Universal Ballasts Basic-12 ® Basic Electronic Ballasts for T12 Lamp Applications - Technology for Magnetic Ballast Replacements - Exceeds Federal Ballast Efficiency Requirements The Basic-12™ ballast family is designed for replacement of magnetic T12 ballasts during fixture maintenance or in combination with relamping programs to reduce energy consumption. Basic-12™ ballasts provide electronic energy saving performance, generating energy savings of greater than 20% when replacing a magnetic ballasts while still using the same T12 lamps. Basic-12™ ballasts fully comply with today’s new federal ballast efficiency requirements for installation into new fixtures as well as with the 2010 requirements for replacement ballasts. DOE compliant ballasts are available for use with both standard and energy saving lamps (Note: The B260I120M-A can only be used with energy saving F96T12 lamps.) The Basic-12™ product line covers the high volume requirements for T12 lighting: Features • Energy Efficient - Greater than 20% Increase in Efficiency - Lowers Lighting Operation Costs • Full Light Output - Provides Same Light Levels as Magnetic Ballasts Being Replaced • Quiet Operation - Significantly Quieter than Magnetic Ballasts • High Frequency Operation - No Lamp Flickering • Light Weight - Low Profile Case - Simplifies Transportation & Installation - Less Interference with Ballast Channel Cover During Replacement • Slimline Ballasts Feature Parallel Lamp Operation - When One Lamp Fails, Other Lamp Remains Lit • Same Warranty as Energy Saving Magnetic T12 Ballasts - Three-year Ballast Warranty 1-Lamp F34 & F40T12, 120V 2-Lamp F34 & F40T12, 120V 1 or 2 - Lamp F34 & F40T12, 277V 2-Lamp F96T12 & F96T12/ES, 120-277V 2-Lamp F96T12HO/ES, 120-277V Replacement Comparison F34/40T12 Rapid Start 1.7 lb Weight Reduction Basic-12™ ballast is significantly smaller and weighs less than the ballast it is replacing. Basic-12™ ballast are ideal for replacing magnetic ballasts in almost every application. Universal Lighting Technologies, Inc. • 26 Century Blvd., Suite 500 • Nashville, TN 37214-3686 • (615) 316-5100 • www.universalballast.com © 2007 Universal Lighting Technologies Basic-12 ® Performance Savings 2xF34T12 Comparison Ballast 2xF96T12/ES Comparison Lamp Input Power Magnetic 2xF34T12 F34T12 74 B234SR120M-A F34T12 59 Savings: Ballast Lamp Input Power Magnetic 2xF96T12/ES F96T12/ES 133 B260IUNVHP F96T12/ES 110 15 watts Operating Savings Savings: 23 watts Operating Savings Utility Rate ( $/KWH) 0.08 Utility Rate ( $/KWH) 0.08 Annual Operating Hours 3500 Annual Operating Hours 3500 Annual Savings: $4.20 Replacement with Basic-12 rather than a standard magnetic saves $4.20 per year in operating costs. With higher utility rates and longer operating hours, savings will be even more. • Rapid Start Basic-12 ballasts wire exactly the same way as their magnetic counterparts • Mounting dimensions are the same as the magnetic ballasts • Low profile case makes it easier to replace the ballast channel without pinching wires. Part Number B134R120M-A 000I B234SR120M-A 000I B234SR277M-A 000I B260I120M-A 000I * 0 B260IUNVHP 000I B295SRUNVHP 000I Annual Savings: $6.44 Replacement with Basic-12 rather than a standard magnetic saves $6.44 per year in operating costs. With higher utility rates and longer operating hours, savings will be even more. • Instant Start Basic-12 ballasts are wired slightly differently than magnetic ballasts but easy to follow instructions are included. • Parallel lamp operation keeps remaining lamp lit when one lamp fails. Lamp Application (1) F34T12 or F40T12, 120V (2) F34T12 or F40T12, 120V (1) or (2) F34T12 or F40T12, 277V (2) F96T12/ES, 120V (2) F96T12 (Std & ES), 120-277V (2) F96T12HO, 120-277V Product Code 76838624257 76838624214 76838624367 76838624222 76838624224 76838624231 Basic-12 models are covered by a 36 month warranty. Visit www.universalballast.com for additional warranty information. For use with energy savings lamps only (F96T12/WM,SS,EW) B260I120M-A is shorter than standard magnetic ballast. A self-tapping screw may be required for mounting. B12J0407 B234SR120M-A APPLICATION and PERFORMANCE SPECIFICATION Description: High frequency electronic ballast for (2) F40T12ES, (2) F40T12, (2) F32T12, or (2) F40T10 lamps (and equivalent U-bend lamps) • Line Voltage: 120vac , ±10%, 60Hz • Series Lamp Operation Lamps Type F40T12ES F40T12 F32T12 F40T10 • Rapid Start • Passive Power Factor Correction Input Nominal Power Ballast Ballast Efficacy Harmonic Crest # Watts Line Amps Factor Factor Factor Total Factor 2 2 2 2 59 71 56 75 0.49 0.63 0.48 0.65 > .90 > .90 > .98 > .95 0.86 0.90 0.90 0.91 1.46 1.27 1.61 1.21 < 30% < 30% < 25% < 30% < 1.7 < 1.7 < 1.7 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: • Meets ANSI Standard C82.11-1993 • Meets ANSI Standard C62.41-1991 • Meets FCC Part 18 (Class B) for EMI and RFI Consumer Limits • Meets CSA Standard 654 for Ballast Efficiency • Meets Energy Star® Requirements Safety: • No PCB's • UL listed (Class P, Type 1 Outdoor, Type HL) • CSA Certified Application: • Minimum Starting Temperature: 50° F, 10° C Energy Saving Lamps: 60° F, 16° C • Maximum Case Temperature: 167° F, 75° C • Sound Rated: A • Remote Mounting: 20 ft. max. lead length, 18 AWG Physical Parameters Length: 9.50" Width: 1.70" Height: 1.18" Weight: 1.70 lbs. Lead Length: White, Black Red, Blue Yellow 22" (± 1") 26" (± 1") 45" (± 1") Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 3 years from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in China or North America Blue Blue Red Red Black Line BALLAST White Yellow Yellow LAMP LAMP Ballast must be grounded in accordance with national and local electrical codes. 1-800-BALLAST www.universalballast.com November 2006 Specification Sheet Catalog Number: S70MLTLC3M Document #: 010-9651-07 Date: 06/28/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 120 208 240 277 70W HIGH PRESSURE SODIUM 70W HPS S62 120/208/240/277 5% 60 HZ 5/3/3/2 HX-HPF 180° C 7MF 300 VOLTS 90° C 005-1410-MF HPS 150-3A Al/Al Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 12310-153 Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Open Line Current in Amps Power Input Circuit Factor Oprtng Open Start Watts Volts High 0.85 1.50 0.90 98 120 High 0.52 0.88 0.50 98 120 High 0.45 0.75 0.44 98 120 High 0.38 0.65 0.35 98 120 Drop Out Volts 90 155 180 208 Min. Start Temp. -40°C -40°C -40°C -40°C UL Temp. Code B B B B Reference Drawing Line Volt 120 208 240 277 Power Factor High High High High Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 0.77 0.91 0.75 2.20 0.55 1.15 115 130 0.44 0.56 0.44 1.30 0.30 0.65 115 130 0.37 0.46 0.38 1.20 0.25 0.60 115 130 0.33 0.43 0.33 1.00 0.20 0.55 115 130 Physical Characteristics Mounting Holes (In.) Overall Dimensions, Inches Length 3.94 Height 2.81 Stack 1.38 Over Coils 2.74 Diam 0.25 Length 3.50 Width 2.44 Bracket CapacitorDim. Mntng Dim Length Width Section Length 1.25 2.19 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST Short Circuit Current (A) Min. Max. 1.55 2.80 1.55 2.80 1.55 2.80 1.55 2.80 www.universalballast.com Ballast Net Weight 4.13 Lead Length Inches 12-14 S100MLTLC3M 100W High Pressure Sodium 60Hz HX-HPF Specification Sheet 120 Input Volts Regulation Line Volts 208 240 277 ±5% ±5% ±5% ±5% ±5% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 122 W 122 W 122 W 122 W 122 W 120 V 120 V 120 V 120 V 120 V Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating 1.12 S54 0.65 0.60 0.52 0 Open Circuit 2.20 1.30 1.10 0.95 0 Starting 0.80 0.55 0.41 0.35 0 Recommended Fuse (Amps) 7 5 3 3 0 Lamp Dropout Voltage (Line) 96 V 166 V 192 V 222 V V 277V (BLACK) LAMP 240V (VIOLET) 208V (ORANGE) CAP (YEL) STARTER 120V (BLK/YEL) 2 COM (YEL) UL Temperature Ratings Insulation Class Temperature Code MIN. Starting Temperature (RED/BLK) 3 1 3 CAP (RED) COM (YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) B B B B -40°F -40°C -40°F -40°C -40°F -40°C -40°F -40°C A 0.234 Dia Thru 4 Holes B MAX -40°F -40°C CAPACITOR Specifications Microfarads Volts (min.) 10 uf 10 uf 10 uf 10 uf 10 uf 280 V 280 V 280 V 280 V 280 V 60Hz Test Procedures High Potential Test 1 Minute 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 110 - 130 110 - 130 110 - 130 110 - 130 110 - 130 Secondary Current Shorted (A) 2.60 - 3.20 2.60 - 3.20 2.60 - 3.20 2.60 - 3.20 2.60 - 3.20 Input Operating Current (A) 1.02 - 1.24 0.59 - 0.72 0.55 - 0.67 0.47 - 0.58 - Input Open Circuit Current (A) 1.10 - 3.15 0.65 - 1.86 0.55 - 1.57 0.48 - 1.36 - Input Short Circuit Current (A) 0.66 - 1.00 0.36 - 0.55 0.32 - 0.50 0.26 - 0.42 - Temp Rating: 90 °C Max Case Temp 105 °C 2.00 in 2.00 in 2.00 in 2.00 in 2.00 in Height: 2.70 in BTL: 10 ft Dimension B 3.36 in 3.36 in 3.36 in 3.36 in 3.36 in Width / Diameter: 2.16 in Weight 6.00 lbs 6.00 lbs 6.00 lbs 6.00 lbs 6.00 lbs 12-14 12-14 12-14 12-14 12-14 Cu / Cu Cu / Cu Cu / Cu Cu / Cu Cu / Cu Core and Coil Specifications Dimension A 2.812" 0.250 Dia Thru 2 Holes 2.438" 3.500" 3.938" Reference Drawing Capacitor: 005-1413-MF Ignitor: HPS150-3A No. 1 (Red or Blue) Lead Lengths (inches) Coil Material (Pri. / Sec.): No. 2 (Brown) No. 3 (Yellow) Document #: 010-9648-07 Date: 2/6/2007 Status: Production Replaces Catalog #: 12310-90 1.250" 2.000" For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 2/2/2007 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com S150MLTLC3M 150W High Pressure Sodium 60Hz HX-HPF Specification Sheet 120 Input Volts Regulation Line Volts 208 240 277 ±5% ±5% ±5% ±5% ±5% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 188 W 188 W 188 W 188 W 188 W 120 V 120 V 120 V 120 V 120 V Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating 1.70 S55 0.95 0.85 0.70 277V (BLACK) LAMP 240V (VIOLET) 208V (ORANGE) CAP (YEL) STARTER 120V (BLK/YEL) 2 Open Circuit 3.10 1.65 1.55 1.30 Starting 1.95 1.10 1.00 0.80 Recommended Fuse (Amps) 10 5 5 5 0 Lamp Dropout Voltage (Line) 96 V 165 V 192 V 220 V V COM (YEL) UL Temperature Ratings Insulation Class Temperature Code MIN. Starting Temperature (RED/BLK) 3 1 3 CAP (RED) COM (YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) B A B A -40°F -40°C -40°F -40°C -40°F -40°C -40°F -40°C A 0.234 Dia Thru 4 Holes B MAX -40°F -40°C CAPACITOR Specifications Microfarads Volts (min.) 14 uf 14 uf 14 uf 14 uf 14 uf 280 V 280 V 280 V 280 V 280 V 60Hz Test Procedures High Potential Test 1 Minute 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 110 - 135 110 - 135 110 - 135 110 - 135 110 - 135 Secondary Current