SEE MORE AT SORInc.com Request Quote Level Switches SOR® mechanical level switches are rugged, industrial products specifically designed for versatility of application. This catalog contains application and ordering data for float and displacer-operated level switches. Switches are available with flanged or sealed chambers or as insertion models. 200 Series Options available for each type of switch include: switch type and number, housing type, chamber material, process connections, accessories, and more. Units may be customized to suit customers’ needs. Inside this catalog you will find solutions to your level sensing puzzles. SOR mechanical level switches have many configurations available. If you don’t see what you need, we will engineer a solution for your application. 100 Series Features and Benefits 700 Series • Five-year warranty • Worldwide listings and certifications • ASME Section IX and AWS qualified welding system • Quick worldwide delivery • Designed to ANSI/ASME B31.1 and B31.3 guidelines • Only ASTM grade materials with certified mill test reports used •Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC • Hermetically sealed switching 61508 for non-redundant use in mechanisms available SIL1 and SIL2 Safety Instrumented • Stainless steel switching mechanisms Systems for most models. For more • High-temperature capability details or values applicable to a • Wide variety of explosion-proof housings specific product, see the Safety Integrity Level Quick Guide • Versatile switching mechanisms which retro-fit into other manufacturers’ units (Form 1528). Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 1/60 Level Switches 700 Series Top Mounted Displacer 200 Series Sealed Chamber Float 100 Series Flanged Chamber Float 300 Top Mounted Float 208 Steam Trap Float 400 Series Side Mounted Float 2/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Section Table of Contents Page Principles...........................................................................................................4 Features and Benefits...................................................................................6 How to Order....................................................................................................8 Float Switches 100 Series Flanged External Cage................................................... 9 200 Series Sealed External Cage................................................... 14 108/208 Series Steam Condensate External Cage.................. 18 300 Series Top Insertion Mount...................................................... 20 400 Series Side Insertion Mount.................................................... 23 Displacer Switches Models 741-743, and 802 Flanged External Cage..................... 26 Models 740 and 804 Sealed External Cage................................ 30 700 Series Single-Stage Top Insertion Mount............................. 33 730 Series Dual-Stage Top Insertion Mount................................ 36 750 Series Triple-Stage Top Insertion Mount.............................. 40 Switching Mechanisms.............................................................................. 44 Switch Ratings ............................................................................................. 47 Housings......................................................................................................... 48 Accessories Compatibility Chart............................................................................. 49 Test Certificates................................................................................... 50 High Temperature Selection............................................................. 51 CY and CZ Option Inspection Requirements.............................. 55 MC and TC Options........................................................................... 56 ASTM Material Designations............................................................ 57 Reference Charts Specific Gravity of Water.................................................................. 58 Conversions......................................................................................... 59 Weights................................................................................................. 60 Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 3/60 Level Switches Principles Float-Operated Level Switches Model Series 100, 200 and 300 The float rides on the process liquid surface, precisely tracking liquid surface motion. Switching Element Common Rising liquid level lifts the float, sliding the attraction sleeve up inside the enclosing tube and into the magnetic field to actuate the electrical or pneumatic switch (signaling liquid presence). Normally Open Normally Closed Pivot Bias Spring Subsequently, falling liquid level lowers the float, drawing the attraction sleeve out of the magnetic field to deactuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are generally able to handle high-temperature applications, and sometimes prove useful for close interface detection. Floats can operate up to three switching elements. Independent switching levels may be obtained with tandem floats. Consult the factory for special floatswitching arrangements. Magnet Attraction Sleeve Enclosing Tube Float Level Differential Actuated Deactuated Float-Operated Level Switches Model Series 108/208 and 400 The float rides on the process liquid surface, precisely tracking liquid surface motion. Rising liquid level lifts the float via a pivot mechanism, sliding the attraction sleeve down inside the enclosing tube and out of the magnetic field to deactuate the electrical or pneumatic switch (signaling liquid presence). Subsequently, falling liquid level lowers the float, drawing the attraction sleeve into the magnetic field to actuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are generally able to handle high-temperature applications. Switching Element Actuated Switching Element Deactuated C Common NC Normally Closed Magnetic Field Engaged NO Normally Open Attraction Sleeve Up Bias Spring Enclosing Tube C Common NC Normally Closed Magnetic Field Disengaged NO Normally Open Bias Spring Enclosing Tube Attraction Sleeve Down Counterweight Level Differential Actuated 4/60 Registered Quality System to ISO 9001 Deactuated | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Principles Displacer-Operated Level Switches Model Series 700, 730, 740, 750 and 800 Displacer controls offer alternative features to the float-operated control. The sensor is a weight (displacer), heavier than the liquid, that is suspended by a spring. When liquid contacts the displacer, a buoyancy force is produced, which causes the effective weight of the displacer to change. This causes the spring to retract slightly to a new equilibrium position. When the spring retracts, the attraction sleeve also moves upward into the field of the external magnet, thus overcoming the force of the bias spring and actuating the switching element. This principle provides for narrow or wide switching differential, and allows switching point alteration by moving the displacer(s) up or down the suspension cables. Displacers may be arranged in combinations of narrow and wide differential to operate up to three switching stages. Displacer controls operate under higher pressure conditions than float-operated switches. Form 912 (01.15) ©SOR Inc. SORInc.com Switching Element Common Normally Open Normally Closed Pivot Bias Spring Magnet Attraction Sleeve Enclosing Tube Extension Spring Suspension Rod / Cable Displacer Level Differential Actuated Deactuated | 913-888-2630 | Registered Quality System to ISO 9001 5/60 Features and Benefits Level Switches Features and Benefits General Rugged carbon steel or stainless steel construction Five-year manufacturer’s warranty Quick, worldwide delivery All ASTM materials (see page 56) Quality management system is registered to ISO-9001:2008 Safety Certified to IEC 61508 (SIL) Standard Chamber Materials All SOR level switch chambers are constructed using ASTM grade materials with full material certification. Mill Test Reports are kept on file for all raw materials. Copies are available upon request at the time of order placement. Carbon Steel Construction Chamber Center Section Flanges/Weld Fittings Weld Cap Studs/Nuts A106 Grade B A105 A234-WPB A193-B7/A194-2H Stainless Steel Construction Chamber Center Section Flanges/Weld Fittings Weld Cap Studs/Nuts A312-TP316/316L A182-316/316L A403-316/316L A193-B7/A194-2H Gaskets All standard models are provided with a Nitrile binder composite gasket that is selected for its resistance to hydrocarbons and steam. For high-temperature, high-pressure or NACE-constructed units, a spiral-wound gasket is used with 316SS wound-around Grafoil. Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber head flange. Internal Trim All sensing elements (floats and displacers) are constructed of either 316/316LSS or porcelain as a minimum. Attraction sleeves are available in 400SS as a standard, with 316/316LSS or other exotic metals as an option. All other wetted internal parts are 316SS or better. Displacer springs are made of Inconel 600. 6/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Features and Benefits Level Switches Features and Benefits Switching Mechanisms SOR switching mechanisms are designed for use in punishing industrial conditions. All stainless steel construction - no aluminum or brass. Temperature ratings available from -65°F (–54°C) to 1000°F (538°C) on dry, non–condensing services. Condensing service (steam) temperature ratings available up to 800°F (427°C), and up to 1200°F (649°C) with protection (see page 52). Available switching mechanisms include hermetically sealed, standard open contacts, or pneumatic contacts. Agency listings are available on most switch mechanisms: UL, CSA, ATEX or IECEx. Switch Housings All SOR switch housings are made from rugged castings. Materials are copper-free aluminum or cast iron. A wide range of explosion-proof ratings and agency listings are available. Quality Assurance SOR maintains a high level of quality throughout our corporation. Many quality assurance features are built into our products. ISO 9001 certified engineering design and production system (certified since 1993). Level-welded chambers designed to the guidelines of ASME B31.1 and B31.3 (inspection certificate available – see page 54). All welders and weld procedures are qualified and maintained to ASME Section IX. All ASTM grade materials used - Certified Mill Test Reports required on all raw materials. Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528). Product Support SOR has a full-time engineering staff dedicated to solving your mechanical level switch problems. Engineers and technicians are knowledgeable about sales and production techniques, and are dedicated to providing the best solution to our customers at the best price. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 7/60 Level Switches How to Order Model Number System 101 A-A1C-B-A1-N4-CRTT Model Series Chamber Material Internal Trim Material Process Connection Switch Mechanism Housing Accessories The level switch model number is divided into seven sections that individually specify the components of an SOR level switch. This diagram illustrates the model number arrangement. Select the component designators from the appropriate pages of this brochure. Standard components and ratings are highlighted throughout the brochure for ease of use. Each section includes a valid model number at the top of each listing of component designators. The position of the designator listed below it will be shown in color for reference. How to Order Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator. Step 1: Select Model Series based on maximum working pressure and minimum specific gravity. Step 2: Select Chamber Material. Step 3: Select Process Connection. Step 4: Select Trim Material. Step 5: Select Switch Mechanism & Housing. (Pages 44 through 48). Step 6: Select Accessories as required for service. (Page 49). Page Numbers for Selected Steps 741-743, 802 Series 740 and 804 Series 23 26 30 33 36 40 20 23 26 30 33 36 40 21 24 27 31 34 37 41 Step 100 Series 200 Series 108/208 Series 300 400 Series Series 1 9 14 18 20 2 10 15 18 3 10 15 18 700 730 Series Series 750 Series 4 10 15 18 21 24 27 31 34 37 41 5 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 6 49 49 49 49 49 49 49 49 49 49 Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com. 8/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 100 Series Step 1: Model Series 101 A-A1C-B-A1-N4-CRTT The 100 Series mechanical liquid level switch is float operated with a flanged, serviceable external chamber. Select the sensing unit from the following charts. Then refer to pages 44 through 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Maximum Working Pressure See page 53 for pressure ratings at higher temperatures. Pressure at Listed Temperature in psid (bar)* Model Series Chamber Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) 101 A106B 316SS 285 275 (19.7) (18.9) 260 235 (17.9) (16.2) 230 215 (15.9) (14.8) 215 205 (14.8) (14.1) 200 195 (13.8) (13.4) 185 182 (12.8) (12.6) 102 A106B 316SS 500 500 (34.5) (34.5) 500 500 (34.5) (34.5) 500 500 (34.5) (34.5) 486 486 (33.5) (33.5) 473 473 (32.6) (32.6) 