ATDR - Brews Supply

advertisement
AMP-TRAP 2000®
ATDR
TIME DELAY / CLASS CC
THE BEST PROTECTION FOR TODAY’S
SMALL MOTORS.
Amp-trap 2000® ATDR small-dimension fuses can
provide IEC Type 2 “no damage” protection to your
facility’s increasingly sensitive branch circuit components and small motors – minimizing the risk of
fault-related damage. ATDR Class CC fuses deliver
the best time delay characteristics in their class with
excellent cycling ability for small motor loads.
Features/Benefits
Time delay for motor starting inrush currents without
nuisance opening
Highly current limiting for low peak let-thru current
Improved cycling ability for frequent motor
starts/stops without nuisance fuse opening
Rejection-style design prevents replacement errors
(when used with recommended fuse blocks)
High-visibility orange label ensures instant recognition,
simplifies replacement
Metal-embossed date and catalog number
for traceability and lasting identification
Fiberglass body provides dimensional stability in harsh
industrial settings
High-grade silica filler ensures fast arc quenching
and optimum current limitation
HIGHLIGHTS:
APPLICATIONS:
Time Delay
Best Choice for Small
Motor Protection
Highly Current-Limiting
AC & DC Rated
Small Motors
Contactors
Lighting, Heating &
General Loads
Branch Circuit Protector
Ratings
A C : 1/4 to 30A
600VAC, 200kA I.R.
D C : 1/4 to 30A
300VDC, 100kA I.R.
A 13
Approvals
UL Listed to
Standard 248-4
CSA Certified to
Standard C22.2
No. 248.4
DC Listed to
UL Standard 198L
A
AMP-TRAP 2000®
TIME DELAY / CLASS CC FUSES
ATDR
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1/4
1/2
8/10
1
1-1/8
1-1/4
1-4/10
ATDR1/4
ATDR1/2
ATDR8/10
ATDR1
ATDR1-1/8
ATDR1-1/4
ATDR1-4/10
1-1/2
1-6/10
1-8/10
2
2-1/4
2-1/2
2-8/10
ATDR1-1/2
ATDR1-6/10
ATDR1-8/10
ATDR2
ATDR2-1/4
ATDR2-1/2
ATDR2-8/10
3
3-2/10
3-1/2
4
4-1/2
5
5-6/10
ATDR3
ATDR3-2/10
ATDR3-1/2
ATDR4
ATDR4-1/2
ATDR5
ATDR5-6/10
6
6-1/4
7
7-1/2
8
9
10
ATDR6
ATDR6-1/4
ATDR7
ATDR7-1/2
ATDR8
ATDR9
ATDR10
12
15
17-1/2
20
25
30
ATDR12
ATDR15
ATDR17-1/2
ATDR20
ATDR25
ATDR30
Dimensions
Small Motor Fuse Protection,
600 Volts AC or Less
MOTOR
FULL LOAD
AMPERES
.71 - .89
.90 - 1.19
1.20 - 1.34
1.35 - 1.79
1.80 - 2.25
2.26 - 2.69
2.70 - 2.90
2.91 - 3.20
3.21 - 3.75
3.76 - 4.50
4.51 - 5.34
5.35 - 5.69
5.70 - 6.70
6.71 - 7.79
7.80 - 8.88
8.89 - 11.1
11.2 - 13.3
13.4 - 15.2
ATDR RATING*
MINIMUM
NORMAL
DUTY
DUTY
1-1/4
1-6/10
2
2-1/2
3
4
4
5
5
6
8
10
12
12
15
17-1/2
20
25
Recommended Fuse Blocks for
Class CC Fuses
1-6/10
2
2-1/2
3
4
5
6
6
7
8
10
12
12
15
17-1/2
20
25
30
CATALOG NUMBER
Screw
ULTRASA F E “ Connector
Number Indicating w/ Double
of
Fuse
Quick
Poles
Holder
Connects
ADDER
1
2
3
* The National Electrical Code allows time-delay Class CC fuses to be
sized at up to 400% (maximum) of motor FLA, if needed.
A 14
USCC1I
USCC2I
USCC3I
30310R
30311R
30312R
30313R
Pressure
Plate
Connector
Copper
w/ Double
Box
Quick
Connects Connector
30320R
30321R
30322R
30323R
30350R
30351R
30352R
30353R
AMP-TRAP 2000®
TIME DELAY / CLASS CC FUSES
ATDR
ATDR1/4 to 30
Current in Amperes
Melting Time — Current Data, 600V Fuses
A
Time in Seconds
Maximum Instantaneous Peak Let-Thru Amperes
Peak Let-Thru Current Data — ATDR1/4 to 30, 600 Volts AC
Available Current in RMS Symmetrical Amperes
A 15
USCC & USM
TM
24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS
ULTRASAFE MODULAR FUSE HOLDERS
Ferraz Shawmut ULTRASAFETM modular 24, 48 and
600 volt Fuse Holders introduce a new level of
safety for Class CC (USCC) and Midget 1-1/2" x
13/32" (USM) as well as DC rated fuses up to 30
amperes. ULTRASAFE holders qualify as “finger safe”
under IEC and DIN standards to an IP20 grade of
protection, including fuse changing (with the flick of
a finger). ULTRASAFE holders are available in 1, 2, 3
or 4 poles, with or without blown-fuse indicators in
each pole. AC indicators are orange and DC are
red. The multi-pole units can also be made up by
ordering pin-tie handles for field assembly.