Shorted (A) 3.90 - 4.75 3.90 - 4.75 3.90 - 4.75 3.90 - 4.75 3.90 - 4.75 Input Operating Current (A) 1.50 - 1.90 0.80 - 1.00 0.75 - 0.95 0.60 - 0.80 - Input Open Circuit Current (A) 1.55 - 4.40 0.85 - 2.40 0.80 - 2.20 0.65 - 1.85 - Input Short Circuit Current (A) 1.20 - 1.85 0.65 - 1.00 0.60 - 0.95 0.50 - 0.80 - Temp Rating: 90 °C Max Case Temp 105 °C 2.50 in 2.50 in 2.50 in 2.50 in 2.50 in Height: 2.69 in BTL: 10 ft Dimension B 3.85 in 3.85 in 3.85 in 3.85 in 3.85 in Width / Diameter: 2.69 in Weight 7.00 lbs 7.00 lbs 7.00 lbs 7.00 lbs 7.00 lbs 12-14 12-14 12-14 12-14 12-14 Cu / Al Cu / Al Cu / Al Cu / Al Cu / Al Core and Coil Specifications Dimension A 2.812" 0.250 Dia Thru 2 Holes 2.438" 3.500" 3.938" Reference Drawing Capacitor: 005-1415-MF Ignitor: HPS150-3A No. 1 (Red or Blue) Lead Lengths (inches) Coil Material (Pri. / Sec.): No. 2 (Brown) No. 3 (Yellow) Document #: 010-11816-01 Date: 2/6/2007 Status: Production Replaces Catalog #: 12310-165 1.250" 2.000" For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 2/2/2007 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com S250MLTAC4M 250W High Pressure Sodium 60Hz CWA Specification Sheet 120 208 240 277 ±10% ±10% ±10% ±10% ±10% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 295 W 295 W 295 W 295 W 295 W 190 V 190 V 190 V 190 V 190 V 2.50 1.45 1.25 1.10 Input Volts Regulation Line Volts Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating S50 277V (BLACK) LAMP 240V (VIOLET) (RED/BLK) 3 1 3 208V (ORANGE) STARTER 120V (BLK/YEL) CAP (RED) Open Circuit 1.30 0.70 0.65 0.55 Starting 2.00 1.20 1.00 0.85 Recommended Fuse (Amps) 7 4 4 3 0 Lamp Dropout Voltage (Line) 90 V 160 V 180 V 210 V V COM (YEL) UL Temperature Ratings Insulation Class Temperature Code MIN. Starting Temperature CAP (RED) 2 COM (YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) B B B B -40°F -40°C -40°F -40°C -40°F -40°C -40°F -40°C A 0.250 Dia Thru 4 Holes B MAX -40°F -40°C CAPACITOR Specifications Microfarads Volts (min.) 35 uf 35 uf 35 uf 35 uf 35 uf 240 V 240 V 240 V 240 V 240 V 60Hz Test Procedures High Potential Test 1 Minute 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 170 - 210 170 - 210 170 - 210 170 - 210 170 - 210 Secondary Current Shorted (A) 3.75 - 4.60 3.75 - 4.60 3.75 - 4.60 3.75 - 4.60 3.75 - 4.60 Input Operating Current (A) 2.25 - 2.75 1.30 - 1.60 1.10 - 1.40 1.00 - 1.20 - Input Open Circuit Current (A) 0.65 - 1.90 0.35 - 1.00 0.35 - 0.90 0.30 - 0.80 - Input Short Circuit Current (A) 1.55 - 2.30 0.90 - 1.35 0.80 - 1.15 0.65 - 1.00 - Rated Temp 90 °C Max Case Temp 105 °C 1.80 in 1.80 in 1.80 in 1.80 in 1.80 in Height: 3.13 in BTL: 10 ft Dimension B 3.55 in 3.55 in 3.55 in 3.55 in 3.55 in Width / Diameter: 2.91 in Weight 10.0 lbs 10.0 lbs 10.0 lbs 10.0 lbs 10.0 lbs 12-14 12-14 12-14 12-14 12-14 Cu / Al Cu / Al Cu / Al Cu / Al Cu / Al Core and Coil Specifications Dimension A 4.250" 0.250 Dia Thru 2 Holes 3.875" 4.375" 4.750" Reference Drawing Capacitor: 005-1421-MF Ignitor: HPS400-3A No. 1 (Red or Blue) Lead Lengths (inches) Coil Material (Pri. / Sec.): No. 2 (Brown) No. 3 (Yellow) Document #: 010-11949-00 Date: 12/9/2006 Status: Production Replaces Catalog #: New Design 1.250" 2.000" For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 11/10/2006 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com Specification Sheet Catalog Number: Document #: Date: Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Part Number Lamp Starter FEATURES: Line Volt 480 Line Volt 480 S25048TAC4M 010-9759-00 5/27/03 250W HPS S50 480 (120 Aux) 10% 60 HZ 2 CWA 180 C 35 MF 280 005-4075-P HPS400-3A Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 0.62 0.38 0.36 285 200 Power Factor High Height 4.25 Drop Out Volts 260 Min. Start Temp. -40C UL Temp. Code A Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 0.56 0.69 0.19 0.54 0.25 0.45 185 215 Stack 1.85 Over Coils 3.65 Reference Drawing Short Circuit Current (A) Min. Max. 3.30 4.40 Physical Characteristics Mounting Holes (In.) Bracket CapacitorDim. Mntng Dim Diam Length Width Length Width Dia. Length 0.25 4.38 3.88 1.80 4.60 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST 1232-321S Yes Yes UL & CSA 5 FT Utilizes Precise-Wound Coils Overall Dimensions, Inches Length 4.75 250W HIGH PRESSURE SODIUM www.universalballast.com Ballast Net Weight 10.40 Lead Length Inches 12-14 Specification Sheet Catalog Number: S400MLTAC5M Document #: 010-9770- 02 Date: 04/16/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 120 208 240 277 400W HIGH PRESSURE SODIUM 400W HPS S51 LAMP 120/208/240/277 10% 60 HZ 15/8/8/5 CWA 180° C 48MF 280 VOLTS 90° C 005-1422-MF HPS 400-3A Cu/Cu Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1230-93S Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 4.00 2.30 2.80 470 200 High 2.30 1.40 1.70 470 200 High 2.00 1.20 1.45 470 200 High 1.80 1.10 1.30 470 200 Drop Out Volts 85 145 170 195 Min. Start Temp. -40°C -40°C -40°C -40°C UL Temp. Code D D D D Reference Drawing Line Volt 120 208 240 277 Power Factor High High High High Test Limits Line Current, Amps Operating Open Min. Max. Min. Max. 3.64 4.44 1.15 3.29 2.09 2.55 0.70 2.00 1.82 2.22 0.60 1.72 1.64 2.00 0.55 1.57 Physical Characteristics Mounting Holes (In.) Overall Dimensions, Inches Length 5.75 Height 4.25 Stack 2.25 Open Circuit Short Voltage (V) Min. Max. Min. Max. 2.40 3.60 180 240 1.40 2.10 180 240 1.20 1.82 180 240 1.00 1.60 180 240 Over Coils 4.13 Diam 0.25 Length 5.38 Width 3.88 Bracket CapacitorDim. Mntng Dim Length Width Section Length 1.81 3.88 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST Short Circuit Current (A) Min. Max. 5.35 8.00 5.35 8.00 5.35 8.00 5.35 8.00 www.universalballast.com Ballast Net Weight 15.50 Lead Length Inches 12-14 Specification Sheet Catalog Number: Document #: Date: Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Part Number FEATURES: Line Volt 480 S40048TAC5M 010-9767-00 2/28/2003 400W HPS S51 480 10% 60 HZ 5 CWA 180 C 48 MF 280 VOLTS 005-4081-P 400W HIGH PRESSURE SODIUM Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1232-331S Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 1.05 0.60 0.60 467 200 Drop Min. UL Out Start Temp. Volts Temp. Code 330 -40°C D Reference Drawing Line Volt 480 Power Factor High Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 0.91 1.11 0.30 0.86 0.30 0.78 190 210 Overall Dimensions, Inches Length Height 5.75 4.25 Stack 2.25 Over Coils 4.25 Short Circuit Current (A) Min. Max. 5.75 7.40 Physical Characteristics Mounting Holes (In.) Bracket CapacitorDim. Ballast Lead Mntng Dim Net Length Diam Length Width Length Width Dia. Length Weight Inches 0.25 5.38 3.88 1.80 4.60 15.50 12-14 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST www.universalballast.com Specification Sheet Catalog Number: Document #: Date: Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Winding Material (Pri/Sec) Lamp Starter FEATURES: Line Volt 120 208 240 277 S1000MLTAC5M 010-9752- 02 06/23/2004 1000 W HIGH PRESSURE SODIUM 1000W HPS S52 120/208/240/277 10% 60 HZ 20/15/10/10 CWA 180° C 26MF 525 VOLTS 90° C 005-2776-MF Cu/Cu HPS 1000-4B Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1230-97S Yes Yes UL & CSA 15 FT Utilizes Precise-Wound Coils Power Factor High High High High Electrical Characteristics Line Current in Amps Open Input Circuit Oprtng Open Start Watts Volts 9.50 6.10 5.00 1100 440 5.50 3.50 3.00 1100 440 4.80 3.10 2.60 1100 440 4.20 2.70 2.20 1100 440 Drop Out Volts 90 155 180 208 Min. Start Temp. -40°C -40°C -40°C -40°C UL Temp. Code C C C C Reference Drawing Line Volt 120 208 240 277 Power Factor High High High High Operating Min. Max. 8.65 10.55 5.01 6.11 4.37 5.33 3.82 4.66 Physical Characteristics Mounting Holes (In.) Overall Dimensions, Inches Length 5.75 Height 4.25 Stack 3.75 Test Limits Line Current, Amps Open Short Min. Max. Min. Max. 3.05 8.72 5.30 8.00 1.75 5.01 3.10 4.70 1.55 4.43 2.65 4.00 1.35 3.86 2.30 3.50 Over Coils 5.63 Diam 0.25 Length 5.38 Width 3.88 Bracket Mntng Dim Length Width - Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST Open Circuit Voltage (V) Min. Max. 400 485 400 485 400 485 400 485 www.universalballast.com Short Circuit Current (A) Min. Max. 6.40 8.00 6.40 8.00 6.40 8.00 6.40 8.00 CapacitorDim. Section 1.81 Length 4.25 Ballast Net Weight 26.00 Lead Length Inches 12-14 Specification Sheet Catalog Number: Document #: Date: Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Part Number Starter FEATURES: Line Volt 480 Line Volt 480 S100048TAC5M 010-9762-02 2/6/04 1000W HPS S52 480 (120V Aux.) 10% 60 HZ 8 CWA 180 C 26 MF 525 VOLTS 005-2776-MF HPS1000-4B Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 2.45 1.50 1.80 1100 440 Power Factor High Height 4.25 Test Limits Line Current, Amps Operating Open Min. Max. Min. Max. 2.18 2.66 0.75 2.15 Stack 3.75 Over Coils 6.00 Drop Out Volts 360 Min. Start Temp. -40°C UL Temp. Code D Open Circuit Short Voltage (V) Min. Max. Min. Max. 1.26 2.16 425 465 Reference Drawing Short Circuit Current (A) Min. Max. 6.00 7.65 Physical Characteristics Mounting Holes (In.) Bracket CapacitorDim. Mntng Dim Diam Length Width Length Width Section Length 0.25 5.38 3.88 1.91 4.25 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Ligthing Technologies Representative. 