460 460 (31.7) (31.7) 103 A106B 316SS 740 720 (51.0) (49.7) 675 620 (46.6) (42.8) 655 560 (45.2) (38.6) 645 537 (44.5) (37.0) 635 515 (43.8) (35.5) 622 497 (42.9) (34.3) 104 A106B 316SS 990 1000 (68.2) (69.0) 900 1000 (62.0) (69.0) 875 1000 (60.3) (69.0) 860 973 (59.2) (67.1) 845 946 (58.2) (65.2) 822 920 (56.6) (63.4) 109 A106B 316SS 285 275 (19.7) (18.9) 260 235 (17.9) (16.2) 230 215 (15.9) (14.8) 215 205 (14.8) (14.1) 200 195 (13.8) (13.4) 185 182 (12.8) (12.6) 121 A106B 316SS 285 275 (19.7) (18.9) 260 235 (17.9) (16.2) 230 215 (15.9) (14.8) 215 205 (14.8) (14.1) 200 195 (13.8) (13.4) 185 182 (12.8) (12.6) 122 A106B 316SS 350 350 (24.1) (24.1) 350 350 (24.1) (24.1) 350 350 (24.1) (24.1) 340 340 (23.4) (23.4) 331 331 (22.8) (22.8) 322 322 (22.2) (22.2) 123 A106B 316SS 740 720 (51.0) (49.7) 675 620 (46.6) (42.8) 655 560 (45.2) (38.6) 645 537 (44.5) (37.0) 635 515 (43.8) (35.5) 622 497 (42.9) (34.3) 124 A106B 316SS 1250 1250 (86.2) (86.2) 1250 1250 (86.2) (86.2) 1250 1120 (86.2) (77.2) 1216 1075 (83.9) (74.1) 1182 1030 (81.5) (71.0) 1150 992 (79.3) (68.2) *Consult the factory for pressure ratings of units with Monel trim. Minimum Specific Gravity For Monel Trim please consult factory. Model Series Minimum Specific Gravity (Dual Switch, anti-vibration, pneumatic or extra-high temperature) Standard 316SS / 400SS “B” Trim w/ ET or FE Option All 316SS “C” Trim 316SS / 400SS “B” Trim All 316SS “C” Trim 101 102 103 0.52 0.62 0.51 (0.64) (0.73) (0.57) 0.56 0.66 0.53 (0.67) (0.77) (0.59) 0.56 0.65 0.53 (0.67) (0.76) (0.59) 0.60 0.69 0.55 (0.71) (0.80) (0.61) 104 109 121 0.62 0.38 0.66 (0.68) (0.41) (0.87) 0.64 0.39 0.73 (0.70) (0.42) (0.94) 0.64 0.39 0.72 (0.70) (0.42) (0.93) 0.66 0.40 0.79 (0.72) (0.43) (1.01) 122 123 124 0.66 0.93 0.94 (0.87) - 0.73 0.98 0.99 (0.94) - 0.72 0.99 1.00 (0.94) - 0.79 1.04 1.05 (1.01) - Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 9/60 100 Series Step 2: Chamber Material 101 A-A1C-B-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart on page 9 is based on the material selected here. Consult the factory for alternative materials. Designator Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Step 3: Process Connection 101 A-A1C-B-A1-N4-CRTT Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size 1” 1-1/2” 2” Flange Style NPT Thread Socket Weld 150# 300# 600# VH A1A A1B A1C A1D A1E VV - - B1C B1D B1E VVD C1A C1B C1C C1D C1E VVT - - D1C D1D D1E VH A5A A5B A5C A5D A5E VV - - B5C B5D B5E VVD C5A C5B C5C C5D C5E VVT - - D5C D5D D5E VH A2A* A2B* A2C A2D A2E VV - - B2C B2D B2E VVD C2A* C2B* C2C C2D C2E VVT - - D2C D2D D2E VH (Vertical/Horizontal) VV (Vertical/Vertical) VVD (Vertical/Vertical/ Drain) VVT (Vertical/Vertical/ Tee Drain) *Not available on Models 121 and 122. Step 4: Trim Material Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. 10/60 101 A-A1C-B-A1-N4-CRTT Designator Float Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 100 Series Calibration Dimensions The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog. Model 101 Model 102 Specific Gravity “B” “C” Specific Gravity “B” “C” .52 3-1/4” 4-7/16” .62 2-3/4” 3-13/16” 1.0 5-1/4” 5-15/16” 1.0 4-7/16” 5-1/8” Model 104 Model 103 Specific Gravity “B” “C” Specific Gravity “B” “C” .51 3-1/4” 3-7/8” .62 3-3/8” 3-15/16” 1.0 4-13/16” 5-3/16” 1.0 4-5/8” 5” Model 109 Model 121 Specific Gravity “B” “C” Specific Gravity “B” “C” .38 4-3/4” 5-15/16” .66 2-11/16” 4-1/8” 1.0 7-1/4” 7-9/16” 1.0 3-13/16” 4-13/16” Model 122 Model 123 Specific Gravity “B” “C” Specific Gravity .66 2-1/2” 3-15/16” 1.0 3-5/8” 4-5/8” “B” “C” .93 2-7/8” 3-13/16” 1.0 3-3/16” 4-1/16” Model 124 Specific Gravity “B” “C” .94 2-7/8” 3-13/16” 1.0 3-1/8” 4” Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 11/60 100 Series Chamber Dimensions DRAWING NU Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) MODEL # 0390019 They are subject to change without notice. Contact SOR for PURCHASE ORDER # certified drawings of particular models or if MODEL # SALES ORDER # special dimensions are required. PURCHASE ORDER # LINE ITEM # SALES ORDER DRAWING NUMBER 146.1 OVERHEAD CLEARANCE 5.75 REQUIRED TO REMOVE HOUSING COVER. 101.6 4.00 180.9 7.12 101.6 4.00 * MINIMUM *228.6 9.00 W *228.6 9.00 W L L W 180.9 7.12 14 5.7 REQUIRED TO * MINIMUM THIS DRAWING WAS CREATED USIN THE VERTICAL_MOUNT_ASSY AND FILE 0390019.txt LOCATED ON THE K:\$Engineering Services\Concept tex THEN THE DRAWING WAS CHANGE DRAFT ENTITIES. W 14 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 ISO-9001 CHECKED BY PRODUCT CER ALL DIMEN UNLESS OT J REHM LIN DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN D H M SMITH G ENGINEER APPROVAL J FIFE DATE THIS DRAW NO USE WHA HEREON, NOR MADE WITHOU 3/14/11 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. E 1" SW DIMONLY) DWG 100 SERIES SERVICEABLE (VVT EXTERNAL CHAMBER VH STYLE F DRAWING NUMBER TITLE DIM DWG 100 S EXTERNAL CHAM TITLE F EO NUMBER: 5090 SCALE: DRAWING SCALE 0390019 SHEET Drawing 0390021 Drawing 0390019 Model Name: MODEL NAME.DRAFT/3/0+ DO NOT SCALE PRINT MODEL # Model Name: MODEL NAME.DRAFT/3/1+ EO NUMBER: 5 REV SCALE: DRAWIN 3 1 OF 1 DRAWING DO NOT NUMBE SCALE DWG SIZE A SALES ORDER # Reset Form PURCHASE ORDER # 180.9 7.12 Housing** 101.6 4.00 W General Purpose Explosion Proof Explosion Proof Explosion Proof N4 N7 B1 B2 1” NPT Pneumatic P1 (3) 1/4” NPT ATEX Flame Proof/IS T6 S3 w/CL IECEx Flame Proof S3 S8 W 146.1 5.75 REQUIRED TO RE * MINIMUM *228.6 9.00 L W 14685 M20 x 1.5*** ISO-9001 355.6 14.00 PRODUCT CERTIF ALL DIMENSIO UNLESS OTHE LINEA *Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. **See Housing section (page 48). ***M20 adapters are brass. Contact the factory for alternate materials. THIS DRAWIN NO USE WHATSO HEREON, NOR RE MADE WITHOUT T I TITLE DRAIN CONN 1"NPT OR SW DIM DWG 100 SER EXTERNAL CHAMB E EO NUMBER: 5090 F SCALE: DRAWING DO NOT SCALE PRINT Note: All process flange nipples are 1” standard. 12/60 Registered Quality System to ISO 9001 Model Name: MODEL NAME.DRAFT/3/0+ Drawing 0390010 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 100 Series Chamber Dimensions 1” Connection Model 101 102 103 104 109 121 122 123 124 D1, 2 E1, 2 F4 H4 G inch mm inch mm inch mm inch mm 10-1/2 267 3-3/4 95 6-1/2 165 356 122 14 I2 inch mm 14 356 L2 inch mm 3-3/4 95 10-1/4 260 4-13/16 7-7/16 189 14 356 14 356 4-9/16 116 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95 10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95 inch mm 16-5/8 422 17-5/16 440 18 457 19-3/4 502 17-13/16 452 16-3/8 416 16-15/16 430 17-5/16 440 18-3/4 476 1-1/2” Connection Model 101 102 103 104 109 121 122 123 124 D1, 2 E1, 2 F4 H4 G inch mm inch mm inch mm 10-1/2 267 4 102 6-1/2 165 I2 inch mm inch mm 14 356 14 356 L2 inch mm 3-3/4 95 116 inch mm 16-5/8 422 17-5/16 440 18 457 19-3/4 502 10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191 17-13/16 452 9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95 10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95 16-3/8 416 16-15/16 430 17-5/16 440 18-3/4 476 2” Connection Model 101 102 103 104 109 121 122 123 124 D1, 2 E1, 2 F4 H4 G inch mm inch mm inch mm 10-1/2 267 4-5/16 110 6-1/2 165 I2, 3 inch mm inch mm 14 356 14 356 L2, 3 inch mm 4-3/4 121 inch mm 17-5/8 448 18-5/16 467 19 483 20-3/4 527 10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 4-9/16 116 13-3/8 340 6-3/8 162 8-7/16 214 16 406 16 406 8-1/2 216 18-13/16 478 - - - - 6 152 14 356 14 356 3-3/45 955 10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121 16-3/85 4165 16-15/165 4305 18-5/16 465 19-3/4 502 Notes 1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions. 2. Consult factory for dimensions for materials other than carbon steel. 3. Applies to socket weld or NPT process connections only. 4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above. 5. Applies to flanged process connections only. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 13/60 200 Series Step 1: Model Series 201 A-A1C-B-A1-N4-CRTT The 200 Series mechanical level switch is float operated with a sealed, tamper-proof external chamber. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Model Pressure at Listed Temperature in psig (bar)* Chamber Series Material Working Maximum 100°F (38°C) Pressure 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) See pageA106B 53 for pressure ratings at higher temperatures. 201 316SS 225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.7) 207 (14.3) 202 A106B 316SS 300 (20.7) 300 (20.7) 300 (20.7) 292 (20.1) 284 (19.5) 276 (19.0) 203 A106B 316SS 500 (34.5) 500 (34.5) 500 (34.5) 486 (33.5) 473 (32.6) 460 (31.7) 204 A106B 316SS 1250 (86.2) 1250 (86.2) 1250 1187 (86.2) (81.9) 1216 1139 (83.9) (78.6) 1182 1091 (81.5) (75.2) 1150 1052 (79.3) (72.6) 205 A106B 316SS 750 (51.7) 750 (51.7) 750 (51.7) 729 (50.3) 709 (48.9) 690 (47.6) 206 A106B 316SS 1000 (68.9) 1000 (68.9) 1000 945 (68.9) (65.2) 973 907 (67.1) (62.6) 946 869 (65.2) (59.9) 920 838 (63.4) (57.8 207 A106B 316SS 1000 (68.9) 1000 (68.9) 1000 945 (68.9) (65.2) 973 907 (67.1) (62.6) 946 869 (65.2) (59.9) 920 838 (63.4) (57.8 209 A106B 316SS 450 (31.0) 450 (31.0) 450 (31.0) 438 (30.2) 426 (29.4) 414 (28.6) 221 A106B 316SS 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2) *Consult the factory for pressure ratings of units with Monel trim. Minimum Specific Gravity For Monel Trim please consult factory. Minimum Specific Gravity (Dual Switch, anti-vibration, pneumatic or extra-high temperature) Model Series Standard 316SS / 400SS “B” Trim 14/60 w/ ET or FE Option All 316SS “C” Trim 316SS / 400SS “B” Trim All 316SS “C” Trim 201 202 203 0.38 0.52 0.61 (0.44) (0.63) (0.72) 0.40 0.55 0.65 (0.46) (0.67) (0.76) 0.40 0.55 0.64 (0.44) (0.66) (0.75) 0.42 0.59 0.68 (0.48) (0.70) (0.79) 204 205 206 0.91 0.50 0.65 (0.56) (0.75) 0.96 0.52 0.68 (0.58) (0.79) 0.98 0.52 0.68 (0.58) (0.79) 1.03 0.54 0.71 (0.60) (0.82) 207 209 221 0.61 0.38 0.64 (0.67) (0.41) (0.86) 0.63 0.39 0.72 (0.69) (0.42) (0.93) 0.63 0.39 0.71 (0.69) (0.42) (0.92) 0.65 0.40 0.78 (0.71) (0.43) (0.99) Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 200 Series Step 2: Chamber Material 201 A-A1C-B-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart on this page is based on the material selected here. Consult the factory for alternative materials. Designator Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Step 3: Process Connection 201 A-A1C-B-A1-N4-CRTT Select a process connection, size, style and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size 1” 1-1/2” 2” Flange Style NPT Thread Socket Weld 150# 300# 600# VH A1A A1B A1C A1D A1E VV - - B1C B1D B1E VVD C1A C1B C1C C1D C1E VVT - - D1C D1D D1E VH A5A A5B A5C A5D A5E VV - - B5C B5D B5E VVD C5A C5B C5C C5D C5E VVT - - D5C D5D D5E VH A2A* A2B* A2C A2D A2E VV - - B2C B2D B2E VVD C2A* C2B* C2C C2D C2E VVT - - D2C D2D D2E VH (Vertical/Horizontal) VV (Vertical/Vertical) VVD (Vertical/Vertical/ Drain) VVT (Vertical/Vertical/ Tee Drain) *Not available on Model 221. Step 4: Trim Material 201 A-A1C-B-A1-N4-CRTT Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. Designator Float Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 15/60 200 Series Calibration Dimensions The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog. Model 201 Model 202 Model 203 “B” “C” Specific Gravity “B” “C” Specific Gravity “B” “C” .38 3-3/16” 4” .52 3-1/4” 4-7/16” .61 3” 4-1/16” 1.0 5-3/16” 5-9/16” 1.0 5-1/4” 5-16/16” 1.0 4-3/4” 5-7/16” Specific Gravity Model 206 Model 205 “B” “C” Specific Gravity “B” “C” Specific Gravity “B” .91 3” 3-15/16” .50 3” 3-11/16” .65 3-1/2” 4-1/4” 1.0 3-3/8” 4-1/4” 5” 1.0 4-5/8” 5-1/16” 1.0 4-11/16” Model 207 Model 209 Model 221 “B” “C” Specific Gravity “B” “C” Specific Gravity “B” “C” .61 3” 3-9/16” .38 4-3/4” 5-1/4” .64 2-9/16” 4-1/16” 1.0 4-5/16” 4-5/8” 1.0 7-1/4” 7-1/2” 1.0 3-13/16” 4-13/16” DRAWING NUMBER 0390660 SALES ORDER # Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject LINE ITEM # 0390661 MODEL # SALES ORDER #dimensions are required. to change without notice. Contact SOR for certified drawings of particular models or if special 146.1 * MINIMUM OVERHEAD CLEARANCE DRAWING NUMBER PURCHASE ORDER # 180.9 7.12 MODEL # 101.6 4.00 *228.6 9.00 W L *228.6 9.00 W SALES ORDER # 146.1 180.9 PURCHASE ORDER * MINIMUM OVERHEAD CLEARANCE 7.12DRAWING WAS CREATED 5.75 THIS USING REQUIRED TO REMOVE HOUSING COVER. THE VERTICAL_MOUNT_ASSY AND TEXT FILE 0390660.txt LOCATED ON THE K:\$Engineering Services\Concept text files THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES. 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 W H *228.6 9.00 ISO-9001 J REHM DRAWN BY ENGINEER APPROVAL J FIFE (VVTSCALE: ONLY) DRAWING SCALE DO NOT SCALE PRINT Model Name: MODEL NAME.DRAFT/2/0+ 0390660 F SHEET 1 OF Drawing 1 A 0390661 2 DRAWING NUMBER EO NUMBER: 5090 SCALE: DRAWING SCALE DRAIN CONN 1"NPT OR SW W 1” NPT Pneumatic P1 (3) 1/4” NPT ATEX Flame Proof/IS T6 S3 w/CL IECEx Flame Proof S3 S8 J FIFE DATE PRODUCT CE ALL DIMEN UNLESS O L DIM DWG 200 SERIES SEALED CHAMBER VV, VVT DWG SIZE Model Name: MODEL NAME.DRAFT/1/4+ N4 N7 B1 B2 I SHEET 1 OF 1 E F Registered Quality System to ISO 9001 2 DWG SIZE A Reset Form Drawing 0390662 Note: All process flange nipples are 1” standard. * Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. (Linear = mm/in.) **See Housing section (page 48). ***M20 adapters are brass. Contact the factory for alternate materials. | 913-888-2630 | SORInc.com THIS DRA NO USE WH HEREON, NO MADE WITHO REV 0390661 Model Name: MODEL NAME.DRAFT/1/3+ M20 x 1.5*** ISO-900 ENGINEER APPROVAL TITLE DO NOT SCALE PRINT General Purpose Explosion Proof Explosion Proof Explosion Proof J REHM NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. REV Reset Form Housing** 1 CHECKED BY 355.6 3/15/11 14.00 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. DIM DWG 200 SERIES SEALED CHAMBER VH DRAWING NUMBER M SMITH PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN DATE TITLE EO1" NUMBER: SW 5090 THIS DRAWING WAS CREATED U THE VERTICAL_MOUNT_ASSY AN FILE 0390661.txt LOCATED ON K:\$Engineering Services\Concept THEN THE DRAWING WAS CHAN DRAFT ENTITIES. 