Features
BB2CL
• The tool-less design enables Croc-Lok assemblies to be field
installed in less than 4 seconds. Simply squeeze, secure
and walk away.
• Outlet boxes mount to the Croc-Lok with single screw.
• The Croc-Lok Box Mounting Bracket is an improved version
of the current BB2TS Slider Bracket.
• Recently redesigned to include raised dimples that lock into
holes on the telescoping bar.
• Redesign includes screw holes in the face plate, which
create the option to screw the Croc-Lok to a telescoping bar
New
BB2CL
installed on
BB2-16T
UPC/Part
Number
782051 51291
782051 51292
782051 51293
Catalog
Number
BB2CL
BB216TCL
BB224TCL
Stud
Spacing
Description
Box
Qty
N/A
11” to 16”
15” to 24”
Croc-Lok only
BB2-16T with Croc-Lok
BB2-24T with Croc-Lok
50
20
20
Patent Pending
Note: Secures to Cooper B-Line BB2-16T and BB2-24T telescoping brackets only. For a standard 21/8” deep box, the stud
depth must be 31/2” or greater. For a shallow 11/2” deep box, the stud depth must be 21/2” or greater.
Telescoping Bar with Croc-Lok Assemblies
Features
BB216TCL
• The Croc-Lok Box Mounting Bracket is an improved version of the
current BB2TS Slider Bracket.
• The narrow width of the Croc-Lok allows for up to three - 4” boxes
to be installed within a 16” stud spacing, and up to four - 4” boxes
within a 24” stud spacing.
• Its design offers placement flexibility by locking in place firmly at any
position along the telescoping bar.
• Croc-Lok box assemblies are sold with or without telescoping bars.
To reduce the lines on your BOM consider ordering Croc-Lok box
assemblies and field install.
• Croc-Lok™ box assemblies can be attached before or after the
telescoping bar is mounted in the stud wall.
• Download the Ruff-IN configurator for free at
www.cooperbline.com/ruff-in and see for yourself how much easier
it allows you to create Ruff-IN part numbers.
Basic Ruff-IN = 3-5 day lead-time for quantities of 1000 or less.
BB2CL-4D
BB2CL-2104DA-WAAR
Ruff-IN with Wiring Devices = 10-15 day lead-time for quantities of 500 or less.
Non Stock Components = Call factory for lead-time.
Read safety/installation instruction sheets in packages before use. These products are designed for positioning only. No load rating.
8
Croc-Lok™ Box Mounting Bracket Assemblies
† Example Part Number
BB216TCL - 1 10 4D
BB2
A _ - _ _ _ _ _ _ - W AAR - _ _
1
2
3
4
5
6
7
Step 1
8
9
8
10
Step 2
8
11
12
2
Step 3
4
Plaster Ring Style (see pgs. 30-31)
1 = One Device
2 = Two Device
R = Round
1AJ = One Device Adjustable *
2AJ = Two Device Adjustable *
Blank = Box Only
3
Plaster Ring Size
1/4”
04 =
Raise
08 = 1/2” Raise
10 = 5/8” Raise
12 = 3/4” Raise
16 = 1” Raise
20 = 11/4” Raise
24 = 11/2” Raise
32 = 2” Raise
Blank = Box Only or
Adjustable Plaster Ring
4
Box Style (see pg. 32)
4D = 4” Sq., 21/8” Deep
436 = 4” Sq., 21/8” Deep, 1” KO
4 = 4” Sq., 11/2” Deep
432 = 4” Sq., 21/8” Deep, 3/4” KO
5D = 411/16” Sq., 21/8” Deep
560 = 411/16” Sq., 21/8” Deep, 1” KO
5 = 411/16” Sq., 11/2” Deep
554 = 411/16” Sq., 21/8” Deep, 3/4” KO
5
6
7
8
9
8
10
8
Step 2
11
12
Step 3
For Installation Of Second Box - If Desired
Step 1 - Basic Ruff-In
2
5
Step 1
For Installation Of One Box
1 Stud Spacing
BB216TCL = 11” to 18” Mounting Bar &
Croc-Loc Assembly
BB224TCL = 15” to 26” Mounting Bar &
Croc-Loc Assembly
BB2CL = Croc-Loc Assembly Only
_ _ - _ _ _ _ _ _ - _ _
Step 2 - Connectors
7
Connector Top Left KO
Blank = No Attachment
L = Attachment Present
8
Connector Type (see pg. 33)
Blank = None
A = QLK50S (1/2” single MC)
B = QLK50D (1/2” double MC)
C = QLK75 (3/4” single MC)
D = SSBC50 (1/2” EMT Connector)
E = SSBC75 (3/4” EMT Connector)
F = SSBC100 (1” EMT Connector)
9
Connector Top Middle KO
Blank = No Attachment
M = Attachment Present
10
Connector Top Right KO
Blank = No Attachment
R = Attachment Present
* One device adjustable plaster
rings are set at 3/4” raise and can
be adjusted to 11/2” raise.
Two device adjustable plaster rings
are set at 5/8” raise and can be
adjusted to 11/2” raise.
Adjustable plaster ring can only
be used on 4” sq. - 21/8” deep
boxes.
Step 3 - Wiring Devices
11 Wire Configuration
P = Pigtails w/4 Hole 1Wago®
(all receptacles installed w/ground up)
R = Pigtails w/4 Hole Wago
(all receptacles installed w/ground down)
W = No Pigtails Wires Contained Inside
Box (all receptacles installed w/ground up)
Y = No Pigtails Wires Contained Inside Box
(all receptacles installed w/ground down)
M = Pigtails w/ Bare Wire Ends extending from
top KOs, Twist-On Wire Connectors Inside Box
(all receptacles installed w/ground up)
N = Pigtails w/ Bare Wire Ends extending from
top KOs, Twist-On Wire Connectors Inside Box
(all receptacles installed w/ground down)
Note: P, R, M and N configurations not available
if KO connectors are installed on the outlet box
12
Device Type or ArrowLink
Connector Options
Standard Device Type
(see pgs. 34-37)
3 Letter Designator For 1 Device
Two 3 Letter Designators For 2 Different Devices
One 3 Letter Designator For 2 Of The Same Device
ArrowLink Connector Options
(for more information see pgs. 38-39)
New
MCR = ArrowLink Connector, Receptacle/GFCI
MCS = ArrowLink Connector, Single-Pole Switch
Ground Wire
(Pre-installed devices require stranded wire)
Blank = Solid Ground Wire
A = Stranded Ground Wire
N = No Ground Wire
6
Firestop Pad (see pg. 28)
Blank = No Pad
F = Pad Installed
† BB216TCL-1104DA-WAAR
BB216TCL-1104DA-24DA-WAAR
Read safety/installation instruction sheets in packages before use. These products are designed for positioning only. No load rating.