domino 1050, domino 1050 rc

advertisement
FITTING AND OPERATING INSTRUCTIONS
ENGLISH
DOMINO 1050, DOMINO 1050 RC
SAFETY INFORMATION
CLOSING THE RADAR SENSOR UNIT
The unit is only to be operated
with voltages that comply with the
Safety Extra­Low Voltage (SELV)
requirements in safety standards based on IEC
60950. This unit is only to be installed and
maintained by trained, qualified personnel.
Insert the cover from the top and press until it clicks in place
1
2
3
FITTING
OPENTHE RADAR MOTION SENSOR
click
Never open the sensor from the top!
SETTINGS
OPERATING ELEMENTS
1 Pluggable Antenna
2 Potentiometer
3 Terminal
4 Programming button
2
5 LED
Remove the sticker after instaflflation!
DRILLING
1
4
Stick the drilling template in place and drill
according to the instructions
5
3
FASTENING AND CONNECTING-UP
SIzE OF THE DETECTION AREA / SENSITIvITY
Power
12 – 36 V DC / 12 – 28 V AC
1
1 Power supply AC/DC
2 Power supply AC/DC
3 Relay contact 1
4 Relay contact 2
white
black
red
green
Draw the cable through the opening provided
and connect it to the terminal
2
A wide or a narrow detection area can be realized with the
plug­ and turnable antenna. See below examples.
Fitting height 2.2 m / Detection area angle 30° / Sensitivity max.
wide detection area
narrow detection area
3
Fasten the base plate with the screws contained in the housing,
to remove and insert the electronics, observe the instructions in point 2.3
OTHER INSTALLATION OPTIONS
ca. 4.5 m
Optional accessory out of the accessory range.
Ceiling­mounting with mounting bracket or wall
fastening with weather­cap set.
m
2. Adjust the radar sensor unit / Check
the setting by pacing out the distance
Withdraw the antenne carefully with two fingers, turn
it, plug it into the provided opening and press it soft.
The adhesive tape on the back side of the antenna is
mulit­adaptive.
Static sensitive devices.
10 Sek./sec.
ca. 2.0 m
To turn the antenna do not use any metallic tools!
3
1
2
.5
.4
ca
max. installation height 4 m
SETTING UP THE RADAR SENSOR UNIT
1. Switch on the unit and wait 10 seconds
(LED flashes red/green)
.0
.2
ca
m
POSITION OF THE DETECTION AREA
To make an adjustment, take hold of the printed
circuit board by the edge, pull it forward, and
then place it in the desired position.
The position can be adjusted in 5° steps from
0° to 40°. The factory setting is 30°, notches
can be broken out.
0°
1
2
0°
5°
40°
2
The printed circuit board can also be inserted at a slant angle.
40°
Turn maximum 3 steps to the right or to the left!
ADJUST OF THE DETECTION AREA / SENSITIvITY
Turn the potentiometer to change the size
(sensitivity) of the detection area.
min.
max.
min.
50%
max.
RECTIFICATION
Door sees itself
reduce sensitivity, position radar sensor unit further forwards
LED fails to illuminate
no power supply, unit defective
Sensor responds on littel influences
Increase the immunity settings in point 2.7
Sensor responds to slow or to fast
Change the response settings in point 2.7
Door opens without any reason
Increase the immunity settings in point 2.7
Potentiometer without function
Address has been set, the IR­mode is activated (for RC­Version only)
LED STATUS DISPLAY
green
red
green flashing
red flashing
green/red flashing
LED
unit ready for operation
detection
command received
error
initialisation (for 10 seconds after switching on)
THE PROGRAMMING MODE
With the programming button and the potentiometer can be adjusted the relay contact,
delay time, response, immunity and addressing.
Sign description
>2s
press the programming button longer than 2 s
choose potentiometer position
press the programming button less than 1 s
Potentiometer setting range
1x
flash code green LED (repetitive every 3 s)
<1s
1x
flash code red LED (repetitive every 3 s)
Programming
programming steps
2
1
Change the relay contact
Set the output hold time
3
>2s
>2s
1x
>2s
>2s
2x
>2s
>2s
3x
Response
Fast response, the sensor swit­
ches earlier, it is more sensitive.
Slow response, the sensor swit­
ches later, it is less sensitive.
>2s
Reset
>2s
4x
Immunity
The immunity allows to mini­
mize different, external inter­
ferences. e.g. rain, vibrations,
reflections.
Addressing
This function is only applicable
with the RC­versions.
4
>2s
> 10 s
5x
>2s
1x
N.O.
2x
N.C.
0x
1x
2x
3x
4x
5x
6x
7x
8x
9x
10 x
<1s
aus / off
0.2 s
0.5 s
1.0 s
1.5 s
2.0 s
2.5 s
3.0 s
4.0 s
5.0 s
10.0 s
<1s
1x
2x
3x
4x
0x
1x
2x
3x
4x
5x
6x
7x
8x
9x
10 x
0x
1x
2x
3x
4x
5x
6x
7x
8x
5
<1s
aus / off
normal / normal
min.
<1s
max.
IR­Modus aus / IR­mode off
Adresse / address 1
Adresse / address 2
Adresse / address 3
Adresse / address 4
Adresse / address 5
Adresse / address 6
Adresse / address 7
Adresse / address 8
Press the programming button until the LED starts green/red flashing during approximately 10 s.
<1s
DISTURBING INFLUENCES – INSTALLATION RECOMMENDATIONS
The radar sensor unit must be installed firmly.
It should not vibrate.
The radar sensor unit must not be installed behind a panel
or other cover.
No moving objects (e.g. fans, plants, trees, flags, etc.)
are permitted in the detection area of the radar sensor unit.
In this case the installation of a
weather-cap out of the accessory
range is recommended.
The radar sensor unit must not be fitted close to fluorescent
lamps.
The radar sensor unit should be installed in a position
where it is protected from rain.
SCOPE OF DELI vERY
OPTIONAL ACCESSORIES
­ DOMINO 1050
­ Connecting cable
­ Fitting screws
­
Drilling template in the form of a peel­off sticker
­ Fitting and operating instruction
­ Ceiling­mounting bracket
­ Weather­cap set
(ceiling mounting bracket included)
­
Domi­LINK (remote control for RC­versions)
TECHNICAL DATA
Supply voltage
12 ­ 36 V DC / 12 ­ 28 V AC
max. switching current
1A
Current consumption approx.
ca. 50 mA @ 24 V DC, 20 °C
Hold time
0.2 s ­ 10 s / factory setting 1 s
Power consumption
<1W
Protection class
IP54
Temperature range
­20 °C to +60 °C / ­4 °F bis 140 °F
Housing material
ABS
Atmospheric humidity
0 to 90 % RH, non­condensing
Dimensions
123 mm (W) x 65 mm (H) x 57 mm (D)
Microwave module
K band 24.05 GHz ­ 24.25 GHz
Weight
120 g
Transmitting power
< 20 dBm
max. installation height
4m
Relay output potential free
NO or NC
Electromagnetic compatibility
CE in accordance with EMC directive 89/336/EEC
Rating
0.5 A AC / 1 A DC
min. detection speed
0.1 m/s
max. switching power
24 W / 60 VA
Approval
CETECOM, test report no.: 2­3693­01­01/04
max. switching voltage
48 V AC / 48 V DC
This unit complies with the requirements of the European R&TTE directive.
The declaration of conformity can be called up on the following website: www.4tec­ag.ch
Download