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 W SORINC.COM CHECKED BY THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. Drawing 0390660 1 5 REQUIRED TO * MINIMUM L M SMITH G 3/15/11 F 101.6 4.00 W DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN D E 180.9 7.12 L W DRAWING N LINE ITEM # 5.75 REQUIRED TO REMOVE HOUSING COVER. 101.6 4.00 16/60 “C” Specific Gravity Chamber Dimensions PURCHASE ORDER # Low Level Specific Gravity Model 204 MODEL # High Level Form 912 (01.15) ©SOR Inc. TITLE DIM DWG 200 VVD EO NUMBER: SCALE: DRAW DO NOT SCALE 200 Series Chamber Dimensions 1” Connections Model D1, 2 E1, 2 F4 H4 G I1, 2 inch mm inch mm inch mm inch mm inch mm inch mm 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386 10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386 209 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 18-1/16 459 221 9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95 14-3/8 365 201 inch mm L2 202 203 204 205 206 207 1-1/2” Connections Model D2 E2 F4 H4 G I2 L2 inch mm inch mm inch mm inch mm inch mm inch 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386 10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365 10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386 209 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191 18-1/16 459 221 9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95 365 201 mm inch mm 202 203 204 205 206 207 14-3/8 2” Connections Model 201 D2 E2 F4 H4 G I2, 3 inch mm inch L2, 3 inch mm inch mm inch mm inch mm mm inch mm 10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 5-9/16 141 16-3/16 411 10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121 15-3/8 391 10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 5-9/16 141 16-3/16 411 13-3/8 340 6-3/16 162 8-7/16 214 16 406 16 406 191 19-1/16 484 14-3/8 365 202 203 204 205 206 207 209 221 - - - - 6 152 14 356 14 356 7-1/2 5 3-3/4 5 95 Notes 1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions. 2. Consult factory for dimensions for materials other than carbon steel. 3. Applies to socket weld or NPT process connections only. 4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above. 5. Applies to flanged process connections only. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 17/60 108/208 Series Step 1: Model Series 108 A-E1A-F-A1-N4-CRTT The 108/208 Series mechanical level switches are float operated, horizontal mounted with sealed, tamper-proof or flanged, serviceable chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. See page 53 for pressure ratings at higher temperatures. Pressure at Listed Temperature in psid (bar) Model Series Chamber Material 100°F (38 C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) 108 A106B 316SS 740 720 (51.0) (49.6) 675 620 (46.5) (42.7) 655 560 (45.1) (38.6) 645 537 (44.4) (37.0) 635 515 (43.7) (35.5) 622 497 (42.8) (34.2) 208 A106B 316SS 1794 2248 (123.6) (155.0) 1794 1937 (123.6) (133.5) 1794 1746 (123.6) (120.3) 1794 1644 (123.6) (133.4) 1794 1602 (128.0) (110.4) 1794 1548 (128.0) (106.7) Minimum Specific Gravity For all model series on this page, single switch only is equal to .65. Consult the factory for units used with specific gravity lower than .65. Step 2: Chamber Material 108 A-E1A-F-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. Designator Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Step 3: Process Connection Select a process connection style and size from the chart below. Consult the factory for variations. NPT connections not recommended above 900°F. Size E1A E1B E5A E5B E2A E2B Style 108 A-E1A-F-A1-N4-CRTT NPT Thread 1” 1-1/2” 2” NPT SW NPT SW NPT SW Step 4: Trim Material Select the internal trim material from the chart below. 18/60 108 A-E1A-F-A1-N4-CRTT Designator Float Material Attraction Sleeve Available with Chamber Material: F 321 Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only G 321 Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 108/208 Series Chamber Dimensions DRAWIN MODEL # Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) PURCHASE ORDER #0390667 MODEL SALES ORDERdrawings # They# are subject to change without notice. Contact SOR for certified of particular models or if PURCHASE ORDER # LINE ITEM # special dimensions are required. 180.9 SALES ORD DRAWING NUMBER MODEL 180.9 7.12 101.6 4.00 Model 108 CONNECTION SIZE C 7.12 B 125.4 250.8 1" 4.94 9.88 128.5 257.0 1-1/2" 5.06 10.12 138.2 276.4 2" 5.44 10.88 120.7 241.3 1" 4.75 Model 208 9.50 130.3 260.6 1-1/2" 5.13 10.26 A 143.0 186.0 2" B 5.63 11.25 108A (CS) *228.6 9.00 108C (316SST) W 317.5 B 12.50 *228.6 9.00 1 208C (316SST) 1 THIS DRAWING WAS CREATED W THE HORIZ_MOUNT_ASSY AN FILE 0390667.txt LOCATED ON ISO-9 K:\$Engineering Services\Conce C THEN THE DRAWING WAS CH PRODUCT DRAFT ENTITIES. ALL DIM UNLESS DRAWN BY 164.3 187.3 Drawing 0390667 200.8 7.91 THIS D NO USE W HEREON, MADE WIT THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE Model WITHOUT Name: MODEL NAME.DRAFT/2/0+ MADE THE EXPRESS WRITTEN PERMISSION OF SOR. General Purpose Explosion Proof DIM DWG 108 SERIES HORIZONITAL Explosion Proof MOUNT FLOAT OPERATED Explosion Proof EO NUMBER: 5090 TITLE 146.1 DRAWING NUMBER DRAWING SCALE Pneumatic DO NOT SCALE PRINT 1” Connections A inch N4 N7 B1 B2 0390667 P1 SHEET 1 OF 1 mm inch 108 4-13/16 1 122 208 4-15/16 125 DIM DWG 20 MOUNT FLO SCALE: DRA REV 2 DWG SIZE (3) 1/4” NPT A T6 Reset Form S3 w/CL IECEx Flame Proof S3 S8 M20 x 1.5*** C mm inch mm 9-5/8 2 244 15-1/2 394 9-7/8 250 15-5/8 396 2 EO NUMBER 1” NPT ATEX Flame Proof/IS B 1 TITLE 146.1 * OVERHEAD CLEARANCE W 5.75 REQUIRED TO REMOVE COVER. 3/16/11 Housing** 187.3 7.38 573.1 22.56 * OVERHEAD CLEARANCE * Minimum 5-3/4” 5.75(146 mm) overhead clearance REQUIRED TO REMOVE required to remove housing cover. COVER. SCALE: **See Housing section (page 48). ***M20 adapters are brass. Contact the factory for alternate materials. Model DATE 1-1/2” Connections Model A1 B1 C1 inch mm inch mm inch mm 108 5-1/16 129 10-1/8 258 15-3/4 401 208 5-1/16 129 10-1/8 258 15-3/4 401 2” Connections Model A1 B1 C1 inch mm inch mm inch mm 108 5-3/8 137 10-3/4 274 16-1/8 409 208 5-3/8 137 10-3/4 274 16-1/8 409 Notes 1. Dimensions valid for socket weld process connections. Consult factory for threaded connection dimensions. Form 912 (01.15) ©SOR Inc. SORInc.com CONN S 208A (CS) 101.6 4.00 M SMITH 6.47 DRAWING 7.38 PRODUCT CERTIFICATION CHECKED BY ALL DIMENSIONS ARE ±1/16 IN 500.0 J REHM UNLESS OTHERWISE SPECIFIED 19.69 ENGINEER APPROVAL MM LINEAR = J FIFE IN Drawing 0390666 Model Name: MODEL NAME.DRAFT/2/0+ 399.0 15.71 402.1 15.83 411.7 16.21 394.2 15.52 403.9 15.90 416.6 16.40 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 C A A MODEL | 913-888-2630 | Registered Quality System to ISO 9001 19/60 DO NOT SC 300 Series Step 1: Model Series 301 A-F1A-B-A1-N4-CRTT The 300 series mechanical level switches are float-operated switches suitable for top-insertion mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Pressure at Listed Temperature in psid (bar)* Model Series 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) 301 225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.6) 207 (14.2) 303 500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7) 304 750 (51.7) 750 (51.7) 750 (51.7) 729 (50.2) 709 (48.8) 690 (47.5) *Consult the factory for pressure ratings of units with Monel trim. Minimum Specific Gravity Minimum specific gravity will be lower for shorter insertion depths. Consult the factory. Model Series Insertion Depth* Minimum Specific Gravity Single Switch (Dual Switch, anti-vibration, pneumatic or extra-high temperature) 316SS / 400SS Trim (B) All 316SS Trim (C) All Monel Trim (M) 301 24” 48” .40 .44 (.45) (.49) .42 .46 (.48) (.52) .48 .53 (.54) (.59) 303 24” 48” .68 .75 (.79) (.87) .72 .80 (.84) (.91) .82 .91 (.93) (1.02) 304 24” 48” .52 .56 (.58) (.62) .55 .59 (.61) (.65) .62 .67 (.68) (.73) *Insertion depth is defined as the approximate value of a rising level setpoint at a Specific Gravity of 1.0. If more precise setpoint action is required, please select the SC option from the accessories section of the catalog. Please note: An insertion depth or SC information must be supplied at the time of order on all 300 series switches. Step 2: Process Connection Material 301 A-F1A-B-A1-N4-CRTT Select process connection material from the following chart. Designator 20/60 Material A A106 Carbon Steel C A182-TP316/316L Stainless Steel Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 300 Series Step 3: Process Connection 301 A-F1A-B-A1-N4-CRTT Select a process connection, size and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Select Designator Flange Size NPT Thread 150# 300# 600# 1” F1A - - - 2” F2A - - - 3” F3A F3C F3D F3E 4” - F4C F4D F4E 6” - F6C F6D F6E NPT Mounting Flange Mounting Note: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection, or that the vessel has access to attach the float from inside the vessel after instrument installation. See page 22 for float dimensions. Step 4: Trim Material 301 A-F1A-B-A1-N4-CRTT Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. Designator Float Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 21/60 300 Series Unit Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.) MODEL # Standard Units SALES ORDER # LINE ITEM # 180.9 7.12 FLOAT SIZ 139.7 5.50 88.9 15 X 3.5 6.0 13.7 5.50 301 180.9 7.12 101.6 4.00 101.6 4.00 MODEL 303 180.9 7.12 180.9 7.12 101.6 4.00 PURCHASE ORDER # Tandem Float Units MODEL MODEL 301/304 303 101.6 4.00 304 146.1 OVERHEAD CLEARAN 5.75 REQUIRED TO REMOVE C * 227.0 8.94 227.0 8.94 227.0 8.94 W W 62.7 2.47 W 99.2 3.91 227.0 8.94 W PROCESS CONNECTION FLANGE D PROCESS CONNECTION FLANGE B C PROCESS CONNECTION 1 NPT(M) DIFFERENTIAL "C" : __________ A PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 B CHECKED BY ENGINEER APPROVAL J FIFE DATE 3/6/12 Drawing 0390053 E IS BASED ON MINIMUM DIFFERENTIAL SETTING, LIQUID SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION. MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE TO PROVIDE FLOAT INSERTION CLEARANCE. Drawing 0390007 PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN FLOAT M SMITH C DIM DWG 300 SERIES 1" NPT 1. FLOAT SIZE IS BASED ON MINIMUM DIFFERENTIAL SETTING, (FLOAT OPERATED) MINIMUM LIQUID SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION. EO NUMBER: 5154 2. CAUTION MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE. M SMITH ISO-9001 ENGINEER APPROVAL DATE 3/6/12 C LOWER FLOAT DRAWING NUMBER EO NUMBER: 5154 0390007 SCALE: 0.33 B SHEET 1 OF 1 DO NOT SCALE PRINT REV Drawing 0390665 4 DWG SIZE B NOTE: 1. FLOAT SIZE IS BASED ON MINIMUM DIFFERENTIAL SETTING, MINIMUM SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION. Minimum 5-3/4’’ (146 mm) overhead clearance required toLIQUID remove housing cover. 2. CAUTION MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE 2 Housing** ***M20 adapters are brass. Contact the factory for alternate materials. 1” NPT Pneumatic P1 (3) 1/4” NPT ATEX Flame Proof/IS T6 S3 w/CL IECEx Flame Proof S3 S8 Series 303 Minimum Insertion Float Size mm inch 3-1/2 x 6” 114 4-1/2 5-1/2” 108 4-1/4 301 304 Maximum Insertion mm inch 1219 48 M20 x 1.5*** Tandem Float Units High Insertion Series 303 301 304 Float Size Minimum Low Insertion Differential Maximum Minimum Maximum Minimum Maximum mm inch mm inch mm inch mm inch mm inch mm inch 3-1/2 x 6” 114 4-1/2 1016 40 305 12 1219 48 203 8 1105 43-1/2 5-1/2” 108 4-1/4 1041 41 279 11 1219 48 178 7 1111 43-3/4 Notes 1. Standard Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection, or that the vessel has access to attach the float from inside the vessel after instrument installation. 2. Tandem Float Units: It is important to consider the installation configuration when selecting the process connection. Be sure that the float will fit through the process connection. Tandem floats are not removable and must be installed through the nozzle opening. Operating specific gravity and insertion depths must be specified. 