Low Voltage Alternators - 4 pole LSA 49.3 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Electrical and mechanical data Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Specially adapted to applications The LSA 49.3 alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. Compliant with international standards The LSA 49.3 alternator conforms to the main international standards and regulations: - IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA C22.2 n°100-14, UL 1446 (UL 1004 on request), marine regulations, etc. It can be integrated into a CE marked generator. The LSA 49.3 is designed, manufactured and marketed in an ISO 9001 and ISO 14001 environment. Top of the range electrical performance ● Class H insulation. ● Standard 6-wire re-connectable winding, 2/3 pitch, type no. 6S (12-wire on request). ● Voltage range 50 Hz: 380V - 400V - 415V and 220V - 230V - 240V. ● Voltage range 60 Hz: 380V - 416V - 440V - 480V and 220V - 240V. ● High efficiency and motor starting capacity. ● Other voltages are possible with optional adapted windings: - 50 Hz : 440 V (n° 7), 500 V (n° 9), 600 V (n° 22 or 23), 690 V (n° 10 or 52). - 60 Hz : 380 V and 416 V (n° 8), 600 V (n° 9). ● R 791 interference suppression conforming to standard EN 61000-6-3, EN 61000-6-2, EN 55011 group 1 class B standard for European zone (CE marking). Excitation and regulation system suited to the application Excitation system Regulation options C.T. Volage regulator AREP PMG (option) Current transformer for paralleling R450 M R450 R450 R450 T Option D510 C Option Mains paralleling 3-phase sensing Remote voltage potentiometer √ - - √ Option √ Included Included √ Option √ Included Included √ √ : possible mounting Protection system suited to the environment ● The LSA 49.3 is IP 23. ● Standard winding protection for clean environments with relative humidity ≤ 95 %, including indoor marine environments. Options : - Filters on air inlet : derating 5%. - Filters on air inlet and air outlet (IP 44) : derating 10%. - Winding protections for harsh environments and relative humidity greater than 95%. - Space heaters. - Thermal protection for winding and shields. Reinforced mechanical structure using finite element modelling ● Compact and rigid assembly to better withstand generator vibrations. ● Steel frame. ● Cast iron flanges and shields. ● Twin-bearing and single-bearing versions designed to be suitable for engines on the market. ● Half-key balancing. ● Sealed for life ball bearings, regreasable bearings (optional). ● Standard direction of rotation: clockwise when looking at the drive end view (for anti-clockwise, derate the machine by 5%). Accessible terminal box proportioned for optional equipment ● Easy access to the voltage regulator and to the connections. ● Possible inclusion of accessories for paralleling, protection and measurement. ● Connection bar for reconnecting voltage. 2 Electric Power Generation Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz General characteristics Insulation class Winding pitch Number of wires Protection Altitude Overspeed Air flow H 2/3 (winding 6S) 6 (12 option) IP 23 ≤ 1000 m 2250 min-1 3 1 m /s (50Hz) / 1.2 m3/s (60Hz) Excitation system AVR type Voltage regulation (*) Short-circuit current Totale Harmonic distortion THD (**) Waveform: NEMA = TIF (**) Waveform: IEC = FHT (**) AREP R 450 ± 0.5 % 300% (3 IN) : 10s at no load < 4 % - on load < 4 % < 50 <2% (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting) Ratings 50 Hz - 1500 R.P.M. kVA / kW - P.F. = 0.8 Duty/T°C Class/T°K Phase Y Continuous duty/40°C H/125°K 3 ph. ∆ YY 49.3 S4 49.3 M6 49.3 M8 49.3 L9 49.3 L10 380V 400V 415V 220V 230V 240V - 660 528 730 584 820 656 910 728 1000 800 - 440V Continuous duty/40°C