1-800-BALLAST 1232-571S Yes Yes UL & CSA 15 FT Utilizes Precise-Wound Coils Overall Dimensions, Inches Length 5.75 1000W HIGH PRESSURE SODIUM www.universalballast.com Ballast Net Weight 25.00 Lead Length Inches 12-14 Specification Sheet Catalog Number: S40048TAC4M Document #: 010-9654-03 Date: 04/30/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 480 400W HIGH PRESSURE SODIUM 400W HPS S51 480 10% 60 HZ 5 CWA 180° C 55 MF 240 VOLTS 90° C 005-1594-MF HPS400-3A Cu/Cu Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1232-331U Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 1.00 0.42 0.80 465 190 Drop Min. UL Out Start Temp. Volts Temp. Code 340 -40°C D Reference Drawing Line Volt 480 Power Factor High Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 0.91 1.11 0.21 0.60 0.50 0.90 170 210 Overall Dimensions, Inches Length Height 4.75 4.25 Stack 2.44 Over Coils 4.12 Short Circuit Current (A) Min. Max. 6.00 7.45 Physical Characteristics Mounting Holes (In.) Bracket CapacitorDim. Ballast Lead Mntng Dim Net Length Diam Length Width Length Width Dia. Length Weight Inches 0.25 4.38 3.88 1.81 3.50 14.50 12-14 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST www.universalballast.com Specification Sheet Catalog Number: S400MLTAC4M Document #: 010-9653- 02 Date: 04/20/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 120 208 240 277 400W HIGH PRESSURE SODIUM 400W HPS S51 120/208/240/277 10% 60 HZ 15/8/8/5 CWA 180° C 55MF 240 VOLTS 90° C 005-1594-MF HPS 400-3A Cu/Cu Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1230-93U Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 3.80 1.85 3.10 440 190 High 2.20 1.10 1.80 440 190 High 1.80 0.90 1.60 440 190 High 1.60 0.80 1.35 440 190 Drop Out Volts 85 145 170 195 Min. Start Temp. -40C -40C -40C -40C UL Temp. Code D D D D Reference Drawing Line Volt 120 208 240 277 Power Factor High High High High Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 3.46 4.22 0.93 2.65 2.20 3.40 170 210 2.00 2.44 0.55 1.57 1.30 2.00 170 210 1.64 2.00 0.45 1.29 1.14 1.72 170 210 1.46 1.78 0.40 1.14 0.95 1.50 170 210 Physical Characteristics Mounting Holes (In.) Overall Dimensions, Inches Length 4.75 Height 4.25 Stack 2.32 Over Coils 4.19 Diam 0.25 Length 4.38 Width 3.88 Bracket CapacitorDim. Mntng Dim Length Width Section Length 1.81 3.50 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST Short Circuit Current (A) Min. Max. 6.00 7.60 6.00 7.60 6.00 7.60 6.00 7.60 www.univeralballast.com Ballast Net Weight 14.50 Lead Length Inches 12-14 MH 70 HID CORE & COIL BALLASTS • 60 Hz • Minimum starting temperature: -30° C • Normal and High Power Factor models available WATT Nom Max Open Circuit Watts Input Circuit Fuse Wir Input Catalog* Volts Number Type Input Current Voltage Rating Dia (1) 70 WATT M98 METAL HALIDE LAMP - Medium Base 120 or 1.70 4 1.04 3 208 or M70MLTLC3M HX-HPF 95 245 4 240 or 0.87 3 277 0.78 2 120 or 1.70 4 M70TRILC3M HX-HPF 95 0.78 245 2 4A 277 or 347 0.60 2 480-120 M7048TLC3M HX-HPF 95 0.50 245 1 6 (1) 70 WATT M85 METAL HALIDE LAMP - Double Ended 120 or 1.70 4 208 or 1.04 3 HX-HPF 95 245 4 M70MLTLC3D 240 or 0.87 3 277 0.78 2 DESCRIPTION METAL HALIDE Dimensions Ref Dwg Capacitor A Min Mfd Volt B Dry Film Dia Ht Ignitor Total Weight (lbs.) Oil Filled Oval Ht Max UL Catalog Distance Bench Number to lamp (ft) Top Rise PC1 1.3 2.9 8 280 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 A B B B PC1 1.3 2.9 8 280 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 A PC1 1.3 2.9 8 300 1.2 2.7 1.31x2.16 2.2 4.3 MH100-3A 10 E 10 A B B B PC1 1.4 2.8 8 300 1.2 2.7 1.31x2.16 2.2 4.3 MH70-3B SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 REFERENCE DRAWING PC1 0.199 Dia Thru 4 Holes A B MAX 500K 2.812˝ 0.250 Dia Thru 2 Holes 502K 518 2.438˝ 3.500˝ 3.938˝ 700 718 Wiring Diagram 4A Wiring Diagram 4 277V L W 5.25” 1.25” M 4.60” S 0.25” Cap (Yellow) 208V 120V BRef. Dwg. PC1 Lamp Eyelet 3 277V (Blue) 1 3 120V Cap Cap 347V 240V (Black) M L STARTER 2 Com (Yellow) (Blue) 1 3 STARTER To Lamp Shell (Yellow) Wiring Diagram 6 120V (AUX) INC LAMP W MAX (White) (Black) or (Yellow) Line Cap See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Lamp Eyelet 3 2 To Lamp Shell Com Cap S (Black) Bracket (Yellow) W Cap HID CORE & COIL WIRING DIAGRAMS Lamp Eyelet (Blue) 3 1 3 STARTER 2 PERMISSIBLE To Lamp Shell Com (White) or (Yellow) PAGE 5-18 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDE Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 100 WATT M90 OR M92 METAL HALIDE LAMP - Medium Base 5 R-NPF 1.45 1 1 1.5 277 118 277 1133-14R 1.05 3 R-HPF 3 120 or 2.30 5 208 or 1.30 4 M100MLTLC3M HX-HPF 130 250 4 PC1 1.7 240 or 1.10 3 277 0.95 3 480-120 M10048TLC3M HX-HPF 140 0.62 250 2 6 PC1 1.7 120 or 2.30 5 277 or M100TRILC3M HX-HPF 130 0.95 250 3 4A PC1 1.7 347 0.80 3 (1) 100 WATT M91 METAL HALIDE LAMP - Double Ended 120 or 2.30 5 1.30 4 208 or 250 17 PC1 2.0 M100MLTLC3D HX-HPF 130 240 or 1.10 3 277 0.95 3 3 MH 100 • 60 Hz • Minimum starting temperature: -30° C • Normal and High Power Factor models available WATT Capacitor Min Mfd Volt B Ignitor Dry Film Dia Ht Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise 2.5 — 10 — 280 — 1.56 — 2.69 — 1.31x2.16 — 2.2 2.4 MH100-3A 5 E 3.2 10 280 1.2 2.7 1.31x2.16 2.2 6.3 MH100-3A 10 A 3.2 10 280 1.2 2.7 1.31x2.16 2.2 5.0 MH100-3A 10 C 3.2 10 280 1.2 2.7 1.31x2.16 2.2 6.3 MH100-3A 10 A 3.5 10 280 1.2 2.7 1.31x2.16 2.7 6.3 MH70-3B 5 A Capacitors are available as an option for high power factor operation. DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) REFERENCE DRAWING PC1 000 200 500 REFERENCE DRAWING 1 0.438" 0.199 Dia Thru 4 Holes 500K A .203" Dia Thru 4 Holes A B MAX B 0.594" 2.812˝ 0.250 Dia Thru 2 Holes 502K 518 2.438˝ 1.750" 2.188" 3.500˝ 3.938˝ 700 2.188" 2.625" 718 WIRING DIAGRAMS Bracket S Wiring Diagram 1 Wiring Diagram 4 Wiring Diagram 4A M 3.35” 4.60” S 0.25” 0.25” 120V STARTER Cap 120V (Blue) 1 3 Cap 3 STARTER (Yellow) Cap (Black) 277V Lamp Eyelet 208V Cap Cap 1 3 (Yellow) L W 4.00” 0.75” 5.25” 1.25” 240V (Blue) 3 208V 120V BRef. Dwg. 1 PC1 Lamp Eyelet (Yellow) Cap 240V (Black) M L 277V (Black) 347V 277V Lamp Eyelet 3 (Blue) 1 3 STARTER 2 2 2 Com To Lamp Shell Com (Yellow) To Lamp Shell Com To Lamp Shell (Yellow) (Yellow) See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Wiring Diagram 17 Wiring Diagram 6 Cap Cap (AUX) INC LAMP W MAX PERMISSIBLE (White) (Black) or (Yellow) 120V Blue/White Trace 240V Lamp Eyelet (Blue) 3 1 3 208V STARTER 120V 2 To Lamp Shell Com (White) or (Yellow) Com (Yellow) PAGE 5-19 Cap Cap (Red) (Red) IGNITOR 277V Line (Blue) Yellow/Red Trace Com (Yellow) FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL W Specification Sheet Catalog Number: M150MLTLC3M Document #: 010-9705-03 Date: 12/06/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 120 208 240 277 150W METAL HALIDE 150W MH M102 or M142 120/208/240/277 5% 60 HZ 10/5/5/4 HX-HPF 180° C 16 MF 300 VOLTS 90° C 005-1498-MF MH100-3A Cu/Cu Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 11310-543 Yes Yes UL & CSA 10 FT Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Power Factor Oprtng Open Start High 1.57 3.32 1.70 High 0.91 1.93 1.00 High 0.81 1.66 0.80 High 0.74 1.48 0.77 Input Watts 185 185 185 185 Open Circuit Volts 245 245 245 245 Drop Min. UL Out Start Temp. Volts Temp. Code 75 -30°C D 125 -30°C D 150 -30°C D 160 -30°C D Reference Drawing Test Limits Line Volt 120 208 240 277 Power Factor High High High High Line Current, Amps Operating Open Min. Max. Min. Max. 1.43 1.74 1.66 4.75 0.83 1.01 0.97 2.76 0.74 0.90 0.83 2.37 0.67 0.82 0.74 2.12 Open Circuit Short Voltage (V) Min. Max. Min. Max. 0.85 1.25 230 265 0.50 0.72 230 265 0.42 0.62 230 265 0.40 0.60 230 265 Short Circuit Current (A) Min. Max. 1.90 2.40 1.90 2.40 1.90 2.40 1.90 2.40 Physical Characteristics Overall Dimensions, Inches Mounting Holes (In.) Bracket CapacitorDim. Ballast Lead Over Mntng Dim Net Length Length Height Stack Coils Diam Length Width Length Width Dia. Length Weight Inches 3.94 2.81 2.38 3.88 0.25 3.50 2.44 1.56 2.69 7.25 12-14 For samples, contact your Universal Lighting Technologies Representative. Application and Performance Specification Information Subject to Change without Notification. 1-800-BALLAST www.universalballast.com MH 150 HID CORE & COIL BALLASTS • 60 Hz • Minimum starting temperature: -30° C • High Power Factor models available WATT Nom Max Open Circuit Watts Input Circuit Fuse Wir Input Catalog* Volts Number Type Input Current Voltage Rating Dia (1) 150 WATT M102 METAL HALIDE LAMP - Medium Base 120 or 3.32 10 277 or M150TRILC3M HX-HPF 185 1.48 245 4 4A 347 0.65 2 120 or 3.32 10 208 or 1.93 5 M150MLTLC3M HX-HPF 185 245 4 240 or 1.66 5 277 1.48 4 480-120 M15048TLC3M HX-HPF 180 1.00 245 2 6 (1) 150 WATT M81 METAL HALIDE LAMP - Double Ended 120 or 3.32 10 208 or 1.93 5 245 17 M150MLTLC3D HX-HPF 185 240 or 1.66 5 277 1.48 4 DESCRIPTION Dimensions Capacitor Min Mfd Volt Ignitor Dry Film Dia Ht Total Weight (lbs.) Oil Filled Oval Ht Max UL Catalog Distance Bench Number to lamp (ft) Top Rise Ref Dwg A B PC1 2.3 3.9 16 280 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 D PC1 2.3 3.9 16 300 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 D PC1 2.3 3.9 16 280 1.6 2.7 1.56x2.69 2.7 7.3 MH100-3A 10 F PC1 2.3 3.9 16 280 1.6 2.7 1.56x2.69 2.7 7.3 MH70-3B 10 D REFERENCE DRAWING PC1 SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) METAL HALIDE 000 200 500 0.199 Dia Thru 4 Holes A B MAX 500K 2.812˝ 0.250 Dia Thru 2 Holes 502K 518 700 2.438˝ 3.500˝ 3.938˝ 718 Wiring Diagram 4A Wiring Diagram 4 347V 3 M 4.60” S 0.25” 120V Cap 277V Lamp Eyelet 208V Cap L W 5.25” 1.25” 240V (Yellow) BRef. Dwg. PC1 Cap M L (Black) 277V 120V (Blue) 1 3 (Black) S Cap Bracket (Yellow) W Lamp Eyelet 3 (Blue) 1 3 STARTER STARTER 2 To Lamp Shell Com 2 (Yellow) To Lamp Shell Com See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. (Yellow) Wiring Diagram 6 Wiring Diagram 17 Cap (AUX) Cap 120V INC LAMP W MAX PERMISSIBLE Lamp Eyelet Blue/White Trace 240V (Blue) 3 1 3 208V STARTER 120V 2 Cap Cap (Red) (Red) IGNITOR 277V Line (White) (Black) or (Yellow) HID CORE & COIL WIRING DIAGRAMS (Blue) Yellow/Red Trace To Lamp Shell Com (Yellow) Com (White) or (Yellow) PAGE 5-20 Com (Yellow) FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDE Input Volts Catalog* Number • 60 Hz • Minimum starting temperature: -30° C • Feature CWA design Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Type Input Current Voltage Rating Dia Dwg A B (1) 175 WATT M57, M107 METAL HALIDE OR H39 MERCURY LAMPS 277 M175277AC3M CWA 213 0.78 310 2 18 2 2.3 480-120 M17548TAC3M CWA 213 0.51 310 1.5 19 PC1 2.8 120 or 1.80 5 277 or M175TRIAC3M CWA 213 0.78 310 2 23 PC1 2.2 347 0.62 2 120 or 1.80 5 208 or M175MLTAC3M CWA 213 1.10 3 310 21 PC1 2.2 240 or 0.90 3 277 0.78 2 120 or 208 1.90 5 208 1.10 3 208 or 240 or M175ML5AC3M CWA 208 0.95 300 3 44 PC1 2.3 277 or 208 0.85 2 480 210 0.50 1.5 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) MH 175 WATT Capacitor Oil Filled Oval Ht Max UL Catalog Distance Bench Number to lamp (ft) Top Rise Min Mfd Volt Dry Film Dia Ht 3.5 4.2 10 400 10 400 1.6 1.6 2.7 2.7 1.56x2.69 1.56x2.69 2.7 2.7 6.8 6.8 n/a n/a n/a n/a 3.7 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a 3.6 10 400 1.6 2.7 1.56x2.69 2.7 6.8 n/a n/a REFERENCE DRAWING PC1 A B .250" Dia Thru 2 Holes 2.812˝ 500K 0.250 Dia Thru 2 Holes 502K 2.437" 2.438˝ 3.500˝ 3.938˝ 2.812" 1.218" 518 3.500" 3.938" 700 718 WIRING DIAGRAMS Wiring Diagram 19 Line Cap (Red) Line HID CORE & COIL Wiring Diagram 18 Cap (Red) 120V (AUX) INC LAMP W MAX W Bracket S M L BRef. Dwg. PC1, 2 L W 5.25” 1.25” Com (White) or Com (Yellow) Wiring Diagram 23 See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. 