ULTRASAFE holders save up to 15% mounting
space and any combination can be snapped onto
35mm DIN rail for extra savings in panel building
time. ULTRASAFE holders with Class CC fuses
chosen for Type “2” protection give one of the safest
protection packages in the industry. Ultrasafe body
material is tough and durable polyamide, with
exceptional insulating properties.
Ratings
HIGHLIGHTS:
APPLICATIONS:
All circuits up to
Finger Safe
600 volts for motors,
Optional Indicator Lights
control circuits,
DIN Rail Mount
transformers, etc.
Compact Footprint
Non-load disconnect
Quick, Easy Fuse Change 12, 24 and 48 volt
DC circuits
600VAC, 30A
Min. voltage to operate
indicator light:
90VAC
[Less than 0.7 mA
leakage current at 600V]
Special Indicator for
24VDC, 30A
Special Indicator for
48VDC, 30A
Withstand rating:
Class CC 200kA I.R.
Midget Fuse 100kA I.R.
RECOMMENDED FUSE USAGE
USCC . . . . . . . . . . . . . . .use with ATDR*, ATMR, ATQR
USM . . . . . . . . . . . . . . . .use with ATQ, ATM*, A6Y-2B, A25Z-2,
TRM, OTM, A13X-2, GFN, GGU, A60Q-2
* Recommended for DC Applications
H2
Approvals
All Ultrasafe Fuse Holders
meet the requirements of
UL512
UL Listed
Class CC
Guide IZLT, File E52283
UL Recognized
Component
Midget
Guide IZLT2, File E52283
CSA Certified
Class CC & Midget
C22.2, Class 6225
File 32169
IEC 269
690VAC, 32A
Midget version only.
USCC & USM
TM
24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS
For use with Class CC Fuses
CATALOG NO.
DESCRIPTION
USCC1
USCC1I
USCC2
USCC2I
USCC3
USCC3I
USCC3IN
USCC3N
USCC4
USCC4I
1 pole
1 pole with indicator
2 pole
2 pole with indicators
3 pole
3 pole with indicators
3 pole with indicators and a 4th neutral pole
3 pole with a 4th neutral pole
4 pole
4 pole with indicators
For use with Midget (1-1/2” x 13/32”) Fuses
USM1
USM1I
USM2
USM2I
USM3
USM3I
USM3IN
USM3N
USM4
USM4I
1 pole
1 pole with indicator
2 pole
2 pole with indicators
3 pole
3 pole with indicators
3 pole with indicators and a 4th neutral pole
3 pole with a 4th neutral pole
4 pole
4 pole with indicators
Neutral Link Pole
USN
1 Pole with Integral Neutral Link
Accessories
USPTH2
USPTH3
USPTH4
Pin-tie handle for 2 poles
Pin-tie handle for 3 poles
Pin-tie handle for 4 poles
Special Indicator Options For use with
Low Voltage DC Rated Class CC & Midget Fuses
PART
NUMBER
INDICATOR
TYPE
OPERATING
LEAKAGE
VOLTAGE
CURRENT
USM1I-DC24
USM1I-DC24P
USM1I-DC48
USCC1I-DC24
USCC1I-DC48
LED
LED
LED
LED
LED
12 to 24 VDC
20 to 24 VDC
35 to 48 VDC
12 to 24 VDC
35 to 48 VDC
10mA max.(@24vdc)
1mA max.(@24vdc)
10mA max.(@48vdc)
10mA max.(@24vdc)
10mA max.(@48vdc)
Dimensions
DIMENSION
mm
In
A
B
C
D
17.5
35.0
52.5
70.0
0.69
1.38
2.07
2.76
E
F
G
H
78.0
2.5
78.0
59.0
3.07
0.10
3.07
2.32
I
J
K
42.5
5.0
45.0
1.67
0.20
1.77
Terminal screws: Phillips/slot head
Suggested screw torque: 14.75 in-lbs.
Connector type: Pressure plate
Wire range: #6 to #14 (solid/stranded Cu)
Load-break disconnect: No
H3
H
TRI-ONIC®
TRM
1-1/2" X 13/32"
Tri-onic TRM time-delay midget fuses are
rated 250 volts AC and are offered in 36
ampere ratings from 1/10A to 30A.
They have 12 seconds time delay at 200%
rating to provide supplemental protection
of small motors, small transformers and
other high inrush loads, plus many other
250 volt applications. (Not for Branch
Circuit Protection).
HIGHLIGHTS:
APPLICATIONS:
®
Time Delay
®
250 VAC Rated
®
®
®
®
MIDGET FUSES
Features / Benefits
® Numerous ratings for a wide variety of
applications
® 250VAC rating in all sizes up to 30A
® Time delay for circuits with high inrush
currrent
® Can be used with ULTRASAFE™ fuse holders
C
Approvals
Ratings
® AC: 1/10 to 30A
250VAC, 10kA I.R.
