Related Document

advertisement
LuxMaster® Series 53
Area Lighting
70-150W HPS, 175W MH
P R O D U C T
O V E R V I E W
Features:
Durable die-cast aluminum housing for long-life performance
Optical assembly designed for maximum performance
Removable ballast tray electrical system for installation and maintenance ease
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency
Optics available in flat tempered glass, sag glass, drop acrylic and drop
polycarbonate
Available in a variety of IES light distributions patterns and cutoff
classifications
Standard product is designed to mount to pipe mast arm. Direct pole mount
arms are available
Applications:
Arm ordered separate, see page 144
Parking lots
Roadways
Residential communities
Commercial environments
Office communities
All electrical components warranted by American Electric Lighting's 6-year
guarantee
UL Listed
Mogul base, E39, socket standard
Suitable for -30°C MH / -40°C HPS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
DIMENSIONS
PREFERRED SELECTION CATALOG NUMBERS
53 10S CA MT1 R2 DA
53 15S CA MT1 R2 FG
53 10S RH 120 R3 FG
Effective Projected Area (EPA)
The EPA for the LuxMaster® Series 53 with
refractor 1.4 sq. ft.
Approx Wt = 30 lbs.
136
Product Guide
Effective Projected Area (EPA)
The EPA for the LuxMaster® Series 53 with flat
lens is 1.1 sq. ft.
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Series 53
Area Lighting
70-150W HPS, 175W MH
O R D E R I N G
I N F O R M AT I O N
Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C
53 LuxMaster
Shoebox
S HPS
M MH
07 70W
10 100W
13 100/150W
wired 100
14 100/150W
wired 150
15 150W
17 175W
Voltage
Ballast
Wattage / Source
Series
Refer to the ballast matrix on
page 151 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
MR Mag Reg (3 coil)
CT CWI
120
208
240
277
347
480
MT1
MT2
MT7
TT3
DT2
DT4
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to optical matrix
277V
below for compatibility
347V
480V
Multi-tap Wired 120V
Multi-tap Wired 240V
Multi-tap Wired 277V
Tri-tap Wired 347V
Dual Tap 120/240 Wired 240V
Dual Tap 240/480 Wired 480V
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
FG Flat Glass Clear
Tempered6
SG Sag Glass Refractor
Options
Mounting
(blank) Internal fitter (1-1/4”)
M2 Internal fitter (pre-set 2”)
Paint1
(blank)
BK
GY
WH
Bronze (standard)
Black
Gray
White
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe
Starter4
(blank)
EC
OP
PS
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
Protected/Auto Shutoff5
Listing
(blank)
CS
UL Listed (standard)
CSA Certified
Misc.
PC
SS
LA
5H
NL
SH
HK
Notes:
1
2
3
4
5
6
Other colors available, please contact your
local American Electric Lighting representative
Voids UL/CSA Certified Options and not
available in MT, TT, and DT voltages
PC, & SH not available with NR option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
Nighttime FriendlyTM optic
Photocontrol Included per
Voltage Specified3
Stainless Steel Fasteners (external)
Lightning Arrestor (Void UL/CSA
Listed Options)
50 Hertz Ballast Cycle5
NEMA Label on Housing
Shorting Cap3
Hinge Keeper
Optic Distribution
05S
07S
10S
15S
17M
R2 DA
N
N
N
N
-
R3 DA
N
N
N
N
-
R2 DP
N
N
N
N
-
R3 DP
N
N
N
N
-
R2 FG
N
N
N
N
N
R3 FG
N
N
N
N
N
R2 SG
N
N
N
N
N
R3 SG
N
N
N
N
N
Product Guide