fire stop products

advertisement
FIRE STOP PRODUCTS
Thermal
Thermal
ER
ATE D
2hr
FI R
FI R
Thermal
Thermal
P r o t e c t i n g
ER
ATE D
2hr
b u i l d i n g s ,
4hr
4hr
p e o p l e
a n d
t h e
FI R
FI R
Fire I Thermal I Acoustic I Airtightness I
ER
ER
ATE D
2hr
ATE D
2hr4hr
e n v i r o n m e n t
4hr
Contents
www.pfc-corofil.com
Cavity Barriers
C144 AFT Cavity Closer
C450 Cavity Firestop
C470 Raised Floor Firestop
Rainscreen Fire Barrier System
Ventilated Fire Barrier
Linear Gap Seals
C144 Cavity Firestop Strips & Blocks
C500 Intumescent Expansion Joint
C500X Intumescent Movement Joint
Intumescent Firestrip Tape
Acoustic Profile Fillers
Sealants
Acoustic Intumescent Sealant
Fire Resistant Silicone Sealant
High Expansion Intumescent Sealant
LUL Intumescent Sealant
Service Penetrations
Coated Panel System
Ablative Coating
C25 Cable Firestop
Retro-Fit Cable Transits
Intumescent Pillows
Firestop Compound
Contents
www.pfc-corofil.com
Service Penetrations cont.
Intumescent Silicone Putty
Intumescent Conduit
Glass Cloth Luminaire Canopies
Thermal Recessed Luminaire Covers
Intumescent Vent Duct Sleeves
Intumescent Fan & Vent Sleeves
Cable Basket Fire Sleeves
Pipework
Firestop Collars
Intumescent Pipe Wraps
Cast-In Device
Insulated Fire Sleeves
Metal Case Fire Sleeves
Electrical
Intumescent Putty Pads
Fire & Acoustic Switch Box Inserts
Intumescent Downlight Covers
Thermal Loft Covers
CAVITY BARRIERS
PFC Corofil C144 AFT Cavity Closer
Application
Description
PFC Corofil C144 AFT Cavity Closer is used to close
PFC Corofil C144 AFT Cavity Closers are produced
off masonry wall cavities, providing a robust acoustic,
from a high density mineral wool bonded to a
fire and thermal seal.
Tested in accordance with
Polythene DPC. The product is supplied in 1 metre
BS 476:Part 20:1987, PFC Corofil C144 AFT Cavity
lengths and is manufactured to suit the cavity to be
Closers provide up to 4 hours fire protection.
filled. The DPC layer is oversized in its width and
length compared to the mineral wool section to
C144 AFT Cavity Closers reduce cold bridging in
FIRE RATINGS
Tested to BS 476:Part 20:1987
0
2hr
4hr
provide an essential overlap zone.
Fire Rating
cavities around windows and doors, accommodate
movement in the building and take up small
Installation
tolerances within the brick / block cavity. They also
PFC Corofil C144 AFT Cavity Closers can easily be
make a significant contribution to the thermal
fitted as the brick and block work is installed. The
insulation of properties helping reduce energy costs
closer must be fitted with the DPC against the inner
You can request from our technical
and carbon emissions.
face of the outer leaf of the cavity wall. Adjacent
sales office the following information:
TECHNICAL INFORMATION
lengths of material must have the mineral wool joints

Complies with Building Regulations Approved
tightly abutted, ensuring that the DPC is fully lapped
 Material Safety Data Sheets
Document E (2003)
by 100mm at its base. The top of vertical C144 AFT
 Installation Instructions
Complies with Building Regulations Approved
Cavity Closers should be sealed by a cavity tray or to
Document L
the underside of the lintel party walls, reducing room-

Polythene DPC conforms to BS 6515 (1984)
to-room noise transfer.

Simple installation

Sizes
1 metre lengths of C144 Firestop Strip are bonded to
Fire Rating
Fire Rating
1100mm long x 150mm wide (1-2 hours) or 250mm
Minimum Depth of
wide (4 hours) Polythene DPC.
C144 AFT Cavity Closer
ORDERING
When ordering this product you will
need the following information:
 Size of cavity
 Fire rating
 Quantity required (in linear meters)
1 Hour
80mm
The C144 Firestop Strip thickness is oversized by
2 Hours
100mm
5mm to be fitted into the cavity under compression.
4 Hours
175mm
Please order from our technical
The depth of the seal is dependant on the fire rating
sales office.
required (see fire rating). Standard cavity widths
Acoustic
PFC Corofil C144 AFT Cavity Closers have been
include 50mm, 75mm, 100mm, 125mm and 150mm.
PFC Corofil
Non standard sizes on request.
Units 3-4
King George Trading Estate
acoustically assessed in a number of cavity sizes.
Please consult our technical sales office for further
Specification
details.
Install PFC Corofil C144 AFT Cavity Closers in all
masonry wall cavities to provide 1, 2 and 4 hour fire
Thermal Performance
The thermal conductivity of C144 mineral wool is
0.035 W/Mk
rated seals.
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
CAVITY BARRIERS
PFC Corofil C450 Cavity Firestop
Application
Description
PFC Corofil C450 Cavity Firestops provide firestopping
PFC Corofil C450 Cavity Firestops are manufactured from
between
a high density, low phenolic binder content, mineral fibre.
the
edge
walling/cladding
of
system
a
or
floor
slab
within
a
and
curtain
wall
The material is supplied in one metre lengths to suit the
construction. Tested in accordance with BS 476:Part 20,
cavity
size of the cavity to be filled. The depth of the product is
PFC Corofil C450 Cavity Firestops give provide up to 2
dependent on the fire rating required (see fire rating
hours fire protection in cavities fitted horizontally and
table). The thickness is supplied oversized for fitting under
vertically. They also make a significant contribution to the
slight compression.
reduction of air leakage in properties helping reduce
FIRE RATINGS
Tested to BS 476:Part 20
0
1hr
2hr
Fire Rating
For cavities in excess of 100mm wide, multi purpose
energy costs and carbon emissions.
brackets must be fitted to provide additional support (see
TECHNICAL INFORMATION
General benefits:
installation instructions). Profiled cladding sheets must be

Simple installation
fitted with C144 Firestop Blocks bonded into position with

Airtight smoke seal when used in conjunction with
PFC Corofil Slip Adhesive, in conjunction with the C450
You can request from our technical
Fastight Paint
installation. It is recommended that a cladding rail is
sales office the following information:
Improved acoustic performance when coated with
positioned as close as possible to the cavity barrier to
Fastight Paint
restrict movement/expansion of the cladding or curtain
 Material Safety Data Sheets

Maintenance free
walling.
 Installation Instructions

Unaffected by humidity and moisture

Good acoustic insulation

Airtight & Smoke Seal
PFC Corofil C450 Cavity Firestops can provide an airtight
and smoke seal by either:
Fire Rating
Cavity Size
Integrity
Insulation
Depth
10-100mm
120 mins
30 mins
80mm
101-600mm
120 mins
30 mins
100mm

Coating the exposed faces with Fastight Paint

Using foil encapsulated C450 Cavity Firestop and
sealing joints with PFC Corofil Foil faced tape
Thermal Performance
Acoustic
PFC Corofil C450 Cavity Firestop has been acoustically
The thermal conductivity of C450 mineral wool is 0.035
W/Mk
tested with a dense block wall (Rw = 58dB) in a 140mm
cavity and provided a Weighted Sound Reduction Index
Fibre Migration
(Rw) of up to 57dB when coated with Fastight Paint.
Fibre migration can be prevented by the use of

For further information on acoustic performance, please

consult out technical sales office with details of:

Size of cavity

Construction and acoustic rating of wall
Fastight Paint
Shrink wrapping cross sections up to
250mm Thick x 150mm Wide

Foil Facing
Specification
Install PFC Corofil C450 Cavity Firestops to provide up to
2 hours fire protection in all horizontal and vertical
cavities. Installation to be fully in accordance with
manufacturer’s instructions.
CAVITY BARRIERS
PFC Corofil C450 Cavity Firestop
C450 Cavity Firestop fitted between edge of floor slab and curtain
C450 Cavity Firestop used in conjunction with a vertical DPC to
walling with multi purpose brackets.
form blockwork cavity barriers.
ORDERING
When ordering this product you will
need the following information:
 Size of cavity
 Fire rating
 Quantity required (in linear metres)
 Fastight Paint quantity (in litres)
based on a coverage of 0.8m² per
litre
 Specify if you require the product
to be foil faced, shrink wrapped
or plain
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
CAVITY BARRIERS
PFC Corofil C470 Raised Floor Firestop
Application
Description
PFC Corofil C470 Raised Floor Firestop is used to form
PFC Corofil C470 Raised Floor Firestop is manufactured
cavity barriers at 20 metre intervals under raised access
from a high density, mineral wool. The material is supplied
flooring. Tested in accordance with BS 476:Part 20:1987,
in one metre lengths and is cut to suit the size of the
PFC Corofil C470 Raised Floor Firestop provides up to 2
cavity to be filled. The width of the product is dependent
hours fire protection.
on the fire rating required (see fire rating table). For
cavities in excess of 100mm high, multi purpose brackets
General benefits:
Tested to BS 476:Part 20:1987
0
1hr
2hr
must be fitted to provide additional support (see

Smoke seal
installation instructions). C470 Raised Floor Firestop is

Good acoustic insulation
installed under compression between the floor slab and

Simple installation
raised floor system, taking up any irregularities in the floor

Maintenance free
slab.

Unaffected by humidity and moisture
Fire Rating
Fire Rating
TECHNICAL INFORMATION
The system is suitable to provide up to 2 hours fire
You can request from our technical
protection in cavities up to one metre deep. With cavities
sales office the following information:
in excess of 100mm high, C470 Raised Floor Firestop
Depth of
Width of
Cavity
C470
10-100mm
80mm
120 mins
80 mins
101-1000mm
100mm
120 mins
100 mins
Integrity
Insulation
must be supported with multi-purpose brackets fixed to
 Material Safety Data Sheets
the floor slab, two per section. C470 material must be
 Installation Instructions
tightly cut around metal pipes and ductwork. Plastic
pipework must be fitted with PFC Corofil Intumescent Fire
Sleeves. The plastic pipework and cables must then be
sealed in with PFC Corofil Firestop Compound to
Acoustic
Tested up to a Weighted Sound Reduction Index (Rw) of
50dB in a 150mm high void. For further details, please
contact our technical sales office.
correspond with the thickness of the barrier. C470 can be
encapsulated with foil to provide an air plenum and smoke
seal.
Air Plenum
PFC Corofil C470 can provide an air plenum when foil
Airtight & Smoke Seal
encapsulated or coated with Fastight Paint.
PFC Corofil C470 can provide an airtight and smoke seal
by coating the exposed faces with Fastight Paint.
Fibre Migration
Fibre migration can be prevented by the use of:

Thermal Performance
The thermal conductivity of C470 mineral wool is 0.035
W/Mk
FIRE RATINGS

Fastight Paint
Shrink wrapping cross sections up to 250mm thick x
150mm wide

Foil encapsulation
Specification
Install PFC Corofil C470 Raised Floor Firestops to
provide up to 2 hours protection seal to the underside of
all raised access floor systems. Installation to be fully in
accordance with manufacturer’s instructions.
CAVITY BARRIERS
PFC Corofil C470 Raised Floor Firestop
ORDERING
C470 Raised Floor Firestop supported by multipurpose brackets
C470 Raised Floor Firestop encapsulated with foil to provide a
to form a cavity barrier.
combined air plenum, acoustic and fire barrier.
ORDERING
When ordering this product you will
need the following information:
 Height of cavity under floor
 Fire rating
 Specify if you require the product to
be foil faced, shrink wrapped or plain
 Quantity (in linear metres)
 Fastight Paint quantity (in litres)
based on a coverage of 0.8m² per
litre.
Please order from our technical sales
office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
CAVITY BARRIERS
PFC Corofil Rainscreen Fire Barrier System
Application
PFC Corofil RSB Rainscreen Fire Barrier Systems have been developed to provide horizontal firestopping for a variety of
Rainscreen Cladding Systems.
FIRE RATINGS
Tested in accordance with BS EN:1363-1:1999 and to the principles of EOTA TR31, the system has been shown to provide up
to 2 hours fire protection. PFC Corofil RSB can offer a free cavity of up to 46mm wide to allow water drainage and air circulation
Tested to BS EN:1363-1:1999
behind rainscreen panels.
0
1hr
2hr
General benefits:

RSB rapidly forms a fire barrier between the inner substrate and back of the panel

Suitable for cavity widths from 50 to 300mm wide

Fast and easy to install

Allows ventilation and moisture dissipation thus preventing damp problems

Supplied in 1 metre lengths, easy to handle and cut with a knife
Fire Rating
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
Description
Three versions of the system have been developed to reflect the build-up of the Rainscreen Cladding System, the required free
 Material Safety Data Sheets
gap and fire rating.
 Installation Instructions
RSB System
Minimum /
Maximum Gap Size
Free Air Gap
Need to remove
Support required
Fire
insulation layer
(no per l/m)
Rating
RSB 50/X
50-300mm
46mm
Yes
4 brackets
30 mins
Premium RSB 30/X
50-300mm
26mm
Yes
4 brackets
60 mins
RSB KP110/170
110-170mm
46mm
Kingspan K15 Board
Fix direct to
(Thickness 60 - 120mm)
4 x 50mm long dry
wall screws
90 mins
RSB50/X and Premium RSB25/X
Both the RSB50/X and Premium RSB25/X systems are manufactured from a high expansion intumescent strip pinned and
shrink wrapped to a high density mineral wool strip. All seals are factory assembled to suit the required cavity, allowing for the
required ventilation/drainage gap. The seals are referenced in terms of the overall gap size and the allowable free air gap:
RSB System
Overall Gap Size
RSB 50/100
100mm
Maximum Free
Width of Seal
Depth of Seal
Length
46mm
54mm
80mm
1000mm
Air Gap
RSB 50/250
250mm
46mm
204mm
80mm
1000mm
Premium RSB 25/100
100mm
26mm
74mm
80mm
1000mm
Premium RSB 25/250
250mm
26mm
224mm
80mm
1000mm
CAVITY BARRIERS
PFC Corofil Rainscreen Fire Barrier System
RSB KP110/170
The material is a high expansion, water resistant, foiled
The product offers contractors significant value
intumescent strip that can be directly fixed into Kingspan
engineering in terms of:
K15 insulation board, varying in thickness from 60 to
120mm thick, leaving a free cavity of up to 46mm wide.

Reduced labour costs

Reduced material costs in terms of fixings and
The strip is supplied in one metre lengths and this is
simply screwed through the face of the Kingspan K15
insulation board, using 4 x 50mm long dry wall screws per
brackets

Maintaining the continuity of the insulation layer
ORDERING
through floor zones
linear metre, ensuring that all joints are tightly abutted.
When ordering this product you will
need the following information in
order for us to determine the best
system to use:
 The build up of the rainscreen
cladding system
 The overall cavity size between
the back of the rain screen panel
and the inner wall (in mm)
 The size of the free air gap you
require for ventilation and drainage
PFC Corofil RSB Rainscreen Fire Barrier fixed direct to
Kingspan K15 insulation board.
(in mm)
PFC Corofil RSB Rainscreen Fire Barrier
 The type and thickness of insulation
that is being used
Specification
 Quantity required (in linear metres)
Install PFC Corofil RSB Rainscreen Fire Barriers in all
horizontal cavities behind Rainscreen Cladding System to
allow a ventilation/drainage gap. Installation to be fully in
Please order from our technical
sales office.
accordance with manufacturers instructions.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
CAVITY BARRIERS
PFC Corofil Ventilated Fire Barrier
Application
Description
An increasing number of cladding constructions require
The PFC Corofil VFB+ is manufactured using a high
the external cladding to be held away from the building
expansion intumescent strip mechanically fixed into a
structure to create a void. Whilst this can resolve any
high-density mineral wool.
FIRE RATINGS
ventilation and moisture dissipation problems, the cavity
Tested to BS 476:Part 20:1987
General benefits:
also creates a serious fire protection problem.
The cavity acts like an open chimney allowing fire to

Creates a fire barrier behind the cladding

Suitable for cavity widths from 50mm to 450mm
spread both vertically and horizontally around the building.
PFC Corofil VFB+ Rainscreen Fire Barrier System is
wide

designed to maintain the open cavity in normal conditions
but will expand to seal off the cavity in a fire.
Intumescent material expands to fill an open cavity
0
1hr
1½ hr
Fire Rating
of up to 44mm wide

Simple and quick installation, time saving of up to
TECHNICAL INFORMATION
75% over other barriers
Fire Rating
Tested
in
accordance
with
BS476
Part
20:1987,

Fire tested horizontally and vertically

Allows ventilation and moisture dissipation thus
preventing damp problems
PFC Corofil VFB+ has provided up to 30 minutes and 90
minutes respectively in combustible timber frame and

Cost effective
non-combustible constructions. The product meets the

Supplied in 1m lengths, easily cut with a knife
requirements of Approved Document B of the UK
Building Regulations.
PFC Corofil VFB+ Rainscreen Fire Barrier System has
been tested with the following cladding build-ups and
attained the following fire ratings with a free air gap of
44mm wide.
Substrates
Cavity Size
Brick / Block or Masonry
50 - 200mm
OSB Faced Timber Frame
Integrity
Integrity
(Horz)
(Vert)
90 mins
90 mins
201 - 300mm
60 mins
90 mins
301 - 400mm
30 mins
60 mins
25 - 300mm
30 mins
30 mins
50 - 200mm
30 mins
30 mins
50 - 200mm
90 mins
90 mins
PFC Corofil Ventilated Fire Barrier
OSB Faced Timber Frame
supporting Rainscreen
mineral wool slab (density
45-110 kg/m³) and a
Euroclass rating of A1
Concrete blocks with
cement board facing
supporting Rainscreen
mineral wool slab (density
45-110 kg/m³) and a
Euroclass rating of A1
The fire barriers are suitable for use in a variety of cladding
build-ups for cavities ranging from 50mm to 450mm wide.
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
CAVITY BARRIERS
PFC Corofil Ventilated Fire Barrier
Installation
Install PFC Corofil VFB+ Rainscreen Fire Barrier
System to all horizontal cavities with the rainscreen
system.
The barrier is physically supported via means of
galvanised steel brackets mechanically fixed to the
edges of floor slabs or wall linings (eg cement particle
boards). Installation to be in fully accordance with
manufacturer’s instructions.
Installation Diagrams
Ensure label side is facing out so that intumescent element
faces into cavity in case of fire. Adjacent lengths can be tightly
butted together.
ORDERING
When ordering this product you will
need the following information:
Fix VFB Plus with steel fixing brackets supplied using suitable noncombustible fixings. Product must be fixed at max. 500mm centres
(max. 250mm centres if being directly screw fixed in position). Each
 Overall size of cavity (in mm)
section of VFB Plus must be mechanically fixed.
 Type of substrate forming the
overall cavity
 Size of air gap required
 Type of insulation and thickness
(in mm)
 Quantity required (in linear metres)
Please order from our technical sales
office.
Brackets should be fitted at the centre point of the product. The
PFC Corofil
bracket should not protrude through the rigid intumescent element.
Maximum remaining air gap to the back of the cladding panel
Units 3-4
Cut the bracket down to size if required. If fixing with screws, see
is 44mm. Ensure Fire Barrier is free to expand in a fire situation.
King George Trading Estate
installation instructions.
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
LINEAR GAP SEALS
F30 670A JOINT FILLER
PFC Corofil C144 Firestop Strips and Blocks
Application
PFC Corofil C144 Firestop Strips provide firestopping for
PFC C144 Firestop Blocks are used to firestop profiles in
vertical and horizontal constructions joints and at the interface
roofing,
between
is
manufactured to fit the specific profile used and to suit the
manufactured to fit the specific size of the cavity and to suit the
width of the wall, beam or partition and the period of fire
width of the wall, beam or partition and the period of fire
protection required (see fire rating table).
compartment
walls
and
soffits.
The
strip
cladding
and
floor
decking.
The
blocks
are
FIRE RATINGS
Tested to BS 476:Part 20
& BS EN 1366-4
0
protection required (see fire rating table).
3hr
6hr
General benefits:

General benefits:



Product supplied to suit decking, roofing or cladding
profile
Product supplied to suit joint size

Simple installation
plasterboard into corrugations
Airtight and smoke seal when used in conjunction with

Fastight Paint

Available shrink wrapped to prevent fibre migration

Good acoustic insulation when applied with Fastight Paint

Unaffected by humidity and moisture

Maintenance free

Used in conjunction with C144 Firestop Blocks to seal
Used to seal top flanges of structural steel fire protection


Linear gap seals at tops of masonry walls in conjunction
Individual blocks to suit depth of wall or continuous
sections where corrugations run parallel with walls


Smoke and airtight seal when coated with Fastight Paint
Improved acoustic performance when coated with
Fastight Paint
Fire Rating

Available shrink wrapped to prevent fibre migration
Minimum Widths

Unaffected by humidity and moisture
1 Hour
75mm

Maintenance free
2 Hour
100mm
Fire Rating
3 Hour
150mm
4 Hour
175mm
6 Hour
200mm
Acoustic
PFC Corofil C144 Firestop Strips have been tested with a
25mm gap in a reference wall giving a weighted sound
Tested in accordance with BS 476:Part 20 and BS EN 1366-4,
reduction index of 58db. C144 Firestop Strip coated with
PFC Corofil Firestop Strips and Blocks will provide up to 6
Fastight Paint gave a weighted sound reduction index of 57db.
hours fire protection.
PFC Corofil C144 Firestop Blocks have been tested with a
Smoke Seal / Airtightness
TECHNICAL INFORMATION
and compartmentation
with C144 Firestop Strip
between top of blockwork to underside of profile sheeting
Fire Rating
Used for sealing partition heads. no need to scribe
twin frame plasterboard partition (250mm wide, Rw = 67db).
PFC Corofil C144 Cavity Firestop Strips and Blocks provide a
The blocks were installed at 250mm long and coated both
smoke seal if the external faces are coated with Fastight Paint.
sides with Fastight Paint which gave a Weighted Sound
Reduction Index (Rw) of 62dB.
Specification
Install PFC Corofil C144 Firestop Strips to provide 1,2,3,4 or 6
For further information on acoustic performance, please
hour fire rated joints. Install Corofil C144 Firestop Blocks to
consult out technical sales office with details of:
provide 1,2,3,4 or 6 hour rating to seal all roof, wall and floor

Size of gap
deck profiles. Installation to be fully in accordance with

Construction and acoustic rating of wall
manufacturer’s instructions.
Thermal Performance
The thermal conductivity of C144 mineral wool is 0.035 W/Mk
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
LINEAR GAP SEALS
PFC Corofil C144 Firestop Strips and Blocks
ORDERING
When ordering this product you will
need the following information:
C144 Firestop Strip
PFC Corofil C144 Firestop Strip installed between head of wall
 Fire rating
to underside of concrete soffit.
 Joint size
Profile sheeting showing the dimensions of the corrugations
 Quantity required (in linear metres)
to be filled with C144 Firestop Blocks.
C144 Firestop Blocks
 Fire rating
 Profile sheet reference or exact
profile dimensions
 Large or small profile to be filled
 Individual blocks or linear metre run of
corrugations
 Quantity required (individual blocks or
linear metres)
PFC Corofil C144 Firestop Blocks installed above steel beam to
underside of profile corrugated sheeting.
 Fastight Paint quantity (in litres)
based on a coverage of 0.8m per
litre
 Specify if you require for the blocks
to be shrink wrapped.
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
LINEAR GAP SEALS
F30 670A JOINT FILLER
PFC Corofil C500 Intumescent Expansion Joint
Application
Description
PFC Corofil C500 Intumescent Expansion Joint provides
PFC Corofil C500 Intumescent Expansion Joint is a
an easy retro-fit solution to firestop existing construction
compressible strip formed by shrink wrapping a graphite
joints up to 75mm thick in fire rated walls. Tested in
based intumescent polymer to both faces of a mineral
accordance with BS 476:Part 20, PFC Corofil C500
fibre core. The material is supplied in one metre lengths to
Intumescent Expansion Joint provides up to 4 hours fire
suit the joint to be filled. The width of the product is
protection.
dependent on the fire rating required (see fire rating
FIRE RATINGS
Tested to BS 476:Part 20
0
2hr
4hr
Fire Rating
table).
General benefits:

Simple to install
The material is simply compressed by hand and is then

Water resistant
pushed into the space. Adjacent pieces of the product are

Maintenance free
tightly butted together. There is no need to use any
Fire Rating in Walls
TECHNICAL INFORMATION
adhesives or intumescent sealant in conjunction with the
You can request from our technical
product.
sales office the following information:
In a fire, the graphite based intumescent
material swells to form a hard char, which prevents the
Joint Size
Size of Product
Fire Rating
Insulation
1-14mm
16 x 25mm
2 Hours
Single
16 x 50mm
4 Hours
Single
15-30mm
32 x 25mm
2 Hours
Dual
Corofil C500 Cavity Firestop is suitable for use in:
32 x 50mm
4 Hours
Dual

Blockwork cavities
31-50mm
52 x 50mm
4 Hours
Dual
51-75mm
78 x 50mm
4 Hours
Dual

Curtain wall / Concrete slab interfaces

Expansion joints

Structural joints
For details of fire rating in floors, please contact our
passage of fire and smoke through the joint.
 Material Safety Data Sheets
 Installation Instructions
technical sales office.
ORDERING
When ordering this product you will
need the following information:
Fibre Migration
PFC Corofil C500 Intumescent Expansion Joint is shrink
 Fire rating
wrapped to prevent mineral fibre migration.
 Joint size
 Quantity required (in linear metres)
Specification
Install PFC Corofil C500 Intumescent Expansion Joint to
Please order from our technical
provide up to 4 hours fire protection to all construction
sales office.
joints up to 75mm thick. Installation to be fully in
accordance with manufacturer’s instructions.
PFC Corofil
Units 3-4
King George Trading Estate
PFC Corofil C500 Intumescent Expansion Joint is used to
Davis Road
seal pre-formed construction joints in fire walls.
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
LINEAR GAP SEALS
F30 670A JOINT FILLER
PFC Corofil C500X Intumescent Movement Joint
Application
Description
PFC Corofil C500X Intumescent Movement Joint is a
PFC Corofil C500X Intumescent Movement Joint is a highly
compressible product to fill fire rated joints in walls. Tested in
compressible strip formed by laminating fire retardant foam to
accordance with BS 476:Part 20, PFC Corofil C500X provides
a graphite based intumescent polymer. The material is
up to 4 hours fire protection.
delivered to site in pre-formed sections. The section size
depends on the joint size and the fire rating that needs to be
General benefits:

FIRE RATINGS
Tested to BS 476:Part 20
0
2hr
4hr
achieved (see fire rating table).
Simple to install

Water resistant
The material is simply compressed by hand and is then

Maintenance free
pushed into the gap. Adjacent pieces of the product are tightly
butted together. There is no need to use any adhesives or
intumescent sealant in conjunction with the product. In a fire,
Fire Rating in Walls
Joint Size
1-10mm
11-25mm
26-50mm
Integrity
Fire Rating
TECHNICAL INFORMATION
the graphite based intumescent material swells to form a hard
Insulation
Size of Product
Product
Code
char which prevents the passage of fire and smoke through
You can request from our technical
the joint.
sales office the following information:
 Material Safety Data Sheets
240 mins
235 mins
14mm x 12mm
C500X1
240 mins
228 mins
14mm x 25mm
C500X1A
120 mins
16 mins
29mm x 12mm
C500X2
PFC Corofil C500X Intumescent Expansion Joint is suitable for
240 mins
145 mins
29mm x 25mm
C500X3
use in:
120 mins
23 mins
56mm x 25mm
C500X4

For details of fire rating in floors, please contact our technical
sales office.
Blockwork cavities

Expansion joints

Structural joints
 Installation Instructions
ORDERING
When ordering this product you will
Acoustic
need the following information:
Please consult our technical sales office with details of:
 Wall / floor construction
 Fire rating
 Acoustic rating required
 Joint size
 Quantity required (in linear metres)
Please order from our technical
sales office.
PFC Corofil C500X Intumescent Movement Joint firestopping
PFC Corofil
vertical expansion joint.
Units 3-4
King George Trading Estate
Specification
Davis Road
Install PFC Corofil C500X Intumescent Movement Joint to
Chessington
PFC Corofil C500X Intumescent Movement Joint compressed
provide up to 4 hours fire protection. Installation to be fully in
Surrey KT9 1TT
into blockwork joints.
accordance with manufacturer’s instructions.
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
LINEAR GAP SEALS
PFC Corofil Intumescent Firestrip Tape
Application
Description
PFC Corofil Intumescent Firestrip Tape is a
PFC Corofil Intumescent Firestrip Tape should be
pre-formed,
applied to surfaces at a temperature range of
high
performance,
intumescent
polyisobutylene (PIB) based sealing tape.
between +4 °C and +30 °C.
This product has a multitude of applications where
For best performance the surfaces should be
joints need to be formed to seal against fire, water
clean, dry and grease free. The product should be
ingress and for providing an air tight seal.
unwound and lightly pressed into position leaving
the release paper in place.
The strip can be used to seal dry wall track heads
where they interface with construction soffits.
On forming the joint the release paper is removed
and the closing surface pushed firmly in place,
The product is cost effective, non toxic and
pressure applied along the length of the joint and
requires no tools to apply.
mechanically fixed if necessary.
Product Data
TECHNICAL INFORMATION
Colour
White
Dimensions
3mm thick x 25mm wide x 3.6 linear metres long
Shelf Life
18 months in ambient conditions
Life
In excess of 20 years
U.V. Resistance
Excellent
Service Temperature Range
-40 to +90 degrees C
Joint Movement
Up to 15%
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
ORDERING
Please order from our technical sales
Compatibility
office.
Very good adhesion to most surfaces and compatible with commonly used construction materials. For
further information please contact our technical department.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
LINEAR GAP SEALS
PFC Corofil Acoustic Profile Fillers
Application
PFC Corofil tissue faced acoustic profile fillers are
designed to fit into the corrugations of perforated
metal profiles used for roof decking. They reduce
sound reverberation around a room and significantly
contribute to the comfort of the occupants of the
building.
General benefits:

TECHNICAL INFORMATION
Provide a large absorptive surface without the
expense, aesthetic problems or inconvenience of
You can request from our technical
suspended acoustic systems.


Tissue facing reduces mineral fibre migration
PFC Corofil Acoustic Profile Fillers installed in the
Available to suit any profile and density to meet
corrugations of perforated profile sheeting.
sales office the following information:
 Material Safety Data Sheets
the requirements of the acoustic specification.
 Installation Instructions
Specification
PFC Corofil tissue faced acoustic profiles are supplied
in 1200mm lengths in either white or black. They are
ORDERING
available in a range of densities to meet the roofing
manufacturer’s system specification. Installation to be
in full accordance with the manufacturer’s instructions.
Performance
 Profile sheet reference or exact
Frequency (Hz)
Mounting
125
need the following information:
 Density required
Absorption coefficients for selected mineral fibre slabs
Slab Thickness
When ordering this product you will
250
500
profile dimensions
1K
2K
4K
0.82
50mm
Direct
0.11
0.60
0.96
0.94
0.92
75mm
Direct
0.34
0.95
1.00
0.82
0.87
0.86
30mm
Direct
0.10
0.40
0.80
0.90
0.90
0.90
30mm
300mm gap
0.40
0.75
0.90
0.80
0.90
0.85
75mm
Direct
0.40
0.75
0.90
0.80
0.90
0.85
50mm
Direct
0.20
0.75
0.90
0.85
0.90
0.85
50mm
300mm gap
0.65
0.55
0.75
0.85
0.75
0.85
 Black or white of tissue facing
 Quantity required (in 1.2m lengths)
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SEALANTS
Certificate number: FS453/05
F30 670A SEALANT
PFC Corofil Acoustic Intumescent Sealant
Application
PFC Corofil Acoustic Intumescent Sealant is suitable
for sealing joints and service penetrations in fire walls,
partitions, fire rated door frames and glazing systems.
Tested in accordance with BS 476:Parts 20 & 22:1987
and BS EN 1366-4, PFC Corofil Acoustic Intumescent
Sealant provides up to 4 hours fire protection in joints
of up to 30mm wide. In addition to the fire rating the
sealant may be used to seal joints in party walls to
provide an acoustic seal.
Description
PFC Corofil Acoustic Intumescent Sealant is a high
FIRE RATINGS
specification, one part water based acrylic sealant,
extruded from a cartridge loaded into a standard
gap to be filled and the fire rating required (see fire
Tested to
BS 476:Parts 20 & 22:1987
BS EN 1366-4
rating).
0
sealant gun. The depth of the joint will depend on the
All surfaces must be thoroughly clean and free of
bond breaking contaminants prior to application of the
2hr
4hr
Fire Rating
sealant. No priming is required for most construction
substrates, however, it is recommended that a small
Acoustic
PFC Corofil Acoustic Intumescent Sealant provides a
TECHNICAL INFORMATION
area be tested on substrates.
You can request from our technical
Weighted Sound Reduction Index (Rw) of up to 57dB.
sales office the following information:
Please consult our sales office with details of:
The sealant should not be applied if the ambient

Type of construction
temperature is below 5ºC as adhesion will be

Required acoustic rating
impaired. The sealant is fast curing approximately 15
 Material Safety Data Sheets