Small Motors
Small Transformers
Lighting Circuits
Control Circuits
® UL Listed to
Standard 248-14
® CSA Certified to
Standard C22.2 No. 248.14
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
1/10
15/100
2/10
3/10
4/10
1/2
CATALOG
NUMBER
TRM1/10
TRM15/100
TRM2/10
TRM3/10
TRM4/10
TRM1/2
AMPERE
RATING
6/10
8/10
1
1-1/8
1-1/4
1-4/10
CATALOG
NUMBER
TRM6/10
TRM8/10
TRM1
TRM1-1/8
TRM1-1/4
TRM1-4/10
AMPERE
RATING
1-6/10
1-8/10
2
2-1/4
2-1/2
2-8/10
CATALOG
NUMBER
TRM1-6/10
TRM1-8/10
TRM2
TRM2-1/4
TRM2-1/2
TRM2-8/10
AMPERE
RATING
3
3-2/10
3-1/2
4
4-1/2
5
Melting Time — Current Data 1/10 - 3-1/2 Amperes, 250 Volts AC
CATALOG
NUMBER
TRM3
TRM3-2/10
TRM3-1/2
TRM4
TRM4-1/2
TRM5
AMPERE
RATING
5-6/10
6
6-1/4
7
8
9
CATALOG
NUMBER
TRM5-6/10
TRM6
TRM6-1/4
TRM7
TRM8
TRM9
AMPERE
RATING
10
12
15
20
25
30
CATALOG
NUMBER
TRM10
TRM12
TRM15
TRM20
TRM25
TRM30
Time in Seconds
Time in Seconds
Melting Time — Current Data 4 - 30 Amperes, 250 Volts AC
Current in Amperes
Current in Amperes
C5
ONE TIME
OTM
1-1/2" X 13/32"
One-time OTM midget fuses provide lowcost protection for 250 volt AC general
purpose lighting, heating, control circuits,
etc. where time delay is not required.
(Not for Branch Circuit Protection).
HIGHLIGHTS:
APPLICATIONS:
®
Fast Acting
®
®
250VAC Rated
MIDGET FUSES
Features / Benefits
® Low cost and fully rated for economy
without compromise
® Can be used with ULTRASAFE™ fuse holders
Approvals
Ratings
Supplemental protection
of circuits up to
250VAC and 10kA
® AC: 1 to 30A
250VAC, 10kA I.R.
® UL Listed to
Standard 248-14
® CSA Certified to
Standard C22.2 No. 248.14
Melting Time — Current Data 1-30 Amperes, 250 Volts AC
Standard Fuse Ampere
Ratings, Catalog Numbers
Time in Seconds
AMPERE
RATING
1
2
3
4
5
6
8
10
15
20
25
30
Current in Amperes
C6
CATALOG
NUMBER
OTM1
OTM2
OTM3
OTM4
OTM5
OTM6
OTM8
OTM10
OTM15
OTM20
OTM25
OTM30
MIDGET & CLASS CC
600 VOLT / FUSE BLOCKS
600 VOLT MIDGET
AND CLASS CC FUSE BLOCKS
Ferraz Shawmut Midget Fuse Blocks accommodate
all 30 ampere 1-1/2" x 13/32" midget fuses. Class
CC Fuse Blocks accommodate all 30 ampere Class
CC fuses. A choice of box, screw, or pressure-plate
connectors fit a wide range of stranded or solid
copper wire. Insulators are glass-filled polycarbonate
(GFPC) with verified dielectric strength in excess of
2500V. Fuse blocks feature a unique adder block
which can be snapped onto 1-, 2- or 3-pole blocks
to form multi-pole segmented blocks of as many
poles as desired. All fuse clips are made of high
conductivity tin-plated copper alloy.
Ratings
Approvals
® 600VAC: 30A
® Withstand rating: 200kA
using screw, pressure
plate or box connections,
10kA using quick
connects
RECOMMENDED FUSE USAGE
Midget Fuse Block . . . . .use with ATQ, ATM, A6Y-2B, A25Z-2,
TRM, OTM, A13X-2, GFN, GGU, A60Q-2
® Temperature/
flammability:
GFPC insulators
rated 125˚C,
94V-0 flammability
Class CC Fuse Block . . . .use with ATDR, ATMR, ATQR
® All fuse blocks meet
the requirements of
UL Std. 512
Midget Block
® UL Recognized
Component
Guide IZLT2, File E52283
® CSA Certified
Class 6225, File 32169
Class CC Block
® UL Listed,
Guide IZLT, File E52283
® CSA Certified
Class 6225, File 32169
Clip & Connector Types
30A MIDGET/CC
COPPER BOX
CONNECTOR
SCREW WITH
DOUBLE QUICKCONNECTS
PRESSURE
PLATE WITH
DOUBLE QUICKCONNECTS
H 13
PRESSURE
PLATE WITH
DOUBLE
QUICKCONNECTS
(CLASS CC
REJECTION
END)
H
MIDGET & CLASS CC
Adder
1 Pole
2 Pole
600 VOLT / FUSE BLOCKS
3 Pole
Recommended mounting screws for all Midget and Class CC fuse blocks: #8 (.164" dia.)
