Measuring instruments

advertisement
Pressure
Temperature
Humidity
Air
Measuring instruments
for ventilation and air-conditioning
Part of your business
Ability to meet any challenge
Our knowledge for your success
Made by WIKA
In the course of the last six decades the name WIKA has
become a symbol for sophisticated solutions in the field of
pressure and temperature measurement.
Our ever increasing ability is the basis for implementation of
innovative technologies in the form of reliable products and
efficient system solutions.
We owe our leading position in the world market to the consistent dedication towards premium quality, to which, today,
7,300 employees of the WIKA group of companies are committed. More than 500 experienced sales staff ensure that
our customers are individually and competently advised and
looked after from the outset.
Anywhere and any time.
The development and high-tech production in our owned
modern production facilities (Germany, Brazil, China, India,
Canada, Poland, Switzerland, South Africa and U.S.A.) is the
best warranty for our flexibility.
Whether SMD automatic insertion machines, CNC automatic
machining centres, welding robots, laser welding, sputterers,
thermotransfer printing or thin film production - we exploit all
possibilities to achieve above-average results. And the end
result: More than 43 million quality products are delivered
year in, year out, in more than 100 countries. Worldwide,
approximately 350 million WIKA measuring instruments are
in use.
Certified quality
The WIKA quality assurance management system has been
certified in accordance with ISO 9001 since 1994. The quality and safety standards of our company meet the standard
systems of several countries.
Fully automatic
production of measuring
instruments
The modern high-bay
warehouse ensures
efficient logistics
2
DKD/DAkkS accredited
calibration laboratories
for pressure and temperature
Contents
air2guide product range
4
Instrument requirement, application example
8
A2G-05 Eco differential pressure gauge
9
A2G-10 Differential pressure gauge
10
Differential pressure gauge with electrical
output signal
11
A2G-20 Air velocity and temperature transmitter
12
A2G-25 Air flow transmitter
13
A2G-30 Inclined tube manometer
14
A2G-40 Differential pressure switch
15
A2G-15
A2G-45
Electronic differential pressure switch with
display
16
A2G-50 Differential pressure transmitter
17
A2G-55 Eco differential pressure transmitter
18
A2G-60 Duct/immersion temperature sensor
19
A2G-61 Duct temperature sensor
20
A2G-65 Frost protection thermostat
21
A2G-70
Duct sensor for relative humidity and
temperature
22
A2G-80 Air quality sensor VOC
23
A2G-85 CO2 sensor
24
A2G-90
Differential pressure gauge Airbox with
differential pressure switch
Accessories
25
26
3
air2guide product range
Eco differential
pressure gauge
Differential
pressure gauge
Differential pressure
gauge with electrical
output signal
Air velocity and
temperature transmitter
Model
A2G-05
A2G-10
A2G-15
A2G-20
Application
For monitoring the
differential pressure of air
and other non-inflammable
and non-aggressive gases
For monitoring the
differential pressure of air
and other non-inflammable
and non-aggressive gases
For measuring the air
For monitoring the
velocity and temperature
differential pressure of air
of air and other nonand other non-inflammable
inflammable and nonand non-aggressive gases
aggressive gases
Installation
With mounting ring
With case
With case
With mounting flange
Measuring range
0 ... 50 Pa to
0 ... 12,500 Pa,/
-25 ... +25 Pa to
-1,500 ... +1,500 Pa,
further +/-ranges on
request
0 ... 50 Pa to
0 ... 12,500 Pa,
-25 ... +25 Pa to
-1,500 ... +1,500 Pa,
further +/-ranges on
request
0 ... 50 Pa to
0 ... 12,500 Pa,
-25 ... +25 Pa to
-1,500 ... +1,500 Pa,
further +/-ranges on
request
Air velocity:
0 ... 2 m/s, 0 ... 10 m/s or
0 ... 20 m/s
can be selected at the
instrument via jumpers
Temperature: 0 ... 50 °C
Units
Pa, kPa, In.WC,
mmWC, mbar
Pa, kPa, In.WC,
mmWC, mbar
Pa, kPa, In.WC,
mmWC, mbar
m/s, °C
Medium temperature
-16 ... +50 °C
-16 ... +50 °C
-16 ... +50 °C
0 ... +50 °C
Ambient temperature
-30 ... +80 °C
-30 ... +80 °C
-30 ... +80 °C
0 ... +50 °C
Accuracy class
±3 % FS
±5 % < 125 Pa
±3 % FS
±5 % < 125 Pa
±3 % FS
±5 % < 125 Pa
Air velocity:
FS 0 ... 2 m/s: < 0.1 m/s
+5 % of measured value
FS 0 ... 10 m/s: < 0.5 m/s
+5 % of measured value
FS 0 ... 20 m/s: < 1.0 m/s
+5 % of measured value
Temperature:
< 0.5 °C (v > 0.5 m/s)
Ingress protection
IP 54 (optional IP 65)
IP 54 (optional IP 65)
IP 54 (optional IP 65)
IP 54
Special
Depth 42 mm, with fixed
connections in angular
form for hoses of inner
Ø 4 mm or 6 mm
Two-part construction
(measuring element and
case)
Two-part construction
(measuring element and
case)
Easy to install
Data sheet
PM 07.42
PM 07.40
PV 17.40
SP 69.06
Details
See page 9
See page 10
See page 11
See page 12
4
air2guide product range
Air flow transmitter
Differential
Inclined tube manometer pressure switch
Electronic differential
pressure switch and
transmitter with display
Differential pressure
transmitter
A2G-25
A2G-30
A2G-40
A2G-45
A2G-50
For monitoring the
differential pressure of air
and other non-inflammable
and non-aggressive gases
For monitoring the
For monitoring the
differential pressure
differential pressure of air
of air and other nonand other non-inflammable
inflammable and nonand non-aggressive gases
aggressive gases
For measuring the
volume flow in ventilation
For monitoring ventilators,
ducts of air and other
blowers and filters
non-inflammable and nonaggressive gases
■■ -500
0 … 1,000 Pa
0 … 2,000 Pa
0 … 5,000 Pa
0 … 7,000 Pa
0 … 600 Pa
20 … 200 Pa to
500 … 4,500 Pa
... +500 Pa
(-100 ... +100 Pa,
-250 ... +250 Pa,
-300 ... +300 Pa)
- 50 ... +50 Pa to
or
0 ... 7,000 Pa
■■ 0 ... 2,500 Pa
(0 ...+100 Pa, 0 ...+250 Pa,
0 ... +1,000 Pa)
Pa, m3/s, m3/h, cfm, l/s,
psi, kPa, mbar, mmWC,
In.WC
Pa, In.WC, mmWC, mbar,
kPa
Pa, In.WC, mmWC, mbar,
