this product`s Tech Data Sheet

advertisement
N100 Control and signalling units 30.5mm
Pilot lights
Refer Catalogue C-100
Components for self assembly
IP 66 pilot lights less lamp and lens
Type
Lamp
Full voltage
Cat. No.
NVFC
Ba 15d
IP 66 pilot lights with lamp less lens 1)
Primary
voltage
NV2C transformer type 4)
Type
Cat. No.
110 V AC
Ba9s-12-6 V-1.2
NV1C
Transformer )
230/240 V AC
Ba9s-12-6 V-1.2
NV2C
Transformer 3)
415 V AC
Ba9s-12-6 V-1.2
NV3C
Resistor
230/240 V AC
Ba 15d 250 V
NV2RC
Resistor
415 V AC
Ba 15d 250 V
NV3RC
Economy Resistor
110 V AC
Ba 15d 110 V
NV1EC
Economy Resistor
230/240 V AC
Ba 15d 250 V
NV2EC
3
NVFC full voltage type
Lamp
Transformer )
3
IP 54 push-to-test pilot light with lamp less lens 1)
Primary
voltage
Type
110 V AC
6.3 V
Ba9s
W1C
Unguarded transformer 3)
240 V AC
6.3 V
Ba9s
W2C
Unguarded transformer )
415 V AC
6.3 V
Ba9s
W3C
Unguarded full voltage )
–
–
Ba9s
WFC 1)
Guarded transformer 3)
110 V AC
6.3 V
Ba9s
WG1C
Guarded transformer 3)
240 V AC
6.3 V
Ba9s
WG2C
Guarded transformer )
415 V AC
6.3 V
Ba9s
WG3C
Guarded full voltage )
–
–
Ba9s
WGFC 1)
3
2
3
2
W2C unguarded
transformer type
Lens to suit pilot lights and push to test pilot light
Polycarbonate
beehive style
Colour
Glass and plastic lens
Cat. No. 1PR & 1GM
Glass
beehive style
Plastic standard
style 5)
Red
1PR
1GR
1PRO
Green
1PG
1GG
1PGO
White
1PW
1GW
1PWO
Amber
1PT
1GT
1PTO
Blue
1PM
1GM
1PMO
Clear
1PC
1GC
1PCO
Notes:
)
)
3
)
4
)
5
)
1
2
Glass dome type lenses
Cat. No.
Unguarded transformer )
3
NV2RC resistor type
Secondary
voltage
Lamp
Supplied without legend plate.
Supplied without lamp and lens.
Spare transformers available Cat. No. N100-110T, N100-240T, N100-415T
Shown with optional legend plate fitted.
Recommended for use with “push to test”.
Heavy duty control units
Wide range of pushbuttons with
standard inserts, raised buttons, legend
plates, full range of colours
Full voltage type pilot lights and
indicators also 'Push-to-Test'
Touch a finger to any NHP pushbutton, and there’s positive
response every time. Why are NHP control units more dependable
than others? Because, with each operation, the fine silver contacts
are cleaned. The rolling, wiping action between the moveable and
stationary contacts as they make or break the circuit, wipes off any
dust or non-conducting film that may be present. It’s an NHP
exclusive.
Selector switches with knob, lever or
key operators
Features
• Interchangeability of many parts
• Designed for minimum front projection of operators
• Stationary terminals are held solidly to the blocks
• Fine silver with exclusive wipe action contacts are used
throughout the line
• Available in a wide variety of standard and custom-built stations
• Manufactured from non-ferrous components
• All contact blocks with finger protection
Australian made products
Pull to reset and twist to reset
mushroom head operators
Also available standard range of
Pushbutton stations in fibreglass or
cast aluminium including 'stoplock'
Emergency stop stations
Corrosive and water resistant
heavy duty control units
Full voltage type pilot light
Short lever selector switch
Pushbutton unit with chrome
ferrule, legend and insert
Standard pushbutton unit
Pushbutton unit with
hoseproof neoprene cover
Mushroom head operator
momentary contact
Pushbutton unit with
legend plate and insert
Mushroom head operator,
pull to reset, padlockable
“Push-to-test” IP 54 transformer type
pilot light with plastic lens
Mushroom head operator,
twist to reset
NT1-DESL
SS8 with operators
fitted
FT1-DES
IP 65
Corrosive and water resistant
heavy duty control units
Refer Catalogue C-100
N100 operators can be customised to suit every application.
