SOLID STATE SECURITIES, INC. SOLID S T SS S ATE ECURITIES, RESE SS90 T INC SOLID STATE FAIL-SAFE LISTED U * PATENT UNIT L 99Y9 PENDING RELEASING DEVICE "SS90" SERIES CONTROLS Electronic Control & Protection Specialists P.O. BOX 2520 • HAZLETON, PA 18201 570-454-7982 • 570-455-7361 fax http://www.sssiusa.com E-mail - ss90@sssiusa.com MADE IN THE U.S.A. MODEL SS90-MGO: SOLID STATE GATE OPERATOR CONTROL BOARD S/N____________________ GENERAL DESCRIPTION: The Solid State Securities “SS90" Model MGO gate operator circuit board is a 100% solid state control designed for use on both slide and swing gate operators utilizing a 110VAC, 3 wire motor configuration. The SS90-MGO will interact with a wide variety of external controls, including safety hardware and detection devices to create a comprehensive gate system. The SS90-MGO, unlike most similar controls offering more optional features than those which are standard, incorporates most industry desired control functions as basic features. Standard performance features include, a) single button, three button and radio receiver control interfaces, b) both normally open and normally closed safety loops, a one pass anti-tail gate loop as well as a phantom loop function, c) integral A.E.C obstruction sensing technology (Anti-Entrapment Circuitry) with separate sensitivity adjustments to accommodate differing directional motor loads (i.e.: sloped installations, etc.), d) separate adjustable timers for maximum run times and auto close functions, and e) dip switch selectability of most features PLUS switch selection for motor rotation/limit switching eliminating the need to rewire for left hand/right hand installations. In addition to the unmatched standard features of the SS90-MGO, factory options include a Dual Motor model, standard warning device outputs, bilingual voice warning modules and a battery backup feature connector for use with the SS90-GBS, a D.C. gate backup system. Verify use of control for compliance with all applicable installation standards as well as local codes established by the authority having final jurisdiction. To be installed by factory authorized technicians only. CAUTION: Review all installation instructions, procedures, cautions and warnings provided by gate manufacturer relative to proper operation of this control with specific operator, as well as all warnings contained within this manual prior to installing and/or servicing this product. TEST ALL SYSTEM FUNCTIONS REGULARLY TO ASSURE PROPER OPERATION. Installation and testing to factory specifications shall be performed by factory authorized personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), local, state, county, district and/or other applicable building and fire standards, guidelines, regulations and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). TECHNICAL SUPPORT (570) 455-0577 HAZLETON, PENNA 18201 © 1998 SSSI, PATENTS PENDING ALL RIGHTS RESERVED P/N:MGRV1-698 1 FIGURE 1 SS90-MGO Wiring connections, potentiometer adjustments, switch and jumper selects. See Figure 2 for additional information. * See footnotes **SWJ Rotation Select TBD Battery Option ON OFF *SW1 - Feature Select 1 TBG Factory Use Only 2 Open Limit LED ON OFF Close Limit LED 6 - Open-Close-Open 5 - Timer Close 4 - One Pass 3 - Safety Loop 2 - Radio Receiver 1 - Lock P3 - Close Timer CW-Min. CCW-Max ~ 90 sec) ~ 0 sec) ( ~ (~ Limit Switches: Open Limit N/C Common Common Close Limit N/C Motor 1 CCW Motor Rotation Close TBF 2 CW Open Motor Rotation 3 Common (Black wire) P4 - Max Run Timer CW-Min. CCW-Max ~ 90 sec) ~ 15 sec) ( ~ (~ ! 1 2 3 4 Adjust and test A.E.C. carefully to reduce possibility of serious injury. Utilize wired safety device as primary detection device when possible. CCW-Max P2 - Open A.E.C. CW-MIN Lock DC Power TBC CCW-Max P1- Close A.E.C. CW-Min Phantom Loop Safety Loop J11 F1 -24vac In 1Amp 1 2 3 4 1 2 3 TBE TBH 1 2 TBB 24Vac Out J9 3 4 { Radio Rcvr { Master/ Slave Open F2 - 120vac In Close 10 Amp Stop Serial Number 12 - Phantom loop Common 11 - Phantom loop normally open 10 - Safety loop common 9 - Safety loop normally closed 8 - Safety loop normally open 7 - Normally Open Single button 6 - Normally Open Single button 5 - Push button common 4 - Open push button 3 - Close push button 2 - Normally Closed Stop switch 1 - Normally Closed Stop switch TBB 24Vac In SW1 FEATURE SELECT SW 1 ON for a 110 VAC Lock in Close Limit SW 2 ON for single button and/or Radio Receiver SW 3 ON for safety loop (SW 4 must be OFF) SW 4 ON for 1 pass (SW 3 must be OFF) SW 5 ON for Close timer (SW 4 should be OFF) SW 6 ON Open overrides Close until Limit or Stop OFF Open DOES NOT override CLOSE 1 2 3 TBA 110 VAC IN 1- LINE 2- NEUTRAL 3- LOCK OPTION Motor Rotation/Limit Selection SWJ1 (ON) / SWJ2 (OFF) - Open CW Rotation SWJ1 (OFF) / SWJ2 (ON) - Open CCW Rotation **NOTE: The Switches (SWJ1 & SWJ2) should not be both ON or OFF! JUMPER SELECT J 9 ON J 11 ON Provides 24 VAC OUT on TBB Positions 1 & 2 In accordance with SW 2 OFF Provides Radio Receiver "Open Only" function allowing Close Timer to close. POTENTIOMETER ADJUSTMENTS P 1 (CLOSE)Anti Entrapment Circuit Adjust - Clockwise (CW) will provide obstruction reversing feature with minimum obstruction torque (max sensitivity) P 2 (OPEN)Anti Entrapment Circuit Adjust -Clockwise (CW) will provide obstruction stop feature with minimum obstruction torque (max sensitivity) P 3 (MAX RUN)Adjusts Maximum run time (counter Clockwise to increase) P 4 (CLOSE TIMER) Adjust Delay for Close Timer (counter clockwise to increase) 2 FIGURE 2 Typical system wiring - SS90-MGO Gate Operator Board. Refer to operator manufacturer instructions for wiring applicable to specific operator. Configuration may differ. (See Figure 1 for Feature switches, jumper selects and potentiometer adjustments) SS90-MGO Slave if applicable SS90-MGO Master (1) C N/O (1) (7) Open Limit (7) (3) N/O (2) (1) Close Limit (1) C (5) (1) N C W C C W * (6) * (6) Optional Phantom Loop 12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1 (4) 1 2 3 4 Normally Closed Normally Open Optional Single Button Open Close Stop 1 2 3 (1) (1) 110 VAC (1) (1) Slave connections same as master (2) Close timer set on master unit, slave timer off (3) SW1-6 must be same on both master & slave All other switces off. Lock optional (4) Use on Master/Slave only (5) Set run timers approx. same adjustment (6) A.E.C's adjusted separatedly on both Master & Slave (7) Select rotation separately on Master & Slave 1 2 3 Radio Receiver 24VAC to MGO transformer 3 Line * Adjust and test A.E.C. carefully to reduce ! possibility of serious injury. Utilize wired safety device as primary detection device when possible. Ground Technical Support 570-455-0577 8:00a.m. - 5:00p.m. EST } Safety Loop NOTES/TEST RECORDS Copy this sheet and attach to manual for additional test data as required. Maintain test records in secure location for future reference. Serial Number ____________________ TEST DATE PERFORMED BY WITNESSED BY 4 COMMENTS