Size of joint
minute tack free time. When fully cured, the sealant is
 Installation Instructions
overpaintable. Under fire conditions the sealant forms
a fire resistant ash.
Airtight & Smoke Seal
PFC Corofil Acoustic Intumescent Sealant will provide
an airtight and cold smoke seal.
Fire Rating
Joint Size
Depth of Sealant
Integrity
Insulation
Backing
Type of Seal
10mm
10mm
240 mins
30 mins
PE Foam
Single
15mm
10mm
240 mins
30 mins
PE Foam
Single
20mm
15mm
240 mins
120 mins
PE Foam
Dual
20mm
20mm
240 mins
60 mins
C144 Firestrip
Single
30mm
15mm
240 mins
120 mins
PE Foam
Dual
30mm
15mm
240 mins
60 mins
C144 Firestrip
Single
 Product Certification
SEALANTS
PFC Corofil Acoustic Intumescent Sealant
Sizes
PFC Corofil Acoustic Intumescent Sealant is available
in 310ml cartridges, 600ml foil packs and 900ml
jumbo cartridges.
PFC Corofil Acoustic Intumescent Sealant sealing
around
service
penetrations
passing
through
blockwork wall.
PFC Corofil 900ml Jumbo Cartridge
ORDERING
When ordering this product you will
need the following information:
 Size of cartridge
 Quantity required
PFC Corofil 600ml Foil Pack
Please order from our technical sales
Colours
The sealant is available in white and grey.
PFC
Corofil
Acoustic
Intumescent
Sealant
in
office.
blockwork joints.
PFC Corofil
Coverage
One 310ml cartridge will provide the following
coverage rates:
Yield per
Joint Size
Depth of Sealant
10mm
10mm
3.10 per l/m
20mm
15mm
1.03 per l/m
30mm
20mm
0.51 per l/m
Cartridge
Units 3-4
Specification
King George Trading Estate
Install PFC Corofil Acoustic Intumescent Sealant to
Davis Road
provide up to 4 hours fire protection in all joints up to
Chessington
30mm in all firewalls. Installation to be fully in
Surrey KT9 1TT
accordance with manufacturer’s instructions.
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SEALANTS
F30 670A SEALANT
PFC Corofil Fire Resistant Silicone Sealant
Application
Description
PFC Corofil Fire Resistant Silicone Sealant is a one part
PFC Corofil Fire Resistant Silicone Sealant is a high
alkoxy cure silicone which has excellent unprimed
specification, extruded from a cartridge loaded into a
adhesion to most building surfaces and is designed to be
standard sealant gun.The depth of the joint will depend on
used in joints with high movement capability or where they
the gap to be filled and the fire rating required (see fire
are formed between dissimilar substrates (e.g. steel and
rating).
FIRE RATING
Tested to BS EN 1366-4
0
masonry). Tested in accordance with BS EN 1366-4, PFC
Corofil Fire Resistant Silicone Sealant can provide up to 4
All surfaces must be thoroughly clean and free of bond
hours fire protection.
breaking contaminants prior to application of the sealant.
2hr
4hr
Fire Rating
No priming is required for most construction substrates;
however, it is recommended that a small area be tested
Fire Rating
on substrates.
Joint
Sealant
Backing
Size
Depth
Material
15mm
10mm
PE
10mm
25mm
15mm
40mm
25mm
Dimensions
25mm
diameter
Mineral
15mm thick x
wool
10mm depth
PE
30mm
diameter
Mineral
40 x 25mm
wool
depth
Integrity
Insulation
(mins)
(mins)
Single
240
120
Dual
240
240
Single
240
120
Dual
240
240
Seal
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
 Product Certification
ORDERING
Coverage
PFC Corofil Fire Rated Silicone is available in 310ml
PFC Corofil Fire Resistant Silicone Sealant in
cartridges. One cartridge will provide the following
blockwork joints.
When ordering this product you will
need the following information:
coverage rates:
 Quantity required
Colours
Joint Size
Metres per Litre
6mm x 6mm
27.75
9mm x 6mm
18.50
12mm x 9mm
9.25
Install PFC Corofil Fire Resistant Silicone Sealant to
18mm x 12mm
4.75
provide up to 4 hours fire protection in all joints up to
PFC Corofil
25mm x 10mm
4.0
40mm. Installation to be fully in accordance with
Units 3-4
manufacturer’s
King George Trading Estate
The silicone is available in white.
Please order from our technical sales
Specification
office.
instructions.
Quantity
contained
in
The sealant should not be applied if the ambient
cartridge is 310ml. Once installed the sealant can offer up
Davis Road
temperature is below 5°C as adhesion will be impaired.
to 25 years service when correctly applied.
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SEALANTS
PFC Corofil High Expansion Intumescent Sealant
Application
PFC Corofil HE Intumescent Sealant is recommended for use where a flexible and durable fire resistant seal is required. In the
FIRE RATINGS
event of fire, the sealant exerts a positive pressure to make a joint, smoke, gas or water tight seal. Tested in accordance with
BS EN:1366-3, PFC Corofil HE Intumescent Sealant will provide up to 2 hours fire protection.
Tested to BS EN:1366-3
0
Suitable applications include:

Combustible and non combustible pipes

Cables (single cables or bunches of cables)

Other permanent services

Suitable for masonry/plasterboard walls and concrete floors
1hr
2hr
Fire Rating
TECHNICAL INFORMATION
You can request from our technical
Fire Rating
sales office the following information:
In 2 hour plasterboard wall:
 Material Safety Data Sheets
Service Penetration
Hole Size
In Wall
Design of Joint
Depth of
Sealant
Fire Integrity
55mm Diameter HDPE/PVC Pipe
Up to
100mm x 100mm
25mm annular joint in Patrice fixed coated panel
(50mm thick) on both sides of wall
40mm
120 mins
Up to
150mm x 150mm
25mm annular joint in Patrice fixed coated panel
(50mm thick) on both sides of wall
110mm Diameter HDPE/PVC Pipe
40mm
120 mins
Service Penetration
Hole Size
Design of Joint
Depth of
Sealant
Fire Integrity
110mm Diameter HDPE / PVC Pipe
160mm
Mineral wool shutter (25mm thick) / sealant*
75mm
90 mins
In concrete floors:
* Mineral wool shutter removed before test
In 150mm thick masonry walls:
Service Penetration
Hole Size
in Wall
Design of Joint
Depth of Sealant /
Backer
Fire Integrity
Fire
Insulation
Cable Tray (150mm x 25mm)
Up to 200mm x 100mm
Sealant / Coated Panel /
Wool* / Sealant
40 / 50 / 40mm
120 mins
120 mins
Cable Bunch (100mm diameter)
Up to 150mm Diameter
(25mm annular gap)
Sealant / Coated Panel /
Wool* / Sealant
40 / 50 / 40mm
120 mins
60 mins
Sealant / Coated Panel x 2
40 / 50mm
(both sides)
120 mins
120 mins
Sealant / Coated Panel x 2
40 / 50mm
(both sides)
120 mins
120 mins
HDPE / PVC Pipe (110mm)
HDPE / PVC / ABS Pipe (50mm)
* 10mm mineral fibre wool backer
Up to 162mm Diameter
(25mm annular gap)
Up to 150mm Diameter
(50mm annular gap)
 Installation Instructions
SEALANTS
PFC Corofil High Expansion Intumescent Sealant
Description
PFC Corofil HE Intumescent Sealant is an easy to apply waterborne acrylic emulsion sealant containing graphite which expands
at temperatures above 135ºC sealing around various penetrations and services to prevent the passage of smoke and flames.
Application Procedure
Application Temperature Range
+ 4°C to + 35°C
Service Temperature Range
- 15°C to 70°C
All surfaces must be clean and sound, free from dirt, grease and other contamination. Wood plaster and brick may be damp but
not running wet. Use mechanical abrasion to clean porous surfaces before application. For extra performance in movement
situations, a primer can be prepared by diluting 1 part sealant with 2 parts of water and mixing thoroughly. The primer should be
brush applied and allowed to dry for 2 to 3 hours before applying sealant. Alternatively a standard PVA sealer may be used on
the surface.
Prepare joint by cleaning and priming if necessary, as previously detailed. Cut nozzle to the desired angle and gun firmly into
the joint to give a good solid fill. Strike off the sealant flush with the joint sides within five minutes of application, before surface
skinning occurs. A small amount of shrinkage will occur on curing. If a flush finish is required, fill the joint slightly proud of the
surface to allow for shrinkage.
Limitations

The sealant is not intended for application on bituminous substrates or substrates that can exude certain oils and
plasticizers or solvents.

The sealant is not recommended for submerged joints or areas exposed to high abrasion.

The sealant is not suitable for food contact or medical applications.
ORDERING
When ordering this product you will
need the following information:
 Quantity required
Please order from our technical sales
office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax+ 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SEALANTS
Certificate number: FS453/13
PFC Corofil LUL Intumescent Sealant
Application
Description
PFC Corofil LUL Intumescent Sealant is recommended for use
PFC Corofil LUL Intumescent Sealant is a one part water
in low movement joints up to 30mm wide in underground
based acrylic sealant. This specially formulated sealant has an
applications. Tested in accordance with BS 476:Part 20:1987,
exceptionally low smoke emission characteristic which allows
PFC Corofil LUL Intumescent Sealant will provide up to
it to be used in fire resistant joints and around service
2 hours fire protection with a single seal using PFC Corofil
penetrations in underground applications.
C144 Firestop Strip backing material. Suitable applications
It is suitable for sealing joints and service penetrations in
include sealing joints around:
masonry and plasterboard walls and fire rated door frames.
General benefits:
Sealing around Pipes and Cables
 Non combustible pipes with annular gaps of up to 60mm
Up to 2 hours with a single seal with a PFC Corofil C144
wide
Firestop Strip mineral wool backer material (30mm depth) with
annular gaps of up to 15mm wide on non combustible pipes
 Other permanent services
and 10mm wide around single cables of up to 15mm diameter.
 Sealing joints in masonry walls, steel to masonry, softwood
PFC Corofil LUL Intumescent Sealant is available in white and
Block to
block
Block to
steel
Block to
softwood
Plasterboard
(15mm thick)
TECHNICAL INFORMATION
You can request from our technical
grey in 310ml cartridges and 600ml foil eco friendly sausage
 Material Safety Data Sheets
packs.
 Installation Instructions
Maximum
Joint Size
Sealant
Depth
Fire
Integrity
Fire
Insulation
All surfaces must be clean and sound, free from dirt, grease
30mm
15mm
120mm
30 mins
construction substrates; however, it is recommended that a
25mm
15mm
120mm
30 mins
small area be tested on substrates. The sealant should not be
25mm
20mm
30mm
30 mins
applied if the ambient temperature is below 5 degrees C as
15mm
15mm
30mm
30 mins
adhesion will be impaired. The sealant is fast curing
and other contamination. No priming is required for most
approximately 15 minute tack free time. When fully cured the
Corofil C144 Firestop Strip mineral wool backer material (30mm
depth)
Double Seals
Block to
block
Block to
steel
Block to
softwood
Plasterboard
(15mm thick)
2hr
Application Procedure
All samples were single seals installed on fire side with a PFC
Substrates
1hr
 Product Certification
Single Seals
Substrates
0
sales office the following information:
Colour and Sizes
Fire Rating (Sealing Joints in Walls)
Tested to BS 476:Part 20:1987
Fire Rating
 Cables (single cables with diameters up to 15mm diameter)
to masonry, plasterboard.
FIRE RATINGS
Maximum
Joint Size
Sealant
Depth
Fire
Integrity
Fire
Insulation
30mm
15mm
120 mins
30 mins
25mm
15mm
120 mins
30 mins
25mm
20mm
30 mins
30 mins
15mm
15mm
60 mins
60 mins
sealant is over paintable.
When ordering this product you will
need the following information:
 Quantity required
Please order from our technical sales
LUL Testing
Test
Smoke Density
Toxicity Tests
Oxygen Index Value
ORDERING
Result
Ao (max) = 0.0170
CIT value = 2.05
OI = 31.8
office.
PFC Corofil
Units 3-4
Limitations
King George Trading Estate
The sealant is not recommended for submerged joints or
Davis Road
areas exposed to high abrasion or movement.
Chessington
Surrey KT9 1TT
Specification
Install PFC Corofil LUL Acoustic Intumescent Sealant to
Tel: + 44 (0) 208 391 0533
All seals to be backed with PFC Corofil C144 Firestop Strip mineral
provide up to 4 hours fire protection in all joints up to 30mm in
Fax: + 44 (0) 208 391 2723
wool backer material (30mm depth)
all firewalls. Installation to be fully in accordance with
manufacturer’s instructions.
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
Certificate number: FS453/02
PFC Corofil Coated Panel System
Application
Description
PFC Corofil Coated Panel System is used to firestop
PFC Corofil Coated Panel System comprises of three
mechanical and electrical services where they pass
elements:
FIRE RATINGS
through fire rated walls. Tested in accordance with
BS476:Parts 20 & 22, PFC Corofil Coated Panel System
provides up to 4 hours fire protection.
 PFC Corofil Coated Panel
 PFC Corofil Acoustic Intumescent Sealant
General benefits:
high-density rock fibreboard with a fire rated ablative
 Simple installation
coating. The coated panels are simply cut and friction
 Light weight
 Suitable to make good around most types of service
penetrations
 Unaffected by humidity
 Maintenance free
fitted between the services and the edges of the structure.
Plastic pipework needs to be sealed with PFC Corofil High
You can request from our technical
Expansion Intumescent Sealant or sleeved with Insulated
sales office the following information:
system.
 Low smoke emission
Fire Rating
on the edges of the panel to form a barrier with
Panel
Tested
Configuration
Block Wall
Integrity
Insulation
1 x 50mm
4 Hours
1 Hour
2 x 50mm
1 Hour
19 mins
2 x 50mm
2 Hour
15 mins
surrounding structure. All joints in the barrier are pointed
in with Acoustic Intumescent Sealant to form a monolithic
layer. The Ablative Coating is largely used to make good
any damaged coating or for a more aesthetic finish. In
plasterboard partitions, the panel must be fitted to both
sides of the wall to fire protect the studs. The panels can
be fitted by either a patrice fix or by being cut into
openings. For large floor openings we would advise using
PFC Corofil Firestop Compound (see technical data
Acoustic
sheet).
Weighted Sound Reduction Index (Rw) of up to 52dB.
Contact our sales office with details of:
 Wall construction
 Acoustic rating required
 Size of opening
Cold Smoke and Air Tight Seal
PFC Corofil Coated Panel System will provide a cold
Fibre Migration
PFC Corofil Coated Panel System will not allow fibre
migration as all exposed edges of mineral fibre are
encapsulated with an acrylic based polymer.
Colour
White matt finish. Can be over painted if desired.
smoke seal around services penetrating through
compartment walls.
 Material Safety Data Sheets
 Installation Instructions
The Acoustic Intumescent Sealant is used as an adhesive
Partition (Patrice)
TECHNICAL INFORMATION
Fire Sleeves prior to installation of the coated panel
Construction
4hr
PFC Corofil Coated Panels are manufactured by spraying
 No coat back required
Plasterboard
1hr
Fire Rating
 Good acoustic insulation (up to Rw of 52dB)
Partition
0
 PFC Corofil Ablative Coating
 Cold smoke and air tight seal
Plasterboard
Tested to BS 476:Parts 20 & 22
(1200mm x 600mm x 50mm)
Specification
Install PFC Corofil Coated Panel System to provide up to
4 hours fire rating to all service penetrations passing
through all fire rated walls. Installation to be fully inn
accordance with manufacturer’s instructions.
 Product Certification
SERVICE PENETRATIONS
PFC Corofil Coated Panel System
PFC Corofil Coated Panels firestopping service penetrations
PFC Corofil Coated Panel fitted around service penetrations
in plasterboard partition (no coat back required).
in bulkhead above fire door (no coat back required).
ORDERING
When ordering this product you will
need the following information:
 Fire rating
 Details of service penetrations
 Quantity required
PFC Corofil Coated Panels installed as a patrice surface mounted to outside of plasterboard partition fitted around plastic
pipes with PFC Corofil High Expansion Intumescent Sealant (no coat back required).
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
Certificate number: FS453/03
PFC Corofil Ablative Coating
Application
Description
PFC Corofil Ablative Coating is ready to use and designed
PFC Corofil Ablative Coating is recommended for use
to enhance, seal and protect mineral fibre panels. It is
where the surface is irregular and requires both filling and
based on a durable polymer system with inert fillers, non-
coating to achieve a smooth uniform finish. The coating
halogenated fire retardants and a preservative to resist
can be applied in layers up to 10mm thick per application.
microbial attack. The ablative property of the coating
resists flame spread and protects the mineral fibre panel.
The coating is available in white and can be over painted
if desired.
General benefits:


Designed to be spray applied onto fire rated mineral
Limitations
fibre panels.
PFC Corofil Ablative Coating is not intended for
Dries to give a sound, flexible white surface finish.
application on bituminous substrates or substrates that
During installation of mineral fibre panels the cured
can exude certain oils and plasticizers or solvents. The
coating reduces de-lamination and increases surface
coating is not recommended for use in submerged joints
stability for adhesive and fixing sealant application.
or areas exposed to high abrasion and is not suitable for
food contact or medical applications.
TECHNICAL INFORMATION
Technical Data
Form
Ready to use viscous paste
Cure System
Water loss
You can request from our technical
Colour
White
sales office the following information:
Specific Gravity
1.3 - 1.4
pH
8.5 – 9.2
Flashpoint
None
Solids Content (%w/w)
> 58%
Application Temp Range
+10°C to +30°C
 Material Safety Data Sheets
ORDERING
Service Temp Range
-15°C to +75°C
Shelf Life
Up to 12 months when stored
When ordering this product you need
in unopened containers under
the following information:
cool dry conditions. AVOID
FROST and extremes of
temperature.
Durabiltity
 Quantity required
Up to 15 years when used as
recommended.
Please order from our technical
sales office.
PFC Corofil
Units 3-4 King George Trading Estate
Davis Road
Chessington
Surrey KT19 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.co.uk
www.pfc-corofil.co.uk
SERVICE PENETRATIONS
Certificate number: FS453/10
P12 36A INTUMESCENT FOAM
PFC Corofil C25 Cable Firestop
Application
Description
PFC Corofil C25 Cable Firestop has been developed to
PFC Corofil C25 Cable Firestop is a compressible fire
effectively seal cable bunches in electrical trunking and
retardant foam which is laminated both sides with a
cable trays where they pass through fire rated walls and
graphite based intumescent polymer. C25 Cable Firestop
floors. Tested in accordance with BS476:Part 20, C25
is supplied in sections measuring 60mm wide x 25mm
Cable Firestop will provide up to 4 hours fire protection.
thick x 1m long.
General benefits:
The product is cut along its length to suit the width of the
 Simple to install
cable tray or electrical trunking to be firestopped.
 Cables can be easily added or removed
For example, with 100mm x 50mm electrical trunking the
 No de-rating of cables
product would be cut into sections of 100mm long.
 Maintenance free
 Dry system
C25 Cable Firestop is then laid on top of the cable runs
 3rd Party Certificated
orientating the product so that the 60mm width lies across
the width of the wall or the depth of the floor slab. It is
then layered to fill the complete depth of the electrical
Fire Rating
trunking or the cable tray ensuring electrical trunking lids
Service Penetration
Fire Rating
Cable Tray
4 Hours
Electrical Trunking
4 Hours
are fixed back after installing the product.
FIRE RATINGS
Tested to BS476:Part 20
0
2hr
4hr
Fire Rating
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
 Product Certification
ORDERING
When ordering this product you will
need the following information:
 Size of cable tray or electrical
trunking
 Approximate percentage fill
of cables
 Quantity required (in linear meters)
PFC Corofil Coated Panel System fitted around cable tray in
compartment wall. PFC Corofil C25 Cable Firestop compressed
into the interior of cable tray.
PFC Corofil C25 Cable Firestop filling electrical trunking and
Please order from our technical
cable trays where they pass through compartment floors. PFC
sales office.
Corofil Compound making good service riser floor.
PFC Corofil
Specification
Units 3-4
Install PFC Corofil C25 Cable Firestop to provide up to 4
King George Trading Estate
hours fire protection in all electrical trunking and cable
Davis Road
trays where they pass through fire rated walls and floors.
Chessington
Installation to be fully in accordance with manufacturers
Surrey KT9 1TT
instructions.
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil RF Cable Transits
Application
Description
PFC Corofil RF Cable Transits allow cables and all
PFC Corofil Cable Retro-Fit Transits are simply
cabling to be removed and replaced without the need
clipped around the cables and pipes via a crimped
to disrupt the integrity of existing fire seals. Unlike
edge. Once in situ they can be either penetrated by
conventional firestopping, cabling can be regularly
additional services or pulled out from the wall or floor
changed without the need for maintenance or repair,
and re-opened. In floors the bottom end of the sleeve
providing a fire rated cable management system.
must protrude 40mm under the soffit level to enhance
rapid thermal transmission to the Intumescent layer
FIRE RATINGS
Tested to BS:EN1366-3
0
1hr
PFC Corofil RF Cable Transits have been tested in
and to allow Building Control to ensure that a seal has
accordance with BS EN:1366-3 penetration seals in
been installed. Make good between the sleeve and
concrete floors and plasterboard partitions with cables
the concrete floor slab using PFC Corofil Firestop
for up to 2 hours fire rating.
Compound (minimum depth of 70mm).
General benefits:
PFC

Easy to fit
manufactured from a 0.7mm thick stainless steel

Allow frequent replacement of cables
sleeve with an inner layer of graphite based

Suitable for core drilled holes
intumescent polymer which reacts at approximately
 Material Safety Data Sheets

Available with a cold smoke seal gasket
140°C in fire conditions.
 Installation Instructions

Maintenance free
Corofil
Cable
Retro-Fit
2hr
Fire Rating
TECHNICAL INFORMATION
Transits
are
You can request from our technical
sales office the following information:
ORDERING
Sizes
Transits are available in the sizes as specified in the
When ordering this product you will
table below. Other sizes are available or made to
need the following information:
order. Please enquire with our technical sales team
for further details.
 Details of cables
 Quantity required
PFC Corofil RF Cable Transit designed to fit around cable tray.
Please order from our technical
sales office.
Outside Diameter
Internal Diameter
Length
50mm
30mm
160mm
PFC Corofil
100mm
70mm
160mm
Units 3-4
150mm
130mm
160mm
King George Trading Estate
100mm x 100mm
80mm x 80mm
160mm
Davis Road
100mm x 200mm
80mm x 180mm
160mm
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
Certificate number: FS453/09
PFC Corofil Intumescent Pillows
Application
Description
PFC Corofil Intumescent Pillows will provide up to 4 hours fire
The pillows are simply packed tightly in between penetrating
protection to metal services and cables passing through
services and the wall. In a floor, pillows are additionally
compartment floors and walls.
supported by means of a mesh support system (see diagram).
General benefits:
Under fire conditions, the pillows expand several times their
 Simple to install
original volume to form an effective seal around service
 Easy to remove and reinstate whilst changing services
penetrations. Pillows are suitable for use with:
FIRE RATINGS
Tested to BS 476:Part 20 & EN 1366-3
0
 Maintenance free
 Dry System
rd
 3 Party Certificated
2hr
4hr
Fire Rating
 Metal Pipework
 Cable Trays
 Electrical Trunking (inside and outside)
TECHNICAL INFORMATION
Fire Rating
You can request from our technical
PFC Corofil Intumescent Pillows will provide 4 hours fire
sales office the following information:
integrity and 2 hours insulation rating as tested in accordance
with BS 476:Part 20 & BS EN 1366-3.
 Material Safety Data Sheets
 Installation Instructions
 Product Certification
ORDERING
When ordering this product you will
need the following information:
PFC Corofil Intumescent Pillows friction fitted between
PFC Corofil Intumescent Pillows supported
services and firewall.
by mesh cage in service riser floor.
 Details of hole size
 Details of service penetrations
 Quantity required
Labels
A = PFC Corofil Intumescent Pillows
Please order from our technical
B = Basket of galvanised steel wire mesh 50mm x 50mm
sales office.
squares, wire diameter 2.5mm mesh basket mechanically
fixed to floor slab.
PFC Corofil
C = Wire mesh as above, overlapping basket mesh and tied
Units 3-4
together with steel wire
King George Trading Estate
Davis Road
PFC Corofil Intumescent Pillows forming cavity barrier
under raised access floor.
Chessington
Estimating Quantities
Surrey KT9 1TT
Pillow Size
Approximate Number
Specification
300mm x 50mm x 35mm
660 per m2 opening
Install PFC Corofil Intumescent Pillows to provide up to
300mm x 100mm x 35mm
330 per m2 opening
300mm x 150mm x 35mm
220 per m2 opening
Fax: + 44 (0) 208 391 2723
300mm x 200mm x 35mm
165 per m2 opening
Email: sales@pfc-corofil.com
4 hours fire protection where services pass through fire rated
walls and floors. Installation to be fully in accordance with
manufacturer’s instructions.
Tel: + 44 (0) 208 391 0533
www.pfc-corofil.com
SERVICE PENETRATIONS
Certificate number: FS453/04
P12 37A FIRESTOP MORTAR
PFC Corofil Firestop Compound
Application
Description
PFC Corofil Firestop Compound is used to provide a
Firestop Compound is a specially formulated gypsum
fire rated seal around service penetrations in fire rated
based mortar, which is mixed with water to be
walls
with
trowelled or poured around service penetrations.
BS 476:Part 22, PFC Corofil Firestop Compound
and
floors.
Tested
in
accordance
Plastic pipework must be protected with either PFC
provides up to 6 hours fire protection.
Corofil Firestop Collars or Intumescent Pipe Wraps
FIRE RATINGS
Tested to BS 476:Part 22
0
3hr
6hr
(see data sheets).
General benefits:
Fire Rating
 Smoke seal
In floors, PFC Corofil permanent shutter panel
 Good acoustic insulation
(50mm) is cut and friction fitted between services and
 Simple installation
the edges of the floor slab. Firestop Compound is then
 Load bearing seal
trowelled over the shutter to a depth of 25mm thick.
 Suitable to make good around most types of
This is allowed to harden. The Firestop Compound is
the required depth.
 Unaffected by humidity
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
 Maintenance free
In walls, Firestop Compound is mixed into a stiff
 No smoke emission
consistency for trowelling into smaller openings. In
larger openings, Firestop Compound can be cast into
Fire Rating
blocks which can be built into walls.
Thickness of Compound
1-2 Hours
75mm
3-6 Hours
100mm
Acoustic
Thickness of Compound
You can request from our technical
then mixed to a pouring grade and tops the seal up to
service penetrations
Fire Rating
TECHNICAL INFORMATION
Weighted Sound
Reduction Index (Rw)
Coverage
Thickness of Compound
Number of Bags per m²
75mm
3.15
100mm
4.2
150mm
6.3
These are approximate calculations based on 22kg
50mm
39dB
bags. The coverage does not take into account the
100mm
46dB
percentage of the hole filled with services.
150mm
51dB
Specification
Install PFC Corofil Firestop Compound to provide
1,2,3 or 4 hour fire rating to all service penetrations
through all fire rated walls and floors. Installation to be
fully in accordance with manufacturer’s instructions.
 Product Certification
SERVICE PENETRATIONS
PFC Corofil Firestop Compound
Load Bearing Fire Seals
Thickness of Compound
Load Bearing Area
Free of Services
75mm
500 x 500mm *
100mm
750 x 750mm *
The open area free of services: thickness of seal
ratios for non-reinforced seals given above, allow an
ample safety margin for normal foot traffic; e.g loads
of two men plus equipment with a combined weight of
up to 200kg. Firestop Compound sets in 30-45
minutes and is capable of accommodating foot traffic
in approximately 72 hours.
* As a further safety margin, we would recommend
PFC Corofil Firestop Compound poured onto permanent
mineral fibre shutter in floor.
that all floor seals with clear areas greater than in the
above table must be reinforced. Please contact our
technical department for details.
ORDERING
When ordering this product you will
need the following information:
 Size of opening
 Details of service penetrations
 Fire rating
 Quantity required
PFC Corofil Firestop Compound trowelled into wall.
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: +44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Intumescent Silicone Putty
Application
Description
PFC Corofil Intumescent Silicone Putty can be
PFC Corofil Intumescent Silicone Putty is a red,
used to form a fire resistant seal around pipe and
non-setting compound. It can be cut and moulded
cable penetrations. Tested in accordance with
between metal pipes and cable penetrations to
BS EN 1366-3, the putty can provide up to 4 hours
plug holes in compartment walls and floors.
FIRE RATINGS
Tested to BS EN 1366-3
0
2hr
4hr
fire protection.
PFC
Corofil
Intumescent
Silicone
Putty
is
Fire Rating
General benefits:
particularly useful in sealing cable bunches in trays