kPa
Pa, In.WC, mmWC, mbar,
kPa
Pa, In.WC, mmWC, mbar,
kPa
-5 ... +50 °C
-40 ... +60 °C
-20 ... +60 °C
-10 ... +50 °C
(-5 ... +50 for AZ models)
-5 ... +50 °C
-20 ... +70 °C
-40 ... +60 °C
-40 ... +85 °C
-20 ... +70 °C
-20 ... +70 °C
0 ... 1,000 Pa,
0 ... 2,000 Pa:
±5 Pa ... ±1.5 % FS
0 ... 5,000 Pa,
0 ... 7,000 Pa:
±7 Pa ... ±1.5 % FS
5 Pa, 25 Pa
Lowest limits:
5 … 50 Pa
Highest limits:
20 … 200 Pa
±0.7 %
±1.5 %
(with measuring range
-50 ... +50 Pa: ±3 %)
IP 54
IP 54
IP 54
IP 54
IP 54
Easy to install,
easy-to-read display
Setting with K factor of the
standard orifice plate or
the ventilator
Easy to install,
easy-to-read scale
Robust case and easy to
install
Robust case and easy to
install
Up to 2 switch points
possible
Robust design, easy to
install
SP 69.04
PM 07.41
SP 69.02
SP 69.08
SP 69.03
See page 13
See page 14
See page 15
See page 16
See page 17
www.air2guide.com
5
air2guide product range
Eco differential
pressure transmitter
Duct/immersion
temperature sensor
Bimetal thermometer
Frost protection
Duct temperature sensor thermostat
Model
A2G-55
A2G-60
A2G-61
Application
For monitoring the
differential pressure of air
and other non-inflammable
and non-aggressive gases
For monitoring the
For measuring the temtemperature in
perature of gaseous media
ventilation systems and
in heating, ventilation and
in air-conditioning and
air-conditioning systems
refrigeration technology
For air-side temperature
control and prevention
of frost damage to water
heating coils in ventilation
and air-conditioning
systems
Measuring range
0 ... 250 Pa to
0 ... 5,000 Pa
0 ... 50 to 0 ... 250 °C
(active)
-50 ... 260 °C (passive)
-20 ... +60 °C
Adjustable range for
set point -10 ... +15 °C
(factory setting 5 °C)
Units
Pa, In.WC, mmWC, mbar,
kPa
°C
°C
°C
Operating
temperature
-10 ... +50 °C
-
-
-
Ambient temperature
-10 ... +50 °C
-35 ... +70 °C
-8 ... +70 °C
-8 ... +70 °C
Accuracy class
±2.0 % FS
± 1 % of measuring range
Class 2 per EN 13190
Switching differential
≤ 2 ... ±1 °C
Repeatability ±0.5 °C
Ingress protection
IP 65
IP 65
IP 42
IP 65
Special
Cost-effective alternative
to the standard instrument
A2G-50
Easy to install, direct
installation into the
process
Simple mounting
Passive: Pt1000 A DIN or
Ni1000
Active: 0 ... 10 V/4 ... 20 mA
Easy to install
Data sheet
SP 69.05
TE 62.90
TM 48.02
TE 62.92
Details
See page 18
See page 19
See page 20
See page 21
6
A2G-65
air2guide product range
Duct sensor for relative
humidity and temperature Air quality sensor VOC
CO2 sensor
Differential pressure
gauge with differential
pressure switch
A2G-70
A2G-80
A2G-85
A2G-90
For measuring the relative
humidity and temperature
of gaseous media in
heating, ventilation and
air-conditioning systems
For measuring the indoor
air quality, the greater the
output signal of the sensor
(0 ... 10 V), the worse the
air quality
For measuring the
CO2 content in rooms
For monitoring the
differential pressure of air
and other non-inflammable
and non-aggressive gases
and for controlling air and
fire shutters
Humidity: 0 ... 100 % rH
Temp.: -20 ... +80 °C
0 ... 10 V, load min. 10 kΩ
0 ... 2,000 ppm
0 ... 250 Pa to
0 ... 6,000 Pa
°C
Volt
Volt
Pa, In.WC, mWC, mbar,
kPa
-
-20 ... +50 °C
0 ... +50 °C
-16 ... +50 °C
-
-
-
-
±3 % between
20 ... 80 % rF,
temperature ±1 %
between 5 ... 45 °C
-
typically ±40 ppm + 4 % of
measured value
± 3 % of measuring range
IP 65 (connection head)
IP 20
IP 20
IP 54
Easy to install, direct
installation into the
process
Temperature 0 ... 10 V
(active)
RH 0 ... 10 V
Easy to install
Maintenance-free,
self-calibrating
Compact indicator and
pressure switch fitted
within a plastic case incl.
all connections
SP 62.91
SP 69.01
SP 69.07
PV 27.40
See page 22
See page 23
See page 24
See page 25
www.air2guide.com
7
Instrument requirement,
application example
Measuring instruments for ventilation and
air-conditioning (VAC)
WIKA measuring instruments for ventilation and airconditioning applications meet the highest demands,
since their development is based on the “value innovation”
philosophy, which involves comprehensive clarification of
market and customer requirements. The products, which
are very popular among users, are mainly designed for
the requirements of ventilation systems for industrial and
administrative premises, and for manufacturers of ventilation
and air-conditioning equipment. The instruments have to
be installed in line with the ventilation and air-conditioning
directive on filter monitoring and are available in all required
sizes and measuring ranges.
With air2guide, WIKA offers a comprehensive range of
measuring instruments for ventilation and air-conditioning
applications. The portfolio includes differential pressure
measuring instruments (mechanical and electronic), an
inclined tube manometer, a differential pressure switch and
a differential pressure transmitter. These instruments are
primarily used for monitoring filters and ventilators. In addition
an air flow meter and an air velocity transmitter for measuring
the volume flow and the air velocity in air ducts and airconditioning systems are available. Using a frost protection
thermostat additionally prevents frost damage to the heat
exchangers by monitoring the air-side temperature.
The two measuring instruments, the mechanical differential
pressure gauge and the mechanical differential pressure
gauge with analogue display and analogue output signal, are
identical in design.
In addition the duct/immersion temperature sensor and
the temperature and humidity sensor are available to
measure the temperature and humidity in ventilation and
air-conditioning systems. The airbox combination, which
consists of a mechanical differential pressure gauge and a
differential pressure switch, is suitable for filter monitoring.
The range is completed by an air quality sensor for volatile
organic compounds (VOC) and a CO2 sensor used to
measure the carbon dioxide content in the air.