F/105°K 3 ph. 380V 400V 415V 220V 230V 240V - 595 476 660 528 760 608 820 656 900 720 - 220V kVA kW kVA kW kVA kW kVA kW kVA kW 620 496 665 532 810 648 820 656 950 760 440V Stand-by/40°C H/150°K 3 ph. 380V 400V 415V 220V 230V 240V - 725 580 780 624 910 728 1000 800 1085 868 - 220V Stand-by/27°C H/163°K 3 ph. 440V 380V 400V 415V 220V 230V 240V - 745 596 810 648 945 756 1020 816 1130 904 - 220V 560 448 600 480 710 568 740 592 840 672 685 548 730 584 885 708 920 736 1030 824 440V 220V 715 572 765 612 925 740 965 772 1080 864 Ratings 60 Hz - 1800 R.P.M. kVA / kW - P.F. = 0.8 Duty/T°C Class/T°K Continuous duty/40°C H/125°K 3 ph. Phase Y ∆ YY 49.3 S4 49.3 M6 49.3 M8 49.3 L9 49.3 L10 Continuous duty/40°C F/105°K kVA kW kVA kW kVA kW kVA kW kVA kW 380V 416V 220V 240V 653 522 725 580 815 652 905 724 990 792 440V Stand-by/40°C H/150°K 3 ph. 480V 208V 220V 240V 715 572 795 636 890 712 990 792 1083 866 756 605 840 672 940 752 1045 836 1146 917 825 660 915 732 1025 820 1140 912 1250 1000 380V 416V 220V 240V 588 470 655 524 735 588 815 652 891 713 440V Stand-by/27°C H/163°K 3 ph. 480V 208V 220V 240V 644 515 715 572 805 644 895 716 975 780 681 545 760 608 850 680 940 752 1031 825 743 594 825 660 925 740 1025 820 1125 900 380V 416V 220V 240V 693 554 770 616 865 692 960 768 1049 839 Electric Power Generation 440V 3 ph. 480V 208V 220V 240V 758 606 845 676 945 756 1050 840 1148 918 802 642 890 712 1000 800 1110 888 1215 972 875 700 970 776 1090 872 1210 968 1325 1060 380V 416V 220V 240V 718 574 800 640 895 716 1000 800 1089 871 440V 480V 208V 220V 240V 787 630 875 700 980 784 1090 872 1192 954 832 666 925 740 1040 832 1155 924 1260 1008 908 726 1005 804 1130 904 1255 1004 1375 1100 3 Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Efficiencies 400V - 50 Hz (..... P.F.: 1) (— P.F.: 0.8) LSA 49.3 S4 % LSA 49.3 L9 % 97,0 97,0 95,8 96,0 96,7 96,6 96,0 95,9 96,1 96,1 96,0 95,0 94,7 93,7 94,0 93,0 92,0 95,0 94,6 94,1 93,9 250 350 450 550 650 750 850 93,0 200 kVA 300 400 96,1 95,6 94,0 96,0 94,3 94,1 92,3 250 kVA 350 450 550 650 750 95,6 94,7 900 1000 96,7 96,6 1100 850 93,0 95,6 95,2 95,0 94,1 94,0 93,0 150 800 96,0 95,0 94,7 93,1 50 700 96,8 96,5 95,0 94,5 600 LSA 49.3 L10 97,0 96,0 92,0 500 % 96,1 95,0 93,3 100 LSA 49.3 M6 % 97,0 95,2 93,9 94,0 kVA 150 95,4 95,2 92,9 50 96,6 kVA 100 200 300 400 500 600 700 800 900 1000 1100 LSA 49.3 M8 % 97,0 96,4 96,2 96,3 96,2 96,0 95,0 95,2 94,3 95,1 94,6 94,0 94,3 93,6 93,0 kVA 50 150 250 350 450 550 650 750 850 950 Reactances (%). Time constants (ms) - Class H / 400 V Kcc Xd Xq T’do X’d T’d X”d T”d X”q Xo X2 Ta Short-circuit ratio Direct-axis synchro. reactance unsaturated Quadrature-axis synchro. reactance unsaturated No-load transient time constant Direct-axis transient reactance saturated Short-circuit transient time constant Direct-axis subtransient reactance saturated Subtransient time constant Quadrature-axis subtransient reactance saturated Zero sequence reactance unsaturated Negative sequence reactance saturated Armature time constant Other class H / 400 V data io (A) ic (A) uc (V) ms kVA % W W 4 No-load excitation current On-load excitation current On-load excitation voltage Response time (∆U = 20% transient) Start (∆U = 20% cont. or 30% trans.) Transient ∆U (on-load 4/4) - P.F.: 0.8 LAG No-load losses Heat dissipation S4 0.36 350 210 2002 17.5 100 14.0 10 16.3 0.35 15.2 15 M6 0.42 294 176 2074 14.2 100 11.3 10 12.8 0.48 12.1 15 M8 0.34 348 209 2094 16.6 100 13.3 10 14.9 0.61 14.1 15 L9 0.47 303 182 2138 14.1 100 11.3 10 12.4 0.78 11.9 15 L10 0.38 348 209 2153 16.1 100 12.9 10 14.1 0.33 13.5 15 1.1 4.2 57 500 1350 13 8233 32519 1 4.1 55 500 1452 11 10288 34995 1 3.8 51 500 1708 12 9226 37082 1 3.7 49 500 2211 11 11189 36425 1 3.8 51 500 