AMP-TRAP 2000® ATDR TIME DELAY / CLASS CC THE BEST PROTECTION FOR TODAY’S SMALL MOTORS. Amp-trap 2000® ATDR small-dimension fuses can provide IEC Type 2 “no damage” protection to your facility’s increasingly sensitive branch circuit components and small motors – minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time delay characteristics in their class with excellent cycling ability for small motor loads. Features/Benefits Time delay for motor starting inrush currents without nuisance opening Highly current limiting for low peak let-thru current Improved cycling ability for frequent motor starts/stops without nuisance fuse opening Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label ensures instant recognition, simplifies replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and optimum current limitation HIGHLIGHTS: APPLICATIONS: Time Delay Best Choice for Small Motor Protection Highly Current-Limiting AC & DC Rated Small Motors Contactors Lighting, Heating & General Loads Branch Circuit Protector Ratings A C : 1/4 to 30A 600VAC, 200kA I.R. D C : 1/4 to 30A 300VDC, 100kA I.R. A 13 Approvals UL Listed to Standard 248-4 CSA Certified to Standard C22.2 No. 248.4 DC Listed to UL Standard 198L A AMP-TRAP 2000® TIME DELAY / CLASS CC FUSES ATDR Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1/4 1/2 8/10 1 1-1/8 1-1/4 1-4/10 ATDR1/4 ATDR1/2 ATDR8/10 ATDR1 ATDR1-1/8 ATDR1-1/4 ATDR1-4/10 1-1/2 1-6/10 1-8/10 2 2-1/4 2-1/2 2-8/10 ATDR1-1/2 ATDR1-6/10 ATDR1-8/10 ATDR2 ATDR2-1/4 ATDR2-1/2 ATDR2-8/10 3 3-2/10 3-1/2 4 4-1/2 5 5-6/10 ATDR3 ATDR3-2/10 ATDR3-1/2 ATDR4 ATDR4-1/2 ATDR5 ATDR5-6/10 6 6-1/4 7 7-1/2 8 9 10 ATDR6 ATDR6-1/4 ATDR7 ATDR7-1/2 ATDR8 ATDR9 ATDR10 12 15 17-1/2 20 25 30 ATDR12 ATDR15 ATDR17-1/2 ATDR20 ATDR25 ATDR30 Dimensions Small Motor Fuse Protection, 600 Volts AC or Less MOTOR FULL LOAD AMPERES .71 - .89 .90 - 1.19 1.20 - 1.34 1.35 - 1.79 1.80 - 2.25 2.26 - 2.69 2.70 - 2.90 2.91 - 3.20 3.21 - 3.75 3.76 - 4.50 4.51 - 5.34 5.35 - 5.69 5.70 - 6.70 6.71 - 7.79 7.80 - 8.88 8.89 - 11.1 11.2 - 13.3 13.4 - 15.2 ATDR RATING* MINIMUM NORMAL DUTY DUTY 1-1/4 1-6/10 2 2-1/2 3 4 4 5 5 6 8 10 12 12 15 17-1/2 20 25 Recommended Fuse Blocks for Class CC Fuses 1-6/10 2 2-1/2 3 4 5 6 6 7 8 10 12 12 15 17-1/2 20 25 30 CATALOG NUMBER Screw ULTRASA F E “ Connector Number Indicating w/ Double of Fuse Quick Poles Holder Connects ADDER 1 2 3 * The National Electrical Code allows time-delay Class CC fuses to be sized at up to 400% (maximum) of motor FLA, if needed. A 14 USCC1I USCC2I USCC3I 30310R 30311R 30312R 30313R Pressure Plate Connector Copper w/ Double Box Quick Connects Connector 30320R 30321R 30322R 30323R 30350R 30351R 30352R 30353R AMP-TRAP 2000® TIME DELAY / CLASS CC FUSES ATDR ATDR1/4 to 30 Current in Amperes Melting Time — Current Data, 600V Fuses A Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data — ATDR1/4 to 30, 600 Volts AC Available Current in RMS Symmetrical Amperes A 15 USCC & USM TM 24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS ULTRASAFE MODULAR FUSE HOLDERS Ferraz Shawmut ULTRASAFETM modular 24, 48 and 600 volt Fuse Holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2" x 13/32" (USM) as well as DC rated fuses up to 30 amperes. ULTRASAFE holders qualify as “finger safe” under IEC and DIN standards to an IP20 grade of protection, including fuse changing (with the flick of a finger). ULTRASAFE holders are available in 1, 2, 3 or 4 poles, with or without blown-fuse indicators in each pole. AC indicators are orange and DC are red. The multi-pole units can also be made up by ordering pin-tie handles for field assembly. ULTRASAFE holders save up to 15% mounting space and any combination can be