Key benefits of the air2guide instruments:
„„ Easy to install and remove without tools
„„ Up to 50 % time saving during installation compared with
conventional models
„„ Advanced design, optimised packaging for the target
market
„„ First class delivery quality
air2guide application example
8
A2G-05
Eco differential pressure gauge
Model A2G-05
The A2G-05 differential pressure gauges are ideally suited
to the measurement of overpressure, negative pressure
and differential pressure in the measuring ranges 0 ... 50 to
0 ... 12,500 Pa and -25 ... +25 to -1,500 ... +1,500 Pa. The
benefit of the A2G-05 in comparison with other manufacturers’
differential pressure gauges lies in the 2-part construction
(design) of the gauge. The instruments are quick and easy
to install. The measuring element and the mounting ring are
separated. This has the advantage that, in case of repairs,
only the measuring element or the mounting ring has to be
replaced resulting in installation cost savings. Due to its small
mounting depth (42 mm) the A2G-05 is ideally suited for
installation in doors or walls of clean rooms.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Ventilator and blower
monitoring
„„ Differential pressure
monitoring in filters
„„ Overpressure monitoring
in clean rooms
Special features
„„ Easy to install and
remove
„„ Small installation depth
(42 mm), for recessed
installation in doors and
walls of clean rooms
„„ Integrated sealing
element for installation in
the air duct
Specifications A2G-05
Nominal size
110 mm
Measuring range
0 ... 50 Pa to 0 ... 12,500 Pa, -25 ... +25 Pa to -1,500 ... +1,500 Pa,
further +/- ranges on request, also available in the measuring units
kPa, in.WC, mmWC and mbar
Accuracy class
Permissible temperatures
Ingress protection
Process connection
Separating diaphragm
Built-in version
Ambient temperature: -30 … +80 °C
Medium temperature: -16 … +50 °C
Ingress protection IP 54 (optional IP 65)
Fixed connection in angular form for hoses of inner Ø 4 mm
or 6 mm
Silicone
Movement
Contact-free transmission, (SWISS MOVEMENT)
Pointer
Plastic (red mark pointer, optional)
Basic case, case for panel/
wall mounting
Glass-fibre reinforced plastic
Dial
Aluminium
Window
Makrolon (UV stabilised)
Standard accessories
Data sheet
www.air2guide.com
±3 % (±5 % with scale range ≤ 0 ... 125 Pa)
3 mounting screws,
for further accessories see page 26
PM 07.42
9
A2G-10
Differential pressure gauge
Model A2G-10
The A2G-10 differential pressure gauges are ideally suited
to the measurement of overpressure, negative pressure
and differential pressure in the measuring ranges 0 ... 50 to
0 ... 12,500 Pa and -25 ... +25 to -1,500 ... +1,500 Pa. The
benefit of the A2G-10 in comparison with other manufacturers’
differential pressure gauges lies in the 2-part construction
(design) of the gauge. The instruments are quick and easy to
install. The measuring element and case (built-in and add-on
version) are separate. This has the advantage that, in case
of repairs, only the measuring element or the case has to be
replaced resulting in installation cost savings.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Ventilator and blower
monitoring
„„ Differential pressure
monitoring in filters
„„ Overpressure monitoring
in clean rooms
Special features
„„ Easy to install and
remove
„„ 2-part construction
(measuring element and
case)
„„ Standard accessories
included
„„ Integrated sealing
element for installation in
the air duct
Built-in version
Specifications A2G-10
Nominal size
110 mm
Measuring range
0 ... 50 Pa to 0 ... 12,500 Pa, -25 ... +25 Pa to -1,500 ... +1,500 Pa,
further +/- ranges on request, also available in the measuring units
kPa, in.WC, mmWC and mbar
Accuracy class
Permissible temperatures
Ingress protection
10
Ambient temperature: -30 … +80 °C
Medium temperature: -16 … +50 °C
IP 54 (optional IP 65)
Process connection
G ⅛ female, for hoses of inner Ø 4 mm or 6 mm
Movement
Contact-free transmission (SWISS MOVEMENT)
Pointer
Plastic (red mark pointer, optional)
Basic case, case for panel
and wall mounting
Glass-fibre reinforced plastic
Separating diaphragm
Silicone
Dial
Aluminium
Window
Makrolon (UV stabilised)
Standard accessories
Add-on version
±3 % (±5 % with scale range ≤ 0 ... 125 Pa)
Data sheet
3 mounting screws/Straight or angular threaded pressure
connections G ⅛ for inner Ø 4 mm or 6 mm, for further
accessories see page 26
PM 07.40
A2G-15
Differential pressure gauge with electrical
output signal
Model A2G-15
In addition to the analogue display, the A2G-15 also has an
analogue output signal. The A2G-15 is available with a 3-wire
output signal (0 ... 10 V). It is mainly used where, in addition
to an on-site display, the measured data is also continually
obtained, registered and processed, or used as a control
signal for ventilation and air-conditioning systems. The instruments are quick and easy to install. The measuring element
and case (built-in and add-on version) are separate. This has
the advantage that, in case of repairs, only the measuring
cost savings.
Applications
„„ For monitoring the differ-
ential pressure of air and
other non-inflammable
and non-aggressive
gases
„„ Ventilator and blower
monitoring
„„ Differential pressure
monitoring in filters
„„ Overpressure monitoring
in clean rooms
Special features
„„ Easy to install and
„„
„„
„„
„„
remove
Output signal 0 … 10 V,
3-wire
Same dimensions as the
mechanical version
2-part construction
(measuring element and
case)
Integrated sealing
element for installation in
the air duct
Built-in version
Add-on version
Specifications A2G-15
Nominal size
110 mm
Measuring range
0 ... 50 Pa to 0 ... 12,500 Pa, -25 ... +25 Pa to -1,500 ... +1,500 Pa,
further +/- ranges on request, also available in the measuring units
kPa, in.WC, mmWC and mbar
Accuracy class
Permissible temperatures
Ingress protection
Ambient temperature: -30 … +80 °C
Medium temperature: -16 … +50 °C
IP 54 (optional IP 65)
Process connection
G ⅛ female, for hoses of inner Ø 4 mm or 6 mm
Movement
Contact-free transmission (SWISS MOVEMENT)
Pointer
Plastic (red mark pointer, optional)
Basic case, case for panel/
wall mounting
Glass-fibre reinforced plastic
Separating diaphragm
Silicone
Dial
Aluminium
Window
Makrolon (UV stabilised)
Output signal
0 … 10 V, 3-wire
Electrical connection
Cable gland M12
Power supply UB
DC 15 … 35 V
Standard accessories
Cable gland M12, 3 mounting screws/Straight or angular threaded
pressure connections G ⅛ for inner Ø 4 mm or 6 mm, for further
accessories see page 26
Data sheet
www.air2guide.com
±3 % (±5 % with scale range ≤ 0 ... 125 Pa)
PV 17.40
11
A2G-20
Air velocity and temperature transmitter
Model A2G-20
The A2G-20 (air velocity transmitter) is used for measuring
air velocity and temperature in gaseous media of heating,
ventilation and air-conditioning systems (e.g. fresh air/
exhaust air ducts). The air velocity transmitter is designed for
connection to control and display systems.
Applications
„„ For measuring the
air velocity and the
temperature of air and
other non-inflammable
and non-aggressive
gases in fresh air or
exhaust air ducts
„„ Designed for connection
to control and display
systems
Special features
„„ Simple mounting
„„ Very reliable
„„ Three measuring
ranges adjustable at the
instrument via jumpers
„„ Two output signals in one
instrument
„„ Standard accessories
included
Specifications A2G-20
Accuracy
Temperature: < 0.5 °C (v > 0.5 m/s)
Measuring range
Permissible temperatures
Ingress protection
Output signal
Supply voltage
Air velocity:
0 ... 2 m/s, 0 ... 10 m/s or 0 ... 20 m/s can be selected at the
instrument via jumpers
Temperature: 0 ... 50 °C
Ambient temperature: -0 … +50 °C, max. 85 % rH
Medium temperature: -0 … +50 °C, max. 85 % rH
IP 54
Air velocity:
0 … 10 V (linear to m/s): Load min. 1 kΩ or
4 … 20 mA (linear to m/s): Load max. 400 Ω
Temperature:
0 … 10 V (linear to °C): Load min. 1 kΩ or
4 … 20 mA (linear to °C): Load max. 400 Ω
DC 24 V/AC 24 V ±10 %
Weight
220 g
Case
Plastic (ABS)
Measuring element
Pt1000 and NTC10k
Electrical connection
Screw terminals, max. 1.5 mm²
Cable gland M16
Type of mounting
Standard accessories
Data sheet
12
Air velocity:
Meas. range 0 … 2 m/s: < 0.1 m/s +5 % of measured value
Meas. range 0 ... 10 m/s: < 0.5 m/s +5 % of measured value
Meas. range 0 ... 20 m/s: < 1.0 m/s +5 % of measured value
Duct installation
Mounting flange,
for further accessories see page 26
SP 69.06
A2G-25
Air flow transmitter
Model A2G-25
The A2G-25 for measuring the volume flow is based on the
differential pressure value measured directly in the ventilator.
With the help of the K factor and the measured differential
pressure the volume flow is automatically calculated. The
instrument can be used for displaying the air quantity on site
or for sending the output value to a control system. With the
A2G-25 volume flows of up to 200,000 m3/h can be measured.
