HDMI Test Solutions (QPHY-HDMI2) Datasheet

HDMI Test Solutions
QPHY-HDMI2
Key Features
• Compliant with Version 2.0 and
Version 1.4b HDMI Compliance
Test Specification
• Simple and easy-to-use
automated testing
• Dedicated signal pull-up
termination provided by
TF-HDMI-3.3V enables full
bandwidth testing using cables
• Support for optional RF switch
matrix to further reduce test time
and complexity
• Powerful and flexible analysis
The QPHY-HDMI2 software package
test equipment platform provides a
for the WaveMaster/SDA 8 Zi series
complete set of amplitude and jitter
of oscilloscopes provides a concise
measurements as defined in the
set of validation/verification and
HDMI specification. This combination
debug tools written in accordance
of measurements makes
with version 2.0 of the High Definition
QPHY-HDMI2 a cost-effective,
Multimedia Interface (HDMI)
compelling HDMI solution.
electrical test specification. HDMI
Once a problem is detected, all
test modes cover amplitude, timing,
and jitter parameters. In addition
to standard eye pattern and jitter
tests for HDMI 2.0, the SDA real-time
of Teledyne LeCroy’s powerful serial
data analysis tools are at your
disposal to help find the root cause.
tools offer unmatched insight
for diagnosing and solving
elusive problems
• Support for all clock rates
described in Version 2.0 of the
specification
• Connection diagrams help to make
sure that you get the right setup
on the first try
• QualiPHY report generation
creates comprehensive reports
with all pertinent test information
QPHY-HDMI2 provides a highly
automated and easy-to-use
solution for HDMI transmitter
testing in accordance with
Version 2.0 of the HDMI
Compliance Test Specification.
QPHY-HDMI2 Makes Compliance Testing Easy
Often, compliance testing is a very difficult task.
The user must make the necessary connections
between the oscilloscope and the device under test,
manually configure the oscilloscope for the appropriate
measurement, perform the test procedure as specified
by the test specification, record the results, and finally
compare the results to the appropriate limit in the
compliance specification. QPHY-HDMI2 does many of
these steps for you automatically.
Comprehensive test automation – QPHY-HDMI2 configures the
oscilloscope to perform tests in an optimum fashion. Here, rise and
fall times are quickly and automatically measured on a very large
number of edges to ensure compliance.
Optional RF Switch Matrix Support
HDMI 2.0 compliance testing requires testing of four
differential signals in both single-ended and differential
configurations. By its nature, this kind of testing means
moving and reconnecting cables between the device under
test and the oscilloscope. QPHY-HDMI2 supports this
type of “manual” operation, and walks the user through it
in the most efficient way possible. But for those who wish
to further shorten test times, increase automation, and
remove complexity, QPHY-HDMI2 also includes the ability to
automatically change connection configurations using an
RF switch matrix.
Simplify testing – QPHY-HDMI2 can control a switch matrix,
enabling fully-automated testing with no switching of cables.
Fixture and Switch De-embedding
As HDMI signal rates increase to 6 Gb/s, the effects of
test interconnects on the signals under test become more
critical. In some cases, there is the possibility that an
otherwise passing device may fail due to these effects.
QPHY-HDMI2 includes the ability to de-embed fixtures
and RF switches using Teledyne LeCroy’s Eye Doctor II
advanced signal integrity toolkit, enabling testing of the
DUT’s true performance margins.
Simple de-embedding – The ability to de-embed fixtures and cables
ensures that the best margins possible can be maintained on tests
such as eye diagrams.
2
Supported Tests from the HDMI Version 2.0
Compliance Test Specification
• HF1-1 Source TMDS Electrical – VL and Vswing
• HF1-2 Source TMDS Electrical – TRISE, TFALL
• HF1-3 Source TMDS Electrical – Inter-pair Skew
• HF1-4 Source TMDS Electrical – Intra-Pair Skew
• HF1-5 Source TMDS Electrical – Differential Voltage
• HF1-6 Source TMDS Electrical – Clock Duty Cycle and
Clock Rate
• HF1-7 Source TMDS Electrical – Clock Jitter
• HF1-8 Source TMDS Electrical – Data Eye Diagram
Compliance Reports contain all of the tested values, the specific
test limits, and screen captures. Compliance Reports can be
created as HTML, PDF, or XML files.