277V 240V 208V Cap (Red) Cap (Red) 120V 120V Com (Yellow) Wiring Diagram 44 347V 277V S 0.25” Com (Yellow) or (White) PERMISSIBLE Com (Yellow) or (White) Wiring Diagram 21 M 4.60” B 0.438" .199" Dia Thru 4 Holes A B MAX A D B B D A B A A REFERENCE DRAWING 2 0.199 Dia Thru 4 Holes 000 200 500 Ignitor Total Weight (lbs.) Com (Yellow) PAGE 5-21 Com (White) Com (White) FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDE FEATURING MULTI-5™ Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A B (1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMPS - 4.75” Frame 120 or 2.50 8 208 or 1.40 5 305 4 44 PC2 1.8 3.6 240 or M250ML5AC4M CWA 293 1.30 277 or 1.10 3 480 0.65 2 120 or 3.05 8 CWA 293 1.25 305 3 23 PC2 1.6 3.6 277 or M250TRIAC4M 347 1.05 3 120 or 3.05 8 1.65 5 208 or 21 PC2 1.6 3.2 CWA 293 305 M250MLTAC4M 240 or 1.55 4 277 1.25 3 480-120 M25048TAC4M CWA 293 0.70 305 2 18 PC2 1.6 3.2 DESCRIPTION MH 250 • 60 HZ. • Minimum Starting Temperature: -30° C • Feature CWA Design WATT Capacitor Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise Min Mfd Volt Dry Film Dia Ht 15 400 1.6 3.6 1.91x2.91 2.7 10.8 n/a n/a A 15 400 1.6 3.6 1.91x2.91 2.7 9.5 n/a n/a A 15 400 1.6 3.6 1.91x2.91 2.7 9.5 n/a n/a B 15 400 1.6 3.6 1.91x2.91 2.7 9.5 n/a n/a B SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Distributor Ballast Lamp Replacement Kit (see pg. 5-12) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 REFERENCE DRAWING PC2 0.250 Dia Thru 4 Holes A B MAX 500K 4.250˝ 502K 0.250 Dia Thru 2 Holes 518 3.875˝ 4.375˝ 4.750˝ 555K 700 718 WIRING DIAGRAMS HID CORE & COIL Wiring Diagram 18 Wiring Diagram 21 277V W Bracket S L W 5.25” 1.25” Line 240V 208V Cap (Red) 120V M L BRef. Dwg. PC 2 Cap (Red) Com (White) M 4.60” S 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. or Com (Yellow) Com (Yellow) Wiring Diagram 23 Com (Yellow) Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-23 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH 250 HID CORE & COIL BALLASTS • 60 HZ. • Minimum Starting Temperature: -30° C • Feature CWA Design WATT METAL HALIDE Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 250 WATT M58 METAL HALIDE OR H37 MERCURY LAMP - 4” Frame 480-120 M25048TAC3M CWA 294 0.64 280 2 19 PC1 3.0 120 or 3.05 8 305 3 23 PC1 3.0 277 or M250TRIAC3M CWA 293 2.10 347 1.05 3 120 or 2.60 8 208 or M250MLTAC3M CWA 294 1.58 5 280 21 PC1 3.0 240 or 1.30 4 277 1.12 3 120 or 2.60 8 208 or 1.60 5 240 or M250ML5AC3M CWA 280 1.30 290 4 44 PC1 3.0 277 or 1.20 3 480 0.70 2 DESCRIPTION Capacitor Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a D 4.5 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a D 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a 4.3 15 400 1.6 3.6 1.91x2.91 2.7 9.0 n/a n/a C D C C B B B C C SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Distributor Ballast Lamp Replacement Kit (see pg. 5-12) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 REFERENCE DRAWING PC1 500K 0.199 Dia Thru 4 Holes 502K A B MAX 518 2.812˝ 0.250 Dia Thru 2 Holes 555K 700 2.438˝ 3.500˝ 3.938˝ 718 HID CORE & COIL WIRING DIAGRAMS W Bracket S Wiring Diagram 19 Wiring Diagram 21 Line M L BRef. Dwg. PC1 L W 5.25” 1.25” 277V Cap (Red) 240V 120V (AUX) M 4.60” S 0.25” 208V INC LAMP W MAX Cap (Red) 120V PERMISSIBLE Com (Yellow) Com (Yellow) or (White) or (White) Com (Yellow) Com (Yellow) See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Wiring Diagram 23 Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-22 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH 400 • 60 Hz • Minimum Starting Temperature: -30° C • CWA Designs WATT HID CORE & COIL BALLASTS METAL HALIDE Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP 120 M400120AC4M CWA 458 4.00 300 10 18 PC2 2.0 480-120 M40048TAC4M CWA 458 1.00 300 5 19 PC2 2.0 120 4.00 10 277 M400TRIAC4M CWA 458 1.70 300 5 23 PC2 2.0 347 1.35 5 120 or 4.00 10 208 or 2.30 8 M400MLTAC4M CWA 458 300 21 PC2 2.0 240 or 2.00 5 277 1.70 5 120 or 4.00 10 208 or 2.30 8 300 21 PC2 2.0 M400MLTAC4L CWA 440 240 or 2.00 5 277 1.70 5 120 or 4.00 10 208 or 2.30 8 240 or M400ML5AC4M CWA 458 2.00 300 5 44 PC2 2.0 277 or 1.70 5 480 1.00 5 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Distributor Ballast Lamp Replacement Kit (see pg. 5-12) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) Capacitor Ignitor Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 3.9 3.9 24 400 24 400 1.8 1.8 3.6 3.6 1.91x2.91 1.91x2.91 3.1 3.1 11.2 11.2 n/a n/a n/a n/a 3.9 24 400 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a 3.9 24 360 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a 3.9 24 400 1.8 3.6 1.91x2.91 3.1 13.0 n/a n/a A n/a E D E D E 3.9 24 400 1.8 3.6 Oil Filled Oval Ht Total Weight (lbs.) 1.91x2.91 3.1 11.2 n/a C E C C B C D D E REFERENCE DRAWING PC2 000 200 500 0.250 Dia Thru 4 Holes A B MAX 500K 4.250˝ 0.250 Dia Thru 2 Holes 502K 518 3.875˝ 4.375˝ 4.750˝ 555K 700 718 WIRING DIAGRAMS HID CORE & COIL W Bracket S Wiring Diagram 18 Wiring Diagram 21 Wiring Diagram 19 277V Cap M L BRef. Dwg. PC2 L W 7.75” 2.75” M 6.10” Line (Red) Line 240V 208V 120V (AUX) S 0.25” Cap (Red) 120V INC LAMP W MAX Com See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Cap (Red) (White) or Com (Yellow) PERMISSIBLE Com (Yellow) or (White) Wiring Diagram 23 Com (Yellow) or (White) Com Com (Yellow) (Yellow) Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-24 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MH 400 • 60 Hz • Minimum Starting Temperature: -30° C • CWA Designs WATT HID CORE & COIL BALLASTS METAL HALIDE Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 400 WATT M59 METAL HALIDE OR H33 MERCURY LAMP 120 M400120AC4M CWA 458 4.00 300 10 18 PC2 2.0 480-120 M40048TAC4M CWA 458 1.00 300 5 19 PC2 2.0 120 4.00 10 277 M400TRIAC4M CWA 458 1.70 300 5 23 PC2 2.0 347 1.35 5 120 or 4.00 10 208 or 2.30 8 M400MLTAC4M CWA 458 300 21 PC2 2.0 240 or 2.00 5 277 1.70 5 120 or 4.00 10 208 or 2.30 8 300 21 PC2 2.0 M400MLTAC4L CWA 440 240 or 2.00 5 277 1.70 5 120 or 4.00 10 208 or 2.30 8 240 or M400ML5AC4M CWA 458 2.00 300 5 44 PC2 2.0 277 or 1.70 5 480 1.00 5 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Distributor Ballast Lamp Replacement Kit (see pg. 5-12) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) Capacitor Ignitor Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 3.9 3.9 24 400 24 400 1.8 1.8 3.6 3.6 1.91x2.91 1.91x2.91 3.1 3.1 11.2 11.2 n/a n/a n/a n/a 3.9 24 400 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a 3.9 24 360 1.8 3.6 1.91x2.91 3.1 11.2 n/a n/a 3.9 24 400 1.8 3.6 1.91x2.91 3.1 13.0 n/a n/a A n/a E D E D E 3.9 24 400 1.8 3.6 Oil Filled Oval Ht Total Weight (lbs.) 1.91x2.91 3.1 11.2 n/a C E C C B C D D E REFERENCE DRAWING PC2 000 200 500 0.250 Dia Thru 4 Holes A B MAX 500K 4.250˝ 0.250 Dia Thru 2 Holes 502K 518 3.875˝ 4.375˝ 4.750˝ 555K 700 718 WIRING DIAGRAMS HID CORE & COIL W Bracket S Wiring Diagram 18 Wiring Diagram 21 Wiring Diagram 19 277V Cap M L BRef. Dwg. PC2 L W 7.75” 2.75” M 6.10” Line (Red) Line 240V 208V 120V (AUX) S 0.25” Cap (Red) 120V INC LAMP W MAX Com See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Cap (Red) (White) or Com (Yellow) PERMISSIBLE Com (Yellow) or (White) Wiring Diagram 23 Com (Yellow) or (White) Com Com (Yellow) (Yellow) Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-24 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS METAL HALIDE • 60 Hz • Minimum Starting Temperature: -30° C • CWA Designs Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 1000 WATT M47 METAL HALIDE OR H36 MERCURY LAMP 120 M1000120AC5M CWA 1080 9.00 425 20 18 PC3 2.8 M1000208AC5M CWA 1080 5.20 425 15 18 PC3 2.8 208 M1000240AC5M CWA 1080 4.40 425 10 18 PC3 2.8 240 277 M1000277AC5M CWA 1080 3.90 425 10 18 PC3 2.8 M1000480AC5M CWA 1080 3.30 425 10 19 PC3 2.8 480 480-120 M100048TAC5M CWA 1080 2.30 420 10 19 PC3 2.8 120 or 9.20 20 CWA 1080 4.00 420 10 23 PC3 2.8 277 or M1000TRIAC5M 347 3.20 10 120 or 9.20 20 5.30 15 208 or 21 PC3 2.8 CWA 1080 420 M1000MLTAC5M 240 or 4.60 10 277 4.00 10 120 or 9.00 20 208 or 5.20 15 240 or M1000ML5AC5M CWA 1080 4.40 425 10 44 PC3 2.8 277 or 3.90 10 480 2.30 10 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) W Bracket B Dry Film Dia Ht 4.6 4.6 4.6 4.6 4.6 4.6 24 24 24 24 24 24 480 480 480 480 480 480 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 3.9 3.9 3.9 3.9 3.9 3.9 22.0 22.0 22.0 22.0 22.0 22.0 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 4.6 24 480 n/a n/a 1.91x2.91 3.9 24..0 n/a n/a 4.7 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a D n/a F B B B B 4.6 24 480 n/a n/a Oil Filled Oval Ht Max UL Catalog Distance Bench Number to lamp (ft) Top Rise Min Mfd Volt 1.91x2.91 3.9 22.0 n/a D B B B B C E C C 0.250 Dia Thru 8 Holes 0.250 Dia Thru 2 Holes 4.250˝ 3.875˝ 4.375˝ 5.375˝ 5.750˝ 518 700 718 S WIRING DIAGRAMS Wiring Diagram 19 Line Cap (Red) Wiring Diagram 21 Cap (Red) 120V (AUX) 208V INC LAMP W MAX Com (White) or 277V 240V S 0.25” Com (Yellow) PERMISSIBLE Com (Yellow) or (White) See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Wiring Diagram 23 Cap (Red) 120V Com (Yellow) or (White) Com Com (Yellow) (Yellow) Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-25 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL Wiring Diagram 18 M 6.10” Ignitor Total Weight (lbs.) A Line L W 7.75” 2.75” Capacitor B MAX 502K M L BRef. Dwg. PC3 WATT REFERENCE DRAWING PC3 000 200 500 500K MH 1000 HID CORE & COIL BALLASTS METAL HALIDE • 60 Hz • Minimum Starting Temperature: -30° C • CWA Designs Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Input Catalog* Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 1000 WATT M47 METAL HALIDE OR H36 MERCURY LAMP 120 M1000120AC5M CWA 1080 9.00 425 20 18 PC3 2.8 M1000208AC5M CWA 1080 5.20 425 15 18 PC3 2.8 208 M1000240AC5M CWA 1080 4.40 425 10 18 PC3 2.8 240 277 M1000277AC5M CWA 1080 3.90 425 10 18 PC3 2.8 M1000480AC5M CWA 1080 3.30 425 10 19 PC3 2.8 480 480-120 M100048TAC5M CWA 1080 2.30 420 10 19 PC3 2.8 120 or 9.20 20 CWA 1080 4.00 420 10 23 PC3 2.8 277 or M1000TRIAC5M 347 3.20 10 120 or 9.20 20 5.30 15 208 or 21 PC3 2.8 CWA 1080 420 M1000MLTAC5M 240 or 4.60 10 277 4.00 10 120 or 9.00 20 208 or 5.20 15 240 or M1000ML5AC5M CWA 1080 4.40 425 10 44 PC3 2.8 277 or 3.90 10 480 2.30 10 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) W Bracket B Dry Film Dia Ht 4.6 4.6 4.6 4.6 4.6 4.6 24 24 24 24 24 24 480 480 480 480 480 480 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 1.91x2.91 3.9 3.9 3.9 3.9 3.9 3.9 22.0 22.0 22.0 22.0 22.0 22.0 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 