Applications
„„ For measuring the
volume flow in ventilation
ducts of air and other
non-inflammable and
non-aggressive gases
„„ For measuring,
monitoring and
controlling the air volume
flow of centrifugal
ventilators
„„ For operating fans/
ventilators from various
manufacturers
Special features
„„ Simple mounting
„„ User-friendly display
„„ Easy-to-read LCD
display
„„ Temperature
compensated
„„ Compact and robust
design
„„ Standard accessories
included
Specifications A2G-25
Accuracy
Measuring range
Permissible temperatures
Ingress protection
Output signal
0 … 1,000 Pa, 0 … 2,000 Pa, 0 … 5,000 Pa, 0 … 7,000 Pa
Ambient temperature: -10 ... +50 °C
Medium temperature: -5 … +50 °C
IP 54
V OUT DC 0…10 V ,
load R minimum 1 kΩ linear to the set output unit
P OUT DC 0…10 V,
load R minimum 1 kΩ linear to the set output unit
Supply voltage
AC 24 V or DC 24 V ±10 %
Process connection
For hoses of inner Ø 4 mm or 6 mm
Case
Plastic (ABS), cover polycarbonate (PC)
Type of mounting
Wall mounting
Weight
150 g
Measuring element
Piezo measuring cell
Electrical connection
Cable gland M16/cover PG, screw terminals max. 1.5 mm2
Standard accessories
2 mounting screws
Data sheet
www.air2guide.com
0 ... 1,000 Pa: ±5 Pa ... ±1.5 % of display
0 ... 2,000 Pa: ±5 Pa ... ±1.5 % of display
0 ... 5,000 Pa: ±7 Pa ... ±1.5 % of display
0 ... 7,000 Pa: ±7 Pa ... ±1.5 % of display
SP 69.04
13
A2G-30
Inclined tube manometer
Model A2G-30
The A2G-30 is suitable for applications where overpressure,
negative pressure and differential pressure have to be measured continually and accurately. Precise zero adjustment is
undertaken by changing the volume using a knurled screw.
The manometer is specially designed to prevent leakage of
the indicator fluid in the case of overpressure.
The manometer should be screwed in place on a suitable
vertical surface. The instrument is fixed in place and levelled
horizontally using the attached self-tapping screws.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Monitoring of ventilators,
blowers and filters in airconditioning and clean
room applications
„„ Overpressure monitoring
in clean rooms and
laboratories
Special features
„„ Easy to install
„„ Leakage protection
„„ Easy-to-read scale
„„ Standard accessories
included
Specifications A2G-30
Accuracy
5 Pa/25 Pa
Permissible temperatures
-40 ... +60 °C
Process connection
For hoses of inner Ø 4 mm or 6 mm
Case cover
Plastic
Sealing
NBR
Measuring range
0 ... 600 Pa
Max. pressure
200 kPa (2 bar)
Case
Plastic
Screws
Plastic
Standard accessories
2 mounting screws , filling liquid 30 ml , red and green pressure
limitation stickers, for further accessories see page 26
Data sheet
14
PM 07.41
A2G-40
Differential pressure switch
Model A2G-40
The A2G-40 is an adjustable differential pressure switch and
is used for monitoring the overpressure, negative pressure
or differential pressure of air or other non-inflammable and
non-aggressive gases. The adjustment knob at the case
enables convenient setting of the switch points on site. The
switching function is accomplished by an N/O contact or an
N/C contact.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Monitoring of air filters,
blowers, industrial
cooling air circuits, flows
in ventilation ducts and
the control of air and fire
shutters
„„ Overpressure monitoring
in clean rooms and
laboratories
Special features
„„ Easy to install and
assemble
„„ Robust case and
practical design
„„ Very reliable
„„ Standard accessories
included
Specifications A2G-40
Accuracy of the switch point
Switching differential
Measuring range
Permissible temperatures
Ingress protection
10 ... 180 Pa
Lowest limit
±5 Pa ...
±5 Pa ...
±5 Pa ...
±5 Pa ...
±10 Pa ...
±50 Pa ...
Highest limit
±20 Pa
±30 Pa
±30 Pa
±30 Pa
±50 Pa
±200 Pa
20 ... 200 Pa, 30 ... 300 Pa, 30 ... 500 Pa, 40 ... 600 Pa,
100 ... 1,500 Pa, 500 ... 4,500 Pa
Ambient temperature: -40 ... +85 °C
Medium temperature: -20 ... +60 °C
IP 54
Contact rating
2A/AC 250 V
Process connection
For hoses of inner Ø 4 mm or 6 mm
Case
Plastic
Sealings
Plastic
Type of mounting
Wall mounting
Data sheet
SP 69.02
Weight
150 g
Diaphragm
Silicone
Window
Polycarbonate
Electrical connection
Cable gland M16, screw terminals max. 1.5 mm2
Standard accessories
www.air2guide.com
20 ... 200 Pa
30 ... 300 Pa
30 ... 500 Pa
40 ... 600 Pa
100 ... 1,500 Pa
500 ... 4,500 Pa
2 mounting screws, for further accessories see page 26
15
A2G-45
Electronic differential pressure switch and
transmitter with display
Model A2G-45
The A2G-45 is an electronic differential pressure switch
for monitoring the differential pressure of air and other
non-inflammable and non-aggressive gases. It is used for
monitoring and switching pressures in facility management,
air-conditioning and clean room systems.
Applications
„„ Monitoring of air filters,
blowers, industrial
cooling air circuits, flows
in ventilation ducts
„„ Control of air and fire
shutters, frost protection
for heat exchangers
„„ Overpressure monitoring
in clean rooms and
laboratories
Special features
„„ Simple mounting
„„ Compact and robust
design
„„ Simple setting of up to
two switch points
Specifications A2G-45
Accuracy class
1.5 %
Measuring range
Four measuring ranges can be selected at the instrument via
jumpers
Variant 1:
-500 … +500 Pa *
-300 … +300 Pa **
-250 … +250 Pa **
-100 … +100 Pa **
Variant 2:
0 … 2,500 Pa *
0 … 1,000 Pa **
0 … 250 Pa **
0 … 100 Pa **
(For measuring ranges below 250 Pa the automatic zero
adjustment is recommended) (AZ)
Option: Automatic zero adjustment (AZ), 2 relay outputs (2R),
automatic zero adjustment and 2 relay outputs (AZ-2R)
Permissible temperatures
Ingress protection
IP 54
Output signal
0 … 10 V, load resistance min. 1 kΩ, 1 relay output
Weight
150 g
Measuring element
Piezo measuring cell
Electrical connection
Cable gland M16 and M20, screw terminals max. 1.5 mm2
Standard accessories
2 mounting screws, for further accessories see page 26
Power supply UB
AC 24 V ±10 % or DC 21 ... 35 V
Process connection
For hoses of inner Ø 4 mm
Case
Plastic (ABS), plastic (PC)
Type of mounting
Wall mounting
Data sheet
* Standard ** Jumper
16
Ambient temperature: -20 ... +70 °C, 95 % rH, non-cond.
