PK-93458-10-00-0A
Dual & Multi-Control Rocker Switches
Cat. Nos. 1754 and 1755
15A-120V AC (15A Each Load, 20A Max. Total)
Incandescent Only
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
WARNINGS AND CAUTIONS:
•To be installed and/or used in accordance with appropriate electrical codes and regulations. •Each individual rocker switch on this control is rated at 15A 120V AC. The total load on
this control must not exceed 20A 120V AC.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing device.
• For safety, make sure switch box and loads are properly grounded.
• Use this device only with copper wire. With aluminum wire use only devices marked
•Side wire terminals accept up to #14-12 AWG wire. Quickwire™ terminals accept
CO/ALR or CU/AL.
#14 AWG solid copper wires ONLY!
Step 1
WARNING: To avoid fire, shock, or death; turn off power at circuit
breaker or fuse and test that power is off before wiring!
Step 3 cont'd
To Quickwire™:
Step 2 Preparing wires:
This switch can be wired by using side wire terminal screws or through Quickwire™ openings.
NOTE: Common terminal must be side wired.
• Remove insulation from each wire in the wall box to appropriate length based on installation
method.
• To side wire remove insulation approximately 3/4" (1.9 cm).
• For Quickwire™ installation remove insulation per strip gauge on device approximately 5/8" (1.6 cm).
Strip Gauge (measure bare wire using strip gauge on back of device)
NOTE: Quickwire™ terminals accept #14 AWG solid copper wires ONLY!
• Insert straight #14 AWG solid copper wires into round Quickwire™ holes.
For circuits with #12 AWG solid copper or copper clad wires, use side wiring terminals
instead. If the switch must be replaced or rewired after Quick-wiring, gently press the tip
of a small screwdriver in the release slot and back the wire out gradually. If the switch or
Quickwire™ terminal become damaged, do not reuse.
Figure 1
To Load
Step 3 Installing your Switch –
NOTE: Ensure that the word "TOP" on strap is facing up when wiring switch.
WARNING: Only #12 AWG wire should be used for the Common (Line) connection of this device.
• Leviton recommends installing a 2-gang wall box (refer to Figure 1).
• Use a single-gang wall box adapter plate (not included) to cover the 2-gang box
(refer to Figure 1).
• Run wall box wires through adapter (refer to Figure 1).
• Connect wires per appropriate WIRING DIAGRAM as follows:
To Side Wire:
NOTE: Side wire terminals accept #14-12 AWG wire.
• Loop wires clockwise 3/4 turn around terminal screws.
• Tighten terminal screws to 14-16 in.-lbs. of torque.
2 Gang Box
To Line
Single-Gang Adapter Plate
(not included)
Step 4 Switch Mounting (refer to Figure 2):
Cat. No. 1754 2-Rocker Switch Wiring Diagram
NOTE: Dress wires with a bend in order to relieve stress when mounting device.
•Installation may now be completed by carefully positioning all wires to provide room in wall box
for switch.
•Mount switch into box with mounting screws supplied. Attach wallplate (not included).
1754
Green
Ground
Common
Figure 2
Black
Hot (Black)
To Load
Switch
(1754 depicted)
Ground
Screw
Load 1
Black
Line
120V AC, 60 Hz
Load 2
White
White
Neutral (White)
2 Gang Box
Cat. No. 1755 3-Rocker Switch Wiring Diagram
To Line
1755
Green
Ground
Common
Step 5 Restore Power: Restore power at circuit breaker or fuse.
Installation is complete.
Hot (Black)
Black
Black
Line
120V AC, 60 Hz
Load 2
Load 3
White
Neutral (White)
PK-93458-10-00-0A
Load 1
Black
White
White
FOLD SCHEME
8.5¨
LEVITON INSTRUCTION SHEET/MANUAL
SPECIFICATIONS
Front Panel
PK-93458-10-00-0A
Cat. No.
5.5¨
Black
Helvetica
40 Lb. offset
Paper size:
Overall size: 8.5" X 5.5"
Final fold size: 1.7" X 2.75"
Front Panel
1
2
3
4
Cat. No.
DOCUMENTATION
7835007
HSZ
07.16.07
1.7¨
2.75¨
Fold Line
Front Panel
Panel Line
Cat. No.
#'s =
Fold Sequence
Download