / Description 0.1, 0.2, 0.3, 0.5, 1, 2, 3, 4, 5, 6, 7, 8 ,9, 10, 12, 15, 16, 20, 25, 30, 32, 35, 40, 45, 50, 60 A Dual mount supplied in black only Comments Ratings available vary depending on certification * Other ratings are available as special orders. Check availability. For future use (-) Group 9: Code Group 10: Shunt Trip Code Description Comments - Not applicable Use this code if no Shunt Trip is used V0 100 – 480 V AC Fly leads (approximately 60 mm long) V5 100 – 480 V AC Internally connected (not certified, only offered as special order) Group 11 Other voltages are available as special orders. Check availability. Code For future use (-) For options not listed, please contact CBI for assistance QZ-SERIES-DAT APR 2015 Data Sheet Page 3 of 8 low voltage QZ - Series Miniature Circuit Breakers Time Delay Curves 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 1 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 5000 4000 3000 2500 2000 1500 1000 500 400 300 200 130 100 105 0.001 150 Minimum % Rated Current 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 2 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 % Rated Current Data Sheet Page 4 of 8 QZ-SERIES-DAT APR 2015 4000 5000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Minimum low voltage QZ - Series Miniature Circuit Breakers Time Delay Curves 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 3 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 4000 5000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Minimum % Rated Current 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 9 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 4000 5000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Minimum % Rated Current QZ-SERIES-DAT APR 2015 Data Sheet Page 5 of 8 low voltage QZ - Series Miniature Circuit Breakers Time Delay Curves 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE OP Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 5000 4000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Minimum % Rated Current * The published time delay curves are generated at 30oC ambient temperature with the Circuit Breaker mounted in the up-right position. The “must hold”, “must trip” and “instantaneous trip” current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Internal Impedance vs Current Rating Q-Range impedance values 10,000 Impedance (m Ω ) 1,000 100 10 Maximum 1 0.1 Data Sheet Page 6 of 8 Minimum 0 5 10 15 QZ-SERIES-DAT APR 2015 20 25 30 35 Amp rating 40 45 50 55 60 65 low voltage QZ - Series Miniature Circuit Breakers Typical outline of Auxiliary Switch / Trip Alarm Auxiliary available (6.5 mm module width) to match the unit to which it is attached. Available types as listed in Group 3: 57.0 [2.244] 97.2 [3.827] Typical outline for an Auxiliary module attached to a Dual mount single pole Circuit Breaker All dimensions in mm [ inch ] Tolerance ± 0.2 unless otherwise specified 69.8 [2.750] 12 NC 14 NO 11 14 11.7 [0.461] 6.5 [0.256] 2.80 [0.110] [ 1.4 0.055] 0.8 [0.0315] 18.0 [0.709] 37.8 [1.5900] 45° C 12 0.5 [0.020] 11 12 Auxiliary Switch 14 A005438 S 15 11 TEST BUTTON (on Trip Alarm only) 18 C 15 16 NO 15 18 V D E 18 16 Q-AUX NC RoHS Trip Alarm Switch Uimp = 2.5kV Icw = 0.1kA UTIL. CAT. AC12/DC12 POLLUTION DEGREE 3 6.0 [0.236] Circuit Diagram when the Circuit Breaker is in the “OFF” position 16 35.5 [1.400] 18.0 [0.709] AUXILIARY/ TRIP ALARM (AT) TRIP ALARM SWITCH AUXILIARY SWITCH 110 VDC : 0,5A 110 VDC : 0,5A 240 VAC : 6A 240 VAC : 6A EN/IEC 60947-5-1 19.3 ± 0.3 [0.760 ± 0.012] 2.3 [0.090] • • Type T - Trip Alarm as shown in outline drawings (fitted on a Dual mount product) Type AT - Auxiliary Switch + Trip Alarm (as shown) Type A - Auxiliary Switch 6.8 [0.270] • CONNECTING TERMINALS DETAIL (COMMON TO ALL) QZ-SERIES-DAT APR 2015 Data Sheet Page 7 of 8 low voltage QZ - Series Miniature Circuit Breakers Outline Dimensions: Dual mount 69.1 2.720 61.0 13.0 2.400 19.6 1.024 39.0 1.536 2.801 71.2 3.827 97.2 (Ref) 2.244 57.0 3.244 0.772 82.4 26.0 0.512 19.6 13.0 0.772 5.0 0.512 45.0 0.197 1.772 All dimensions in mm [ inch ] Tolerance ± 0.2 [ 0.008 ] unless otherwise specified 64.8 2.551 Outline Dimensions: DIN mount 68.1 2.681 60.0 2.362 18.6 1.024 39.0 1.536 2.803 3.827 97.2 (Ref) 1.772 45.0 71.2 0.512 3.244 82.4 26.0 13.0 0.732 18.6 13.0 0.732 5.0 0.512 44.0 0.197 1.732 63.8 2.512 All dimensions in mm [ inch ] Tolerance ± 0.2 [ 0.008 ] unless otherwise specified Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 90 Fairbank Road Clayton South Melbourne Victoria 3169 Australia Tel: +61 3 9590 3500 Fax: +61 3 9551 1051 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au Data Sheet Page 8 of 8 QZ-SERIES-DAT APR 2015 SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com A member of the Group