Medium temperature: -10 ... +50 °C (-5 ... +50 °C for AZ models)
SP 69.08
A2G-50
Differential pressure transmitter
Model A2G-50
The A2G-50 is an electronic differential pressure transmitter
based on the piezo-resistive measuring principle. This
compact differential pressure transmitter offers excellent
performance and high quality at an attractive price. The
A2G-50 is characterised by convenient handling – regarding
the installation of the instrument and the readjustment of the
zero point. Various measuring ranges can be selected via
jumpers.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Monitoring of air filters,
blowers, industrial
cooling air circuits, flows
in ventilation ducts and
the control of air and fire
shutters
„„ Overpressure monitoring
in clean rooms and
laboratories
Specifications A2G-50
Accuracy class
Special features
„„ Easy to install and
„„
„„
„„
„„
„„
„„
„„
„„
remove
Very reliable
Adjustable response time
Zeroing by push button
Compact and robust
design
Standard accessories
included
Eight measuring ranges
adjustable at the
instrument via jumpers
Two output signals in one
instrument
LCD display (optional)
Measuring range
±1.5 %
Variant 1:
0 … 2,500 Pa *
0 … 2,000 Pa **
0 … 1,500 Pa **
0 … 1,000 Pa **
0 … 500 Pa **
0 … 250 Pa **
0 … 100 Pa **
-100 … +100 Pa **
Variant 2:
0 … 7,000 Pa *
0 … 5,000 Pa **
0 … 4,000 Pa **
0 … 3,000 Pa **
0 … 2,500 Pa **
0 … 2,000 Pa **
0 … 1,500 Pa **
0 … 1,000 Pa **
Eight measuring ranges can be
selected at the instrument via jumpers
(For measuring ranges below 250 Pa
the automatic zero adjustment is
recommended)
Variant 3:
-250 ... +250 Pa *
-100 ... +100 Pa **
-50 ... +50 Pa **
-25 ... +25 Pa **
0 ... 250 Pa **
0 ... 100 Pa **
0 ... 50 Pa **
0 ... 25 Pa **
Eight measuring
ranges can be selected
via jumpers
(Only available
with automatic zero
adjustment) (AZ)
Option: Digital indicator (D), automatic zero adjustment (AZ),
digital indicator and automatic zero adjustment (AZ-D)
Permissible temperatures
Ingress protection
Ambient temperature: -20 ... +70 °C
Medium temperature: -10 ... +50 °C
IP 54
Output signal
DC 0 … 10 V, 3-wire, 4 … 20 mA, 3-wire
Weight
150 g
Measuring element
Piezo measuring cell
Electrical connection
Cable gland M16, screw terminals max. 1.5 mm2
Standard accessories
2 mounting screws, for further accessories see page 26
Power supply UB
AC 24 V or DC 24 V
Process connection
For hoses of inner Ø 4 mm or 6 mm
Case
Plastic
Type of mounting
Wall mounting
Data sheet
SP 69.03
* Standard ** Jumper
www.air2guide.com
17
A2G-55
Eco differential pressure transmitter
Model A2G-55
The A2G-55 is an electronic differential pressure transmitter
based on the piezo-resistive measuring principle. This
compact differential pressure transmitter is a cost-effective
version of the standard transmitter. It is reduced to a limited
number of basic functions, but anyhow this instrument is
characterised by precision, high quality and convenient
handling. Only positive differential pressures can be
measured.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Monitoring of air filters,
blowers, industrial
cooling air circuits, flows
in ventilation ducts and
the control of air and fire
shutters
Special features
„„ Easy to install and
remove
„„ Maintenance-free
„„ Output signal 0 ... 10 V
„„ Compact and robust
design
Specifications A2G-55
Accuracy
Measuring range
Permissible temperatures
Ingress protection
0 ... 250 Pa
0 ... 500 Pa
0 ... 750 Pa
0 ... 1,000 Pa
0 ... 1,250 Pa
0 ... 2,500 Pa
0 ... 3,750 Pa
0 ... 5,000 Pa
Ambient temperature: -10 ... +50 °C
Medium temperature: -10 ... +50 °C
IP 65
Output signal
0 … 10 V (4 … 20 mA optional)
Weight
250 g
Measuring element
Piezo measuring cell
Electrical connection
Cable gland M16, screw terminals max. 1.5 mm2
Standard accessories
Without, for further accessories see page 26
Supply voltage
DC 13 ... 32 V
Process connection
For hoses of inner Ø 5.5 mm
Case
Plastic
Type of mounting
Vertical wall mounting
Data sheet
18
±2.5 % FS
SP 69.05
A2G-60
Duct/immersion temperature sensor
Model A2G-60
The A2G-60 duct/immersion temperature sensor is fitted
with the two sensors Pt1000 and Ni1000 and is mainly used
in ventilation, cooling and air-conditioning systems. Optionally
the transmitter is available with a 0 ... 10 V (TRV) or
4 ... 20 mA (TRA) output signal. The temperature sensors are
made from high quality materials using the latest production
methods. In order to protect the sensors in the temperature
sensors from moisture and mechanical overloading, they
can be coated with an SI protection (process using epoxy
enamelling powder).
Applications
„„ For measuring the
temperature of gaseous
media in heating,
ventilation and airconditioning systems
„„ Designed for connection
to control and display
systems
„„ In combination with a
stem also suitable for
measuring liquid media
(e.g. in pipeline systems)
Special features
„„ Simple mounting
„„ Incl. mounting flange
„„ Compact and robust
„„ Direct installation into the
process
Specifications A2G-60
Temperature sensor passive/Pt 1000 A DIN and Ni1000
Standard: -50 ... +160 °C
High temperature version: -50 ... +260 °C
Measuring range
Transmitter output
Power consumption
Accuracy
Permissible temperatures
Sensor sleeve material
Ranges transmitter active (TRV/TRA)
0 … +50 °C *
-50 … +50 °C **
-15 … +35 °C **
-15 … +35 °C **
-10 … +120 °C **
0 … +160 °C **
0 … +250 °C **
TRV 0 ... 10 V, min. load 5 kΩ, terminal, 3-pin (3-wire), or TRA
4 ... 20 mA (2-wire)
Model 0.35 W/0.82 VA
± 1 % of measuring range
Head temperatures
-35 … +90 °C passive (Pt1000 A DIN and Ni1000)
-35 … +70 °C active (TRV and TRA)
Sensor sleeve
Standard: -50 … +160 °C
High temperature version: -50 ... +260 °C
Stainless steel 1.4571
Ingress protection
IP 65
Electrical connection
Cable gland M16
Data sheet
TE 62.90
Insertion length L
192 mm, Ø = 7 mm, option L= 62, 135, 240, 320, 392, 465 mm
Weight
150 g
* Standard ** Jumper
www.air2guide.com
19
A2G-61
Bimetal thermometer
Duct temperature sensor
Model A2G-61
The A2G-61 bimetal duct temperature sensor with analogue
display is used for monitoring temperature in ventilation
systems.
Applications
„„ Monitoring of the
temperature in ventilation
systems
Special features
„„ Simple mounting
„„ No power supply
„„ With mounting template
Specifications A2G-61
20
Accuracy
Class 2 per EN 13190
Measuring element
Bimetal coil
Case
Aluminium
Window
Clear non-splintering plastic
Connection form
Front bezel with 3 mounting screws
Zero adjustment
At bottom of stem
Scale range
-20 ... +60 °C
Ingress protection
IP 42 per EN 60529
Front bezel
Aluminium, anodised, colourless
Sensor sleeve
Brass, not sealed, ∅ 9 mm
Insertion length
160 mm
Data sheet
TM 48.02
A2G-65
Frost protection thermostat
Model A2G-65
The A2G-65 (frost protection thermostat) is used for air-side
temperature control and prevention of frost damage to water
heating coils in ventilation and air-conditioning systems. It
is characterised by a high switching differential and a high
repeatability. The reset is done automatically.
Through the switching of the frost protection thermostat,
the following frost protection measures, for example, can
be initiated: Ventilator OFF, external air damper CLOSED, heating coil valve 100 % OPEN, air heat pump ON, chiller
(condenser) and air humidifier OFF. Activation of the visible
and/or audible frost warning alarm.
Applications
„„ For air-side temperature
control and prevention
of frost damage to
water heating coils in
ventilation and airconditioning systems.
