D & D0 L O W V O L T A G E F U S E S Y S T E M NH FUSE SYSTEM LOW VOLTAGE FUSE LINKS CIRCUIT PROTECTION SOLUTIONS Bussmann are one of the world’s leading suppliers of fuses and fusible protection systems. Provider of the world’s first truly NH FUSE SYSTEM LOW VOLTAGE FUSE LINKS global product line, each product is backed IEC CYLINDRICAL FUSE SYSTEM IEC BUSSBAR FUSE SYSTEM by an efficient world-wide distribution network service and unrivalled technical support. Bussmann circuit protection solutions comply with major international standards: BS, IEC, DIN and UL. IEC BUSBAR FUSE SYSTEM A comprehensive range of IEC CYLINDRICAL FUSE SYSTEM circuit HIGH VOLTAGE PRODUCTS HIGH SPEED FUSES protection solutions fused and non-fused. D&D0 - 2004 HIGH SPEED FUSES Cooper Bussmann Cooper (UK) Limited Burton-on-the-Wolds Leicestershire · LE12 5TH UK Telephone: 44 (0)1509 882 737 Facsimile : 44 (0)1509 882 786 http://www.bussmann.com HIGH VOLTAGE PRODUCTS Your Representative © Cooper Bussmann 2004. Printed July 2004 A Industries Company. D & D0 LOW VOLTAGE FUSE SYSTEM Contents Page D0 Industrial Fuse links 1 D0 Fuse Bases & Accessories 2 D01 Fuse Switch Disconnectors & Accessories 4 D02 Fuse Switch Disconnectors & Accessories 6 D Type Industrial Fuse Links 8 D Type Fuse Bases & Accessories 10 D&D0 Semiconductor Protection Fuse Links 15 D&D0 Fuseology 17 D&D0 Cross Reference Table 19 For more information visit our website at www.bussmann.com D & D0 LOW VOLTAGE FUSE SYSTEM D0 FUSE LINKS D0 fuse-links are used as the most reliable protection of electro installation, control and signal circuits against overload and short-circuit currents. The whole system D0 contains a complete range of fuse-links, standard ceramic and new plastic bases, fuse disconnectors and all necessary accessories. It is dimensioned for rated voltages 400 V a.c. resp. 250 V d.c. The system D0 is intended to be used in residential, business and similar buildings. When it is used in industrial plants, it is necessary to take into account the requirements of the standard IEC 60664-1 concerning the air insulation distances, creeping distances and mounting distances. Technical data: Rated voltage UN Rated current IN Breaking capacity at 1, 1 UN Fusing characteristics Standards Advantages of D0 are the following: - low power loss - cooler running - saving of storage and mounting place - constant quality control of parts and final products 400V; 250V AC DO1 2 - 16 A, DO2 20 - 63 A, D03 80 - 100 A 50 kA cosϕ = 0,1 8 kA T = 15 ms gG - gL IEC 60269, EN 60269, DIN VDE 0636, DIN EN 60269-1 (VDE 0636 Teil 10), DIN EN 60269-3 (VDE 0636 Teil 30), DIN VDE 0636-301, IEC 60269-1,3 EN 60269-1,3 SIST EN 60269 Fuse-Links D01 gG (gL) for fuse base E 14 Fuse-Links D02 gG (gL) colour part No. weight (g) packaging (pcs) dimension (ØA) 2 4 6 10 13 16 pink brown green red black grey 2NZ01 4NZ01 6NZ01 10NZ01 13NZ01 16NZ01 6 6 6 6 6 6 10/500 10/500 10/500 10/500 10/500 10/500 7.3 7.3 7.3 8.5 8.5 9.7 lN (A) colour part No. weight (g) packaging (pcs) dimension (ØA) 20 25 32 35 40 50 63 blue yellow black white black white copper 20NZ02 25NZ02 32NZ02 35NZ02 40NZ02 50NZ02 63NZ02 11 12 13 13 13 13 15 10/500 10/500 10/500 10/500 10/500 10/500 10/500 10.9 12.1 13.3 13.3 13.3 14.5 15.9 lN (A) colour part No. weight (g) packaging (pcs) dimension (ØA) 80 100 silver red 80NZ03 100NZ03 35 35 10 10 21.4 21.4 for fuse base E 18 Fuse-Links D03 gG (gL) 1 lN (A) for fuse base M 30 x 2 For more information visit our website at www.bussmann.com D & D0 LOW VOLTAGE FUSE SYSTEM D0 FUSE BASES Application The D0 fuse bases are designed for use in distribution boxes in domestic and public buildings. Total security against live parts is achieved by installing D0 fuse bases into the distribution boxes. Advantages - modular construction-module 9 mm - smaller weight and smaller height (66 mm) provide installation into the flush-mounting distribution boxes, the depth of which is 80 mm only - by the aid of gauge-piece key it is possible to change the gauge rings - the possibility of simple substitution of base D0 1 with D0 2. Technical data: Rated voltage UN Rated current IN Cross-section of connecting lead Standards 400 V DO1 16 A, DO2 63 A D01 1-4 mm 2 D02 1,5-25 mm 2 IEC 60269, EN 60269, DIN VDE 0636, SIST EN 60269 Single-pole fuse bases D0 type part No. D01N - K FRN01C D01V - K FN01C D02N - K FRN02C D02V - K