22/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com DIM DWG 300 SERIES FLANGED (FLOAT OPERATED) DO NOT SCALE PRINT Standard Units W N4 N7 B1 B2 TITLE SCALE: 0.20 Model Name: 0390665_OPT.ASSEM//0 General Purpose Explosion Proof Explosion Proof Explosion Proof THIS DRAWING IS THE EXCLUSI NO USE WHATSOEVER OF THE INF HEREON, NOR REPRODUCTION IN MADE WITHOUT THE EXPRESS WRIT EO NUMBER: 5195 SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE. ** See Housing section (page 48). PRODUCT CERTIFICATION DRA ALL DIMENSIONS ARE ±1/1 UNLESS OTHERWISE SPECIF MM LINEAR = IN DIM DWG 300 SERIES FLANGED FLOAT OPERATED 4 DWG SIZE M/3/3+ Model Name: 0390007.ASSEM/3/0+ 14685 W 105TH S 91 SO J FIFE LOWER FLOAT REV 0390053 SHEET 1 OF 1 DO NOT SCALE PRINT CHECKED BY TITLE DRAWING NUMBER SCALE: 0.33 ELECTRICAL CONN. "W" : _____ J REHM THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE FLANGE "D" : ______________ B DRAWN BY J REHM THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. NOTES: UPPER FLOAT UPPER FLOAT 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 DRAWN BY HIGH INSERTION DEPTH "A" : _ LOW INSERTION DEPTH "B" : _ A FLOAT PROCESS CONNECTION FLANGE D 62.7 2.47 Form 912 (01.15) ©SOR Inc. DRAWING SH 400 Series Step 1: Model Series 401 A-G3A-B-A1-N4-CRTT The 400 Series mechanical level switch is float operated suitable for horizontal-insertion mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Maximum Working Pressure Pressure at Listed Temperature in psig (bar)* Model Series Chamber Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) 401 A106B 316SS 230 (15.8) 230 (15.8) 230 (15.8) 224 (15.4) 218 (15.0) 212 (14.6) 402 A106B 316SS 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2) 403 A106B 316SS 230 (15.8) 230 (15.8) 230 215 (15.8) (14.8) 215 205 (14.8) (14.1) 200 195 (13.7) (13.4) 185 182 (12.7) (12.5) 404 A106B 316SS 500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7) 405 A106B 316SS 740 720 (51.0) (49.6) 675 620 (46.5) (42.7) 655 560 (46.1) (38.6) 645 537 (44.4) (37.0) 635 515 (43.7) (35.5) 618 497 (42.6) (34.2) 406 A106B 316SS 1250 (86.2) 1250 1240 (86.2) (85.5) 1250 1120 (86.2) (77.2) 1216 1075 (83.8) (74.1) 1182 1030 (81.5) (71.0) 1150 992 (79.3) (68.4) *Consult the factory for pressure ratings of units with Monel trim Minimum Specific Gravity Model Single Switch 401 .50 402 .90 403 .50 404 .60 405 .60 406 .60 Note: Insertion depth may affect minimum specific gravity. Step 2: Chamber Material 401 A-G3A-B-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. Designator Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 23/60 400 Series Step 3: Process Connection 401 A-G3A-B-A1-N4-CRTT Select a process connection designator from the chart below based on style and size. Consult the factory for variations. 3” flanged process connections may require the float to be installed from inside the process connection. Connection Model Float Size Designator Size 401 3” G3A 3” NPT(M) Thread 402 2-1/2” G7A 2-1/2” NPT(M) Thread 403 3” 403 3” 404 3 x 6” G3F G4F G3A 3” 4” 3” Style 150# RF Weld Neck Flange 150# RF Weld Neck Flange NPT(M) Thread Connection Model Float Size Designator Size Style 405 3 x 6” G3G 3” 300# RF Weld Neck Flange 405 3 x 6” G4G 4” 300# RF Weld Neck Flange 406 3 x 6” G3H 3” 600# RF Weld Neck Flange 406 3 x 6” G4H 4” 600# RF Weld Neck Flange Step 4: Trim Material 401 A-G3A-B-A1-N4-CRTT Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. Designator Float Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Chamber Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.) Housing** General Purpose Explosion Proof Explosion Proof Explosion Proof Models 403, 405, 406 Models 401, 402, 404 Drawing 0390668 Drawing 0390669 MODEL # 217.5 8.56 Pneumatic SALES ORDER # LINE ITEM # N ATEX Flame Proof/IS 101.6 4.00 (3) 1/4” NPT T6 MODEL S3 403 w/CL MAXIMUM DIFFERENTIAL (D) FLANGED UNITS S3 406** S8 Flame Proof W P1 405** IECEx *227.0 8.94 1” NPT PURCHASE ORDER # 1 180.9 7.12 W N4 N7 B1 B2 NOZZLE LENGTH (N) 51 2.0 102 4.0 M20229 x 9.0 1.5*** 152 330 13.0 152 6.0 203 8.0 254 10.0 178 7.0 127 5.0 114 4.5 127 5.0 6.0 **BASED ON 4" FLANGE SIZE CUSTOMER PROCESS CONNECTION STANDARD DIFFERENTIAL (D) MODEL *Minimum 146.1 overhead clearance required to remove 5.75 housing cover. ** See Housing section (page 48). ***M20 adapters are brass. Contact the factory for alternate materials. "D" @ MIN. S.G. 51 2.0 403 118.3 4.66 405 FLOAT 44.5 1.75 406 D 1 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 DRAWN BY PROCESS CONNECTION WELD NECK FLANGE PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN J REHM ENGINEER APPROVAL J FIFE DATE 08 APR 2011 457 18.0 263.5 10.38 K MITCHELL CHECKED BY THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE 146.1 OVERHEAD CLEARANCE 5.75 REQUIRED TO REMOVE HOUSING COVER. DIM DWG 403,405,406 FLOAT OPERATED * MINIMUM 24/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com ELECTRICAL CONN. "W" : __________ Model Name: 0390669.ASSEM/1/5+ NOTES: 1 EO NUMBER: 5090 Form 912 (01.15) ©SOR Inc. 1. STANDARD DIFFERENTIAL. FOR MAXIMUM DIFFERENTIAL, SEE TABLE. SCALE: 0.33 DO NOT SCALE PRINT DRAWING NUMBER REV 0390669 2 SHEET 1 OF 1 DWG SIZE B Reset Form 400 Series Calibration Dimensions Standard Differential (D) Model “D” @ Minimum Specific Gravity 401 402 Note: With anti-vibration, extra-high temperature and pneumatic switch, minimum differential will increase. 3” (76 mm) 403 404 405 2-3/4” (70 mm) 406 Maximum Differential (D) Differential Dimension “D” is calibrated to the minimum shown above as standard. Wider differentials are available by placing an SC in the accessory section of the model number. The charts below give the maximum differentials available. NPT Units Customer Mounting Model 1/2 Coupling Full Coupling 401 12-3/8” (356 mm) 10-1/4” (292 mm) 402 8-7/8” (292 mm) 8-7/8” (292 mm) 404 12-3/8” (356 mm) 10-1/4” (292 mm) Flanged Units Model 403 Customer Nozzle Length (N) 2” (51 mm) 4” (102 mm) 6” (152 mm) 8” (203 mm) 10” (254 mm) 13” (330 mm) 9” (229 mm) 7” (178 mm) 5” (127 mm) 4-1/2” (114 mm) 405* 406* 6” (152 mm) 5” (127 mm) *Based on 4-inch flange size. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 25/60 741-743 and 802 Series Step 1: Model Series 741 A-A1C -B-A1-N4-CRTT The 741-743 and 802 Series mechanical level switches are displacer-operated with flanged, serviceable external chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Maximum Working Pressure Pressure at Listed Temperature in psig (bar)* Model Series Chamber Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) 741 A106B 316SS 285 275 (19.7) (18.9) 260 240 (17.4) (16.5) 230 215 (15.8) (14.8) 215 205 (14.8) (14.1) 200 195 (13.7) (13.4) 185 182 (12.7) (12.5) 742 A106B 316SS 740 720 (51.0) (49.6) 680 620 (46.9) (42.7) 655 560 (45.1) (38.6) 645 537 (44.4) (37.0) 635 515 (43.7) (35.5) 618 497 (42.6) (34.2) 743 A106B 316SS 1480 1440 (102.0) (99.3) 1294 1240 (89.2) (85.5) 1166 1120 (80.4) (77.2) 1118 1075 (77.1) (74.1) 1070 1025 (73.8) (70.7) 1034 990 (71.3) (68.3) 802 A106B 316SS 3376 3600 (232.8) (248.2) 3376 3095 (232.8) (213.4) 3270 2795 (225.5) (192.7) 3220 2683 (222.0) (185.0) 3170 2570 (218.6) (177.2) 3092 2480 (213.2) (171.0) *Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available above 450°F (232°C). Minimum Specific Gravity Model Series Standard Anti-Vibration or Pneumatic 0.43 0.57 0.41 0.5 741 742 743 802 Step 2: Chamber Material 741 A-A1C-B-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternate materials. Designator 26/60 Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 741-743 and 802 Series Step 3: Process Connection 741 A-A1C-B-A1-N4-CRTT Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size 1” 1-1/2” 2” Style NPT Thread Socket Weld VH A1A VV Flange 150# RF 300# 600# 1500# RF RF RTJ A1B A1C A1D A1E A1T - - B1C B1D B1E B1T VVD C1A C1B C1C C1D C1E C1T VVT - - D1C D1D D1E D1T VH A5A A5B A5C A5D A5E A5T VV - - B5C B5D B5E B5T VVD C5A C5B C5C C5D C5E C5T VVT - - D5C D5D D5E D5T VH A2A* A2B* A2C A2D A2E A2T VV - - B2C B2D B2E B2T VVD C2A* C2B* C2C C2D C2E C2T VVT - - D2C D2D D2E D2T VV VH (Vertical/Horizontal) (Vertical/Vertical) VVD (Vertical/Vertical/ Drain) VVT (Vertical/Vertical/ Tee Drain) *Not available on Models 741, 742, and 743. Step 4: Trim Material 741 A-A1C-B-A1-N4-CRTT Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. Designator Displacer Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 27/60 741-743 and 802 Series Calibration Dimensions The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog. Model 802 Model 741, 742, 743 Specific Gravity “B” “C” Specific Gravity “B” “C” .43 1-13/16” 4-5/8” .41 2-3/8” 5-5/16” 1.0 4-9/16” 6-1/16” 1.0 5-1/16” 6-7/16” Chamber Dimensions DRAWING NUMBER MODEL as # Dimensions listed are for reference only and are expressed millimeters over inches. (Linear = mm/in.) 0390019 PURCHASE ORDER # SALES ORDER # They are subject to change without notice. Contact SOR for certified drawings of particular models or if PURCHASE ORDER # LINE ITEM # special dimensions are required. SALES ORDER # DRAWING NUMBER MODEL # 101.6 4.00 * MINIMUM *228.6 9.00 W 180.9 7.12 146.1 OVERHEAD CLEARANCE 5.75 REQUIRED TO REMOVE HOUSING COVER. 180.9 7.12 146.1 5.75 REQUIRED TO REM * MINIMUM 101.6 4.00 THIS DRAWING WAS CREATED USING THE *228.6 VERTICAL_MOUNT_ASSY AND TEXT 9.00 FILE 0390019.txt LOCATED ON THE K:\$Engineering Services\Concept text files L THEN THE DRAWING WAS CHANGED TO DRAFT ENTITIES. W L W W 14685 ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 PRODUCT CERTIF ALL DIMENSIO UNLESS OTHE DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN D H M SMITH CHECKED BY J REHM ENGINEER APPROVAL LINEA G J FIFE THIS DRAWING NO USE WHATSOE HEREON, NOR REP MADE WITHOUT TH DATE 3/14/11 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. 1" SW (VVT ONLY) DIM DWG 100 SERIES SERVICEABLE E Drawing 0390019 F EO NUMBER: 5090 DRAWING NUMBER MODEL # 0390019 Note: All process flange nipples are 1” standard. Model Name: MODEL NAME.DRAFT/3/1+ Housing** General Purpose Explosion Proof Explosion Proof Explosion Proof Pneumatic ATEX Flame Proof/IS P1 (3) 1/4” NPT T6 S3 w/CL S3 S8 M20 x 1.5*** 0390010 SCALE: DRAWING S DO NOT SCALE PRINT LI DWG SIZE A 180.9 7.12 Reset Form 101.6 4.00 W 1” NPT DRAWING NUMBER SALES ORDER # 3 W N4 N7 B1 B2 EO NUMBER: 5090 Drawing 0390021 REV DO NOT SCALE PRINT Flame Proof DIM DWG 100 SERI EXTERNAL CHAMBE F EXTERNAL CHAMBER VH STYLE PURCHASE ORDER # SCALE: DRAWING Model Name: SCALE MODEL NAME.DRAFT/3/0+ SHEET 1 OF 1 IECEx TITLE TITLE 146.1 OVERHEA 5.75 REQUIRED TO REMOVE HOU * MINIMUM *228.6 9.00 L W *Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. **See Housing section. (Page 48.) ***M20 adapters are brass. Contact the factory for alternate materials. DRAIN CONN 1"NPT OR SW 14685 W 105TH ST 913 SOR ISO-9001 PRODUCT CERTIFICATION DRA ALL DIMENSIONS ARE ±1/1 UNLESS OTHERWISE SPECIF MM LINEAR = IN 355.6 14.00 THIS DRAWING IS THE EXCLUSI NO USE WHATSOEVER OF THE IN HEREON, NOR REPRODUCTION IN MADE WITHOUT THE EXPRESS WRI I TITLE E F Drawing 0390010 DIM DWG 100 SERIES SERVICEAB EXTERNAL CHAMBER VVD STYLE EO NUMBER: 5090 SCALE: DRAWING SCALE DO NOT SCALE PRINT Model Name: MODEL NAME.DRAFT/3/0+ 28/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. DRAWING SH 741-743 and 802 Series Chamber Dimensions 1” Connections Model D1, 2 E1, 2 F4 inch mm inch mm 13 330 3-1/4 83 H4 G inch mm inch mm I2 inch mm L2 inch mm 3-3/4 95 741 742 6 152 16 406 16 406 743 802 12-3/4 324 3-7/8 98 8 203 16 406 16 406 6-3/4 171 inch mm 19-5/16 491 19-1/2 495 19-7/8 505 20-3/4 527 1-1/2” Connections Model D2 inch E2 mm inch F4 mm H4 G inch mm inch mm I2 inch mm inch L2 mm 741 742 13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95 743 802 12-7/8 327 4 102 8 203 16 406 16 406 6-3/4 171 inch mm 19-5/16 491 19-1/2 495 19-7/8 505 20-3/4 527 2” Connections Model D2 inch E2 mm inch F4 mm H4 G inch mm inch mm I2, 3 inch mm inch L2, 3 mm 742 - - - - 6 152 16 406 16 406 3-3/45 955 743 802 inch mm 19-5/165 4915 741 13-3/16 335 4-5/16 110 8 203 16 406 16 406 7-3/4 197 19-1/25 4955 19-7/85 5055 21-5/16 541 Notes 1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions. 2. Consult factory for dimensions for materials other than carbon steel. 3. Applies to socket weld or NPT process connections only. 4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above. 5. Applies to flanged process connections only. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 29/60 740 and 804 Series Step 1: Model Series 740 A-A1C-B-A1-N4-CRTT The 740 and 804 Series mechanical level switches are displacer operated with sealed, tamper-proof external chambers. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Maximum Working Pressure Model Series Chamber Material 740 804 Pressure at Listed Temperature in psig (bar)* 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C) A106B 316SS 1480 (102.0) 1465 (101.0) 1450 (100.0) 1436 (99.0) 1420 (97.9) 1380 (95.1) A106B 316SS 3376 3728 (232.8) (257.0) 3376 3647 (232.8) (251.5) 3376 3286 (232.8) (226.6) 3376 3151 (232.8) (217.3) 3376 3016 (232.8) (207.9) 3376 2915 (232.8) (201.0) *Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available over 450oF (232oC). Minimum Specific Gravity Model Series Standard Anti-Vibration or Pneumatic 740 0.43 0.57 804 0.41 0.50 Step 2: Chamber Material 740 A-A1C-B-A1-N4-CRTT Select chamber material from the following chart. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. Designator 30/60 Material A A106 Grade B Carbon Steel with A105 and A234-WPB fittings C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 740 and 804 Series Step 3: Process Connection 740 A-A1C-B-A1-N4-CRTT Select a process connection size, style and designator from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size 1” 1-1/2” 2” Style NPT Thread Socket Weld VH A1A A1B Flange 150# RF 300# RF 600# RF 1500# RTJ A1C A1D A1E A1T VV - - B1C B1D B1E B1T VVD C1A C1B C1C C1D C1E C1T VVT - - D1C D1D D1E D1T VH A5A A5B A5C A5D A5E A5T VV - - B5C B5D B5E B5T VVD C5A C5B C5C C5D C5E C5T VVT - - D5C D5D D5E D5T VH A2A* A2B* A2C A2D A2E A2T VV - - B2C B2D B2E B2T VVD C2A* C2B* C2C C2D C2E C2T VVT - - D2C D2D D2E D2T VH (Vertical/Horizontal) VV (Vertical/Vertical) VVD (Vertical/Vertical/ Drain) VVT (Vertical/Vertical/ Tee Drain) *Not available on Model 740. Step 4: Trim Material 740 A-A1C-B-A1-N4-CRTT Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim. Designator Displacer Material Attraction Sleeve Available with Chamber Material: B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only C 316/316L Stainless Steel 316/316L Stainless Steel A106 Carbon Steel (A) or 316/316L Stainless Steel (C) M Monel 400 Monel 400 A106 Carbon Steel (A) or 316/316L Stainless Steel (C) Calibration Dimensions The charts below provide typical standard Set Points. As the specific gravity used on a level switch changes, the Set Points will also change. These values are based on the specific gravity listed and units with “B” trim and an A1 switch. For other materials or switches, please consult factory. If a specific Set Point is needed, please use the “SC” option found in the accessories section of this catalog. Model 740 Specific Gravity “B” .43 1.0 Model 804 “C” Specific Gravity 1-13/16” 4-5/8” 4-9/16” 6-1/16” Form 912 (01.15) ©SOR Inc. “B” “C” .41 2-3/8” 5-5/16” 1.0 5-1/16” 6-7/16” SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 31/60 DRAWING NUMBER 0390661 740 and 804 Series Chamber Dimensions MODEL # SALES ORDER # PURCHASE ORDER # Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.) They are subject to change without notice. Contact SOR for certified drawings of particular models or if special dimensions are required. 146.1 OVERH 5.75 REQUIRED TO REMOVE H 180.9 7.12 * MINIMUM 101.6 4.00 DRAWING NUMBER 0390660 MODEL # SALES ORDER # PURCHASE ORDER # W *228.6 LINE ITEM # 9.00 L 146.1 OVERHEAD CLEARANCE 5.75 W REQUIRED TO REMOVE HOUSING COVER. * MINIMUM Housing** General Purpose Explosion Proof Explosion Proof Explosion Proof 180.9 7.12 W N4 N7 B1 B2 1” NPT *228.6 9.00 W P1 (3) 1/4” NPT ATEX Flame Proof/IS T6 S3 w/CL IECEx S3 S8 Flame Proof THIS DRAWING WAS CREAT PRODUCT CERTIFICATION ALL DIMENSIONS ARE ± THE VERTICAL_MOUNT_AS UNLESS OTHERWISE SP FILE 0390660.txt LOCATED MM LINEAR = IN K:\$Engineering Services\Co THEN THE DRAWING WAS THIS DRAWING IS THE EXC NO USE WHATSOEVER OF TH DRAFT ENTITIES. HEREON, NOR REPRODUCTIO G L Pneumatic 14685 W 105TH 9 ISO-9001 101.6 4.00 MODEL #(VVT W DRAWING NUMBER MADE WITHOUT THE EXPRESS 1" SW ONLY) F PURCHASE ORDER # 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 Drawing 0390661 SORINC.COM 180.9 7.12 ISO-9001 DRAWN BY Model Name: MODEL NAME.DRAFT/1/4+ PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN D M20 x 1.5*** H W M SMITH 101.6 CHECKED BY 4.00 J REHM VV, VVT LIN EO NUMBER: 5090 DRA SCALE: DRAWING 146.1 SCALE * MINIMUM OVERHEA DO NOT SCALE PRINT 5.75 REQUIRED TO REMOVE HOU ENGINEER APPROVAL J FIFE DATE *228.6 3/15/11 9.00 THIS DRAWING IS THE EXCLUSIVE LPROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION W OF SOR. *Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. **See Housing section (page 48). ***M20 adapters are brass. Contact the factory for alternate materials. E F TITLE Drawing 0390660 DIM DWG 200 SERIES SEALED CHAMBER VH DRAWING NUMBER EO NUMBER: 5090 SCALE: DRAWING SCALE DO NOT SCALE PRINT 14685 W 105TH ST 913SOR ISO-9001 REV 0390660 355.6 SHEET 14.001 OF 1 Model Name: MODEL NAME.DRAFT/2/0+ 2 DWG SIZE A Reset Form PRODUCT CERTIFICATION DRA ALL DIMENSIONS ARE ±1/1 UNLESS OTHERWISE SPECIF MM LINEAR = IN THIS DRAWING IS THE EXCLUSI NO USE WHATSOEVER OF THE INF HEREON, NOR REPRODUCTION IN MADE WITHOUT THE EXPRESS WRIT I TITLE Note: All process flange nipples are 1” standard. DRAIN CONN 1"NPT OR SW 1” Connection Drawing 0390662 E F D1, 2 E1, 2 F4 H4 G inch mm inch mm I2 inch mm L2 inch mm inch mm inch mm inch mm 740 13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95 20-1/4 514 804 12-3/4 324 3-7/8 98 8 203 16 406 16 406 6-3/4 171 21-3/4 552 1-1/2” Connection Model D2 E2 F4 H4 G inch mm inch mm 740 13 330 3-1/2 89 6 152 16 406 16 804 12-7/8 327 4 102 8 203 16 406 16 inch mm inch mm I2 inch mm L2 inch mm inch mm 406 3-3/4 95 20-1/4 514 406 6-3/4 171 21-3/4 552 2” Connection Model D2 inch E2 mm inch F4 mm H4 G inch mm inch mm I2, 3 inch mm inch L2, 3 mm 5 inch mm 5 5 740 - - - - 6 152 16 406 16 406 3-3/4 95 20-1/4 5145 804 13-3/16 335 4-5/16 110 8 203 16 406 16 406 7-3/4 197 21-3/4 552 Notes 1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions. 2. Consult factory for dimensions for materials other than carbon steel. 3. Applies to socket weld or NPT process connections only. 4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above. 5. Applies to flanged process connections only. 32/60 DIM DWG 200 SERIES SEALED CH VVD EO NUMBER: 5090 SCALE: DRAWING SCALE DO NOT SCALE PRINT Model Name: MODEL NAME.DRAFT/1/3+ Model 0390662 TITLE SALES ORDER # SERIES SEALED DIM DWG 200 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. DRAWING SH 700 Series Step 1: Model Series 702 A-F7A-B-A1-N4-CRTT The 700 Series mechanical level switches are single-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Minimum specific gravity is based on single switch. Anti-vibration and pneumatic switches have higher minimum specific gravities. Maximum Working Pressure Model Series Minimum Specific Gravity 701 0.51 702 0.45 703 0.51 704 Function Connection Style NPT Narrow Differential 0.45 Flange 705 NPT 707 0.50 Connection Material 100°F (38°C) 450°F (232°C) Porcelain All 1000 (69) 750 (52) SS All 1000 (69) 750 (52) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) Porcelain All 1000 (69) 750 (52) SS All 1000 (69) 750 (52) A105 285 (20) 185 (13) 316SS 275 (20) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) Porcelain Flange 706 Wide Differential 708 Flange Pressure Rating - psig (bar) Displacer Material SS Porcelain Flange SS Displacer units are not available over 450°F (232°C). *An operating specific gravity is required for models 705 through 708 at time of order. Step 2: Process Connection Material 702 A -F7A-B-A1-N4-CRTT Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. Designator Material A A105 Carbon Steel fittings or flanges C A182-TP316/316L Stainless Steel fittings or flanges Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 33/60 700 Series Step 3: Process Connection 702 A -F7A-B-A1-N4-CRTT Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size Style 2-1/2” 3” 4” 6” Model 701 702 703 704 705 706 707 708 NPT F7A F7A - - F7A F7A - - NPT F3A F3A - - F3A F3A - - 150# RF Flange - - F3C F3C - - F3C F3C 300# RF Flange - - F3D F3D - - F3D F3D 150# RF Flange - - F4C F4C - - F4C F4C 300# RF Flange - - F4D F4D - - F4D F4D 150# RF Flange - - F6C F6C - - F6C F6C 300# RF Flange - - F6D F6D - - F6D F6D Step 4: Trim Material 702 A -F7A-B-A1-N4-CRTT Select the internal trim material from the chart below. Model Displacer Material Attraction Sleeve Construction Material 701 702 703 704 705 706 707 708 316/316L SS 400SS A only - B - B - B - B 316/316L SS 316/316L SS A or C - C - C - C - C Porcelain 400SS A only P - P - P - P - Porcelain 316/316L SS A or C R - R - R - R - Standard displacer spring material is Inconel 600. 34/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 700 Series Unit Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.) Model 701/703 2-1/2” NPT/Flanged Narrow Differential MODEL # MODEL # SALES ORDER # Model 702/704 2-1/2” NPT/Flanged Narrow Differential SALES ORDER # LINE ITEM # LINE ITEM # PURCHASE ORDER # 1 SALES PAGE 146.1 OVERHEAD CLEARANCE REQUIRED 5.75 TO REMOVE HOUSING COVER. * MINIMUM PURCHASE ORDER # NPT A 180.9 7.12 180.9 180.9 7.12 7.12 101.6 4.00 180.9 FLANGE B 7.12 Narrow Differential Models 701-704: 101.6 4.00 Actuation differential is approximately 1-7/16’’ @ Specific Gravity of 1.0 @ 100°F. 101.6 4.00 101.6 4.00 DIMENSION C SEE CHART DIMENSION D SEE CHART ELECTRICAL CONNECTION W *227.0 8.94 DIMENSION C *227.0 *227.0 8.94 8.94 W W PROCESS CONNECTION NPT A D *227.0 SIZE 8.94 W PROCESS CONNECTION PROCESS 2-1/2CONNECTION NPT(M)(STD) 3 NPT(M)(OPT) FLANGE B C 3048 120.0 316 SST CABLE 3048 3048 120.0 316 120.0 SST 316 SST CABLE LOW 3 NPTM 316 SST146.1 OVERHEAD CLEARANCE * MINIMUM CABLE5.75 REQUIRED TO REMOVE HOUSING COVER 14685 W 105TH ST LENEXA, KS 66215 USA HIGH 913-888-2630 SORINC.COM ISO-9001 HIGH SWITCH ACTUATIONSWITCH 195.6 316 SST 7.70 DISPLACER LOW PORCELAIN DISPLACER MODEL 701 Drawing 0390670 SCALE 0.25 84.9 3.34 87.9 3.46 2-1/2 NPTM MINIMUM 229 9.0 PORCELAIN DISPLACER 65.7 TITLE MODEL DIMENSION DRAWING 701, 703 NARROW DIFFERENTIAL SCALE 703 DrawingMODEL 0390671 EO NUMBER: 4441 Pneumatic SCALE 0.25 J REHM LOW ENGINEER APPROVAL R SAVERINO DATE 27 JUL 2011 IECEx Model 706/708 Flame Proof 2-1/2” NPT/Flanged Wide Differential N4 N7 B1 B2 DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 1” NPT JFIXSEN CHECKED BY JKENT ENGINEER APPROVAL SBOAL DATE 2/4/03 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE REV 0390670 ATEX Flame Proof/IS Model Name: 0390671_704.ASSEM/1/4+ 704 0.2 1 SHEET 1 OF 1 Model Name: 0390670.ASSEM/1/7+ Model 705/707 CHECKED BY DRAWING NUMBER SCALE: 0.25 DO NOT SCALE PRINT 2-1/2” NPT/Flanged Wide Differential K MITCHELL ACTUATION THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. MODEL 702 2.59 SCALE 0.2 W ISO-9001 DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN LOW 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM Housing** SWITCH 190.5 7.50 316 SST General Purpose DISPLACER Explosion Proof Explosion 63.5 Proof 2.50 Explosion Proof ACTUATION 63.5 2.50 65.7 2.59 70.6 2.78 77.0 3.03 86.6 3.41 62.7 2.47 64.3 2.53 4" HIGH 190.5 7.50 HIGH SWITCH ACTUATION 600 # 67.6 2.66 70.6 2.78 75.4 2.97 DIMENSION D MINIMUM 229 9.0 CABLE 195.6 7.70 300 # PROCESS Wide Differential Models 705-708: CONNECTION FLANGED Actuation differential is adjustable from approximately 9–1/2” 62.7 2.47 (minimum @ Specific Gravity of 1.0 @100°F) MINIMUM 3048 229 to available cable length. 120.0 9.0 ELECTRICAL CONN. "W" : __________ 6" 84.9 3.34 MINIMUM 229 9.0 FLANGE 150 # W 62.7 3" 2.47 DWG SIZE P1 B Reset Form T6 S3 w/CL S3 S8 DIM DWG 702, 704 NARROW DIFFERENTIAL (3) 1/4” NPT EO NUMBER: 4441 DRAWING NUMBER SCALE: 0.20 DO NOT SCALE PRINT REV 0390671 1 SHEET 1 OF 1 DWG SIZE B Reset Form M20 x 1.5*** * Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Switch Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials. Drawing 0390672 Form 912 (01.15) ©SOR Inc. Drawing 0390673 SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 35/60 730 Series Step 1: Model Series 731 A-F7A-B-A2-N4-CRTT The 730 Series mechanical liquid level switches are dual-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Select a model series from the charts below based on maximum operating pressure and minimum specific gravity. Maximum Working Pressure Model Series Minimum Specific Gravity 730 0.72 731 0.64 732 0.72 733 0.64 Function Connection Style NPT Narrow Differential 734 735 736 0.64 737 Wide Differential Connection Material 100°F (38°C) 450°F (232°C) Porcelain All 1000 (69) 750 (52) SS Flange Porcelain Flange SS NPT Pressure Rating - psig (bar) Displacer Material Porcelain SS Flange Porcelain Flange SS All 1000 (69) 750 (52) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) All 1000 (69) 750 (52) All 1000 (69) 750 (52) A105 285 (20) 185 (13) 316SS 275 (20) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) Displacer units are not available over 450oF (232oC). *An operating specific gravity is required for all 730 series at time of order. Step 2: Process Connection Material 731 A -F7A-B-A2-N4-CRTT Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. 36/60 Designator Material A A106 Carbon Steel fittings or flanges C A182-TP316/316L Stainless Steel fittings or flanges Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 730 Series Step 3: Process Connection 731 A -F7A-B-A2-N4-CRTT Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size Style 2-1/2” 3” 4” 6” Model 730 731 732 733 734 735 736 737 NPT F7A F7A - - F7A F7A - - NPT F3A F3A - - F3A F3A - - 150# RF Flange - - F3C F3C - - F3C F3C 300# RF Flange - - F3D F3D - - F3D F3D 150# RF Flange - - F4C F4C - - F4C F4C 300# RF Flange - - F4D F4D - - F4D F4D 150# RF Flange - - F6C F6C - - F6C F6C 300# RF Flange - - F6D F6D - - F6D F6D Step 4: Trim Material 731 A -F7A-B-A2-N4-CRTT Select the internal trim material from the chart below. Model Displacer Material Attraction Sleeve Construction Material 730 731 732 733 734 735 736 737 316/316L SS 400SS A only - B - B - B - B 316/316L SS 316/316L SS A or C - C - C - C - C Porcelain 400SS A only P - P - P - P - Porcelain 316/316L SS A or C R - R - R - R - Standard displacer spring material is Inconel 600. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 37/60 730 Series Unit Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.) Model 730/732 Model 731/733 2-1/2” NPT/Flanged Narrow Differential MODEL # 2-1/2” NPT/Flanged Narrow Differential SALES ORDER # MODEL # LINE ITEM # PURCHASE ORDER # SALES ORDER # *227.0 8.94 *227.0 8.94 *227.0 8.94 W W W W MINIMUM 229 9.0 MINIMUM MINIMUM 229 229 9.0 9.0 3048 3048120.0 120.0 316 SST 316 SST CABLE CABLE HIGH SWITCH ACTUATION HIGH HIGH 195.6 7.70 LOW SWITCH ACTUATION LOW Model Name: 0390672.ASSEM/1/6+ 65.7 2.59 Drawing 0390677 LOW HIGH 195.6 7.70 LOW SWITCH ACTUATION MODEL 730 SCALE 0.2 LOW HIGH SWITCH ACTUATION Model Name: 0390673.ASSEM/1/7+ LOW LOW SWITCH ACTUATION FLANGE PROCESS CONNECTION 600 # FLANGED 67.6 70.6 2.66 2.78 70.6 77.0 2.78 3.03 75.4 86.6 2.97 MINIMUM3.41 150 # 300 # 62.7 2.47 62.7 2.47 64.3 2.53 6" 3048 120.0 316 SST CABLE DIMENSION D 229 9.0 2-1/2 NPTM 3 NPTM General Purpose Explosion Proof LOW Explosion Proof LOW Explosion Proof 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 HIGH SWITCH PRODUCT CERTIFICATION DRAWING ACTUATION ALL DIMENSIONS ARE ±1/16 IN LOW SWITCHUNLESS OTHERWISE SPECIFIED MM LINEAR = ACTUATION IN DRAWN BY K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL Pneumatic 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 DRAWN BY 21 JUN 2011 P1 PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN TITLE MODEL 731 MODEL 732 SCALE 0.2 SCALE 0.2 DIMENSION DRAWING 730, 732 NARROW DIFFERENTIAL 63.5 2.50 65.7 2.59 DRAWING NUMBER 63.5 0390677 SCALE: 0.20 2.50 SHEET 1 OF MODEL 733 DO NOT SCALE PRINT SCALE 0.2 Drawing 0390678 Model 735/737 2-1/2” NPT/Flanged Wide Differential 2-1/2” NPT/Flanged Wide Differential Drawing 0390679 Drawing 0390680 Registered Quality System to ISO 9001 JFIXSEN CHECKED BY JKENT ENGINEER APPROVAL (3) 1/4” NPT SBOAL DATE 2/4/03 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. T6 S3 w/ CL TITLE ATEX Flame Proof/IS EO NUMBER: 5090 Flame Proof 38/60 N4ELECTRICAL CONN. "W" : __________ N7 1” NPT B1 B2 DATE THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. LOW W J FIFE IECEx Model 734/736 84.9 3.34 87.9 Housing** 3.46 HIGH 146.1 * MINIMUM OVERHEAD CLEARANCE 5.75 316 SST REQUIRED TO REMOVE HOUSING COVER DISPLACER HIGH DISPLACER LOW 146.1 OVERHEAD CLEARANCE REQUIRED 5.75 TO REMOVE HOUSING COVER. * MINIMUM DIMENSION C 3" 316 SST DISPLACER PORCELAIN HIGH PORCELAIN DISPLACER HIGH SWITCH ACTUATION SEE CHART SIZE 62.7 2.47 HIGH HIGH SEE CHART DIMENSION D 4" 84.9 3.34 PURCHASE ORDER # NPT A 180.9 7.12 FLANGE B 101.6 4.00 DIMENSION C ELECTRICAL CONNECTION W 2-1/2 NPT(M) PROCESS CONNECTION FLANGE B PROCESS CONNECTION NPT A 3048 120.0 316 SST CABLE *227.0 8.94 PROCESS C CONNECTION D 1 SALES PAGE LINE ITEM # 180.9 180.9 7.12 7.12 101.6 101.6 4.00 4.00 180.9 7.12 101.6 4.00 1 REV 3 DWG SIZE B Reset Form DIM DWG 731, 733 NARROW DIFFERENTIAL EO NUMBER: 4441 SCALE: 0.20 DO NOT SCALE PRINT S3 S8 DRAWING NUMBER 0390678 REV 1 M20 x 1.5***Reset Form SHEET 1 OF 1 DWG SIZE B * Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover. ** See Switch Housing section (page 48). *** M20 adapters are brass. Contact the factory for alternate materials. | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 730 Series Specific Gravity Ranges Optional Switching Arrangements Dual-stage, wide differential switches may be ordered with switching arrangements different from those shown on page 38. To order, select the desired arrangement below and add SC to the accessory section of the model number. At the time of order, specify the required arrangement number. Porcelain displacers are shown for pictorial purposes only. Arrangement 1 Arrangement 2 Arrangement 4 Arrangement 5 Arrangement 6 Switch Position Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 39/60 750 Series Step 1: Model Series 751 A-F7A-B-A3-N1-CRTT The 750 Series mechanical level switches are three-stage, displacer-operated switches suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching elements, housings and accessories. Maximum Working Pressure Model Series Minimum Specific Gravity 750 0.96 751 0.85 752 0.96 753 0.85 754 0.96 755 0.95 756 0.96 757 0.95 Function Connection Style NPT Narrow Differential Wide Differential Connection Material 100°F (38°C) 450°F (232°C) Porcelain All 1000 (69) 750 (52) SS All 1000 (69) 750 (52) Flange Porcelain Flange SS NPT Pressure Rating - psig (bar) Displacer Material A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) Porcelain All 1000 (69) 750 (52) SS All 1000 (69) 750 (52) Flange Porcelain Flange SS A105 285 (20) 185 (13) 316SS 275 (20) 182 (13) A105 285 (20) 185 (13) 316SS 275 (19) 182 (13) Displacer units are not available over 450oF (232oC). *An operating specific gravity is required for all 750 series at time of order. Step 2: Process Connection Material 751 A -F7A-B-A3-N1-CRTT Select a process connection material from the chart below. Maximum working pressure in the chart above is based on the material selected here. Consult the factory for alternative materials. 40/60 Designator Material A A105 Carbon Steel fittings or flanges C A182-TP316/316L Stainless Steel fittings or flanges Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 750 Series Step 3: Process Connection 751A -F7A-B-A3-N1-CRTT Select a process connection style, size and rating from the chart below. Consult the factory for variations. Flanged process connections may reduce the maximum working pressure of the unit. Size Style 2-1/2” 3” 4” 6” Model 750 751 752 753 754 755 756 757 NPT F7A F7A - - F7A F7A - - NPT F3A F3A - - F3A F3A - - 150# RF Flange - - F3C F3C - - F3C F3C 300# RF Flange - - F3D F3D - - F3D F3D 150# RF Flange - - F4C F4C - - F4C F4C 300# RF Flange - - F4D F4D - - F4D F4D 150# RF Flange - - F6C F6C - - F6C F6C 300# RF Flange - - F6D F6D - - F6D F6D Step 4: Trim Material 751 A -F7A-B-A3-N1-CRTT Select the internal trim material from the chart below. Model Displacer Material Attraction Sleeve Construction Material 750 751 752 753 754 755 756 757 316/316L SS 400SS A only - B - B - B - B 316/316L SS 316/316L SS A or C - C - C - C - C Porcelain 400SS A only P - P - P - P - Porcelain 316/316L SS A or C R - R - R - R - Standard displacer spring material is Inconel 600. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 41/60 750 Series Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches. (Linear = mm/in.) Model 750/752 2-1/2” NPT/Flanged Model 751/753 2-1/2” NPT/Flanged Model 754/756 2-1/2” NPT/Flanged Model 755/757 2-1/2” NPT/Flanged 1 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # NPT A 180.9 7.12 180.9 7.12 FLANGE B 101.6 4.00 101.6 4.00 W W PROCESS CONNECTION NPT A D 3048 120.0 316 SST CABLE PROCESS CONNECTION FLANGE B DIMENSION C 3" 4" MINIMUM 229 9.0 3048 120.0 316 SST CABLE HIGH SEE CHART SIZE C MINIMUM 229 9.0 SEE CHART ELECTRICAL CONNECTION W *306.4 12.06 *306.4 12.06 DIMENSION C DIMENSION D 6" FLANGE 150 # 300 # 600 # 62.7 2.47 62.7 2.47 64.3 2.53 67.6 2.66 70.6 2.78 75.4 2.97 70.6 2.78 77.0 3.03 86.6 3.41 DIMENSION D HIGH 84.9 3.34 87.9 3.46 2-1/2 NPTM 3 NPTM TOP SWITCH ACTUATION LOW TOP SWITCH ACTUATION HIGH 316 SST DISPLACER MIDDLE SWITCH ACTUATION LOW HIGH 316 SST DISPLACER LOW 63.5 2.50 MODEL 751 SCALE 0.15 Drawing 0390681 Drawing 0390682 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM LOW DRAWN BY HIGH 190.5 7.50 BOTTOM SWITCH ACTUATION 222.3 OVERHEAD CLEARANCE 8.75 REQUIRED TO REMOVE HOUSING COVER * MINIMUM ISO-9001 MIDDLE SWITCH ACTUATION HIGH LOW 190.5 7.50 BOTTOM SWITCH ACTUATION PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 63.5 2.50 MODEL 753 SCALE 0.15 R SAVERINO DATE Drawing 0390683 DIMENSION DRAWING 751, 753 NARROW DIFFERENTIAL Drawing 0390684 EO NUMBER: 5123 SCALE: 0.15 DRAWING NUMBER REV 0390682 3 SHEET 1 OF 1 DWG SIZE B Reset Form W 1” NPT ** See Switch Housing section (Page 48). 42/60 ENGINEER APPROVAL TITLE * Minimum 8-3/4’’ (222 mm) overhead clearance required to remove housing cover. B5 N1 N8 J REHM THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. Model Name: 0390682.ASSEM/2/0 Housing** CHECKED BY 27 JUL 2011 LOW DO NOT SCALE PRINT Explosion Proof General Purpose Explosion Proof K MITCHELL Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. 750 Series Specific Gravity Ranges Optional Switching Arrangements Three-stage, wide differential switches may be ordered with switching arrangements different from those shown on page 42. To order, select the desired arrangement below and add SC to the accessory section of the model number. At the time of order, specify the required arrangement number. Porcelain displacers are shown for pictorial purposes only. Arrangement B Arrangement C Arrangement G Form 912 (01.15) ©SOR Inc. Arrangement D Arrangement H SORInc.com Arrangement E Arrangement F Switch Position | 913-888-2630 | Registered Quality System to ISO 9001 43/60 Level Switches Switching Mechanisms SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a variety of electrical and pneumatic switching mechanism types to fit a wide range of applications. The basic types of switch mechanisms available are listed below. See page 47 for specifications. All SOR switching mechanisms are constructed from stainless steel and other durable manufactured materials. Each mechanism is individually calibrated and inspected to insure accuracy and repeatability. See below for the benefits and application of each switch type. All mechanisms are interchangeable with most competitor units. Standard Dry-Contact Switches Types A, B, C, E Standard dry-contact switches have open mechanisms and exposed switching elements. These switching mechanisms are easy to maintain. Visual confirmation of operation is obvious. Dry-contact switch mechanisms are recommended for most level switch applications and are available in SPDT and DPDT switch arrangements. Dry-Contact Switch Mechanisms feature: • High-load carrying capacity • High-quality phenolic insulator • Vibration resistance • Versatility of application Mini-Hermetically Sealed Switches Types L, S, T, V Mini-hermetically sealed switches have a hermetically sealed switch element on an exposed mechanism. Good for hightemperature service and normal applications that require hermetically sealed contacts. Mini-Hermetically Sealed Switch Mechanisms feature: • Rugged stainless steel construction • Class I Group A rating for use in hazardous areas • Vibration resistance • High operating temperature limits Anti-Vibration Switches Types D and R Anti-Vibration Switches employ two magnets to provide vibration protection. Dual magnets prevent false trips by providing a positive mechanical lock to the enclosing tube when the switch is in any position. (Type T switches are mini-hermetically sealed units with dual magnets.) 44/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Switching Mechanisms Pneumatic Switch Type J Pneumatic switches are available for applications that prohibit electrical switching or where electricity is not available. Pneumatic switches feature: • Three-way aluminum valve • Anti-vibration design • 1/4" NPT ports in 316SS for additional corrosion resistance Extra-High Temperature Switch Type Y The Y Series level switch mechanism is designed to operate normally under extremely high-temperature conditions. Constructed of stainless steel, ceramic, and oxidation-resistant alloys, the Y Series is designed to counteract the warping and seizure normally associated with this type of mechanism in high temperatures. The Y Series switch is especially well suited for power plant conditions. Y Series Switch Mechanisms feature: • Mica/glass insulation on wires and switches • Stainless steel and ceramic switch element and terminal block • Switch mechanism rated at 800°F (427°C) continuous process temperature • Can be combined with external temperature protection to function in temperatures up to 1200°F (649°C) • Dual magnets for vibration protection Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 45/60 Level Switches Switching Mechanisms 741A -A1C-B-A1-N4-CRTT Select the switch mechanism from the chart below. 1 Single A3 B3 C3 A4 B4 C4 A5 B5 C5 A8 B8 C8 - l l l l l l l l l 1 Switch Designator A1 B1 C1 1 A2 B2 C2 l l l l l l l Rostechnadzor (RTN) Triple INMETRO (IS) Dual INMETRO (flameproof) Standard Dry Contact High-Temperature Dry Contact Gold Contact Single IECEx Switching Description Triple ATEX (flameproof) Dual Available Agency Listings UL Single 3-Way Valve CSA Switching Stages DPDT Double Pole Double Throw ATEX (IS) SPDT Single Pole Double Throw Switch Type l l l l Anti-Vibration Dry Contact High-Amperage DC Service D1 E1 E2 E3 D4 E4 E5 E8 - l l l l l l l l l l l l Standard Mini-Hermetically Sealed L1 L2 L3 L4 L5 L8 - l l l l l l Anti-Vibration Gold Contact1 R11 - - R41 - - - l l l l l l l l Gold Contact Mini-Hermet Anti-Vibration Mini-Hermet1 High-Temperature Mini-Hermet S1 T11 V1 S2 V2 S3 V3 S4 T41 V4 S5 V5 S8 V8 - l l l l l l l l l l l l l l l l l l Extra-High Temperature (Ceramic) Pneumatic Non-Bleed with 316SS Fittings Y11 - - - Y41 - - - J01,2 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Available with models: Series 100-200-300-740-800 Series 108/208-400 Series 700 Series 730 Series 750 (enclosures N1, N8 or B5 only) l l l l Notes 1. These switches use two magnets and must be considered dual mechanisms when figuring minimum specific gravity. 2. Pneumatic switching mechanisms must be specified with P1 housing. 