LED emergency exit sign from Channel Safety Systems LED LED Emergency Exit Sign The Forest Emergency Exit sign utilises LED technology with the added advantage of ‘self-test’ operation for low-cost, high power, emergency illumination. Features • • • • • • • • • • • Please note The Health and Safety Signs and Signals Regulations i, SI 341, introduced in 1996 to enact the EU Signs Directive ii, required that all text-only fire safety signs (i.e. EXIT or FIRE EXIT signs) produced to comply with BS 2560 should be replaced by 24th December 1998 with the pictogram format “running man” signs. Consideration should not only be given to updating signs by changing the legend panels or diffusers, but also to taking the opportunity to test the installed signage products. Testing will often reveal that the internal battery also needs replacing. Replacement of just the legend panels or diffusers may be difficult if the sign luminaire type has been discontinued by the maker. This, combined with the possible need to replace the internal battery, will usually mean that it is more cost effective to replace the whole luminaire. Image shows from left to right, Forest white ceiling pole mounted (E/CHFO/CPB/WH) and Forest brass chain mounted (E/CHFO/M3/L/BRST) 30mm 54mm Viewing Distance: (metres) 360mm 32m 180mm • Maintained or non-maintained 3 hour emergency backup (can be switched to non-maintained if required) Double sided legend, supplied as standard with arrow up Mounting brackets available in white metal, brass, chrome or satin Supplied with hanging chains and fixing bracket as standard Incorporates 4.8V NiCd battery Low environmental impact Minimal maintenance Meets BS EN 60598-2-22 and other relevant standards 250mm • Self-test operation as standard to BS EN 62034 Low running costs Uses 15 white LEDs Long life LED technology Lightweight & easy to install 8mm Please note image shown is not to scale and is for pictorial reference only SPECIFICATIONS Light Source 15 white LEDs IP Rating IP40 Emergency Duration 3 hours (minimum) Mains Voltage 230V 50Hz ± 10% Mains Current (max) 35mA (max) (8.5W) Recharge Period Less than 24 hours Charge Indicator Integral green LED Changeover Voltage As per requirements of BS EN 60598-2-22 Temperature Range -10oC to 55oC (non-condensing) Weight 1.5Kg Battery 4.8V NiCd PRODUCT CODE DESCRIPTION E/CHFO/M3/L/WHST Forest LED 3 hour maintained in white complete with 1m chain kit E/CHFO/M3/L/BRST Forest LED 3 hour maintained in brass complete with 1m chain kit E/CHFO/M3/L/CHST Forest LED 3 hour maintained in chrome complete with 1m chain kit E/CHFO/M3/L/SAST Forest LED 3 hour maintained in satin complete with 1m chain kit MOUNTING BRACKETS E/CHFO/CPB/WH Forest white ceiling pole bracket - poles are 280mm (not inc threads) E/CHFO/CPB/BR Forest brass ceiling pole bracket - poles are 280mm (not inc threads) E/CHFO/CPB/SI Forest satin/silver ceiling pole bracket - poles are 280mm (not inc threads) E/CHFO/WMB/WH Forest white wall mounting bracket E/CHFO/WMB/BR Forest brass wall mounting bracket E/CHFO/WMB/SI Forest satin silver wall mounting bracket E/CHFO/FMB/WH Forest white flag mounting bracket E/CHFO/FMB/BR Forest brass flag mounting bracket E/CHFO/FMB/SI Forest satin silver flag mounting bracket ADDITIONAL LEGENDS www.channelsafety.co.uk Tel: 0845 884 7000 Email: sales@channelsafety.co.uk S/LEG/FO/AU Double sided arrow up legend for Forest (insert only) S/LEG/FO/ALR Double sided arrow left/right for Forest (insert only) S/LEG/FO/AD Double sided arrow down legend for Forest (insert only) Errors & ommissions excluded. Specification is subject to change without notice. revision 013-1 CHANNEL SAFETY SYSTEMS t: 0845 884 7000 | w: www.channelsafety.co.uk INSTALLATION All Installations should be carried out by a competent electrician. 