Level Switches

advertisement
SEE MORE AT SORInc.com
Request Quote
Level Switches
SOR® mechanical level switches
are rugged, industrial products specifically
designed for versatility of application. This catalog
contains application and ordering data for float and
displacer-operated level switches. Switches are
available with flanged or sealed chambers or
as insertion models.
200 Series
Options available for each type of switch
include: switch type and number, housing type,
chamber material, process connections,
accessories, and more. Units may be
customized to suit customers’ needs.
Inside this catalog you will find solutions to
your level sensing puzzles. SOR mechanical
level switches have many configurations
available. If you don’t see what you need, we
will engineer a solution for your application.
100 Series
Features and Benefits
700 Series
• Five-year warranty
• Worldwide listings and certifications
• ASME Section IX and AWS qualified
welding system
• Quick worldwide delivery
• Designed to ANSI/ASME B31.1 and
B31.3 guidelines
• Only ASTM grade materials with
certified mill test reports used
•Safety Certified to IEC 61508 (SIL)
SOR products are certified to IEC
• Hermetically sealed switching
61508 for non-redundant use in
mechanisms available
SIL1 and SIL2 Safety Instrumented
• Stainless steel switching mechanisms
Systems for most models. For more
• High-temperature capability
details or values applicable to a
• Wide variety of explosion-proof housings specific product, see the Safety
Integrity Level Quick Guide
• Versatile switching mechanisms which
retro-fit into other manufacturers’ units (Form 1528).
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
1/60
Level Switches
700 Series
Top
Mounted
Displacer
200 Series
Sealed Chamber Float
100 Series
Flanged Chamber Float
300
Top
Mounted
Float
208 Steam Trap Float
400 Series
Side Mounted Float
2/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Section
Table of Contents
Page
Principles...........................................................................................................4
Features and Benefits...................................................................................6
How to Order....................................................................................................8
Float Switches
100 Series Flanged External Cage................................................... 9
200 Series Sealed External Cage................................................... 14
108/208 Series Steam Condensate External Cage.................. 18
300 Series Top Insertion Mount...................................................... 20
400 Series Side Insertion Mount.................................................... 23
Displacer Switches
Models 741-743, and 802 Flanged External Cage..................... 26
Models 740 and 804 Sealed External Cage................................ 30
700 Series Single-Stage Top Insertion Mount............................. 33
730 Series Dual-Stage Top Insertion Mount................................ 36
750 Series Triple-Stage Top Insertion Mount.............................. 40
Switching Mechanisms.............................................................................. 44
Switch Ratings ............................................................................................. 47
Housings......................................................................................................... 48
Accessories
Compatibility Chart............................................................................. 49
Test Certificates................................................................................... 50
High Temperature Selection............................................................. 51
CY and CZ Option Inspection Requirements.............................. 55
MC and TC Options........................................................................... 56
ASTM Material Designations............................................................ 57
Reference Charts
Specific Gravity of Water.................................................................. 58
Conversions......................................................................................... 59
Weights................................................................................................. 60
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
3/60
Level Switches
Principles
Float-Operated Level Switches
Model Series 100, 200 and 300
The float rides on the process liquid surface,
precisely tracking liquid surface motion.
Switching Element
Common
Rising liquid level lifts the float, sliding the attraction
sleeve up inside the enclosing tube and into the
magnetic field to actuate the electrical or
pneumatic switch (signaling liquid presence).
Normally Open
Normally Closed
Pivot
Bias Spring
Subsequently, falling liquid level lowers the float,
drawing the attraction sleeve out of the magnetic
field to deactuate the electrical or pneumatic switch
(signaling liquid absence). Float-type level switches
are generally able to handle high-temperature
applications, and sometimes prove useful for close
interface detection.
Floats can operate up to three switching elements.
Independent switching levels may be obtained with
tandem floats. Consult the factory for special floatswitching arrangements.
Magnet
Attraction Sleeve
Enclosing Tube
Float
Level
Differential
Actuated
Deactuated
Float-Operated Level Switches
Model Series 108/208 and 400
The float rides on the process liquid surface, precisely tracking liquid surface motion.
Rising liquid level lifts the float via a pivot mechanism, sliding the attraction sleeve down inside
the enclosing tube and out of the magnetic field to deactuate the electrical or pneumatic switch
(signaling liquid presence).
Subsequently, falling liquid level lowers the float, drawing the attraction sleeve into the magnetic field
to actuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are
generally able to handle high-temperature applications.
Switching
Element
Actuated
Switching
Element
Deactuated
C Common
NC Normally Closed
Magnetic
Field
Engaged
NO Normally Open
Attraction
Sleeve Up
Bias Spring
Enclosing Tube
C Common
NC Normally Closed
Magnetic
Field
Disengaged
NO Normally Open
Bias Spring
Enclosing Tube
Attraction
Sleeve
Down
Counterweight
Level
Differential
Actuated
4/60
Registered Quality System to ISO 9001
Deactuated
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Principles
Displacer-Operated Level Switches
Model Series 700, 730, 740, 750 and 800
Displacer controls offer alternative features to
the float-operated control. The sensor is a
weight (displacer), heavier than the liquid, that
is suspended by a spring. When liquid contacts
the displacer, a buoyancy force is produced,
which causes the effective weight of the
displacer to change. This causes the spring to
retract slightly to a new equilibrium position.
When the spring retracts, the attraction sleeve
also moves upward into the field of the external
magnet, thus overcoming the force of the bias
spring and actuating the switching element.
This principle provides for narrow or wide
switching differential, and allows switching point
alteration by moving the displacer(s) up or down
the suspension cables.
Displacers may be arranged in combinations
of narrow and wide differential to operate up
to three switching stages. Displacer controls
operate under higher pressure conditions than
float-operated switches.
Form 912 (01.15) ©SOR Inc.
SORInc.com
Switching Element
Common
Normally Open
Normally Closed
Pivot
Bias Spring
Magnet
Attraction Sleeve
Enclosing Tube
Extension Spring
Suspension Rod / Cable
Displacer
Level
Differential
Actuated
Deactuated
| 913-888-2630 | Registered Quality System to ISO 9001
5/60
Features and Benefits
Level Switches
Features and Benefits
General






Rugged carbon steel or stainless steel construction
Five-year manufacturer’s warranty
Quick, worldwide delivery
All ASTM materials (see page 56)
Quality management system is registered to ISO-9001:2008
Safety Certified to IEC 61508 (SIL)
Standard Chamber Materials
All SOR level switch chambers are constructed using ASTM grade materials
with full material certification. Mill Test Reports are kept on file for all raw materials. Copies are available upon request at the time of order placement.

Carbon Steel Construction
Chamber Center Section
Flanges/Weld Fittings
Weld Cap
Studs/Nuts
A106 Grade B
A105
A234-WPB
A193-B7/A194-2H
Stainless Steel Construction
Chamber Center Section
Flanges/Weld Fittings
Weld Cap
Studs/Nuts
A312-TP316/316L
A182-316/316L
A403-316/316L
A193-B7/A194-2H
Gaskets



All standard models are provided with a Nitrile binder composite gasket that is
selected for its resistance to hydrocarbons and steam.
For high-temperature, high-pressure or NACE-constructed units, a spiral-wound
gasket is used with 316SS wound-around Grafoil.
Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber
head flange.
Internal Trim
All sensing elements (floats and displacers) are constructed of either
316/316LSS or porcelain as a minimum.
 Attraction sleeves are available in 400SS as a standard, with 316/316LSS or other exotic metals as an option.
 All other wetted internal parts are 316SS or better. Displacer springs are made
of Inconel 600.

6/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Features and Benefits
Level Switches
Features and Benefits
Switching Mechanisms
SOR switching mechanisms are designed for use in punishing industrial conditions.
 All stainless steel construction - no aluminum or brass.
 Temperature ratings available from -65°F (–54°C) to 1000°F (538°C) on
dry, non–condensing services.
 Condensing service (steam) temperature ratings available up to 800°F (427°C), and up to 1200°F (649°C) with protection (see page 52).
 Available switching mechanisms include hermetically sealed, standard open
contacts, or pneumatic contacts.
 Agency listings are available on most switch mechanisms: UL, CSA, ATEX or IECEx.
Switch Housings
All SOR switch housings are made from rugged castings. Materials are
copper-free aluminum or cast iron. A wide range of explosion-proof ratings and agency
listings are available.
Quality Assurance
SOR maintains a high level of quality throughout our corporation. Many quality
assurance features are built into our products.
 ISO 9001 certified engineering design and production system (certified
since 1993).
 Level-welded chambers designed to the guidelines of ASME B31.1 and
B31.3 (inspection certificate available – see page 54).
 All welders and weld procedures are qualified and maintained to
ASME Section IX.
 All ASTM grade materials used - Certified Mill Test Reports required on
all raw materials.
Safety Certified to IEC 61508 (SIL)
SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2
Safety Instrumented Systems for most models. For more details or values applicable
to a specific product, see the Safety Integrity Level Quick Guide (Form 1528).

Product Support
SOR has a full-time engineering staff dedicated to solving your mechanical level switch
problems.

Engineers and technicians are knowledgeable about sales and production techniques, and are dedicated to providing the best solution to our customers
at the best price.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
7/60
Level Switches
How to Order
Model Number System
101 A-A1C-B-A1-N4-CRTT
Model Series
Chamber
Material
Internal
Trim
Material
Process Connection
Switch
Mechanism
Housing
Accessories
The level switch model number is divided into seven sections that individually specify the
components of an SOR level switch. This diagram illustrates the model number arrangement.
Select the component designators from the appropriate pages of this brochure. Standard
components and ratings are highlighted throughout the brochure for ease of use.
Each section includes a valid model number at the top of each listing of component designators.
The position of the designator listed below it will be shown in color for reference.
How to Order
Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers,
i.e. each component must have a designator.
Step 1: Select Model Series based on maximum working pressure and minimum
specific gravity.
Step 2: Select Chamber Material.
Step 3: Select Process Connection.
Step 4: Select Trim Material.
Step 5: Select Switch Mechanism & Housing. (Pages 44 through 48).
Step 6: Select Accessories as required for service. (Page 49).
Page Numbers for Selected Steps
741-743,
802
Series
740 and
804
Series
23
26
30
33
36
40
20
23
26
30
33
36
40
21
24
27
31
34
37
41
Step
100
Series
200
Series
108/208
Series
300
400
Series Series
1
9
14
18
20
2
10
15
18
3
10
15
18
700
730
Series Series
750
Series
4
10
15
18
21
24
27
31
34
37
41
5
44-48
44-48
44-48
44-48
44-48
44-48
44-48
44-48
44-48
44-48
6
49
49
49
49
49
49
49
49
49
49
Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
8/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
100 Series
Step 1: Model Series
101 A-A1C-B-A1-N4-CRTT
The 100 Series mechanical liquid level switch is float operated with a flanged, serviceable external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 through 50 for
switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.
Pressure at Listed Temperature in psid (bar)*
Model
Series
Chamber
Material
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
101
A106B
316SS
285
275
(19.7)
(18.9)
260
235
(17.9)
(16.2)
230
215
(15.9)
(14.8)
215
205
(14.8)
(14.1)
200
195
(13.8)
(13.4)
185
182
(12.8)
(12.6)
102
A106B
316SS
500
500
(34.5)
(34.5)
500
500
(34.5)
(34.5)
500
500
(34.5)
(34.5)
486
486
(33.5)
(33.5)
473
473
(32.6)
(32.6)
460
460
(31.7)
(31.7)
103
A106B
316SS
740
720
(51.0)
(49.7)
675
620
(46.6)
(42.8)
655
560
(45.2)
(38.6)
645
537
(44.5)
(37.0)
635
515
(43.8)
(35.5)
622
497
(42.9)
(34.3)
104
A106B
316SS
990
1000
(68.2)
(69.0)
900
1000
(62.0)
(69.0)
875
1000
(60.3)
(69.0)
860
973
(59.2)
(67.1)
845
946
(58.2)
(65.2)
822
920
(56.6)
(63.4)
109
A106B
316SS
285
275
(19.7)
(18.9)
260
235
(17.9)
(16.2)
230
215
(15.9)
(14.8)
215
205
(14.8)
(14.1)
200
195
(13.8)
(13.4)
185
182
(12.8)
(12.6)
121
A106B
316SS
285
275
(19.7)
(18.9)
260
235
(17.9)
(16.2)
230
215
(15.9)
(14.8)
215
205
(14.8)
(14.1)
200
195
(13.8)
(13.4)
185
182
(12.8)
(12.6)
122
A106B
316SS
350
350
(24.1)
(24.1)
350
350
(24.1)
(24.1)
350
350
(24.1)
(24.1)
340
340
(23.4)
(23.4)
331
331
(22.8)
(22.8)
322
322
(22.2)
(22.2)
123
A106B
316SS
740
720
(51.0)
(49.7)
675
620
(46.6)
(42.8)
655
560
(45.2)
(38.6)
645
537
(44.5)
(37.0)
635
515
(43.8)
(35.5)
622
497
(42.9)
(34.3)
124
A106B
316SS
1250
1250
(86.2)
(86.2)
1250
1250
(86.2)
(86.2)
1250
1120
(86.2)
(77.2)
1216
1075
(83.9)
(74.1)
1182
1030
(81.5)
(71.0)
1150
992
(79.3)
(68.2)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
Model
Series
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Standard
316SS / 400SS
“B” Trim
w/ ET or FE Option
All 316SS
“C” Trim
316SS / 400SS
“B” Trim
All 316SS
“C” Trim
101
102
103
0.52
0.62
0.51
(0.64)
(0.73)
(0.57)
0.56
0.66
0.53
(0.67)
(0.77)
(0.59)
0.56
0.65
0.53
(0.67)
(0.76)
(0.59)
0.60
0.69
0.55
(0.71)
(0.80)
(0.61)
104
109
121
0.62
0.38
0.66
(0.68)
(0.41)
(0.87)
0.64
0.39
0.73
(0.70)
(0.42)
(0.94)
0.64
0.39
0.72
(0.70)
(0.42)
(0.93)
0.66
0.40
0.79
(0.72)
(0.43)
(1.01)
122
123
124
0.66
0.93
0.94
(0.87)
-
0.73
0.98
0.99
(0.94)
-
0.72
0.99
1.00
(0.94)
-
0.79
1.04
1.05
(1.01)
-
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
9/60
100 Series
Step 2: Chamber Material
101 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on page 9
is based on the material selected here. Consult the factory for alternative materials.
Designator
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
101 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
1”
1-1/2”
2”
Flange
Style
NPT
Thread
Socket
Weld
150#
300#
600#
VH
A1A
A1B
A1C
A1D
A1E
VV
-
-
B1C
B1D
B1E
VVD
C1A
C1B
C1C
C1D
C1E
VVT
-
-
D1C
D1D
D1E
VH
A5A
A5B
A5C
A5D
A5E
VV
-
-
B5C
B5D
B5E
VVD
C5A
C5B
C5C
C5D
C5E
VVT
-
-
D5C
D5D
D5E
VH
A2A*
A2B*
A2C
A2D
A2E
VV
-
-
B2C
B2D
B2E
VVD
C2A*
C2B*
C2C
C2D
C2E
VVT
-
-
D2C
D2D
D2E
VH
(Vertical/Horizontal)
VV
(Vertical/Vertical)
VVD
(Vertical/Vertical/
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
*Not available on Models 121 and 122.
Step 4: Trim Material
Select the internal trim material from the chart below.
Consult the factory for pressure ratings on Monel trim.
10/60
101 A-A1C-B-A1-N4-CRTT
Designator
Float Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
100 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.