Special features
„„ Small switching
differential
„„ High repeatability
„„ Automatic resetting
Specifications A2G-65
Adjustable range for set point
-10 … +15 °C (factory setting: 5 °C)
Repeatability
±0.5 °C
Capillary tube length
3 m (standard), 1.8 m or 6 m
Switching differential
2 ±1 °C
Sensor response length
Approx. 60 cm
Switching output
Change-over contact, max. AC 250 V, max. 10 A
Contact material:
Ag/Ni (90 % / 10 %), gold-plated 3 µm
Resetting
Screw terminal max. 2.5 mm2
Ingress protection
IP 65
Cable entry
Permissible temperatures
Case
Capillary tube
Data sheet
www.air2guide.com
Automatic
Terminal
Cable gland M16 x 1.5
Ambient temperature: -30 … 70 °C/max. 85 % rH, non-cond.
Medium temperature: W+ min. 2 K …70 °C
(W = selected set point)
Material lower body: PA GK30
Material cover: ABS transparent
Material: Copper
Capillary tube filling: R 507
TE 62.92
21
A2G-70
Duct sensor for relative humidity and
temperature
Model A2G-70
The measurement of relative humidity and medium temperature is becoming increasingly important in control systems.
Humidity- and temperature-controlled ventilation systems are
also being increasingly used in air-conditioning and ventilation applications. This measuring instrument determines
the relative humidity and the temperature of the ambient
air or the air in a duct by means of a capacitive sensor with
integrated temperature measurement. The sensor signals are
transformed into standard output signals and made available
for further processing. The sensor element is protected by a
sinter filter.
Applications
„„ For measuring the relative
humidity and temperature of gaseous media in
heating, ventilation and
air-conditioning systems
„„ Designed for connection
to control and display
systems
Special features
„„ Simple mounting
„„ Compact and robust
„„ Direct installation into the
process
„„ Incl. mounting flange
Specifications A2G-70
Power supply UB
Measuring range
Transmitter output
Power consumption
Accuracy
Permissible temperatures
Ingress protection
Insertion length L
Humidity: 5 ... 95 % rH (working range 0 ... 100 %)
Temperature: -20 ... +80 °C
Humidity: DC 0 ... 10 V, load: min. 5 kΩ
Temperature: DC 0 ... 10 V, load: min. 5 kΩ
0.5 W/1.7 VA
Humidity: ±3 % between 20 ... 80 % rH
Temperature: ±1 % of measuring range
Ambient temperature: -20 ... +70 °C
Sensor tip: max. 60 °C
Connection head IP 65
130 mm, option: 270, 480 mm
Electrical connection
Cable gland M16
Sensor tube
PVC, black
Terminal
Screw terminal max. 1.5 mm2
Filter element
Stainless steel, mesh width 80 µm
Data sheet
TE 62.91
Connection head
22
DC 15 ... 24 V/AC 24 V ±10 %
PA6, white
} Optional 4 ... 20 mA
A2G-80
Air quality sensor VOC
Model A2G-80
The A2G-80 measures volatile organic compounds in the
air. VOC, volatile organic compounds, is the collective name
for organic substances suspended in the air like gases or
vapours. VOCs include scent and taste particles, tobacco
smoke, building chemicals, solvents, disintegrating gases and
products of oxidation. VOCs therefore come from a variety of
sources.
The A2G-80 is a sensitive, cost-effective sensor for measuring
air quality. This module uses micro-metallic oxide semiconductor (MOS) technology for the detection of a variety of
volatile organic compounds.
Applications
„„ For measuring the indoor
air quality. The greater
the output signal of the
sensor (0 ... 10 V), the
worse the air quality.
„„ Mixed-gas sensors detect gases and vapours
which can be oxidised
(burned): body odours,
tobacco smoke, extracts
from materials (furniture,
carpets, paint coatings,
adhesives, etc.)
„„ In applications where air
quality is essential, e.g.
buildings, offices, classrooms, kitchens etc.
Special features
„„ The set point for the required air quality can be
preset on installation.
„„ Low consumption reduces energy costs.
www.air2guide.com
Specifications A2G-80
Power consumption
1.2 W/2.2 VA
Warm-up time
30 minutes
Humidity range
Max. 85 % rH, non-condensing
Weight
150 g
Output signal
0 ... 10 V, load min. 10 kΩ
Permissible temperatures
Ambient temperature: -20 ... +50 °C
Ingress protection
IP 20
Data sheet
SP 69.01
23
A2G-85
CO2 sensor
Model A2G-85
The A2G-85 measures the carbon dioxide content in rooms.
Wherever people are staying in rooms, the CO2 content is
an evident indicator for the indoor air quality. The higher the
CO2 content, the worse the air quality in the rooms. For the
CO2 measurement the “Non Dispersive InfraRed (NDIR)”
technology with automatic self-calibration is used. For direct
connection to a DDC (digital data controller) or a monitoring
system analogue 0 … 10 V outputs are available.
Applications
„„ For measuring the CO2
content in rooms
Special features
„„ Simple mounting
„„ Compact and robust
„„ Direct installation into the
process
Specifications A2G-85
Voltage supply
DC 15 ... 24 V (±10 %) or AC 24 V (±10 %) (SELV)
Terminals
Screw terminal, max. 1.5 mm2
CO2 sensor
0 ... 2,000 ppm
Power consumption
Max. 3 W/max. 6 VA
Output signal
CO2, 0 ... 10 V, load max. 10 mA
Temperature dependency
Accuracy at 21°C
CO2: Typically ±40 ppm +4 % of measured value
Insertion length
300 mm, Ø 30 mm, incl. mounting flange
Permissible temperatures
Ambient temperature:
0 ... +50 °C, max. 85 % rH non-condensing
Medium temperature
0 ... +50 °C, max. 85 % rH non-condensing
Case
Ingress protection
Weight
Data sheet
24
CO2: < 0.2 % of full scale value per °C
Plastic with cover crystal-clear 120 x 120 x 85 mm
IP 20
1.3 kg
SP 69.07
A2G-90
Differential pressure gauge Airbox with
differential pressure switch
Model A2G-90
The A2G-90 is a combination of a mechanical analogue
indicator and a differential pressure switch, which have been
fitted within a plastic case. The case is made from PC/ABS
1625 plastic (H x W x D = 240 x 191 x 110 mm) and with all
connections built in. The cover is screwed on. The ingress
protection is IP 54. The A2G-90 is ideally suited for the
measurement and switching of overpressures and differential pressures in the measuring ranges from 0 ... 250 to
0 ... 6,000 Pa.
Applications
„„ For monitoring the
differential pressure
of air and other noninflammable and nonaggressive gases
„„ Monitoring of air filters,
blowers, industrial
cooling circuits, flows
in ventilation ducts and
the control of air and fire
dampers
Special features
„„ Compact indicator and
pressure switch fitted
within a plastic case
(Airbox)
„„ Single pole micro switch
(change-over contact)
„„ Switch point adjustable
when installed
„„ All connections already
pre-assembled
Specifications A2G-90
Case
Plastic PC/ABS 1625 (H × W × D = 240 × 191 × 110 mm)
Cover
screwed
Pressure connections
Bulkhead quick connector for hose (4 or 6 mm inner diameter),
top mount connection
Ingress protection
Electrical connection
Permissible temperature
Data sheet
IP 54 per EN 60529/IEC 529
Angular connector DIN 43650, 3-pin + PE
Ambient: -30 … +60 °C
Medium: -16 … +50 °C
PV 27.40
Specifications A2G-10 mechanical differential pressure gauge
Accuracy
Measuring range
Data sheet
± 3 % of measuring range
0 … 250 Pa, 0 … 500 Pa, 0 … 750 Pa, 0 … 1,500 Pa, 0 … 2,000 Pa,
0 … 6,000 Pa
PV 07.40
Specifications A2G-40 differential pressure switch
Measuring range
Data sheet
www.air2guide.com
20 … 200 Pa, 30 … 300 Pa, 30 … 500 Pa, 40 … 600 Pa,
100 … 1,500 Pa, 500 … 4,500 Pa
SP 69.02
25
air2guide accessories
1
2
3
4
5
7
8
9
10
11
Description
1
2
3
4
5
6
Built-in case
Add-on case
Threaded bezel
Mounting ring
Adapter ring
Duct connector
7
8
9
10
E-No.