FN02C D02N M6 - K FRN02C-A D02V M6 - K FRN02C-SA D01N FRN01-B D01V FRN01-SB D02N FRN02-D D02V FRN02-SD D02N M6 FRN02-E D02V M6 FRN02-SE IN(A) screw 16 16 63 63 63 63 16 16 63 63 63 63 with protection cover E14 E14 E18 E18 E18 E18 E14 E14 E18 E18 E18 E18 without protection cover x x x x x x click-on mounting screw mounting connections outlet supply X dimens. A (mm) 1.5 - 4 1.5 - 4 2.5 - 25 2.5 - 25 2.5 - 25 2.5 - 25 1.5 - 4 1.5 - 4 2.5 - 25 2.5 - 25 2.5 - 25 2.5 - 25 X X X X X x x x x x x cross-section of connecting lead (mm 2 ) X X X X X X 53 53 57 57 57 57 53 53 57 57 57 57 weight (g) packaging (pcs) 68 66 87 80 82 80 56 59 80 77 75 72 15/300 15/300 15/300 15/300 15/300 15/300 15/300 15/300 15/300 15/300 15/300 15/300 Three-pole fuse bases D0 type D01N/3 - K D01V/3 - K D02N/3 - K D02V/3 - K D02N/3 M6 - K D02V/3 M6 - K D01N/3 D01V/3 D02N/3 D02V/3 D02N/3 M6 D02V/3 M6 part No. TFRN01C TFN01C TFRN02C TFN02C TFRN02C-A TFRN02C-SA TFRN01-B TFRN01-SB TFRN02-D TFRN02-SD TFRN02-E TFRN02-SE IN(A) screw 16 16 63 63 63 63 16 16 63 63 63 63 E14 E14 E18 E18 E18 E18 E14 E14 E18 E18 E18 E18 with without protection protection cover cover x x x x x x click-on mounting screw mounting X X X X X X x x x x x x X X X X X X connections outlet cross-section of connecting lead supply dimens. A (mm) (mm 2 ) weight (g) packaging (pcs) 1.5 - 4 1.5 - 4 2.5 - 25 2.5 - 25 2.5 - 25 2.5 - 25 1.5 - 4 1.5 - 4 2.5 - 25 2.5 - 25 2.5 - 25 2.5 - 25 53 53 57 57 57 57 53 53 57 57 57 57 216 187 252 246 237 231 176 170 235 229 220 214 5/100 5/100 5/100 5/100 5/100 5/100 5/100 5/100 5/100 5/100 5/100 5/100 For more information visit our website at www.bussmann.com 2 D & D0 LOW VOLTAGE FUSE SYSTEM PROTECTION COVER FOR D0 FUSE BASES D01, D02 type for fuse base part No. weight (g) packaging (pcs) D01 D02 D01V, D01N D02V, D02N SFPCD01 SFPCD02 8 8 50/700 50/700 type for fuse base part No. weight (g) packaging (pcs) D01V/3, D01N/3 D02V/3, D02N/3 TFPCD01 TFPCD02 17 16 14/280 14/280 D01/3, D02/3 D01/3 D02/3 PLASTIC BASE PPD01 AND PPD02 1: PPD01 for fuse links D01, 2 - 16A 400V a.c. 2: PPD02 for fuse links D02, 20 - 63A 400V a.c. Standards IEC 60269, EN 60269, DIN, VDE 0636 Application They are mainly intended for distribution boxes in dwellings, office blocks and schools. Total security against live parts is achieved by installing D0 fuse bases into the distribution boxes type DIDO. Advantages - Connection at the input is possible with a clamp or with a screw, at the output it is possible to connect with a clamp - Mounting is on a standard DIN rail 35 mm (EN 50 022 and DIN EN 60715) - Temperature resistant material - Smaller weight of the product - Layout is adjusted for modern built in devices. Models: Single and three-pole version. type CAN NOT OPEN FILE PPD01-1 PPD01-3 PPD02-1 PPD02-3 number of poles IN (A) part No. weight (g) packaging (pcs) 1 3 1 3 16 16 63 63 DD01-1 DD01-3 DD02-1 DD02-3 70 220 86 270 15 3 15 3 GAUGE PIECES V D01 3 for fuse base E 14 lN (A) part No. 2 4 6 10 2GN01 4GN01 6GN01 10GN01 colour weight (g) 1001 1002 1003 1004 pink brown green red For more information visit our website at www.bussmann.com packaging (pcs) 1 50/500 1 50/500 1 50/500 1 50/500 dimension (ØA) (ØB) 7.9 7.9 7.9 9.1 12 12 12 12 D & D0 LOW VOLTAGE FUSE SYSTEM V D02 for fuse base E 18 lN (A) part No. colour weight (g) 2* 4* 6* 10* 16* 20 25 35 50 2GN02 4GN02 6GN02 10GN02 16GN02 20GN02 25GN02 35GN02 50GN02 pink brown green red grey blue yellow black white 1 1 1 1 1 1 1 1 1 packaging (pcs) 50/500 50/500 50/500 50/500 50/500 50/500 50/500 50/500 50/500 dimension (ØA) (ØB) 7.9 7.9 7.9 9.1 10.3 11.5 12.7 13.9 15.1 16.6 16.6 16.6 16.6 16.6 16.6 16.6 16.6 16.6 * for using fuse links D01 and fuse bases D02 Fuse carriers D0 type KN D01 KN D02 part No. screw weight (g) packaging (pcs) CN01 CN02 E 14 E 18 14 17 20/500 20/500 Special holder part No. DO-SFH Gauge piece key weight packaging (g) (pcs) 1 part No. 25/300 D0-GPK weight packaging (g) (pcs) 17 20/120 FUSE-SWITCH DISCONNECTOR VLD01 Fuse switch disconnector is a protection device with an exchangeable holder. This system enables the following protecting advantages, concerning the DO fuse: - Replacement of the fuse-link can be done with a mobile holder, without danger of direct contact to the live parts. - The device can be switched on without screwing, contact pressure is applied automatically by a spring. - Complete protection