2211 12 10343 39772 Electric Power Generation Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Transient voltage variation 400V - 50 Hz AREP or PMG system Load application 20% S4 Voltage drop 15% M6 M8 L9 L10 10% 5% 0% 0 100 200 300 400 500 600 700 800 900 1000 kVA at 0.8 P.F. Load rejection S4 20% M6 M8 Voltage rise 15% L9 L10 10% 5% 0% 0 100 200 300 400 500 600 700 800 900 1000 kVA at 0.8 P.F. Motor starting S4 30% M6 L9 L10 M8 Voltage drop 25% 20% 15% 10% 5% 0% 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 Locked rotor kVA at 0.6 P.F. 1) For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8 2) For voltages other than 400V (Y), 230V (D) at 50 Hz, then kVA must be multiplied by (400/U)2 or (230/U)2. Electric Power Generation 5 Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Efficiencies 480V - 60 Hz (..... P.F.: 1) (— P.F.: 0.8) LSA 49.3 S4 % 97,0 95,9 95,9 95,3 96,0 95,8 94,5 94,3 94,2 92,5 93,0 92,0 200 94,0 kVA 300 400 500 600 700 800 900 1000 LSA 49.3 M6 92,0 92,4 200 300 kVA 400 500 600 700 95,9 95,8 96,0 95,9 94,0 94,5 94,1 94,3 93,0 94,0 91,9 100 200 91,3 kVA 300 400 500 600 700 800 900 1000 1100 93,0 1000 1100 1200 96,6 96,6 95,5 95,3 95,3 95,1 93,8 93,3 200 300 400 kVA 500 600 700 800 900 1000 1100 1200 1300 LSA 49.3 M8 % 97,0 96,2 96,2 96,1 95,7 96,0 95,0 95,0 94,8 94,0 94,7 93,2 94,5 93,0 92,6 92,0 100 200 300 kVA 400 500 600 700 800 900 1000 1100 1200 Reactances (%). Time constants (ms) - Class H / 480 V Kcc Xd Xq T’do X’d T’d X”d T”d X”q Xo X2 Ta Short-circuit ratio Direct-axis synchro. reactance unsaturated Quadrature-axis synchro. reactance unsaturated No-load transient time constant Direct-axis transient reactance saturated Short-circuit transient time constant Direct-axis subtransient reactance saturated Subtransient time constant Quadrature-axis subtransient reactance saturated Zero sequence reactance unsaturated Negative sequence reactance saturated Armature time constant Other class H / 480 V data io (A) ic (A) uc (V) ms kVA % W W 6 No-load excitation current On-load excitation current On-load excitation voltage Response time (∆U = 20% transient) Start (∆U = 20% cont. or 30% trans.) Transient ∆U (on-load 4/4) - P.F.: 0.8 LAG No-load losses Heat dissipation 1300 96,1 95,0 94,2 900 96,6 96,0 95,0 800 LSA 49.3 L10 97,0 97,0 92,0 95,1 92,9 % % 95,0 95,2 93,0 91,9 100 95,3 94,9 94,0 96,5 95,7 95,0 94,0 91,0 96,5 96,4 96,0 95,0 91,0 LSA 49.3 L9 % 97,0 S4 0.35 365 219 2002 18.2 100 14.5 10 17.0 0.67 15.8 15 M6 0.40 307 184 2074 14.8 100 11.8 10 13.4 0.46 12.6 15 M8 0.32 362 217 2094 17.3 100 13.8 10 15.5 0.78 14.7 15 L9 0.45 317 190 2138 14.8 100 11.8 10 13.0 0.87 12.4 15 L10 0.36 363 217 2153 16.8 100 13.4 10 14.7 0.96 14.1 15 1.1 4.3 67 500 1616 13 12720 40028 1 4.2 65 500 1747 11 15710 43671 1 3.8 60 500 2071 12 14270 45867 1 3.8 58 500 2646 11 16873 45528 1 3.9 59 500 2646 12 15726 49172 Electric Power Generation 1400 Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Transient voltage variation 480V - 60 Hz AREP or PMG system Load application 20% S4 M6 Voltage drop 15% M8 L9 L10 10% 5% 0% 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 kVA at 0.8 P.F. Load rejection S4 20% M6 M8 Voltage rise 15% L9 L10 10% 5% 0% 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 kVA at 0.8 P.F. Motor starting S4 30% M6 M8 L9 L10 Voltage drop 25% 20% 15% 10% 5% 0% 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 Locked rotor kVA at 0.6 P.F. 1) For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8 2) For voltages other than 480V (Y), 277V (D), 240V (YY) at 60 Hz, then kVA must be multiplied by (480/U)2 or (277/U)2 or (240/U)2. Electric Power Generation 7 Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 49.3 S4 Symmetrical Current (A) Asymmetrical Time (ms) LSA 49.3 M6 Symmetrical Current (A) Asymmetrical Time (ms) LSA 49.3 M8 Symmetrical Current (A) Asymmetrical Time (ms) Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x 1.732 - Parallel star : current value x 2 8 Electric Power Generation Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) LSA 49.3 L9 Symmetrical Current (A) Asymmetrical Time (ms) LSA 49.3 L10 Symmetrical Current (A) Asymmetrical Time (ms) Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) 1 0.87 1.3 Continuous 1 1.5 2.2 5 sec. 2 sec. Maximum duration (AREP/PMG) 10 sec. Electric Power Generation 9 Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Single bearing dimensions L Xg AH 105 LB 620 55.5 228.5 10 Access to regulator Cable output 259 C Dimensions (mm) and weight Type L without PMG LSA 49.3 S4 LSA 49.3 M6 LSA 49.3 M8 LSA 49.3 L9 LSA 49.3 L10 90 608 1008 Ø 235 S DIA. Qty 12 as shown on Ø M 0 400 - 1 - 0.050 PMG optional AIR OUTLET 6 Flange (mm) S.A.E. 620 ß° Cable output Ø BX - 0.100 Y DIA, Qty X Eq. Sp. on Ø U. 336.5 12 ØP 0 Ø N - 0.127 6 Access to terminals 110 10 AIR INLET Access to rotating diodes 35 686 786 LB C Xg Weight (kg) Coupling Flex plate 14 1267 1241 560 328.5 1427 Flange S.A.E 1 X 1357 1331 650 629 1574 Flange S.A.E 1/2 X 1357 1331 650 636 1635 Flange S.A.E 0 X 1446 1421 650 673 1788 Flange S.A.E 00 1446 1421 650 681 1837 Flex plate (mm) S.A.E. BX 18 X X P N M W ß° U X Y AH 1 773 511.175 530.225 7 15° 14 466.7 438.15 8 14 25.4 1/2 773 584.2 619.125 6 15° 18 571.5 542.92 6 17 15.7 0 773 647.7 679.45 7 11° 15’ 00 773 787.4 850.9 6 11°15’ Torsional analysis data Ø 140 Ø 115 Ø 90 Lr Ø 145 Ø 149 Ø 145 Ø 145 Ø 135 Ø 130 Xr Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2) Flange S.A.E. 14 Flange S.A.E. 18 Xr Lr M J Xr Lr M Type LSA 49.3 S4 LSA 49.3 M6 LSA 49.3 M8 LSA 49.3 L9 LSA 49.3 L10 579 1255 535 620 1345 628 1345 666 1435 676 1435 J 8.39 567 1255 535 8.65 596 9.49 604 1345 598 9.75 622 10.04 612 1345 624 10.30 678 11 654 1435 680 11.27 695 11.36 662 1435 697 11.62 NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the LeroySomer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. 10 Electric Power Generation Low Voltage Alternators - 4 pole LSA 49.3 - 660 to 1000 kVA - 50 Hz / 825 to 1250 kVA - 60 Hz Two bearing dimensions L Xg 165 105 LB 620 55.5 240.5 Access to terminals 620 11°15’ Cable output Access to regulator 10 AIR OUTLET 6 C 50 500 Dimensions (mm) and weight Type AIR INLET 2 x 2 holes Ø 35 608 1008 0 400 - 1 27 100 Access to rotating diodes L without PMG 16 M12 DIA. Qty 12 as shown on Ø 679.45 336.5 50 LSA 49.3 S4 LSA 49.3 M6 LSA 49.3 M8 LSA 49.3 L9 LSA 49.3 L10 106 27 Ø 235 - 0.013 PMG optional Ø 100 - 0.035 0 Ø 647 - 0.127 Ø 773 Cable output 686 786 LB Xg Weight (kg) 1378 1213 596 1483 1468 1303 636 1616 1468 1303 643 1677 1558 1393 682 1829 1558 1393 688 1878 Torsional analysis data Ø 115 Ø 90 Ø 140 Ø 145 Lr Ø 149 Ø 145 Ø 145 Ø 135 Ø 125 Ø 110 Ø 100 Xr Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2) Type LSA 49.3 S4 LSA 49.3 M6 LSA 49.3 M8 LSA 49.3 L9 LSA 49.3 L10 Xr 538 578 585 621 629 Lr 1409 1499 1499 1589 1589 M 506 568 594 650 667 J 7.96 9.07 9.62 10.58 10.94 NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the LeroySomer site, 3D drawing files are available upon request. The torsional analysis of the transmission is imperative. All values are available upon request. Electric Power Generation 11 www.emersonindustrial.com www.leroy-somer.com © Emerson 2014. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Emerson have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Headquarters: Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Share Capital: 65 800 512 €, RCS Angoulême 338 567 258. 5279 en - 2015.07 / b