Model 101
Model 102
Specific
Gravity
“B”
“C”
Specific
Gravity
“B”
“C”
.52
3-1/4”
4-7/16”
.62
2-3/4”
3-13/16”
1.0
5-1/4”
5-15/16”
1.0
4-7/16”
5-1/8”
Model 104
Model 103
Specific
Gravity
“B”
“C”
Specific
Gravity
“B”
“C”
.51
3-1/4”
3-7/8”
.62
3-3/8”
3-15/16”
1.0
4-13/16”
5-3/16”
1.0
4-5/8”
5”
Model 109
Model 121
Specific
Gravity
“B”
“C”
Specific
Gravity
“B”
“C”
.38
4-3/4”
5-15/16”
.66
2-11/16”
4-1/8”
1.0
7-1/4”
7-9/16”
1.0
3-13/16”
4-13/16”
Model 122
Model 123
Specific
Gravity
“B”
“C”
Specific
Gravity
.66
2-1/2”
3-15/16”
1.0
3-5/8”
4-5/8”
“B”
“C”
.93
2-7/8”
3-13/16”
1.0
3-3/16”
4-1/16”
Model 124
Specific
Gravity
“B”
“C”
.94
2-7/8”
3-13/16”
1.0
3-1/8”
4”
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
11/60
100 Series
Chamber Dimensions
DRAWING NU
Dimensions listed are for reference only and are expressed
as millimeters over inches. (Linear = mm/in.)
MODEL #
0390019
They are subject to change without notice. Contact
SOR
for
PURCHASE ORDER # certified drawings of particular models or if
MODEL #
SALES ORDER #
special
dimensions
are
required.
PURCHASE ORDER #
LINE ITEM #
SALES ORDER
DRAWING NUMBER
146.1
OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
101.6
4.00
180.9
7.12
101.6
4.00
* MINIMUM
*228.6
9.00
W
*228.6
9.00
W
L
L
W
180.9
7.12
14
5.7
REQUIRED TO
* MINIMUM
THIS DRAWING WAS CREATED USIN
THE VERTICAL_MOUNT_ASSY AND
FILE 0390019.txt LOCATED ON THE
K:\$Engineering Services\Concept tex
THEN THE DRAWING WAS CHANGE
DRAFT ENTITIES.
W
14
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
ISO-9001
CHECKED BY
PRODUCT CER
ALL DIMEN
UNLESS OT
J REHM
LIN
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
D
H
M SMITH
G
ENGINEER APPROVAL
J FIFE
DATE
THIS DRAW
NO USE WHA
HEREON, NOR
MADE WITHOU
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
E
1" SW
DIMONLY)
DWG 100 SERIES SERVICEABLE
(VVT
EXTERNAL CHAMBER VH STYLE
F
DRAWING NUMBER
TITLE
DIM DWG 100 S
EXTERNAL CHAM
TITLE
F
EO NUMBER: 5090
SCALE: DRAWING SCALE
0390019
SHEET
Drawing 0390021
Drawing 0390019
Model Name: MODEL NAME.DRAFT/3/0+
DO NOT SCALE PRINT
MODEL #
Model Name: MODEL NAME.DRAFT/3/1+
EO NUMBER: 5
REV
SCALE: DRAWIN
3
1 OF 1
DRAWING
DO NOT NUMBE
SCALE
DWG SIZE
A
SALES ORDER #
Reset Form
PURCHASE ORDER #
180.9
7.12
Housing**
101.6
4.00
W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
Pneumatic
P1
(3) 1/4” NPT
ATEX
Flame Proof/IS
T6
S3 w/CL
IECEx
Flame Proof
S3
S8
W
146.1
5.75
REQUIRED TO RE
* MINIMUM
*228.6
9.00
L
W
14685
M20 x 1.5***
ISO-9001
355.6
14.00
PRODUCT CERTIF
ALL DIMENSIO
UNLESS OTHE
LINEA
*Minimum 5-3/4’’ (146 mm) overhead
clearance required to remove housing cover.
**See Housing section (page 48).
***M20 adapters are brass. Contact the factory
for alternate materials.
THIS DRAWIN
NO USE WHATSO
HEREON, NOR RE
MADE WITHOUT T
I
TITLE
DRAIN CONN
1"NPT OR SW
DIM DWG 100 SER
EXTERNAL CHAMB
E
EO NUMBER: 5090
F
SCALE: DRAWING
DO NOT SCALE PRINT
Note: All process flange nipples are 1” standard.
12/60
Registered Quality System to ISO 9001
Model Name: MODEL NAME.DRAFT/3/0+
Drawing 0390010
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
100 Series
Chamber Dimensions
1” Connection
Model
101
102
103
104
109
121
122
123
124
D1, 2
E1, 2
F4
H4
G
inch
mm
inch
mm
inch
mm inch
mm
10-1/2
267
3-3/4
95
6-1/2
165
356
122
14
I2
inch mm
14
356
L2
inch
mm
3-3/4
95
10-1/4
260
4-13/16
7-7/16
189
14
356
14
356
4-9/16
116
12-5/8
321
5-13/16 148 8-7/16
214
16
406
16
406
7-1/2
191
9
229
3-1/4
83
6
152
14
356
14
356
3-3/4
95
10-1/2
267
3-3/4
95
6-1/2
165
14
356
14
356
3-3/4
95
inch
mm
16-5/8
422
17-5/16
440
18
457
19-3/4
502
17-13/16
452
16-3/8
416
16-15/16
430
17-5/16
440
18-3/4
476
1-1/2” Connection
Model
101
102
103
104
109
121
122
123
124
D1, 2
E1, 2
F4
H4
G
inch
mm
inch
mm
inch
mm
10-1/2
267
4
102
6-1/2
165
I2
inch mm inch mm
14
356
14
356
L2
inch
mm
3-3/4
95
116
inch
mm
16-5/8
422
17-5/16
440
18
457
19-3/4
502
10-1/4
260
5-1/16
129
7-7/16
189
14
356
14
356
4-9/16
13-1/16
332
6-1/16
154 8-7/16
214
16
406
16
406
7-1/2
191 17-13/16 452
9
229
3-1/2
89
6
152
14
356
14
356
3-3/4
95
10-1/2
267
4
102
6-1/2
165
14
356
14
356
3-3/4
95
16-3/8
416
16-15/16 430
17-5/16
440
18-3/4
476
2” Connection
Model
101
102
103
104
109
121
122
123
124
D1, 2
E1, 2
F4
H4
G
inch
mm
inch
mm
inch
mm
10-1/2
267
4-5/16
110
6-1/2
165
I2, 3
inch mm inch mm
14
356
14
356
L2, 3
inch
mm
4-3/4
121
inch
mm
17-5/8
448
18-5/16
467
19
483
20-3/4
527
10-1/4
260
5-3/8
137
7-7/16
189
14
356
14
356
4-9/16
116
13-3/8
340
6-3/8
162 8-7/16
214
16
406
16
406
8-1/2
216 18-13/16 478
-
-
-
-
6
152
14
356
14
356
3-3/45
955
10-1/2
267
4-5/16
110
6-1/2
165
14
356
14
356
4-3/4
121
16-3/85
4165
16-15/165 4305
18-5/16
465
19-3/4
502
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
13/60
200 Series
Step 1: Model Series
201 A-A1C-B-A1-N4-CRTT
The 200 Series mechanical level switch is float operated with a sealed, tamper-proof external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Model
Pressure at Listed Temperature in psig (bar)*
Chamber
Series
Material Working
Maximum
100°F (38°C) Pressure
200°F (93°C) 300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
See pageA106B
53 for pressure ratings at higher temperatures.
201
316SS
225
(15.5)
225
(15.5)
225
(15.5)
219
(15.1)
213
(14.7)
207
(14.3)
202
A106B
316SS
300
(20.7)
300
(20.7)
300
(20.7)
292
(20.1)
284
(19.5)
276
(19.0)
203
A106B
316SS
500
(34.5)
500
(34.5)
500
(34.5)
486
(33.5)
473
(32.6)
460
(31.7)
204
A106B
316SS
1250
(86.2)
1250
(86.2)
1250
1187
(86.2)
(81.9)
1216
1139
(83.9)
(78.6)
1182
1091
(81.5)
(75.2)
1150
1052
(79.3)
(72.6)
205
A106B
316SS
750
(51.7)
750
(51.7)
750
(51.7)
729
(50.3)
709
(48.9)
690
(47.6)
206
A106B
316SS
1000
(68.9)
1000
(68.9)
1000
945
(68.9)
(65.2)
973
907
(67.1)
(62.6)
946
869
(65.2)
(59.9)
920
838
(63.4)
(57.8
207
A106B
316SS
1000
(68.9)
1000
(68.9)
1000
945
(68.9)
(65.2)
973
907
(67.1)
(62.6)
946
869
(65.2)
(59.9)
920
838
(63.4)
(57.8
209
A106B
316SS
450
(31.0)
450
(31.0)
450
(31.0)
438
(30.2)
426
(29.4)
414
(28.6)
221
A106B
316SS
350
(24.1)
350
(24.1)
350
(24.1)
340
(23.4)
331
(22.8)
322
(22.2)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
For Monel Trim please consult factory.
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model Series
Standard
316SS / 400SS “B”
Trim
14/60
w/ ET or FE Option
All 316SS
“C” Trim
316SS / 400SS “B”
Trim
All 316SS
“C” Trim
201
202
203
0.38
0.52
0.61
(0.44)
(0.63)
(0.72)
0.40
0.55
0.65
(0.46)
(0.67)
(0.76)
0.40
0.55
0.64
(0.44)
(0.66)
(0.75)
0.42
0.59
0.68
(0.48)
(0.70)
(0.79)
204
205
206
0.91
0.50
0.65
(0.56)
(0.75)
0.96
0.52
0.68
(0.58)
(0.79)
0.98
0.52
0.68
(0.58)
(0.79)
1.03
0.54
0.71
(0.60)
(0.82)
207
209
221
0.61
0.38
0.64
(0.67)
(0.41)
(0.86)
0.63
0.39
0.72
(0.69)
(0.42)
(0.93)
0.63
0.39
0.71
(0.69)
(0.42)
(0.92)
0.65
0.40
0.78
(0.71)
(0.43)
(0.99)
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
200 Series
Step 2: Chamber Material
201 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on
this page is based on the material selected here. Consult the factory for alternative materials.
Designator
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
201 A-A1C-B-A1-N4-CRTT
Select a process connection, size, style and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
1”
1-1/2”
2”
Flange
Style
NPT
Thread
Socket
Weld
150#
300#
600#
VH
A1A
A1B
A1C
A1D
A1E
VV
-
-
B1C
B1D
B1E
VVD
C1A
C1B
C1C
C1D
C1E
VVT
-
-
D1C
D1D
D1E
VH
A5A
A5B
A5C
A5D
A5E
VV
-
-
B5C
B5D
B5E
VVD
C5A
C5B
C5C
C5D
C5E
VVT
-
-
D5C
D5D
D5E
VH
A2A*
A2B*
A2C
A2D
A2E
VV
-
-
B2C
B2D
B2E
VVD
C2A*
C2B*
C2C
C2D
C2E
VVT
-
-
D2C
D2D
D2E
VH
(Vertical/Horizontal)
VV
(Vertical/Vertical)
VVD
(Vertical/Vertical/
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
*Not available on Model 221.
Step 4: Trim Material
201 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
Designator
Float Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
15/60
200 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on
a level switch changes, the Set Points will also change. These values are based on the
specific gravity listed and units with “B” trim and an A1 switch. For other materials or
switches, please consult factory. If a specific Set Point is needed, please use the “SC”
option found in the accessories section of this catalog.
Model 201
Model 202
Model 203
“B”
“C”
Specific Gravity
“B”
“C”
Specific Gravity
“B”
“C”
.38
3-3/16”
4”
.52
3-1/4”
4-7/16”
.61
3”
4-1/16”
1.0
5-3/16”
5-9/16”
1.0
5-1/4”
5-16/16”
1.0
4-3/4”
5-7/16”
Specific Gravity
Model 206
Model 205
“B”
“C”
Specific Gravity
“B”
“C”
Specific Gravity
“B”
.91
3”
3-15/16”
.50
3”
3-11/16”
.65
3-1/2”
4-1/4”
1.0
3-3/8”
4-1/4”
5”
1.0
4-5/8”
5-1/16”
1.0
4-11/16”
Model 207
Model 209
Model 221
“B”
“C”
Specific Gravity
“B”
“C”
Specific Gravity
“B”
“C”
.61
3”
3-9/16”
.38
4-3/4”
5-1/4”
.64
2-9/16”
4-1/16”
1.0
4-5/16”
4-5/8”
1.0
7-1/4”
7-1/2”
1.0
3-13/16”
4-13/16”
DRAWING NUMBER
0390660
SALES ORDER #
Dimensions listed are for reference only and are expressed
as millimeters over inches. (Linear = mm/in.)
They are subject
LINE ITEM #
0390661
MODEL
#
SALES ORDER #dimensions are required.
to change without notice. Contact
SOR
for certified
drawings of particular models or if special
146.1
* MINIMUM
OVERHEAD CLEARANCE
DRAWING NUMBER
PURCHASE ORDER #
180.9
7.12
MODEL #
101.6
4.00
*228.6
9.00
W
L
*228.6
9.00
W
SALES ORDER
#
146.1
180.9 PURCHASE ORDER
* MINIMUM
OVERHEAD CLEARANCE
7.12DRAWING WAS CREATED 5.75
THIS
USING
REQUIRED TO
REMOVE HOUSING COVER.
THE VERTICAL_MOUNT_ASSY AND TEXT
FILE 0390660.txt LOCATED ON THE
K:\$Engineering Services\Concept text files
THEN THE DRAWING WAS CHANGED TO
DRAFT ENTITIES.
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
W
H
*228.6
9.00
ISO-9001
J REHM
DRAWN BY
ENGINEER APPROVAL
J FIFE
(VVTSCALE:
ONLY)
DRAWING SCALE
DO NOT SCALE PRINT
Model Name: MODEL NAME.DRAFT/2/0+
0390660
F SHEET
1 OF
Drawing
1
A
0390661
2
DRAWING NUMBER
EO NUMBER: 5090
SCALE: DRAWING SCALE
DRAIN CONN
1"NPT OR SW
W
1” NPT
Pneumatic
P1
(3) 1/4” NPT
ATEX
Flame Proof/IS
T6
S3 w/CL
IECEx
Flame Proof
S3
S8
J FIFE
DATE
PRODUCT CE
ALL DIMEN
UNLESS O
L
DIM DWG 200 SERIES SEALED CHAMBER
VV, VVT
DWG SIZE
Model Name: MODEL NAME.DRAFT/1/4+
N4
N7
B1
B2
I
SHEET 1 OF 1
E
F
Registered Quality System to ISO 9001
2
DWG SIZE
A
Reset Form
Drawing
0390662
Note: All process flange nipples are 1” standard.
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. (Linear = mm/in.)
**See Housing section (page 48).
***M20 adapters are brass. Contact the factory for alternate materials.
| 913-888-2630 | SORInc.com
THIS DRA
NO USE WH
HEREON, NO
MADE WITHO
REV
0390661
Model Name: MODEL NAME.DRAFT/1/3+
M20 x 1.5***
ISO-900
ENGINEER APPROVAL
TITLE
DO NOT SCALE PRINT
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
J REHM
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
REV
Reset Form
Housing**
1
CHECKED BY
355.6 3/15/11
14.00
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
DIM DWG 200 SERIES SEALED CHAMBER
VH
DRAWING NUMBER
M SMITH
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DATE
TITLE
EO1"
NUMBER:
SW 5090
THIS DRAWING WAS CREATED U
THE VERTICAL_MOUNT_ASSY AN
FILE 0390661.txt LOCATED ON
K:\$Engineering Services\Concept
THEN THE DRAWING WAS CHAN
DRAFT ENTITIES.
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
W
SORINC.COM
CHECKED BY
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
Drawing
0390660
1
5
REQUIRED TO
* MINIMUM
L
M SMITH
G 3/15/11
F
101.6
4.00
W
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
D
E
180.9
7.12
L
W
DRAWING N
LINE ITEM #
5.75
REQUIRED TO REMOVE HOUSING COVER.
101.6
4.00
16/60
“C”
Specific Gravity
Chamber Dimensions
PURCHASE ORDER #
Low
Level
Specific Gravity
Model 204
MODEL #
High
Level
Form 912 (01.15) ©SOR Inc.