snapped onto 35mm DIN rail for extra savings in panel building time. ULTRASAFE holders with Class CC fuses chosen for Type “2” protection give one of the safest protection packages in the industry. Ultrasafe body material is tough and durable polyamide, with exceptional insulating properties. Ratings HIGHLIGHTS: APPLICATIONS: All circuits up to Finger Safe 600 volts for motors, Optional Indicator Lights control circuits, DIN Rail Mount transformers, etc. Compact Footprint Non-load disconnect Quick, Easy Fuse Change 12, 24 and 48 volt DC circuits 600VAC, 30A Min. voltage to operate indicator light: 90VAC [Less than 0.7 mA leakage current at 600V] Special Indicator for 24VDC, 30A Special Indicator for 48VDC, 30A Withstand rating: Class CC 200kA I.R. Midget Fuse 100kA I.R. RECOMMENDED FUSE USAGE USCC . . . . . . . . . . . . . . .use with ATDR*, ATMR, ATQR USM . . . . . . . . . . . . . . . .use with ATQ, ATM*, A6Y-2B, A25Z-2, TRM, OTM, A13X-2, GFN, GGU, A60Q-2 * Recommended for DC Applications H2 Approvals All Ultrasafe Fuse Holders meet the requirements of UL512 UL Listed Class CC Guide IZLT, File E52283 UL Recognized Component Midget Guide IZLT2, File E52283 CSA Certified Class CC & Midget C22.2, Class 6225 File 32169 IEC 269 690VAC, 32A Midget version only. USCC & USM TM 24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS For use with Class CC Fuses CATALOG NO. DESCRIPTION USCC1 USCC1I USCC2 USCC2I USCC3 USCC3I USCC3IN USCC3N USCC4 USCC4I 1 pole 1 pole with indicator 2 pole 2 pole with indicators 3 pole 3 pole with indicators 3 pole with indicators and a 4th neutral pole 3 pole with a 4th neutral pole 4 pole 4 pole with indicators For use with Midget (1-1/2” x 13/32”) Fuses USM1 USM1I USM2 USM2I USM3 USM3I USM3IN USM3N USM4 USM4I 1 pole 1 pole with indicator 2 pole 2 pole with indicators 3 pole 3 pole with indicators 3 pole with indicators and a 4th neutral pole 3 pole with a 4th neutral pole 4 pole 4 pole with indicators Neutral Link Pole USN 1 Pole with Integral Neutral Link Accessories USPTH2 USPTH3 USPTH4 Pin-tie handle for 2 poles Pin-tie handle for 3 poles Pin-tie handle for 4 poles Special Indicator Options For use with Low Voltage DC Rated Class CC & Midget Fuses PART NUMBER INDICATOR TYPE OPERATING LEAKAGE VOLTAGE CURRENT USM1I-DC24 USM1I-DC24P USM1I-DC48 USCC1I-DC24 USCC1I-DC48 LED LED LED LED LED 12 to 24 VDC 20 to 24 VDC 35 to 48 VDC 12 to 24 VDC 35 to 48 VDC 10mA max.(@24vdc) 1mA max.(@24vdc) 10mA max.(@48vdc) 10mA max.(@24vdc) 10mA max.(@48vdc) Dimensions DIMENSION mm In A B C D 17.5 35.0 52.5 70.0 0.69 1.38 2.07 2.76 E F G H 78.0 2.5 78.0 59.0 3.07 0.10 3.07 2.32 I J K 42.5 5.0 45.0 1.67 0.20 1.77 Terminal screws: Phillips/slot head Suggested screw torque: 14.75 in-lbs. Connector type: Pressure plate Wire range: #6 to #14 (solid/stranded Cu) Load-break disconnect: No H3 H TRI-ONIC® TRM 1-1/2" X 13/32" Tri-onic TRM time-delay midget fuses are rated 250 volts AC and are offered in 36 ampere ratings from 1/10A to 30A. They have 12 seconds time delay at 200% rating to provide supplemental protection of small motors, small transformers and other high inrush loads, plus many other 250 volt applications. (Not for Branch Circuit Protection). HIGHLIGHTS: APPLICATIONS: ® Time Delay ® 250 VAC Rated ® ® ® ® MIDGET FUSES Features / Benefits ® Numerous ratings for a wide variety of applications ® 250VAC rating in all sizes up to 30A ® Time delay for circuits with high inrush currrent ® Can be used with ULTRASAFE™ fuse holders C Approvals Ratings ® AC: 1/10 to 30A 250VAC, 10kA I.R. Small Motors Small Transformers Lighting Circuits Control Circuits ® UL Listed to Standard 248-14 ® CSA Certified to Standard C22.2 No. 248.14 Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING 1/10 15/100 2/10 3/10 4/10 1/2 CATALOG NUMBER TRM1/10 TRM15/100 TRM2/10 TRM3/10 TRM4/10 TRM1/2 AMPERE RATING 6/10 8/10 1 1-1/8 1-1/4 1-4/10 CATALOG NUMBER TRM6/10 TRM8/10 TRM1 TRM1-1/8 TRM1-1/4 TRM1-4/10 AMPERE RATING 1-6/10 1-8/10 2 2-1/4 2-1/2 2-8/10 CATALOG NUMBER TRM1-6/10 TRM1-8/10 TRM2 TRM2-1/4 TRM2-1/2 TRM2-8/10 AMPERE RATING 3 3-2/10 3-1/2 4 4-1/2 5 Melting Time — Current Data 1/10 - 3-1/2 Amperes, 250 Volts AC CATALOG NUMBER TRM3 TRM3-2/10 TRM3-1/2 TRM4 TRM4-1/2 TRM5 AMPERE RATING 5-6/10 6 6-1/4 7 8 9 CATALOG NUMBER TRM5-6/10 TRM6 TRM6-1/4 TRM7 TRM8 TRM9 AMPERE RATING 10 12 15 20 25 30 CATALOG NUMBER TRM10 TRM12 TRM15 TRM20 TRM25 TRM30 Time in Seconds Time in Seconds Melting Time — Current Data 4 - 30 Amperes, 250 Volts AC Current in Amperes Current in Amperes C5 ONE TIME OTM 1-1/2" X 13/32" One-time OTM midget fuses provide lowcost protection for 250 volt AC general purpose lighting, heating, control circuits, etc. where time delay is not required. (Not for Branch Circuit Protection). HIGHLIGHTS: APPLICATIONS: ® Fast Acting ® ® 250VAC Rated MIDGET FUSES Features / Benefits ® Low cost and fully rated for economy without compromise ® Can be used with ULTRASAFE™ fuse holders Approvals Ratings Supplemental protection of circuits up to 250VAC and 10kA ® AC: 1 to 30A 250VAC, 10kA I.R. ® UL Listed to Standard 248-14 ® CSA Certified to Standard C22.2 No. 248.14 Melting Time — Current Data 1-30 Amperes, 250 Volts AC Standard Fuse Ampere Ratings, Catalog Numbers Time in Seconds AMPERE RATING 1 2 3 4 5 6 8 10 15 20 25 30 Current in Amperes C6 CATALOG NUMBER OTM1 OTM2 OTM3 OTM4 OTM5 OTM6 OTM8 OTM10 OTM15 OTM20 OTM25 OTM30 MIDGET & CLASS CC 600 VOLT / FUSE BLOCKS 600 VOLT MIDGET AND CLASS CC FUSE BLOCKS Ferraz Shawmut Midget Fuse Blocks accommodate all 30 ampere 1-1/2" x 13/32" midget fuses. Class CC Fuse Blocks accommodate all 30 ampere Class CC fuses. A choice of box, screw, or pressure-plate connectors fit a wide range of stranded or solid copper wire. Insulators are glass-filled polycarbonate (GFPC) with verified dielectric strength in excess of 2500V. Fuse blocks feature a unique adder block which can be snapped onto 1-, 2- or 3-pole blocks to form multi-pole segmented blocks of as many poles as desired. All fuse clips are made of high conductivity tin-plated copper alloy. Ratings Approvals ® 600VAC: 30A ® Withstand rating: 200kA using screw, pressure plate or box connections, 10kA using quick connects RECOMMENDED FUSE USAGE Midget Fuse Block . . . . .use with ATQ, ATM, A6Y-2B, A25Z-2, TRM, OTM, A13X-2, GFN, GGU, A60Q-2 ® Temperature/ flammability: GFPC insulators rated 125˚C, 94V-0 flammability Class CC Fuse Block . . . .use with ATDR, ATMR, ATQR ® All fuse blocks meet the requirements of UL Std. 512 Midget Block ® UL Recognized Component Guide IZLT2, File E52283 ® CSA Certified Class 6225, File 32169 Class CC Block ® UL Listed, Guide IZLT, File E52283 ® CSA Certified Class 6225, File 32169 Clip & Connector Types 30A MIDGET/CC COPPER BOX CONNECTOR SCREW WITH DOUBLE QUICKCONNECTS PRESSURE PLATE WITH DOUBLE QUICKCONNECTS H 13 PRESSURE PLATE WITH DOUBLE QUICKCONNECTS (CLASS CC REJECTION END) H MIDGET & CLASS CC Adder 1 Pole 2 Pole 600 VOLT / FUSE BLOCKS 3 Pole Recommended mounting screws for all Midget and Class CC fuse blocks: #8 (.164" dia.) 600 Volt, 30A Midget and Class CC Fuse Blocks CONNECTOR TYPE WIRE RANGE Screw w/double quick connects at both ends Cu #10-14 Pressure plate (sems) w/double quick connects at both ends Cu #10-14 Copper box Cu #6-14 POLES* MIDGET ADDER 1 2 3 4 30310 30311 30312 30313 30314 ADDER 1 2 3 4 30320 30321 30322 30323 30324 ADDER 1 2 3 4 30350 