NORTHBRIDGE Resistive(1.0pf) Loadbanks: 2kW – 3,500kW Ratings All standard Northbridge loadbanks are rated for continuous operation in ambient temperatures up to 35°C, (tropicalized versions are also available for operation at higher temperatures). Resistive (1.0pf) loadbanks can be manufactured to any size at any voltage and frequency to suit customer requirements. A standard range of loadbanks with ratings between 2kW and 3,500kW at customer specified voltage and frequency are available in standard frame sizes. Resistive loadbanks are not effected by change in frequency but must not be operated at voltage above the specified voltage. They may however be used on lower voltages but the total load available will be proportionally reduced. When operating at reduced voltages or at frequencies other than the specified frequency the cooling fans and control circuits will require the connection of a suitable external auxiliary supply. Standard resistive loadbanks with rating up to 1,600kW are available in folded steel enclosure, larger loadbanks with ratings up to 3,000kW are built in ISO type containers 100kW Transportable Loadbank Standard Frame Sizes Type Transportable Dimensions Long High Fixed Long High Both Wide Weight mm Kg Frame Max Kw A 10 550 415 550 400 475 25 B 30 825 515 825 500 500 52 C 100 750 720 845 675 875 130 D 300 825 1350 1000 1275 875 250 E 400 1275 1520 1450 1475 1025 390 F 700 1550 1520 1700 1475 1000 650 G 1200 2060 2200 2385 2100 1000 1340 H 1600 N/A N/A 3100 2152 1000 1550 I 2600 2991 2430 2991 2430 2590 5100 J 3500 6068 2430 6058 2430 2590 6400 mm mm Enclosures Folded steel and ISO container type enclosure are both available in two forms: one designed for fixed installation at permanent outdoor locations, the other transportable for moving from site to site. Both types give IP55 and have overhead lifting facilities. Resistive Elements Totally enclosed tubular stainless steel elements, switched in groups of various values by contactors provide a variable resistive load with a 1kW resolution. The elements are mounted inside an element chamber isolated from the other equipment and cooled by forced air from motor driven fans. The fans are controlled by DOL starters with thermal overloads NORTHBRIDGE DUSTRIAL SERVICES and electrical interlocking which prevents load from being applied unless the fans are running. Thermal sensors will shed all load if the temperature inside the element chamber exceeds a safe limit. Air flow sensors are fitted on units rated above 400kW to protect against loss or reduction in airflow. NORTHBRIDGE Middle East United Arab Emirates www.northbridge-me.com 200kW Fixed Loadbank Industrial Services Pte Ltd United Kingdom www.crestchic.co.uk Singapore www.northbridge-ap.com DUSTRIAL SERVICES NORTHBRIDGE Resistive(1.0pf) Loadbanks: 2kW – 3,500kW Control Systems Northbridge loadbanks can be supplied with any one of the following five standard control systems, with each system being carefully designed to meet a particular range of applications. Basic Control Provides the simplest form of control where load is required to be switched in a limited number of fixed steps to provide manual load test or dummy loading. The load steps are switched by contactors, the coils of which are controlled by simple on/off toggle switches mounted on the loadbank or are wired out to the terminals for incorporation into the customers own control system. KCS Control The most commonly used of the five types of control, this manually operated PCB mounted system is used where accurate local or remote manual control is required. Consisting of a decoder and driver cards mounted in the loadbank, the system can be supplied with any one of three types of control terminal: local, remote or hand-held. Each allows loads to be selected and applied with a 1kW switching resolution. 1,600kW Transportable in ISO Container MCS Control The MCS control system is used when automatic programmable control and instrumentation is required. The sophisticated computer control system consists of a Northbridge designed micro-processor and a choice of remote control terminals. The micro-processor inside the loadbank carries out all computing needed for calculation and control of complex loads, measurement and storage of data. Control instructions are entered via a keyboard and data is displayed on the screen of the control terminal. Baseload Control A low cost system designed to ensure that a generator never runs below a preset minimum load. Load is switched in one or two steps by contactors controlled by a PCB mounted controller monitoring the 5 amp secondary of a current transformer installed in one phase of the generator output. Load Trakker Control Like the Baseload control this system is also designed to ensure that a generator is never run below a minimum load level, however, unlike the Baseload control system it uses a microprocessor based system constantly adjusting the load in 1kW steps to maintain the preset minimum and can also be used to manually control the loadbank allowing it to be used for conventional periodic testing. 600kW Transportable Loadbank We reserve the right to supply products which may differ in detail from those described and illustrated in this publication. NORTHBRIDGE NORTHBRIDGE Middle East United Arab Emirates www.northbridge-me.com DUSTRIAL SERVICES Industrial Services Pte Ltd United Kingdom www.crestchic.co.uk Singapore www.northbridge-ap.com DUSTRIAL SERVICES