INSTALLATION INSTRUCTION MHT-CL/RCL 1. Main Data For RCL Fixture Model Lamp Type RCL-40E RCL-55E MHT-ST-40-U Power Factor (COSφ) 0.95 Net Weight (lbs) 8.0 0.49~0.21 MHT-ST-55-U 0.95 8.0 74 0.61~0.27 MHT-ST-70-U 0.95 8.4 84 0.70~0.30 MHT-ST-80-U 0.95 8.4 Input Wattage (W) Current (A) Ballast Model RT40W 42 0.35~0.15 58 RCL-70E RT55W 110V ~ 277V RT70W AC 50/60Hz RCL-80E RT80W 2. Power Supply (VAC) Circuit Diagram: Without Photocell With Photocell (Button Type) 3. Brown L Black White N Green E L N White E Green Induction lamp Red Red Black Brown Ballast Lamp Red Outline and Dimensions: (mm) ※ Installation: Standard Surface Mount & 3/4” Pendant. Optional 1/2” Pendant with adapter. Phone # (718) 524-4370 Fax # (718) 524-4390 www.MHTLIGHTING.com INSTALLATION INSTRUCTION 4. MHT-CL/RCL Installation and Maintenance Instruction: 4.1 The efficient and reliable grounding is a must not only for the personal protection, but also for the proper use of electronic ballast to meet the national standard of EMC without interference to other equipments. 4.2 The Luminaire shall be installed in the area with good ventilation, no corrosive gas and no combustible and explosive objects. 4.3 The supply voltage is allowed to be varied at 110V-277V. It will influence the normal start and operation of lamp and damage the electronic ballast if it is outside of this range. 4.4 The maintenance can only be done after the power is cut off and the lamp is cold down to prevent scald and electric shock accident. 4.5 Do not remove the lamp when power on. 4.6 The product shall be installed and serviced by the competent and certified electrician. Note:1. The cover shall be replaced when it is cracked . 2. The above data is subject to change without notice Warning: The efficient and reliable ground is a must when install Luminaire, to prevent electric leakage and electric shock accident. End user should be responsible for the consequence if against the instruction. Phone # (718) 524-4370 Fax # (718) 524-4390 www.MHTLIGHTING.com INSTALLATION INSTRUCTION MHT-CL/RCL 1. Main Data For CL Fixture Model Lamp Type MHT-CL-40E RT40W MHT-CL-55E RT55W MHT-CL-70E RT70W MHT-CL-80E RT80W Supply Voltage (VAC) 120V~277V AC (-10%~+10%) 50/60Hz MHT-CL-100E RT100W Power Input Working Net Wattage Current Ballast Model Factor Weight (W) (A) (COSφ) (lbs) 42 8.7 0.35~0.15 MHTST-40-U 58 0.49~0.21 MHTST-55-U 8.7 74 0.61~0.27 MHTST-70-U ≥0.95 9.4 84 0.70~0.30 MHTST-80-U 9.8 105 0.88~0.38 MHTST-100 10.0 2. Circuit Diagram Without Photocell With Photocell (DTL Button Type) Brown L Black Electronic White N Green ballast E Red 绿 L N White E Green Red Lamp Black Brown Ballast Lamp Red 3. Outline Dimensions (inch/mm) Mounting: Surface Ceiling/Pendant/Hook Min distance of 0.8m (2.62ft) should be maintained between the fixture and the objects 4. Installation and Maintenance Instruction 4.1 The efficient grounding is a must, not only for the personal protection, but also for the proper use of electronic ballast to meet the national standard of EMC without interference to the equipment. 4.2 The Luminaire should be installed in an area with good ventilation, with no corrosive gas and no combustible or explosive objects. 4.3 The supply voltage is allowed to be varied at +10% to -10%. It will influence the normal start and operation of lamp and damage the electronic ballast if it is outside of this range. 4.4 The maintenance can be done only after the power is cut off and the lamp is has cooled down. 4.5 The product is to be installed and serviced by a competent and certified electrician. 4.6 The wiring inside the Luminaire is tool-free and it is not allowed to disconnect with the lamp while the power is on. 4.7 The ambient temperature is allowed to be -20°F to +120°F 4.8 Operation while the glass cover is open is forbidden. Phone # (718) 524-4370 Fax # (718) 524-4390 www.MHTLIGHTING.com INSTALLATION INSTRUCTION MHT-CL/RCL Note: The above data is subject to change without notice. ! Warning: The Luminaire shall be grounded reliably to avoid accidental power leakage and electric shock. Installation: Loosen two screws on Ballast Enclosure (Top Cover) Fig.1 Loose two screws on Cover Disconnect Quick Connectors Fig.2 Disconnect connectors Seal Connector Ballast Enclosure (Top Cover) Fig.3 Separate the lamp compartment and the ballast enclosure Anchoring screw for ceiling Concave plot Fig.4 Drill small holes on the concave plot Fig.7 Put the power cord through the Seal Connector and make connection to Terminal Block Phone # (718) 524-4370 Fig. 5 Knock out the ½” knockout and fasten the Seal Connector Fig.8 Slide in Lamp Compartment back to Ballast Enclosure and reconnect Quick Connectors Fax # (718) 524-4390 Fig. 6 Secure the Enclosure to the ceiling Ballast Fig.9 Secure Ballast Enclosure with the screws www.MHTLIGHTING.com