against touch by VBG 4. - In position 1 and 0, the fuse-link operation indicator is visible through a transparent window. Operating Principles of VLDO1 Exchangeable holder for fuse-links D01 (2A to 6A, 10A, 16A) has also the function of a switch lever, to switch on and off the VLDO1. The exchangeable holder can be replaced with an additional tool and it is used for mounting on the carrier rail according to EN 50 002 and DIN EN 60715 standards, in a way that the stopper is below. Technical data: Rated voltage UN Rated current IN Rated frequency fN Utilization category Mechanical life Electrical life Poles Standards Connection 230V, 230/400V, 400V a.c. 2- 6A, 10A, 16A 45-62 Hz AC22 10.000 cycles 5.000 cycles 1p, 1p+N, 2p, 3p, 3p+N VDE 0638, DIN 43880 25mm2 For more information visit our website at www.bussmann.com 4 D & D0 LOW VOLTAGE FUSE SYSTEM VLD01 1P lN (A) UN (V) part No. weight (g) packaging (pcs) 230/400 230/400 230/400 VLD01-1P6A VLD01-1P10A VLD01-1P16A 67 67 67 10/100 10/100 10/100 UN (V) part No. weight (g) packaging (pcs) 230 230 230 VLD01-1PN6A VLD01-1PN10A VLD01-1PN16A 135 135 135 5/50 5/50 5/50 UN (V) part No. weight (g) packaging (pcs) 400 400 400 VLD01-2P6A VLD01-2P10A VLD01-2P16A 135 135 135 5/50 5/50 5/50 UN (V) part No. weight (g) packaging (pcs) 400 400 400 VLD01-3P6A VLD01-3P10A VLD01-3P16A 203 203 203 3/30 3/30 3/30 UN (V) part No. weight (g) packaging (pcs) 400 400 400 VLD01-3PN6A VLD01-3PN10A VLD01-3PN16A 270 270 270 2/20 2/20 2/20 accessories part No. weight (g) packaging (pcs) holder/2-6A holder/10A holder/16A D012-6A D0110A D0116A 6 6 6 15/600 15/600 15/600 6 10 16 VLD01 1P+N lN (A) 6 10 16 VLD01 2P lN (A) 6 10 16 VLD01 3P lN (A) 6 10 16 VLD01 3P+N lN (A) 6 10 16 Accessories 5 For more information visit our website at www.bussmann.com D & D0 LOW VOLTAGE FUSE SYSTEM SWITCH - DISCONNECTOR - FUSE STVDO2 Switch disconnector Fuse is a device which combines the functions of the switch and of the fuse D0. The system enables the following advantages of protection in comparison with the fuse D0: - The changing of the fuse link without danger of direct touch of live parts. - Snap-on mounting on rail according to VOK 50022 and DIN EN 60715. - The complete protection against touch according to VBG 4. - The possibility of connecting supply from the upper or from the lower side. - It can be used as a main switch and tariff fuse in a single device. - Possibility of sealing in ON or OFF positions with or without fuse-link. Technical data: Standards Number of poles Rated voltage Rated breaking capacity Rated insulation voltage Rated impulse resistance voltage Category of use according to DIN VDE 0638 Category of use according to DIN E 60 947-3 Mechanical life Electrical life Temperature of environment Air humidity Degree of protection Connection clamps Possibility of sealing VDE 0638 EN 60 947-3, DIN VDE 0113, DIN VDE 0110 1p, 1p+N, 2p, 3p, 3p+N 230/400V a.c., 110V (2p) d.c. 50 kA 400V 8000V AC 22(63A), AC 23(35A), DC 22 (63A) 5.000 cycles 300 cycles -5 C to +40 C 90% IP 00 according to / nach DIN 40 050 Up to 35mm 2 (multiwire conductor) with screw +-/ in ON or OFF position STVD02 type number IN(A) of poles STV D02-1 STV D02-1N STV D02-2 STV D02-3 STV D02 -3N 1 1+N 2 3 3+N 63 63 63 63 63 part No. weight (g) packaging (pcs) STV-D02-1P STV-D02-1PN STV-D02-2P STV-D02-3P STV-D02-3PN 119 238 238 357 476 12 6 6 4 3 SWITCH DISCONNECTOR FUSE STVD02 ACCESSORIES Gauge pieces IN(A) part No. weight (g) packaging (pcs) 20 25 35 50 STVGP-DO2-20 STVGP-DO2-25 STVGP-DO2-35 STVGP-DO2-50 0.8 0.6 0.5 0.4 50 50 50 50 Their function is to limit the use of D0 fuse-links to user prescribed rated currents. The gauge piece can be inserted into the holder, when the fuse holder is extracted from the housing. Adapter part No. STV-ADP weight packaging (g) (pcs) 2.5 Its function is to allow the use of D01 fuse links (2-16A) with the fuse switch disconnector STV D02. 