600 Volt, 30A Midget and Class CC Fuse Blocks
CONNECTOR
TYPE
WIRE RANGE
Screw w/double
quick connects
at both ends
Cu
#10-14
Pressure plate
(sems) w/double
quick connects
at both ends
Cu
#10-14
Copper
box
Cu
#6-14
POLES*
MIDGET
ADDER
1
2
3
4
30310
30311
30312
30313
30314
ADDER
1
2
3
4
30320
30321
30322
30323
30324
ADDER
1
2
3
4
30350
30351
30352
30353
30354
CATALOG NUMBER
TYPE OF FUSE
LISTING
CLASS CC
®
&
CSA
®
&
CSA
®
&
CSA
LISTING
CONNECTOR
TORQUE
In - lb
30310R
30311R
30312R
30313R
30314R
UL
&
CSA
20
30320R
30321R
30322R
30323R
30324R
UL
&
CSA
20
30350R
30351R
30352R
30353R
30354R
UL
&
CSA
35
Note: To convert Midget or Class CC adder pole to single pole, use end barrier #U09301.
* Available in any number of poles. Replace last digit in Catalog Number with number of poles needed.
Example: 303112 is a 12-pole screw/double QC connector Midget Fuse Block.
Total width of N poles = (N x .76) + .08 inches. 12 poles = (12 x .76") + .08" = 9.20".
Note: Please see fuse block accessories (H 63) for information regarding fuse block accessories; DFC3M, DFC3LP or DRM.
H 14
GPM SERIES
PANEL MOUNT / FUSE HOLDERS
GPM PANEL MOUNT FUSE HOLDERS
Ferraz Shawmut GPM Panel Mount Fuse Holders
are in sizes to accommodate 5mm x 20mm, 1/4"
x 1-1/4", Class CC and Midget (1-1/2" x 13/32")
fuses. All 30A holders have glass-filled polyester
insulators for extra dependability and trouble-free
installation. Patented design allows same body to
accept screw or bayonet knob. Flange design allows
front or rear mounting. The 10A and 15A holders are
for front mounting only.
Approvals
® GPM-A, GPM-G:
UL Recognized, Guide IZLT2, File E118864
CSA Certified, Class 908501, File AP82191
® All others:
UL Recognized, Guide IZLT2, File E52283
CSA Certified, Class 6225, File 32169
RECOMMENDED FUSE USAGE
GPM Fuse Holders will accommodate these Ferraz Shawmut fuses:
GPM-A: GGM, GGA, GSC
GPM-G: GSA, GDL, GGC, GSB, GDG, GAB
GPM-SRR, GPM-BRR, GPM-WTR: ATQR, ATDR, ATMR
GPM-SRR90, GPM-BRR90, GPM-WTR90: ATQR, ATDR, ATMR
ATQ, ATM, TRM, OTM, GGU,
GPM-S, GPM-B, GPM-WT:
GPM-S90, GPM-B90, GPM-WT90: A13X-2, A25Z-2, A60Q-2, A6Y-2B
H
}
Figure 1
Figure 2
Catalog Numbers & Descriptions
Figure 3
CATALOG NO.
FIG.
CAP TYPE
AMPS
VOLTS
FUSE TYPE
GPM-A
GPM-G
GPM-S
GPM-S90
GPM-SRR
GPM-SRR90
1
2
3
4
3
4
Screw Knob
Screw Knob
Screw Knob
Screw Knob
Screw Knob
Screw Knob
10
15
30
30
30
30
250
250
600
600
600
600
5mm x 20mm
1/4" x 1-1/4"
1-1/2" x 13/32"
1-1/2" x 13/32"
Class CC
Class CC
TERMINAL TYPE
Solder
Solder
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
GPM-B
GPM-B90
GPM-BRR
GPM-BRR90
3
4
3
4
1/4 Turn Bayonet Knob
1/4 Turn Bayonet Knob
1/4 Turn Bayonet Knob
1/4 Turn Bayonet Knob
30
30
30
30
600
600
600
600
1-1/2" x 13/32"
1-1/2" x 13/32"
Class CC
Class CC
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
GPM-WT
GPM-WT90
GPM-WTR
GPM-WTR90
3
4
3
4
Water-tight Screw Knob
Water-tight Screw Knob
Water-tight Screw Knob
Water-tight Screw Knob
30
30
30
30
600
600
600
600
1-1/2" x 13/32"
1-1/2" x 13/32"
Class CC
Class CC
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
1/4" Quick-connect/Solder
1/4" Quick-connect/Solder, Right Angle
H 19
Figure 4
GPM-SERIES
PANEL MOUNT / FUSE HOLDERS
GPM-SERIES
RF Shielded/watertight panel mount for 3AG fuses.
Radio frequency shielded fuseholders eliminate
possible transmission or reception of RF signals
through the hole in the chassis in which the
fuseholder is mounted. These fuseholders comply
with the watertight construction requirement of
MIL-F-19207 and the Shock-Safe requirements of
IEC 65 and 257. A rubber O-ring and conductive
gasket maintain RF shielding and watertight
construction.
Catalog Numbers & Descriptions
CATALOG NO.
BRASS SHIELDING.