TITLE
DIM DWG 200
VVD
EO NUMBER:
SCALE: DRAW
DO NOT SCALE
200 Series
Chamber Dimensions
1” Connections
Model
D1, 2
E1, 2
F4
H4
G
I1, 2
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
10-1/4
260
4-13/16
122
7-7/16
189
14
356
14
356
4-9/16
116
15-3/16
386
10-1/2
267
3-3/4
95
6-1/2
165
14
356
14
356
3-3/4
95
14-3/8
365
10-1/4
260
4-13/16
122
7-7/16
189
14
356
14
356
4-9/16
116
15-3/16
386
209
12-5/8
321
5-13/16
148
8-7/16
214
16
406
16
406
7-1/2
191
18-1/16
459
221
9
229
3-1/4
83
6
152
14
356
14
356
3-3/4
95
14-3/8
365
201
inch mm
L2
202
203
204
205
206
207
1-1/2” Connections
Model
D2
E2
F4
H4
G
I2
L2
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
inch
10-1/4
260
4-13/16
122
7-7/16
189
14
356
14
356
4-9/16
116 15-3/16
386
10-1/2
267
4
102
6-1/2
165
14
356
14
356
3-3/4
95
14-3/8
365
10-1/4
260
5-1/16
129
7-7/16
189
14
356
14
356
4-9/16
116 15-3/16
386
209
13-1/16
332
6-1/16
154
8-7/16
214
16
406
16
406
7-1/2
191 18-1/16
459
221
9
229
3-1/2
89
6
152
14
356
14
356
3-3/4
95
365
201
mm
inch
mm
202
203
204
205
206
207
14-3/8
2” Connections
Model
201
D2
E2
F4
H4
G
I2, 3
inch mm
inch
L2, 3
inch
mm
inch
mm
inch
mm
inch
mm
mm
inch
mm
10-1/4
260
5-3/8
137
7-7/16
189
14
356
14
356 5-9/16
141
16-3/16
411
10-1/2
267
4-5/16
110
6-1/2
165
14
356
14
356
4-3/4
121
15-3/8
391
10-1/4
260
5-3/8
137
7-7/16
189
14
356
14
356 5-9/16
141
16-3/16
411
13-3/8
340
6-3/16
162
8-7/16
214
16
406
16
406
191
19-1/16
484
14-3/8
365
202
203
204
205
206
207
209
221
-
-
-
-
6
152
14
356
14
356
7-1/2
5
3-3/4
5
95
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
17/60
108/208 Series
Step 1: Model Series
108 A-E1A-F-A1-N4-CRTT
The 108/208 Series mechanical level switches are float operated, horizontal mounted with sealed,
tamper-proof or flanged, serviceable chambers. Select the sensing unit from the following charts.
Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. See page 53 for pressure ratings at higher temperatures.
Pressure at Listed Temperature in psid (bar)
Model
Series
Chamber
Material
100°F
(38 C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
108
A106B
316SS
740
720
(51.0)
(49.6)
675
620
(46.5)
(42.7)
655
560
(45.1)
(38.6)
645
537
(44.4)
(37.0)
635
515
(43.7)
(35.5)
622
497
(42.8)
(34.2)
208
A106B
316SS
1794
2248
(123.6)
(155.0)
1794
1937
(123.6)
(133.5)
1794
1746
(123.6)
(120.3)
1794
1644
(123.6)
(133.4)
1794
1602
(128.0)
(110.4)
1794
1548
(128.0)
(106.7)
Minimum Specific Gravity
For all model series on this page, single switch only is equal to .65.
Consult the factory for units used with specific gravity lower than .65.
Step 2: Chamber Material
108 A-E1A-F-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
Designator
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Step 3: Process Connection
Select a process connection style and size from the chart
below. Consult the factory for variations. NPT connections
not recommended above 900°F.
Size
E1A
E1B
E5A
E5B
E2A
E2B
Style
108 A-E1A-F-A1-N4-CRTT
NPT Thread
1”
1-1/2”
2”
NPT
SW
NPT
SW
NPT
SW
Step 4: Trim Material
Select the internal trim material from the chart below.
18/60
108 A-E1A-F-A1-N4-CRTT
Designator
Float Material
Attraction Sleeve
Available with
Chamber Material:
F
321 Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
G
321 Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
108/208 Series
Chamber Dimensions
DRAWIN
MODEL #
Dimensions listed are for reference only and are expressed as millimeters
over inches. (Linear = mm/in.)
PURCHASE ORDER #0390667
MODEL
SALES ORDERdrawings
#
They# are subject to change without notice. Contact SOR for certified
of particular models or if
PURCHASE ORDER #
LINE ITEM #
special dimensions are required.
180.9
SALES ORD
DRAWING NUMBER
MODEL
180.9
7.12
101.6
4.00
Model 108
CONNECTION
SIZE
C 7.12
B
125.4 250.8
1"
4.94
9.88
128.5 257.0
1-1/2"
5.06
10.12
138.2 276.4
2"
5.44
10.88
120.7 241.3
1"
4.75
Model
208 9.50
130.3 260.6
1-1/2"
5.13
10.26
A
143.0 186.0
2" B
5.63
11.25
108A
(CS)
*228.6
9.00
108C
(316SST)
W
317.5
B
12.50
*228.6
9.00
1
208C
(316SST)
1
THIS
DRAWING WAS CREATED
W
THE HORIZ_MOUNT_ASSY AN
FILE 0390667.txt LOCATED ON
ISO-9
K:\$Engineering
Services\Conce
C
THEN THE DRAWING WAS CH
PRODUCT
DRAFT ENTITIES.
ALL DIM
UNLESS
DRAWN BY
164.3
187.3
Drawing 0390667
200.8
7.91
THIS D
NO USE W
HEREON,
MADE WIT
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
Model WITHOUT
Name: MODEL
NAME.DRAFT/2/0+
MADE
THE
EXPRESS WRITTEN PERMISSION OF SOR.
General Purpose
Explosion Proof
DIM DWG 108
SERIES HORIZONITAL
Explosion
Proof
MOUNT FLOAT OPERATED
Explosion
Proof
EO NUMBER: 5090
TITLE
146.1
DRAWING NUMBER
DRAWING
SCALE
Pneumatic
DO NOT SCALE PRINT
1” Connections
A
inch
N4
N7
B1
B2
0390667
P1
SHEET 1 OF 1
mm
inch
108
4-13/16
1
122
208
4-15/16
125
DIM DWG 20
MOUNT FLO
SCALE: DRA
REV
2
DWG SIZE
(3) 1/4” NPT
A
T6
Reset
Form
S3
w/CL
IECEx
Flame Proof
S3
S8
M20 x 1.5***
C
mm
inch
mm
9-5/8
2
244
15-1/2
394
9-7/8
250
15-5/8
396
2
EO NUMBER
1” NPT
ATEX
Flame Proof/IS
B
1
TITLE
146.1
*
OVERHEAD
CLEARANCE
W
5.75
REQUIRED TO REMOVE COVER.
3/16/11
Housing**
187.3
7.38
573.1
22.56
*
OVERHEAD CLEARANCE
* Minimum 5-3/4”
5.75(146 mm) overhead clearance REQUIRED
TO REMOVE
required to remove
housing
cover. COVER. SCALE:
**See Housing section (page 48).
***M20 adapters are brass. Contact the factory
for alternate materials.
Model
DATE
1-1/2” Connections
Model
A1
B1
C1
inch
mm
inch
mm
inch
mm
108
5-1/16
129
10-1/8
258
15-3/4
401
208
5-1/16
129
10-1/8
258
15-3/4
401
2” Connections
Model
A1
B1
C1
inch
mm
inch
mm
inch
mm
108
5-3/8
137
10-3/4
274
16-1/8
409
208
5-3/8
137
10-3/4
274
16-1/8
409
Notes 1. Dimensions valid for socket weld process connections.
Consult factory for threaded connection dimensions.
Form 912 (01.15) ©SOR Inc.
SORInc.com
CONN
S
208A
(CS)
101.6
4.00
M SMITH
6.47 DRAWING
7.38
PRODUCT CERTIFICATION
CHECKED BY
ALL DIMENSIONS ARE ±1/16 IN 500.0
J REHM
UNLESS OTHERWISE SPECIFIED 19.69
ENGINEER APPROVAL
MM
LINEAR =
J FIFE
IN
Drawing 0390666
Model Name: MODEL NAME.DRAFT/2/0+
399.0
15.71
402.1
15.83
411.7
16.21
394.2
15.52
403.9
15.90
416.6
16.40
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
C
A
A
MODEL
| 913-888-2630 | Registered Quality System to ISO 9001
19/60
DO NOT SC
300 Series
Step 1: Model Series
301 A-F1A-B-A1-N4-CRTT
The 300 series mechanical level switches are float-operated switches suitable for top-insertion
mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for
switching elements, housings and accessories. Select a model series from the charts below based
on maximum operating pressure and minimum specific gravity.
Pressure at Listed Temperature in psid (bar)*
Model
Series
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
301
225
(15.5)
225
(15.5)
225
(15.5)
219
(15.1)
213
(14.6)
207
(14.2)
303
500
(34.4)
500
(34.4)
500
(34.4)
486
(33.5)
473
(32.6)
460
(31.7)
304
750
(51.7)
750
(51.7)
750
(51.7)
729
(50.2)
709
(48.8)
690
(47.5)
*Consult the factory for pressure ratings of units with Monel trim.
Minimum Specific Gravity
Minimum specific gravity will be lower for shorter insertion depths. Consult the factory.
Model Series Insertion Depth*
Minimum Specific Gravity Single Switch
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
316SS / 400SS
Trim (B)
All 316SS Trim (C)
All Monel Trim (M)
301
24”
48”
.40
.44
(.45)
(.49)
.42
.46
(.48)
(.52)
.48
.53
(.54)
(.59)
303
24”
48”
.68
.75
(.79)
(.87)
.72
.80
(.84)
(.91)
.82
.91
(.93)
(1.02)
304
24”
48”
.52
.56
(.58)
(.62)
.55
.59
(.61)
(.65)
.62
.67
(.68)
(.73)
*Insertion depth is defined as the approximate value of a rising level setpoint at a Specific Gravity of 1.0.
If more precise setpoint action is required, please select the SC option from the accessories section of the
catalog. Please note: An insertion depth or SC information must be supplied at the time of order on all 300
series switches.
Step 2: Process Connection Material
301 A-F1A-B-A1-N4-CRTT
Select process connection material from the following chart.
Designator
20/60
Material
A
A106 Carbon Steel
C
A182-TP316/316L Stainless Steel
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
300 Series
Step 3: Process Connection
301 A-F1A-B-A1-N4-CRTT
Select a process connection, size and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Select Designator
Flange
Size
NPT
Thread
150#
300#
600#
1”
F1A
-
-
-
2”
F2A
-
-
-
3”
F3A
F3C
F3D
F3E
4”
-
F4C
F4D
F4E
6”
-
F6C
F6D
F6E
NPT Mounting
Flange Mounting
Note: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has
access to attach the float from inside the vessel after instrument installation. See page 22 for float
dimensions.
Step 4: Trim Material
301 A-F1A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.
Designator
Float Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
21/60
300 Series
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
MODEL #
Standard Units
SALES ORDER #
LINE ITEM #
180.9
7.12
FLOAT SIZ
139.7
5.50
88.9 15
X
3.5
6.0
13.7
5.50
301
180.9
7.12
101.6
4.00
101.6
4.00
MODEL
303
180.9
7.12
180.9
7.12
101.6
4.00
PURCHASE ORDER #
Tandem Float
Units
MODEL
MODEL
301/304
303
101.6
4.00
304
146.1
OVERHEAD CLEARAN
5.75
REQUIRED TO REMOVE C
*
227.0
8.94
227.0
8.94
227.0
8.94
W
W
62.7
2.47
W
99.2
3.91
227.0
8.94
W
PROCESS
CONNECTION
FLANGE D
PROCESS
CONNECTION
FLANGE B
C
PROCESS
CONNECTION
1 NPT(M)
DIFFERENTIAL "C" : __________
A
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
B
CHECKED BY
ENGINEER APPROVAL
J FIFE
DATE
3/6/12
Drawing
0390053
E IS BASED ON MINIMUM DIFFERENTIAL SETTING,
LIQUID SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION.
MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE
TO PROVIDE FLOAT INSERTION CLEARANCE.
Drawing
0390007
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
FLOAT
M SMITH
C
DIM DWG 300 SERIES 1" NPT
1. FLOAT SIZE IS BASED ON MINIMUM DIFFERENTIAL SETTING,
(FLOAT OPERATED)
MINIMUM LIQUID SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION.
EO NUMBER: 5154
2. CAUTION MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE
SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE.
M SMITH
ISO-9001
ENGINEER APPROVAL
DATE
3/6/12
C
LOWER FLOAT
DRAWING NUMBER
EO NUMBER: 5154
0390007
SCALE: 0.33
B
SHEET 1 OF 1
DO NOT SCALE PRINT
REV
Drawing
0390665
4
DWG SIZE
B
NOTE:
1. FLOAT SIZE IS BASED ON MINIMUM DIFFERENTIAL SETTING,
MINIMUM
SPECIFIC GRAVITY,
AND SINGLE
SWITCH FUNCTION.
Minimum 5-3/4’’ (146 mm) overhead clearance required
toLIQUID
remove
housing
cover.
2. CAUTION MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE
2
Housing**
***M20 adapters are brass.
Contact the factory for alternate materials.
1” NPT
Pneumatic
P1
(3) 1/4” NPT
ATEX
Flame Proof/IS
T6
S3 w/CL
IECEx
Flame Proof
S3
S8
Series
303
Minimum
Insertion
Float Size
mm
inch
3-1/2 x 6”
114
4-1/2
5-1/2”
108
4-1/4
301
304
Maximum
Insertion
mm
inch
1219
48
M20 x 1.5***
Tandem Float Units
High Insertion
Series
303
301
304
Float Size
Minimum
Low Insertion
Differential
Maximum
Minimum
Maximum
Minimum
Maximum
mm
inch
mm
inch
mm
inch
mm
inch
mm
inch
mm
inch
3-1/2 x 6”
114
4-1/2
1016
40
305
12
1219
48
203
8
1105
43-1/2
5-1/2”
108
4-1/4
1041
41
279
11
1219
48
178
7
1111
43-3/4
Notes
1. Standard Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection, or that the vessel has access to attach the float from inside the vessel after instrument installation.
2. Tandem Float Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection. Tandem floats are not removable and must be installed through the nozzle opening. Operating specific gravity and insertion depths must be specified.
22/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
DIM DWG 300 SERIES FLANGED
(FLOAT OPERATED)
DO NOT SCALE PRINT
Standard Units
W
N4
N7
B1
B2
TITLE
SCALE: 0.20
Model Name: 0390665_OPT.ASSEM//0
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
THIS DRAWING IS THE EXCLUSI
NO USE WHATSOEVER OF THE INF
HEREON, NOR REPRODUCTION IN
MADE WITHOUT THE EXPRESS WRIT
EO NUMBER: 5195
SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE.
** See Housing section (page 48).
PRODUCT CERTIFICATION DRA
ALL DIMENSIONS ARE ±1/1
UNLESS OTHERWISE SPECIF
MM
LINEAR =
IN
DIM DWG 300 SERIES FLANGED
FLOAT OPERATED
4
DWG SIZE
M/3/3+
Model Name: 0390007.ASSEM/3/0+
14685 W 105TH S
91
SO
J FIFE
LOWER FLOAT
REV
0390053
SHEET 1 OF 1
DO NOT SCALE PRINT
CHECKED BY
TITLE
DRAWING NUMBER
SCALE: 0.33
ELECTRICAL CONN. "W" : _____
J REHM
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
FLANGE "D" : ______________
B
DRAWN BY
J REHM
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
NOTES:
UPPER FLOAT
UPPER FLOAT
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
DRAWN BY
HIGH INSERTION DEPTH "A" : _
LOW INSERTION DEPTH "B" : _
A
FLOAT
PROCESS
CONNECTION
FLANGE D
62.7
2.47
Form 912 (01.15) ©SOR Inc.
DRAWING
SH
400 Series
Step 1: Model Series
401 A-G3A-B-A1-N4-CRTT
The 400 Series mechanical level switch is float operated suitable for horizontal-insertion mounting.
Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
Pressure at Listed Temperature in psig (bar)*
Model
Series
Chamber
Material
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
401
A106B
316SS
230
(15.8)
230
(15.8)
230
(15.8)
224
(15.4)
218
(15.0)
212
(14.6)
402
A106B
316SS
350
(24.1)
350
(24.1)
350
(24.1)
340
(23.4)
331
(22.8)
322
(22.2)
403
A106B
316SS
230
(15.8)
230
(15.8)
230
215
(15.8)
(14.8)
215
205
(14.8)
(14.1)
200
195
(13.7)
(13.4)
185
182
(12.7)
(12.5)
404
A106B
316SS
500
(34.4)
500
(34.4)
500
(34.4)
486
(33.5)
473
(32.6)
460
(31.7)
405
A106B
316SS
740
720
(51.0)
(49.6)
675
620
(46.5)
(42.7)
655
560
(46.1)
(38.6)
645
537
(44.4)
(37.0)
635
515
(43.7)
(35.5)
618
497
(42.6)
(34.2)
406
A106B
316SS
1250
(86.2)
1250
1240
(86.2)
(85.5)
1250
1120
(86.2)
(77.2)
1216
1075
(83.8)
(74.1)
1182
1030
(81.5)
(71.0)
1150
992
(79.3)
(68.4)
*Consult the factory for pressure ratings of units with Monel trim
Minimum Specific Gravity
Model
Single Switch
401
.50
402
.90
403
.50
404
.60
405
.60
406
.60
Note: Insertion depth may affect minimum specific gravity.
Step 2: Chamber Material
401 A-G3A-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
Designator
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
23/60
400 Series
Step 3: Process Connection
401 A-G3A-B-A1-N4-CRTT
Select a process connection designator from the chart below based on style and size. Consult the factory for
variations. 3” flanged process connections may require the float to be installed from inside the process connection.
Connection
Model
Float
Size
Designator
Size
401
3”
G3A
3”
NPT(M)
Thread
402
2-1/2”
G7A
2-1/2”
NPT(M)
Thread
403
3”
403
3”
404
3 x 6”
G3F
G4F
G3A
3”
4”
3”
Style
150# RF
Weld Neck
Flange
150# RF
Weld Neck
Flange
NPT(M)
Thread
Connection
Model
Float
Size
Designator
Size
Style
405
3 x 6”
G3G
3”
300# RF
Weld Neck
Flange
405
3 x 6”
G4G
4”
300# RF
Weld Neck
Flange
406
3 x 6”
G3H
3”
600# RF
Weld Neck
Flange
406
3 x 6”
G4H
4”
600# RF
Weld Neck
Flange
Step 4: Trim Material
401 A-G3A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Designator
Float Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or 316/316L
Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or 316/316L
Stainless Steel (C)
Chamber Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory
for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches.
(Linear = mm/in.)
Housing**
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
Models 403, 405, 406
Models 401, 402, 404
Drawing
0390668
Drawing
0390669
MODEL #
217.5
8.56
Pneumatic
SALES ORDER #
LINE ITEM #
N
ATEX
Flame Proof/IS
101.6
4.00
(3) 1/4”
NPT
T6
MODEL
S3
403
w/CL
MAXIMUM DIFFERENTIAL (D)
FLANGED
UNITS
S3
406**
S8
Flame Proof
W
P1
405**
IECEx
*227.0
8.94
1” NPT
PURCHASE ORDER #
1
180.9
7.12
W
N4
N7
B1
B2
NOZZLE LENGTH (N)
51
2.0
102
4.0
M20229
x
9.0
1.5***
152
330
13.0
152
6.0
203
8.0
254
10.0
178
7.0
127
5.0
114
4.5
127
5.0
6.0
**BASED ON 4" FLANGE SIZE
CUSTOMER
PROCESS
CONNECTION
STANDARD DIFFERENTIAL (D)
MODEL
*Minimum 146.1 overhead clearance required to remove
5.75 housing cover.
** See Housing section (page 48).
***M20 adapters are brass. Contact the factory for alternate
materials.
"D" @ MIN. S.G.
51
2.0
403
118.3
4.66
405
FLOAT
44.5
1.75
406
D 1
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
DRAWN BY
PROCESS
CONNECTION
WELD NECK
FLANGE
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
J REHM
ENGINEER APPROVAL
J FIFE
DATE
08 APR 2011
457
18.0
263.5
10.38
K MITCHELL
CHECKED BY
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
146.1
OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
DIM DWG 403,405,406
FLOAT OPERATED
* MINIMUM
24/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
ELECTRICAL CONN. "W" : __________
Model Name: 0390669.ASSEM/1/5+
NOTES:
1
EO NUMBER: 5090
Form 912 (01.15) ©SOR Inc.
1. STANDARD DIFFERENTIAL. FOR MAXIMUM DIFFERENTIAL, SEE TABLE.
SCALE: 0.33
DO NOT SCALE PRINT
DRAWING NUMBER
REV
0390669
2
SHEET 1 OF 1
DWG SIZE
B
Reset Form
400 Series
Calibration Dimensions
Standard Differential (D)
Model
“D” @ Minimum Specific Gravity
401
402
Note: With anti-vibration, extra-high
temperature and pneumatic switch,
minimum differential will increase.
3” (76 mm)
403
404
405
2-3/4” (70 mm)
406
Maximum Differential (D)
Differential Dimension “D” is calibrated to the minimum shown above as standard. Wider
differentials are available by placing an SC in the accessory section of the model number.
The charts below give the maximum differentials available.
NPT Units
Customer Mounting
Model
1/2 Coupling
Full Coupling
401
12-3/8”
(356 mm)
10-1/4”
(292 mm)
402
8-7/8”
(292 mm)
8-7/8”
(292 mm)
404
12-3/8”
(356 mm)
10-1/4”
(292 mm)
Flanged Units
Model
403
Customer Nozzle Length (N)
2”
(51 mm)
4”
(102 mm)
6”
(152 mm)
8”
(203 mm)
10”
(254 mm)
13”
(330 mm)
9”
(229 mm)
7”
(178 mm)
5”
(127 mm)
4-1/2”
(114 mm)
405*
406*
6” (152 mm)
5” (127 mm)
*Based on 4-inch flange size.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
25/60
741-743 and
802 Series
Step 1: Model Series
741 A-A1C -B-A1-N4-CRTT
The 741-743 and 802 Series mechanical level switches are displacer-operated with flanged, serviceable external chambers. Select the sensing unit from the following charts. Then refer to pages
44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
Pressure at Listed Temperature in psig (bar)*
Model
Series
Chamber
Material
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
741
A106B
316SS
285
275
(19.7)
(18.9)
260
240
(17.4)
(16.5)
230
215
(15.8)
(14.8)
215
205
(14.8)
(14.1)
200
195
(13.7)
(13.4)
185
182
(12.7)
(12.5)
742
A106B
316SS
740
720
(51.0)
(49.6)
680
620
(46.9)
(42.7)
655
560
(45.1)
(38.6)
645
537
(44.4)
(37.0)
635
515
(43.7)
(35.5)
618
497
(42.6)
(34.2)
743
A106B
316SS
1480
1440
(102.0)
(99.3)
1294
1240
(89.2)
(85.5)
1166
1120
(80.4)
(77.2)
1118
1075
(77.1)
(74.1)
1070
1025
(73.8)
(70.7)
1034
990
(71.3)
(68.3)
802
A106B
316SS
3376
3600
(232.8)
(248.2)
3376
3095
(232.8)
(213.4)
3270
2795
(225.5)
(192.7)
3220
2683
(222.0)
(185.0)
3170
2570
(218.6)
(177.2)
3092
2480
(213.2)
(171.0)
*Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are
not available above 450°F (232°C).
Minimum Specific Gravity
Model
Series
Standard
Anti-Vibration
or Pneumatic
0.43
0.57
0.41
0.5
741
742
743
802
Step 2: Chamber Material
741 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternate materials.
Designator
26/60
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
741-743 and
802 Series
Step 3: Process Connection
741 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
1”
1-1/2”
2”
Style
NPT
Thread
Socket
Weld
VH
A1A
VV
Flange
150#
RF
300# 600# 1500#
RF
RF
RTJ
A1B
A1C
A1D
A1E
A1T
-
-
B1C
B1D
B1E
B1T
VVD
C1A
C1B
C1C
C1D
C1E
C1T
VVT
-
-
D1C
D1D
D1E
D1T
VH
A5A
A5B
A5C
A5D
A5E
A5T
VV
-
-
B5C
B5D
B5E
B5T
VVD
C5A
C5B
C5C
C5D
C5E
C5T
VVT
-
-
D5C
D5D
D5E
D5T
VH
A2A*
A2B*
A2C
A2D
A2E
A2T
VV
-
-
B2C
B2D
B2E
B2T
VVD
C2A*
C2B*
C2C
C2D
C2E
C2T
VVT
-
-
D2C
D2D
D2E
D2T
VV
VH
(Vertical/Horizontal) (Vertical/Vertical)
VVD
(Vertical/Vertical/
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
*Not available on Models 741, 742, and 743.
Step 4: Trim Material
741 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.
Designator
Displacer Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
27/60
741-743 and
802 Series
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.
Model 802
Model 741, 742, 743
Specific
Gravity
“B”
“C”
Specific
Gravity
“B”
“C”
.43
1-13/16”
4-5/8”
.41
2-3/8”
5-5/16”
1.0
4-9/16”
6-1/16”
1.0
5-1/16”
6-7/16”
Chamber Dimensions
DRAWING NUMBER
MODEL as
#
Dimensions listed are for reference only and are expressed
millimeters
over inches. (Linear = mm/in.)
0390019
PURCHASE ORDER #
SALES
ORDER
#
They are subject to change without notice. Contact SOR for certified drawings of particular models or if
PURCHASE ORDER #
LINE ITEM #
special dimensions are required.
SALES ORDER #
DRAWING NUMBER
MODEL #
101.6
4.00
* MINIMUM
*228.6
9.00
W
180.9
7.12
146.1
OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
180.9
7.12
146.1
5.75
REQUIRED TO REM
* MINIMUM
101.6
4.00
THIS DRAWING WAS CREATED USING
THE *228.6
VERTICAL_MOUNT_ASSY AND TEXT
9.00
FILE 0390019.txt
LOCATED ON THE
K:\$Engineering Services\Concept text files
L
THEN
THE DRAWING WAS CHANGED TO
DRAFT ENTITIES.
W
L
W
W
14685
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
PRODUCT CERTIF
ALL DIMENSIO
UNLESS OTHE
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
D
H
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
LINEA
G
J FIFE
THIS DRAWING
NO USE WHATSOE
HEREON, NOR REP
MADE WITHOUT TH
DATE
3/14/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
1" SW
(VVT
ONLY)
DIM DWG 100 SERIES
SERVICEABLE
E
Drawing 0390019
F
EO NUMBER: 5090
DRAWING NUMBER
MODEL #
0390019
Note: All process flange nipples are 1” standard.
Model Name: MODEL NAME.DRAFT/3/1+
Housing**
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
Pneumatic
ATEX
Flame Proof/IS
P1
(3) 1/4”
NPT
T6
S3 w/CL
S3
S8
M20 x
1.5***
0390010
SCALE: DRAWING
S
DO NOT SCALE PRINT
LI
DWG SIZE
A
180.9
7.12
Reset Form
101.6
4.00
W
1” NPT
DRAWING NUMBER
SALES ORDER #
3
W
N4
N7
B1
B2
EO NUMBER: 5090
Drawing 0390021
REV
DO NOT SCALE PRINT
Flame Proof
DIM DWG 100 SERI
EXTERNAL CHAMBE
F
EXTERNAL CHAMBER VH STYLE
PURCHASE ORDER #
SCALE: DRAWING
Model Name: SCALE
MODEL NAME.DRAFT/3/0+
SHEET 1 OF 1
IECEx
TITLE
TITLE
146.1
OVERHEA
5.75
REQUIRED TO REMOVE HOU
* MINIMUM
*228.6
9.00
L
W
*Minimum 5-3/4’’ (146 mm)
overhead clearance required
to remove housing cover.
**See Housing section.
(Page 48.)
***M20 adapters are brass. Contact the factory for
alternate materials.
DRAIN CONN
1"NPT OR SW
14685 W 105TH ST
913
SOR
ISO-9001
PRODUCT CERTIFICATION DRA
ALL DIMENSIONS ARE ±1/1
UNLESS OTHERWISE SPECIF
MM
LINEAR =
IN
355.6
14.00
THIS DRAWING IS THE EXCLUSI
NO USE WHATSOEVER OF THE IN
HEREON, NOR REPRODUCTION IN
MADE WITHOUT THE EXPRESS WRI
I
TITLE
E
F
Drawing 0390010
DIM DWG 100 SERIES SERVICEAB
EXTERNAL CHAMBER VVD STYLE
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
Model Name: MODEL NAME.DRAFT/3/0+
28/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
DRAWING
SH
741-743 and
802 Series
Chamber Dimensions
1” Connections
Model
D1, 2
E1, 2
F4
inch
mm
inch
mm
13
330
3-1/4
83
H4
G
inch mm inch
mm
I2
inch mm
L2
inch
mm
3-3/4
95
741
742
6
152
16
406
16
406
743
802
12-3/4
324
3-7/8
98
8
203
16
406
16
406
6-3/4
171
inch
mm
19-5/16
491
19-1/2
495
19-7/8
505
20-3/4
527
1-1/2” Connections
Model
D2
inch
E2
mm
inch
F4
mm
H4
G
inch mm
inch
mm
I2
inch mm
inch
L2
mm
741
742
13
330
3-1/2
89
6
152
16
406
16
406
3-3/4
95
743
802
12-7/8
327
4
102
8
203
16
406
16
406
6-3/4
171
inch
mm
19-5/16
491
19-1/2
495
19-7/8
505
20-3/4
527
2” Connections
Model
D2
inch
E2
mm
inch
F4
mm
H4
G
inch mm
inch
mm
I2, 3
inch mm
inch
L2, 3
mm
742
-
-
-
-
6
152
16
406
16
406
3-3/45
955
743
802
inch
mm
19-5/165 4915
741
13-3/16
335
4-5/16
110
8
203
16
406
16
406
7-3/4
197
19-1/25
4955
19-7/85
5055
21-5/16
541
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
29/60
740 and 804 Series
Step 1: Model Series
740 A-A1C-B-A1-N4-CRTT
The 740 and 804 Series mechanical level switches are displacer operated with sealed,
tamper-proof external chambers. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
Model
Series
Chamber
Material
740
804
Pressure at Listed Temperature in psig (bar)*
100°F
(38°C)
200°F
(93°C)
300°F
(149°C)
350°F
(177°C)
400°F
(204°C)
450°F
(232°C)
A106B
316SS
1480
(102.0)
1465
(101.0)
1450
(100.0)
1436
(99.0)
1420
(97.9)
1380
(95.1)
A106B
316SS
3376
3728
(232.8)
(257.0)
3376
3647
(232.8)
(251.5)
3376
3286
(232.8)
(226.6)
3376
3151
(232.8)
(217.3)
3376
3016
(232.8)
(207.9)
3376
2915
(232.8)
(201.0)
*Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available
over 450oF (232oC).
Minimum Specific Gravity
Model
Series
Standard
Anti-Vibration
or Pneumatic
740
0.43
0.57
804
0.41
0.50
Step 2: Chamber Material
740 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
Designator
30/60
Material
A
A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C
A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
740 and 804 Series
Step 3: Process Connection
740 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
1”
1-1/2”
2”
Style
NPT
Thread
Socket
Weld
VH
A1A
A1B
Flange
150#
RF
300#
RF
600#
RF
1500#
RTJ
A1C
A1D
A1E
A1T
VV
-
-
B1C
B1D
B1E
B1T
VVD
C1A
C1B
C1C
C1D
C1E
C1T
VVT
-
-
D1C
D1D
D1E
D1T
VH
A5A
A5B
A5C
A5D
A5E
A5T
VV
-
-
B5C
B5D
B5E
B5T
VVD
C5A
C5B
C5C
C5D
C5E
C5T
VVT
-
-
D5C
D5D
D5E
D5T
VH
A2A*
A2B*
A2C
A2D
A2E
A2T
VV
-
-
B2C
B2D
B2E
B2T
VVD
C2A*
C2B*
C2C
C2D
C2E
C2T
VVT
-
-
D2C
D2D
D2E
D2T
VH
(Vertical/Horizontal)
VV
(Vertical/Vertical)
VVD
(Vertical/Vertical/
Drain)
VVT
(Vertical/Vertical/
Tee Drain)
*Not available on Model 740.