Eye Test Connection Diagrams prompt the user
to make the necessary connections.
QualiPHY
QualiPHY is designed to reduce the time, effort and
specialized knowledge needed to perform compliance
testing on high-speed serial buses.
• Guides the user through each test setup
• Performs each measurement in accordance with
the relevant test procedure
• Compares each measured value with the applicable
specification limits
• Fully documents all results
• QualiPHY helps the user perform testing
the right way—every time!
QualiPHY has many preset compliance configurations but also
enables users to create their own configuration and limit sets.
3
ORDERING INFORMATION
Product Description
Product Code
QualiPHY Enabled HDMI 2.0 test option
*QPHY-HDMI2
Upgrade from QPHY-HDMI
RK-QPHY-HDMI-QPHY-HDMI2
HDMI Pull-up Terminator — for use with the
TF-HDMI-3.3V
WilderTech HDMI2-TPA-P test fixture
HDMI Pull-up Terminator Quad Pack
TF-HDMI-3.3V-QUADPAK
— for use with the WilderTech
HDMI2-TPA-P test fixture
* TF-HDMI-3.3V-QUADPAK required.
Recommended Oscilloscopes
13, 16, 25, 30 GHz, 40/80 GS/s, 4 Ch,
32 Mpts/Ch WaveMaster with 15.3” WXGA
Color Display. 50 Ω and 1 M Ω Input
WaveMaster 8Zi-B oscilloscopes and WaveMaster/SDA 8Zi-A
oscilloscopes are also supported, but a 6.5 Gb/s serial trigger
(included as standard on SDA 8Zi-B oscilloscopes) is required for
HDMI 2.0 testing. Contact Teledyne LeCroy for more information.
TF -HDMI-3.3V adapter provides the necessary 3.3 V pull-up
termination for HDMI 2.0 testing.
TF-HDMI-3.3V
System Requirements
The TF-HDMI-3.3V adapter provides the necessary 3.3 V
pull-up termination for HDMI testing. The TF-HDMI-3.3V
provides both a signal path through to the oscilloscope with
a 3.3 V pull-up termination as well as an input that
is directly terminated to 3.3 V. This is required for
terminating the data lines that are not currently under
test. The TF-HDMI-3.3V-QUADPAK provides four adapters
and eight SMA-SMA cables to allow for the testing of all
HDMI signals (Clock, D0, D1 and D2).
SDA 813Zi-B
816Zi-B, 820Zi-B
825Zi-B, 830Zi-B
SDA 8 Zi series oscilloscope:
– 8 GHz BW minimum for HDMI 1.4b tests
– 13 GHz BW minimum for HDMI 2.0 tests
SDAIII Serial Data Analysis package:
– (single-lane version or higher)
VirtuaProbe De-embedding and Emulation Toolkit
– Required for worst-case cable emulation,
equalizer emulation, and optional fixture and
switch de-embedding
Recommended HDMI 2.0 Test Fixture:
– Wilder Technologies HDMI2-TPA-P
Other accessories
Recommended for customers without direct DUT control:
Granite River Labs HDMI-CONT EDID controller
Required for automatic signal switching:
Qty 2 – Mini-Circuits RC-8SPDT-A18 Relay Bank
Qty 1 – HDMI termination module
(e.g. Wilder Technologies HDMI-TPA-T)
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties,
our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:
No charge for return shipping
Long-term 7-year support
Upgrade to latest software at no charge
•
•
•
1-800-5-LeCroy
teledynelecroy.com
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
© 2016 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
qphy-hdmi-2.0-ds-23sep16