CAP FINISH
GPM-RFN
GPM-RFB
NICKEL PLATED
DULL BLACK
H 20
GPM SERIES
PANEL MOUNT / FUSE HOLDERS
INTERNATIONAL SHOCK-SAFE
PANEL MOUNT TYPE FUSES
A complete selection of styles satisfy a wide variety
of fuseholder design needs. Designed to eliminate the
possibility of electrical shock, as defined in IEC
standards 65 and 127. The Universal fuseholder body
will accept 3AG, 5x20mm, and 2AG fuse sizes
depending on knob selected. Permits inventory
reduction of bodies and provides knob interchange
versatility. Anti-tease feature eliminates circuit
interruption when knob is accidentally depressed.
Five fuseholder types assure design flexibility.
Available with two knob styles – screwdriver slot or
fingertip. Available in two terminal styles – dual
purpose for soldering or 3/16" NEMA quick connect;
and 1/4" NEMA/DIN quick connect. Quick fuse size
identification is provided with color-coded letters on
fingergrip knob and color-coded screwdriver slot
knobs.
Specifications
Electrical: Insulation Resistance: 10,000 Megohm minimum at 500 VDC.
Contact Resistance: Less than .005 ohms average at currents up to 1 ampere.
Mounting: Threaded styles withstand 15 in.-lb. mounting torque.
Low profile and High profile panel thickness: .032" min./.310" max.
Quick mount panel thickness: .012" min./.360" max.
Rear mount panel thickness: .012" min./.260" max.
Molded Parts: Body material: Black glass-filled thermoplastic (UL 94VO)
Knob material: Grey, blue or black glass-filled thermoplastic (UL 94V0).
Hex Nut Material: Black glass-filled thermoplastic.
Knob: Finger-Grip, Fuse Extractor type or Screwdriver Slot, Fuse
Extractor type with plated copper alloy contact clips. Spring loaded,
locking mechanism provides anti-tease feature and will not vibrate loose.
Terminals: Copper alloy. Tin-plated. Three styles available. A .187" dual
purpose terminal accepts wire for soldering or a Quick-Connect receptacle.
.187" terminal for NEMA Quick-Connect and .250" terminal for NEMA/DIN
Quick-Connect available.
Ambient Temperature: -40ºC to +85ºC.
Hardware: Threaded style fuseholders are supplied with thermoplastic
hex nut unassembled. Quick Mount style fuseholders are supplied with a
push-on type retaining nut, black oxide finish, unassembled.
H 21
APPROVALS
CSA
SEMKO
VDE
3AG
20A 250V
20A 250V
6.3A 250V
10A 250V
5x20mm
10A 250V
10A 250V
10A 250V
10A 250V
2AG
10A 250V
10A 250V
-
H
GPM SERIES
PANEL MOUNT / FUSE HOLDERS
Ordering Information:
Cap Suffix: -020
/
Example:
Body Suffix: -010
GPM - A LS 7
Fuse Size
Style
Terminals
M
2AG-.177" x .570"
LF
Low Profile Body, Black Fingergrip Knob
1
3/16" (Rt. Angle) Dual Purpose Solder/QC
G
3AG-.250" x 1.250"
RF
Rear Mount Body, Black Fingergrip Knob
Fingergrip Knob: 2AG-Blue Letters
3AG-White Letters
5x20mm-Red Letters
2
3/16" (Straight) Dual Purpose Solder/QC
HS
High Profile Body
Screwdriver Slot Knob
4
3/16" (Straight) NEMA/QC
LS
Low Profile Body
Screwdriver Slot Knob
7
1/4" (Rt. Angle) NEMA/DIN QC
QS
Quick Mount Body
Screwdriver Slot Knob
Screwdriver Slot Knob: 2AG-Blue Knob
3AG-Grey Knob
5x20mm-Black Knob
8
1/4" (Straight) NEMA/DIN QC
A
5 x 20mm-.197" x 787"
3
3/16" (Rt. Angle) NEMA/QC
To Order Knob Only:
FUSE
SIZE
FINGERGRIP KNOB
PART NUMBER
SCREWDRIVER SLOT KNOB
PART NUMBER
2AG
3AG
5x20mm
GPM-MLF1-020
GPM-GLF1-020
GPM-ALF1-020
GPM-MLS1-020
GPM-GLS1-020
GPM-ALS1-020
To Order Body Including Nut(s) Only:
TERMINAL
STYLE
BOTTOM
TERMINAL
LOW PROFILE BODY
HIGH PROFILE BODY
REAR MOUNT BODY
QUICK MOUNT BODY
Part Number***
Part Number
Part Number
Part Number
3/16" Dual Purpose
3/16" Dual Purpose
3/16" NEMA QC
3/16" NEMA QC
1/4" NEMA/DIN QC
1/4" NEMA/DIN QC
(Rt. Angle)
(Straight)
(Rt. Angle)
(Straight)
(Rt. Angle)
(Straight)
GPM-ALF1-010
GPM-ALF2-010
GPM-ALF3-010
GPM-ALF4-010
GPM-ALF7-010
GPM-ALF8-010
GPM-AHS1-010
GPM-AHS2-010
GPM-AHS3-010
GPM-AHS4-010
GPM-AHS7-010
GPM-AHS8-010
GPM-ARF1-010
GPM-ARF2-010
GPM-ARF3-010
GPM-ARF4-010
GPM-ARF7-010
GPM-ARF8-010
GPM-AQS1-010
GPM-AQS2-010
GPM-AQS3-010
GPM-AQS4-010
GPM-AQS7-010
GPM-AQS8-010
*** Low profile body will accept either Fingergrip or Screwdriver Slot Knob.
Note: Consult factory for ordering
combined packages with knob and body.
