Temposonics ® ,
HPH Operating Instruction
Precise position measurement in high pressure housing
This High Pressure Housing is ATEX EEx approved and UL and cUL approved for use in hazardous locations with Temposonicsâ position sensors.
The ATEX, UL and cUL approvals cover flammable gases, vapors and liquids. This housing is made to fit Temposonics R-series sensors with analog and digital outputs as well as the S-series
ServoSensorä. Both fixed cable and connector versions can be used.
When using a standard sensor in this housing you get a cost efficient solution for use in hazardous locations which also allows easy sensor replacement.
Safety Instructions
The sensor must only be used according to the EX-certificate no.
Demko 07 ATEX 142619X or UL listing no. 2PD0 See product name plate for actual approvals.
To reduce risk of ignition in hazardous atmospheres, disconnect the equipment from the supply circuit before opening. Keep assembley tightly closed when in operation.
For use according to UL-listing, conduit seals must be installed within 18" of the inclosure. Must be connected to a Class 2 power supply The housing parts must be kept as one unit.
They are not interchangeable with parts from similar housings.
Only tools applicable for use in explosive atmosphere must be used.
When mounting the rod in “ZONE 0” it is necessary to prevent any leakage between “ZONE 0” and the surrounding environment.
The sensor house must be connected to an equipotential bonding system or an earthing system.
Technical Data:
ATEX:
Material:
Cable gland thread:
Ingress protection codes:
Approved sensors:
Moutning flange: pressure rating:
Peak pressure:
Magnet typ:
Level measurement: suplly voltage:
Operating temperature:
II 2 G Ex d IIC T5 T amb
-40°C to +60°C
II 2 D Ex tD 20/A21 IP68 T 100°C
ITS09ATEX16296X
In accordance with EN 60079-0:2006
EN 60079-1:2007, EN 60079-26:2004, EN 60079-0:2006 and EN 61241-1:2004
Only with ATEX approved cable glands
Class 1, Division 1, Groups A, B, C, and D hazardous locations, temperatur code T5
As to fire electrical shock and explosion hazardous only UL certificated Nr. 2PD0.
In accordance with UL 1203 standard.
Only with UL approved cable glands
Stainless steel AISI 316L (1.4404)
M20 x 1,5 or 1/2” NPT
IP68 (only with IP68 approved cable gland)
G-Series Analog+Digital
L-Series Start/Stop
R-Series Analog
R-Series Profibus
R-Series CANBUS
R-Series SSI
R-Series DeviceNet
M18 x 1,5 or 3/4” - 16UNF - 3A
350 bar
530 bar
Ring magnets
Float on request
24 VDC / 150 mA maximal
-40 °C to +60 °C (Basis T5)
Maintainance & Service:
The housing is maintenance free. If the position sensor inside gets defective, open the housing and replace the sensor and close it again according to the description in this manual.
Replace only with approved sensors listed above.
2
¥ ,
"DDFTTPSJFT
%JTDSJQUJPO
M20 x 1,5 cable gland, ATEX
M20 x 1,5 cable gland, ATEX
1/2” NPT cable gland, ATEX
Stainless steel nut for flange
4-8,5 mm cable-Ø, stainless steel
8,5 - 16 mm cable-Ø, stainless steel
3,4 - 8,4 cable-Ø, nickel plated brass
1BSU/P
CG-816679
CG-816609
403 042
M18 x 1,5
Spannre tool DIN 1018A AMF 80-90 mm
6 pol. female connector M16 370 423
6 pol. female connector M16, with 10 m PUR-cable 370 423 / 10m 530052
7 pol. female connector M16 370 624
7 pol. female connector M16, with 10 m PUR-cable 370 624 / 10m 530052
HPH rotation adapter for M18, M30x1,5 RTA-M18
HPH rotation adapter for 3/4” UNF, 1 1/16 RTA-3/4” UNF-2
HPH rotation adapter for 3/4” UNF, 1 1/4” 253961
UPSRVF WBMVFT
CPEZ
10 Nm
DBQOVU
35 Nm
7 Nm 12,5 Nm
11,5 Nm 17,5 Nm
10 Nm 10 Nm
Ø 33
Ø 4,2 on circle Ø 24
Height: 8
Ø 13,5
Ring magnet OD33
Part No. 201 542-2
PA-Ferrit-GF20
Weight ca. 14g operating temperature: -40 ... +100 ∞ C
Temposonics ® ,
HPH Operating Instruction
Mounting Discritpion:
1.
Open the housing by turning the top counter clockwise. When opening after a sensor is installed, it is very important to completely loosen the cable gland in order to protect the cable against twisting and physical damage.
The normal way is that the sensor and the HPH housing are in one order and then
MTS supply the sensor mounted in the WPH housing.
Go to step 7.
2.
Remove rod or profile from the sensor.
Separate the plastic tube from the sensor.
3.
Cable gland
3.1
Insert the cable through the gland
4
Temposonics ® ,
HPH Operating Instruction
3.2
Insert the connector through the top.
3.3
Connect to the sensor and insert a bag of Desiccant in the top.
3.4
Assemble the top and bottom turning clockwise.
3.5
Tighten firmly until the top and bottom flanges come together.
5
Temposonics ® ,
HPH Operating Instruction
3.6
Tighten gable gland according to the manufacturer's specifications.
4.
Side mounted cable gland(s)
4.1
Enter the cable through the gland without tightening.
4.2
For cable sizes larger than 7mm or very rigid cables, you may need to remove the outer insulation jacket from inside the cable gland to the connector.
4.3
Insert and fasten the sensor.
6
Temposonics ® ,
HPH Operating Instruction
4.4
Make the connections.
4.5
Insert a bag of Desiccant in the top.
4.6
Assemble the top and bottom turning clockwise and tighten firmly until top and bottom flanges come together. (see fig. 11) Tighten the cable glands according to manufacturer's specifications.
5.
Mount the grounding cable.
7
Temposonics ® ,
HPH Operating Instruction
6.
Tighten the lock screw with min. 1.5Nm torque.
MTS Sensor Technologie
GmbH & Co. KG
Auf dem Schüffel 9
58513 Lüdenscheid, Germany
Tel. + 49-23 51-95 87 0
Fax + 49-23 51-5 64 91
E-Mail: info@mtssensor.de
www.mtssensor.de
Document Part Number: 20140317 (EN) 03/2014
MTS and Temposonics ® are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in Germany.
Copyright © 2013 MTS Sensor Technologie GmbH & Co. KG. Alterations reserved. All rights reserved in all media. No license of any intellectual property rights is granted. The information is subject to change without notice and replaces all data sheets previously supplied. The availability of components on the market is subject to considerable fluctuation and to accelerated technical progress. Therefore we reserve the right to alter certain components of our products depending on their availability. In the event that product approbations or other circumstances related to your application do not allow a change in components, a continuous supply with unaltered components must be agreed by specific contract.
MTS Systems Corporation
Sensors Division
3001 Sheldon Drive
Cary, N.C. 27513, USA
Tel. + 1-919-677-0100
Fax + 1-919-677-0200
E-Mail: sensorsinfo@mts.com
www.mtssensors.com
MTS Sensors Technology Corp.
737 Aihara-cho,
Machida-shi, Japan
Tel. + 81-42-775-3838
Fax + 81-42-775-5516
E-Mail: info@mtssensor.co.jp
www.mtssensor.co.jp
Temposonics ®
, HPH Betriebsanleitung
Temposonics ®
, HPH Betriebsanleitung
Temposonics ®
, HPH Betriebsanleitung
Temposonics ®