Mains Powered Isolating Signal Converter MVCON The mains powered MVCON Isolating Signal Converter accepts a range of inputs including 4-20mA, thermocouple, RTD and voltage signals and converts them to either voltage or current DC output ■ Wide range of inputs available ■ Full 3-port isolation ■ Optional isolated transmitter supply ■ High accuracy, low cost ■ Zero and span pots for output adjustment ■ Wide range of power supply options 3 Year See VCON for DC version see page 147 Guarantee Options and ordering codes MVCON HL – A A XX – 1 B Input type Options 4-20mA HL A 0-20mA HL B Tx Supply (HL only) Without Tx Supply B 0-30mA 2 sec delay HL C 0-1mA HL D 0-5Vdc HL E 1-5Vdc HL F 1 115Vac 0-10Vdc HL G 2 230Vac 18-26Vdc HL H 500R to 1K 3 wire Pot HL K 1K to 100K 3 wire Pot HL L 0-1A rms HL M 0-5A rms HL N A 4-20mA Type K 0-150˚C TC P B 0-20mA Type K 0-200˚C TC Q C 0-30mA 2 sec delay Type K 0-250˚C TC R D 0-1mA Type K 0-500˚C TC S E 0-5Vdc Type K 0-600˚C TC T F 1-5Vdc Type K 0-1200˚C TC U G 0-10Vdc Type K 0-250/500/1000˚C TC V Type J 0-250˚C TC W Pt100 3 wire ±30˚C RTD 1 Pt100 3 wire 0-50˚C RTD 2 Pt100 3 wire 0-100˚C RTD 3 Pt100 3 wire 0-150˚C RTD 4 Pt100 3 wire 0-200˚C RTD 5 Pt100 3 wire 0-250˚C RTD 6 Pt100 3 wire 0-400˚C RTD 7 Pt100 3 wire 0-100/150/ 200˚C RTD 8 Supply type Output type Other ranges and thermocouple types are available as detailed in the product description, please contact our sales department. PRICE INFORMATION AND ORDERING MVCON Description The MVCON Isolating Signal Converter can accept a wide range of inputs including 4-20mA, thermocouple, RTD and voltage signals. The units produce a high level DC output of either voltage or current. Inputs Standard ranges are shown below – contact Sales for others. MVCONHL for DC/AC Current and Voltage 0-20mA, 4-20mA, 0-10mA into 11Ω/22Ω 0-1V, 0-10V, 1-5V into 100kΩ/1Ω Min and Max full scale ranges are: DC current 0 to 50µA 0 to 10A DC voltage 0 to 100mV 0 to 300V AC current 0 to 100µA rms 0 to 10A rms AC voltage 0 to 200mV rms 0 to 250V rms 2 wire pot 0 to 1kΩ 0 to 1MΩ 3 wire pot 1kΩ 10MΩ Full 3 port isolation is standard but the unit can be supplied as: Non-Isolated Input Only Isolation Output Only Isolation Full 3-Port Isolation The high level (HL) version can be factory configured to accept a current, voltage or potentiometer input and provide a current or voltage output. The Thermocouple (TC) version can be factory configured to accept most thermocouple types and ranges and provide a non-linearised output of current or voltage. The RTD version can be factory configured to accept most types and ranges of RTD (Pt100 Standard) and provide linearised output of current or voltage. Note: For input voltages greater than 30Vac or 60Vdc a divider unit must be specified. MVCONTC for Thermocouples Types E, J, K, N, R, S, T, B non-linearised Ranges 0-250, 0-500, 0-1200˚C (Others available) Cold junction compensation Upscale or downscale t/c burnout options In addition a user configurable version of each type is available to special request allowing several different input/output options to be selected. There is also an isolated transmitter supply option on the HL unit. This provides an isolated 24Vdc supply which can be used to excite any standard transmitter. MVCONRTD for Resistance Thermometers 2 or 3 wire Pt100 or other linearised output Ranges 0-250, 0-500, -100-100˚C (others available) The unit may be powered from a wide range of power supplies, ranging from 110Vac to 240Vac. Outputs DC Current and Voltage 0-20mA, 4-20mA, 0-10mA into a maximum 750Ω 0-1V, 0-10V, 1-5V into a minimum 750kΩ Others available up to a maximum of: Current: 0-20mA. Voltage: 0-15Vdc ▲ 104.5mm 98mm ▲▲ ▲ Dimensions and connections 123 ▲ 456 75mm 7. Process input -ve 8. Process input +ve T/C -ve T/C +ve RTD -ve RTD +ve 9. Trans supply +ve T/C shield RTD 3rd wire 10. Output -ve 12. Output +ve ▲ ▲ 22.5mm ▲ 1. Power input live 3. Power input neutral 789 PRICE INFORMATION AND ORDERING 10 11 12 Specifications Parameter Supply voltage Supply power Input impedance (volt) Input impedance (mA) Volt drop (mA input) Output linearity error Temp coefficient Load resistance error Time constant (10-90%) Operating ambient Relative humidity Isolation voltage see note 1 Surge voltage Notes Min Typ 230Vac 100kΩ 0.02Ω 1MΩ 11Ω 0.2 0.03% Max 2VA 10MΩ 5kΩ 0.25 0.1% ±100ppm/˚C -10ppm/Ω Comments Options: 115Vac or 230Vac 50/60Hz Dependent on range (Typ=10V) Dependent on range (Typ=20mA) At 20mA input 0≤RL ≤750Ω 30ms 0˚C 0% 1kV 55˚C 90% 2.5kV for 50µS Transient of 10kV/µS Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. Accuracy figures based on 24Vdc supply, high level (HL) unit, 4-20mA output with 250Ω load and 20˚C ambient. Device is protected against reverse polarity connection. 1: MVCON-HL does NOT provide safety isolation when the input is connected to the mains. Device incorporates a non-resettable thermal cut-out in the mains input. IMPORTANT: Mains input should be protected by a 100mA anti-surge fuse (T100mA) with a voltage rating of 250Vac and a breaking capacity of 35A at 250Vac placed in series with the live connector.