46/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Switch Ratings 210-250VAC 20-30VDC 110-130VDC 210-250VDC 110-130VAC 210-250VAC 20-30VDC 110-130VDC 210-250VDC Inductive Amperage 110-130VAC Resistive Amperage A Standard Dry Contact 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C) B Hi-Temperature Dry Contact 5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C) C Gold Contact 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C) D Anti-Vibration 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C) E High-Amp DC - - 10 10 3 - - 10 10 3 -15°F (-26°C) 250°F (121°C) L5 MiniHermetically Sealed DPDT 5 5 5 .5 - 5 5 2.5 .25 - SPDT 11 11 5 .5 .25 11 11 2.5 .25 .13 -15°F (-26°C) 250°F (121°C) R Anti-Vibration Gold Contact 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C) S Gold Contact Mini-Hermet 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C) T5 Anti-Vibration Mini-Hermet 5 5 5 .5 - 5 5 2.5 .25 - -15°F (-26°C) 250°F (121°C) (-26°C) 250°F (121°C) V Y6 Switch Designator J4 DPDT Minimum Temperature1 Maximum Temperature2 11 11 5 .5 .25 11 11 2.5 .5 .13 -15°F High-Temperature Mini-Hermet 5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C) Extra-High Temperature (Ceramic) 1 1 1 .4 - 1 1 .4 - - -40°F (-40°C) 800°F (427°C) 5°F (-15°C) 200°F (93°C) SPDT Pneumatic 316SS Fittings Non-bleed 3-way aluminum valve body. Buna-N O-Rings 150 psi maximum supply, 24CFM @ 100 psi Note 3 Notes 1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary according to actual climatic conditions. Actual minimum process temperature may be much lower. Consult the factory for details. 2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased according to the type of process. Refer to pages 51 - 52 for more details. 3. -40°F Temperature rating with no icing. 4. Pneumatic switches must be used with clean, dry air or gas. 5. These switch designators have higher current rating for SPDT than DPDT. 6. Manufacturer specifications state maximum operating humidity must be <85% and minimum power rating is 100mW. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 47/60 Level Switches Housings 741A -A1C-B-A1-N4-CRTT SOR housings are designed to protect the switching mechanisms from harsh environmental conditions, as well as protecting the surrounding atmosphere from potential ignition sources. The basic types of housings are listed below. General Purpose, NEMA 4 Housings are heavy duty cast aluminum. All housings are rated NEMA 4 (IP65) as a minimum. Explosion-Proof Housings are available in aluminum or cast iron. Explosion-Proof ratings include Class I, Group B, C, D; Division 1 & 2, and Ex d IIC T6 Gb (ATEX) and Ex d IIC T6 (IECEx). Pneumatic Switch Housings are required for use with a pneumatic switching mechanism. These enclosures are General Purpose, NEMA 4 (IP65) only. NEMA 4X Housings are standard in aluminum. Cast iron enclosures can be rated NEMA 4X by adding epoxy coating. Switch Housings Select the housings from the chart below. Available with Models 108, 208, 400 740, 800 700’s 730’s £ £ £ £ £ £ £ £ B2 Cast Iron Groups B, C, & D £ £ £ £ £ £ £ £ B5 Aluminum Extended Groups B, C, & D £ £ £ N1 Aluminum Extended NEMA 4, 4X £ £ £ N4 Aluminum NEMA 4, 4X £ N6 Cast Iron Double Hub Groups C & D £ N7 Aluminum Groups C & D £ N8 Aluminum Extended Groups C & D £ P1 Aluminum Pneumatic NEMA 4, 4X S3 Aluminum Ex d IIC T6 (IECEx) Ex d IIC T6 Gb (ATEX) Ex ia IIC T6 Gb (ATEX) S82 Cast Iron Ex d IIC T6 (IECEx) T62 Cast Iron Ex d IIC T6 Gb(ATEX) Ex ia IIC T6 Gb (ATEX) 2 2 1 ATEX Enclosure Rating2 £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ £ n 750’s 100, 200, 300 Groups B, C, & D B1 Description INMETRO UL Aluminum Designator TestSafe CSA Rostechnadzor Agencies £ n £ £ n £ £ £ £ £ £ £ £ £ £ £ £ — Available — Standard (Agency listing accessory designator is not needed.) 1. P1 housing must be used with pneumatic switch mechanisms. 2. All cast iron housings can be rated NEMA 4X by adding PY to the accessory section of the model number. 48/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Accessories 741A -A1C-B-A1-N4-CRTT SOR accessories are provided for customizing the level switches in this catalog according to the requirements of the application. Place accessory designator(s) from the table below at the end of the model number. Check the compatibility chart below for correct use of each accessory. Accessory Compatibility Chart Model Series Description 100 200 108/ 208 300 400 741-743 802 740 804 700 730 750 AF1 FE CL Air Filter & Gauge Finned Extention ATEX Approved for S3 Hsg l l l l l l l l l l l l l l l l l l l l l CN7 CP7 CR7 Conduit Reducer M20 x 1.5 Conduit Reducer 1/2” NPT Conduit Reducer 3/4” NPT CS2 CV CY CSA Certification Canadian Registration Number (CRN) Certificate of Conformance (power plant piping, ANSI 31.1) l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l CZ3 l l l l l l DN EC8 Certificate of Conformance (petrochemical piping, ANSI 31.3) Special Drain Connection Extra Chamber Connection l C/F l C/F C/F l C/F l C/F ET5 FE GG Temperature Extension Finned Extention Sealed Conduit l l l l l l l l l l l l l l l l l l l l l l l ID KK MC4 Interface Detection Housing Breather Drain Manual Check l l l l l l l l l l l l l l l l l MR MT NC NM Mill Test Report Mag Particle Examination NACE Construction INMETRO Approved for S3 Hsg l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l PP PT PY l l l l l l l l l l l l l l l l l l l l l l l l l l RR Fiber Tag Dye Penetration Examination Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hrs. salt spray) SS Tag wired to housing l l l l l l l l l l RT SC10 SD11 Radiograph Examination Special Calibration Special Dimensions l C/F C/F l C/F C/F l C/F C/F C/F l C/F l C/F C/F l C/F C/F C/F C/F C/F SL12 TC4 Special Cable Length Tru-Check l l l l l TF TT Tandem Floats Oversized Nameplate for customer tagging C/F l C/F l l UT VV WC WV2 Ultrasonic Examination Fungicidal Varnish Water Column Unit UL Listed l l C/F l l l YY Epoxy Coating (enclosure only) l 9 Notes 1. 2. 3. 4. 5. C/F = Consult the Factory Pneumatic switching mechanisms only (P1) Consult switch and housing sections for agency availability. Process media must be known prior to manufacture. Different processes (service categories) require different quality inspection procedures. Consult the factory for details. Appropriate for Model Series 701 through 704 and 730 through 733. See page 55 for details. Not available with NACE. See high-temperature selection for application. Form 912 (01.15) ©SOR Inc. SORInc.com l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l 6. Not available with agency-listed housings. 7. Not available with T6 and S3 (ATEX) housings. 8. Need connection size, type, and location on chamber. 9. The upper and lower specific gravity required to determine functionality. 10. Operating specific gravity, Set Point (referenced from upper process connection) and if Set Point is rising or falling are required. 11. Specific details of chamber dimensional changes. 12. Length of cable required (10 ft. is standard). | 913-888-2630 | Registered Quality System to ISO 9001 49/60 Level Switches Test Certificates Float Operated Switches Certificates C1 Series 100 Calibration ¿ Series 200 Hydrostatic Pressure Test Series 220 Inspection Report Series 300 Compliance / Conformance Series 400 Series 108/208 C2 C3 C4 C5 C6 C7 ¿ ¿ B2 B3 B5 B6 B7 A2 A3 A4 A7 A8 A9 ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ Dielectric Test ¿ ¿ ¿ ¿ Insulation Resistance ¿ ¿ ¿ ¿ ¿ ¿ ¿ QA Test Report ¿ ¿ ¿ ¿ ¿ ¿ ¿ Displacer Operated Switches Series 700, 730, 750 Certificates C1 Calibration ¿ Inspection Report C3 C4 C5 C6 C7 ¿ *Series 740 Compliance / Conformance *Series 800 Dielectric Test B5 B6 B7 ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ Insulation Resistance QA Test Report ¿ ¿ ¿ ¿ ¿ *These products also have Certificate C2 - Hydrostatic Pressure Test. 50/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches High Temperature Selection SOR level switches can accommodate high-temperature applications up to 1200oF (649oC). These temperatures may be safely reached by a proper combination of chamber material, switch mechanism and temperature extension. Refer to page 52 to select the proper components for your process temperature. DRAWING NUMBER 03 ET Accessory MODEL # PURCHASE ORDER # The straight temperature extension provides physical distance between the process and the switching mechanism. It is constructed of a straight piece of pipe welded between the chamber and enclosing tube connection. SALES ORDER # 201 A -A1C-B-A1-N4-ET TT 146.1 O 5.75 REQUIRED TO REM * MINIMUM 180.9 7.12 101.6 4.00 How It Works The straight temperature extension is designed to remove the switch from direct radiant heat in dry heat processes. Consult the chart on page 52 for application. *228.6 9.00 SWITCH ENCLOSURE 14685 W To Specify Add Accessory Designator ET to the end of the SOR level switch model number per the selection chart on the next page. ISO-9001 W TEMPERATURE EXTENSION The ET accessory automatically matches the material and rating of the specified level switch chamber. This option can be supplied on SOR level switches Series 100, 200, 300 and 400. LINEAR = THIS DRAWING IS T NO USE WHATSOEVER HEREON, NOR REPROD MADE WITHOUT THE EX CHAMBER/PROCESS CONNECTION Drawing 0390676 FE Accessories PRODUCT CERTIFICA ALL DIMENSIONS UNLESS OTHERWI TITLE DIM DWG STRAIGHT TE EO NUMBER: 5090 SCALE: DRAWING SCAL DO NOT SCALE PRINT Model Name: MODEL NAME.DRAFT/2/1+ 201 A -A1C-B-A1-N4-FE TT The finned temperature extension is designed to protect the electrical portion of a level switch from heat damage due to condensing processes. When used in combination with high-temperature switch mechanisms, this option allows operation in process temperatures up to 1200oF (649oC). How It Works The finned temperature extension condenses process steam and reduces its heat before it can reach the switching mechanism. The design reduces steam to its saturation temperature in the enclosing tube, protecting the switching mechanism from deterioration due to high temperatures. The process pressure dictates the saturation temperature, see page 57. To Specify Add Accessory Designator FE to the end of the SOR level switch model number per the selection chart on the next page. The finned temp. extension automatically matches the material and rating of the specified level switch chamber. These options can be supplied on SOR level switches series 100, 200,108/208, 300 and 400. Note: For proper cooling, temp. extensions must not be insulated or placed inside an enclosed structure. High ambient temperatures (over 100oF/38oC), intense direct sunlight, or heat loading from adjacent piping or vessels will affect cooling performance. Consult the factory if any of these conditions exist. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 51/60 Level Switches High Temperature Selection There are two sections to the chart, Steam Heat and Dry Heat. Fundamental differences in condensing (steam) and non-condensing (dry) heat require different methods of protection. Steam Heat processes carry it’s heat with the vapor. These processes effectively heat every portion of their enclosure. To reduce the heat effects of condensing processes, we must either condense or physically block the vapor. SOR uses a condensing system to avoid the sealing problems associated with blocking the steam. Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where they touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may be resolved by adding distance between the process and the protected portion of the control. To use the selection chart, first select the column that represents the desired maximum temperature. Select a chamber material that is allowable in the chosen column. Move down to the proper process type section, Steam Heat or Dry Heat. Within that section, select a switch mechanism from those listed in the chosen column. The symbol will indicate if a temperature reduction device is required. ­ ­­­­­­­­­­ ≤ 1200oF (649 oC) ­ ­­­­­­­­­­ ≤ 1150oF (621oC) ­ ­­­­­­­­­­ ≤ 1100oF (593oC) ­­­­­­­­­­­ ≤ 1050oF (566oC) ­ ­­­­­­­­­­­ ≤ 1000oF (538oC) ­ ­­­­­­­­­­­ ≤ 950oF (510oC) ≤ 700oF (371oC) ­ ­­­­­­­­­­­ ≤ 900oF (482oC) ≤ 650oF (343oC) ­ ­­­­­­­­­­­ ≤ 850oF (454oC) ≤ 600oF(316oC) ­ ­­­­­­­­­­­ ≤ 800oF (427oC) ≤ 550oF (288oC) ­ ­­­­­­­­­­­ ≤ 750oF (399oC) ≤ 500oF (260oC) A106B Carbon Steel 304/304LSS 316/316LSS ≤ 450oF (232oC) Chamber Material (Select one) 0-400oF (204oC) Features Designator High Temperature Selection Chart A C A333 GR.6 A335-P11 Chrome Moly A335-P91 Hastelloy C Alloy-20 Monel-400 ­ ­ ­­­­­­­­­­­­ ­­­­­­­­­­­ ­ ­­­­­­­­­­­ ­ ­­­­­­­­­­­ ­ ­­­­­­­­­­­ ­ ­ ­­­­­­­­­­­ ­­­­­­­­­­­­ ­ ­­­­­­­­­­­ ­­­­­­­­­­ n n v v v v n n l l l l ­ ­­­­­­­­­­­­ ­­­­­­­­­­­ Steam Heat Applications Switch Mechanism (Select one) Hi-Temp Dry Contact or Mini-Hermet Hi-Temperature Ceramic/SS B/V n l l v v Y n n n n n n n v v v v Dry Heat Applications Switch Mechanism (Select one) Hi-Temp Mini-Hermet or Dry Contact Hi-Temperature Ceramic/SS B/V n l l l l Y n n n n n n n For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed structure. High ambient temperatures (over 100ºF/38ºC), intense direct sunlight or heat loading from adjacent piping or vessels will affect cooling performance. Consult the factory if any of these conditions exist. n = Switch Only 52/60 v = Finned Extension Registered Quality System to ISO 9001 l = Temperature Extension | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches High Temperature Selection Model Material 500°F (260°C) 550°F (288°C) 600°F (316°C) 650°F (343°C) 700°F (371°C) 750°F (399°C) 101 CS & SS 170 155 140 125 110 95 102 CS & SS 447 435 423 411 400 389 103 CS SS 600 480 575 465 550 450 535 445 535 430 505 425 104 CS & SS 894 870 846 823 800 778 108 CS SS 600 480 575 465 550 450 535 445 535 430 505 425 109 CS & SS 170 155 140 125 110 95 121 CS & SS 170 155 140 125 110 95 122 CS & SS 313 304 296 288 280 272 201 CS & SS 201 196 190 185 180 175 202 CS & SS 268 261 254 247 240 233 203 CS & SS 447 435 423 411 400 389 204 CS & SS 1118 1087 1057 1029 1000 972 205 CS & SS 671 652 634 617 600 584 206 CS & SS 894 870 846 823 800 778 207 CS & SS 894 870 846 823 800 778 208 CS SS 1794 1495 1794 1453 1794 1411 1794 1387 1722 1351 1554 1339 209 CS & SS 403 391 381 370 360 350 221 CS & SS 313 304 296 288 280 272 Form 912 (01.15) ©SOR Inc. SORInc.com Higher temperatures available with other materials. Consult with the factory. Float Switch Pressure Ratings (in psi) above 450°F (232°C) | 913-888-2630 | Registered Quality System to ISO 9001 53/60 Examination and Testing Requirements 741A -A1C-B-A1-CYCRTT Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance. Designator Certificate of Conformance to CY ASME/ANSI B31.1 Power Piping CZ ASME/ANSI B31.3 Petrochemical Piping If certification to B31.3 is required, SOR, Inc. must know the fluid category per the chart below. Read the ASME/ANSI B31.3 Fluid Category Section at the bottom of this page to determine the applicable category. Units Covered Visual Examination1 Radiographic (X-Ray) RT Magnetic Particle MT Dye Penetrant PT Hydrotest 0% 1.5 x pressure for 3 minutes Standard Inspection All Chambers 100% 0% 0% CY Option (ASME/ANSI B31.1) Below 750°F Below 1025 psi 100% - - - Below 350°F All pressures 100% - - - 350°F - 750°F Above 1025 psi 100% All butt welds >2” - - Above 750°F All pressures 100% All butt welds >2” Butt welds >2” all other welds Butt welds >2” all other welds CZ Option (ASME/ANSI B31.3) 5%2 - 1.5 x pressure for 10 minutes Normal Fluid 5% - Category D Engineering/QA Choice - - - Category M 100% 20% of all welds3 - - Severe Cyclic 100% in place of RT 100% of all butt welds+ MT of welds excluded @ RT MT of welds excluded @ RT High Pressure 100% 100% of girth/ branch welds - - 1.5 x pressure for 10 minutes Notes 1. In process visual inspection: inspecting pipe bevel prior to welding, check fit-up, check after-tack weld, and check during weld passes. After completion visual inspection: welding and grinding is checked. 