20 For more information visit our website at www.bussmann.com 6 D & D0 LOW VOLTAGE FUSE SYSTEM AUXILIARY SWITCH STV Auxiliary switch STV is intended to be mounted with switches of series STV. The width of apparatus is 9mm, other dimensions comply with STV series switches. Auxiliary switch STV serves for distant signalization of the state of contacts (on/off) of STV switch for circuit control. type PS STV - MD PS STV - 2M PS STV - 2D contacts 1 x b contacts, 1 x a contacts 2 x b contacts 2 x a contacts weight (g) part No. 50 50 50 STV-ADP-MD STV-ADP-2M STV-ADP-2D Technical data: Rated current IN Rated conditional short circuit current Standards a... make contact b... break contact 7 For more information visit our website at www.bussmann.com AC12 6A at 230V ~ DC12 1A at 110V = 1kA at 20A fuse link EN 62019 D & D0 LOW VOLTAGE FUSE SYSTEM D FUSE LINKS D type fuse-links are used to protect electric, signal and control I/t characteristics of type fuse-links comply with the following standards: IEC 60269/1, DIN VDE 0636/301 and CEE 16. CEE 16 standard regulates two types of characteristics: - quick characteristics, in ETI the so-called DZ and - time-lag, in ETI the so-called TDZ. Technical data: 500 V DI, DII 2 do 25 A, DIII 32 do 63 A DIV 80 do 100 A, DV 125 do 200 A 50 kA ~ cosϕ = 0,2 8kA T = 15ms gL - gG, TDZ, DZ C - VDE 0110 DIN EN 60269-1 (VDE 0636 Teil 10) DIN EN 60269-3 (VDE 0636 Teil 30) DIN VDE 0636-301 IEC 60269-1 IEC 60269-3 EN 60269-1 EN 60269-3 CEE 16 Rated voltage UN Rated current IN Breaking capacity at 1, 1UN VDE 0603/301 and IEC 60269-1 regulates the gG characteristics (protection in the whole range of the breaking capacity of the fuse). Because their breaking characteristics are completly in accordance with CEE 16 requirements for slow characteristics, they can also be labeled as TDZ. Fusing characteristics Insulating class Standards DI for fuse base E 16 IN(A) 2 4 6 10 16 20 25 colour part No. DZ pink brown green red grey blue yellow 2D16Q 4D16Q 6D16Q 10D16Q 16D16Q 20D16Q 25D16Q colour part No. DZ pink brown green red black grey blue yellow 2D27Q 4D27Q 6D27Q 10D27Q code No. weight gG, gL, TDZ (g) 2D16 4D16 6D16 10D16 16D16 20D16 25D16 12 12 12 13 14 15 16 packaging (pcs) 20/500 20/500 20/500 20/500 20/500 20/500 20/500 dimension ØA ØB 13.2 13.2 13.2 13.2 13.2 13.2 13.2 6 6 6 8 10 12 14 DII for fuse base E 27 IN(A) 2 4 6 10 13 16 20 25 16D27Q 20D27Q 25D27Q code No. weight gG, gL, TDZ (g) 2D27 4D27 6D27 10D27 13D27 16D27 20D27 25D27 27 27 27 27 27 28 29 30 packaging (pcs) 5/500 5/500 5/500 5/500 5/500 5/500 5/500 5/500 dimension ØA ØB 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 6 6 6 8 8 10 12 14 DIII for fuse base E 33 IN(A) colour 32 35 40 50 63 black black black white copper part No. DZ 35D33Q 50D33Q 63D33Q code No. weight gG, gL, TDZ (g) 32D33 35D33 40D33 50D33 63D33 48 48 48 49 52 packaging (pcs) 5/500 5/500 5/500 5/500 5/500 For more information visit our website at www.bussmann.com dimension ØA ØB 27 27 27 27 27 16 16 16 18 20 8 D & D0 LOW VOLTAGE FUSE SYSTEM DIV for fuse base R1 1/4" IN(A) 80 100 colour part No. DZ silver red 80D125Q 100D125Q code No. weight gG, gL, TDZ (g) 80D125 100D125 105 110 packaging (pcs) 10/100 10/100 dimension ØA ØB 33 33 5 7 DV for fuse base R 2" IN(A) 125 160 200 colour part No. DZ yellow copper blue 125D200Q* 160D200Q* 200D200Q* code No. weight gG, gL, TDZ (g) 125D200* 160D200* 200D200* 185 210 215 packaging (pcs) 10/60 10/60 10/60 dimension ØA ØB 46 46 46 5 7 9 * special order GAUGE PIECES VD II for fuse base E 27 IN(A) 2 4 6 10 16 20 25 colour pink brown green red grey blue yellow part No. 2GD27 4GD27 6GD27 10GD27 16GD27 20GD27 25GD27 weight (g) packaging (pcs) 13 13 13 11 11 11 11 25/1500 25/1500 25/1500 25/1500 25/1500 25/1500 25/1500 weight (g) packaging (pcs) 19 18 16 25/850 25/850 25/850 A dimension B C D 3/16" 6.5 17 3/16" 6.5 17 3/16" 6.5 17 3/16" 8.5 17 3/16" 10.5 17 3/16" 12.5 17 3/16" 14.5 17 24 24 24 24 24 24 24 VD III for fuse base E33 IN(A) 35 50 63 9 colour black white copper part No. 35GD33 50GD33 63GD33 A dimension B C D 3/16" 16.5 17 30 3/16" 18.5 17 30 3/16" 20.5 17 30 For more information visit our website at www.bussmann.com D & D0 LOW VOLTAGE FUSE SYSTEM D TYPE FUSE BASES Application The fuse bases type D are made to be incorporated into distribution boxes for individual applications, in industrial and public buildings. The bases most up-to-date design are EZN for mounting on rails (according to EN 50022 and DIN EN 60715) and bases EZR type, because they can be directly fastened on the EZR-busbar. Technical data: Rated voltage UN Rated current IN Insulating class Cross-section of connecting lead Standards, publications 500 V DII 25 A, DIII 63 A po VDE 0110 C DII 1 to 10 mm2 DIII 2,5 to 25 mm2 IEC 60269, EN 60269, DIN VDE 0636 SINGLE-POLE FUSE BASES EZ type HVB IN(A) EZ EZ part No. screw