4.6 24 480 n/a n/a 1.91x2.91 3.9 24..0 n/a n/a 4.7 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a D n/a F B B B B 4.6 24 480 n/a n/a Oil Filled Oval Ht Max UL Catalog Distance Bench Number to lamp (ft) Top Rise Min Mfd Volt 1.91x2.91 3.9 22.0 n/a D B B B B C E C C 0.250 Dia Thru 8 Holes 0.250 Dia Thru 2 Holes 4.250˝ 3.875˝ 4.375˝ 5.375˝ 5.750˝ 518 700 718 S WIRING DIAGRAMS Wiring Diagram 19 Line Cap (Red) Wiring Diagram 21 Cap (Red) 120V (AUX) 208V INC LAMP W MAX Com (White) or 277V 240V S 0.25” Com (Yellow) PERMISSIBLE Com (Yellow) or (White) See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Wiring Diagram 23 Cap (Red) 120V Com (Yellow) or (White) Com Com (Yellow) (Yellow) Wiring Diagram 44 347V 277V Cap (Red) 120V Com (White) Com (White) PAGE 5-25 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL Wiring Diagram 18 M 6.10” Ignitor Total Weight (lbs.) A Line L W 7.75” 2.75” Capacitor B MAX 502K M L BRef. Dwg. PC3 WATT REFERENCE DRAWING PC3 000 200 500 500K MH 1000 MH 1500 HID CORE & COIL BALLASTS • 60 Hz • Minimum Starting Temperature: -30° C • CWA Designs WATT METAL HALIDE Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 1500 WATT M48 METAL HALIDE LAMP 480-120 M150048TAC5M CWA 1610 3.50 450 10 19 PC3 4.3 120 or 14.00 40 277 or M1500TRIAC5M CWA 1610 6.00 450 20 23 PC3 4.3 347 4.50 15 120 or 14.00 40 208 or M1500MLTAC5M CWA 1610 8.00 25 21 PC3 4.3 450 240 or 7.00 20 277 6.00 20 480 M1500480AC5M CWA 1610 3.50 450 10 19 PC3 4.3 DESCRIPTION Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 6.4 32 525 n/a n/a 1.97x3.66 3.9 29.5 n/a n/a E 6.4 32 500 n/a n/a 1.97x3.66 3.9 29.5 n/a n/a G 6.4 32 525 n/a n/a 1.97x3.66 3.9 30.0 n/a n/a 6.3 32 525 n/a n/a 1.97x3.66 3.9 29.5 n/a n/a F E F F E SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) HID CORE & COIL Capacitor 000 200 500 REFERENCE DRAWING PC3 0.250 Dia Thru 8 Holes A B MAX 500K 502K 0.250 Dia Thru 2 Holes 518 4.250˝ 700 3.875˝ 4.375˝ 5.375˝ 5.750˝ 718 WIRING DIAGRAMS W Bracket S M L BRef. Dwg. PC3 L W 7.75” 2.75” Wiring Diagram 19 Line Wiring Diagram 21 Wiring Diagram 23 277V Cap (Red) 347V 240V M 6.10” S 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. 120V (AUX) 208V INC LAMP W MAX 277V Cap (Red) 120V PERMISSIBLE Com (Yellow) Com (Yellow) or (White) or (White) Com (Yellow) PAGE 5-26 Cap (Red) 120V Com (Yellow) Com Com (White) (White) FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) M1000MLTAC5M 1000W Metal Halide 60Hz CWA Specification Sheet 120 208 240 277 ±10% ±10% ±10% ±10% ±10% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 1080 W 1080 W 1080 W 1080 W 1080 W 425 V 425 V 425 V 425 V 425 V 8.95 5.15 4.50 3.90 Input Volts Regulation Line Volts Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating M47 / H36 277 V ( BLACK) CAP (RED) 240 V ( VIOLET) 208 V ( ORANGE) 120 V ( BLK/ YEL) Open Circuit 5.65 3.25 2.80 2.45 Starting 6.20 3.60 3.10 2.70 Recommended Fuse (Amps) 20 15 10 10 0 Lamp Dropout Voltage (Line) 75 V 130 V 150 V 170 V V COM ( YEL) UL Temperature Ratings Insulation Class COM ( YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) A D D D D -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C 24.0 uf 24.0 uf 24.0 uf 24.0 uf 24.0 uf 480 V 480 V 480 V 480 V 480 V 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 380 - 465 380 - 465 380 - 465 380 - 465 380 - 465 Secondary Current Shorted (A) 4.90 - 6.05 4.90 - 6.05 4.90 - 6.05 4.90 - 6.05 4.90 - 6.05 Input Operating Current (A) 8.15 - 10.00 4.45 - 5.50 4.05 - 5.00 3.50 - 4.35 - Input Open Circuit Current (A) 2.90 - 8.15 1.60 - 4.55 1.45 - 4.15 1.25 - 3.65 - Input Short Circuit Current (A) 4.85 - 7.35 2.90 - 4.40 2.40 - 3.65 2.10 - 3.20 - Rated Temp 90 °C 2.90 in 2.90 in 2.90 in 2.90 in 2.90 in Height: 3.90 in Dimension B 5.05 in 5.05 in 5.05 in 5.05 in 5.05 in Width / Diameter: 2.91 in Weight 22.0 lbs 22.0 lbs 22.0 lbs 22.0 lbs 22.0 lbs Lead Lengths (inches) Coil Material (Pri. / Sec.): 12-14 12-14 12-14 12-14 12-14 Cu / Al Cu / Al Cu / Al Cu / Al Cu / Al Temperature Code MIN. Starting Temperature CAPACITOR Specifications Microfarads Volts (min.) 60Hz Test Procedures High Potential Test 1 Minute Core and Coil Specifications Dimension A Document #: 010-11022-02 Date: 2/16/2006 Status: Production Replaces Catalog #: M1000MLTAC5M LAMP (RED/BLK) 0.250 Dia Thru 8 Holes B MAX 4.250" 0.250 Dia Thru 2 Holes 3.875" 4.375" 5.375" 5.750" Reference Drawing Capacitor: 005-2779-MF Ignitor: None This Ballast does not require a Ignitor For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 3/29/2006 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com M1500MLTAC5M 1500W Metal Halide 60Hz CWA Specification Sheet 120 208 240 277 ±10% ±10% ±10% ±10% ±10% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 1615 W 1615 W 1615 W 1615 W 1615 W 455 V 455 V 455 V 455 V 455 V 14.30 8.30 7.20 6.20 Input Volts Regulation Line Volts Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating M48 277 V ( BLACK) CAP (RED) 240 V ( VIOLET) 208 V ( ORANGE) 120 V ( BLK/ YEL) Open Circuit 9.40 5.40 4.70 4.05 Starting 6.35 3.65 3.20 2.75 Recommended Fuse (Amps) 40 25 20 20 0 Lamp Dropout Voltage (Line) 70 V 120 V 140 V 160 V V COM ( YEL) UL Temperature Ratings Insulation Class COM ( YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) A F G F E -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C 32.0 uf 32.0 uf 32.0 uf 32.0 uf 32.0 uf 525 V 525 V 525 V 525 V 525 V 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 405 - 495 405 - 495 405 - 495 405 - 495 405 - 495 Secondary Current Shorted (A) 7.45 - 9.15 7.45 - 9.15 7.45 - 9.15 7.45 - 9.15 7.45 - 9.15 Input Operating Current (A) 12.60 - 15.40 7.80 - 9.60 6.30 - 7.75 5.50 - 6.80 - Input Open Circuit Current (A) 4.65 - 13.65 2.70 - 7.90 2.30 - 6.85 2.00 - 5.95 - Input Short Circuit Current (A) 4.85 - 7.30 2.10 - 3.25 2.40 - 3.65 2.10 - 3.25 - Rated Temp 90 °C 4.40 in 4.40 in 4.40 in 4.40 in 4.40 in Height: 3.88 in Dimension B 6.40 in 6.40 in 6.40 in 6.40 in 6.40 in Width / Diameter: 2.91 in Weight 30.0 lbs 30.0 lbs 30.0 lbs 30.0 lbs 30.0 lbs Lead Lengths (inches) Coil Material (Pri. / Sec.): 12-14 12-14 12-14 12-14 12-14 Cu / Cu Cu / Cu Cu / Cu Cu / Cu Cu / Cu Temperature Code MIN. Starting Temperature CAPACITOR Specifications Microfarads Volts (min.) 60Hz Test Procedures High Potential Test 1 Minute Core and Coil Specifications Dimension A Document #: 010-11756-00 Date: 5/8/2006 Status: Production Replaces Catalog #: 1130-99R LAMP (RED/BLK) 0.250 Dia Thru 8 Holes B MAX 4.250" 0.250 Dia Thru 2 Holes 3.875" 4.375" 5.375" 5.750" Reference Drawing Capacitor: 005-1474-MF Ignitor: None This Ballast does not require a Ignitor For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 4/21/2006 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com M175MLTAC3M 175W Metal Halide 60Hz CWA Specification Sheet 120 208 240 277 ±10% ±10% ±10% ±10% ±10% Lamp Watts ±10% ±10% ±10% ±10% ±10% Power Factor (min) 90% 90% 90% 90% 90% 213 W 213 W 213 W 213 W 213 W 305 V 305 V 305 V 305 V 305 V 1.90 1.10 0.95 0.85 Input Volts Regulation Line Volts Input Watts NOM. Open Circuit Voltage Line Current (Amps) Operating M57 / M107 / H39 277 V ( BLACK) CAP (RED) 240 V ( VIOLET) 208 V ( ORANGE) 120 V ( BLK/ YEL) Open Circuit 1.70 0.95 0.85 0.70 Starting 1.40 0.80 0.70 0.60 Recommended Fuse (Amps) 5 3 3 2 0 Lamp Dropout Voltage (Line) 60 V 100 V 120 V 135 V V COM ( YEL) UL Temperature Ratings Insulation Class Temperature Code MIN. Starting Temperature COM ( YEL) Wiring Diagram H (180°C) H (180°C) H (180°C) H (180°C) H (180°C) A C B C -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C A 10 uf 10 uf 10 uf 10 uf 10 uf 400 V 400 V 400 V 400 V 400 V 60Hz Test Procedures High Potential Test 1 Minute 2000 V 2000 V 2000 V 2000 V 2000 V High Potential Test 1 Second 2500 V 2500 V 2500 V 2500 V 2500 V Secondary Open Ckt Voltage (V) 275 - 335 275 - 335 275 - 335 275 - 335 275 - 335 Secondary Current Shorted (A) 1.55 - 1.90 1.55 - 1.90 1.55 - 1.90 1.55 - 1.90 1.55 - 1.90 Input Operating Current (A) 1.70 - 2.20 1.00 - 1.25 0.85 - 1.10 0.75 - 0.95 - Input Open Circuit Current (A) 0.80 - 2.45 0.45 - 1.40 0.40 - 1.25 0.35 - 1.05 - Input Short Circuit Current (A) 1.05 - 1.60 0.60 - 0.90 0.50 - 0.80 0.45 - 0.70 - Temp Rating: 90 °C 2.20 in 2.20 in 2.20 in 2.20 in 2.20 in Height: 2.69 in Dimension B 3.60 in 3.60 in 3.60 in 3.60 in 3.60 in Width / Diameter: 2.69 in Weight 6.10 lbs 6.10 lbs 6.10 lbs 6.10 lbs 6.10 lbs Lead Lengths (inches) Coil Material (Pri. / Sec.): 12-14 12-14 12-14 12-14 12-14 Cu / Al Cu / Al Cu / Al Cu / Al Cu / Al Document #: 010-10883-03 Date: 1/18/2007 Status: Production Replaces Catalog #: New Design 0.234 Dia Thru 4 Holes B MAX -22°F -30°C CAPACITOR Specifications Microfarads Volts (min.) Core and Coil Specifications Dimension A LAMP (RED/BLK) 2.812" 0.250 Dia Thru 2 Holes 2.438" 3.500" 3.938" Reference Drawing Capacitor: 005-1184-MF Ignitor: None This Ballast does not require a Ignitor For alternate capacitor construction consult sales Data is based upon tests performed by Universal Lighting Technologies in a controled environment and is representive of relative performance. Actual performance may vary depending on operating conditions. Specifications are subject to change without notice. 1/17/2007 Universal Lighting Technologies 26 Century Blvd. Suite 500 - Nashville, TN 37214 Phone 1-800-225-5278 Fax 1-800-206-0035 www.universalballast.com Specification Sheet Catalog Number: M250MLTAC3M Document #: 010-9652- 03 Date: 5/6/2004 Lamp Type ANSI Designation Line Voltage Regulation Frequency Recommended Fuse Circuit Type Insulation Class Capacitor Value Capacitor Volt Rating Capacitor Temp Rating Capacitor Part Number Lamp Starter Winding Material (Pri/Sec) FEATURES: Line Volt 120 208 240 277 250W METAL HALIDE 250W MH M58 or H37 120/208/240/277 10% 60 HZ 8/5/4/3 CWA 180° C 15MF 400 VOLTS 90° C 005-1185-MF N/A Cu/Al Replaces Catalog # Samples Available Production Available Agency Certification Maximum Distance to Lamp 1130-92 Yes Yes UL & CSA N/A Utilizes Precise-Wound Coils Electrical Characteristics Line Current in Amps Open Power Input Circuit Factor Oprtng Open Start Watts Volts High 2.65 2.50 1.88 297 315 High 1.50 1.58 1.15 297 315 High 1.30 1.25 0.95 297 315 High 1.13 1.10 0.86 297 315 Drop Out Volts 65 105 125 150 Min. Start Temp. -30°C -30°C -30°C -30°C UL Temp. Code D D D D Reference Drawing Line Volt 120 208 240 277 Power Factor High High High High Test Limits Line Current, Amps Open Circuit Operating Open Short Voltage (V) Min. Max. Min. Max. Min. Max. Min. Max. 2.41 2.94 1.25 3.58 1.42 2.40 288 350 1.37 1.67 0.79 2.26 0.84 1.42 288 350 1.18 1.44 0.63 1.79 0.74 1.24 288 350 1.03 1.25 0.55 1.57 0.56 0.95 288 350 Physical Characteristics Mounting Holes (In.) Overall Dimensions, Inches Length 3.94 Height 2.81 Stack 3.00 Over Coils 4.25 Diam 0.25 Length 3.50 Width 2.44 Bracket CapacitorDim. Mntng Dim Length Width Dia. Length 1.91 2.69 Application and Performance Specification Information Subject to Change without Notification. For samples, contact your Universal Lighting Technologies Representative. 