H 22
DFC3M/DFC3LP/DRM
FUSE BLOCK ACCESSORIES
DFC3M SAFETY PULLER PROTECTS PERSONNEL,
COVERS LIVE PARTS
The DFC3M Safety Puller is intended to hold and safely enclose
1-1/2" x 13/32" Midget or Class CC fuses for insertion or removal
from fuse clips, making fuse installation easy and safe without the
use of a standard fuse puller. The DFC3M is made of clear
polycarbonate, so the fuse can be identified when installed in a 303
series fuse block.
DFC3LP SAFETY PULLER HOLDS FUSE, PROTECTS
PERSONNEL AND SAVES SPACE
The DFC3LP holds and safely encloses 1-1/2" x 13/32" Midget or
Class CC fuse, similar to the DFC3M, but with a lower profile in
height so it takes less room where space is restricted. The DFC3LP
is made of clear polycarbonate so the fuse can be seen after
installation in a fuse block such as the Ferraz Shawmut 303 series.
DRM ADAPTS 303 SERIES MIDGET AND CLASS CC
FUSE BLOCKS TO DIN RAIL
The DIN rail adapter, DRM, provides quick mounting for all Ferraz
Shawmut 303 Series Midget and Class CC fuse blocks to all
symmetrical 35mm DIN or asymmetrical 32mm “G” rail. A DRM
adapter is attached to each pole with the screw provided. The DRM
is molded of black polycarbonate and is mounted or dismounted
from the rail simply by depressing the finger pull.
H 62
AMP-TRAP 2000®
ATQR
TIME DELAY / CLASS CC
TAKE CONTROL OF FAULT CURRENTS HEADED
FOR YOUR CONTROL TRANSFORMER
ATQR small-dimension fuses feature time delay
characteristics ideally suited for the high inrush
currents of control transformers, solenoids, and
similar inductive loads. The newest member of our
Amp-trap 2000® family of fuses - ATQR fuses
provide superior protection for the branch circuits
of electrical distribution systems.
Features/Benefits
® Time delay for control transformer inrush loads without
nuisance opening
® Highly current limiting for low peak let-thru current
® Rejection-style design prevents replacement errors
(when used with recommended fuse blocks)
® High-visibility orange label ensures instant recognition,
and simplifies replacement
® Metal-embossed date and catalog number
for traceability and lasting identification
® Fiberglass body provides dimensional stability in harsh
industrial settings
® High-grade silica filler ensures fast arc quenching and
high current limitation
HIGHLIGHTS:
APPLICATIONS:
®
®
Time Delay
® Best Choice for Small
Transformer Protection
® Most Current-Limiting
Ratings
Control Transformers
® Solenoids
® Inductive Loads
® Lighting, Heating &
General-purpose Loads
A 16
® AC: 1/10 to 30A
600VAC, 200kA I.R.
Approvals
® UL Listed to
Standard 248-4
® CSA Certified to
Standard C22.2
No. 248.4
AMP-TRAP 2000®
TIME DELAY / CLASS CC FUSES
ATQR
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1/10
1/8
15/100
3/16
2/10
1/4
3/10
4/10
1/2
6/10
3/4
ATQR1/10
ATQR1/8
ATQR15/100
ATQR3/16
ATQR2/10
ATQR1/4
ATQR3/10
ATQR4/10
ATQR1/2
ATQR6/10
ATQR3/4
8/10
1
1-1/8
1-1/4
1-4/10
1-1/2
1-6/10
1-8/10
2
2-1/4
2-1/2
ATQR8/10
ATQR1
ATQR1-1/8
ATQR1-1/4
ATQR1-4/10
ATQR1-1/2
ATQR1-6/10
ATQR1-8/10
ATQR2
ATQR2-1/4
ATQR2-1/2
2-8/10
3
3-2/10
3-1/2
4
4-1/2
5
5-6/10
6
6-1/4
7
ATQR2-8/10
ATQR3
ATQR3-2/10
ATQR3-1/2
ATQR4
ATQR4-1/2
ATQR5
ATQR5-6/10
ATQR6
ATQR6-1/4
ATQR7
7-1/2
8
9
10
12
15
17-1/2
20
25
30
ATQR7-1/2
ATQR8
ATQR9
ATQR10
ATQR12
ATQR15
ATQR17-1/2
ATQR20
ATQR25
ATQR30
Recommended ATQR Class CC Primary Fuses For
Single Phase Control Transformers
TRANS
VA
25
50
75
100
150
200
250
PRIMARY
VOLTS
FLA
600
0.04
480
0.05
240
0.10
208
0.12
120
0.21
600
0.08
480
0.10
240
0.21
208
0.24
120
0.42
600
0.13
480
0.16
240
0.31
208
0.36
120
0.63
600
0.17
480
0.21
240
0.42
208
0.48
120
0.83
600
0.25
480
0.31
240
0.63
208
0.72
120
1.25
600
0.33
480
0.42
240
0.83
208
0.96
120
1.67
600
0.42
480
0.52
240
1.04
208
1.2
120
2.08
ATQR
AMPS
1/10
1/10
2/10
1/4
4/10
1/4
1/4
4/10
1/2
6/10
1/4
3/10
1/2
3/4
1
3/10
4/10
6/10
1