1. Remove the black end cap, 2. Slide the aluminium cover off, 3. Feed the AC wire through the hole on the top of the aluminium housing into the main body of the light 4. ISOLATE THE A.C. SUPPLY and connect unit. An unswitched 230V A.C. ± 10% supply must be connected to the live (L). Earth and neutral (N) terminals on the PCB block. When Maintained operation is required, illumination can be achieved by connecting a link between L’ and L either locally or through a remote switch, or by switching a ‘Live’ feed in to L’. 5. The battery is pre-connected. 6. Fit the ‘legend blade’ Refit the aluminium cover & black end cap. 7. Operational Check – Restore the A.C. Supply for 30 minutes and then remove. The LED’s should illuminate for at least 10 seconds. 8. Restore the A.C. supply and check that the indicator LED is ‘on’. 9. A method of testing the luminaire should be incorporated in the supply circuit. This should be installed to fail the un-switched supply. A key switch may be suitable (EN 60598-2-22:1998 22.20.1) INSTRUCTIONS - Issue 1 - 02/2014 | 2 CHANNEL SAFETY SYSTEMS t: 0845 884 7000 | w: www.channelsafety.co.uk OPERATION Non-Maintained LED’s normally off and battery on automatic charge (LED ‘on’) when A.C. Supply is healthy. Solid state circuitry automatically switches lamp on when A.C. supply is interrupted. Maintained Emergency LED’s normally on, when the supply to L’ is switched on. The battery is on automatic charge (LED ‘on’). Lamp will switch on or remain on if A.C. Supply is interrupted. Monitoring Green indicator lamp (LED) normally continuously ‘on’. Indicator lamp goes out if A.C. Supply or charger fails. Battery Sealed Nickel-Cadmium rechargeable battery pack. Temperature Performance figures measured at 25oC. Fault Finding And Corrective Action Monitoring Led Not Illuminated A.C. Supply not healthy. Battery not connected. Charger failed. Unit Not Meeting Required Emergency Period May need cycling: Discharge then recharge for 24 hours. Re-test, Battery pack may need replacing if emergency duration still not met. Environmental Parameters Rated performance limits: Temperature Min 5oC Max 25oC Humidity 80% max INSTRUCTIONS - Issue 1 - 02/2014 | 3 CHANNEL SAFETY SYSTEMS t: 0845 884 7000 | w: www.channelsafety.co.uk TESTING Recommended Routine Test Procedure The following test is designed to ensure the continued protection of your premises and occupants. Because of the possibility of a failure of the normal lighting supply occurring shortly after a period of testing, all tests should, whenever possible, be undertaken at times of least risk, e.g. during daylight hours. Once A Day Visual inspection of battery charge led. Once A Month Each unit should be energised from it’s battery for adequate time to ensure, by simulation of a failure of the normal lighting supply, the emergency mode is functioning correctly. Once Each Year All units should be placed into emergency mode and checked that the duration provided by the battery meets the specified time period. Forest ‘Self-Test’ • 20 hours after applying mains voltage a function test is automatically run (30 sec. The items checked are ‘emergency changeover and lamp. • After a further 4 hours, an automatic 3 hour duration test is run. (If the test button is pressed for 5 sec. before the duration test has ended, the test is aborted.) • Following the first duration test, regardless of whether or not this was passed, the weekly function test and yearly duration test are automatically started. Manual Operation TEST BUTTON GREEN LED STATUS Press for about 1 second OFF Emergency mode for 1 second Press for about 3 seconds Blinking Functional test for 30 seconds Press for about 5 seconds Flashing Duration test Press again for about 5 seconds Functional Interruption of duration test INSTRUCTIONS - Issue 1 - 02/2014 | 4 CHANNEL SAFETY SYSTEMS t: 0845 884 7000 | w: www.channelsafety.co.uk Meaning of the indicator LED Green Red The status display can only be cleared after the fault has been rectified, mains voltage has been reapplied and a function test has been run. Changing The Rechargeable Battery If the emergency duration is less than 180 min., the rechargeable battery has to be replaced. Use only original batteries from the manufacturer. INSTRUCTIONS - Issue 1 - 02/2014 | 5