40195554
A2G-10
40195571
A2G-15
40195562
A2G-15
A2G-10, A2G-15
A2G-05
A2G-10, A2G-15
A2G-05, A2G-10, A2G-15,
A2G-30, A2G-40, A2G-45,
A2G-50, A2G-55
A2G-05, A2G-10, A2G-15,
A2G-30, A2G-40, A2G-45,
A2G-50, A2G-55
A2G-10, A2G-15
Cable gland M12
A2G-15
Screw fitting
Specifications
A2G-10
Threaded pressure
connection
A2G-10, A2G-15
Combi tube connection
A2G-10, A2G-15
Measuring tubes
A2G-05, A2G-10, A2G-15,
A2G-30, A2G-40, A2G-45,
A2G-50, A2G-55
A2G-05, A2G-10, A2G-15,
A2G-45
A2G-05, A2G-10, A2G-15,
A2G-30, A2G-40, A2G-45,
A2G-50, A2G-55
A2G-05, A2G-10, A2G-15,
A2G-45
11
26
Model
6
40195597
Mounting ring
Matching with threaded bezel 40217477
40217477
40371212
40229424
4 mm
40217507
6 mm
40217531
Straight Ø 4 mm
Straight Ø 6 mm
Angled Ø 4 mm
Angled Ø 6 mm
Set: 2 × angled and 2 × straight 4 mm
Set: 2 × angled and 2 × straight 6 mm
Set: 2 × angled 4 mm and 2 × angled 6 mm
Set: 2 × straight 4 mm and 2 × straight 6 mm
Straight Ø 4 mm with restrictor
Straight Ø 6 mm with restrictor
Angled Ø 4 mm with restrictor
Angled Ø 6 mm with restrictor
40179958
40179966
40179974
40179982
40217728
40217736
40217744
40217752
40241491
40241513
40241483
40241505
With mounting thread G ⅛ for pipes 6.35 mm/¼"
40232867
With mounting thread G ⅛ for inner tube diameter =
4 … 7 mm
40141241
40232484
PVC tube inner Ø 4 mm/roll at 25 m
40217841
PVC tube inner Ø 6 mm/roll at 25 m
40217850
Silicone tube inner Ø 4 mm/roll at 25 m
40208940
Silicone tube inner Ø 6 mm/roll at 25 m
40208958
air2guide accessories
12
13
Description
12
Mounting screws
13
Mounting flange
14
Connections
Static duct probes
15
16
17
14
17
Specifications
E-No.
A2G-05, A2G-10, A2G-15
Flat head screw 4.2 × 16
40180018
A2G-25, A2G-40, A2G-50,
A2G-55
Slotted pan head screw 3.9 × 19 ST VZN
40213072
Plastic black
40212360
For pipes ¼", insertion length 100 mm
40232956
A2G-30
A2G-60
A2G-70
Slotted pan head screw 4.8 × 50 ST VZN
Plastic black
For pipes ¼", insertion length 150 mm
A2G-05, A2G-10, A2G-15
For pipes ¼", insertion length 200 mm
Combi tube connection, insertion length 100 mm
Combi tube connection, insertion length 150 mm
A2G-30
Weather protection
A2G-05, A2G-10, A2G-15
www.air2guide.com
16
Model
Filling liquid 30 ml
Sticker red/green
15
A2G-30
Combi tube connection, insertion length 200 mm
Display fluid red 0.786
Labelling glue
kg/dm3
For air2guide built-in version
40213081
40212351
40232964
40232972
40232981
40232999
40233006
40213714
40213731
40241564
27
WIKA worldwide
Europe
North America
Austria
WIKA Messgerätevertrieb
Ursula Wiegand GmbH & Co. KG
Perfektastr. 83
1230 Vienna
Tel. +43 1 8691631
Fax: +43 1 8691634
info@wika.at
www.wika.at
Romania
WIKA Instruments Romania S.R.L.
050897 Bucuresti
Calea Rahovei Nr. 266-268
Corp 61, Etaj 1
Tel. +40 21 4048327
Fax: +40 21 4563137
m.anghel@wika.ro
www.wika.ro
Canada
WIKA Instruments Ltd.
Head Office
3103 Parsons Road
Edmonton, Alberta, T6N 1C8
Tel. +1 780 4637035
Fax: +1 780 4620017
info@wika.ca
www.wika.ca
Belarus
WIKA Belarus
Ul. Zaharova 50B, Office 3H
220088 Minsk
Tel. +375 17 2945711
Fax: +375 17 2945711
info@wika.by
www.wika.by
Russia
ZAO WIKA MERA
Wjatskaya Str. 27, Building 17
Office 205/206
127015 Moscow
Tel. +7 495-648018-0
Fax: +7 495-648018-1
info@wika.ru
www.wika.ru
Mexico
Instrumentos WIKA Mexico
S.A. de C.V.
Viena 20 Ofna 301
Col. Juarez, Del. Cuauthemoc
06600 Mexico D.F.
Tel. +52 55 50205300
Fax: +52 55 50205300
ventas@wika.com
www.wika.com.mx
Benelux
WIKA Benelux
Industrial estate De Berk
Newtonweg 12
6101 WX Echt
Tel. +31 475 535500
Fax: +31 475 535446
info@wika.nl
www.wika.nl
Bulgaria
WIKA Bulgaria EOOD
Akad.Ivan Geshov Blvd. 2E
Business Center Serdika, office 3/104
1330 Sofia
Tel. +359 2 82138-10
Fax: +359 2 82138-13
info@wika.bg
www.wika.bg
Croatia
WIKA Croatia d.o.o.
Hrastovicka 19
10250 Zagreb-Lucko
Tel. +385 1 6531-034
Fax: +385 1 6531-357
info@wika.hr
www.wika.hr
Finland
WIKA Finland Oy
Melkonkatu 24
00210 Helsinki
Tel. +358 9 682492-0
Fax: +358 9 682492-70
info@wika.fi
www.wika.fi
France
WIKA Instruments s.a.r.l.
Parc d‘Affaires des Bellevues
8 rue Rosa Luxembourg
95610 Eragny-sur-Oise
Tel. +33 1 343084-84
Fax: +33 1 343084-94
info@wika.fr
www.wika.fr
Germany
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Str. 30
63911 Klingenberg
Tel. +49 9372 132-0
Fax: +49 9372 132-406
info@wika.de
www.wika.de
Italy
WIKA Italia Srl & C. Sas
Via G. Marconi 8
20020 Arese Milano
Tel. +39 02 93861-1
Fax: +39 02 93861-74
info@wika.it
www.wika.it
Poland
WIKA Polska spółka z ograniczoną
odpowiedzialnością sp. k.
ul. Legska 29/35
87-800 Wloclawek
Tel. +48 54 230110-0
Fax: +48 54 230110-1
info@wikapolska.pl
www.wikapolska.pl
Serbia
WIKA Merna Tehnika d.o.o.
