N100 Control and signalling units 30.5mm Pilot lights Refer Catalogue C-100 Components for self assembly IP 66 pilot lights less lamp and lens Type Lamp Full voltage Cat. No. NVFC Ba 15d IP 66 pilot lights with lamp less lens 1) Primary voltage NV2C transformer type 4) Type Cat. No. 110 V AC Ba9s-12-6 V-1.2 NV1C Transformer ) 230/240 V AC Ba9s-12-6 V-1.2 NV2C Transformer 3) 415 V AC Ba9s-12-6 V-1.2 NV3C Resistor 230/240 V AC Ba 15d 250 V NV2RC Resistor 415 V AC Ba 15d 250 V NV3RC Economy Resistor 110 V AC Ba 15d 110 V NV1EC Economy Resistor 230/240 V AC Ba 15d 250 V NV2EC 3 NVFC full voltage type Lamp Transformer ) 3 IP 54 push-to-test pilot light with lamp less lens 1) Primary voltage Type 110 V AC 6.3 V Ba9s W1C Unguarded transformer 3) 240 V AC 6.3 V Ba9s W2C Unguarded transformer ) 415 V AC 6.3 V Ba9s W3C Unguarded full voltage ) – – Ba9s WFC 1) Guarded transformer 3) 110 V AC 6.3 V Ba9s WG1C Guarded transformer 3) 240 V AC 6.3 V Ba9s WG2C Guarded transformer ) 415 V AC 6.3 V Ba9s WG3C Guarded full voltage ) – – Ba9s WGFC 1) 3 2 3 2 W2C unguarded transformer type Lens to suit pilot lights and push to test pilot light Polycarbonate beehive style Colour Glass and plastic lens Cat. No. 1PR & 1GM Glass beehive style Plastic standard style 5) Red 1PR 1GR 1PRO Green 1PG 1GG 1PGO White 1PW 1GW 1PWO Amber 1PT 1GT 1PTO Blue 1PM 1GM 1PMO Clear 1PC 1GC 1PCO Notes: ) ) 3 ) 4 ) 5 ) 1 2 Glass dome type lenses Cat. No. Unguarded transformer ) 3 NV2RC resistor type Secondary voltage Lamp Supplied without legend plate. Supplied without lamp and lens. Spare transformers available Cat. No. N100-110T, N100-240T, N100-415T Shown with optional legend plate fitted. Recommended for use with “push to test”. Heavy duty control units Wide range of pushbuttons with standard inserts, raised buttons, legend plates, full range of colours Full voltage type pilot lights and indicators also 'Push-to-Test' Touch a finger to any NHP pushbutton, and there’s positive response every time. Why are NHP control units more dependable than others? Because, with each operation, the fine silver contacts are cleaned. The rolling, wiping action between the moveable and stationary contacts as they make or break the circuit, wipes off any dust or non-conducting film that may be present. It’s an NHP exclusive. Selector switches with knob, lever or key operators Features • Interchangeability of many parts • Designed for minimum front projection of operators • Stationary terminals are held solidly to the blocks • Fine silver with exclusive wipe action contacts are used throughout the line • Available in a wide variety of standard and custom-built stations • Manufactured from non-ferrous components • All contact blocks with finger protection Australian made products Pull to reset and twist to reset mushroom head operators Also available standard range of Pushbutton stations in fibreglass or cast aluminium including 'stoplock' Emergency stop stations Corrosive and water resistant heavy duty control units Full voltage type pilot light Short lever selector switch Pushbutton unit with chrome ferrule, legend and insert Standard pushbutton unit Pushbutton unit with hoseproof neoprene cover Mushroom head operator momentary contact Pushbutton unit with legend plate and insert Mushroom head operator, pull to reset, padlockable “Push-to-test” IP 54 transformer type pilot light with plastic lens Mushroom head operator, twist to reset NT1-DESL SS8 with operators fitted FT1-DES IP 65 Corrosive and water resistant heavy duty control units Refer Catalogue C-100 N100 operators can be customised to suit every application. By selecting components you can order the exact operator to suit your needs. Pushbuttons and inserts Special operator heads Selector and key selector switches Pilot lights and lenses Contact blocks Legend plates 3 1 2 4 Pushbuttons Eg. 1 NTOCO 2 P23 Operator Bodies 3 NPAFP Inserts/ Mushroom Heads Contact Blocks 4 B11 Legend Plates 2 1 3 Selector and key selector switches Eg. 1 NUCC Operator Bodies 2 NPAFP Contact Blocks 3 B72 Legend Plates 30.5mm PILOT LIGHTS Type N100 Features NVFC full voltage type ) ) 1 2 ■ Non ferrous components used throughout ■ Full voltage, resistor and transformer types ■ Incandescent or LED illumination ■ Polycarbonate or glass lens ■ Heavy duty components ■ IP66 protection ■ Separate earth termination 4) Description Primary voltage types NV2C transformer type 1) 2) Shown with optional legend plate fitted. Secondary voltage Lamp type Protection Temperature rating Weight Non ferr and o u s IP66 Prot ectio n Full voltage 4) Transformer 3) 4) Resistor 3) 4) Economy resistor 3 4 ) ) Cat. No. NVFC Cat. No. NV_C Cat. No. NV_RC Cat. No. NV_EC 110, 240V 240V — — Ba15d IP66 -30˚C +80˚C 11g 110, 240 415V 6.3V Ba9s IP66 -30˚C +80˚C 21g 95V, 98V 230V Ba15d Ba15d IP66 IP66 -30˚C +80˚C -30˚C +80˚C 19g 19g Zinc chrome Zinc chrome Zinc chrome Zinc chrome Construction Housing and ferrule Dimensions (mm) 48 35 PRIMARY SECONDARY Transformer pilot light 19 27 44 NV2RC resistor type 1) 2) Full voltage pilot light Notes: 1) 2 ) 3 ) 4 ) Pictures shown with lenses and globes fitted. Lenses and globes to be ordered separately. Insert 1 - 110V, 2 - 240V, 3 - 415V (e.g.. NVIC = 110V). Use 1X9E earth ring for separate earth terminal. Available at extra cost. 34 PRIMARY SECONDARY 45 30.5mm PUSH–TO–TEST PILOT LIGHTS Type N100 Features Unguarded push–to–test transformer operator ■ Non ferrous components used throughout ■ Guarded or unguarded ■ Polycarbonate or glass lens 2) ■ Heavy duty components ■ Transformer 110V, 240V or 415V ■ Standard normally open contacts ■ Incandescent or LED indication ■ IP54 protection Unguarded full voltage transformer Unguarded transformer Guarded transformer Cat. No. WFC 1) 4) Cat. No. W_C 1) 3 ) 4) Cat. No. WG_RC 1) 3 ) 4) 240V Ba9s IP54 -30˚C +80˚C 20g 110, 240 415V 6.3V Ba9s IP54 -30˚C +80˚C 22g 110, 240 415V 6.3V Ba9s IP54 -30˚C +80˚C 22.5g Zinc chrome Zinc chrome Zinc chrome Description Primary voltage type Guarded push–to–test transformer indicator shown with optional legend plate fitted. Secondary voltage Lamp type Protection Temperature rating Weight Construction Housing and ferrule Wiring diagram Push–to–test pilot light Lighted pushbutton Dimensions (mm) Notes: 1) 2 ) 3 ) 4 ) Pictures shown with lenses and globes fitted. Lenses and globes to be ordered separately. Insert 1 - 110V, 2 - 240V, 3 - 415V (e.g.. W2C = 240V). Use 1X9E earth ring for separate earth terminal. Available at extra cost.