INSTALLATION INSTRUCTIONS &
USE & CARE GUIDE
Trade-Wind® Ventilators
MODEL: 810
80 CFM – 2.0 Sones
READ AND SAVE THESE INSTRUCTIONS
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and service
must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Installer:
Owner:
Please leave these installation instructions with the owner.
Please keep these installation instructions for local electrical inspector’s use and for future reference.
WARNINGS: Must be followed carefully to avoid personal injury.
TIPS: Contain helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel and lock service panel and lock the service
disconnection means to prevent power from being switch on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag to the service panel.
c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating equipment manufacturer's guidelines and safety standards such
as those published by the National Fire Protection Association (NFPA) and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f) Ducted fans must always be vented to the outdoors.
g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
h) Never place a switch where it can be reached from a tub or shower.
i) This unit must be grounded.
Item No. 0BV-00-011
Rev. 04/30/15
Copyright (C) 2003 Universal Metal Industries, Inc.
Page 1
CAUTION
- For general ventilating use only. Do not use to exhaust hazardous, explosive materials and/or vapors.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc.,
off power unit.
- Please read specification label on product for further information and requirements.
Recommendations:
1. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
2. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary, keep
turning radius as large and as smooth as possible.
3. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct joints
with high quality duct tape.
INSTALLATION INSTRUCTIONS
WARNING -- TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION –To reduce the risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air
into spaces with in walls or ceilings or into attics, crawl spaces, or garages.
PART 1
Installation
1. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and
a minimum number of elbows.
2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.
•
Additional positioning feature for 5/8", 1" & 1-1/4" thick ceiling material:
Holes in corners of housing are labeled with various ceiling material
thicknesses. Position housing so bottom edge of joist is visible through
a matched set of holes. The housing is now in the proper position for that
ceiling material thickness.
•
Additional positioning feature for 1/2" thick ceiling material:
Bend two tabs, on side of housing, 90 outward. Lift housing until tabs
contact underside of joist. Mark keyhole slot on both mounting brackets.
3. Set housing aside and drive nails partially
into joist at the top of both keyhole marks.
4. Hang housing from nails and pound nails tight. To ensure a noise-free mount,
pound another nail through the top hole of each mounting tab.
Item No. 0BV-00-011
Rev. 04/30/15
Copyright (C) 2003 Universal Metal Industries, Inc.
Page 2
5. Snap the damper/duct connector onto housing. Make sure that tabs on the
connector lock into slots in housing. Top of damper/duct connector should
be flush with top of housing.
6. Connect 4" round duct to damper/duct connector and extend duct to outside
through a roof or wall cap. Check damper to make sure that it opens freely.
Tape all duct connections to make them secure and air tight.
7. Wire unit following diagram. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top
of unit after installation is complete.
8. Squeeze grille springs together and insert springs
into slots in motor plate. Push grille up against ceiling.
PART 2
Use and Care
CLEANING & MAINTENANCE
- For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
- The motor is a ball bearing motor and never needs oiling. If the motor bearings are making excessive or unusual
noises, replace the blower assembly (includes motor and impeller).
CLEANING GRILLE:
CAUTION: Grille can be cleaned with mild, soapy water (use a mild detergent, such as dishwashing liquid) and dried with
a soft cloth. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS.
CLEANING FAN ASSEMBLY:
Unplug fan assembly. To remove motor plate: Find the single tab on the motor plate (located next to the receptacle).
Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in
housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND
ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
Item No. 0BV-00-011
Rev. 04/30/15
Copyright (C) 2003 Universal Metal Industries, Inc.
Page 3
WARRANTY
Trade-Wind® Series Kitchen Ventilation Products &
Trade-Wind® Ventilators
What is Covered
®
Universal Metal Industries, Inc., warrants its Trade-Wind Series Kitchen Ventilation products to the original user, to
be free of defects in materials and workmanship for three (3) years from the date of purchase Warranty on
®
Trade-Wind Ventilators applies as above, however, has a one (1) year parts replacement only, from the date of
purchase.
Universal Metal Industries, Inc., at its option, will repair or replace the complete unit or any defective component
without charge. This warranty may be voided if any unauthorized service, alterations or repairs are made to the
product.
What is Not Covered
•
•
•
•
•
Normal maintenance and service of any product that has been subject to misuse, negligence, accident or
installation inconsistent with the recommended installation instructions.
Product used other than for normal in-home use or products used outside of the United States.
Damage to the product caused by accident, fire, flood or other acts of God.
Service calls to educate the customer in the proper use and care of the product, change fuses or reset
breakers.
Service calls to correct faulty installation, such as, performance issues relating to improperly sized ducting or
restrictive roof caps.
Universal Metal Industries, Inc. disclaims and excludes any liability for implied warranties or for incidental or
consequential damages wherever permitted by law. There are no implied warranties of merchantability or fitness
for a particular use or purpose. This warranty gives you specific legal rights and you may also have other rights,
which vary from state to state.
For Service
If you need service, contact Customer Service at the address or phone number below. Provide the model number,
part identification and/or serial number and details of the problem. Proof of purchase must be provided.
Warranty Revised 08/01/14
For questions regarding this product, contact:
800 W. Grant St., Phoenix, Arizona 85007 (800) 875-3654
www.umiphx.com www.trade-windonline.com