30351 30352 30353 30354 CATALOG NUMBER TYPE OF FUSE LISTING CLASS CC ® & CSA ® & CSA ® & CSA LISTING CONNECTOR TORQUE In - lb 30310R 30311R 30312R 30313R 30314R UL & CSA 20 30320R 30321R 30322R 30323R 30324R UL & CSA 20 30350R 30351R 30352R 30353R 30354R UL & CSA 35 Note: To convert Midget or Class CC adder pole to single pole, use end barrier #U09301. * Available in any number of poles. Replace last digit in Catalog Number with number of poles needed. Example: 303112 is a 12-pole screw/double QC connector Midget Fuse Block. Total width of N poles = (N x .76) + .08 inches. 12 poles = (12 x .76") + .08" = 9.20". Note: Please see fuse block accessories (H 63) for information regarding fuse block accessories; DFC3M, DFC3LP or DRM. H 14 GPM SERIES PANEL MOUNT / FUSE HOLDERS GPM PANEL MOUNT FUSE HOLDERS Ferraz Shawmut GPM Panel Mount Fuse Holders are in sizes to accommodate 5mm x 20mm, 1/4" x 1-1/4", Class CC and Midget (1-1/2" x 13/32") fuses. All 30A holders have glass-filled polyester insulators for extra dependability and trouble-free installation. Patented design allows same body to accept screw or bayonet knob. Flange design allows front or rear mounting. The 10A and 15A holders are for front mounting only. Approvals ® GPM-A, GPM-G: UL Recognized, Guide IZLT2, File E118864 CSA Certified, Class 908501, File AP82191 ® All others: UL Recognized, Guide IZLT2, File E52283 CSA Certified, Class 6225, File 32169 RECOMMENDED FUSE USAGE GPM Fuse Holders will accommodate these Ferraz Shawmut fuses: GPM-A: GGM, GGA, GSC GPM-G: GSA, GDL, GGC, GSB, GDG, GAB GPM-SRR, GPM-BRR, GPM-WTR: ATQR, ATDR, ATMR GPM-SRR90, GPM-BRR90, GPM-WTR90: ATQR, ATDR, ATMR ATQ, ATM, TRM, OTM, GGU, GPM-S, GPM-B, GPM-WT: GPM-S90, GPM-B90, GPM-WT90: A13X-2, A25Z-2, A60Q-2, A6Y-2B H } Figure 1 Figure 2 Catalog Numbers & Descriptions Figure 3 CATALOG NO. FIG. CAP TYPE AMPS VOLTS FUSE TYPE GPM-A GPM-G GPM-S GPM-S90 GPM-SRR GPM-SRR90 1 2 3 4 3 4 Screw Knob Screw Knob Screw Knob Screw Knob Screw Knob Screw Knob 10 15 30 30 30 30 250 250 600 600 600 600 5mm x 20mm 1/4" x 1-1/4" 1-1/2" x 13/32" 1-1/2" x 13/32" Class CC Class CC TERMINAL TYPE Solder Solder 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle GPM-B GPM-B90 GPM-BRR GPM-BRR90 3 4 3 4 1/4 Turn Bayonet Knob 1/4 Turn Bayonet Knob 1/4 Turn Bayonet Knob 1/4 Turn Bayonet Knob 30 30 30 30 600 600 600 600 1-1/2" x 13/32" 1-1/2" x 13/32" Class CC Class CC 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle GPM-WT GPM-WT90 GPM-WTR GPM-WTR90 3 4 3 4 Water-tight Screw Knob Water-tight Screw Knob Water-tight Screw Knob Water-tight Screw Knob 30 30 30 30 600 600 600 600 1-1/2" x 13/32" 1-1/2" x 13/32" Class CC Class CC 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle 1/4" Quick-connect/Solder 1/4" Quick-connect/Solder, Right Angle H 19 Figure 4 GPM-SERIES PANEL MOUNT / FUSE HOLDERS GPM-SERIES RF Shielded/watertight panel mount for 3AG fuses. Radio frequency shielded fuseholders eliminate possible transmission or reception of RF signals through the hole in the chassis in which the fuseholder is mounted. These fuseholders comply with the watertight construction requirement of MIL-F-19207 and the Shock-Safe requirements of IEC 65 and 257. A rubber O-ring and conductive gasket maintain RF shielding and watertight construction. Catalog Numbers & Descriptions CATALOG NO. BRASS SHIELDING. CAP FINISH GPM-RFN GPM-RFB NICKEL PLATED DULL BLACK H 20 GPM SERIES PANEL MOUNT / FUSE HOLDERS INTERNATIONAL SHOCK-SAFE PANEL MOUNT TYPE FUSES A complete selection of styles satisfy a wide variety of fuseholder design needs. Designed to eliminate the possibility of electrical shock, as defined in IEC standards 65 and 127. The Universal