weight (g) packaging (pcs) A B C 25 63 SFD27 SFD33 E 27 E 33 122 175 36/288 15/180 41 45 47 56 36 45 IN(A) part No. screw weight (g) packaging (pcs) A B C 26 31 50 58 53 64 dimension D E F G 35 36 13 14 46 58 dimension D E F G M M 46 58 20 20 TZ type TZ TZ 25 63 SFD27-TZ SFD33-TZ E 27 E 33 185 368 24/192 10/100 13.5 16 14 18 IN(A) part No. screw weight (g) packaging (pcs) A B C dimension D E F G I 200 202 300 302 10/200 10/180 6/60 6/60 56 56 56 56 80 80 90 90 41 41 52 52 33 33 41 41 20 20 28 28 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 UZ, UZN type UZ UZN UZ UZN 25 25 63 63 SFD27-UZ SFD27-UZN SFD33-UZ SFD33-UZN E 27 E 27 E 33 E 33 82 82 82 82 * UZ - For mounting with screws * UZN - For mounting on rail For more information visit our website at www.bussmann.com 10 D & D0 LOW VOLTAGE FUSE SYSTEM EZR type EZR EZR IN(A) 25 63 part No. screw SFD27-EZR SFD33-EZR weight (g) packaging (pcs) 97 132 15/195 15/180 E 27 E 33 A dimension B C D 42 46 45 35 47 58 48.5 38 Busbar for fuse base EZR type IN(A) EZR EZR 25 63 part No. screw SFD27-BB SFD33-BB weight (g) packaging (pcs) 380 380 50 50 E 27 E 33 A dimension B C D E F 1000 32 52 3 16 3/16" 1000 38 62 3 16 3/16" Terminals for neutral terminals and busbars ERZ part No. for cross section weight (mm 2 ) (g) SFD27-NT SFD33-NT 16 35 9 21 packaging (pcs) 100/2200 100/2200 A dimension B C D E 25 12.5 3.5 17 7.3 28 12.5 6.5 21.5 12.6 EZN, EZV type EZN 25® EZN 63® EZN 63-M6® EZV 25 EZV 63 EZV 63-M6 EZN 25-ZP* EZN 63-ZP* EZV 25-ZP* EZV 63-ZP* IN(A) 25 63 63 25 63 63 25 63 25 63 part No. SFRD27 SFRD33 SFD33-EZN-M6 SFD27-EZV SFD33-EZV SFD33-EZV-M6 SFD27-EZN-ZP SFD33-EZN-ZP SFD27-EZV-ZP SFD33-EZV-ZP screw E27 E33 E33 E27 E33 E33 E27 E33 E27 E33 weight (g) packaging (pcs) A B dimension C D 104 148 148 102 146 146 120 163 112 153 15/195 15/180 15/180 15/195 15/180 15/180 10/130 10/120 10/130 10/120 41 43 43 41 43 43 41 43 41 43 39 47 47 39 47 47 39 47 39 47 44 44 44 44 44 44 44 44 44 44 * EZV - For mounting with screws * EZN - For mounting on rail 11 For more information visit our website at www.bussmann.com 47 47 47 47 47 47 47 47 47 47 E F 60 56 56 60 56 56 60 56 60 56 62 79 79 62 79 79 62 79 62 79 D & D0 LOW VOLTAGE FUSE SYSTEM Protection cover for fuse bases EZN and EZV type IN(A) EZN, EZV EZN, EZV 25 63 part No. SFPRD27 SFPRD33 screw E 27 E 33 weight (g) packaging (pcs) A 16 12 30/390 30/360 40 49 dimension B C 24 21 10.8 9 D 80 80 D Comfort type part No. weight (g) packaging (pcs) DII comfort SFD27-CFT 137 3/105 Technical data: Rated voltage UN Rated current IN For fuse-links type DII Gauge pieces VDII 500V 25 A acc. to IEC/EN 60269-3 acc. to IEC/EN 60269-3 Cross section of connecting leads Screws Mounting possibilities: 1.5 - 25 mm with ±head - with screws - mounting on the rail EN 50022 and EN60715 2 D TYPE THREE-POLE FUSE BASES EZN/3, EZV/3 - Delta type EZN 25/3 EZV 25/3 EZN 63/3 EZV 63/3 IN(A) 25 25 63 63 part No. TFD27-EZN TFD27-EZV TFD33-EZN TFD33-EZV weight (g) packaging (pcs) A B C 410 400 590 580 8 8 8 8 106 106 127 127 106 106 130 130 48 48 54 54 dimension D E / 32 / 32 For more information visit our website at www.bussmann.com / 5.2 / 5.2 F G H 45 45 45 45 52 52 52 52 86 86 85 85 12 D & D0 LOW VOLTAGE FUSE SYSTEM EZN/3, EZV/3 - Linear type EZN 25/3 EZV 25/3 EZN 63/3 EZV 63/3 IN(A) 25 25 63 63 part No. screw TFRD27 TFD27 TFRD33 TFD33 E27 E27 E33 E33 weight packaging (pcs) A B C 4/60 4/60 6/42 6/42 41 41 43 43 121 121 148 148 44 44 44 44 352 346 488 484 dimension D E 47 47 47 47 60 60 56 56 F ØG H 30 30 32 32 4.3 4.3 4.3 4.3 50 50 62 62 Protection cover for fuse bases EZN/3 and EZV/3 type part No. EZN, EZV 25/3 EZN, EZV 63/3 weight (g) packaging (pcs) A 40 40 12/120 12/120 121 148 weight (g) packaging (pcs) A 35 59 50/600 30/360 E E TFPCD27 TFPCD33 dimension B C 24 21 D 10.8 9 80 80 dimension B C D Fuse Carriers type IN(A) K DII K DIII 25 63 part No. screw CD27 CD33 E27 E33 44 44 12 12 34 43 Fuse bases for Overhead Lines type FZ FZ 13 IN(A) 25 63 part No. SFD27-OHL SFD33-OHL weight (g) packaging (pcs) ØA B ØC dimension D E F ØG H 750 1050 1/22 1/16 61 70 14 21 104 114 118 120 50 58 7 7 20 21 For more information visit our website at www.bussmann.com 90 130 D & D0 LOW VOLTAGE FUSE SYSTEM Amoured Fuse Bases type T 25/3N T 63/3N T 25/3V T 63/3V part No. SFD27-ARM3N SFD33-ARM3N SFD27-ARM3V SFD33-ARM3V weight (g) packaging (pcs) A B C D 460 660 450 650 4 4 