1-1/2
1/2
1/2
1
1-1/2
2-1/2
1/2
6/10
1-1/2
2
3
6/10
1-1/8
2
3
4*
TRANS
VA
300
500
750
1000
1500
2000
3000
5000
PRIMARY
VOLTS
FLA
600
0.50
480
0.63
240
1.25
208
1.44
120
2.5
600
0.83
480
1.04
240
2.08
208
2.40
120
4.17
600
1.25
480
1.56
240
3.13
208
3.61
120
6.25
600
1.67
480
2.08
240
4.16
208
4.81
120
8.33
600
2.50
480
3.13
240
6.25
208
7.21
120
12.5
600
3.33
480
4.17
240
8.33
208
9.62
600
5.00
480
6.25
240
12.5
600
8.33
480
10.4
ATQR
AMPS
1-1/8
1-1/2
2-1/2
3
5*
1-1/2
2
4*
6*
10*
2-1/2
3
7*
8*
15*
3
4*
10*
12*
20*
5*
7*
10
20*
25*
8*
10*
20++*
20++*
12+*
15+*
30++*
20++*
25+*
A
Dimensions
Recommended Fuse Blocks for Class CC Fuses
Number
of
Poles
ADDER
1
2
3
Screw
ULTRASA F E “
Indicating with Double
Quick
Fuse
Connects
Holder
USCC1I
USCC2I
USCC3I
Pressure Plate
with Double
Quick
Connects
Copper
Box
Connector
30320R
30321R
30322R
30323R
30350R
30351R
30352R
30353R
30310R
30311R
30312R
30313R
Primary fuses - If primary FLA is less than 2 amps, fuse may be 300%
max. (500% for motor control). If primary FLA exceeds 2 amps but is
less than 9 amps, fuse may not exceed 167% of primary FLA unless
secondary protection is used, when it may be increased to 250%. Fuse
sizes shown are based on approx. 40 x FLA for .01 sec.
* Secondary protection is required for these ratings.
+ Fuse will withstand 30 x FLA for .01 second
++ Fuse will withstand 25 x FLA for .01 second
A 17
AMP-TRAP 2000®
TIME DELAY / CLASS CC FUSES
ATQR
Current in Amperes
Melting Time — Current Data, 600V Fuses
ATQR1/8 to 30
Time in Seconds
Max. Instantaneous Peak Let-Thru Current
Peak Let-Thru Current Data — ATQR1/8 to 30, 600 Volts AC
Available Current in RMS Sym. Amperes
A 18
AMP-TRAP®
ATQ
1-1/2" X 13/32"
Amp-trap ATQ midget time-delay fuses
are rated a full 500 volts AC with 42
ampere ratings from 1/10 to 30A. They
are an excellent choice for supplemental
protection of circuits up to 30A where the
available short circuit current does not
exceed 10,000A. (Not for Branch Circuit
Protection).
MIDGET FUSES
Features / Benefits
® Numerous ratings for a wide variety of
applications up to 500VAC
® Time Delay (12 seconds at 200% rating) for
circuits with high inrush current
® Can be used with ULTRASAFE™ Fuseholders
HIGHLIGHTS:
APPLICATIONS:
Ratings
Approvals
®
®
® AC: 1/10 to 30A
500VAC, 10kA I.R.
® UL Listed to
Standard 248-14
Time Delay
Supplemental
protection of lighting,
solenoid, motor, and
transformer circuits
® CSA Certified to
Standard C22.2 No. 248.14
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
1/10
1/8
15/100
3/16
2/10
1/4
CATALOG AMPERE CATALOG
NUMBER RATING NUMBER
ATQ1/10
3/10
ATQ3/10
ATQ1/8
4/10
ATQ4/10
ATQ15/100
1/2
ATQ1/2
ATQ3/16
6/10
ATQ6/10
ATQ2/10
8/10
ATQ8/10
ATQ1/4
1
ATQ1
AMPERE CATALOG AMPERE CATALOG
RATING NUMBER RATING NUMBER
1-1/8
ATQ1-1/8
2
ATQ2
1-1/4
ATQ1-1/4
2-1/8
ATQ2-1/8
1-4/10 ATQ1-4/10 2-1/4
ATQ2-1/4
1-1/2
ATQ1-1/2
2-1/2
ATQ2-1/2
1-6/10 ATQ1-6/10 2-8/10 ATQ2-8/10
1-8/10 ATQ1-8/10
3
ATQ3
AMPERE
RATING
3-2/10
3-1/2
4
4-1/2
5
5-6/10
CATALOG AMPERE CATALOG AMPERE
NUMBER RATING NUMBER RATING
ATQ3-2/10
6
ATQ6
12
ATQ3-1/2
6-1/4 ATQ6-1/4
14
ATQ4
7
ATQ7
15
ATQ4-1/2
8
ATQ8
20
ATQ5
9
ATQ9
25
ATQ5-6/10
10
ATQ10
30
CATALOG
NUMBER
ATQ12
ATQ14
ATQ15
ATQ20
ATQ25
ATQ30
Melting Time — Current Data 4 - 30 Amperes, 500 Volts AC
Time in Seconds
Time in Seconds
Melting Time — Current Data 1/10 - 3-1/2 Amperes, 500 Volts AC
Current in Amperes
Current in Amperes
C2
AMP-TRAP®
ATMR
CLASS CC
SMALL FUSE - BIG PROTECTION
FOR GENERAL CIRCUITS
Amp-trap ATMR fuses, in the Class CC family,
are the smallest dimension 600V fuses suitable for
branch circuit protection. The ATMR is a popular choice
for economical protection of control circuits and
control circuit transformers where available short circuit
currents exceed 10,000 amperes. ATMR’s rejection
dimensions prevent substitution by lesser rated fuses.
