43.155/1 RXE 110: Monitoring unit for fume cupboards Used in conjunction with RLE 152 air-volume controllers for monitoring the air volume or the air speed as a function of the sash opening in fume cupboards; with optical and acoustic alarm (as per EN 14175). Housing of thermoplastic; suitable for fitting onto walls; frontal membrane keypad with 5 function keys for max, min, mute, low speed and present. Two power cables: 2,9 m in length; 2 × 0,5 mm2 and either 11 × 0,14 mm2 (F001) or 9 × 0,14 mm2 (F002). Type RXE 110 F001 RXE 110 F002 F001: Inputs (Ri = 100 kΩ) Actual-value signal Setpoint signal, night Air-volume limitation Setpoint signal Outputs Contacts: present 1) Contacts: alarm 1) Setpoint signal 2) Ext. contacts 100% Power supply 24 V~ Power consumption Back-up in the event of mains power failure Ambient temp. Ambient humidity Degree of protection Description Power Weight kg For sash sensor SGU 100 For flow sensor SVU 100 24 V~ 24 V~ 0,45 0,45 0...10 V 0...10 V 0...10 V = 0...100% 0...10 V 34 V = (1...10 mA) 34 V = (1...10 mA) 0...10 V, load > 5 kΩ 10 V +15, –20%, 50...60 Hz approx. 7 VA >15 min. (super cap) 0...40 °C < 90 %rh IP 44 (EN 60529) 1) Protected against reversed polarity 2) Protected against short circuits and excess voltage up to 24 V~ F002: Inputs (Ri = 100 kΩ) Actual-value signal Setpoint signal: night Air-volume limitation 0...10 V 0...10 V 0...10 V = 0...100% Y06367 Outputs Contacts: present 1) Contacts: alarm 1) Setpoint signal 2) Wiring diagram Dimension drawing Fitting instructions 34 V = (1...10 mA) 34 V = (1...10 mA) 0...10 V, load > 5 kΩ F001 F002 F001 F002 A06640 A08041 M06641 MV 505458 MV 505608 Operation: F001 Together with the RLE 152 air-volume controller, the fume-cupboard monitoring unit monitors the volume of air through the fume cupboard. The sash's opening is fed as the setpoint to the monitoring unit and compared with the air volume's actual value. The deviation is indicated both optically and acoustically, as required by EN 14175. An illuminated strip of 12 LEDs indicates the deviation between the target and the actual values. Starting at 10% , an LED lights up for each further 10% (but the first LED denotes ‘In operation’). If the setpoint and the actual value are within ± 8% of each other, the LEDs light up green. If the actual value is too small by more than 8% , they light up red, and if it is too large by more than 8% , the LEDs light up yellow. In the event of a malfunction, an acoustic signal is emitted and the alarm contacts open. The acoustic alarm sounds if the air volume's actual value is either smaller by more than 8% or larger by more than 8% than the setpoint. The acoustic alarm is activated with a time delay of about 15 seconds. The alarm can be suppressed by pressing the mute key. When actual value and setpoint again reach equilibrium, the acoustic alarm is again ready for operation. The alarm signal fed to the BMS is not affected by the mute key. On fume cupboards with both vertical and horizontal sashes, the signal from the horizontal sash can be fed to the monitoring unit – via external contacts – with priority over the vertical sash. The setpoint signal (10 V = 100% ) from the monitoring unit (GY/PK wire) is fed back to the monitoring unit (PK wire) via the external switch (on the fume cupboard’s sash). A key combination allows the setpoint signal of the SGU 100 sash sensor to be restricted (minimum restriction) to between 10 and 100% . If the limit is undercut, the comparison between setpoint and actual value uses the programmed value. If this value is undercut, an acoustic signal is emitted. If the SGU 100 sash sensor is fitted at the rear of the fume cupboard, the setpoint signal can be inverted by employing an internal change-over switch (jumper). Sauter Components 7143155003 04 43.155/2 RXE 110 Operation: F002 Together with the RLE 152 air-volume controller, the fume-cupboard monitoring unit monitors the air intake speed in the fume cupboard. The air speed is fed as the setpoint to the monitoring unit and compared with the actual value. The deviation is indicated both optically and acoustically, as required by EN 14175. An illuminated strip of 12 LEDs indicates the deviation between the target and the actual values (but the