By selecting components you can order the exact operator to suit your needs.
Pushbuttons and inserts
Special operator heads
Selector and key selector switches
Pilot lights and lenses
Contact blocks
Legend plates
3
1
2
4
Pushbuttons
Eg.
1 NTOCO
2 P23
Operator
Bodies
3 NPAFP
Inserts/
Mushroom
Heads
Contact
Blocks
4 B11
Legend
Plates
2
1
3
Selector and key selector switches
Eg.
1 NUCC
Operator
Bodies
2 NPAFP
Contact
Blocks
3 B72
Legend
Plates
30.5mm PILOT LIGHTS
Type N100
Features
NVFC full voltage type ) )
1
2
■
Non ferrous components used throughout
■
Full voltage, resistor and transformer types
■
Incandescent or LED illumination
■
Polycarbonate or glass lens
■
Heavy duty components
■
IP66 protection
■
Separate earth termination 4)
Description
Primary voltage types
NV2C transformer type 1) 2)
Shown with optional legend plate
fitted.
Secondary voltage
Lamp type
Protection
Temperature rating
Weight
Non
ferr
and o u s
IP66
Prot
ectio
n
Full voltage 4)
Transformer 3) 4)
Resistor 3) 4)
Economy resistor
3 4
) )
Cat. No.
NVFC
Cat. No.
NV_C
Cat. No.
NV_RC
Cat. No.
NV_EC
110, 240V
240V
—
—
Ba15d
IP66
-30˚C +80˚C
11g
110, 240
415V
6.3V
Ba9s
IP66
-30˚C +80˚C
21g
95V, 98V
230V
Ba15d
Ba15d
IP66
IP66
-30˚C +80˚C -30˚C +80˚C
19g
19g
Zinc chrome
Zinc chrome
Zinc chrome Zinc chrome
Construction
Housing and ferrule
Dimensions (mm)
48
35
PRIMARY
SECONDARY
Transformer pilot light
19
27
44
NV2RC resistor type 1) 2)
Full voltage pilot light
Notes: 1)
2
)
3
)
4
)
Pictures shown with lenses and globes fitted.
Lenses and globes to be ordered separately.
Insert 1 - 110V, 2 - 240V, 3 - 415V (e.g.. NVIC = 110V).
Use 1X9E earth ring for separate earth terminal. Available at extra cost.
34
PRIMARY
SECONDARY
45
30.5mm PUSH–TO–TEST PILOT LIGHTS
Type N100
Features
Unguarded push–to–test
transformer operator
■
Non ferrous components used throughout
■
Guarded or unguarded
■
Polycarbonate or glass lens 2)
■
Heavy duty components
■
Transformer 110V, 240V or 415V
■
Standard normally open contacts
■
Incandescent or LED indication
■
IP54 protection
Unguarded full voltage
transformer
Unguarded
transformer
Guarded
transformer
Cat. No.
WFC 1) 4)
Cat. No.
W_C 1) 3 ) 4)
Cat. No.
WG_RC 1) 3 ) 4)
240V
Ba9s
IP54
-30˚C +80˚C
20g
110, 240
415V
6.3V
Ba9s
IP54
-30˚C +80˚C
22g
110, 240
415V
6.3V
Ba9s
IP54
-30˚C +80˚C
22.5g
Zinc chrome
Zinc chrome
Zinc chrome
Description
Primary voltage type
Guarded push–to–test transformer
indicator shown with optional legend
plate fitted.
Secondary voltage
Lamp type
Protection
Temperature rating
Weight
Construction
Housing and ferrule
Wiring diagram
Push–to–test pilot light
Lighted pushbutton
Dimensions (mm)
Notes: 1)
2
)
3
)
4
)
Pictures shown with lenses and globes fitted.
Lenses and globes to be ordered separately.
Insert 1 - 110V, 2 - 240V, 3 - 415V (e.g.. W2C = 240V).
Use 1X9E earth ring for separate earth terminal. Available at extra cost.
Download