Step 4: Trim Material
740 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
Designator
Displacer Material
Attraction Sleeve
Available with
Chamber Material:
B
316/316L Stainless Steel
400 Stainless Steel
A106 Carbon Steel (A) only
C
316/316L Stainless Steel
316/316L Stainless Steel
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
M
Monel 400
Monel 400
A106 Carbon Steel (A) or
316/316L Stainless Steel (C)
Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found
in the accessories section of this catalog.
Model 740
Specific
Gravity
“B”
.43
1.0
Model 804
“C”
Specific
Gravity
1-13/16”
4-5/8”
4-9/16”
6-1/16”
Form 912 (01.15) ©SOR Inc.
“B”
“C”
.41
2-3/8”
5-5/16”
1.0
5-1/16”
6-7/16”
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
31/60
DRAWING NUMBER
0390661
740 and 804 Series
Chamber Dimensions
MODEL #
SALES ORDER #
PURCHASE ORDER #
Dimensions listed are for reference only and are expressed as millimeters
over inches. (Linear = mm/in.) They are subject to change without notice.
Contact SOR for certified drawings of particular models or if special
dimensions are required.
146.1
OVERH
5.75
REQUIRED TO REMOVE H
180.9
7.12
* MINIMUM
101.6
4.00
DRAWING NUMBER
0390660
MODEL #
SALES ORDER #
PURCHASE ORDER #
W
*228.6
LINE ITEM # 9.00
L
146.1
OVERHEAD CLEARANCE
5.75
W
REQUIRED TO REMOVE HOUSING COVER.
* MINIMUM
Housing**
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
180.9
7.12
W
N4
N7
B1
B2
1” NPT
*228.6
9.00
W
P1
(3) 1/4” NPT
ATEX
Flame Proof/IS
T6
S3 w/CL
IECEx
S3
S8
Flame Proof
THIS DRAWING
WAS CREAT
PRODUCT CERTIFICATION
ALL DIMENSIONS ARE ±
THE VERTICAL_MOUNT_AS
UNLESS OTHERWISE SP
FILE 0390660.txt LOCATED
MM
LINEAR =
IN
K:\$Engineering Services\Co
THEN THE DRAWING
WAS
THIS DRAWING IS THE EXC
NO USE WHATSOEVER OF TH
DRAFT ENTITIES.
HEREON, NOR REPRODUCTIO
G
L
Pneumatic
14685 W 105TH
9
ISO-9001
101.6
4.00
MODEL #(VVT
W
DRAWING NUMBER
MADE
WITHOUT THE EXPRESS
1" SW
ONLY)
F
PURCHASE ORDER #
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
Drawing 0390661
SORINC.COM
180.9
7.12
ISO-9001
DRAWN BY
Model Name: MODEL NAME.DRAFT/1/4+
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
D
M20 x 1.5***
H
W
M
SMITH
101.6
CHECKED BY
4.00
J REHM
VV, VVT
LIN
EO NUMBER: 5090
DRA
SCALE: DRAWING
146.1 SCALE
* MINIMUM
OVERHEA
DO NOT
SCALE PRINT
5.75
REQUIRED TO REMOVE HOU
ENGINEER APPROVAL
J FIFE
DATE
*228.6
3/15/11
9.00
THIS DRAWING IS THE EXCLUSIVE LPROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION
W OF SOR.
*Minimum 5-3/4’’ (146 mm) overhead
clearance required to remove housing cover.
**See Housing section (page 48).
***M20 adapters are brass. Contact the factory
for alternate materials.
E
F
TITLE
Drawing 0390660
DIM DWG 200 SERIES SEALED CHAMBER
VH
DRAWING NUMBER
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
14685 W 105TH ST
913SOR
ISO-9001
REV
0390660
355.6
SHEET
14.001 OF 1
Model Name: MODEL NAME.DRAFT/2/0+
2
DWG SIZE
A
Reset Form
PRODUCT CERTIFICATION DRA
ALL DIMENSIONS ARE ±1/1
UNLESS OTHERWISE SPECIF
MM
LINEAR =
IN
THIS DRAWING IS THE EXCLUSI
NO USE WHATSOEVER OF THE INF
HEREON, NOR REPRODUCTION IN
MADE WITHOUT THE EXPRESS WRIT
I
TITLE
Note: All process flange nipples are 1” standard.
DRAIN CONN
1"NPT OR SW
1” Connection
Drawing 0390662
E
F
D1, 2
E1, 2
F4
H4
G
inch mm inch
mm
I2
inch mm
L2
inch
mm
inch
mm
inch
mm
inch
mm
740
13
330
3-1/4
83
6
152
16
406
16
406
3-3/4
95
20-1/4
514
804
12-3/4
324
3-7/8
98
8
203
16
406
16
406
6-3/4
171
21-3/4
552
1-1/2” Connection
Model
D2
E2
F4
H4
G
inch
mm
inch
mm
740
13
330
3-1/2
89
6
152
16
406
16
804
12-7/8
327
4
102
8
203
16
406
16
inch mm inch
mm
I2
inch mm
L2
inch
mm
inch
mm
406
3-3/4
95
20-1/4
514
406
6-3/4
171
21-3/4
552
2” Connection
Model
D2
inch
E2
mm
inch
F4
mm
H4
G
inch mm inch
mm
I2, 3
inch mm
inch
L2, 3
mm
5
inch
mm
5
5
740
-
-
-
-
6
152
16
406
16
406
3-3/4
95
20-1/4
5145
804
13-3/16
335
4-5/16
110
8
203
16
406
16
406
7-3/4
197
21-3/4
552
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
32/60
DIM DWG 200 SERIES SEALED CH
VVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
Model Name: MODEL NAME.DRAFT/1/3+
Model
0390662
TITLE
SALES
ORDER
# SERIES SEALED
DIM DWG
200
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
DRAWING
SH
700 Series
Step 1: Model Series
702 A-F7A-B-A1-N4-CRTT
The 700 Series mechanical level switches are single-stage, displacer-operated switches suitable
for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. Minimum specific gravity is based on single switch. Anti-vibration and pneumatic
switches have higher minimum specific gravities.
Maximum Working Pressure
Model
Series
Minimum
Specific
Gravity
701
0.51
702
0.45
703
0.51
704
Function
Connection
Style
NPT
Narrow
Differential
0.45
Flange
705
NPT
707
0.50
Connection
Material
100°F
(38°C)
450°F
(232°C)
Porcelain
All
1000
(69)
750
(52)
SS
All
1000
(69)
750
(52)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
Porcelain
All
1000
(69)
750
(52)
SS
All
1000
(69)
750
(52)
A105
285
(20)
185
(13)
316SS
275
(20)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
Porcelain
Flange
706
Wide
Differential
708
Flange
Pressure Rating - psig (bar)
Displacer
Material
SS
Porcelain
Flange
SS
Displacer units are not available over 450°F (232°C).
*An operating specific gravity is required for models 705 through 708 at time of order.
Step 2: Process Connection Material
702 A -F7A-B-A1-N4-CRTT
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
Designator
Material
A
A105 Carbon Steel fittings or flanges
C
A182-TP316/316L Stainless Steel fittings or flanges
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
33/60
700 Series
Step 3: Process Connection
702 A -F7A-B-A1-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
Style
2-1/2”
3”
4”
6”
Model
701
702
703
704
705
706
707
708
NPT
F7A
F7A
-
-
F7A
F7A
-
-
NPT
F3A
F3A
-
-
F3A
F3A
-
-
150# RF Flange
-
-
F3C
F3C
-
-
F3C
F3C
300# RF Flange
-
-
F3D
F3D
-
-
F3D
F3D
150# RF Flange
-
-
F4C
F4C
-
-
F4C
F4C
300# RF Flange
-
-
F4D
F4D
-
-
F4D
F4D
150# RF Flange
-
-
F6C
F6C
-
-
F6C
F6C
300# RF Flange
-
-
F6D
F6D
-
-
F6D
F6D
Step 4: Trim Material
702 A -F7A-B-A1-N4-CRTT
Select the internal trim material from the chart below.
Model
Displacer
Material
Attraction
Sleeve
Construction
Material
701
702
703
704
705
706
707
708
316/316L SS
400SS
A only
-
B
-
B
-
B
-
B
316/316L SS
316/316L SS
A or C
-
C
-
C
-
C
-
C
Porcelain
400SS
A only
P
-
P
-
P
-
P
-
Porcelain
316/316L SS
A or C
R
-
R
-
R
-
R
-
Standard displacer spring material is Inconel 600.
34/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
700 Series
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 701/703
2-1/2” NPT/Flanged
Narrow Differential
MODEL #
MODEL #
SALES ORDER #
Model 702/704
2-1/2” NPT/Flanged
Narrow Differential
SALES ORDER #
LINE ITEM #
LINE ITEM #
PURCHASE ORDER #
1
SALES PAGE
146.1
OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
* MINIMUM
PURCHASE ORDER #
NPT A
180.9
7.12
180.9
180.9
7.12
7.12
101.6
4.00
180.9
FLANGE B
7.12
Narrow Differential
Models 701-704:
101.6
4.00
Actuation differential
is approximately
1-7/16’’ @ Specific Gravity of 1.0 @ 100°F.
101.6
4.00
101.6
4.00
DIMENSION C
SEE CHART
DIMENSION D
SEE CHART
ELECTRICAL CONNECTION W
*227.0
8.94
DIMENSION C
*227.0
*227.0
8.94
8.94
W
W
PROCESS
CONNECTION
NPT A
D
*227.0
SIZE
8.94
W
PROCESS
CONNECTION
PROCESS
2-1/2CONNECTION
NPT(M)(STD)
3 NPT(M)(OPT)
FLANGE B
C
3048
120.0
316 SST
CABLE
3048
3048
120.0
316 120.0
SST
316 SST
CABLE
LOW
3 NPTM
316 SST146.1 OVERHEAD CLEARANCE
* MINIMUM
CABLE5.75
REQUIRED TO REMOVE HOUSING COVER
14685 W 105TH ST LENEXA, KS 66215 USA
HIGH
913-888-2630
SORINC.COM
ISO-9001
HIGH
SWITCH
ACTUATIONSWITCH
195.6
316 SST
7.70
DISPLACER
LOW
PORCELAIN
DISPLACER
MODEL
701
Drawing
0390670
SCALE 0.25
84.9
3.34
87.9
3.46
2-1/2 NPTM
MINIMUM
229
9.0
PORCELAIN
DISPLACER
65.7
TITLE
MODEL
DIMENSION DRAWING 701, 703
NARROW DIFFERENTIAL
SCALE
703
DrawingMODEL
0390671
EO NUMBER: 4441
Pneumatic
SCALE 0.25
J REHM
LOW
ENGINEER APPROVAL
R SAVERINO
DATE
27 JUL 2011
IECEx
Model 706/708
Flame Proof
2-1/2” NPT/Flanged
Wide Differential
N4
N7
B1
B2
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
1” NPT
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
REV
0390670
ATEX
Flame Proof/IS
Model Name: 0390671_704.ASSEM/1/4+
704
0.2
1
SHEET 1 OF 1
Model Name: 0390670.ASSEM/1/7+
Model 705/707
CHECKED BY
DRAWING NUMBER
SCALE: 0.25
DO NOT SCALE PRINT
2-1/2” NPT/Flanged
Wide Differential
K MITCHELL
ACTUATION
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
MODEL 702
2.59
SCALE 0.2
W
ISO-9001
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
LOW
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
Housing** SWITCH
190.5
7.50
316 SST
General
Purpose
DISPLACER
Explosion Proof
Explosion 63.5
Proof
2.50
Explosion Proof
ACTUATION
63.5
2.50
65.7
2.59
70.6
2.78
77.0
3.03
86.6
3.41
62.7
2.47
64.3
2.53
4"
HIGH
190.5
7.50
HIGH
SWITCH
ACTUATION
600 #
67.6
2.66
70.6
2.78
75.4
2.97
DIMENSION D
MINIMUM
229
9.0
CABLE
195.6
7.70
300 #
PROCESS
Wide Differential Models
705-708:
CONNECTION
FLANGED
Actuation differential is adjustable from
approximately
9–1/2”
62.7
2.47
(minimum
@ Specific
Gravity of 1.0 @100°F)
MINIMUM
3048
229
to available
cable
length.
120.0
9.0
ELECTRICAL CONN. "W" : __________
6"
84.9
3.34
MINIMUM
229
9.0
FLANGE
150 #
W 62.7
3"
2.47
DWG SIZE
P1
B
Reset Form
T6
S3 w/CL
S3
S8
DIM DWG 702, 704
NARROW
DIFFERENTIAL
(3)
1/4”
NPT
EO NUMBER: 4441
DRAWING NUMBER
SCALE: 0.20
DO NOT SCALE PRINT
REV
0390671
1
SHEET 1 OF 1
DWG SIZE
B
Reset Form
M20 x 1.5***
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Switch Housing section (page 48).
*** M20 adapters are brass. Contact the factory for
alternate materials.
Drawing 0390672
Form 912 (01.15) ©SOR Inc.
Drawing 0390673
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
35/60
730 Series
Step 1: Model Series
731 A-F7A-B-A2-N4-CRTT
The 730 Series mechanical liquid level switches are dual-stage, displacer-operated switches
suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then
refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
Model
Series
Minimum
Specific
Gravity
730
0.72
731
0.64
732
0.72
733
0.64
Function
Connection
Style
NPT
Narrow
Differential
734
735
736
0.64
737
Wide
Differential
Connection
Material
100°F
(38°C)
450°F
(232°C)
Porcelain
All
1000
(69)
750
(52)
SS
Flange
Porcelain
Flange
SS
NPT
Pressure Rating - psig (bar)
Displacer
Material
Porcelain
SS
Flange
Porcelain
Flange
SS
All
1000
(69)
750
(52)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
All
1000
(69)
750
(52)
All
1000
(69)
750
(52)
A105
285
(20)
185
(13)
316SS
275
(20)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
Displacer units are not available over 450oF (232oC).
*An operating specific gravity is required for all 730 series at time of order.
Step 2: Process Connection Material
731 A -F7A-B-A2-N4-CRTT
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
36/60
Designator
Material
A
A106 Carbon Steel fittings or flanges
C
A182-TP316/316L Stainless Steel fittings or flanges
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
730 Series
Step 3: Process Connection
731 A -F7A-B-A2-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
Style
2-1/2”
3”
4”
6”
Model
730
731
732
733
734
735
736
737
NPT
F7A
F7A
-
-
F7A
F7A
-
-
NPT
F3A
F3A
-
-
F3A
F3A
-
-
150# RF Flange
-
-
F3C
F3C
-
-
F3C
F3C
300# RF Flange
-
-
F3D
F3D
-
-
F3D
F3D
150# RF Flange
-
-
F4C
F4C
-
-
F4C
F4C
300# RF Flange
-
-
F4D
F4D
-
-
F4D
F4D
150# RF Flange
-
-
F6C
F6C
-
-
F6C
F6C
300# RF Flange
-
-
F6D
F6D
-
-
F6D
F6D
Step 4: Trim Material
731 A -F7A-B-A2-N4-CRTT
Select the internal trim material from the chart below.
