TRM006 The TRM-006 is accurate, reliable, and easy to program. Advanced Digital Indicator for a multitude of applications T oho’s TRM-006 is an 1/8 DIN Digital Indicator that has many advanced features, including Peak Hold/Bottom Hold functions and a digital PV filter. Options include RS-485 communications, two programmable alarms, analog retransmission, and a 5V or 12V DC sensor/transmitter power supply. This versatile indicator accepts many kinds of inputs, including eight types of thermocouple, two types of RTD, DC current and voltage. The 4-digit, 15mm-high character LED display is clearly readable both from a distance and in bright light. As always, the TRM-006 comes with a two-year warranty and free technical support throughout the life of the product. TRM-006 BENEFITS: Many kinds of input—thermocouple, RTD, DC current and voltage LED display—bright and easy-to-read 4-digit, 15mm high characters Peak and bottom hold function—stored in non-volatile memory Digital PV filter—reduces unwanted noise Optional RS-485 communications—network up to 31 units Two optional alarm settings—programmable as absolute or hold, with buzzer Analog retransmission—retransmit PV as current/voltage Sensor power supply—built-in 5V or 12V DC available Two-year warranty—protects against manufacturers defects GETEC LTDA. Rondizzoni 1532, Santiago, Chile Tel. (56)2-5548520 Fax (56)2-5548479 www.getec.cl TRM-006 SPECIFICATIONS INPUT Kind of input: Thermocouple: K, J, E, T, R, S, N, W5Re/W26Re RTD: Pt100 DIN, JPt100 Current: 4–20mA DC Voltage: 0–5V, 0–10V, 0–10mV, 1–5V DC Sampling time: 0.5 sec Input resistance: Thermocouple: 1MΩ Min. from +side of terminal Current: 250Ω Min. from A side of terminal Voltage: 500KΩ Min. (1–5V, 0–1V, 0–5V DC) 1MΩ Min. from +side of terminal (0–10V, 0–10mV DC) Bias current: Thermocouple: 0.18µA RTD: 0.2mA Current: 9nA Voltage: ±9nA max (1–5V, 0–1V, 0–5V DC) 0.18µA (0–10mV) External resistance: Thermocouple: 100Ω max including sensor RTD: 5Ω max for one wire Burnout: Thermocouple: Upscale RTD: Upscale Current: Downscale Voltage: “0” for 0–1V, 0–10V, 0–5V DC Downscale for 0–5V DC/ Upscale for 0–10mV DC Digital PV filter: Setting range: 0–99 sec (Time constant filter is OFF at 0) Unit: sec PV holding: Selectable—Non holding, Peak holding, Bottom holding, Peak and Bottom holding PV Correction: -10% to +10% of full scale OPTIONAL FUNCTIONS Alarm AL1, AL2: Sensitivity: 10% of full scale max Output rating: 250V AC, 0.5A, or 125V AC, 1A (resistive load) Relay contact: 1a contact Transfer outputs: Output voltage/current: 1–5V, 0–10V, 0–10mV DC, 4–20mA DC Output resolution: Better than indication Output response time: 600ms max Output accuracy: ±0.3% Sensor drive voltage 5V DC: Load resistance 500Ω Min. Output sensitivity within ±5% 12V DC: Load resistance 1.2KΩ Min. Output sensitivity within ±5% Communication method: Protocol: TOHO’s specification Network: RS-485, Multi-drop 1–31 units Transmission code: ASCII (7-bit without BCC data) Interface method: Transmission line: 2-wire (Tx/Rx) Com speed: 1200, 2400, 4800, 9600, BPS selectable Com distance: 500m max Character: Start bit: 1 bit fixed Stop bit: Selectable, 1 or 2 Data length: Selectable, 7 or 8 Parity bit: None, even or odd Check BCC: With or without—selectable Communication address: Setting from 1–99 MODEL CONFIGURATION TRM-006 DISPLAY Indication: PV display: 4-digit, 15mm high, green Mode display: 1-digit, 8mm high, red AL1: Red LED, for alarm 1 operation AL2: Red LED, for alarm 2 operation COM: Green LED for communications operation MIN: Red LED for bottom value MAX: Red LED for peak value Indicating accuracy: Thermocouple: ±0.3% of full scale + 1 digit or ±3°C (±6°F) RTD: ±0.3% of full scale + 1 digit or ±0.9°C (±1.8°F) Current/Voltage: ±0.3% of full scale + 1 digit Setting: Key operation for all setting Lock Method: 3 modes (no lock, all lock, parameter display lock) Memory element: EEPROM Isolation between input and output: Isolation between each output and digital circuit No Isolation between input and digital circuit Power supply: 85–264V AC, 50/60 Hz, 24V AC/DC ±10% (optional) Power consumption: 10VA max at 264V AC Ambient temperature/humidity: 0–55°C, 35–85% RH (no dew) Insulation resistance: Between ground terminal and power/input terminal 20MΩ at 500V DC Dielectric strength: Between ground terminal and power or input terminal 1000 VAC for 1 min Dimensions: 1/8 DIN 48(H) x 96(W) x 91(D)mm Mounting method: Panel mounting; cut-out size: 92(W) x 45(H)mm Wiring method: Screw-down type INPUT Thermocouple RTD Voltage 1–5V Current 4–20mA Voltage 0–1V Voltage 0–10V Voltage 0–10mV Voltage 0–5V CODE 0 1 2 3 4 5 6 7 OPTIONS* CODE Alarm Relay 1 A Alarm Relay 2 B Buzzer C Transfer output: 1–5V F 0–10V G 0–10mV H 4–20mA I RS-485 Communications M Voltage for sensor drive 5V DC L Voltage for sensor drive 12V DC Q * You may select a maximum of 5 options but when “L” or “Q” is selected “M”, “F”, “G”, “H”, or “I” is not available POWER SUPPLY 85–264V AC (standard) 24V AC/DC CODE 24 ay 2 GETEC LTDA. Rondizzoni 1532, Santiago, Chile Tel. (56)2-5548520 Fax (56)2-5548479 www.getec.cl