2. In process examination may be substituted on a weld-for-weld basis. 3. In process examination supplemented by appropriate NDE (MT or PT) may be substituted on a weld-for-weld basis. ANSI/ASME B31.3 Fluid Category Normal A fluid service not subject to the following four categories. Category D A fluid service in which all of the following apply: 1. The fluid handled is non-flammable, non-toxic, and not damaging to human skin. 2. The design gage pressure does not exceed 150 psi. 3. The design temperature is between -20°F and 366°F. Category M A fluid service in which the potential for personnel exposure is judged to be significant and in which a single exposure to a very small quantity of a toxic fluid, caused by leakage, can produce serious irreversible harm to persons on breathing or bodily contact, even when prompt restorative measures are taken. Severe Cyclic A fluid service with high-cycle rates that cause extreme stress on components. High Pressure Pressure in excess of that allowed by the ASME B16.5 Class 2500 rating for the specified temperature and material group or any piping so designated by the customer. 54/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches MC and TC Options 702A-AIC-B-A1-MC-CRTT Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top of the tank. Specify either an MC or TC option by placing the designator in the accessory section of the model number. Designator Application TC Tanks or vessels pressurized to 100 psi MC Atmospheric vented tanks or vessels These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high and low SG values. Please consult factory before ordering the MC or TC options for these models. How It Works Pulling the handle transfers downward motion to the actuator lever by means of the beaded stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves the attraction sleeve and actuates the switching element to simulate a high-level condition. Switching action for alarm, shutdown or control is verified. Dimensions SALES ORDER # 101.6 4.00 LINE ITEM # PURCHASE ORDER # Product Specifications 393.7 15.50 Pressure Range W TC (Tru-Check) MC (Manual Check) 0 psi (vented to atmosphere) *0 to 100 psi *Maximum pressure for entire level sensing assembly *456.4 17.97 is 100 psi with Tru-Check installed. 229.4 9.03 Temperature Range -40 to 300°F (–40 to 150°C) Wetted Parts PROCESS CONNECTION 2-1/2 NPTM OR 4" 150# FLANGE (NOT SHOWN) Ball Chrome Plated Brass Seal Spring Body Teflon Spring Steel 146.1 OVERHEAD CLEARANCE 5.75 1018COVER Steel REQUIRED TO REMOVE HOUSING * MINIMUM ELECTRICAL Design and specifications are subject to change CONNECTION "W" without notice. For latest revision, see www.sorinc.com. 14685 W 105TH ST LENEXA, KS 66215 USA CUSTOMER SPECIFIED DIMENSION 316 SST CABLE ISO-9001 HANDLE 913-888-2630 SORINC.COM DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL J FIFE DATE 16 MAY 2011 DISPLACER THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE DIM DWG 700 SERIES W/MANUAL CHECK EO NUMBER: 5116 Drawing 0390674 SCALE: 0.20 DO NOT SCALE PRINT 74.ASSEM/1/5+ DRAWING NUMBER REV 0390674 3 SHEET 1 OF 1 DWG SIZE B Reset Form Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 55/60 Level Switches ASTM Material Designations SOR uses all ASTM grade materials in the construction of mechanical level switches. The following chart lists the specific ASTM (or UNS) materials that are normally used for each component in our switches. Consult the factory if you do not see the specific material required for your application. ANSI B36.10 ANSI B16.9 ANSI B36.10 ANSI B16.5 Seamless Pipe Butt Weld Fitting Screwed/Socket Fitting Flanges Temperature Range Carbon Steel A106B A234-WPB A105 A105 -20°F to 800°F 304/304LSS A312-T304 A403-WP304 A182-F304 A182-F304 -425°F to 750°F A312-T316 A403-WP316 A182-F316 A182-F316 -325°F to 750°F Low Temperature Carbon Steel A333 Gr. 6 A420-WPL6 A350-LF2 A350-LF2 -50°F to 700°F 1-1/4% Chrome2 1/2% Moly A335-P11 A234-WPL11 A182-F11 A182-F11 -20°F to 1100°F Hastelloy-C2762 N10276 B6221 B366/B564 B366/B564 B366/B564 -325°F to 800°F Alloy-202 N08020 B4641 B366/B962 B366/B462 B366/B462 -325°F to 800°F Monel 4002 N04400 B-1651 B366/B564 B366/B564 B366/B564 -325°F to 900°F A-790 A-815 A182-F51 A182-F51 -60°F to 600°F 2-1/4% Chrome 1% Moly A335-P22 A335-P22 A182-F22 A182-F22 -20°F to 1100°F 9% Chrome 1% Moly Vanadium A335-P91 A234-WP91 A182-F91 A182-F91 -20°F to 1200°F Material 2 316/316LSS 2 Duplex SS2 2 Notes 1. UNS numbers are given in parenthesis for special alloys. 2. These materials are available by special order only. Flange Face Finishes The most common flange face finishes are shown. SOR standard flange finishes are highlighted. Raised Face Flanges (RF) All raised-face flange finishes are given as a range. AARH (Average Arithmetic Root Height) values are given with their metric equivalent. AARH (µin.) 1000-2000 500-1000 250-500 125-250 63-125 32-63 16-32 Ra (µm) 25-50 12.5-25 6.3-12.5 3.2-6.3 1.6-3.2 0.8-1.6 0.4-0.8 Ring Tight Joint Flanges (RTJ) The side surfaces of RTJ gasket surfaces shall not exceed 63µ” (1.6µm) roughness per ANSI B16.5. 56/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Specific Gravity of Water The specific gravity of water changes depending on its temperature and pressure. The chart below lists properties of saturated steam. Saturated steam is the state where water is in transition between liquid and vapor. The chart provides the process temperature with the associated pressure and specific gravity of the condensate water. If a water application has a high temperature and low pressure, condensate will only be present at the temperature that corresponds to the maximum pressure. Select the proper row based on the temperature and pressure, and read the specific gravity. Figures are based on saturated steam. Boiling Temperature F° Vacuum Inches Hg Specific Gravity Boiling Temperature F° Pressure psig Specific Gravity Boiling Temperature F° Pressure psig Specific Gravity 32 29.74 .9999 212 0.0 .96 450 407.0 .82 40 29.67 1.0000 220 2.49 .96 460 451.2 .81 50 29.56 .9997 230 6.08 .95 470 498.8 .80 60 29.40 .9990 240 10.27 .95 480 550.1 .80 70 29.18 .9980 250 15.13 .94 490 605.2 .79 80 28.89 .9966 260 20.14 .94 500 664.3 .78 90 28.50 .9950 270 27.17 .93 510 728.3 .77 100 27.99 .9931 280 34.52 .93 520 795.3 .76 110 27.33 .9909 290 42.87 .92 530 868.3 .76 .9886 300 52.30 .92 540 945.3 .74 63.00 .91 550 1028.3 .73 120 26.48 130 25.40 .9860 310 140 24.04 .9832 320 75.00 .91 560 1116.3 .71 150 22.35 .9803 330 89.3 .91 570 1209.3 .70 160 20.27 .9772 340 103.3 .90 580 1308.3 .69 170 17.72 .9730 350 119.9 .89 590 1414.3 .68 180 14.63 .9704 360 138.3 .88 600 1529.3 .67 190 10.91 .9668 370 158.5 .88 610 1644.3 .66 200 6.46 .9631 380 180.9 .87 620 1769.3 .65 210 1.17 .9592 390 205.4 .86 630 1902.3 .63 400 232.3 .86 640 2042.3 .62 410 261.6 .85 650 2190.3 .60 Form 912 (01.15) ©SOR Inc. 420 293.4 .84 660 2346.3 .58 430 328.4 .84 670 2511.3 .56 440 366.2 .83 680 2690 .49 690 2883 .48 700 3075 .44 705 3189 .32 SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 57/60 Level Switches Conversions General English-to-Metric unit conversions are listed below. Pressure To Convert from: Bar Kilo Pascals (kPa) Mega Pascals (MPa) Kilograms per cm2 (kg/cm2) Pounds per Square Inch (psi) Pounds per Square Inch (psi) Pounds per Square Inch (psi) Pounds per Square Inch (psi) Specific Gravity To Convert from: Kilograms per meter3 (kg/m3) Pounds per foot3 (lb/ft3) Degrees API Specific Gravity (SG) Specific Gravity (SG) Specific Gravity (SG) Length To Convert from: millimeters (mm) meters (m) Inches (in.) Feet (ft.) Temperature To Convert from: Degrees Fahrenheit (°F) Degrees Centigrade (°C) Fluid Flow Rates To Convert from: Feet per Second (FPS) Kilograms per Hour (kg/H) Meters per Second (m/s) Cubic meters per Hour (m3/hr) Gallons per Minute (GPM) Gallons per Minute (GPM) Gallons per Minute (GPM) Gallons per Minute (GPM) To: Pounds per Square Inch (psi) Pounds per Square Inch (psi) Pounds per Square Inch (psi) Pounds per Square Inch (psi) Bar Kilo Pascals (kPa) Mega Pascals (MPa) Kilograms per cm2 (kg/cm2) Use this formula: bar x 14.504 kPa x 0.145 MPa x 145 kg/cm2 x 14.223 psi ÷ 14.504 psi ÷ 0.145 psi ÷ 145 psi ÷ 14.223 To: Specific Gravity (SG) Specific Gravity (SG) Specific Gravity (SG) Kilograms per meter3 (kg/m3) Pounds per foot3 (lb/ft3) Degrees API Use this formula: kg/m3 x 0.001 = SG lb/ft3 ÷ 62.4 = SG 141.5 ÷ (API +131.5)= SG SG x 1000 = kg/m3 SG x 62.4 = lb/ft3 (141.5 ÷ SG) - 131.5 = API To: Inches (in.) Feet (ft.) millimeters (mm) meters (m) Use this formula: mm ÷ 25.4 m x 3.281 in. x 25.4 ft. ÷ 3.281 = in. = ft. = mm =m To: Degrees Centigrade (°C) Degrees Fahrenheit (°F) Use this formula: (°F - 32) ÷ 1.8 (1.8 x °C) + 32 = °C = °F To: Gallons per Minute (GPM) Gallons per Minute (GPM) Gallons per Minute (GPM) Gallons per Minute (GPM) Feet per Second (FPS) Kilograms per Hour (kg/H) Meters per Second (m/s) Cubic meters per Hour (m3/hr) Use this formula: FPS x 448.83 x A1 (kg/H ÷ kg/m3) x 4.403 m/s x A2 x 15,852 m3/hr ÷ 0.2271 GPM ÷ (448.83 x A1) GPM x kg/m3 ÷ 4.403 GPM ÷ (A2 x 15,852) GPM ÷ 4.4 = GPM = GPM = GPM = GPM = FPS = kg/H = m/s = m3/hr = psi = psi = psi = psi = bar = kPa = MPa = kg/cm2 Variables: A1= Area of pipe in square feet (ft2) A2= Area of pipe in square meters (m2) kg/m3 = Specific gravity in kilograms/cubic meter 58/60 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc. Level Switches Weights The approximate shipping weights shown below are for standard models. Weights will vary based on pipe size, length and flange size. Consult the factory for the weight of a specific unit. Floats Displacers Model pounds kilograms Page Model pounds kilograms Page 101* 102* 103* 55 80 130 25 37 60 12 12 12 701 702 703 18 18 30 8.5 8.5 13.5 36 36 36 108 109* 121* 130 125 40 59 53 18 21 12 12 704 705 706 30 20 30 13.5 9 9 36 36 36 122* 123* 124* 50 80 90 23 36 42 12 12 12 707 708 730 32 32 20 14.5 14.5 9 36 36 39 201* 202* 203* 45 26 26 20.5 12 12 17 17 17 731 732 733 20 32 32 9 14.5 14.5 39 39 39 204* 205* 206* 26 45 45 12 20.5 20.5 17 17 17 734 735 736 22 22 34 10 10 15.5 39 39 39 207* 208 209* 45 89 62 20.5 22 29 17 17 17 737 740* 741* 34 28 48 15.5 12.5 22 39 33 29 221* 301 303 22 12 12 10 5.5 5.5 17 23 23 742* 743* 750 60 68 24 27 31 11 29 29 43 304 401 402 12 15 12 5.5 7 5.5 23 26 26 751 752 753 24 36 36 11 16 16 43 43 43 403 404 405 28 15 12 12.5 7 19 26 26 26 754 755 756 26 26 38 12 12 17 43 43 43 406 70 32 26 757 802 804 38 185 50 17 82 22.5 43 29 33 *Add weights from the table below to the base model weight for VV, VVT, or VH configurations with flanges. VV, VVT and VH Additional Weights Size 150# 300# 600# pounds kilograms pounds kilograms pounds kilograms 1” 5 2.5 8 4 9 4.5 1-1/2” 8 4 15 7 15 7 2” 12 5.5 16 7.5 18 8.5 Weights shown in this table include two flanges, pipe nipples, and fittings. Note: Consult the factory for additional weight due to accessories or non-standard requirements. Form 912 (01.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 59/60 SOR Inc. | Lenexa, KS USA | 913-888-2630 | Fax 913-888-0767 | SORInc.com REGIONAL OFFICES China Middle East SOR China | Beijing, China SOR Measurement & Control Equipment Trading JLT | Dubai, UAE +86 (10) 5820 8767 | Fax +86 (10) 58 20 8770 60/60 Registered Quality System to ISO 9001 +971 4 3699042 | Fax +971 4 3698989 | 913-888-2630 | SORInc.com Form 912 (01.15) ©SOR Inc.