fuseholder body will accept 3AG, 5x20mm, and 2AG fuse sizes depending on knob selected. Permits inventory reduction of bodies and provides knob interchange versatility. Anti-tease feature eliminates circuit interruption when knob is accidentally depressed. Five fuseholder types assure design flexibility. Available with two knob styles – screwdriver slot or fingertip. Available in two terminal styles – dual purpose for soldering or 3/16" NEMA quick connect; and 1/4" NEMA/DIN quick connect. Quick fuse size identification is provided with color-coded letters on fingergrip knob and color-coded screwdriver slot knobs. Specifications Electrical: Insulation Resistance: 10,000 Megohm minimum at 500 VDC. Contact Resistance: Less than .005 ohms average at currents up to 1 ampere. Mounting: Threaded styles withstand 15 in.-lb. mounting torque. Low profile and High profile panel thickness: .032" min./.310" max. Quick mount panel thickness: .012" min./.360" max. Rear mount panel thickness: .012" min./.260" max. Molded Parts: Body material: Black glass-filled thermoplastic (UL 94VO) Knob material: Grey, blue or black glass-filled thermoplastic (UL 94V0). Hex Nut Material: Black glass-filled thermoplastic. Knob: Finger-Grip, Fuse Extractor type or Screwdriver Slot, Fuse Extractor type with plated copper alloy contact clips. Spring loaded, locking mechanism provides anti-tease feature and will not vibrate loose. Terminals: Copper alloy. Tin-plated. Three styles available. A .187" dual purpose terminal accepts wire for soldering or a Quick-Connect receptacle. .187" terminal for NEMA Quick-Connect and .250" terminal for NEMA/DIN Quick-Connect available. Ambient Temperature: -40ºC to +85ºC. Hardware: Threaded style fuseholders are supplied with thermoplastic hex nut unassembled. Quick Mount style fuseholders are supplied with a push-on type retaining nut, black oxide finish, unassembled. H 21 APPROVALS CSA SEMKO VDE 3AG 20A 250V 20A 250V 6.3A 250V 10A 250V 5x20mm 10A 250V 10A 250V 10A 250V 10A 250V 2AG 10A 250V 10A 250V - H GPM SERIES PANEL MOUNT / FUSE HOLDERS Ordering Information: Cap Suffix: -020 / Example: Body Suffix: -010 GPM - A LS 7 Fuse Size Style Terminals M 2AG-.177" x .570" LF Low Profile Body, Black Fingergrip Knob 1 3/16" (Rt. Angle) Dual Purpose Solder/QC G 3AG-.250" x 1.250" RF Rear Mount Body, Black Fingergrip Knob Fingergrip Knob: 2AG-Blue Letters 3AG-White Letters 5x20mm-Red Letters 2 3/16" (Straight) Dual Purpose Solder/QC HS High Profile Body Screwdriver Slot Knob 4 3/16" (Straight) NEMA/QC LS Low Profile Body Screwdriver Slot Knob 7 1/4" (Rt. Angle) NEMA/DIN QC QS Quick Mount Body Screwdriver Slot Knob Screwdriver Slot Knob: 2AG-Blue Knob 3AG-Grey Knob 5x20mm-Black Knob 8 1/4" (Straight) NEMA/DIN QC A 5 x 20mm-.197" x 787" 3 3/16" (Rt. Angle) NEMA/QC To Order Knob Only: FUSE SIZE FINGERGRIP KNOB PART NUMBER SCREWDRIVER SLOT KNOB PART NUMBER 2AG 3AG 5x20mm GPM-MLF1-020 GPM-GLF1-020 GPM-ALF1-020 GPM-MLS1-020 GPM-GLS1-020 GPM-ALS1-020 To Order Body Including Nut(s) Only: TERMINAL STYLE BOTTOM TERMINAL LOW PROFILE BODY HIGH PROFILE BODY REAR MOUNT BODY QUICK MOUNT BODY Part Number*** Part Number Part Number Part Number 3/16" Dual Purpose 3/16" Dual Purpose 3/16" NEMA QC 3/16" NEMA QC 1/4" NEMA/DIN QC 1/4" NEMA/DIN QC (Rt. Angle) (Straight) (Rt. Angle) (Straight) (Rt. Angle) (Straight) GPM-ALF1-010 GPM-ALF2-010 GPM-ALF3-010 GPM-ALF4-010 GPM-ALF7-010 GPM-ALF8-010 GPM-AHS1-010 GPM-AHS2-010 GPM-AHS3-010 GPM-AHS4-010 GPM-AHS7-010 GPM-AHS8-010 GPM-ARF1-010 GPM-ARF2-010 GPM-ARF3-010 GPM-ARF4-010 GPM-ARF7-010 GPM-ARF8-010 GPM-AQS1-010 GPM-AQS2-010 GPM-AQS3-010 GPM-AQS4-010 GPM-AQS7-010 GPM-AQS8-010 *** Low profile body will accept either