ACM ANALOG INPUT / OUTPUT FEATURES z z z z z z z z z z Analog Input/Output Modules Voltage Potentiometer Current RTDs and thermocouples Strain gage Accelero ICP Freq => Voltage RMS => DC Etc. … Plug and Play Easy identification with eight colours High accuracy ≥ ± 0,03 % FS typical Insulation ≥ 500Vrms Protected Input/Output Narrow and wide band Fault detection High reliability Very low cost DESCRIPTION The series of analogic modules ACM was developed to answer in a simple way to any type of sensors' conditioning . This simplicity of use was not to the detriment of the quality of the measures because module ACM possesses: z z z z z Galvanic insulation up to 500Vrms Inputs and Outputs protections Metrological characteristics of class > 12 bits 4th order low-pass filters A defect output in case of abnormality on the signal Modules ACM are presented in eight colors with a clear identification to facilitate the maintenance. Modules ACM are mounted on a STB6x2 for a module 8 and a STB658 to form 16 conditioned inputs or outputs. Furthermore, their cost is very attractive. 9 rue Georges Besse – BP 47 – 78330 FONTENAY LE FLEURY – FRANCE Tél.:(33) 1 30 58 90 09 fax:(33) 1 30 58 21 33 http://www.adas.fr ACM SPECIFICATIONS TYPE DC VOLTAGE VERSION - Input range - Input protection - Input resistance RMS/DC modules (FIN = 1 KHz) SINUS - Input range - Coupling - Bandwidth - Accuracy - Linearity - Crest factor CURRENT VERSION - Type - Input resistor - input protection THERMOCOUPLE VERSION - Types - Cold junction compensation - Compensation error - Warn up time - Open-loop detection PLATINIUM SENSOR VERSION (RTD) - Type - Injected current - Linearization (PT100) STRAIN GAGE - Wiring - Supply bridge - Sensibility - Gain ACCELERO ICP - Supply - Coupling - VIN FILTERING - Type - Cutoff frequency ANALOG OUTPUT TO THE SYSTEM - Voltage - Output impedance - Max. current - Accuracy - Stability (t = 25°C) INPUT MODULES From 50mV to 50V FS (see ordering information) ± 100V DC 1MΩ From ± 10 mVeff to ± 50 Veff (see ranges) AC input ZIN = 100 KΩ 40 Hz to 20 KHz (± 1 dB) ± 0,2 % FS (FS to FS/20) ± 0,05 % FS (FS to FS/20) 3 max 0 → 20mA ; 4 → 20mA ; 0 → 40mA ± 2mA; ± 5mA; ± 8mA ; ± 10mA ; ± 20mA ; ± 40mA ≈ 50Ω 24V max J, K, T, E, R, S t° = 25°C : ± 2 °C ∆ t° = 10°C to 40°C : ± 1,5°C 10 mn Yes 3 and 4 wires 1mA Yes α 1 = 0.00385 Bridge 10,000V / 30mA 10mV / V 100 Constant current 4mA / 24V AC Fc (LPF) = 0,1Hz ± 5V FS Low-pass Butterworth 4th order polynomial filter To be defined on ordering this product (see chart) ± 10V FS < 10Ω 5mA ± 0,03 % typ. FS (± 0,06 min) ≥ 20ppm/°C ACM TYPE VOLTAGE VERSION - Levels - Output drive - Output resistance CURRENT VERSION - Levels - Output compliance voltage OTHER - Accuracy - Linearity - Noise - Bandwidth - Output setting time - Stability - Output enable control - Output protection OUTPUT MODULES 0 → 5V ; 0 → 10V ± 5V ; ± 10V 20mA max 0,5Ω 0 → 20mA ; 4 → 20mA ± 20mA ± 10V min ± 0,05 % span ± 0,03 % span 20µA p-p 3 KHz (- 3dB) 100µs 20ppm/°C Security 0V or 0mA Continuous short to ground COMMON SPECIFICATIONS ISOLATION I/O -Type - Rated - IMR LOGIC OUTPUTS - function - output POWER SUPPLY - Consumption PHYSICAL CHARACTERISTICS - Dimensions in mm (H x W x D) - Mounting ENVIRONMENT - Operating temperature - Storage temperature - Relative humidity EUROPEAN NORMS High- voltage breakdown 500Vrms 140dB at 60Kz Detection of out-of-range or loop error