Easy to install
and electrical trunking. Due to its non-setting

Ideal for sealing around cables in electrical
nature it remains malleable, so it can easily be
trunking and cable trays in coated panels
removed and replaced to accommodate the

No maintenance
introduction and removal of future service runs.
sales office the following information:

No smoke emission
Easy to remove and reinstate for new
In a fire, the putty intumesces to fill small gaps
 Material Safety Data Sheets
services
between services.
 Installation Instructions

Specification
Fire Rating
Install PFC Corofil Intumescent Silicone Putty
PFC Corofil Intumescent Silicone Putty can
provide up to 4 hour fire protection in floors and
walls with metal pipes, steel electrical trunking and
cables at a depth of 79mm.
Corofil
Intumescent
You can request from our technical
ORDERING
around cable trays and internally within metal
electrical trunking. Installation to be fully in
accordance with manufacturer’s instructions.
When ordering this product you will
need the following information:
 Quantity required
Packaging
PFC
TECHNICAL INFORMATION
Silicone
Putty
is
Please order from our technical
sales office.
packaged in 1 kg tubs.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Intumescent Conduit
FIRE RATINGS
Application
Description
PFC Corofil Intumescent Conduit is designed to
Installation
provide a Firestop cable management system for
plasterboard, masonry or concrete to suit the
passing electrical and telecommunications cables
outside diameter of the conduit. For masonry and
through fire rated walls and floors. Tested in
concrete substrates, cut the conduit to suit the
accordance with BS EN:1366-3,
PFC Corofil
thickness of the wall/floor and simply push through
Intumescent Conduit will provide up to 4 hours fire
the hole. For plasterboard applications, cut the
protection.
conduit leaving 12.5mm exposed on both sides of
is simple.
Core
drill
a
hole
in
Intumescent
Conduit
allows
0
2hr
4hr
Fire Rating
TECHNICAL INFORMATION
the wall.
The
Tested to BS EN:1366-3
electrical
You can request from our technical
contractors to partially or completely fill the product
For larger holes fit conduit around cables or sleeve
or install and leave it empty ready for future cable
the existing PVC conduit and make good with PFC
installation. This is a truly ‘fit and forget' product.
Corofil Coated Panel (50mm thick) or PFC Corofil
 Material Safety Data Sheets
Firestop Compound (min 75mm thick).
 Installation Instructions
For a cold smoke seal, gun PFC Corofil Acoustic
ORDERING
Fire Rating
Intumescent
Conduit
Plasterboard
Partition
(130mm Wide)
100% cable fill
120 mins
Masonry
Concrete
Wall
Floor
120 mins
240 mins
Coated
Panel
sales office the following information:
Intumescent Sealant into the conduit to a depth of
Floors / Walls
10mm. In a fire, the conduit expands to form a
When ordering this product you will
120 mins
char to prevent the passage of fire and hot gases
need the following information:
along the cables.
50% cable fill
120 mins
120 mins
240 mins
120 mins
Empty *
120 mins
120 mins
240 mins
120 mins
* If conduit is empty, the end must be sealed with either
gaffer tape of PFC Corofil Acoustic Intumescent Sealant.
 Size of conduit
 Quantity required
Sizes
PFC Corofil Intumescent Conduit is available in
1200mm lengths in the following sizes:
Please order from our technical
sales office.
Specification
Outside Diameter
Internal Diameter
Wall Thickness
up to 4 hours fire protection where cables pass
20mm
16.4mm
1.8mm
Units 3-4
through fire rated walls and floors. Installation
25mm
21.2mm
1.9mm
King George Trading Estate
to be fully in accordance with manufacturer’s
32mm
27mm
2.5mm
Davis Road
Install PFC Corofil Intumescent Conduit to provide
instructions.
PFC Corofil
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Glass Cloth Luminaire Canopies
Application
Description
PFC Corofil Glass Cloth Luminaire Canopies are
Tests have shown that without the canopy in place, fire
designed specifically to stop the passage of smoke and
and smoke would penetrate through the recessed light
fire through a fire rated ceiling where recessed luminaires
fitting within seconds, spreading into the void or room
are fitted. Tested in accordance with BS 476:Parts 20 &
above, endangering both lives and property.
FIRE RATINGS
Tested to BS 476:Parts 20 & 23
0
23 Clause 5. Also meets the requirements of Class ‘O’
½ hr
1hr
materials.
Fire Rating
General benefits:

60 minute fire rating

Lightweight and self supporting

Easily fitted from above the ceiling

Resistant to heat and abrasion
You can request from our technical

Suitable for suspended ceilings and modular ceilings
sales office the following information:

Certificate approval
TECHNICAL INFORMATION
 Material Safety Data Sheets
PFC Corofil Glass Cloth Luminaire Canopy installed
Fire Rating
PFC Corofil Glass Cloth Luminaire Canopies will provide
60 minutes protection by completely containing the fire
 Installation Instructions
above recessed light in suspended ceiling.
ORDERING
and smoke within the cover, whilst at the same time
allowing the heat from the light fitting to dissipate through
the cover.
When ordering this product you will
need the following information:
Canopy Sizes
 Size of Glass Cloth Canopy
Length
Width
Height
300mm
300mm
150mm
600mm
300mm
150mm
600mm
600mm
150mm
1200mm
300mm
150mm
1200mm
600mm
150mm
 Quantity required
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Thermal Luminaire Covers
Application
Description
PFC Corofil Thermal Luminaire Covers are fire
The covers are available to suit all common
rated
fire
600mm x 600mm and 1200mm x 600 mm fixtures.
resistance of recessed luminaire or fluorescent
The covers are ready to install with no assembly
module fixtures and reinstate the performance of
required and can also be retrofitted into position
ceilings when penetrated by recessed lights.
due to their flexible and durable design. The
covers
designed
to
upgrade
the
insulative
nature
of
the
covers
also
FIRE RATINGS
Tested to BS476:Part 23:1987
0
½ hr
1hr
offers
General benefits:
significant thermal and acoustic benefits to the

Lightweight: 1.5-2.5kg
ceiling system.

Easily fitted from above and below

No clips, screws, drilling or additional support
Fire Rating
ORDERING
You can request from our technical
required
sales office the following information:
 Material Safety Data Sheets
Fire Rating
 Installation Instructions
Tested in accordance with BS 476:Part 23:1987,
PFC Corofil Thermal Luminaire Covers will provide
up to 60 minutes fire protection.
TECHNICAL INFORMATION
PFC Corofil Thermal Luminaire Cover installed above
suspended ceiling.
When ordering this product you will
need the following information:
 Size of cover
 Quantity required
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Intumescent Vent Duct Sleeves
Application
Description
PFC Corofil Intumescent Vent Duct Sleeves provide up to
The sleeves are ready to install providing a quick ad easy
2 hours fire resistance to rectangular and circular PVC
solution without the need for foams, mastic or sealant.
ventilation ducting penetrations.
The unique product will sleeve over the plastic vent duct
FIRE RATINGS
Tested to
BS 476:Part 20:1987
EN 1366-3:2009
and will provide fire protection from both sides of the
General benefits:
partition.

Labour saving

Suitable for 30, 60 and 120 minute walls
The pre-formed design does not require additional metal

No metal sleeving
sleeving when fitted in plasterboard partitions and can be
0
1hr
2hr
Fire Rating
simply cut to allow easy fitting even when ducts are fitted
The sleeves are particularly suitable for use in
tightly against the ceiling soffit. The sleeves are available
plasterboard partitions but can be used in blockwork
for PVC plastic vent duct sizes.
walls.
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
Fire Rating
Tested in accordance with BS 476:Part 20:1987 and EN
 Material Safety Data Sheets
1366-3:2009, PFC Corofil Intumescent Vent Duct Sleeves
 Installation Instructions
will provide up to 2 hours fire protection.
ORDERING
Sizes
PFC Corofil Intumescent Vent Duct Sleeves are available
in the following sizes:
When ordering this product you will
need the following information:
Width
Height
Length
110mm
54mm
180mm
204mm
60mm
180mm
 Size of sleeve
 Quantity required
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
PFC Corofil Intumescent Vent Duct Sleeves installed in
fire rated walls.
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Intumescent Fan & Vent Sleeves
Application
Description
PFC Corofil Intumescent Fan and Vent Sleeves have
PFC Corofil Intumescent Fan and Vent Sleeves are
been developed to firestop polymeric fans and vents
simply fitted onto the spigot of the fan or vent and friction
where
rated
fitted into the plasterboard ceiling. The intumescent
plasterboard ceilings, which protect the stability and
material expands in a fire situation to maintain the fire
structure of timber floors.
rating of the ceiling system.
This is a common problem in multi storey timber framed
This simple and cost effective solution can replace the
buildings, including flats, hotels, student accommodation
more costly fire dampers or the labour intensive boarding
and military barracks where mechanical extract ventilation
out of ventilation ducting.
they
have
penetrated
through
fire
FIRE RATINGS
Tested to BS 476:Part 20:1987
0
½
1hr
Fire Rating
TECHNICAL INFORMATION
system systems are required for en-suite bathrooms and
kitchens.
You can request from our technical
Tested
in
accordance
with
BS 476:Part
20:1987,
sales office the following information:
PFC Corofil Intumescent Fan and Vent Sleeves are
designed to maintain the fire rating of both 30 and 60
 Material Safety Data Sheets
minute floor/ceiling systems when penetrated by ceiling
 Installation Instructions
fans or vents.
ORDERING
General benefits:

Easy to fit, no screws or sealants

Lightweight

Can be fitted above or within the ceiling depth

Hidden from view once fitted


PFC Corofil Intumescent Fan and Vent Sleeve under
installation.
When ordering this product you will
need the following information:
Acts as a resilient layer, reducing structural sound
 Size of sleeve
transmission between fan or vent and ceiling
 Quantity required
Available in 80 and 100mm sizes
Please order from our technical
sales office.
Fire Rating
PFC Corofil Intumescent Fan and Vent Sleeves will
PFC Corofil
provide up 60 minutes fire resistance.
Units 3-4
The ceiling will need to be cut to the following diameters:
Sleeve
Outside
Reference
Diameter
80mm
110/80
110
110
100mm
130/102
130
130
Size of Spigot
Size of Hole
PFC Corofil Intumescent Fan and Vent Sleeve.
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
SERVICE PENETRATIONS
PFC Corofil Intumescent Cable Basket Sleeves
Application
Description
PFC Corofil Intumescent Cable Basket Sleeves are
The Cable Basket Sleeves are ready to install providing a
designed to provide a fire and acoustic seal to cable
quick and easy solution without the need for foams,
baskets or trays when penetrating fire rated and acoustic
sealants or pillows. The sleeves provide an effective fire
walls.
seal around both the cables and cable tray or basket.
General benefits:
The Cable Basket Sleeve is simply fitted around the cable

Labour saving
basket / tray and is located centrally within the wall. This

Cables can be added and removed

Full range of sizes

Dry system, no need for additional sealants
FIRE RATINGS
Tested to BS 476:Part 20:1987
0
Sealant (for gaps up to 10mm wide), plasterboard, mortar
or PFC Corofil Firestop Compound.
The Cable Basket Sleeves are available for all common
in
2hr
Fire Rating
can be made good with PFC Corofil Acoustic Intumescent
Fire Rating
Tested
1hr
basket or tray sizes from 50mm up to 450mm and have
accordance
with
BS 476:Part
20:1987,
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
been fire tested both with and without cables.
PFC Corofil Cable Basket Fire Sleeves will provide up to
 Material Safety Data Sheets
2 hours fire protection.
 Installation Instructions
Acoustic
ORDERING
Tested up to a Weighted Sound Reduction Index (Rw) of
50dB. Contact our technical sales office for further
When ordering this product you will
information.
need the following information:
Sizes
Internal Width
Internal Height
Length
324mm
64mm
180mm
478mm
64mm
180mm
 Size of sleeve
PFC Corofil Cable Basket Fire Sleeve installed in
 Quantity required
drywall.
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
PIPEWORK
Certificate number: FS453/07
P12 370A PIPE COLLAR CONCEALED INTUMESCENT
PFC Corofil Intumsecent Firestop Collars
Application
Description
PFC Corofil Intumescent Firestop Collars provide a
PFC Corofil Intumescent Firestop Collars consist of a
simple and effective method of firestopping plastic
powder coated steel sleeve containing a flexible
pipework where it passes through compartment walls
graphite based intumescent liner manufactured to suit
and
the pipework to be firestopped.
floors.
Tested
in
accordance
with
FIRE RATINGS
Tested to BS 476:Part 20 & EN 1366-3
0
2hr
4hr
BS 476:Part 20 and EN 1366-3, PFC Corofil Firestop
Collars will provide up to 4 hours fire protection.
Integral toggles are opened up and the collar is simply
Fire Rating
fitted around the plastic pipe. The toggles are closed
General benefits:
and the collar is pushed flush to the surface of the wall

Simple to install
or underside of floor. The collar is then securely

Water resistant
fastened to the structure by means of fire resistant

Maintenance free
fixings threaded through fixing tabs.

Available to suit pipe sizes ranging from 55mm to

250mm outer diameter
Annular gaps around the pipe of up to 15mm should
3rd Party Certificated
be filled with PFC Corofil Acoustic Intumescent
Sealant. For annular gaps greater than 15mm PFC
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
 Product Certification
Corofil Firestop Compound can be used. Under fire
Fire Rating
conditions the intumescent material swells filling the
Outside Diameter of Pipework
Fire Rating
55mm - 250mm
2 or 4 Hours
void left by the burnt out plastic.
ORDERING
When ordering this product you will
need the following information:
Suitable
for
sealing
PVC,
UPVC,
CPVC
Polypropylene, HDPE, MDPE, PE plastic pipes.
 Outside diameter of pipework
ABS plastic pipes can be sealed up to 55mm.
 Fire rating
Not suitable for ventilated pipe applications. Please
 Quantity required
consult our technical sales office for clarification.
Please order from our technical sales
office.
Specification
Install PFC Corofil Intumescent Firestop Collars to
PFC Corofil
provide up to 1, 2, 3 or 4 hours fire protection to all
Units 3-4
plastic pipework. Installation to be fully in accordance
with manufacturers instructions.
King George Trading Estate
PFC Corofil Intumescent Firestop Collars fixed to both
sides of wall.
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: +44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
PIPEWORK
Certificate number: FS453/06
P12 44A PIPE FIRE SLEEVES
PFC Corofil Intumescent Pipe Wraps
Application
Description
PFC Corofil Intumescent Pipe Wraps offer a
Pipe Wraps comprise layers of a graphite based
simple and more economic alternative to Firestop
intumescent sheet encapsulated in a polythene
collars for firestopping plastic pipework and
sheath. The product is manufactured to be
electrical trunking in walls and floors. Tested in
wrapped around the outside diameter of the
accordance with BS 476:Part 20 & BS EN 1366-3,
pipework or trunking and is secured by means of a
PFC Corofil Intumescent Pipe Wraps will provide
self-adhesive strip.
FIRE RATINGS
Tested to BS 476:Part 20 & EN 1366-3
0
2hr
4hr
Fire Rating
up to 4 hours fire protection.
The Intumescent Pipe Wrap is then positioned
TECHNICAL INFORMATION
General benefits:
within the compartment wall or floor so that the

Simple to install
edge of the product is left exposed at the face of

No mechanical fixings
the wall or soffit. The Pipe Wrap is then sealed into

Water resistant
the structure with PFC Corofil Firestop Compound.

Maintenance free
Under fire conditions, the intumescent material
 Material Safety Data Sheets
expands against the structure and fills the void left
 Installation Instructions
by the burnt out plastic. In walls, pipe wraps must
 Product Certification

Available to fit most electrical trunking sizes

Available to suit pipe sizes up to 160 mm O.D.

3 Party Certificated
rd
You can request from our technical
sales office the following information:
be fitted and built into both sides of the wall,
leaving the edge of the wrap exposed.
ORDERING
Fire Rating
When ordering this product you will
need the following information:
Outside Diameter of Pipework
Fire Rating
55mm
2 or 4 Hours
 Outside diameter of pipework
82mm
2 or 4 Hours
 Fire rating
110mm
2 or 4 Hours
160mm
2 or 4 Hours
 Quantity required
Please order from our technical
PFC
Corofil
Intumescent
Pipe
Wrap
sealed
into
sales office.
compartment wall with PFC Corofil Firestop Compound.
Specification
PFC Corofil
Install PFC Corofil Intumescent Pipe Wraps to
Units 3-4
provide up to 4 hours fire protection to all plastic
King George Trading Estate
pipework and electrical trunking where they pass
Davis Road
through fire rated walls and floors. Installation to
Chessington
be
Surrey KT9 1TT
fully
in
accordance
with
manufacturers
instructions.
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
PFC
Corofil
Intumescent
Pipe
Wrap
sealed
into
compartment floor with PFC Corofil Firestop Compound.
www.pfc-corofil.com
PIPEWORK
PFC Corofil Cast-In Device
Application
PFC Corofil Cast-In Device provides a fire rated
engineered solution to channel plastic pipes through
dedicated points in compartment floors, without the need
to fit firestop collars or wraps.
General benefits:

One step cast-in-installation

Ready to use

Easy to remove and replace pipe

Allows for pipe adjustments during installation

Economical in use owing to short installation time

Reduces trip hazard risk
Description
PFC Corofil Cast-In Device is manufactured from a high
expansion intumescent material (150mm depth x 8mm
FIRE RATINGS
thick) lining the internal diameter of a 160mm diameter
HDPE twin wall corrugated pipe. The unit has a standard
Tested to BS EN:1366-3
length of 250mm long with a steel fixing plate at its base
(190mm x 190mm) and a plastic/steel cap. The unit can
0
1hr
2hr
easily be tailor made to suit project requirements.
Fire Rating
TECHNICAL INFORMATION
You can request from our technical
Fire Rating
sales office the following information:
Tested in accordance with BS EN:1366-3, PFC Corofil
Cast-In Device will provide up to 2 hours fire protection
 Material Safety Data Sheets
with 110mm diameter PVC and HDPE plastic pipes.
 Installation Instructions
Minimum depth of concrete slab is 150mm for a 2 hour fire rating
(integrity/insulation) with 110mm diameter PVC and HDPE pipes.
ORDERING
When ordering this product you will
need the following information:
 Quantity required
Please order from our technical
sales office.
Mechanically fix the base plate to the top of the shuttering with snap
PFC Corofil
head nails and the height of the unit can easily be cut to the required
Units 3-4
height of the concrete slab with hand tools.
King George Trading Estate
The plumber can then push the pipe up through the underside of
the unit, which allows for a degree of realignment, unlike other
systems currently on the market.
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Description
Outside Diameter
160mm
Internal Diameter
122mm
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
PIPEWORK
P12 44A PIPE FIRE SLEEVES
PFC Corofil Insulated Fire Sleeves
Application
Description
For insulated pipes it is normally necessary to remove the
PFC Corofil Insulated Fire Sleeves are a unique combination
insulation at point of penetration to enable standard pipe
of mineral fibre and graphite intumescent that provide all the
collars to close plastic pipes. Standard pipe insulation will not
benefits of mineral wool’s thermal, noise and fire properties
provide an effective firestop as it will either shrink back, melt or
with an added intumescent effect.
FIRE RATINGS
Tested to BS 476:Part 20:1987
burn, however if this insulation is removed this can result in
condensation on cold pipes and loss of thermal performance
0
Fire
on hot pipes. PFC Corofil Insulated Fire Sleeves avoids this
1hr
2hr
PFC Corofil Insulated Fire Sleeves are intended for use on
problem by providing both fire stopping and thermal insulation.
copper, mild steel, polypropylene and PVC pipes. Tested in
Fire Rating
accordance with BS 476: Part 20: 1987, the sleeves provide
General benefits:
up to 2 hours fire protection.
TECHNICAL INFORMATION

Labour saving

Acoustic rated

No over sleeving required

Full range of sizes
The use of Insulated Fire Sleeves can considerably reduce the