Model
Displacer
Material
Attraction
Sleeve
Construction
Material
730
731
732
733
734
735
736
737
316/316L SS
400SS
A only
-
B
-
B
-
B
-
B
316/316L SS
316/316L SS
A or C
-
C
-
C
-
C
-
C
Porcelain
400SS
A only
P
-
P
-
P
-
P
-
Porcelain
316/316L SS
A or C
R
-
R
-
R
-
R
-
Standard displacer spring material is Inconel 600.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
37/60
730 Series
Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 730/732
Model 731/733
2-1/2” NPT/Flanged
Narrow Differential
MODEL #
2-1/2” NPT/Flanged
Narrow Differential
SALES ORDER #
MODEL #
LINE ITEM #
PURCHASE ORDER #
SALES ORDER #
*227.0
8.94
*227.0
8.94
*227.0
8.94
W
W
W
W
MINIMUM
229
9.0
MINIMUM
MINIMUM
229 229
9.0 9.0
3048
3048120.0
120.0
316 SST
316 SST
CABLE
CABLE
HIGH
SWITCH
ACTUATION
HIGH
HIGH
195.6
7.70
LOW
SWITCH
ACTUATION
LOW
Model Name: 0390672.ASSEM/1/6+
65.7
2.59
Drawing 0390677
LOW
HIGH
195.6
7.70
LOW
SWITCH
ACTUATION
MODEL 730
SCALE 0.2
LOW HIGH
SWITCH
ACTUATION
Model Name: 0390673.ASSEM/1/7+
LOW
LOW
SWITCH
ACTUATION
FLANGE
PROCESS
CONNECTION
600
#
FLANGED
67.6
70.6
2.66
2.78
70.6
77.0
2.78
3.03
75.4
86.6
2.97
MINIMUM3.41
150 #
300 #
62.7
2.47
62.7
2.47
64.3
2.53
6"
3048
120.0
316 SST
CABLE
DIMENSION D 229
9.0
2-1/2 NPTM
3 NPTM
General Purpose
Explosion Proof
LOW
Explosion Proof
LOW
Explosion
Proof
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
HIGH
SWITCH
PRODUCT CERTIFICATION DRAWING
ACTUATION
ALL DIMENSIONS ARE ±1/16 IN
LOW
SWITCHUNLESS OTHERWISE SPECIFIED
MM
LINEAR =
ACTUATION
IN
DRAWN BY
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
Pneumatic
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001
DRAWN BY
21 JUN 2011
P1
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
TITLE
MODEL 731
MODEL 732
SCALE 0.2
SCALE 0.2
DIMENSION DRAWING 730, 732
NARROW DIFFERENTIAL
63.5
2.50 65.7
2.59
DRAWING NUMBER
63.5
0390677
SCALE: 0.20
2.50
SHEET 1 OF
MODEL 733
DO NOT SCALE PRINT
SCALE 0.2
Drawing 0390678
Model 735/737
2-1/2” NPT/Flanged
Wide Differential
2-1/2” NPT/Flanged
Wide Differential
Drawing 0390679
Drawing 0390680
Registered Quality System to ISO 9001
JFIXSEN
CHECKED BY
JKENT
ENGINEER APPROVAL
(3) 1/4”
NPT
SBOAL
DATE
2/4/03
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
T6
S3 w/
CL
TITLE
ATEX
Flame Proof/IS
EO NUMBER: 5090
Flame Proof
38/60
N4ELECTRICAL CONN. "W" : __________
N7
1” NPT
B1
B2
DATE
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
LOW
W
J FIFE
IECEx
Model 734/736
84.9
3.34
87.9
Housing**
3.46
HIGH 146.1
* MINIMUM
OVERHEAD CLEARANCE
5.75
316 SST
REQUIRED TO REMOVE HOUSING
COVER
DISPLACER
HIGH
DISPLACER
LOW
146.1
OVERHEAD CLEARANCE REQUIRED
5.75
TO REMOVE HOUSING COVER.
* MINIMUM
DIMENSION C
3"
316 SST
DISPLACER
PORCELAIN
HIGH
PORCELAIN
DISPLACER
HIGH
SWITCH
ACTUATION
SEE CHART
SIZE
62.7
2.47
HIGH
HIGH
SEE CHART
DIMENSION D
4"
84.9
3.34
PURCHASE ORDER #
NPT A
180.9
7.12
FLANGE B
101.6
4.00
DIMENSION
C
ELECTRICAL CONNECTION W
2-1/2 NPT(M)
PROCESS
CONNECTION
FLANGE B
PROCESS
CONNECTION
NPT A
3048
120.0
316 SST
CABLE
*227.0
8.94
PROCESS
C
CONNECTION
D
1
SALES PAGE
LINE ITEM #
180.9
180.9
7.12
7.12
101.6
101.6
4.00
4.00
180.9
7.12
101.6
4.00
1
REV
3
DWG SIZE
B
Reset Form
DIM DWG 731, 733
NARROW DIFFERENTIAL
EO NUMBER: 4441
SCALE: 0.20
DO NOT SCALE PRINT
S3
S8
DRAWING NUMBER
0390678
REV
1
M20 x
1.5***Reset Form
SHEET 1 OF 1
DWG SIZE
B
* Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Switch Housing section (page 48).
*** M20 adapters are brass. Contact the factory for
alternate materials.
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
730 Series
Specific Gravity Ranges
Optional Switching Arrangements
Dual-stage, wide differential switches may be ordered with switching arrangements different from
those shown on page 38. To order, select the desired arrangement below and add SC to the
accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.
Arrangement 1
Arrangement 2
Arrangement 4
Arrangement 5
Arrangement 6
Switch Position
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
39/60
750 Series
Step 1: Model Series
751 A-F7A-B-A3-N1-CRTT
The 750 Series mechanical level switches are three-stage, displacer-operated switches suitable for
top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages
44 - 50 for switching elements, housings and accessories.
Maximum Working Pressure
Model
Series
Minimum
Specific
Gravity
750
0.96
751
0.85
752
0.96
753
0.85
754
0.96
755
0.95
756
0.96
757
0.95
Function
Connection
Style
NPT
Narrow
Differential
Wide
Differential
Connection
Material
100°F
(38°C)
450°F
(232°C)
Porcelain
All
1000
(69)
750
(52)
SS
All
1000
(69)
750
(52)
Flange
Porcelain
Flange
SS
NPT
Pressure Rating - psig (bar)
Displacer
Material
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
Porcelain
All
1000
(69)
750
(52)
SS
All
1000
(69)
750
(52)
Flange
Porcelain
Flange
SS
A105
285
(20)
185
(13)
316SS
275
(20)
182
(13)
A105
285
(20)
185
(13)
316SS
275
(19)
182
(13)
Displacer units are not available over 450oF (232oC).
*An operating specific gravity is required for all 750 series at time of order.
Step 2: Process Connection Material
751 A -F7A-B-A3-N1-CRTT
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.
40/60
Designator
Material
A
A105 Carbon Steel fittings or flanges
C
A182-TP316/316L Stainless Steel fittings or flanges
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
750 Series
Step 3: Process Connection
751A -F7A-B-A3-N1-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Size
Style
2-1/2”
3”
4”
6”
Model
750
751
752
753
754
755
756
757
NPT
F7A
F7A
-
-
F7A
F7A
-
-
NPT
F3A
F3A
-
-
F3A
F3A
-
-
150# RF Flange
-
-
F3C
F3C
-
-
F3C
F3C
300# RF Flange
-
-
F3D
F3D
-
-
F3D
F3D
150# RF Flange
-
-
F4C
F4C
-
-
F4C
F4C
300# RF Flange
-
-
F4D
F4D
-
-
F4D
F4D
150# RF Flange
-
-
F6C
F6C
-
-
F6C
F6C
300# RF Flange
-
-
F6D
F6D
-
-
F6D
F6D
Step 4: Trim Material
751 A -F7A-B-A3-N1-CRTT
Select the internal trim material from the chart below.
Model
Displacer
Material
Attraction
Sleeve
Construction
Material
750
751
752
753
754
755
756
757
316/316L SS
400SS
A only
-
B
-
B
-
B
-
B
316/316L SS
316/316L SS
A or C
-
C
-
C
-
C
-
C
Porcelain
400SS
A only
P
-
P
-
P
-
P
-
Porcelain
316/316L SS
A or C
R
-
R
-
R
-
R
-
Standard displacer spring material is Inconel 600.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
41/60
750 Series
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 750/752
2-1/2” NPT/Flanged
Model 751/753
2-1/2” NPT/Flanged
Model 754/756
2-1/2” NPT/Flanged
Model 755/757
2-1/2” NPT/Flanged
1
SALES PAGE
MODEL #
SALES ORDER #
LINE ITEM #
PURCHASE ORDER #
NPT A
180.9
7.12
180.9
7.12
FLANGE B
101.6
4.00
101.6
4.00
W
W
PROCESS
CONNECTION
NPT A
D
3048
120.0
316 SST
CABLE
PROCESS
CONNECTION
FLANGE B
DIMENSION C
3"
4"
MINIMUM
229
9.0
3048
120.0
316 SST
CABLE
HIGH
SEE CHART
SIZE
C
MINIMUM
229
9.0
SEE CHART
ELECTRICAL CONNECTION W
*306.4
12.06
*306.4
12.06
DIMENSION C
DIMENSION D
6"
FLANGE
150 #
300 #
600 #
62.7
2.47
62.7
2.47
64.3
2.53
67.6
2.66
70.6
2.78
75.4
2.97
70.6
2.78
77.0
3.03
86.6
3.41
DIMENSION D
HIGH
84.9
3.34
87.9
3.46
2-1/2 NPTM
3 NPTM
TOP
SWITCH
ACTUATION
LOW
TOP
SWITCH
ACTUATION
HIGH
316 SST
DISPLACER
MIDDLE
SWITCH
ACTUATION
LOW
HIGH
316 SST
DISPLACER
LOW
63.5
2.50
MODEL 751
SCALE 0.15
Drawing 0390681
Drawing 0390682
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
LOW
DRAWN BY
HIGH
190.5
7.50
BOTTOM
SWITCH
ACTUATION
222.3
OVERHEAD CLEARANCE
8.75
REQUIRED TO REMOVE HOUSING COVER
* MINIMUM
ISO-9001
MIDDLE
SWITCH
ACTUATION
HIGH
LOW
190.5
7.50
BOTTOM
SWITCH
ACTUATION
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
63.5
2.50
MODEL 753
SCALE 0.15
R SAVERINO
DATE
Drawing 0390683
DIMENSION DRAWING 751, 753
NARROW DIFFERENTIAL
Drawing 0390684
EO NUMBER: 5123
SCALE: 0.15
DRAWING NUMBER
REV
0390682
3
SHEET 1 OF 1
DWG SIZE
B
Reset Form
W
1” NPT
** See Switch Housing
section (Page 48).
42/60
ENGINEER APPROVAL
TITLE
* Minimum 8-3/4’’ (222 mm) overhead clearance required to remove housing cover.
B5
N1
N8
J REHM
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
Model Name: 0390682.ASSEM/2/0
Housing**
CHECKED BY
27 JUL 2011
LOW
DO NOT SCALE PRINT
Explosion Proof
General Purpose
Explosion Proof
K MITCHELL
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
750 Series
Specific Gravity Ranges
Optional Switching Arrangements
Three-stage, wide differential switches may be ordered with switching arrangements different
from those shown on page 42. To order, select the desired arrangement below and add SC to
the accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.
Arrangement B
Arrangement C
Arrangement G
Form 912 (01.15) ©SOR Inc.
Arrangement D
Arrangement H
SORInc.com
Arrangement E
Arrangement F
Switch Position
| 913-888-2630 | Registered Quality System to ISO 9001
43/60
Level Switches
Switching Mechanisms
SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a
variety of electrical and pneumatic switching mechanism types to fit a wide range of applications.
The basic types of switch mechanisms available are listed below. See page 47 for specifications.
All SOR switching mechanisms are constructed from stainless steel and other durable
manufactured materials. Each mechanism is individually calibrated and inspected to insure
accuracy and repeatability. See below for the benefits and application of each switch type.
All mechanisms are interchangeable with most competitor units.
Standard Dry-Contact Switches
Types A, B, C, E
Standard dry-contact switches have open mechanisms and
exposed switching elements. These switching mechanisms are
easy to maintain. Visual confirmation of operation is obvious.
Dry-contact switch mechanisms are recommended for most level
switch applications and are available in SPDT and DPDT switch
arrangements.
Dry-Contact Switch Mechanisms feature:
• High-load carrying capacity
• High-quality phenolic insulator
• Vibration resistance
• Versatility of application
Mini-Hermetically Sealed Switches
Types L, S, T, V
Mini-hermetically sealed switches have a hermetically sealed
switch element on an exposed mechanism. Good for hightemperature service and normal applications that require
hermetically sealed contacts.
Mini-Hermetically Sealed Switch Mechanisms feature:
• Rugged stainless steel construction
• Class I Group A rating for use in hazardous areas
• Vibration resistance
• High operating temperature limits
Anti-Vibration Switches
Types D and R
Anti-Vibration Switches employ two magnets to provide
vibration protection. Dual magnets prevent false trips by
providing a positive mechanical lock to the enclosing tube
when the switch is in any position.
(Type T switches are mini-hermetically sealed units with
dual magnets.)
44/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Switching Mechanisms
Pneumatic Switch
Type J
Pneumatic switches are available for applications that prohibit
electrical switching or where electricity is not available.
Pneumatic switches feature:
• Three-way aluminum valve
• Anti-vibration design
• 1/4" NPT ports in 316SS for additional corrosion resistance
Extra-High Temperature Switch
Type Y
The Y Series level switch mechanism is designed to
operate normally under extremely high-temperature
conditions. Constructed of stainless steel, ceramic, and
oxidation-resistant alloys, the Y Series is designed to
counteract the warping and seizure normally associated with
this type of mechanism in high temperatures. The Y Series
switch is especially well suited for power plant conditions.
Y Series Switch Mechanisms feature:
• Mica/glass insulation on wires and switches
• Stainless steel and ceramic switch element
and terminal block
• Switch mechanism rated at 800°F (427°C)
continuous process temperature
• Can be combined with external temperature
protection to function in temperatures up to
1200°F (649°C)
• Dual magnets for vibration protection
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
45/60
Level Switches
Switching Mechanisms
741A -A1C-B-A1-N4-CRTT
Select the switch mechanism from the chart below.
1
Single
A3
B3
C3
A4
B4
C4
A5
B5
C5
A8
B8
C8
-
l
l
l
l
l
l
l
l
l
1
Switch Designator
A1
B1
C1
1
A2
B2
C2
l
l
l
l
l
l
l
Rostechnadzor (RTN)
Triple
INMETRO (IS)
Dual
INMETRO (flameproof)
Standard Dry Contact
High-Temperature Dry Contact
Gold Contact
Single
IECEx
Switching Description
Triple
ATEX (flameproof)
Dual
Available Agency
Listings
UL
Single
3-Way
Valve
CSA
Switching Stages
DPDT
Double Pole
Double Throw
ATEX (IS)
SPDT
Single Pole
Double Throw
Switch Type
l
l
l
l
Anti-Vibration Dry Contact
High-Amperage DC Service
D1
E1
E2
E3
D4
E4
E5
E8
-
l
l
l
l
l
l
l
l
l
l
l
l
Standard Mini-Hermetically Sealed
L1
L2
L3
L4
L5
L8
-
l
l
l
l
l
l
Anti-Vibration Gold Contact1
R11
-
-
R41
-
-
-
l
l
l
l
l
l
l
l
Gold Contact Mini-Hermet
Anti-Vibration Mini-Hermet1
High-Temperature Mini-Hermet
S1
T11
V1
S2
V2
S3
V3
S4
T41
V4
S5
V5
S8
V8
-
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Extra-High Temperature (Ceramic)
Pneumatic Non-Bleed with 316SS
Fittings
Y11
-
-
-
Y41
-
-
-
J01,2
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Available with models:
Series 100-200-300-740-800
Series 108/208-400
Series 700
Series 730
Series 750
(enclosures N1, N8 or B5 only)
l
l
l
l
Notes
1. These switches use two magnets and must be considered dual mechanisms when figuring minimum
specific gravity.