4 4 106 127 106 127 106 130 106 130 48 54 48 54 / / 32 32 dimension E F / / 5.2 5.2 For more information visit our website at www.bussmann.com 45 45 45 45 G H I 52 52 52 52 86 85 86 85 97 97 97 97 14 D & D0 LOW VOLTAGE FUSE SYSTEM Fuse-link D 01 ULTRA-QUICK® for base E14 IN(A) part No. colour 2 4 6 10 16 2NZ01R 4NZ01R 6NZ01R 10NZ01R 16NZ01R pink brown green red grey IN(A) part No. colour 20 25 35 50 63 20NZ02R 25NZ02R 35NZ02R 50NZ02R 63NZ02R blue brown black white copper weight packaging dimension (g) (pcs) ØD 6 6 6 6 6 10/500 10/500 10/500 10/500 10/500 7.3 7.3 7.3 8.5 9.7 Fuse-link D 02 ULTRA-QUICK® for base E18 11 12 13 13 15 10/500 10/500 10/500 10/500 10/500 10.9 12.1 13.3 14.5 15.9 | 2 * values D0 ULTRA-QUICK® Technical data: Fuse-link Rated voltage UN Rated current IN Breaking Capacity I1 Fusing characteristic weight packaging dimension (g) (pcs) ØD D 01 / D 02 ULTRA QUICK 400 V ~ / 250 V 2 - 63 A 50 kA ~ / 8 kA gR Rated Melting current (A) integral (A2*s) Total integral (A2*s) at 100 V at 200 V at 400 V 2.3 4.7 7 25 70 120 160 250 550 800 4 8 12 40 100 180 280 450 850 1200 6.3 13 20 65 200 275 480 1000 1800 2500 1 2 5 12 35 55 85 180 250 550 2 4 6 10 16 20 25 35 50 63 Fuse-link D I ULTRA-QUICK® for base E16 IN(A) part No. colour 2 4 6 10 16 20 25 2D16R 4D16R 6D16R 10D16R 16D16R 20D16R 25D16R pink brown green red grey blue yellow IN(A) part No. colour 2 4 6 10 16 20 25 30 2D27R 4D27R 6D27R 10D27R 16D27R 20D27R 25D27R 30D27R pink brown green red grey blue yellow black weight packaging dimension (pcs) (g) ØB 12 12 12 13 14 15 16 20/500 20/500 20/500 20/500 20/500 20/500 20/500 6 6 6 8 10 12 14 Fuse-link D II ULTRA-QUICK® for base E27 15 For more information visit our website at www.bussmann.com weight packaging dimension (g) (pcs) ØB 27 27 27 27 28 29 30 30 5/500 5/500 5/500 5/500 5/500 5/500 5/500 5/500 6 6 6 8 10 12 14 14 D & D0 LOW VOLTAGE FUSE SYSTEM Fuse-link D III ULTRA-QUICK® for base E33 IN(A) part No. colour 35 50 63 35D33R 50D33R 63D33R black white copper IN(A) part No. colour 80 100 80D125R 100D125R silver red IN(A) part No. colour 125 160 200 125D200R 160D200R 200D200R yellow copper blue weight packaging dimension (g) (pcs) ØB 48 49 52 5/500 5/500 5/500 16 18 20 Fuse-link D IV ULTRA-QUICK® for base R1 1/4” weight packaging dimension (g) (pcs) ØB 105 110 10/100 10/100 5 7 Fuse-link D V ULTRA-QUICK® for base R 2” | 2 * values D ULTRA-QUICK® Rated Melting current (A) integral (A2*s) 2 4 6 10 16 20 25 30 35 50 63 80 100 125 160 200 0.7 1.8 4 8 16.2 35.8 48.9 85 135 340 530 980 1950 3100 10000 17000 weight packaging dimension (g) (pcs) ØB 185 210 215 10/60 10/60 10/60 5 7 9 Technical data: Max Total integral (A2*s) at 125 V at 250 V at 500 V 1.8 4.1 6 12.5 34 67 85 120 220 600 850 1480 3000 4300 12000 22000 3.5 6 10 23 40 85 116 170 300 780 1115 2110 4200 6000 18000 31000 5.8 11 18 40 60 139 205 310 539 1250 1890 4200 8450 16000 24000 40000 Fuse-link Rated voltage UN Rated current IN Breaking Capacity I1 Fusing characteristic DI, D II, D III, D IV, D V, ULTRA QUICK® 500 V ~ / 315 V 2 - 200 A 50 kA ~ / 8 kA gR For more information visit our website at www.bussmann.com 16 D & D0 LOW VOLTAGE FUSE SYSTEM D&D0 FUSE LINKS Description: Fuse-links are the oldest protective devices in the electrical industry. The protection by fuses is based on the principle a piece of wire melting at the point of defect of an electric circuit. For this purpose a sufficient amount of energy is necessary, which is called the Joule integral I 2 t. In order to adapt the fuse-links to specific protection requirements, various time current characteristics have been developed. A time current characteristic is a graphical representation of the melting time as a function of the overload current. The type of fuse is chosen based on the operational range of the fuse and the type of object under protection. Marks Fuse marking consists of two letters where the first letter denotes the function class and the second the type of facility under protection. Example: gG; g: protects a facility across the entire current axis; G: the facility under protection is electrical installation. Function class of fuses It determines the range on the current axis for which a fuse-link is capable of breaking a circuit. Function class g The entire range of operation of a fuse. Fuse-links continuously conduct rated currents and in case of a defect in