first LED denotes ‘In operation’). Starting at 0,1 m/s, an LED lights up for each further 0,1 m/s. If the setpoint is equal to or greater than the actual value, the LEDs light up green and there is no acoustic signal. If the limit of the actual value is undercut, the LEDs light up red and an acoustic signal is emitted with a time lag of about 15 seconds, and the alarm contacts open. The alarm can be suppressed by pressing the mute key. When actual value and setpoint again reach equilibrium, the acoustic alarm is again ready for operation. The alarm signal fed to the BMS is not affected by the mute key. The setpoint for controlling the air intake speed can be set – using a key combination – between 0,1 and 1,0 m/s. The difference to the setpoint for the alarm can also be set via a key combination between 0,1 and 1,0 m/s. The monitoring unit has a PI control loop with an integral action time of 1 s. The amplification factor can be set between 0,05 and 1,5 using a key combination. Function keys max min low speed mute present Regardless of the position of the sash, an air volume of 100% is given, the acoustic alarm is activated and the alarm contacts open. Regardless of the position of the sash, an air volume of 20% is given, the acoustic alarm is activated and the alarm contacts open. Reduces the inlet speed by 30% (factor of 0.7) at the sash in daytime operation. Suppresses the acoustic alarm. Revokes the night-time mode; suppresses BMS control via timer. On pressing the present key, the red ‘night’ LED goes out and the contacts are opened. Additional technical data Complies with:EMC directive 89/336/EC EN 61000-6-1/ EN 61000-6-2 EN 61000-6-3/ EN 61000-6-4 Dimension drawing 67 125 max min low speed mute present 31 2900 M06641 Sauter Components 7143155003 04 RXE 110 43.155/3 Wiring diagram RXE 110 F001 S2 (Vmin) 0 – ΔV = +/-8% S1 min a max 24 V~ BU 0 1 100% 20% BN 1 + normal (factor =1.0) low speed (fact=0.7) mode A/B: mute 0 10 V= RD VT GN + – xi 0...10V w BU alarm – present 0...10V + Xs night a= 0...10V SGU 100 V=100 % YE RD/BU WH GY 0...10V BK Xs Limit V b= PK RLE 152 GY/PK b timer on present RLE 152 A/B A06640e RXE 110 F002 S2 (gain) normal (factor =1.0) low speed (fact=0.7) (Xs) 0 PI 1 100% 20% BN a S1 max BU min 24 V~ (Δv [m/s]) mute 0 timer on present w + – alarm – GN 0...10V + VT Limit V b= Xs night a= 0...10V 0...10V SVU 100 YE RD/BU WH GY RLE 152 BK Xi present RD b BU A08041c Key BN brown xi actual-value signal, RLE 152 (F001) BU blue xi actual-value signal, SGU 100 (F002) RD red Xs setpoint signal, SGU 100 (F001) PK pink Xs night setpoint signal, night YE yellow w command signal, RLE 152 GY/PK grey/pink Limit limitation signal RD/BU red/blue S1 presence indicator BK WH black S2 white alarm indicator opto-coupler GY grey optional VT violet GN green Sauter Components 7143155003 04 43.155/4 RXE 110 Example of application 1. Volume of return air controlled in proportion to the amount that the sash is opened. 3 geschlossener Raum enclosed room local étanche M 1 PD/F 2 PI RLE 152 F001 8 8 RXE 101 10 2 2 3 M 3 M RLE 150 F100 4 PI PD/F 5 PD/F PI 1 6 PI G RLE 152 F001 EY Limit V PD/F SGU 100 F001 RLE 152 F001 9 7 T P RXE 110 F001 B06333d 1 2 3 VAV controller Damper drive Reducing box 4 5 6 Pressure controller Return-air VAV controller for fume cupboards Sash sensor Sauter Components 7 8 9 10 EY Monitoring unit Manual damper Room-temperature controller VAV adding unit Control centre; night mode; collective alarm 7143155003 04 RXE 110 43.155/5 Example of application 2. Constant air intake speed controlled independently of the amount that the sash is opened. 3 geschlossener Raum enclosed room local étanche M 1 PD/F 2 PI RLE 152 F001 8 8 RXE 101 10 2 5 3 M 1 PD/F PI 2 3 M PD/F PI SVU 100 F004 6 RLE 152 F001 PD/F EY Limit V RLE 152 F001 9 T 7 P RXE 110 F002 B08162c 1 2 3 VAV controller Damper drive Reducing box 4 5 6 Pressure controller Return-air VAV controller for fume cupboards Flow sensor Sauter Components 7 8 9 10 EY Monitoring unit Manual damper Room-temperature controller VAV adding unit Control centre; night mode; collective alarm Printed in Switzerland Right of amendment reserved N.B.: A comma between cardinal numbers denotes a decimal point © Fr. Sauter AG, CH-4016 Basle 7143155003 04