condition “open collector”, TTL compatible 0,5W typ. 1W max 55 x 50 x 17 DB 25 TYPE - 10°C to + 70°C - 20°C to + 85°C 90 % (without condensation) EMC - EN 61326 - EN 55011 Class A CE Compliance ROHS - 2002/95/EC ACCESSORIES SHUNT R = 0,01 Ω ou R = 0,1 Ω 10 29/15 CURRENT TRANSDUCER ** (1% ; 50ppm /°C) HOW TO ORDER? HOW TO ORDER? STB/SHUNT/0.XX STB/LA55P/** 10 20 50 10A 20A 50A COMMENT COMMANDER MODULE D'ENTREE ? ACM /IN *** OU ACM/IN***/RMS FREQUENCE DE COUPURE STANDARD F1 = 10Hz F3 = 100Hz TENSION DC BIPOLAIRE F5 = 1KHz TENSION AC RMS VB = ± 50V VF ± 200V VA = ± 20V VD ± 150V V0 = ± 10V VC ± 100V V1 = ± 5V VB = ± 50V V2 = ± 2V V3 = ± 1V VA V0 V1 V2 V3 V4 = ± 500mV V5 = ± 200mV V6 = ± 100mV = ± 20V = ± 10V = ± 5V = ± 2V = ± 1V Ex : ACM/INV0/RMS V7 = ± 50mV V8 = ± 20mV V9 = ± 10mV Ex : ACM/INV4 POTENTIOMETRE VALIM POT = 5,00V P0 = 0 ⇒ 5V P1 = 0 ⇒ 10V Ex : ACM/INP0 FREQUENCE DE COUPURE SPECIALE F6 = 5KHz BOUCLE COURANT BA BB F8 = 20KHz COURANT MOYEN COURANT ELEVE = 0/20mA R = 50Ω (0mA = -10V / 20 mA = + 10V) 10 10A = 4/20mA R = 50Ω 20 20A (4mA = -10V / 20 mA = + 10V) 50 50A BC = ± 20mA R = 50 Ω ( ± 20mA ⇒ 10V) BD = 4/20mA R = 50Ω (4mA = 0V / 20mA = 10V) BE = 0 / 40mA R = 25Ω (0mA = -10V ; 40mA = +10V) BF = ± 8mA R = 50Ω ( ± 8mA ⇒ ±10V) BG = ± 5mA ( ± 5mA ⇒ ±10V) Ex : ACM/INBC RESISTANCE (4 fils) Référence R13 R14 R15 F7 = 10KHz PE 1KΩ 10KΩ 100KΩ Ex : ACM/IN R1X INJ 100µA 10µA 10µA STB/DERIVATION (0,01Ω) + module ACM/IN/V6 ACM/INV9 ACM/INV6/RMS ACM/INV9/RMS DC = ± 10A dc = ± 1A dc AC = ± 10A eff = ± 1A eff BP : 40Hz à 20KHz STB/DERIVATION (0,1Ω) DC ACM/IN/V6 = ± 1A dc ACM/INV9 = ± 100mA dc AC ACM/INV6/RMS = ± 1A eff ACM/INV9/RMS = ± 100A eff STB/LA55P/** + module DC ACM/IN/LA55P/DC AC ACM/IN/LA55P/RMS COMMENT COMMANDER MODULE D'ENTREE? ACM /IN *** THERMOCOUPLES (°C) TYPE J SONDE PLATINIUM A31 ou A41 TYPE K = - 210 / + 370 k3 = - 210 / + 250 J1 = - 210 / + 705 k2 = - 210 / + 484 B31 ou B41 J0 = - 210 / + 1200 k1 = - 210 / + 964 B32 ou B42 k0 = - 210 / + 1372 = - 50 / + 250°C T1 = - 270 / + 250 E2 = - 270 / + 290 D31 ou D41 T0 = - 270 / + 390 E1 = - 270 / + 535 D32 ou D42 E0 = - 270 /+ 1000 L31 ou L41 = - 50 / + 400°C = - 50 / + 800°C = - 50 / + 50°C L32 ou L42 TYPE S 1 = α = 0,385 3 = 3 fils 4 = 4 fils R1 = - 270 / + 960 S1 = - 270 /+ 1030 2 = α = 0,392 R0 = - 270 / + 1650 S0 = - 270 /+ 1768 Ex . : ACM/INB41 F3 = 100Hz Ex . : ACM/INE2 FREQUENCE COUPURE STANDARD F1 = 10Hz F5 = 1KHz Notes : z Ex:ACM/INLM35 IN: +/- 100mV -50 / + 100°C ALP: 10V ; Fc: 1 KHz ACM/INMPX5100 Silicium intégré C32 ou C42 TYPE E TYPE R Ex: ACM/ SG350 Ω Capteur de pression C31 ou C41 TYPE T FONCTIONS SPECIALES = - 50 / + 100°C A32 ou A42 J2 PONT DE JAUGE Les plages thermocouples données ci-dessus sont en valeurs positives PE. C'est aussi possible en valeurs négatives. Ex : Type K = - 6,458mV = - 210°C Frescale MPX5100 series COMMENT COMMANDER MODULE DE SORTIE? ACM/OUT ** ACM/OUT **- I TENSION COURANT VIN = ± 10V VB = ± 40V BA = 0/20mA RLm = 500Ω (- 10V = 0mA ; + 10V = 20mA) VA = ± 20V BB = 4/20mA RLm = 500Ω (- 10V = 4mA ; + 10V = 20mA) V0 = ± 10V BC = ± 20mA RLm = 500Ω (-10V = - 20mA ; +10V = 20mA) V1 = ± 5V BD = 4/20mA RLm = 500Ω (0V = 4mA ; 10V = 20mA) WB = WIDE BAND BE = 0 / 40mA RLm = 200Ω (-10V = 0mA ; +10V = 40mA) Ex : ACM/OUTVA-WB BF = ± 8mA RLm = 1000Ω ( -10V = - 8mA ; − 10V = 8mA) Ex : ACM/OUTBC NB : RLm = R Loop max Haute tension mode commun Version isolement galvanique