Sime Solaje 15
11060 Belgrade
Tel. +381 11 2763722
Fax: +381 11 753674
info@wika.rs
www.wika.rs
Spain
Instrumentos WIKA S.A.U.
C/Josep Carner, 11-17
08205 Sabadell Barcelona
Tel. +34 933 9386-30
Fax: +34 933 9386-66
info@wika.es
www.wika.es
Switzerland
MANOMETER AG
Industriestrasse 11
6285 Hitzkirch
Tel. +41 41 91972-72
Fax: +41 41 91972-73
info@manometer.ch
www.manometer.ch
Turkey
WIKA Instruments Istanbul
Basinc ve Sicaklik Ölcme Cihazlari
Ith. Ihr. ve Tic. Ltd. Sti.
Bayraktar Bulvari No. 17
34775 Şerifali-Yukarı Dudullu - Istanbul
Tel. +90 216 41590-66
Fax: +90 216 41590-97
info@wika.com.tr
www.wika.com.tr
Ukraine
TOV WIKA Prylad
M. Raskovoy Str. 11, A
PO 200
02660 Kyiv
Tel. +38 044 4968380
Fax: +38 044 4968380
info@wika.ua
www.wika.ua
United Kingdom
WIKA Instruments Ltd
Merstham, Redhill RH13LG
Tel. +44 1737 644-008
Fax: +44 1737 644-403
info@wika.co.uk
www.wika.co.uk
USA
WIKA Instrument, LP
1000 Wiegand Boulevard
Lawrenceville, GA 30043
Tel. +1 770 5138200
Fax: +1 770 3385118
info@wika.com
www.wika.com
WIKA Process Solutions, LP.
950 Hall Court
Deer Park, TX 77536
Tel. +1 713 47500-22
Fax: +1 713 47500-11
info@wikahouston.com
www.wika.com
Mensor Corporation
201 Barnes Drive
San Marcos, TX 78666
Tel. +1 512 3964200-15
Fax: +1 512 3961820
sales@mensor.com
www.mensor.com
South America
Argentina
WIKA Argentina S.A.
Gral. Lavalle 3568
(B1603AUH) Villa Martelli
Buenos Aires
Tel. +54 11 47301800
Fax: +54 11 47610050
info@wika.com.ar
www.wika.com.ar
Brazil
WIKA do Brasil Ind. e Com. Ltda.
Av. Ursula Wiegand, 03
CEP 18560-000 Iperó - SP
Tel. +55 15 34599700
Fax: +55 15 32661650
vendas@wika.de
www.wika.com.br
Chile
WIKA Chile S.p.A.
Av. Coronel Pereira 72
Oficina 101
Las Condes - Santiago de Chile
Tel. +56 2 365-1719
info@wika.cl
www.wika.cl
Colombia
Instrumentos WIKA Colombia S.A.S.
Dorado Plaza,
Avenida Calle 26 No. 85D – 55
Local 126 y 126 A
Bogotá – Colombia
Tel. +57 1 744 3455
info@wika.co
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30∙63911 Klingenberg∙Germany
Tel. +49 9372 132-0∙Fax +49 9372 132-406
info@wika.de∙www.wika.de
12999106 06/2013 GB
Asia
Azerbaijan
WIKA Azerbaijan LLC
Caspian Business Center
9th floor 40 J.Jabbarli str.
AZ1065 Baku
Tel. +994 12 49704-61
Fax: +994 12 49704-62
info@wika.az
Taiwan
WIKA Instrumentation Taiwan Ltd.
Min-Tsu Road, Pinjen
32451 Taoyuan
Tel. +886 3 420 6052
Fax: +886 3 490 0080
info@wika.com.tw
www.wika.com.tw
China
WIKA International Trading Shanghai
Co., Ltd.
A2615, NO.100, Zunyi Road
Changning District
Shanghai 200051
Tel. +86 21 538525-72
Fax: +86 21 538525-75
info@wika.cn
www. wika.com.cn
Thailand
WIKA Instrumentation Corporation
Thailand Co., Ltd.
850/7 Ladkrabang Road, Ladkrabang
Bangkok 10520
Tel. +66 2 32668-76
Fax: +66 2 32668-74
info@wika.co.th
www.wika.co.th
WIKA Instrumentation Suzhou Co., Ltd.
81, Ta Yuan Road, SND
Suzhou 215011
Tel. +86 512 6878 8000
Fax: +86 512 6878 0300
info@wika.cn
www. wika.com.cn
India
WIKA Instruments India Pvt. Ltd.
Village Kesnand, Wagholi
Pune - 412 207
Tel. +91 20 66293-200
Fax: +91 20 66293-325
sales@wika.co.in
www.wika.co.in
Japan
WIKA Japan K. K.
MG Shibaura Bldg. 6F
1-8-4, Shibaura, Minato-ku
Tokyo 105-0023
Tel. +81 3 5439-6673
Fax: +81 3 5439-6674
info@wika.co.jp
www.wika.co.jp
Kazakhstan
TOO WIKA Kazakhstan
Raimbekstr. 169, 3rd floor
050050 Almaty
Tel. +7 727 2330848
Fax: +7 727 2789905
info@wika.kz
www.wika.kz
Korea
WIKA Korea Ltd.
569-21 Gasan-dong, Geumcheon-gu
Seoul 153-771 Korea
Tel. +82 2 86905-05
Fax: +82 2 86905-25
info@wika.co.kr
www.wika.co.kr
Malaysia
WIKA Instrumentation M Sdn. Bhd.
No. 27 & 29 Jalan Puteri 5/20
Bandar Puteri Puchong
47100 Puchong, Selangor
Tel. +60 3 806310-80
Fax: +60 3 806310-70
info@wika.com.my
www.wika.com.my
Philippines
WIKA Instruments Philippines, Inc.
Unit 102 Skyway Twin Towers
351 Capt. Henry Javier St.
Bgy. Oranbo, Pasig City 1600
Tel. +63 2 234-1270
Fax: +63 2 695-9043
danny.reodica@wika.com
www.wika.com.ph
Singapore
WIKA Instrumentation Pte. Ltd.
13 Kian Teck Crescent
628878 Singapore
Tel. +65 6844 5506
Fax: +65 6844 5507
info@wika.com.sg
www.wika.com.sg
Africa / Middle East
Egypt
WIKA Near East Ltd.
Villa No. 6, Mohamed Fahmy
Elmohdar St. - of Eltayaran St.
1st District - Nasr City - Cairo
Tel. +20 2 240 13130
Fax: +20 2 240 13113
info@wika.com.eg
www.wika.com.eg
Namibia
WIKA Instruments Namibia Pty Ltd.
P.O. Box 31263
Pionierspark
Windhoek
Tel. +26 4 61238811
Fax: +26 4 61233403
info@wika.com.na
www.wika.com.na
South Africa
WIKA Instruments Pty. Ltd.
Gardenview
Johannesburg 2047
Tel. +27 11 62100-00
Fax: +27 11 62100-59
sales@wika.co.za
www.wika.co.za
United Arab Emirates
WIKA Middle East FZE
P.O. Box 17492
Jebel Ali, Dubai
Tel. +971 4 8839-190
Fax: +971 4 8839-198
wikame@emirates.net.ae
www.wika.ae
Australia
Australia
WIKA Australia Pty. Ltd.
Unit K, 10-16 South Street
Rydalmere, NSW 2116
Tel. +61 2 88455222
Fax: +61 2 96844767
sales@wika.com.au
www.wika.com.au
New Zealand
WIKA Instruments Limited
Unit 7 / 49 Sainsbury Road
St Lukes - Auckland 1025
Tel. +64 9 8479020
Fax: +64 9 8465964
info@wika.co.nz
www.wika.co.nz