IP 64 NPN NPN DC 12 bis to 30V 30V pulsed gepulst 10 kHz 10 kHz ACCESSORIES FOR LIGHT BARRIERS Pulsating-light amplifier WLV3 The pulsating-light amplifier pulses the transmitter diode of the light barrier. The signal detected by the receiver element of the light barrier is amplified and synchronously evaluated. All sensors of GLS series can be operated in combination with the pulsating-light amplifier WLV3. The output of the pulsating-light amplifier provides a signal that gives information about the switching state of the light barrier (unfree/ free). Features: Technical data: w Pulsating-light operation increases the insensitivity of the connected light barrier to outside light and dirtying (synchronous evaluation). w The sensitivity can be set by means of a potentiometer w LED switching output indicators (red: unfree / green: free) w Switching mode: dark-switching / bright-switching w NPN or PNP output w Yellow LED as indicator for dirtying 12V-30V Operating voltage: 10 % Residual ripple: 10 KHz Clock frequency: 1 KHz Operation frequency: 200 mA Max. current input: (with 55mA output current: bright switching, NPN or PNP Output: -20°C to +60°C Operating temperature: IP 64 Type of protection: aluminium, anodized in blue Housing: Design: Aufbau: 4 1 2 6 3 5 1 270°-Buchse, 270° socket, 5-pin5-polig (connection: light barrier) 2 Potentiometer zur Potentiometer for sensitivity setting 3 Duo-LED "switching state" Duo-LED "Schaltzustand" red: unfree / green: free rot: bedämpft (Anschluß:Lichtschranke) Empfindlichkeitseinstellung 4 270° plug (5-pin) (5-polig) 270°-Stecker 5 LED " Verschmutzung " LED "dirtying" gelb:"dirtying" verschmutzt yellow: 6 Facility for mounting Befestigungsmöglichkeiten grün: unbedämpft Dimensions: Sensor Instruments GmbH · Schlinding 11 · D-94169 Thurmansbang · Tel. 08544/9719-0· Fax 08544/971913 Interface: 270° socket (5-pin) Output 270° plug (5-pin) n.c. Transmitter anode n.c. n.c. 3 +24V/DC 3 2 4 4 2 1 5 5 1 +24V/DC Ground Connection monitor Receiver (collector) Transmitter cathode Receiver (emitter) Sensitivity setting: Potentiometer Comment Setting Turn potentiometer 3 turns in clockwise direction (+direction). Minimum detectable segment width: 0.3 mm (depends on the fork light barrier or blow-air fork light barrier used). Turn potentiometer 3 turn in clockwise direction (+direction). Then turn it 1.5 turns in anticlockwise direction (-direction). WLV is more insensitive to dirtying: minimum detectable segment width: 0.5 mm (depends on the fork light barrier or blow-air fork light barrier used). Turn potentiometer 3 turns in anticlockwise direction (-direction). WLV is extremely insensitive to dirtying: minimum detectable segment width: 0.7 mm (depends on the fork light barrier or blow-air fork light barrier used) Highest sensitivity Medium sensitivity Lowest sensitivity Explanation of terms: +24V DC Load Bright- and dark-switching npn free S E S E S +24V GND interrupted free interrupted E S E +24V DC pnp Output: high (+24V) Output: low (0V) Bright-switching Output: low Output: high (+24V) (0V) Dark-switching PNP output: In case of the PNP output the load is connected to GND at the output line. If an event occurs, the PNP output transistor switches the output through to plus, which results in a current flow through the load resistor. This type of control logic is called minus-switching. Product group: Load +24V GND NPN output: The electronic unit has a transistor output; the load lies between the plus pole of the supply voltage and the output line, which is switched through to GND by the output transistor (NPN transistor), if an event occurs. This output is also called plus-switching. Fork light barrier GLS-VIS Fork light barrier GLS Fork light barrier with air cleaning GLS-BL Split light barrier LS-04 5-pin SI-KAB1 SI-KAB1 5-pin Split light barrier with diode connector (5-pin) GLS-D WLV 5-pin Connecting cable 5-pin SI-KAB2 SI-KAB2 Split light barrier LS-05 Split light barrier LS-08 5-pin WLV3-e Pulsating-light amplifier Connecting cable