2. Pneumatic switching mechanisms must be specified with P1 housing.
46/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Switch Ratings
210-250VAC
20-30VDC
110-130VDC
210-250VDC
110-130VAC
210-250VAC
20-30VDC
110-130VDC
210-250VDC
Inductive Amperage
110-130VAC
Resistive Amperage
A
Standard Dry Contact
15
15
5
.5
.25
15
15
5
.4
.13
-15°F
(-26°C)
250°F
(121°C)
B
Hi-Temperature Dry
Contact
5
5
1.5
.5
-
5
5
1
.25
-
-15°F
(-26°C)
400°F
(204°C)
C
Gold Contact
1
-
1
-
-
1
-
.5
-
-
-15°F
(-26°C)
250°F
(121°C)
D
Anti-Vibration
15
15
5
.5
.25
15
15
5
.4
.13
-15°F
(-26°C)
250°F
(121°C)
E
High-Amp DC
-
-
10
10
3
-
-
10
10
3
-15°F
(-26°C)
250°F
(121°C)
L5
MiniHermetically
Sealed
DPDT
5
5
5
.5
-
5
5
2.5
.25
-
SPDT
11
11
5
.5
.25
11
11
2.5
.25
.13
-15°F
(-26°C)
250°F
(121°C)
R
Anti-Vibration Gold
Contact
1
-
1
-
-
1
-
.5
-
-
-15°F
(-26°C)
250°F
(121°C)
S
Gold Contact
Mini-Hermet
1
-
1
-
-
1
-
.5
-
-
-15°F
(-26°C)
250°F
(121°C)
T5
Anti-Vibration
Mini-Hermet
5
5
5
.5
-
5
5
2.5
.25
-
-15°F
(-26°C)
250°F
(121°C)
(-26°C)
250°F
(121°C)
V
Y6
Switch Designator
J4
DPDT
Minimum
Temperature1
Maximum
Temperature2
11
11
5
.5
.25
11
11
2.5
.5
.13
-15°F
High-Temperature
Mini-Hermet
5
5
1.5
.5
-
5
5
1
.25
-
-15°F
(-26°C)
400°F
(204°C)
Extra-High Temperature
(Ceramic)
1
1
1
.4
-
1
1
.4
-
-
-40°F
(-40°C)
800°F
(427°C)
5°F
(-15°C)
200°F
(93°C)
SPDT
Pneumatic 316SS
Fittings
Non-bleed 3-way aluminum valve body.
Buna-N O-Rings
150 psi maximum supply, 24CFM @ 100 psi
Note 3
Notes
1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary
according to actual climatic conditions. Actual minimum process temperature may be much lower.
Consult the factory for details.
2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased
according to the type of process. Refer to pages 51 - 52 for more details.
3. -40°F Temperature rating with no icing.
4. Pneumatic switches must be used with clean, dry air or gas.
5. These switch designators have higher current rating for SPDT than DPDT.
6. Manufacturer specifications state maximum operating humidity must be <85% and minimum power rating is 100mW.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
47/60
Level Switches
Housings
741A -A1C-B-A1-N4-CRTT
SOR housings are designed to protect the switching mechanisms from harsh environmental
conditions, as well as protecting the surrounding atmosphere from potential ignition sources. The
basic types of housings are listed below.
General Purpose, NEMA 4 Housings
are heavy duty cast aluminum. All housings are
rated NEMA 4 (IP65) as a minimum.
Explosion-Proof Housings
are available in aluminum or cast iron. Explosion-Proof ratings include
Class I, Group B, C, D; Division 1 & 2, and Ex d IIC T6 Gb (ATEX) and
Ex d IIC T6 (IECEx).
Pneumatic Switch Housings
are required for use with a pneumatic switching mechanism. These
enclosures are General Purpose, NEMA 4 (IP65) only.
NEMA 4X Housings
are standard in aluminum. Cast iron enclosures can be rated NEMA 4X by adding epoxy
coating.
Switch Housings
Select the housings from the chart below.
Available with Models
108, 208, 400
740, 800
700’s
730’s
£
£
£
£
£
£
£
£
B2
Cast Iron
Groups B, C, & D
£
£
£
£
£
£
£
£
B5
Aluminum Extended
Groups B, C, & D
£
£
£
N1
Aluminum Extended
NEMA 4, 4X
£
£
£
N4
Aluminum
NEMA 4, 4X
£
N6
Cast Iron Double Hub
Groups C & D
£
N7
Aluminum
Groups C & D
£
N8
Aluminum Extended
Groups C & D
£
P1
Aluminum Pneumatic
NEMA 4, 4X
S3
Aluminum
Ex d IIC T6 (IECEx)
Ex d IIC T6 Gb (ATEX)
Ex ia IIC T6 Gb (ATEX)
S82
Cast Iron
Ex d IIC T6 (IECEx)
T62
Cast Iron
Ex d IIC T6 Gb(ATEX)
Ex ia IIC T6 Gb (ATEX)
2
2
1
ATEX
Enclosure Rating2
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
n
750’s
100, 200, 300
Groups B, C, & D
B1
Description
INMETRO
UL
Aluminum
Designator
TestSafe
CSA
Rostechnadzor
Agencies
£
n
£
£
n
£
£
£
£
£
£
£
£
£
£
£
£
—
Available
— Standard (Agency listing accessory designator is not needed.)
1. P1 housing must be used with pneumatic switch mechanisms.
2. All cast iron housings can be rated NEMA 4X by adding PY to the accessory section of the model number.

48/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Accessories
741A -A1C-B-A1-N4-CRTT
SOR accessories are provided for customizing the level switches in this
catalog according to the requirements of the application. Place accessory designator(s) from the table below at the
end of the model number. Check the compatibility chart below for correct use of each accessory.
Accessory Compatibility Chart
Model Series
Description
100
200
108/
208
300
400
741-743
802
740
804
700
730
750
AF1
FE
CL
Air Filter & Gauge
Finned Extention
ATEX Approved for S3 Hsg
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
CN7
CP7
CR7
Conduit Reducer M20 x 1.5
Conduit Reducer 1/2” NPT
Conduit Reducer 3/4” NPT
CS2
CV
CY
CSA Certification
Canadian Registration Number (CRN)
Certificate of Conformance
(power plant piping, ANSI 31.1)
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
CZ3
l
l
l
l
l
l
DN
EC8
Certificate of Conformance
(petrochemical piping, ANSI 31.3)
Special Drain Connection
Extra Chamber Connection
l
C/F
l
C/F
C/F
l
C/F
l
C/F
ET5
FE
GG
Temperature Extension
Finned Extention
Sealed Conduit
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
ID
KK
MC4
Interface Detection
Housing Breather Drain
Manual Check
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
MR
MT
NC
NM
Mill Test Report
Mag Particle Examination
NACE Construction
INMETRO Approved for S3 Hsg
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
PP
PT
PY
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
RR
Fiber Tag
Dye Penetration Examination
Powder coat epoxy coating. No coating on
stainless steel parts or plated screws.
(500 hrs. salt spray)
SS Tag wired to housing
l
l
l
l
l
l
l
l
l
l
RT
SC10
SD11
Radiograph Examination
Special Calibration
Special Dimensions
l
C/F
C/F
l
C/F
C/F
l
C/F
C/F
C/F
l
C/F
l
C/F
C/F
l
C/F
C/F
C/F
C/F
C/F
SL12
TC4
Special Cable Length
Tru-Check
l
l
l
l
l
TF
TT
Tandem Floats
Oversized Nameplate for customer tagging
C/F
l
C/F
l
l
UT
VV
WC
WV2
Ultrasonic Examination
Fungicidal Varnish
Water Column Unit
UL Listed
l
l
C/F
l
l
l
YY
Epoxy Coating (enclosure only)
l
9
Notes
1.
2.
3.
4.
5.
C/F = Consult the Factory
Pneumatic switching mechanisms only (P1)
Consult switch and housing sections for agency availability.
Process media must be known prior to manufacture. Different processes (service categories) require different quality
inspection procedures. Consult the factory for details.
Appropriate for Model Series 701 through 704 and 730
through 733. See page 55 for details. Not available with NACE.
See high-temperature selection for application.
Form 912 (01.15) ©SOR Inc.
SORInc.com
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
6. Not available with agency-listed housings.
7. Not available with T6 and S3 (ATEX) housings.
8. Need connection size, type, and location on chamber.
9. The upper and lower specific gravity required to determine functionality.
10. Operating specific gravity, Set Point (referenced from upper process connection) and if Set Point is rising or falling are required.
11. Specific details of chamber dimensional changes.
12. Length of cable required (10 ft. is standard).
| 913-888-2630 | Registered Quality System to ISO 9001
49/60
Level Switches
Test Certificates
Float Operated Switches
Certificates
C1
Series 100
Calibration
¿
Series 200
Hydrostatic
Pressure Test
Series 220
Inspection
Report
Series 300
Compliance /
Conformance
Series 400
Series
108/208
C2
C3
C4
C5
C6
C7
¿
¿
B2
B3
B5
B6
B7
A2
A3
A4
A7
A8
A9
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
¿
Dielectric Test
¿
¿
¿
¿
Insulation
Resistance
¿
¿
¿
¿
¿
¿
¿
QA Test Report
¿
¿
¿
¿
¿
¿
¿
Displacer Operated Switches
Series 700, 730, 750
Certificates
C1
Calibration
¿
Inspection Report
C3
C4
C5
C6
C7
¿
*Series 740
Compliance / Conformance
*Series 800
Dielectric Test
B5
B6
B7
¿
¿
¿
¿
¿
¿
¿
¿
¿
Insulation Resistance
QA Test Report
¿
¿
¿
¿
¿
*These products also have Certificate C2 - Hydrostatic Pressure Test.
50/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
High Temperature Selection
SOR level switches can accommodate high-temperature applications up to 1200oF (649oC).
These temperatures may be safely reached by a proper combination of chamber material, switch
mechanism and temperature extension. Refer to page 52 to select the proper components for your
process temperature.
DRAWING NUMBER
03
ET Accessory
MODEL #
PURCHASE ORDER #
The straight temperature extension provides physical distance
between the process and the switching mechanism. It is
constructed of a straight piece of pipe welded between the
chamber and enclosing tube connection.
SALES ORDER #
201 A -A1C-B-A1-N4-ET TT
146.1
O
5.75
REQUIRED TO REM
* MINIMUM
180.9
7.12
101.6
4.00
How It Works
The straight temperature extension is designed to remove the
switch from direct radiant heat in dry heat processes. Consult
the chart on page 52 for application.
*228.6
9.00
SWITCH
ENCLOSURE
14685 W
To Specify
Add Accessory Designator ET to the end of the SOR level
switch model number per the selection chart on the next page.
ISO-9001
W
TEMPERATURE
EXTENSION
The ET accessory automatically matches the material and
rating of the specified level switch chamber. This option can
be supplied on SOR level switches Series 100, 200, 300
and 400.
LINEAR =
THIS DRAWING IS T
NO USE WHATSOEVER
HEREON, NOR REPROD
MADE WITHOUT THE EX
CHAMBER/PROCESS
CONNECTION
Drawing 0390676
FE Accessories
PRODUCT CERTIFICA
ALL DIMENSIONS
UNLESS OTHERWI
TITLE
DIM DWG STRAIGHT TE
EO NUMBER: 5090
SCALE: DRAWING SCAL
DO NOT SCALE PRINT
Model Name: MODEL NAME.DRAFT/2/1+
201 A -A1C-B-A1-N4-FE TT
The finned temperature extension is designed to protect the electrical portion of a level switch
from heat damage due to condensing processes. When used in combination with high-temperature switch
mechanisms, this option allows operation in process temperatures up to 1200oF (649oC).
How It Works
The finned temperature extension condenses process steam and
reduces its heat before it can reach the switching mechanism.
The design reduces steam to its saturation temperature in the
enclosing tube, protecting the switching mechanism from
deterioration due to high temperatures. The process
pressure dictates the saturation temperature, see page 57.
To Specify
Add Accessory Designator FE to the end of the SOR
level switch model number per the selection chart on the
next page.
The finned temp. extension automatically matches the material
and rating of the specified level switch chamber. These options
can be supplied on SOR level switches series 100, 200,108/208,
300 and 400.
Note: For proper cooling, temp. extensions must not be insulated
or placed inside an enclosed structure. High ambient temperatures
(over 100oF/38oC), intense direct sunlight, or heat loading from
adjacent piping or vessels will affect cooling performance.
Consult the factory if any of these conditions exist.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
51/60
Level Switches
High Temperature Selection
There are two sections to the chart, Steam Heat and Dry Heat. Fundamental differences in condensing
(steam) and non-condensing (dry) heat require different methods of protection.
Steam Heat processes carry it’s heat with the vapor. These processes effectively heat every portion of their
enclosure. To reduce the heat effects of condensing processes, we must either condense or physically block
the vapor. SOR uses a condensing system to avoid the sealing problems associated with blocking the steam.
Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where they
touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may be resolved by
adding distance between the process and the protected portion of the control.
To use the selection chart, first select the column that represents the desired maximum temperature. Select
a chamber material that is allowable in the chosen column. Move down to the proper process type section,
Steam Heat or Dry Heat. Within that section, select a switch mechanism from those listed in the chosen
column. The symbol will indicate if a temperature reduction device is required.
­
­­­­­­­­­­
≤ 1200oF (649 oC)
­
­­­­­­­­­­
≤ 1150oF (621oC)
­
­­­­­­­­­­
≤ 1100oF (593oC)
­­­­­­­­­­­
≤ 1050oF (566oC)
­
­­­­­­­­­­­
≤ 1000oF (538oC)
­
­­­­­­­­­­­
≤ 950oF (510oC)
≤ 700oF (371oC)
­
­­­­­­­­­­­
≤ 900oF (482oC)
≤ 650oF (343oC)
­
­­­­­­­­­­­
≤ 850oF (454oC)
≤ 600oF(316oC)
­
­­­­­­­­­­­
≤ 800oF (427oC)
≤ 550oF (288oC)
­
­­­­­­­­­­­
≤ 750oF (399oC)
≤ 500oF (260oC)
A106B Carbon Steel
304/304LSS
316/316LSS
≤ 450oF (232oC)
Chamber Material (Select one)
0-400oF (204oC)
Features
Designator
High Temperature Selection Chart
A
C
A333 GR.6
A335-P11 Chrome Moly
A335-P91
Hastelloy C
Alloy-20
Monel-400
­
­
­­­­­­­­­­­­
­­­­­­­­­­­
­
­­­­­­­­­­­
­
­­­­­­­­­­­
­
­­­­­­­­­­­
­
­
­­­­­­­­­­­
­­­­­­­­­­­­
­
­­­­­­­­­­­
­­­­­­­­­­
n
n
v
v
v
v
n
n
l
l
l
l
­
­­­­­­­­­­­­
­­­­­­­­­­­
Steam Heat Applications
Switch Mechanism (Select one)
Hi-Temp Dry Contact
or Mini-Hermet
Hi-Temperature Ceramic/SS
B/V
n
l
l
v
v
Y
n
n
n
n
n
n
n
v
v
v
v
Dry Heat Applications
Switch Mechanism (Select one)
Hi-Temp Mini-Hermet
or Dry Contact
Hi-Temperature Ceramic/SS
B/V
n
l
l
l
l
Y
n
n
n
n
n
n
n
For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed structure. High ambient temperatures (over 100ºF/38ºC), intense direct sunlight or heat loading from adjacent piping or vessels will affect cooling
performance. Consult the factory if any of these conditions exist.
n = Switch Only
52/60
v = Finned Extension
Registered Quality System to ISO 9001
l = Temperature Extension
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
High Temperature Selection
Model
Material
500°F
(260°C)
550°F
(288°C)
600°F
(316°C)
650°F
(343°C)
700°F
(371°C)
750°F
(399°C)
101
CS & SS
170
155
140
125
110
95
102
CS & SS
447
435
423
411
400
389
103
CS
SS
600
480
575
465
550
450
535
445
535
430
505
425
104
CS & SS
894
870
846
823
800
778
108
CS
SS
600
480
575
465
550
450
535
445
535
430
505
425
109
CS & SS
170
155
140
125
110
95
121
CS & SS
170
155
140
125
110
95
122
CS & SS
313
304
296
288
280
272
201
CS & SS
201
196
190
185
180
175
202
CS & SS
268
261
254
247
240
233
203
CS & SS
447
435
423
411
400
389
204
CS & SS
1118
1087
1057
1029
1000
972
205
CS & SS
671
652
634
617
600
584
206
CS & SS
894
870
846
823
800
778
207
CS & SS
894
870
846
823
800
778
208
CS
SS
1794
1495
1794
1453
1794
1411
1794
1387
1722
1351
1554
1339
209
CS & SS
403
391
381
370
360
350
221
CS & SS
313
304
296
288
280
272
Form 912 (01.15) ©SOR Inc.