Fingergrip or Screwdriver Slot Knob. Note: Consult factory for ordering combined packages with knob and body. H 22 DFC3M/DFC3LP/DRM FUSE BLOCK ACCESSORIES DFC3M SAFETY PULLER PROTECTS PERSONNEL, COVERS LIVE PARTS The DFC3M Safety Puller is intended to hold and safely enclose 1-1/2" x 13/32" Midget or Class CC fuses for insertion or removal from fuse clips, making fuse installation easy and safe without the use of a standard fuse puller. The DFC3M is made of clear polycarbonate, so the fuse can be identified when installed in a 303 series fuse block. DFC3LP SAFETY PULLER HOLDS FUSE, PROTECTS PERSONNEL AND SAVES SPACE The DFC3LP holds and safely encloses 1-1/2" x 13/32" Midget or Class CC fuse, similar to the DFC3M, but with a lower profile in height so it takes less room where space is restricted. The DFC3LP is made of clear polycarbonate so the fuse can be seen after installation in a fuse block such as the Ferraz Shawmut 303 series. DRM ADAPTS 303 SERIES MIDGET AND CLASS CC FUSE BLOCKS TO DIN RAIL The DIN rail adapter, DRM, provides quick mounting for all Ferraz Shawmut 303 Series Midget and Class CC fuse blocks to all symmetrical 35mm DIN or asymmetrical 32mm “G” rail. A DRM adapter is attached to each pole with the screw provided. The DRM is molded of black polycarbonate and is mounted or dismounted from the rail simply by depressing the finger pull. H 62 AMP-TRAP 2000® ATQR TIME DELAY / CLASS CC TAKE CONTROL OF FAULT CURRENTS HEADED FOR YOUR CONTROL TRANSFORMER ATQR small-dimension fuses feature time delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. The newest member of our Amp-trap 2000® family of fuses - ATQR fuses provide superior protection for the branch circuits of electrical distribution systems. Features/Benefits ® Time delay for control transformer inrush loads without nuisance opening ® Highly current limiting for low peak let-thru current ® Rejection-style design prevents replacement errors (when used with recommended fuse blocks) ® High-visibility orange label ensures instant recognition, and simplifies replacement ® Metal-embossed date and catalog number for traceability and lasting identification ® Fiberglass body provides dimensional stability in harsh industrial settings ® High-grade silica filler ensures fast arc quenching and high current limitation HIGHLIGHTS: APPLICATIONS: ® ® Time Delay ® Best Choice for Small Transformer Protection ® Most Current-Limiting Ratings Control Transformers ® Solenoids ® Inductive Loads ® Lighting, Heating & General-purpose Loads A 16 ® AC: 1/10 to 30A 600VAC, 200kA I.R. Approvals ® UL Listed to Standard 248-4 ® CSA Certified to Standard C22.2 No. 248.4 AMP-TRAP 2000® TIME DELAY / CLASS CC FUSES ATQR Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1/10 1/8 15/100 3/16 2/10 1/4 3/10 4/10 1/2 6/10 3/4 ATQR1/10 ATQR1/8 ATQR15/100 ATQR3/16 ATQR2/10 ATQR1/4 ATQR3/10 ATQR4/10 ATQR1/2 ATQR6/10 ATQR3/4 8/10 1 1-1/8 1-1/4 1-4/10 1-1/2 1-6/10 1-8/10 2 2-1/4 2-1/2 ATQR8/10 ATQR1 ATQR1-1/8 ATQR1-1/4 ATQR1-4/10 ATQR1-1/2 ATQR1-6/10 ATQR1-8/10 ATQR2 ATQR2-1/4 ATQR2-1/2 2-8/10 3 3-2/10 3-1/2 4 4-1/2 5 5-6/10 6 6-1/4 7 ATQR2-8/10 ATQR3 ATQR3-2/10 ATQR3-1/2 ATQR4 ATQR4-1/2 ATQR5 ATQR5-6/10 ATQR6 ATQR6-1/4 ATQR7 7-1/2 8 9 10 12 15 17-1/2 20 25 30 ATQR7-1/2 ATQR8 ATQR9 ATQR10 ATQR12 ATQR15 ATQR17-1/2 ATQR20 ATQR25 ATQR30 Recommended ATQR Class CC Primary Fuses For Single Phase Control Transformers TRANS VA 25 50 75 100 150 200 250 PRIMARY VOLTS FLA 600 0.04 480 0.05 240 0.10 208 0.12 120 0.21 600 0.08 480 0.10 240 0.21 208 0.24 120 0.42 600 0.13 480 0.16 240 0.31 208 0.36 120 0.63 600 0.17 480 0.21 240 0.42 208 0.48 120 0.83 600 0.25 480 0.31 240 0.63 208 0.72 120 1.25 600 0.33 480 0.42 