Dry system, no need for additional sealants
noise emission from noisy pipework. For higher standards of
Acoustic
You can request from our technical
sales office the following information:
acoustic insulation please refer to our technical department.
Compatibility
Tested up to a Weighted Sound Reduction Indew (Rw) of
 Material Safety Data Sheets
PFC Corofil Insulated Fire Sleeves are compatible with most
49dB.
 Installation Instructions
materials with which it is likely to come into contact in normal
building and industrial applications. Precautions should be
ORDERING
Service Temperatures
taken when insulating austenitic stainless steel, regardless of
Insulated Fire Sleeves are used to firestop pipe work
insulation type.
operating
at
temperatures
between
0ºC
and
180ºC.
At low temperatures, care should be taken to maintain the
Biological
When ordering this product you will
need the following information:
vapour barrier.
The insulation offers no sustenance to vermin and does not
 Pipe diameter
encourage the growth of fungi, moulds or bacteria.
 Quantity required
Test Data
Please order from our technical
Pipe Wall
Range
Thickness Range
Floor *
22mm - 165mm
2.5mm - 14.2mm
12mm - 160mm
Polybutylene
PVC
Steel
Uninsulated
Cooper
Uninsulated
sales office.
Orientation & Construction Type
Pipe Size
Pipe Material
Wall *
Integrity
Insulation
M, LDC, HDC
PB & M
120 mins
0
2.5mm - 14.2mm
M, LDC, HDC
PB & M
120 mins
0
12mm - 28mm
2mm - 3.5mm
M, LDC, HDC
MW **, PB & M
120 mins
120 mins
55mm - 160mm
3mm - 4.2mm
M, LDC, HDC
MW **, PB & M
120 mins
120 mins ***
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
* Sleeve needs to protrude 25mm out of walls / floors and 50mm out of PFC Corofil Coated Panels
Fax: + 44 (0) 208 391 2723
** Up to 110mm diameter / *** 160mm diameter applications is limited to 90 mins
Email: sales@pfc-corofil.com
M = Masonry, LDC = Low Density Concrete, HDC = High Density Concrete, MW = Mineral Wool, PB = Plasterboard
www.pfc-corofil.com
PIPEWORK
PFC Corofil Metal Case Fire Sleeves
Application
PFC Corofil Metal Case Fire Sleeves have been tested in
accordance with BS EN:1366-3 Penetration seals in
concrete floors with High Density Polyethylene plastic
pipes for up to 2 hours fire protection.
containment in both plasterboard and block work walls for
Tested to BS EN:1366-3
up to a 2 hour fire rated seal. The Fire Sleeve is a
0
1hr
2hr
intumescent compound overlaid with a fire resistant
acoustic foam compression seal. The intumescent liner

Easy to fit

Suitable for core drilled holes

Allow thermal movement of pipe in floors

Available in sizes up to 200mm outside diameter
Fire Rating
and foam are water, moisture and lubricant resistant. The
pipe for PVC, HDPE and Polypropylene pipes
intumescent liner expands when exposed to heat and so
provides a fire barrier.
When used to seal plastic pipes it will fill the void left by
Stainless steel sleeve, resistant to long term
the collapsing pipe. Intumescent, expands up to 50 times
corrosion
whilst creating high pressure of a minimum of 30 bar
Foam gasket top and bottom forms cold smoke seal
compression strength. It will close a plastic pipe, which is

FIRE RATINGS
PFC Corofil Metal Case Firesleeves are suitable for fire
stainless steel sleeve lined with a high expansion
General benefits:

Description
collapsing due to fire.
Fire Rating
PFC Corofil Metal Case Fire Sleeves will provide up to 2
hours fire protection.
TECHNICAL INFORMATION
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
PFC Corofil Metal Case Fire Sleeves are simply clipped
around the pipe via a crimped edge. The fire resistant
ORDERING
foam seal at top and bottom form a cold smoke seal and
allow the pipe to be manoeuvred within the sleeve. In
Physical Dimensions
floors the bottom end of the sleeve must protrude 40mm
When ordering this product you will
Length
beneath the soffit level to enhance rapid thermal
need the following information:
80mm
205mm
transmission to the Intumescent layer and to allow
107mm
205mm
Building Control to ensure that a seal has been installed.
 Outside diameter of pipework
Make good between the sleeve and the concrete floor
 Quantity required
Pipe
Inner
Outer
Diameter
Diameter
Diameter
55mm
55mm
82mm
82mm
110mm
110mm
135mm
205mm
160mm
160mm
185mm
205mm
200mm
200mm
225mm
205mm
slab using PFC Corofil Firestop Compound (minimum
depth of 70mm).
Sizes
PFC Corofil Metal Fire Sleeves are available from 15mm
to 200mm diameter with larger sizes available on request.
Please order from our technical sales
office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
ELECTRICAL
PFC
Acoustic
Intumescent
Putty
Pads
PFCCorofil
Corofil
Intumescent
Putty
Pads
Application
Description
PFC Corofil Acoustic Intumescent Putty Pads have been
PFC Acoustic Intumescent Putty Pads are manufactured
developed to maintain the acoustic integrity and fire
from a red, nonsetting, silicone based intumescent
resistance of plasterboard partitions, where plastic
polymer.
electrical
socket
boxes
penetrate
them.
Installation is simple:
They also make a significant contribution to the reduction

Remove the face plate of the electrical socket box.
of air leakage in properties helping reduce energy costs

Mould the pre-formed putty pads into the back of the
and carbon emissions.
FIRE RATINGS
Tested to BS 476:Part 20:1987
0
2hr
Fire Rating
box and around the cables.

1hr
Simply replace and secure the face plate.
General benefits:
TECHNICAL INFORMATION

Provides fire protection
Under fire conditions the intumescent pad expands to fill

Reduces noise transfer
the void left by the burnt out electrical socket box,
You can request from our technical

Pre-cut cross shape ensures hassle free installation
preventing the spread of fire through the plasterboard
sales office the following information:

Low smoke emission
wall. The intumescent putty can also be used for

Maintenance free
upgrading the acoustic performance of partitions where
 Material Safety Data Sheets

Remains malleable
electrical sockets boxes have penetrated the wall
 Installation Instructions

Long service life
reducing room-to-room noise transfer.

Available for singe and double sockets
ORDERING
Fire Rating
When ordering this product you will
Tested in accordance with BS 476:Part 20:1987 and
need the following information:
EN 1366-3, PFC Corofil Acoustic Intumescent Putty Pads
provide up to 2 hours fire protection.
 Size
 Quantity required
Acoustic
Measurement of airborne sound insulation was made in
accordance with BS EN ISO 140-3:1995. Single number
Switch box before installation of Putty Pad.
Please order from our technical
sales office.
quantities were calculated in accordance with BS EN ISO
717-1:1997. The putty pads provide a Weighted Sound
PFC Corofil
Reduction Index (Rw) of up to 67dB.
Units 3-4
King George Trading Estate
Specification
Davis Road
PFC Corofil Acoustic Intumescent Putty Pads are
Chessington
available in two sizes to suit single and double gang
Surrey KT9 1TT
electrical boxes.
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Putty Pad installed inside switch box.
Email: sales@pfc-corofil.com
www.pfc-corofil.com
ELECTRICAL
PFC Corofil Fire & Acoustic Switch Box Inserts
Application
Description
PFC Corofil Fire & Acoustic Switch Box Inserts are a
The Switch Box Inserts are pre-formed and can be
cost effective and simple solution for protecting
installed
electrical switch and socket boxes when fitted in fire
adhesives. The simple mechanical fix ensures the
and acoustic rated walls. The intumescent material
insert will not be damaged or removed if the socket is
fully encases the inside of the socket box to provide
replaced or adjusted providing peace of mind for the
an acoustic seal but in a fire situation it expands and
installer. Offering significant labour and cost savings
seals the hole made for the sockets to limit fire
over plasterboard lining or putty pad solutions, the
spread.
Socket Box Inserts are available to suit both single
within
seconds
without
assembly
FIRE RATINGS
or
Tested to BS 476:Part 20&22:1987
0
1hr
2hr
Fire Rating
and double sockets.
TECHNICAL INFORMATION
General benefits:

Acoustic properties

Fits in seconds

No adhesives, no mess

Fits inside back boxes

Improved airtightness and energy saving
You can request from our technical
sales office the following information:
 Material Safety Data Sheets
 Installation Instructions
ORDERING
Fire Rating
Tested in accordance with BS 476:Part 20 & 22:1987
When ordering this product you will
for both integrity and insulation, PFC Corofil Fire &
need the following information:
Acoustic Switch Box Inserts will provide up to 2 hours
fire protection.
 Size
 Quantity required
Acoustic
Please order from our technical
Please consult our technical sales team for details.
sales office.
Sizes
PFC Corofil
Size
Depth of Box
Single
35mm
Double
35mm
Single
47mm
PFC Corofil Fire & Acoustic Switch Box Inserts can be
Davis Road
Double
47mm
fitted into the electrical metal or plastic back socket
Chessington
boxes.
Surrey KT9 1TT
Units 3-4
King George Trading Estate
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
ELECTRICAL
PFC Corofil Intumescent Downlight Covers
Application
Description
PFC Corofil Intumescent Downlight Covers are
The covers are simple to install and can be
designed to fire rate downlight fixtures and
retrofitted
reinstate
when
performance even if the downlight is removed and
penetrated by recessed downlights. Tested in
replaced. The covers are ventilated to allow heat
accordance with BS 476:Part 23:1987, PFC Corofil
to disperse from the light but in the event of a fire
Intumescent Downlight Covers will provide up to 2
the intumescent material expands to seal off the
hours fire protection.
ceiling cut-out and vent holes.
General benefits:
The covers are available in various sizes to suit a
the
performance
of
ceilings
FIRE RATINGS
into
position
providing
effective
Tested to BS 476:Part 23:1987
0
1hr
2hr
Fire Rating
ORDERING

No screws, drilling or support required
wide range of lighting products over and above
You can request from our technical

Easily fitted from above or below
those covered by fire rated downlights.
sales office the following information:

Ventilated to prevent heat build up

Use
Sizes
 Material Safety Data Sheets
PFC Corofil Downlight Covers are available in the
 Installation Instructions
with
suspended,
plasterboard
and
concrete ceilings
Fire Rating
following sizes:
Diameter
Height
150mm
150mm
PFC Corofil Downlight Covers will provide up to
200mm
200mm
2 hours fire protection.
250mm
250mm
370mm
210mm
Acoustic
Tested up to a Weighted Sound Reduction Index
(Rw) of 65dB. Contact our technical sales office for
further information.
TECHNICAL INFORMATION
When ordering this product you will
need the following information:
 Size
 Quantity required
Please order from our technical
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
ELECTRICAL
PFC Corofil Thermal Loft Covers
Application
Description
PFC Corofil Thermal Loft Covers have primarily been
The Loft Cover has been designed to meet both the
designed to prevent damp in loft spaces and to
new NHBC requirement for a vapour seal and the
conserve
with
requirement for continuous loft insulation, whilst still
BS 476:Part 20:1987, PFC Corofil Thermal Loft
maintaining an air space between the light fitting and
Covers will provide up to 1 hours fire protection.
the insulation as stipulated by many light fitting
energy.
Tested
in
accordance
FIRE RATINGS
Tested to BS 476:Part 20:1987
0
½
1hr
manufacturers.
Fire Rating
General benefits:

Non-combustible

Fire Resistant

Vapour Seal

Avoids overheating of downlights

Improved airtightness and energy saving
The fitting of recessed downlights into ceilings
penetrating a loft space can reduce the thermal
performance of the insulation by 50%. This is due to
TECHNICAL INFORMATION
the need to remove insulation from around the
downlights, resulting in large amounts of air leakage
You can request from our technical
and cold bridging. The fitting of PFC Corofil Thermal
sales office the following information:
Loft Covers allows the loft insulation to be continued
Fire Rating
directly over the cover and downlight and so fully
PFC Corofil Thermal Loft Covers will provide up to 60
reinstate the optimum performance of the loft
minutes fire protection.
insulation without gaps or interruption to work as
intended.
Acoustic
Please contact our technical sales team for details.
A typical recessed downlight allows the leakage of 20
cubic metres of air per hour which leads to huge heat
 Material Safety Data Sheets
 Installation Instructions
ORDERING
When ordering this product you will
need the following information:
losses when downlights are used in multiples. The
Thermal Performance
fitting of PFC Corofil Thermal Loft Covers reduces the
 Quantity required
The Loft Covers are simply placed over the light
air leakage down to insignificant levels and normal
fittings to eliminate thermal loss and condensation on
pressures so significantly reduces heat loss and
Please order from our technical
roof timbers.
meets air leakage targets.
sales office.
PFC Corofil
Units 3-4
King George Trading Estate
Davis Road
Chessington
Surrey KT9 1TT
Tel: + 44 (0) 208 391 0533
Fax: + 44 (0) 208 391 2723
Email: sales@pfc-corofil.com
www.pfc-corofil.com
PFC Corofil Thermal Loft Cover installed over downlight
with insulation above.
Fire I Thermal I Acoustic I Airtightness I
www.pfc-corofil.com
PFC COROFIL
Units 3&4 King George Trading Estate
Davis Road, Chessington, Surrey KT9 1TT
Tel: +44 (0)208 391 0533
Fax: +44 (0)208 391 2723
E-mail: sales@pfc-corofil.com
Download