Annex to Certificate IECEx VTT 14.0020X 1 (4) Rated values 1. Boxes with terminals only (terminal boxes) Voltage: Max 50 V Number of cable glands: According to Table 2 2. Boxes with terminals, transmitters, arresters and proximity transducer amplifiers (instrument boxes) Voltage as above, and additionally: Ex i transmitters: Supply and output circuit (terminals 1 and 2): In type of protection intrinsic safety Ex ia IIC or Ex ia IIIC, only connection to a certified intrinsically safe circuit with the following maximum values: Ui = 30 V, Ii = 120 mA, Pi = 0.84 W, Li = 10 H, Ci = 1 nF. Sensor circuits (terminals 3...6): In type of protection intrinsic safety Ex ia IIC or Ex ia IIIC, with the following maximum values: U o = 9.6 V, Io = 28 mA, Po = 67 mW, Lo = 35 mH, Co = 3.5 F. Ex i arresters: Ui = 30 V, Ii = 500 mA, Pi = 850 mW, Li = 1 H, Ci = 1.1 nF Ex i proximity transducer amplifiers: Ui = -28 V, Ii = 140 mA, Pi = 0.91 W; Terminal J1: Ci = 0, Li = 10 H; Terminal J2: Ci = 5.7 nF, Li = 0.85 mH. Components Enclosures: ROSE Systemtechnik GmbH, types 34… II 2 G Ex e IIC Gb II 2 D Ex tb IIIC Db, IP66 Tamb = -55 C …+135 C Tamb = -50 C …+100 C (with inspection window) IECEx PTB 07.0059U, PTB 00 ATEX 1101U Ensto Finland Oy, types Cubo X… II 2 G Ex e IIC Gb II 2 D Ex t IIC Db, IP66 Tamb = -55 C …+85 C IECEx DNV 11.0005U, DNV 11 ATEX 98909U IECEx PRE 14.0042U, Presafe 14 ATEX 5378U Annex to Certificate IECEx VTT 14.0020X 2 (4) Terminals: Phoenix Contact; see types, certificate references, and rated cross sections in Table 1 II 2 GD Ex eb IIC Tamb = -60 C …+110 C Table 1: The rated terminal cross sections, allowable cable cross sections and the component certificates for the Phoenix Contact terminal types included in this certificate. In addition, protective conductor terminal blocks (listed types with suffix –PE) are allowed and the same rated terminal cross sections and allowable cable cross sections apply. Phoenix Contact terminal type ST 1,5 ST 1,5-QUATTRO ST 2,5 ST 2,5-QUATTRO ST 4 ST 4-QUATTRO ST 6 UT 6 ST 10 Rated terminal cross section [mm2] Cable cross sections [mm2] Certificates 1.5 0.2–1.5 IECEx KEM 06.0043U, KEMA 01 ATEX 2129U 2.5 0.2–2.5 IECEx KEM 06.0051U, KEMA 00 ATEX 2052U 4 0.2–4 6 6 10 0.2–6 0.2–6 1.5–10 Cable glands: Hummel AG, type HSK-M-EMV-Ex II 2 G Ex e IIC Gb II 1 D Ex ta IIIC Da, IP 66 Tamb = -60 C …+95 C IECEx KEM 07.0014X, KEMA 99 ATEX 6971X Hawke International, types 501/421 and 501/414 II 2 G Ex e IIC Gb II 2 D Ex tb IIIC Db, IP66 Tamb = -60 C …+80 C IECEx BAS 06.0013X, Baseefa 06 ATEX 0056X IECEx KEM 06.0050U, KEMA 00 ATEX 2129U IECEx KEM 06.0027U, KEMA 04 ATEX 2048U IECEx KEM 06.0033U, KEMA 01 ATEX 2260U Annex to Certificate IECEx VTT 14.0020X 3 (4) Table 2: Maximum number of cable glands. ZWT1 _505020-_BS ZWT1 _505020-_SS PG thread Metric thread NPT thread All side walls Back wall ZWT1 _323220-_BS ZWT1 _323220-_SS ZWT1 _323223-_BW ZWT1 _323223-_SW All side Back wall walls PG 7 or PG9 PG 11 PG 13,5 or PG 16 M12 32 48 18 32 24 48 36 PG 21 PG 29 M25 M32 13 8 PG 36 M40 3/8” NPT 1/2” or 3/4” NPT 1” NPT 1 1/4” NPT 1 1/2” NPT 6 M16 M20 ZWT1 _202012-_BS ZWT1 _202012-_SS Walls with gland plate 8 Back wall 27 Walls without gland plate 8 18 16 27 24 8 5 8 5 6 4 20 12 7 4 11 6 3 2 3 2 2 2 9 3 5 2 0 1 Closing devices (plugs): Hummel Elektrotechnik GmbH, type V-MS-Ex 1.199.****.** II 2 G Ex e II II 1 D Ex tD A20 IP68 Tamb = -60 C …+180 C IECEx BVS 07.0021, DMT 03 ATEX E 049 Hawke International, type 387 II 2 G Ex e IIC Gb II 2 D Ex tb IIIC Db, IP66 Tamb = -60 C …+80 C IECEx BAS 06.0029U, Baseefa 06 ATEX 0118U Adaptors: Hawke International, type 476 II 2 G Ex e IIC Gb II 2 D Ex tb IIIC Db, IP66 Tamb = -60 C …+80 C IECEx BAS 11.0037X, Baseefa 11 ATEX 0067X Transmitters: PR Electronics A/S, type 5335D HART II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIC Da Tamb = -40 C …+85 C IECEx KEM 10.0083, KEMA 03 ATEX 1537 6 Annex to Certificate IECEx VTT 14.0020X Overvoltage arresters: Phoenix Contact GmbG & Co., type Plugtrab PT 4-EX(I)-24DC-ST II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIC T135 C Da Tamb = -40 C …+80 C IECEx KEM 10.0063X, KEMA 00 ATEX 1099X Proximity transducer amplifiers: Bently Nevada Inc, type 3300XL Proximitor Sensor, 330180-51-05 II 1 G Ex ia IIC T4 Ga Tamb = -51 C …+100 C IECEx BAS 04.0055X, BAS 99 ATEX 1101 The above mentioned components, excluding enclosures, may be replaced by equivalent Ex certified components taking into consideration the required equipment group, temperature classification and creepage and clearance distances. Degree of protection IP 66 Documents The equipment is installed in the enclosure as shown in the following principle drawings: ABB Oy: 3AFP 9923012 rev C ABB Oy: 3AFP 9923014 rev C ABB Oy: 3AFP 9923016 rev C ABB Oy: 3AFP 9923017 rev C 4 (4)