1-800-BALLAST Short Circuit Current (A) Min. Max. 2.24 2.85 2.24 2.85 2.24 2.85 2.24 2.85 www.universalballast.com Ballast Net Weight 9.00 Lead Length Inches 12-14 MERCURY 100 WATT Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 100 WATT H38 OR H44 MERCURY LAMP 480-120 H10048TAC3M CWA 124 0.28 240 1 19 PC1 1.3 120 or 1.05 3 208 or 0.60 2 21 PC1 1.3 CWA 125 250 H100MLTAC3M 240 or 0.52 2 277 0.45 2 120 or 1.08 3 CWA 120 0.45 240 2 23 PC1 1.4 277 or H100TRIAC3M 347 0.36 1 DESCRIPTION MERCURY Capacitor Min Mfd Volt B Ignitor Dry Film Dia Ht Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise 2.5 10 280 1.4 2.7 1.31x2.16 2.7 4.0 n/a n/a A 2.5 10 280 1.4 2.7 1.31x2.16 2.7 4.0 n/a n/a A 2.7 10 280 1.2 2.7 1.31x2.16 2.7 3.7 n/a n/a A SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) HID CORE & COIL HID CORE & COIL BALLASTS • 60 Hz • Minimum Starting Temperature: -30° C • CWA, Normal and High Power Factor models available 000 200 500 REFERENCE DRAWING PC1 0.199 Dia Thru 4 Holes A B MAX 500K 2.812˝ 502K 0.250 Dia Thru 2 Holes 518 2.438˝ 700 3.500˝ 3.938˝ 718 WIRING DIAGRAMS Wiring Diagram 19 W Bracket S L W 5.25” 1.25” Wiring Diagram 23 Wiring Diagram 21 Cap (Red) 277V 347V 240V M L BRef. Dwg. PC1 Line 277V 120V (AUX) 208V INC LAMP W MAX M 4.60” S 0.25” PERMISSIBLE Com (Yellow) or (White) Cap (Red) 120V Cap (Red) 120V Com (Yellow) or (White) Com (Yellow) Com (Yellow) Com (White) Com (White) See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. PAGE 5-42 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS MERCURY Input Volts Catalog* Number 240 277 244 (1) 175 WATT H39 MERCURY LAMP R-NPF 2.05 240 192 1033-23S 9 R-HPF 3 1.08 R-NPF 1.90 277 192 1033-15S 9 R-HPF 3 1.25 480-120 H17548TAC3M CWA 205 0.75 120 or 1.75 1.00 208 or CWA 202 H175MLTAC3M 240 or 0.86 277 0.75 120 or 1.90 277 or H175TRIAC3M CWA 205 0.80 347 0.64 3 9 • 60 Hz • Minimum starting temperature: -30° C • CWA design or reactor models available Nom Dimensions Max Open Circuit Watts Input Circuit Fuse Wir Ref Type Input Current Voltage Rating Dia Dwg A B (1) 125 WATT H42 MERCURY LAMP R-NPF 1.65 240 139 1033-113S R-HPF 3 0.90 R-NPF 1.55 277 141 1033-111S R-HPF 3 1.05 120 or 1.45 0.85 208 or CWA 160 H125MLTAC3M 240 or 0.70 277 0.62 240 277 243 235 255 5 3 5 3 5 3 3 2 8 5 8 5 2 5 3 3 2 5 2 2 MERCURY 125-175 WATT Capacitor Min Mfd Volt Ignitor Dry Film Dia Ht Oil Filled Oval Ht n/a 1.6 n/a 1.6 n/a 2.7 n/a 2.7 n/a 1.31x2.16 n/a 1.31x2.16 n/a 3.1 n/a 3.1 1.6 2.7 1.31x2.16 3.1 17.5 300 n/a 1.6 n/a 1.6 1.6 n/a 2.7 n/a 2.7 3.6 n/a 1.31x2.16 n/a 1.31x2.16 1.56x2.69 n/a 3.1 n/a 3.1 3.1 2.9 17.5 300 1.6 3.6 1.56x2.69 3.0 17.5 240 1.6 2.7 1.56x2.69 24 1 1.5 2.5 10 240 24 1 1.5 2.5 10 277 21 PC1 3.0 5.0 13 280 24 1 2.2 3.3 12 240 24 1 2.2 3.3 12 277 19 PC1 1.8 3.0 21 PC1 1.6 23 PC1 1.8 Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise 2.4 n/a n/a A 2.4 n/a n/a D 4.0 n/a n/a B 3.5 n/a n/a A 3.5 n/a n/a B 5.2 n/a n/a A 3.1 5.2 n/a n/a A 3.1 5.3 n/a n/a C Capacitors are available as an option for high power factor operation. Also can be used to operate (1) 150 watt S63 High Pressure Sodium lamp. Electrical characteristics will vary from those shown. REFERENCE DRAWING 1 REFERENCE DRAWING PC1 0.438" DESCRIPTION 000 200 500 B MAX 2.812˝ 0.250 Dia Thru 2 Holes 1.750" 2.188" 500K 2.188" 2.438˝ 502K WIRING DIAGRAMS Wiring Diagram 19 Wiring Diagram 21 700 277V Line Cap (Red) 240V 718 120V (AUX) 208V L W 4.00” 0.75” 5.25” 1.25” Cap (Red) 120V Com (Yellow) or (White) Com (Yellow) S Com (Yellow) Wiring Diagram 24 Wiring Diagram 23 M L BRef. Dwg. 1 PC1 HID CORE & COIL 518 PERMISSIBLE Com (Yellow) or (White) W 3.500˝ 3.938˝ 2.625" INC LAMP W MAX Bracket A 0.594" SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 0.199 Dia Thru 4 Holes B A .203" Dia Thru 4 Holes 347V M 3.35” 4.60” S 0.25” 0.25” Line 277V Lamp (Blue) Cap (Red) 120V See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Com Com (White) Com (White) PAGE 5-43 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) MERCURY 250 • 60 HZ • Minimum Starting Temperature: -30° C • Normal and High Power Factor, CWA designs WATT Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 250 WATT H37 MERCURY LAMP R-NPF 2.85 10 240 240 24 4 1.5 1033-24S 10 1.85 5 R-HPF 3 270 R-NPF 2.70 10 10 277 277 24 4 1.5 1033-16S 1.60 5 R-HPF 3 270 CWA 285 0.66 255 3 19 PC1 2.3 480-120 H25048TAC3M 120 or 2.55 8 1.50 5 208 or 21 PC1 2.3 CWA 275 250 240 or H250MLTAC3M 1.27 5 277 1.10 3 120 or 2.60 8 277 or H250TRIAC3M CWA 285 1.20 260 5 23 PC1 2.3 347 1.00 3 HID CORE & COIL BALLASTS MERCURY Capacitor B Min Mfd Volt Dry Film Dia Ht 3.0 17.5 240 1.6 3.6 Ignitor Oil Filled Oval Ht 1.56x2.69 Total Weight (lbs.) 3.1 5.5 Max UL Catalog Distance Bench Number to lamp (ft) Top Rise n/a n/a A 3.0 17.5 277 1.6 3.6 1.56x2.69 3.1 5.5 n/a n/a A 3.5 22.5 280 1.6 3.6 1.56x2.69 3.5 6.7 n/a n/a E 3.5 22.5 280 1.6 3.6 1.56x2.69 3.50 6.7 n/a n/a D 3.5 22.5 280 1.6 3.6 1.56x2.69 3.5 6.7 n/a n/a B Capacitors are available as an option for high power factor operation. Also can be used to operate (1) 215 watt S65 High Pressure Sodium lamp. Electrical characteristics will vary from those shown. 3 10 REFERENCE DRAWING PC1 DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) 000 200 500 REFERENCE DRAWING 4 0.656" .218" Dia Thru 4 Holes 0.199 Dia Thru 4 Holes A A B 0.843" B MAX 2.812˝ 0.250 Dia Thru 2 Holes 2.937" 500K 2.500" 502K 2.438˝ 3.500˝ 3.938˝ 3.125" 3.125" 3.750" 518 700 WIRING DIAGRAMS 718 Wiring Diagram 19 Wiring Diagram 21 HID CORE & COIL 277V Line Cap (Red) 240V 120V (AUX) W Bracket S L W 5.25” 1.25” Com (Yellow) or (White) Com (Yellow) M 4.60” S 0.25” Cap (Red) 120V PERMISSIBLE Com (Yellow) or (White) M L BRef. Dwg. PC1, 4 208V INC LAMP W MAX Com (Yellow) Wiring Diagram 24 Wiring Diagram 23 347V See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Line 277V Lamp (Blue) Cap (Red) 120V Com Com Com (White) (White) PAGE 5-44 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL BALLASTS • 60 Hz • Minimum starting temperature: -30° C • CWA, Normal and High Power Factor models available MERCURY Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 400 WATT H33 MERCURY LAMP R-NPF 4.60 10 240 430 240 24 4 1.7 1033-25S 11 R-HPF 3 2.60 5 R-NPF 4.25 10 277 430 277 24 4 1.7 1033-17S 11 R-HPF 3 2.40 5 480-120 H40048TAC4M CWA 458 1.05 245 5 19 PC2 1.6 120 H400120AC4M CWA 458 1.05 245 5 18 PC2 1.6 120 or 3.90 10 277 or H400TRIAC4M CWA 440 2.22 260 5 23 PC2 1.8 347 1.92 5 120 or 3.90 10 208 or 2.22 8 CWA 440 245 21 PC2 1.6 H400MLTAC4M 240 or 1.92 5 277 1.68 5 (1) 1000 WATT H36 MERCURY LAMP 480-120 H100048TAC5M CWA 1080 2.28 440 10 19 PC3 2.9 120 or 9.30 20 5.30 15 208 or 21 PC3 2.9 430 H1000MLTAC5M CWA 1080 240 or 4.50 10 277 4.00 10 3 10 MERCURY 400-1000 WATT Capacitor Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 3.2 22.5 240 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a B 3.2 22.5 277 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a C 3.4 3.4 35 240 35 240 1.6 1.8 3.6 3.6 1.91x2.91 1.91x2.91 3.1 3.1 9.5 9.5 n/a n/a n/a n/a C C 3.5 35 240 1.8 3.6 1.91x2.91 3.1 9.5 n/a n/a A 3.4 35 240 1.6 3.6 1.91x2.91 3.1 9.5 n/a n/a C 4.7 24 480 1.8 3.6 1.91x2.91 3.9 19.5 n/a n/a 4.7 24 480 n/a n/a 1.91x2.91 3.9 19.5 n/a n/a C B A B B Capacitors are available as an option for high power factor operation. Also can be used to operate (1) 215 watt S65 High Pressure Sodium lamp. Electrical characteristics will vary from those shown. DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) REFERENCE DRAWING PC2 000 200 500 A B 0.843" 4.250˝ 500K 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes 2.937" 502K 3.875˝ 4.375˝ 4.750˝ 518 4.250˝ 3.875˝ 2.500" 4.375˝ 5.375˝ 5.750˝ 3.125" 3.125" 3.750" 700 WIRING DIAGRAMS S Wiring Diagram 19 Line Cap (Red) Line Wiring Diagram 21 Cap (Red) M L S 0.25” 0.25” 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Com (White) or Com (Yellow) Wiring Diagram 23 240V 208V Cap (Red) 120V INC LAMP W MAX M 5.75” 6.10” 4.60” 277V PERMISSIBLE Com (Yellow) Com (Yellow) or (White) or (White) Com (Yellow) Com (Yellow) Wiring Diagram 24 347V Line 277V Lamp (Blue) Cap (Red) 120V Com Com (White) Com (White) PAGE 5-45 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL 718 Bracket L W 7.75” 1.25” 7.75” 2.75” 5.25” 1.25” 0.656" .218" Dia Thru 4 Holes A B MAX 120V (AUX) BRef. Dwg. PC2 PC3 4 REFERENCE DRAWING 4 0.250 Dia Thru 8 Holes 0.250 Dia Thru 4 Holes A B MAX Wiring Diagram 18 W REFERENCE DRAWING PC3 HID CORE & COIL BALLASTS MERCURY Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 400 WATT H33 MERCURY LAMP R-NPF 4.60 10 240 430 240 24 4 1.7 1033-25S 11 2.60 5 R-HPF 3 R-NPF 4.25 10 430 277 24 4 1.7 277 1033-17S 11 2.40 5 R-HPF 3 480-120 H40048TAC4M CWA 458 1.05 245 5 19 PC2 1.6 120 H400120AC4M CWA 458 1.05 245 5 18 PC2 1.6 120 or 3.90 10 CWA 440 2.22 260 5 23 PC2 1.8 277 or H400TRIAC4M 347 1.92 5 120 or 3.90 10 208 or 2.22 8 CWA 440 245 21 PC2 1.6 H400MLTAC4M 240 or 1.92 5 277 1.68 5 (1) 1000 WATT H36 MERCURY LAMP 480-120 H100048TAC5M CWA 1080 2.28 440 10 19 PC3 2.9 120 or 9.30 20 5.30 15 208 or 21 PC3 2.9 430 H1000MLTAC5M CWA 1080 240 or 4.50 10 277 4.00 10 3 10 MERCURY 400-1000 • 60 Hz • Minimum starting temperature: -30° C • CWA, Normal and High Power Factor models available WATT Capacitor Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 3.2 22.5 240 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a B 3.2 22.5 277 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a C 3.4 3.4 35 240 35 240 1.6 1.8 3.6 3.6 1.91x2.91 1.91x2.91 3.1 3.1 9.5 9.5 n/a n/a n/a n/a C C 3.5 35 240 1.8 3.6 1.91x2.91 3.1 9.5 n/a n/a A 3.4 35 240 1.6 3.6 1.91x2.91 3.1 9.5 n/a n/a C 4.7 24 480 1.8 3.6 1.91x2.91 3.9 19.5 n/a n/a 4.7 24 480 n/a n/a 1.91x2.91 3.9 19.5 n/a n/a C B A B B Capacitors are available as an option for high power factor operation. Also can be used to operate (1) 215 watt S65 High Pressure Sodium lamp. Electrical characteristics will vary from those