the circuit they break all currents from the lowest melting current up to the highest breaking capacity (protection against overload and short circuits). Function class a These fuses provide limited range of protection. Fuse-links conduct continuously the rated currents and in case of a defect in the circuit they break all currents from a multiple of rated current up to the breaking current (protection against short circuits). Facilities under protection L: cables and mains B: mining equipment M: switching devices R: semiconductors T: transformers The types of fuse-links used for protection of the specified objects gG: total range of protection -cable and mains aM: partial range of protection -switching devices aR: partial range of protection – semiconductors gR: total range of protection – semiconductors gB: total range of protection -mining equipment gTr: total range of protection -transformers 17 Semiconductors in rectifiers require quick fuse-links of type aR and gR for protection. ULTRA-QUICK fuse-links comply with the following regulations: VDE 0636/23, VDE 0636/33, IEC 60269, DIN 57636, DIN 43620, DIN43653, DIN 49522. The requirements with which fuse-links for protection of semiconductors must comply are: high breaking capacity and quick action high current limitation low watts loss they should not be subject to ageing ULTRA QUICK fuse-links provide optimum protection of semiconductors, being used for special purposes: A: Ipol ≤ INtv The current passing through the semiconductor must be smaller or the same as the rated current of the fuse-link. Here you have to consider special ways of load (periodical, non-periodical, uniform, non-uniform) and other influences (thermical influences, cooling ). B: Upol ≤ UNtv The operating voltage on the semiconductor must be smaller or the same as the rated voltage of the fuse-link. In case of doubt the rated voltage of the semiconductor element to be protected can be used as a guideline. C: ƒi2 pol dt > ƒi2 Ntv dt The total Joule-integral of the chosen fuse-link I 2 dt must be lower than the limit integral of the semiconductor. If this data is not directly stated, it can be calculated from the data for the maximum permissible surge forward current for the duration of one-half period (10ms )-ITSM in the following way: D: Ik < Iltv The highest possible surge forward current of the short circuit which can appear in a circuit must be lower than the rated breaking capacity of the fuse-link. E: URRM > UL UDRM > UL The switching voltage (arc voltage ) of the fuse-link must be lower than the repetitive peak voltage of the semiconductor in the negative or positive direction. For more information visit our website at www.bussmann.com D & D0 LOW VOLTAGE FUSE SYSTEM D&D0 CROSS REFERENCE TABLE Size Class D01 D02 D03 DI / E16 D01 DII / E27 DIII / E33 DIV / R 1 1/4” DIV / R 2” Size Class DI / E16 DII / E27 DIII / E33 DIV / R 1 1/4” DV / R 2” Fast Acting Rating Bussmann 2 4 6 10 13 16 20 25 32 35 40 50 63 80 100 2 4 6 10 16 20 25 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 2NZ01 4NZ01 6NZ01 10NZ01 13NZ01 16NZ01 20NZ02 25NZ02 32NZ02 35NZ02 40NZ02 50NZ02 63NZ02 80NZ02 100NZ02 2D16 4D16 6D16 10D16 16D16 20D16 25D16 2D27 4D27 6D27 10D27 16D27 20D27 25D27 32D33 35D33 40D33 50D33 63D33 80D125 100D125 125D200 160D200 200D200 Rating Bussmann 2 4 6 10 16 20 25 2 4 6 10 16 20 25 35 50 63 80 100 125 160 200 2D16Q 4D16Q 6D16Q 10D16Q 16D16Q 20D16Q 25D16Q 2D27Q 4D27Q 6D27Q 10D27Q 16D27Q 20D27Q 25D27Q 35D33Q 50D33Q 63D33Q 80D125Q 100D125Q 125D200Q 160D200Q 200D200Q Ferraz Shawmut ETI M Schneider Siemens SIBA Weber Bals 1700.002 1700.004 1700.006 1700.01 1700.013 1700.016 1701.02 1701.025 1701.032 1701.035 1701.05 1701.063 1702.08 1702.1 594.0027 594.0047 594.0067 594.0107 594.0167 594.0207 594.0257 597.0027 597.0047 597.0067 597.0107 597.0167 597.0207 597.0257 598.0327 598.0357 598.0507 598.0637 598.0807 595.1007 595.1257 596.1607 596.2007 2211001 2211002 2211003 2211004 2211005 2212001 2212002 2212006 2212003 2212007 2212004 2212005 2213001 2213002 2311401 2311402 2311403 2311404 2311405 2311406 2311407 2312401 2312402 2312403 2312404 2312405 2312406 2312407 2313404 2313401 2313405 2313402 2313403 2314401 2314402 2315401 2315402 2315403 0810 0811 0812 0813 081301 0814 0815 0816 0817 0818 0818 0819 0820 0821 0207 0208 0209 0210 0211 0212 0213 028001 028101 028201 028301 028501 028601 