240 0.83 208 0.96 120 1.67 600 0.42 480 0.52 240 1.04 208 1.2 120 2.08 ATQR AMPS 1/10 1/10 2/10 1/4 4/10 1/4 1/4 4/10 1/2 6/10 1/4 3/10 1/2 3/4 1 3/10 4/10 6/10 1 1-1/2 1/2 1/2 1 1-1/2 2-1/2 1/2 6/10 1-1/2 2 3 6/10 1-1/8 2 3 4* TRANS VA 300 500 750 1000 1500 2000 3000 5000 PRIMARY VOLTS FLA 600 0.50 480 0.63 240 1.25 208 1.44 120 2.5 600 0.83 480 1.04 240 2.08 208 2.40 120 4.17 600 1.25 480 1.56 240 3.13 208 3.61 120 6.25 600 1.67 480 2.08 240 4.16 208 4.81 120 8.33 600 2.50 480 3.13 240 6.25 208 7.21 120 12.5 600 3.33 480 4.17 240 8.33 208 9.62 600 5.00 480 6.25 240 12.5 600 8.33 480 10.4 ATQR AMPS 1-1/8 1-1/2 2-1/2 3 5* 1-1/2 2 4* 6* 10* 2-1/2 3 7* 8* 15* 3 4* 10* 12* 20* 5* 7* 10 20* 25* 8* 10* 20++* 20++* 12+* 15+* 30++* 20++* 25+* A Dimensions Recommended Fuse Blocks for Class CC Fuses Number of Poles ADDER 1 2 3 Screw ULTRASA F E “ Indicating with Double Quick Fuse Connects Holder USCC1I USCC2I USCC3I Pressure Plate with Double Quick Connects Copper Box Connector 30320R 30321R 30322R 30323R 30350R 30351R 30352R 30353R 30310R 30311R 30312R 30313R Primary fuses - If primary FLA is less than 2 amps, fuse may be 300% max. (500% for motor control). If primary FLA exceeds 2 amps but is less than 9 amps, fuse may not exceed 167% of primary FLA unless secondary protection is used, when it may be increased to 250%. Fuse sizes shown are based on approx. 40 x FLA for .01 sec. * Secondary protection is required for these ratings. + Fuse will withstand 30 x FLA for .01 second ++ Fuse will withstand 25 x FLA for .01 second A 17 AMP-TRAP 2000® TIME DELAY / CLASS CC FUSES ATQR Current in Amperes Melting Time — Current Data, 600V Fuses ATQR1/8 to 30 Time in Seconds Max. Instantaneous Peak Let-Thru Current Peak Let-Thru Current Data — ATQR1/8 to 30, 600 Volts AC Available Current in RMS Sym. Amperes A 18 AMP-TRAP® ATQ 1-1/2" X 13/32" Amp-trap ATQ midget time-delay fuses are rated a full 500 volts AC with 42 ampere ratings from 1/10 to 30A. They are an excellent choice for supplemental protection of circuits up to 30A where the available short circuit current does not exceed 10,000A. (Not for Branch Circuit Protection). MIDGET FUSES Features / Benefits ® Numerous ratings for a wide variety of applications up to 500VAC ® Time Delay (12 seconds at 200% rating) for circuits with high inrush current ® Can be used with ULTRASAFE™ Fuseholders HIGHLIGHTS: APPLICATIONS: Ratings Approvals ® ® ® AC: 1/10 to 30A 500VAC, 10kA I.R. ® UL Listed to Standard 248-14 Time Delay Supplemental protection of lighting, solenoid, motor, and transformer circuits ® CSA Certified to Standard C22.2 No. 248.14 Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING 1/10 1/8 15/100 3/16 2/10 1/4 CATALOG AMPERE CATALOG NUMBER RATING NUMBER ATQ1/10 3/10 ATQ3/10 ATQ1/8 4/10 ATQ4/10 ATQ15/100 1/2 ATQ1/2 ATQ3/16 6/10 ATQ6/10 ATQ2/10 8/10 ATQ8/10 ATQ1/4 1 ATQ1 AMPERE CATALOG AMPERE CATALOG RATING NUMBER RATING NUMBER 1-1/8 ATQ1-1/8 2 ATQ2 1-1/4 ATQ1-1/4 2-1/8 ATQ2-1/8 1-4/10 ATQ1-4/10 2-1/4 ATQ2-1/4 1-1/2 ATQ1-1/2 2-1/2 ATQ2-1/2 1-6/10 ATQ1-6/10 2-8/10 ATQ2-8/10 1-8/10 ATQ1-8/10 3 ATQ3 AMPERE RATING 3-2/10 3-1/2 4 4-1/2 5 5-6/10 CATALOG AMPERE CATALOG AMPERE NUMBER RATING NUMBER RATING ATQ3-2/10 6 ATQ6 12 ATQ3-1/2 6-1/4 ATQ6-1/4 14 ATQ4 7 ATQ7 15 ATQ4-1/2 8 ATQ8 20 ATQ5 9 ATQ9 25 ATQ5-6/10 10 ATQ10 30 CATALOG NUMBER ATQ12 ATQ14 ATQ15 ATQ20 ATQ25 ATQ30 Melting Time — Current Data 4 - 30 Amperes, 500 Volts AC Time in Seconds Time in Seconds Melting Time — Current Data 1/10 - 3-1/2 Amperes, 500 Volts AC Current in Amperes Current in Amperes C2 AMP-TRAP® ATMR CLASS CC SMALL FUSE - BIG PROTECTION FOR GENERAL CIRCUITS Amp-trap ATMR fuses, in the Class CC family, are the smallest