shown. DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) REFERENCE DRAWING PC2 000 200 500 A B 0.843" 4.250˝ 500K 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes 2.937" 502K 3.875˝ 4.375˝ 4.750˝ 518 4.250˝ 3.875˝ 2.500" 4.375˝ 5.375˝ 5.750˝ 3.125" 3.125" 3.750" 700 WIRING DIAGRAMS S Wiring Diagram 19 Line Cap (Red) Line Wiring Diagram 21 Cap (Red) M L S 0.25” 0.25” 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Com (White) or PERMISSIBLE Com (Yellow) Com (Yellow) or (White) Wiring Diagram 23 240V 208V Cap (Red) 120V INC LAMP W MAX M 5.75” 6.10” 4.60” 277V Com (Yellow) or (White) Com (Yellow) Com (Yellow) Wiring Diagram 24 347V Line 277V Lamp (Blue) Cap (Red) 120V Com Com (White) Com (White) PAGE 5-45 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL 718 Bracket L W 7.75” 1.25” 7.75” 2.75” 5.25” 1.25” 0.656" .218" Dia Thru 4 Holes A B MAX 120V (AUX) BRef. Dwg. PC2 PC3 4 REFERENCE DRAWING 4 0.250 Dia Thru 8 Holes 0.250 Dia Thru 4 Holes A B MAX Wiring Diagram 18 W REFERENCE DRAWING PC3 HID CORE & COIL BALLASTS MERCURY Nom Dimensions Max Open Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Volts Number Type Input Current Voltage Rating Dia Dwg A (1) 400 WATT H33 MERCURY LAMP R-NPF 4.60 10 240 430 240 24 4 1.7 1033-25S 11 2.60 5 R-HPF 3 R-NPF 4.25 10 430 277 24 4 1.7 277 1033-17S 11 2.40 5 R-HPF 3 480-120 H40048TAC4M CWA 458 1.05 245 5 19 PC2 1.6 120 H400120AC4M CWA 458 1.05 245 5 18 PC2 1.6 120 or 3.90 10 CWA 440 2.22 260 5 23 PC2 1.8 277 or H400TRIAC4M 347 1.92 5 120 or 3.90 10 208 or 2.22 8 CWA 440 245 21 PC2 1.6 H400MLTAC4M 240 or 1.92 5 277 1.68 5 (1) 1000 WATT H36 MERCURY LAMP 480-120 H100048TAC5M CWA 1080 2.28 440 10 19 PC3 2.9 120 or 9.30 20 5.30 15 208 or 21 PC3 2.9 430 H1000MLTAC5M CWA 1080 240 or 4.50 10 277 4.00 10 3 10 MERCURY 400-1000 • 60 Hz • Minimum starting temperature: -30° C • CWA, Normal and High Power Factor models available WATT Capacitor Ignitor Oil Filled Oval Ht Total Weight (lbs.) Max UL Catalog Distance Bench Number to lamp (ft) Top Rise B Min Mfd Volt Dry Film Dia Ht 3.2 22.5 240 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a B 3.2 22.5 277 1.5 3.6 1.56x2.69 3.5 6.1 n/a n/a C 3.4 3.4 35 240 35 240 1.6 1.8 3.6 3.6 1.91x2.91 1.91x2.91 3.1 3.1 9.5 9.5 n/a n/a n/a n/a C C 3.5 35 240 1.8 3.6 1.91x2.91 3.1 9.5 n/a n/a A 3.4 35 240 1.6 3.6 1.91x2.91 3.1 9.5 n/a n/a C 4.7 24 480 1.8 3.6 1.91x2.91 3.9 19.5 n/a n/a 4.7 24 480 n/a n/a 1.91x2.91 3.9 19.5 n/a n/a C B A B B Capacitors are available as an option for high power factor operation. Also can be used to operate (1) 215 watt S65 High Pressure Sodium lamp. Electrical characteristics will vary from those shown. DESCRIPTION SUFFIX * For Ballast Only For Bracket Only (see pg. 5-7) For Capacitor Only (see pg. 5-5, 5-6) For Distributor Replacement Kit (see pg. 5-13 thru 5-15) For Canadian Distributor Replacement Kit (see pg. 5-16) For Dry-Capacitor & Ballast (see pg. 5-6) For Bracket & Capacitor (see pg. 5-5, 5-7) For Bracket & Dry-Capacitor (see pg. 5-6, 5-7) REFERENCE DRAWING PC2 000 200 500 A B 0.843" 4.250˝ 500K 0.250 Dia Thru 2 Holes 0.250 Dia Thru 2 Holes 2.937" 502K 3.875˝ 4.375˝ 4.750˝ 518 4.250˝ 3.875˝ 2.500" 4.375˝ 5.375˝ 5.750˝ 3.125" 3.125" 3.750" 700 WIRING DIAGRAMS S Wiring Diagram 19 Line Cap (Red) Line Wiring Diagram 21 Cap (Red) M L S 0.25” 0.25” 0.25” See p. 5-7 for adjustable mounting brackets and detailed bracket drawings. Com (White) or PERMISSIBLE Com (Yellow) Com (Yellow) or (White) Wiring Diagram 23 240V 208V Cap (Red) 120V INC LAMP W MAX M 5.75” 6.10” 4.60” 277V Com (Yellow) or (White) Com (Yellow) Com (Yellow) Wiring Diagram 24 347V Line 277V Lamp (Blue) Cap (Red) 120V Com Com (White) Com (White) PAGE 5-45 FOR MORE INFORMATION CALL 1-800-BALLAST (225-5278) HID CORE & COIL 718 Bracket L W 7.75” 1.25” 7.75” 2.75” 5.25” 1.25” 0.656" .218" Dia Thru 4 Holes A B MAX 120V (AUX) BRef. Dwg. PC2 PC3 4 REFERENCE DRAWING 4 0.250 Dia Thru 8 Holes 0.250 Dia Thru 4 Holes A B MAX Wiring Diagram 18 W REFERENCE DRAWING PC3 547-RS-WS-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (1) fluorescent lamp as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • Low Power Factor Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor FC8T9 1 0.6 30 < .60 .85 2.83 < 10 < 1.7 FC6T9 1 0.64 27 < .60 .90 3.30 < 10 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lag type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: Overall Mounting • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: 6 7/16" 1 7/8" 1 1/2" 6" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) Black White (2) Red (2), Blue (2) • Weight: 10 10 9 2 lbs. Footnotes: * Available in white cans. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Bla ck Line White BALLA ST R ed R ed Blue White Me tal conta cts lam p to fixtu re Ballast must be groun ded. Install in acco rdance with N atio nal Electric Cod e. 1-800-BALLAST www.universalballast.com December 1997 565-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (1) fluorescent lamp as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Trigger Start • High Power Factor (except as noted) Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 1 0.28 30 > .90 .82 2.73 < 32 < 1.7 F15T8 1 0.28 27 > .60 0.87 3.19 < 32 < 1.7 F15T12 1 0.26 29 > .90 0.91 3.18 < 32 < 1.7 F14T12 1 0.25 27 > .90 0.75 2.76 < 32 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) White, Black Red (2), Blue (2) • Weight: 10 10 3.1 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Blue Red BALLAST Red Blue LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 412-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (1) fluorescent lamp as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • High Power Factor (except as noted) Lamp Type # Input Current ( Amps ) F40T12* F40T12ES F40T10 1 1 1 0.48 0.44 0.49 Typical Performance Data Input Power Power Ballast ( Watts ) Factor Factor 57 51 57 > .98 > .90 > .90 Ballast Efficacy Factor T.H.D. % Crest Factor 1.67 1.76 1.68 < 20 < 20 < 20 < 1.7 < 1.7 < 1.7 .95 .90 .95 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI standard C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG ( refer to TechNote # 7b for other wire sizes/lengths ) • For Export Only Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): Black/White White Red (2) Blue/White (2) • Weight: 25 25 37 27 3.1 lbs. Footnotes: * Not for use with "U" lamps. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Black/ White Line Blue/ Whit e White Red Red BALLAST Blue/ Whit e LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 544-L-TC Application and Performance Specifications Description: • Line Voltage: 220 vac, + 5%, - 10%, 50Hz • High Power Factor (except as noted) • Rapid Start Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12 1 0.21 45 < .90 .76 1.71 < 32 < 2.0 F40T12ES 1 0.18 36 > .90 .70 1.95 < 32 < 2.0 F40T10 1 0.22 44 > .90 .72 1.66 < 32 < 2.0 F30T12ES 1 0.17 32 > .60 .70 2.22 > 32 < 2.0 F30T12 1 0.18 36 > .90 .71 1.97 < 20 < 2.0 Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lag type circuit • No PCB's • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Lead Length ( inches, ± 1 ): Black ( refer to TechNote # 7b for other wire sizes/lengths ) White, Blue Red (2) • Weight: 20 35 26 3.2 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Black Red White BALLAST Red Blue LAMP Line Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 458-L-SLH-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (1) fluorescent lamp as indicated below: • Line Voltage: 277 vac, + 5%, - 10%, 60Hz • Rapid Start • High Power Factor Lamp Input Current Input Power Typical Performance Data Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12ES* 1 0.17 44 > .90 .88 2.00 < 20 < 1.85 F40T12 1 0.19 51 > .90 .95 1.86 < 20 < 1.7 F40T10 1 0.19 51 > .90 .90 1.76 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI standard C82.1 • Compatible with PLC and IR systems • Meets U.S. Public Law 100-357 for energy efficiency • Meets CSA Standard 654 for energy efficiency • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): Black/White ( refer to TechNote # 7b for other wire sizes/lengths ) White Red (2) Blue/White (2) • Weight: 25 25 37 27 3.5 lbs. Footnotes: * Not for use with "U" lamps. * This ballast meets low-leakage current to ground requirements. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 36 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Black Line White Red Red Blue/White BALLAST Blue/White LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 502-A-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • Parallel Lamp Operation Lamp • High Power Factor (except as noted) Typical Performance Data Power Ballast Input Current Input Power Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12@100% 2 0.85 94 > .90 .88 0.94 < 20 < 1.7 F40T12 @ 20% 2 0.68 35 < .60 .20 0.57 < 32 < 1.7 F30T12 @ 20% 2 0.58 27 < .60 .21 0.77 < 32 < 1.9 F30T12@100% 2 0.87 83 > .60 .89 1.07 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Lag-Lag type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: Overall Mounting • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG ( refer to TechNote # 7b for other wire sizes/lengths ) • Dimmable to 20% light output • Length: • Width: • Height: • Lead Length ( inches, ± 1 ): Black White Red (2) Blue/ White, Blu Yellow (2) Brown • Weight: 16 3/8" 2 3/8" 1 1/2" 15 25/32" 1 11/16" Footnotes: * Requires two circuit-interrupting lampholders. ** Do not mix 30 & 40 Watt lamps on the same control circuit.Control circuit attached to the brown wire must be sized appropriately. *** See complete warning in catalog. 