The Electrical Harmonizer–Automatic Voltage Regulator • Reduced Energy Cost, Consumption & Peak Power by up to 12% • Reduced Greenhouse Gas emissions •Increase life expectancy of electrical equipment •Measurement & Verification with an accuracy of ±4% 95% of the time About the Technology The Electrical Harmonizer–Automatic Voltage Regulator is an on-load automatic electronic tap changer with a high efficiency autotransformer that regulates voltage to the optimal level. There is an optimal minimum voltage level below the primary level (600V CA, 480V US, 400V EU) where lights, motors, etc, will operate comfortably with no effect on their practical performance. At 5% below the primary voltage (570V CA, 456V US, 380V EU) these loads are still within manufacturer’s specifications but will work with less waste heat, longer life, a lower carbon foot print and less energy. However, there are two factors preventing the power company from delivering the minimum optimal voltage to commercial and industrial facilities: line loss resistance and peak power. Power is distributed from a utility substation at a higher than necessary voltage level to ensure that the last building on the grid receives power above the minimal voltage level. Legend Power Systems provides a simple and effective technology solution that allows qualified commercial and industrial facilities to reduce their voltage to the optimal minimum in-spec level, without any worry about going too low when the power grid fluctuates. If a facility measured their incoming voltage and found that it was quite high, they could install a transformer that would step down the incoming voltage by a certain percentage. This “hard tap” transformer solution has been available for decades. However, if the grid power fluctuated down, the percentage reduction is “fixed” and the voltage can drop too low, causing a brown out. The Automatic Voltage Regulator continually monitors a facility’s incoming voltage level and automatically selects the correct tap setting on the autotransformer to ensure power is always entering the facility at an optimal level. If grid voltage levels drop below the minimum optimal, the system is immediately bypassed ensuring that the energy flow to your building is never negatively affected. The Problem – Line Loss Resistance & Peak Power Power Substation 871 kW 851 kW 830 kW 809 kW 788 kW CA US EU 630 V 504 V 420 V 615 V 492 V 410 V 600 V 480 V 400 V 585 V 468 V 390 V 570 V 456 V 380 V The Solution – Voltage Optimization with an Intelligent Transformer Power Substation 826 kW 795 kW 788 kW 788 kW 788 kW CA US EU 590 V 470 V 395 V 575 V 460 V 385 V 570 V 456 V 380 V 570 V 456 V 380 V 570 V 456 V 380 V Product Specification Sheet Product Number 400 500 600 700 800 900 1000 Maximum Primary Voltage Options 600, 480, 400* Frequency (Hz) Options 60, 50* Taps –2% –4% –6% Automatic Bypass (0%) Yes Tap Change MethodZero Crossing, On-Load, Fully Automatic, Processor Controlled, Electronic THD (v) on Tap Change <0.5% THD (current) on Tap Change <2.0% Efficiency 99.89% Ambient Temperature 0°C to 40°C – relative humidity 0 – 95% Cooling MethodConvection System Configuration 3 phase, 4 wire input/output Switching speed (msec) <100 Repetitive Full Range Tap Changing Interval (Sec) 30 Non Repetitive Tap Changing Interval (Sec) 10 Coil ConstructionForm Insulation Class 180 (H) Installation MethodsFloor Mount, Ceiling Mount, Seismic Frame, Split Module Maximum System Load Current Rating (Amps) 400* 500 600* 700* 800 900* Harmonizer Current Rating (Amps) 400, 300* 400 500 750 750 750 System / Breaker Current (Amps) 400 500 600 700 800 900 Reg coil Ω @ 25°C / 6% 0.105 0.094 0.084 0.049 0.049 0.049 % Impedance @ 115°C 0.16 0.16 0.17 0.18 0.18 0.18 Temp rise @ Full Load 38 38 39 42 42 42 1000* 750, 1000* 1000 0.032 0.22 43 Mechanical (Approximate – will vary with installation configuration) Weight (kg/lbs) Width (mm/in) Depth (mm/in) Height (mm/in) 355/783 813/32 660/26 915/36 355/783 813/32 660/26 915/36 380/838 813/32 660/26 915/36 604/1332 813/32 660/26 1219/48 604/1332 813/32 660/26 1219/48 604/1332 813/32 660/26 1219/48 604/1332, 702*/1548 813/32 660/26 1219/48 Harmonizer – AVR is classified as Industrial Control Equipment UL 508. Component certification is under UL 1561 US standards, and C22.2 No 47, Canadian standards. UL file number E228073. *Available in 400V 50Hz Single Line Diagram UTILITY PAD MOUNT TRANSFORMER MAIN SW. F DISCONNECT 800A 600/347V MAIN DISTRIBUTION PANEL RATED AT 800A CONT. UTILITY METERING M C/B HVAC & FANS LEGEND POWER HARMONIZER 800A 400A 800 AMP 200A AVR UTILITY FEED LIGHTING WAREHOUSE & WORKSHOP 208V DISTRIBUTION PANEL ELEVATOR SPARE LIGHTING 347 / 600 V (CA) 277 / 480 V (US) 230 / 400 V (EU) 600A 300 KVA 208/120V TRANSFORMER POWER LIFE SYSTEMS Other Installation Splice/cut-in locations are available TRANSFER SW legend power systems inc. www.legendpower.com electrical energy conservation EMERGENCY GEN