SORInc.com
Higher temperatures available with other materials.
Consult with the factory.
Float Switch Pressure Ratings (in psi) above 450°F (232°C)
| 913-888-2630 | Registered Quality System to ISO 9001
53/60
Examination and Testing
Requirements
741A -A1C-B-A1-CYCRTT
Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance.
Designator
Certificate of Conformance to
CY
ASME/ANSI B31.1 Power Piping
CZ
ASME/ANSI B31.3 Petrochemical Piping
If certification to B31.3 is required, SOR, Inc. must know the fluid category per the chart below. Read the
ASME/ANSI B31.3 Fluid Category Section at the bottom of this page to determine the applicable category.
Units Covered
Visual
Examination1
Radiographic
(X-Ray) RT
Magnetic
Particle MT
Dye
Penetrant PT
Hydrotest
0%
1.5 x pressure
for 3 minutes
Standard Inspection
All Chambers
100%
0%
0%
CY Option (ASME/ANSI B31.1)
Below 750°F
Below 1025 psi
100%
-
-
-
Below 350°F
All pressures
100%
-
-
-
350°F - 750°F
Above 1025 psi
100%
All butt welds >2”
-
-
Above 750°F
All pressures
100%
All butt welds >2”
Butt welds >2”
all other welds
Butt welds >2”
all other welds
CZ Option (ASME/ANSI B31.3)
5%2
-
1.5 x pressure
for 10 minutes
Normal Fluid
5%
-
Category D
Engineering/QA
Choice
-
-
-
Category M
100%
20% of all welds3
-
-
Severe Cyclic
100% in place
of RT
100% of all
butt welds+
MT of welds
excluded @ RT
MT of welds
excluded @ RT
High Pressure
100%
100% of girth/
branch welds
-
-
1.5 x pressure
for 10 minutes
Notes
1. In process visual inspection: inspecting pipe bevel prior to welding, check fit-up, check after-tack weld, and
check during weld passes. After completion visual inspection: welding and grinding is checked.
2. In process examination may be substituted on a weld-for-weld basis.
3. In process examination supplemented by appropriate NDE (MT or PT) may be substituted on a
weld-for-weld basis.
ANSI/ASME B31.3 Fluid Category
Normal
A fluid service not subject to the following four categories.
Category D
A fluid service in which all of the following apply:
1. The fluid handled is non-flammable, non-toxic, and not damaging to human skin.
2. The design gage pressure does not exceed 150 psi.
3. The design temperature is between -20°F and 366°F.
Category M
A fluid service in which the potential for personnel exposure is judged to be significant and in which a single exposure to a very small quantity of a toxic fluid, caused by leakage, can
produce serious irreversible harm to persons on breathing or bodily contact, even when prompt restorative measures are taken.
Severe Cyclic A fluid service with high-cycle rates that cause extreme stress on components.
High Pressure Pressure in excess of that allowed by the ASME B16.5 Class 2500 rating for the specified temperature and material group or any piping so designated by the customer.
54/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
MC and TC Options
702A-AIC-B-A1-MC-CRTT
Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level
switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel
chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top
of the tank. Specify either an MC or TC option by placing the designator in the accessory section of
the model number.
Designator
Application
TC
Tanks or vessels pressurized to 100 psi
MC
Atmospheric vented tanks or vessels
These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and
TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high
and low SG values. Please consult factory before ordering the MC or TC options for these models.
How It Works
Pulling the handle transfers downward motion to the actuator lever by means of the beaded
stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves
the attraction sleeve and actuates the switching element to simulate a high-level condition.
Switching action for alarm, shutdown or control is verified.
Dimensions
SALES ORDER #
101.6
4.00
LINE ITEM #
PURCHASE ORDER #
Product Specifications
393.7
15.50
Pressure Range
W
TC (Tru-Check)
MC (Manual Check) 0 psi (vented to atmosphere)
*0 to 100 psi
*Maximum pressure for entire level sensing assembly
*456.4
17.97
is 100 psi with Tru-Check installed.
229.4
9.03
Temperature Range -40 to 300°F (–40 to 150°C)
Wetted Parts
PROCESS
CONNECTION
2-1/2 NPTM OR
4" 150# FLANGE
(NOT SHOWN)
Ball
Chrome Plated Brass
Seal
Spring
Body
Teflon
Spring Steel
146.1
OVERHEAD CLEARANCE
5.75
1018COVER
Steel
REQUIRED TO REMOVE HOUSING
* MINIMUM
ELECTRICAL
Design and specifications are subject
to change
CONNECTION
"W" without notice.
For latest revision, see www.sorinc.com.
14685 W 105TH ST LENEXA, KS 66215 USA
CUSTOMER
SPECIFIED
DIMENSION
316 SST
CABLE
ISO-9001
HANDLE
913-888-2630
SORINC.COM
DRAWN BY
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
J FIFE
DATE
16 MAY 2011
DISPLACER
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 700 SERIES W/MANUAL CHECK
EO NUMBER: 5116
Drawing 0390674
SCALE: 0.20
DO NOT SCALE PRINT
74.ASSEM/1/5+
DRAWING NUMBER
REV
0390674
3
SHEET 1 OF 1
DWG SIZE
B
Reset Form
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
55/60
Level Switches
ASTM Material Designations
SOR uses all ASTM grade materials in the construction of mechanical level switches. The following chart
lists the specific ASTM (or UNS) materials that are normally used for each component in our switches.
Consult the factory if you do not see the specific material required for your application.
ANSI B36.10
ANSI B16.9
ANSI B36.10
ANSI B16.5
Seamless
Pipe
Butt Weld
Fitting
Screwed/Socket
Fitting
Flanges
Temperature
Range
Carbon Steel
A106B
A234-WPB
A105
A105
-20°F to 800°F
304/304LSS
A312-T304
A403-WP304
A182-F304
A182-F304
-425°F to 750°F
A312-T316
A403-WP316
A182-F316
A182-F316
-325°F to 750°F
Low Temperature
Carbon Steel
A333 Gr. 6
A420-WPL6
A350-LF2
A350-LF2
-50°F to 700°F
1-1/4% Chrome2
1/2% Moly
A335-P11
A234-WPL11
A182-F11
A182-F11
-20°F to 1100°F
Hastelloy-C2762
N10276
B6221
B366/B564
B366/B564
B366/B564
-325°F to 800°F
Alloy-202
N08020
B4641
B366/B962
B366/B462
B366/B462
-325°F to 800°F
Monel 4002
N04400
B-1651
B366/B564
B366/B564
B366/B564
-325°F to 900°F
A-790
A-815
A182-F51
A182-F51
-60°F to 600°F
2-1/4% Chrome
1% Moly
A335-P22
A335-P22
A182-F22
A182-F22
-20°F to 1100°F
9% Chrome
1% Moly
Vanadium
A335-P91
A234-WP91
A182-F91
A182-F91
-20°F to 1200°F
Material
2
316/316LSS
2
Duplex SS2
2
Notes
1. UNS numbers are given in parenthesis for special alloys.
2. These materials are available by special order only.
Flange Face Finishes
The most common flange face finishes are shown. SOR standard flange finishes are
highlighted.
Raised Face Flanges (RF)
All raised-face flange finishes are given as a range. AARH (Average Arithmetic Root Height) values are
given with their metric equivalent.
AARH (µin.)
1000-2000
500-1000
250-500
125-250
63-125
32-63
16-32
Ra (µm)
25-50
12.5-25
6.3-12.5
3.2-6.3
1.6-3.2
0.8-1.6
0.4-0.8
Ring Tight Joint Flanges (RTJ)
The side surfaces of RTJ gasket surfaces shall not exceed 63µ” (1.6µm) roughness per ANSI B16.5.
56/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Specific Gravity of Water
The specific gravity of water changes depending on its temperature and pressure. The chart below
lists properties of saturated steam. Saturated steam is the state where water is in transition between
liquid and vapor. The chart provides the process temperature with the associated pressure and specific gravity of the condensate water. If a water application has a high temperature and low pressure,
condensate will only be present at the temperature that corresponds to the maximum pressure.
Select the proper row based on the temperature and pressure, and read the specific gravity.
Figures are based on saturated steam.
Boiling
Temperature
F°
Vacuum
Inches Hg
Specific
Gravity
Boiling
Temperature
F°
Pressure
psig
Specific
Gravity
Boiling
Temperature
F°
Pressure
psig
Specific
Gravity
32
29.74
.9999
212
0.0
.96
450
407.0
.82
40
29.67
1.0000
220
2.49
.96
460
451.2
.81
50
29.56
.9997
230
6.08
.95
470
498.8
.80
60
29.40
.9990
240
10.27
.95
480
550.1
.80
70
29.18
.9980
250
15.13
.94
490
605.2
.79
80
28.89
.9966
260
20.14
.94
500
664.3
.78
90
28.50
.9950
270
27.17
.93
510
728.3
.77
100
27.99
.9931
280
34.52
.93
520
795.3
.76
110
27.33
.9909
290
42.87
.92
530
868.3
.76
.9886
300
52.30
.92
540
945.3
.74
63.00
.91
550
1028.3
.73
120
26.48
130
25.40
.9860
310
140
24.04
.9832
320
75.00
.91
560
1116.3
.71
150
22.35
.9803
330
89.3
.91
570
1209.3
.70
160
20.27
.9772
340
103.3
.90
580
1308.3
.69
170
17.72
.9730
350
119.9
.89
590
1414.3
.68
180
14.63
.9704
360
138.3
.88
600
1529.3
.67
190
10.91
.9668
370
158.5
.88
610
1644.3
.66
200
6.46
.9631
380
180.9
.87
620
1769.3
.65
210
1.17
.9592
390
205.4
.86
630
1902.3
.63
400
232.3
.86
640
2042.3
.62
410
261.6
.85
650
2190.3
.60
Form 912 (01.15) ©SOR Inc.
420
293.4
.84
660
2346.3
.58
430
328.4
.84
670
2511.3
.56
440
366.2
.83
680
2690
.49
690
2883
.48
700
3075
.44
705
3189
.32
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
57/60
Level Switches
Conversions
General English-to-Metric unit conversions are listed below.
Pressure
To Convert from:
Bar
Kilo Pascals (kPa)
Mega Pascals (MPa)
Kilograms per cm2 (kg/cm2)
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Specific Gravity
To Convert from:
Kilograms per meter3 (kg/m3)
Pounds per foot3 (lb/ft3)
Degrees API
Specific Gravity (SG)
Specific Gravity (SG)
Specific Gravity (SG)
Length
To Convert from:
millimeters (mm)
meters (m)
Inches (in.)
Feet (ft.)
Temperature
To Convert from:
Degrees Fahrenheit (°F)
Degrees Centigrade (°C)
Fluid Flow Rates
To Convert from:
Feet per Second (FPS)
Kilograms per Hour (kg/H)
Meters per Second (m/s)
Cubic meters per Hour (m3/hr)
Gallons per Minute (GPM)
Gallons per Minute (GPM)
Gallons per Minute (GPM)
Gallons per Minute (GPM)
To:
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Pounds per Square Inch (psi)
Bar
Kilo Pascals (kPa)
Mega Pascals (MPa)
Kilograms per cm2 (kg/cm2)
Use this formula:
bar
x 14.504 kPa
x 0.145
MPa x 145
kg/cm2 x 14.223 psi ÷ 14.504 psi ÷ 0.145
psi ÷ 145
psi ÷ 14.223
To:
Specific Gravity (SG)
Specific Gravity (SG)
Specific Gravity (SG)
Kilograms per meter3 (kg/m3)
Pounds per foot3 (lb/ft3)
Degrees API
Use this formula:
kg/m3 x 0.001
= SG
lb/ft3
÷ 62.4
= SG
141.5 ÷ (API +131.5)= SG
SG x 1000
= kg/m3
SG
x 62.4 = lb/ft3
(141.5 ÷ SG) - 131.5
= API
To:
Inches (in.)
Feet (ft.)
millimeters (mm)
meters (m)
Use this formula:
mm
÷ 25.4
m
x 3.281
in.
x 25.4
ft.
÷ 3.281
= in.
= ft.
= mm
=m
To:
Degrees Centigrade (°C)
Degrees Fahrenheit (°F)
Use this formula:
(°F - 32) ÷ 1.8
(1.8 x °C) + 32
= °C
= °F
To:
Gallons per Minute (GPM)
Gallons per Minute (GPM)
Gallons per Minute (GPM)
Gallons per Minute (GPM)
Feet per Second (FPS)
Kilograms per Hour (kg/H)
Meters per Second (m/s)
Cubic meters per Hour (m3/hr)
Use this formula:
FPS x 448.83 x A1
(kg/H ÷ kg/m3) x 4.403
m/s x A2 x 15,852
m3/hr ÷ 0.2271
GPM ÷ (448.83 x A1)
GPM x kg/m3 ÷ 4.403
GPM ÷ (A2 x 15,852)
GPM ÷ 4.4 = GPM
= GPM
= GPM
= GPM
= FPS
= kg/H
= m/s
= m3/hr
= psi
= psi
= psi
= psi
= bar
= kPa
= MPa
= kg/cm2
Variables:
A1= Area of pipe in square feet (ft2)
A2= Area of pipe in square meters (m2)
kg/m3 = Specific gravity in kilograms/cubic meter
58/60
Registered Quality System to ISO 9001
| 913-888-2630 | SORInc.com
Form 912 (01.15) ©SOR Inc.
Level Switches
Weights
The approximate shipping weights shown below are for standard models. Weights will vary based
on pipe size, length and flange size. Consult the factory for the weight of a specific unit.
Floats
Displacers
Model
pounds
kilograms
Page
Model
pounds
kilograms
Page
101*
102*
103*
55
80
130
25
37
60
12
12
12
701
702
703
18
18
30
8.5
8.5
13.5
36
36
36
108
109*
121*
130
125
40
59
53
18
21
12
12
704
705
706
30
20
30
13.5
9
9
36
36
36
122*
123*
124*
50
80
90
23
36
42
12
12
12
707
708
730
32
32
20
14.5
14.5
9
36
36
39
201*
202*
203*
45
26
26
20.5
12
12
17
17
17
731
732
733
20
32
32
9
14.5
14.5
39
39
39
204*
205*
206*
26
45
45
12
20.5
20.5
17
17
17
734
735
736
22
22
34
10
10
15.5
39
39
39
207*
208
209*
45
89
62
20.5
22
29
17
17
17
737
740*
741*
34
28
48
15.5
12.5
22
39
33
29
221*
301
303
22
12
12
10
5.5
5.5
17
23
23
742*
743*
750
60
68
24
27
31
11
29
29
43
304
401
402
12
15
12
5.5
7
5.5
23
26
26
751
752
753
24
36
36
11
16
16
43
43
43
403
404
405
28
15
12
12.5
7
19
26
26
26
754
755
756
26
26
38
12
12
17
43
43
43
406
70
32
26
757
802
804
38
185
50
17
82
22.5
43
29
33
*Add weights from the table below to the base model weight for VV, VVT, or VH configurations
with flanges.
VV, VVT and VH Additional Weights
Size
150#
300#
600#
pounds
kilograms
pounds
kilograms
pounds
kilograms
1”
5
2.5
8
4
9
4.5
1-1/2”
8
4
15
7
15
7
2”
12
5.5
16
7.5
18
8.5
Weights shown in this table include two flanges, pipe nipples, and fittings.
Note: Consult the factory for additional weight due to accessories or non-standard requirements.
Form 912 (01.15) ©SOR Inc.
SORInc.com
| 913-888-2630 | Registered Quality System to ISO 9001
59/60
SOR Inc. | Lenexa, KS USA | 913-888-2630 | Fax 913-888-0767 | SORInc.com
REGIONAL OFFICES
China
Middle East
SOR China | Beijing, China
SOR Measurement & Control Equipment Trading JLT | Dubai, UAE
+86 (10) 5820 8767 | Fax +86 (10) 58 20 8770
60/60
Registered Quality System to ISO 9001
+971 4 3699042 | Fax +971 4 3698989