dimension 600V fuses suitable for branch circuit protection. The ATMR is a popular choice for economical protection of control circuits and control circuit transformers where available short circuit currents exceed 10,000 amperes. ATMR’s rejection dimensions prevent substitution by lesser rated fuses. These fast acting fuses give current limiting protection to general circuits. Features / Benefits ® Rejection style design prevents replacement errors when used with recommended fuse blocks ® Fiberglass body provides dimensional stability in harsh industrial environments ® Versatile design for individual component and branch circuit protection HIGHLIGHTS: APPLICATIONS: ® ® Fast Acting ® Very Current-Limiting Ratings ® AC: 1/10 to 30A 600VAC, 200kA I.R. Control Circuits ® Lighting ® General Loads ® Branch Circuit Protection CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1/10 1/8 ATMR1/10 ATMR1/8 3-1/2 4 ATMR3-1/2 ATMR4 2/10 1/4 ATMR2/10 ATMR1/4 5 6 ATMR5 ATMR6 3/10 1/2 3/4 ATMR3/10 ATMR1/2 ATMR3/4 7 8 9 ATMR7 ATMR8 ATMR9 1 1-1/4 ATMR1 ATMR1-1/4 10 12 ATMR10 ATMR12 1-1/2 2 2-1/2 ATMR-1-1/2 ATMR2 ATMR2-1/2 15 20 25 ATMR15 ATMR20 ATMR25 3 ATMR3 30 ATMR30 ® UL Listed to Standard 248-4 ® CSA Certified to Standard C22.2 No. 248.4 Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING Approvals B 28 AMP-TRAP® FAST ACTING / CLASS CC FUSES ATMR Recommended Fuse Blocks For Amp-Trap® Class CC Fuses Dimensions CATALOG NUMBER Number of Poles ULTRASA F E “ Indicating Fuse Holders Screw Connector with Double Quick Connects Pressure Plate Connector with Double Quick Connects ADDER 1 2 3 USCC1I USCC2I USCC3I 30310R 30311R 30312R 30313R 30320R 30321R 30322R 30323R Refer to the Class CC Fuse Block section of this catalog for other details. Current in Amperes Melting Time — Current Data, 600V Fuses ATMR1/10 to 30 Maximum Instantaneous Peak Let-Thru Amperes Time in Seconds Peak Let-Thru Current Data — ATMR3/4 to 30, 600 Volts AC Current in Amperes B 29 Copper Box Connector 30350R 30351R 30352R 30353R B AMP-TRAP® ATM 1-1/2" X 13/32" Amp-trap midget fast-acting ATM fuses are rated 600 volts AC, with a 100kA interrupting rating. These ratings give the ATM a wide range of applications not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and 30/50 amperes are offered for specific applications such as capacitor protection. These ATM fuses must still be considered 30A fuses because of their dimensions, but are able to withstand much higher inrush currents and tougher duty cycles. (Not for Branch Circuit Protection). HIGHLIGHTS: APPLICATIONS: ® Fast Acting ® ® Special Ratings (above 30A) Supplemental protection of a wide variety of circuits up to 600VAC and 500VDC with 100kA I.R. MIDGET FUSES Features / Benefits ® For supplemental protection of small motors and transformers ® Extended ratings for special protection of capacitors and circuits with high inrush currents ® 500VDC ratings for a wide variety of applications ® Can be used with ULTRASAFE™ fuse holders Ratings Approvals ® AC: 1/10 to 30A 600VAC, 100kA I.R.; 35 to 50A 600VAC, 10kA I.R. ® UL Listed to Standard 248-14 (1/10 to 30A) ® DC: 1/10 to 30A 500VDC, 100kA I.R. ® DC listed to UL Standard 248-14 (1/10 to 30A) ® CSA Certified to Standard C22.2 No. 248.14 (1/10 to 30A) Melting Time — Current Data 1/10 - 30/50 Amperes, 600 Volts AC Time in Seconds Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1/10 1/8 2/10 1/4 1/2 3/4 1 1-1/2 2 3 4 5 ATM1/10 ATM1/8 ATM2/10 ATM1/4 ATM1/2 ATM3/4 ATM1 ATM1-1/2 ATM2 ATM3 ATM4 ATM5 6 8 10 12 15 20 25 30 30/35 30/40 30/50 ATM6 ATM8 ATM10 ATM12 ATM15 ATM20 ATM25 ATM30 ATM30/35* ATM30/40* ATM30/50* * are not continuous current rated devises Current in Amperes C4