These fast acting fuses give current limiting protection
to general circuits.
Features / Benefits
® Rejection style design prevents replacement errors
when used with recommended fuse blocks
® Fiberglass body provides dimensional stability in
harsh industrial environments
® Versatile design for individual component and
branch circuit protection
HIGHLIGHTS:
APPLICATIONS:
®
®
Fast Acting
® Very Current-Limiting
Ratings
® AC: 1/10 to 30A
600VAC, 200kA I.R.
Control Circuits
® Lighting
® General Loads
® Branch Circuit
Protection
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1/10
1/8
ATMR1/10
ATMR1/8
3-1/2
4
ATMR3-1/2
ATMR4
2/10
1/4
ATMR2/10
ATMR1/4
5
6
ATMR5
ATMR6
3/10
1/2
3/4
ATMR3/10
ATMR1/2
ATMR3/4
7
8
9
ATMR7
ATMR8
ATMR9
1
1-1/4
ATMR1
ATMR1-1/4
10
12
ATMR10
ATMR12
1-1/2
2
2-1/2
ATMR-1-1/2
ATMR2
ATMR2-1/2
15
20
25
ATMR15
ATMR20
ATMR25
3
ATMR3
30
ATMR30
® UL Listed to
Standard 248-4
® CSA Certified to
Standard C22.2
No. 248.4
Standard Fuse Ampere Ratings,
Catalog Numbers
AMPERE
RATING
Approvals
B 28
AMP-TRAP®
FAST ACTING / CLASS CC FUSES
ATMR
Recommended Fuse Blocks For Amp-Trap® Class CC Fuses
Dimensions
CATALOG NUMBER
Number of
Poles
ULTRASA F E “
Indicating
Fuse Holders
Screw Connector
with Double
Quick Connects
Pressure Plate
Connector
with Double
Quick Connects
ADDER
1
2
3
USCC1I
USCC2I
USCC3I
30310R
30311R
30312R
30313R
30320R
30321R
30322R
30323R
Refer to the Class CC Fuse Block section of this catalog for other details.
Current in Amperes
Melting Time — Current Data, 600V Fuses
ATMR1/10 to 30
Maximum Instantaneous Peak Let-Thru Amperes
Time in Seconds
Peak Let-Thru Current Data — ATMR3/4 to 30, 600 Volts AC
Current in Amperes
B 29
Copper Box
Connector
30350R
30351R
30352R
30353R
B
AMP-TRAP®
ATM
1-1/2" X 13/32"
Amp-trap midget fast-acting ATM fuses are rated
600 volts AC, with a 100kA interrupting rating.
These ratings give the ATM a wide range of
applications not covered by other midget fuses.
In addition, ratings of 30/35, 30/40 and 30/50
amperes are offered for specific applications such
as capacitor protection. These ATM fuses must
still be considered 30A fuses because of their
dimensions, but are able to withstand much
higher inrush currents and tougher duty cycles.
(Not for Branch Circuit Protection).
HIGHLIGHTS:
APPLICATIONS:
®
Fast Acting
®
®
Special Ratings
(above 30A)
Supplemental protection
of a wide variety of
circuits up to 600VAC
and 500VDC with
100kA I.R.
MIDGET FUSES
Features / Benefits
® For supplemental protection of small
motors and transformers
® Extended ratings for special protection of
capacitors and circuits with high inrush currents
® 500VDC ratings for a wide variety of
applications
® Can be used with ULTRASAFE™ fuse holders
Ratings
Approvals
® AC: 1/10 to 30A
600VAC, 100kA I.R.;
35 to 50A
600VAC, 10kA I.R.
® UL Listed to
Standard 248-14
(1/10 to 30A)
® DC: 1/10 to 30A
500VDC, 100kA I.R.
® DC listed to UL
Standard 248-14
(1/10 to 30A)
® CSA Certified to
Standard C22.2 No. 248.14
(1/10 to 30A)
Melting Time — Current Data 1/10 - 30/50 Amperes, 600 Volts AC
Time in Seconds
Standard Fuse Ampere Ratings,
Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1/10
1/8
2/10
1/4
1/2
3/4
1
1-1/2
2
3
4
5
ATM1/10
ATM1/8
ATM2/10
ATM1/4
ATM1/2
ATM3/4
ATM1
ATM1-1/2
ATM2
ATM3
ATM4
ATM5
6
8
10
12
15
20
25
30
30/35
30/40
30/50
ATM6
ATM8
ATM10
ATM12
ATM15
ATM20
ATM25
ATM30
ATM30/35*
ATM30/40*
ATM30/50*
* are not continuous current rated devises
Current in Amperes
C4
Download