WIRING WIRING DIAGRAM DIAGRAM Packaged Two Stage Heat/Two Stage Electric Air Conditioner 4. If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature rating of at least 105°C. 5. For supply wire ampacities and overcurrent protection, see unit rating plate. BROWN S YELLOW RED VARIABLE SPEED BLOWER MOTOR 5 4 3 2 1 5 4 3 2 1 GREEN BLACK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 F NEUTRALS W1 7 12 11 10 4 8 9 (STATUS) RED 10 5 NONE RED WHITE DUAL CAPACITOR 240V 208V RED 24V TRANSFORMER COM ECONOMIZER PLUG RED RED BROWN BROWN 5 C R C W2 (HIGH HEAT AUTO DEMAND) HEAT STAGE GREEN BLUE H GREEN HI/LO DEHUMIDIFY IGNITION / BLOWER CONTROL BOARD 1 BLUE 1 Y G P2 S Y2 HUM C C ECONOMIZER PLUG ORANGE BLUE YELLOW BLACK GRAY GREEN LINE HIGH PRESSURE R SWITCH DEHUM YELLOW BLUE R OUTDOOR FAN MOTOR ADJUST BLACK GRAY WHITE BROWN BLACK RED GREEN BLACK YE/BK (CFM) YEL CONT XMFR NORM (+) (-) TEST BK/WH COOL ABCD BROWN YELLOW 9 8 7 6 5 YELLOW 4 3 2 1 YELLOW ORANGE HEAT ABCD BROWN GAS VALVE 624652 9 8 7 6 5 4 3 2 1 YELLOW ORANGE YELLOW RED PARK1 COOL EAC T1 3 RED PARK2 BLUE 5 VIOLET HI-HEAT 6 LO-HEAT YELLOW T2 2 5A FUSE L1 0 L2 PRIMARY GAS VALVE HI LO C 1 2 3 LOW PRESSURE SWITCH CCH COMPRESSOR GREEN LPS BLACK PRIMARY GAS VALVE LO HI C RED RED HPS GAS VALVE 624787 9 8 7 6 5 4 3 2 1 YELLOW FLAME ROLL-OUT 9 8 7 6 5 4 3 2 1 BLACK FLAME SENSOR BLACK ECONOMIZER JUMPER HARNESS ASSY. 8-WIRE RED IF EQUIPPED BLUE HIGH TEMP LIMIT WHITE 60Hz 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. 3. Ne convient pas aux installations de plus de 150 V a la terre. P6 16-PIN TO 208/230 VAC POWER SUPPLY 208/230 Volt Single Phase BLUE NOTES: 1. Disconnect power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150V to ground. BLACK BLUE 1 INDUCER 2 MOTOR 3 1 2 3 RED BLACK YELLOW GREEN WHITE BROWN BLACK RED WHITE TO DISCHARGE AIR SENSOR YELLOW BLUE BLACK YELLOW IGNITOR Note: See Installation Instructions for specific blower speed setting. WHITE SYSTEM STATUS - 2nd STAGE HEAT DEMAND No demand for 2nd stage heat 2nd stage heat demand (Normal operation) 2nd stage heat demand, high pressure switch not closed LED STATUS (GREEN) OFF ON Flashing SYSTEM STATUS - HI/LO DEHUMIDIFY (Cooling Mode only) LED STATUS (GREEN) Factory jumper wire “R” to “DEHUM” in place or “Close on Fall” humidistat (Low humidity) - Closed ON Humidistat open (High Humidity) Low Speed Blower call OFF BROWN BROWN L Y2 R C Y1 G CONTROL WIRING LEADS W1 W2 Refer to Installation Instructions for Connection to Indoor Thermostat SYSTEM STATUS - IGNITION Power On (Normal Operation) High Limit Circuit Open Pressure Switch Open with Inducer On Pressure Switch Closed with Inducer Off Failed Ignition (5 attemps) - Control in 1 Hour Lockout 208-230 Volt Polarity Issue Excess High limit trips (5) within one call for heat Excess pressure switch cycles (5) within one call for heat Excess flame dropouts (5) within one call for heat Not Used Flame present with gas valve Off LED STATUS (RED) ON 1 Flash 2 Flashes 3 Flashes 4 Flashes 5 Flashes 6 Flashes 7 Flashes 8 Flashes 9 Flashes 10 Flashes SYSTEM STATUS - CFM NOT USED LED STATUS (YELLOW) OFF GREEN BLACK GRAY LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE 7111820 (Replaces 7111270) 11/11