SENTROL
ShatterPro™ Residential Advanced Acoustic Sensor
with Pattern Recognition Technology™
Protected under U.S. Patent 5,192,931 and 5,510,767
Installation Instructions for Surface Mount Models
Surface Mount ShatterPro™ Residential SPRES
Surface Mount ShatterPro™ II
Residential SPRES-EZ
WIRING
Strip back the outer jacket on your wiring cable. This will allow wires to flex in the case. Make sure the cable is slack in the wall to
avoid stressing the wires at their connections.
–
+
N.C.
COM
SPRES/SPRES-EZ
ORDERING INFORMATION
Description
Model No.
Color
ShatterPro™ Residential EZ, non-latch LED
SPRES-EZ
White
SPRES
White
5709C-W
White
ShatterPro™ Residential, non-latch LED
Hand-held Tester, for testing effective range
RANGE OF COVERAGE
25' (7.5 m)
25'
(7.5
m)
ShatterPro sensors are omni-directional, providing 360° coverage.
Coverage is measured from the sensor to the point on the glass
farthest from the sensor. The sensor can be mounted as close as
3.3' (1 m) from the glass.
1. Mounted on opposite wall or adjoining walls, range is 25 ft.
(7.5m) for plate, tempered, laminated and wired glass.
2. Mounted on the ceiling, maximum range is 25 ft. (7.5m) for
plate, tempered, laminated and wired glass.
3. For armor-coated glass, mount sensor no more than 12 ft.
(3.65m) from glass.
Recommended Glass Size:
Minimum 1' x 2' (0.3 m x 0.6 m) or larger
Glass thickness:
Plate: 3/32" to 1/4" (2.4 mm to 6.4 mm)
Tempered: 1/8" to 1/4" (3.2 mm to 6.4 mm)
Wired: 1/4" (6.4 mm)
Laminated: 1/8" to 1/4" (3.2 mm to 6.4 mm)
TESTING THE SENSOR
Put Sensor in Test Mode
1. Connect 9-volt battery to sensor for pre-testing.
2. Use double-stick tape provided to temporarily mount sensor
in desired location.
3. Use Sentrol 5709C Hand-Held Tester to put sensor into test
mode. Set tester to “tempered glass” and hold on top of
sensor. Activate tester — this will trip sensor into test mode
for one minute. In test mode, LED will blink continuously.
To extend test time, activate tester at least once a minute.
Test the Sensor (sensor must be in test mode, blinking)
1. The 5709C tester has settings for different types of glass.
Use “tempered” setting if unsure of glass type.
2. Hold tester near surface of glass to be protected and aim at
sensor. Press test button.
If drapes or blinds are present, hold the tester behind the
closed drapes or blinds.
3. If LED stays on for 4 seconds, glass is within detection range
of sensor.
4. If LED does not stay on, reposition the sensor and retest.
(Verify adequate battery strength in tester.)
gle
• Sin
• Co
ntin
uou
s
P
Temlate •
p
Lamered •
Ba
inate
Battttery
d•
ery LED
stay is OK
s on if L
duri ED
ng te
st
Sha 570
tter 9C
Seri
Use es Tes
ter
for
Shatestin
ShttaerProg:
Shatterbo
Shatterboxx
tterS II
witc
h
SEN
TRO
L
For Best Detection, Avoid Installing In:
• Rooms with lined, insulating, or sound deadening drapes.
• Rooms with closed wooden window shutters inside.
Hold tester so that the speaker is
within 1 inch of sensor microphone
In test mode the sensor LED will light
solid for about 4 seconds,
then blink for about a minute
<1 inch
How Test Mode Works:
Test Mode is activated by the hand-held tester when the tester is
held directly over the microphone and set off. The sensor’s LED
will blink continuously for 1 minute. During this time, the
installer can test the unit using the instructions above. When the
system is armed and the ShatterPro trips to an alarm condition,
the LED will latch solid for 4 seconds and then revert back to a
1- minute test mode. At the end of 1 minute, the LED will
extinguish.
MOUNTING
Locate sensor at least 4' from noise sources (TVs, speakers, sinks, Ceiling Mounting
doors, etc.), and at least 3.3' away from nearest point of glass to
Mount the sensor in any type of ceiling in a location which is in
be protected.
direct line of sight of the windows to be protected. However, since
Sensor location should be in direct line of sight of glass to be
sound travels directionally out from the broken window, a position
protected. Glassbreak sensors cannot reliably detect breaking
8' (2.4 m) into the room provides better detection (see figure).
glass around corners or in other rooms.