20 38 26 38 26 20 6.5 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America DIMMER Brown Bla ck W hite Blue /W hite BALLAST Blue Ye llo w Ye llo w Red Red LAMP No. 2 LAMP No. 1 L ine Use d isconn ect lamph old er on ly Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com October 1998 447-LR-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Trigger Start • Series Lamp Operation • Low Power Factor Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 2 0.43 37 > .60 .56 1.51 < 20 < 1.7 F15T8 2 0.5 39 > .60 .75 1.92 < 20 < 1.7 F15T12 2 0.56 42 > .60 .80 1.90 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lag type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: Overall Mounting • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: 6 19/32" 2 3/8" 1 1/2" 6" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) White, Black Red (2), Blue (2) Yellow (2) • Weight: 10 13 18 2.5 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Red Red BALLAST Yellow Blue B lue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 567-L-TC Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 220 vac, + 5%, - 10%, 60Hz • Trigger Start • Series Lamp Operation • High Power Factor (except as noted) Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 2 0.26 53 > .90 .83 1.55 < 20 < 1.7 F15T8 2 0.25 49 > .60 0.86 1.77 < 32 < 1.9 F15T12 2 0.24 47 > .90 0.85 1.81 < 20 < 1.9 F14T12 2 0.22 44 > .90 0.76 1.74 < 20 < 1.9 Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) White, Black Red (2), Blue (2) Yellow (2) • Weight: 10 13 16 3.3 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Red Red BALLAST Yellow Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 554-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 277 vac, + 5%, - 10%, 60Hz • Trigger Start • Series Lamp Operation • High Power Factor Lamp Typical Performance Data Power Ballast Input Current Input Power Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 2 0.22 55 > .95 .86 1.55 < 20 < 1.7 F15T8 2 0.2 51 > .95 .89 1.76 < 20 < 1.9 F15T12 2 0.2 49 > .95 .87 1.78 < 20 < 1.9 F14T12 2 0.17 45 > .95 .79 1.76 < 20 < 1.9 Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, H • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) White, Black Red (2), Blue (2) Footnotes: Yellow (2) • Weight: 10 13 16 3.2 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow BALLAST Yellow Blue Blue Red Red LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 446-LR-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • Series Lamp Operation • High Power Factor Lamp Type F40T12 F40T12ES F40T12/U F40T10 # Input Current ( Amps ) Input Power ( Watts ) 2 2 2 2 0.77 0.66 0.77 0.78 91 75 91 93 Typical Performance Data Power Ballast Factor Factor > .98 > .90 > .98 > .98 .93 .86 .91 .93 Ballast Efficacy Factor T.H.D. % Crest Factor 1.02 1.15 1.00 1.00 < 20 < 20 < 20 < 20 < 1.7 < 1.9 < 1.7 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI standard C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): White, Black ( refer to TechNote # 7b for other wire sizes/lengths ) Red (2), Blue (2) • For Export Only Yellow (2) • Weight: 22 26 36 3.1 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Red Red BALLAST Yellow Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 754-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 220 vac, + 5%, - 10%, 50Hz • Rapid Start • Series Lamp Operation • High Power Factor Lamp Input Current Input Power Typical Performance Data Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12 2 0.43 93 > .98 .94 1.01 < 20 < 1.7 F40T12ES 2 0.37 77 > .90 0.87 1.13 < 32 < 1.9 F40T10 2 0.43 95 > .98 .93 0.98 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Width: • Height: • Maximum Ballast Case Temperature not to exceed 90° C • Lead Length ( inches, ± 1 ): • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG White, Black ( refer to TechNote # 7b for other wire sizes/lengths ) Red (2), Blue (2) Yellow (2) • Weight: Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" 22 26 36 3.5 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow BALLAST Yellow Blue Blue Red Red LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.magnetek.com/ballast December 1997 540-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 220 vac, + 5%, - 10%, 60Hz • Rapid Start • Series Lamp Operation • High Power Factor Lamp Input Current Input Power Typical Performance Data Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12 2 0.42 90 > .98 .91 1.01 < 20 < 1.7 F40T12ES 2 0.36 75 > .90 .86 1.15 < 20 < 1.9 F40T10 2 0.43 94 > .98 .93 0.99 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): White, Black ( refer to TechNote # 7b for other wire sizes/lengths ) Red (2), Blue (2) Yellow (2) • Weight: 20 25 37 3.4 lbs. Footnotes: * For use on 22-volt systems with one grounded conductor Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Red Red BAL LAST Yellow Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 443-L-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 277 vac, + 5%, - 10%, 60Hz • Rapid Start • Series Lamp Operation • High Power Factor Lamp Type F40T12 F40T12ES F40T12ES/U F40T12/U F40T10 # Input Current ( Amps ) 2 2 2 2 2 .36 .32 .32 .36 .37 Typical Performance Data Input Power Power Ballast ( Watts ) Factor Factor 96 82 82 98 101 > .90 > .90 > .90 > .98 > .98 Ballast Efficacy Factor T.H.D. % Crest Factor .97 1.08 1.08 .96 .93 < 20 < 20 < 20 < 20 < 20 < 1.7 < 1.9 < 1.9 < 1.7 < 1.7 .94 .88 .88 .94 .94 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI Standard C82.1 • Compatible with PLC and IR systems • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): White, Black ( refer to TechNote # 7b for other wire sizes/lengths ) Red (2), Blue (2) • For Export Only Yellow (2) • Weight: 20 24 36 3.3 lbs. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line B lack W hite Y ello w Red Red BALLAST Y ello w Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 412-L-SLH-TC-P Application and Performance Specifications Description: Electromagnetic ballasts for (1) fluorescent lamp as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • High Power Factor Lamp Type F40T12ES* F40T12 F40T10 # Input Current ( Amps ) 1 1 1 0.38 0.45 0.45 Typical Performance Data Input Power Power Ballast ( Watts ) Factor Factor 44 52 52 > .90 > .90 > .90 Ballast Efficacy Factor T.H.D. % Crest Factor 2.00 1.83 1.73 < 20 < 20 < 20 < 1.9 < 1.7 < 1.7 .88 .95 .90 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI standard C82.1 • Compatible with PLC and IR systems • Meets U.S. Public Law 100-357 for energy efficiency • Meets CSA Standard 654 for energy efficiency • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" 8 57/64" 1 11/16" • Lead Length ( inches, ± 1 ): Black/White ( refer to TechNote # 7b for other wire sizes/lengths ) White Red (2) Blue/White (2) • Weight: 25 25 37 27 3.4 lbs. Footnotes: * Not for use with "U" lamps. * This ballast meets low-leakage current to ground requirements. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 36 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Black Line Blue White Red BALLAST Blue Red LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 446-L-SLH-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Rapid Start • Series Lamp Operation • High Power Factor Lamp Input Current Typical Performance Data Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F40T12ES 2 0.65 74 > .90 .90 1.22 < 20 < 1.9 F40T12ES/U 2 0.65 74 > .90 .90 1.22 < 20 < 1.9 F40T12/U 2 0.76 90 > .98 .93 1.03 < 20 < 1.7 F40T12 2 0.75 89 > .98 .94 1.06 < 20 < 1.7 F40T10 2 0.76 90 > .98 .95 1.06 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Complies with ANSI standard C82.1 • Compatible with PLC and IR systems • Meets U.S. Public Law 100-357 for energy efficiency • Meets CSA Standard 654 for energy efficiency • Lead type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: • Minimum Starting Temperature: 60° F, 15° C for • Length: • Width: • Height: Energy Savings (34w) lamps; 50° F, 10° C for other lamps • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG Overall Mounting 9 1/2" 2 3/8" 1 1/2" • Lead Length ( inches, ± 1 ): Black White ( refer to TechNote # 7b for other wire sizes/lengths ) Red (2), Blue (2) Yellow (2) • Weight: 8 57/64" 1 11/16" 22 22 26 36 3.4 lbs. Footnotes: * This ballast meets low-leakage current to ground requirements. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 36 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Red Red BALLAST Yellow Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com September 2004 447-LR-VLH-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (2) fluorescent lamps as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Trigger Start • Series Lamp Operation • Low Power Factor Lamp Input Current Typical Performance Data Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 2 0.42 35 > .60 .55 1.57 < 20 < 1.7 F15T8 2 0.53 38 < .60 .76 2.02 < 20 < 1.7 F15T12 2 0.58 40 < .60 .77 1.93 < 10 < 1.7 F14T12 2 0.62 40 < .60 .77 1.95 < 20 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lag type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, H • CSA Certified • Thermally Protected Application: Mechanical: Overall Mounting • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: 6 19/32" 2 3/8" 1 1/2" 6" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) White, Black Red (2), Blue (2) Yellow (2) • Weight: 10 13 18 2.9 lbs. Footnotes: * This ballast meets low-leakage current to ground requirements. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Line Black White Yellow Yellow Red Red BALLAST Blue Blue LAMP LAMP Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997 546-B-TC-P Application and Performance Specifications Description: Electromagnetic ballast for (1) lamp as indicated below: • Line Voltage: 120 vac, + 5%, - 10%, 60Hz • Trigger Start • Low Power Factor Typical Performance Data Lamp Input Current Input Power Power Ballast Ballast Efficacy T.H.D. Crest Type # ( Amps ) ( Watts ) Factor Factor Factor % Factor F20T12 1 0.58 29 < .60 .82 2.83 < 10 < 1.7 F15T8 1 0.55 25 < .60 .89 3.50 < 10 < 1.7 F15T12 1 0.61 30 < .60 .96 3.23 < 10 < 1.7 F14T12 1 0.66 30 < .60 .86 2.87 < 10 < 1.7 Application and Performance Specification Information Subject to Change without Notification. Performance: Safety: • Designed in accordance with ANSI C82.1 • Compatible with PLC and IR systems • Lag type circuit • No PCB's • UL listed (Class P, Indoor and Type 1 Outdoor, HL) • CSA Certified • Thermally Protected Application: Mechanical: Overall Mounting • Minimum Starting Temperature: 50° F, 10° C • Maximum Ballast Case Temperature not to exceed 90° C • Sound Rated: A • Remote Mounting: 20 feet with minimum 18 AWG • Length: • Width: • Height: 6 7/16" 1 7/8" 1 1/2" 6" • Lead Length ( inches, ± 1 ): ( refer to TechNote # 7b for other wire sizes/lengths ) Black White, Blue Red (2) • Weight: 10 17 12 1.9 lbs. Footnotes: * Requires one circuit-interrupting lampholder. Warranty: Universal Lighting Technologies warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 24 months from date of manufacture when properly installed and under normal conditions of use. Call 1-800-BALLASTx800 for technical assistance. Manufactured in North America Black White BALLAST Blue R ed R ed LAMP U se disconne ct Line lam phold er o nly Ballast must be grounded. Install in accordance with National Electric Code. 1-800-BALLAST www.universalballast.com December 1997