SERIES PRECIFLOW PROPORTIONAL VALVES • Preciflow solenoid valves are designed to proportionally control the flow of air and inert gases by varying the electrical input signal to the coil • Low hysteresis (<5%), excellent repeatability (<1%), and high sensitivity (<0.1%) make these valves ideal for high precision flow control • Compact frictionless architecture saves valuable space in analytical and medical instrumentation • Valves do not require a minimum operating pressure, and are well-suited for vacuum operation • Power consumption as low as 1W to meet the most stringent instrument power requirements • Meets all relevant CE directives, and are RoHS compliant 202 2 1 I U 2/2 Normally Closed • Typical Applications Include: –– Gas Chromatography –– Mass Flow Controllers –– Dental Equipment –– Blood Pressure Monitoring Fluids* Temperature Range Seal Materials* Air, Oxygen, Inert Gas1 0 °C to 55 °C (32 °F to 131 °F) FKM/FFKM 1 Filtration: 5µm * Ensure that the compatibility of the fluids in contact with the materials is verified Materials in Contact with Fluid* Brass Seals FKM/FFKM Others Stainless Steel Port 1 Flow Body * Other materials on request Port 2 Input Signal Electrical Characteristics Coil Insulation Class F Connector Lead Wires 24 AWG; L = 500mm Electrical Safety Voltage Max. Operating Current V mA IEC 335 Electrical Enclosure Protection Standard Voltages IP50 6 6 VDC, 12 VDC, 24 VDC Voltage Regulation Flow Regulation Characteristics 0-6 VDC, 0-12 VDC, 0-24 VDC Pulse-width Modulation (>1000Hz) 12 Hysteresis typ. 5%; Repeatability typ. 1%; Sensitivity typ. 0.1% 24 Power Ratings Inrush ~ VA Holding ~ VA W Hot/Cold = W 170 1 420 2.5 85 - 210 - - Ambient Temperature Ranges 1 2.5 45 1 110 2.5 ºC (ºF) 0 to 55 (32 to 131) Specifications Orifice Size Flow Coefficient Pressure Differential bar (psi) Power Coil (W) Catalog Number mm (inches) Kv (m3/h) Cv min. max. = pad mount version 0.045 (0.0018) 0.00006 0.00007 -0.9 (-13) 10 (145) 1 R202A540L0XXXXX 0.07 (0.0023) 0.00012 0.00014 -0.9 (-13) 10 (145) 1 R202A541L0XXXXX 0.1 (0.0040) 0.0003 0.00035 -0.9 (-13) 10 (145) 1 R202A542L0XXXXX 0.2 (0.0079) 0.0012 0.00139 -0.9 (-13) 10 (145) 1 R202A543L0XXXXX 0.4 (0.0157) 0.0048 0.0055 -0.9 (-13) 10 (145) 2.5 R202A544L0XXXXX 0.6 (0.0236) 0.0096 0.0111 -0.9 (-13) 10 (145) 2.5 R202A545L0XXXXX 0.8 (0.0315) 0.018 0.0208 -0.9 (-13) 10 (145) 2.5 R202A546L0XXXXX Information subject to change without notice. For ordering information or regarding your local sales office visit www.ASCO.com. 1 SERIES 202 How to Order R202A540 L0 XXX XX Catalog Number (see table "Specifications") Voltage E7 = 6 VDC F3 = 12 VDC F1 = 24 VDC Connector Seal Materials V00= FKM 100= FFKM Ordering Example: R202A542L0V00F1 = 2-way NC (normally closed), orifice size 0.1mm, with lead wires L=500mm, FKM seal, 24 VDC Dimensions: mm (inches) Dimensional Drawing 15.5 (0.61) 12.7 (0.50) Port 1 Z 17.1 (0.67) 4.5 (0.18) 7.14 (0.28) 15 (0.59) 10.32 (0.41) REF 6.86 (0.27) 3.18 (0.12) 45 (1.77) 2 (0.08) 3.2 (0.126) 2x 3 (0.118) 2x 3.96 (0.16) REF 7.92 (0.31) 12.7 (0.50) 13.5 (0.53) 17.5 (0.69) 18.3 (0.72) DIN 912 - M3 2x Port 2 max. 13.5 (0.53) Z 5:1 Mounting Pattern 24 AWG 500 (19.7) Sealing (optional) Mounting Face (Proposal) 2.5 (0.098) 2x 0 0 5.9 (0.23) -0.1 0.8 (0.03) -0.05 2x M3 6 2x 4 (0.157) A 1 (0.039) A-A A 9 (0.354) Options • Digital control module Control D for DIN EN 50022 rail mounting Installation • The solenoid valves can be mounted in any position without affecting operation –– Used as a current regulator in open loop applications –– Used with an external sensor for closed-loop applications • Other materials and voltages available on request • Sealing FFKM: 514684-002, FKM: 514684-001 (minimum order quantity required) • Sub-Base with M5 connections and O-ring seals available on request 2 Information subject to change without notice. For ordering information or regarding your local sales office visit www.ASCO.com.