Wall Mounting
The best location for mounting the sensor is on the opposite wall
— assuming the glass to be protected is within the sensor’s range
and line of sight (see figure). The ceiling and adjoining (side)
walls are also good sensor locations.
Pre-Wire Installation for the SPRES-EZ
1. Place the SPRES-EZ trim plate accessory over the single gang
box.
2. Route wire through wire entry hole.
3. Mount the sensor to the single gang box using the screw holes
that align to the gang box.
4. Attach wires to terminal strip and snap front cover in place.
AVOIDING FALSE ALARMS
Don’t use where white noise, such as air compressor noise,
is present. (A blast of compressed air may cause a false
alarm.)
•
Avoid rooms smaller than 10' x 10' (3 m x 3 m) and rooms
with multiple noise sources such as kitchens, glass booths,
noisy areas, garages, bathrooms, etc.
•
In rooms less than 10' x 10', use a reduced-range ShatterPro™
Residential or a ShatterPoint (model 5600, 5620).
Proper Testing
The ShatterPro Residential is designed to detect the breaking
of framed glass mounted in an outside wall. Testing the sensor
with unframed glass, broken bottles, etc., may not trip the
sensor. The ShatterPro Residential typically does not trip to
glass breaking in the middle of the room. No burglar breaks
glass in the middle of a room, so such breaks are false alarms.
'
•
D
25
For Best False Alarm Immunity:
• Avoid 24-hour loop applications (perimeter loop OK).
D
Optimum
Detection
Zone
'≤
Do Not Install In Humid Rooms
No glassbreak sensor is hermetically sealed. Excess moisture
on the circuit board can eventually cause a short and a false
alarm.
D
D
Areas to Avoid:
• Glass airlocks and glass vestibule areas
• Kitchens
• Corner mounting
• Residential car garages
• Small utility rooms
• Stairwells
• Bathrooms
• Other small acoustically live rooms
For glassbreak protection in such applications, use Sentrol
shock or ShatterPoint sensors on the windows or window
frames.
is distance from glass.
The optimum performance zone
is distance D in either direction
on the glass.
ShatterPro
Mounting location can affect the ShatterPro’s detection ability.
To ensure optimum performance, the ShatterPro’s coverage
zone width should be no greater than two times the distance
from the sensor to the closest point of glass. For instance, if
the ShatterPro is mounted 10 feet from the glass, its optimum
performance zone will be 10 feet in either direction of the
“mid-point” (see illustration above). ShatterPro can be
mounted from 3.3' to 25' from the farthest point on the glass.
Avoid 24-Hour Loop Applications
The ShatterPro Residential is recommended for perimeter loops and is
designed to function in occupied areas. In 24-hour loop applications,
where the sensor is armed all day and all night, the false alarm
technology will be pushed to its limit. Some sounds can duplicate the
points on the glassbreak pattern the ShatterPro Residential detects.
Install the ShatterPro Residential on a perimeter loop which is
armed whenever the door and window contacts are armed.
Protecting Occupied Areas
The ShatterPro's false alarm immunity is best in rooms with only
moderate noise. For 24-hour occupied area protection, use Sentrol
shock sensors or the ShatterPro™ Plus 5885 or ShatterPoint (5600,
5620).
NOTE: ShatterPro Residential may not consistently detect cracks
in glass, or bullets which break through the glass. Glassbreak
sensors should always be complemented with interior protection.
Connection to Panel
The ShatterPro Residential should be connected to a UL Listed
control panel, or a power supply that provides at least four hours of
standby power.
SPECIFICATIONS
Electrical
Voltage ...................................................................... 9 to 16 VDC
Current ............................................... 12 mA typical, 25 mA max.
Relay output ............ Normally closed, open 4 seconds upon alarm
On resistance ................................................ 10 Ohm – 5 +10
Off resistance ....................................................... > 1 MOhms
Maximum loop rating (relay or tamper loop) .........................
...................................................................... 16 VDC, 50 mA
Wiring terminals .........................................................22-18 AWG
Environmental
Lightning suppression .......................... 400 watts for 1 msec pulse
RF Immunity .............................. 20V/m min from 1MHz to 1GHz
Microphone ............................................ Omni-directional electret
Operating Temperature ............. 0° F to 120° F (-18° C to +50° C)
Humidity ............................................10% to 90% noncondensing
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment on and off, the user is
encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
Under FCC Rules, Part 15 for Class B digital devices, operation is
subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
G-3514-798
15422 Rev. B
Download