Power cables ACSR Aluminium conductor steel reinforced Application Temperature range Bare conductor for overhead power transmission. Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . .80˚C – in a short circuit (duration up to 5 s) . . . . . . . . . 200˚C Standards SFS 5701 IEC 61089 EN 50182 AS Draka Keila Cables www.draka.ee Construction A conductor consisting aluminium and galvanized steel wires, built up in concentric layers. The centre wires are steel and outer layer aluminium wires. Member of Prysmian Group www.prysmian.com Paldiski Road 31 76606 Keila, Estonia Phone +372 674 7466 Fax +372 674 7468 The technical specifications may change any time without prior notice. ACSR Aluminium conductor steel reinforced Basic data Product name according to IEC EAN code Construction data Aluminium No of wires Diameter of wire Cross section Weight (5) Steel No of wires Diameter of wire Cross section Weight (5) Complete conductor No of wires Diameter of conductor Cross section Weight (5) Delivery data Standard delivery length Standard delivery drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Max. DC resistance of conductor (20˚C) (3) (5) Current ratings In air Short circuit currents (2) Max. permissible short circuit current for 1 sec. (4) ACSR 34/6 SPARROW 34-A1/S1A-6/1 01 202 02-2 ACSR 42/25 SAVO 42-A1/S1A-12/7 01 202 28-2 ACSR 54/9 RAVEN 54-A1/S1A-6/1 01 202 05-3 ACSR 85/14 PIGEON 85-A1/S1A-6/1 01 202 09-1 ACSR 89/52 DOTTEREL 89-A1/S1A-12/7 01 202 31-2 6 2,68 33,8 92,9 1 2,68 5,64 43,9 7 8,04 39,5 137 12 2,12 42,4 117 7 2,12 24,7 193 19 10,6 67,1 310 6 3,37 53,5 147 1 3,37 8,92 69,4 7 10,1 62,4 216 6 4,25 85,1 234,0 1 4,25 14,2 110,0 7 12,8 99,3 344,0 6 3,08 89,4 247,0 7 3,08 52,2 408,0 19 15,4 142 654,0 kg 2500 K11 390 2500 K12 860 2200 K11 560 2000 K12 770 2500 K16 1790 kN N/mm2 N/mm2 1/K 12,2 64000 78000 19,2 x 10–6 13,52 93000 102000 15,6 x 10–6 17,11 64000 78000 19,2 x 10–6 24,13 64000 78000 19,2 x 10–6 33,37 93000 102000 15,6 x 10–6 Ω/km 0,848 0,682 0,536 0,337 0,323 A 210 250 280 360 400 kA 3,7 5,4 5,8 9,2 11,4 64 100+ ACSR 152/25 OSTRICH 152-A1/S1A-26/7 01 202 15-2 ACSR 242/39 HAWK 242-A1/S1A-26/7 01 202 18-3 ACSR 305/39 DUCK 305-A1/S1A-54/7 01 202 21-3 ACSR 402/52 CONDOR 402-AL1/52-ST1A 01 054 07-2 ACSR 565/72 FINCH 565-A1/S1A-54/19 01 202 24-4 26 2,73 152 420 7 2,12 24,7 193 33 17,3 177 613 26 3,44 242 668 7 2,68 39,5 309 33 21,8 281 976 54 2,68 305 842 7 2,68 39,5 309 61 24,1 344 1151 54 3,08 402,3 1110,5 7 3,08 52,2 410 61 27,7 454,5 1520,5 54 3,65 565 1562 19 2,19 71,6 561 73 32,9 637 2123 kg 2500 K18 1760 2500 K20 2780 2200 K22 3290 2300 K22 3908 1400 K22 3380 kN N/mm2 N/mm2 1/K 54,8 61000 76000 19,2 x 10–6 84,9 61000 76000 19,2 x 10–6 96,8 50000 67000 19,3 x 10–6 123,75 51000 68000 19,3 x 10–6 174 46000 63000 19,3 x 10–6 Ω/km 0,190 0,120 0,0949 0,0719 0,0512 A 550 745 845 1000 1250 kA 16,5 26,1 32,5 43,7 60,1 64 100+ mm mm2 kg/km mm mm2 kg/km mm mm2 kg/km m Basic data Product name according to IEC EAN code Construction data Aluminium No of wires Diameter of wire Cross section Weight (5) Steel No of wires Diameter of wire Cross section Weight (5) Complete conductor No of wires Diameter of conductor Cross section Weight (5) Delivery data Standard delivery length Standard delivery drum Total weight (1) Mechanical data (2) Minimum tensile strength of the conductor Initial modulus of elasticity of conductor Final modulus of elasticity of conductor Coefficient of linear expansion of conductor Electrical data (2) Maximum DC resistance of conductor (20˚C) (3) (5) Current ratings In air Short circuit currents (2) Maximum permissible short circuit current for 1 sec. (4) mm mm2 kg/km mm mm2 kg/km mm mm2 kg/km m 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Calculated with steel core. 4) Initial temperature of conductor before short circuit 40˚C, final temperature of conductor after short circuit 200˚C. 5) Nominal value according to standard. AS Draka Keila Cables www.draka.ee Member of Prysmian Group www.prysmian.com Paldiski Road 31 76606 Keila, Estonia Phone +372 674 7466 Fax +372 674 7468 The technical specifications may change any time without prior notice.