028701 0288 0289 0290 0268 0269 0270 0271 0272 5SE2 202 5SE2 204 5SE2 206 5SE2 210 5SE2 216 5SE2 220 5SE2 225 5SE2 235 5SE2 250 5SE2 263 5SA2 11 5SA2 21 5SA2 31 5SA2 51 5SA2 61 5SA2 71 5SA2 81 5SB2 11 5SB2 21 5SB2 31 5SB2 51 5SB2 61 5SB2 71 5SB2 81 5SB4 11 5SB4 21 5SB4 31 5SC2 11 5SC2 21 - 10 027 04 2A 10 027 04 4A 10 027 04 6A 10 027 04 10A 10 027 04 16A 10 028 04 20A 10 028 04 25A 10 028 04 35A 10 028 04 50A 10 028 04 63A 10 029 04 80A 10 029 04 100A 10 002 04 2A 10 002 04 4A 10 002 04 6A 10 002 04 10A 10 002 04 16A 10 002 04 20A 10 002 04 25A 10 005 04 2A 10 005 04 4A 10 005 04 6A 10 005 04 10A 10 005 04 16A 10 005 04 20A 10 005 04 25A 10 007 04 35A 10 007 04 50A 10 007 04 63A 10 009 04 80A 10 009 04 100A 10 010 04 125A 10 010 04 160A 10 010 04 200A 8 111 100 281 8 111 100 481 8 111 100 681 8 111 101 081 8 111 101 681 8 111 202 081 8 111 202 581 8 111 203 581 8 111 205 081 8 111 206 381 2 111 308 081 2 111 310 081 2 118 800 201 2 118 800 401 2 118 800 601 2 118 801 001 2 118 801 601 2 118 802 002 2 118 802 501 8 115 200 231 8 115 200 431 8 115 200 631 8 115 201 031 8 115 201 631 8 115 202 031 8 115 202 531 8 115 303 501 8 115 305 001 8 115 306 301 - 910 911 912 913 914 915 916 917 918 919 927 928 929 9210 9211 9212 9213 9214 9215 9216 9217 9218 9219 9220 9221 9222 9223 - Ferraz Shawmut ETI M Schneider Siemens SIBA Weber Bals 594.002 594.004 594.006 594.01 594.016 594.02 594.025 597.002 597.004 597.006 597.01 597.016 597.02 597.025 598.035 598.05 598.063 - 2312101 2312102 2312103 2312104 2312105 2312106 2312107 2311101 2311102 2311103 2311104 2311105 2311106 2311107 2313101 2313102 2313203 2314101 2314102 2315101 2315102 2315103 0200 0201 0202 0203 0204 0205 0206 022001 022101 022201 022301 022501 022601 022701 0228 0229 0230 0231 0232 0235 0236 0237 5SA1 11 5SA1 21 5SA1 31 5SA1 51 5SA1 61 5SA1 71 5SA1 81 5SB1 11 5SB1 21 5SB1 31 5SB1 51 5SB1 61 5SB1 71 5SB1 81 5SB3 11 5SB3 21 5SB3 31 5SC1 11 5SC1 21 - 10 002 01 2A 10 002 01 4A 10 002 01 6A 10 002 01 10A 10 002 01 16A 10 002 01 20A 10 002 01 25A - 2 114 800 201 2 114 800 401 2 114 800 601 2 114 801 001 2 114 801 601 2 114 802 001 2 114 802 501 8 111 200 231 8 111 200 431 8 111 200 631 8 111 201 031 8 111 201 631 8 111 202 031 8 111 202 531 8 111 303 501 8 111 305 001 8 111 306 301 - - For more information visit our website at www.bussmann.com 18 D & D0 LOW VOLTAGE FUSE SYSTEM D&D0 CROSS REFERENCE TABLE Size Class D01 D02 DI / E16 Ultra Rapid DII / E27 DII / E33 DIV / R 1 1/4” DV / R 2” 19 Rating Bussmann 2 4 6 10 16 20 25 35 50 63 2 4 6 10 16 20 25 2 4 6 10 16 20 25 30 35 50 63 80 100 125 160 200 2NZ01R 4NZ01R 6NZ01R 10NZ01R 16NZ01R 20NZ02R 25NZ02R 35NZ02R 50NZ02R 63NZ02R 2D16R 4D16R 6D16R 10D16R 16D16R 20D16R 25D16R 2D27R 4D27R 6D27R 10D27R 16D27R 20D27R 25D27R 25D27R 35D33R 50D33R 63D33R 80D125R 100D125R 125D200R 160D200R 200D200R Ferraz Shawmut ETI M Schneider Siemens SIBA Weber Bals 1700.0026 1700.0046 1700.0066 1700.0106 1700.0166 1701.0206 1701.0256 1701.0356 1701.0506 1701.0636 597.0028 597.0048 597.0068 597.0108 597.0168 597.0208 597.0258 597.0308 598.0358 598.0508 598.0638 598.0808 598.1008 596.1258 596.1608 596.2008 4311001 4311002 4311003 4311004 4311005 4312001 4312002 4312003 4312004 4312005 4321001 4321002 4321003 4321004 4321005 4321006 4321007 4322001 4322002 4322003 4322004 4322005 4322006 4322007 4322008 4323001 4323002 4323003 4324001 4324002 4325001 4325002 4325002 011 002 011 004 011 006 011 010 011 016 012 020 012 025 012 035 012 050 012 063 013 002 013 004 013 006 013 010 013 016 013 020 013 025 014 002 014 004 014 006 014 010 014 016 014 020 014 025 015 035 015 050 015 063 016 080 016 100 017 125 017 160 017 200 5SD4 20 5SD4 30 5SD4 40 5SD4 80 5SD4 50 5SD4 60 5SD4 70 5SD5 10 5SD5 20 - 10 027 07 2A 10 027 07 4A 10 027 07 6A 10 027 07 10A 10 027 07 16A 10 028 07 20A 10 028 07 25A 10 028 07 35A 10 028 07 50A 10 028 07 63A 10 002 07 2A 10 002 07 4A 10 002 07 6A 10 002 07 10A 10 002 07 16A 10 002 07 20A 10 002 07 25A 10 005 07 2A 10 005 07 4A 10 005 07 6A 10 005 07 10A 10 005 07 16A 10 005 07 20A 10 005 07 25A 10 005 07 30A 10 007 07 35A 10 007 07 50A 10 007 07 63A 10 009 07 80A 10 009 07 100A 10 010 07 125A 10 010 07 160A 10 010 07 200A 2 175 200 201 2 175 200 401 2 175 200 601 2 175 201 001 2 175 201 601 2 175 202 001 2 175 202 501 2 175 203 501 2 175 205 001 2 175 206 301 - - For more information visit our website at www.bussmann.com