468 KB - Sun Hydraulics

advertisement
Pilot Control Valves
Cartridge Type
Normally Open
Page
Normally Closed
2
2
2-position 2-way, Spool Directional
Valve - Pilot Capacity
122
Hydraulically Operated, 2-position
2-way, Spool Directional Valve - Pilot
Capacity
123
Air-operated, 2-position 2-way, Spool
Directional Valve - Pilot Capacity
124
Manually Operated, 2-position 2-way,
Spool Directional Valve - Pilot
Capacity
125
2-position 3-way, Spool Directional
Valve – Pilot Capacity
126
Hydraulically Operated, 2-position
3-way, Spool Directional Valve - Pilot
Capacity
127
Air-operated, 2-position 3-way, Spool
Directional Valve - Pilot Capacity
128
Manually Operated, 2-position 3-way,
Spool Directional Valve - Pilot
Capacity
129
Direct Acting, Adjustable Pilot Relief
130
Air-controlled, Directing Acting Pilot
Relief
131
Fully Adjustable Needle Valve - Pilot
Capacity
132
Electro-proportional Pilot Relief
133
1
1
Normally Closed
Normally Open
2
2
Ext.
Ext.
1
1
Normally Open
Normally Closed
2
2
Ext.
Ext.
1
1
Normally Open
Normally Closed
1
1
2
2
Normally Open 1-3
Normally Open 1-2
1
1
2 3
2 3
Normally Closed 1-3
Normally Open 1-2
1
1
Ext.
Ext.
3
2
3
2
Normally Open 1-2
Normally Closed 1-3
2 3
2 3
Ext.
Ext.
1
1
Normally Open
Normally Closed
1
1
2 3
2 3
1
2
Air Pilot
2
1
2
1
2
1
UK Shortcut Catalogue #999-901-244
121
Pilot Control Valves
Relief Valves
2-POSITION,
2-WAYBALANCED
SPOOL DIRECTIONAL
VALVE – PILOT CAPACITY
PILOT OPERATED,
PISTON
Normally
Closed
DAAA-MCN
2
Full Adjustment 5 Turns
+
-
2
1
2
1
c
b
Normally
Open
DAAA-MHN
c
Locating
Shoulder
1
Typical
Cartridge
Typical
Cartridge
Model Code
Capacity
Capacity
b
1 L/min.
Locating
a
Shoulder
2
Outlet
2
Inlet 1
Performance Curves
Model Code
DAAA – MCN
T - 8A
DAAA – MHN
T - 8A
DAAC – MCN
T - 8A
a
19,1
75
22,4
75
80
22,4
75
80
22,4
75
80
T - 162A
1.22
3/4”
25 GPM
T - 10A
1.56
7/8”
1 L/min.
RPEC – LAN
RPGC – LAN
T - 3A
100 GPM
1 L/min.
RPIC – LAN
200 GPM
RPKC – LAN
T - 8A
DAAC – MHNT - 16A
T - 18A
19,1
19,1
1.88
2.44
1 1/4”
3.13
1 5/8”
80
2.11
2.00
1 1/8”
19,1
L
22,4
RPCC – LAN
50 GPM
Port
Port 1
a
Cavity
12 GPM
1 L/min.
a
Cavity
Cartridge Dimensions
Cartridge Dimensions
c
b
c
M
C
b
2.12
2.44
2.81
Installation
Torque
Installation
Torque
(Nm)
K
(lb. ft.)
35/40
d
C
2.17
2.06
2.18
2.47
31
2.31
31
2.25
31
2.38
31
2.69
2.94
25/30
35/40
30/35
35/40
45/50
35/40
150/160
3.06
350/375
Performance Curves
RPCC
DAA*-M*N
RPGC
RPEC
RPIC
RPKC
5000
5000
25
4000
4000
4000
2000
1000
P = psi
3000
3000
2000
5
10
15
20
0
25
10
Flow = GPM
■
■
■
■
■
■
■
■
■
■
■
■
14
2000
7
1000
1000
0
20
3000
20
30
Flow = GPM
40
50
0
P = psi
35
5000
4000
P = psi
5000
4000
P = bar
5000
P = psi
P = psi
Pressure
vs. Flow
Typical
Pressure
Rise
3000
2000
1000
0 0.8 20 1.5 40 2.4 60 3.6 80 4 100
3000
2000
1000
0
40
= GPM
Q Flow
= L/min.
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating pressure = 5000 psi
Maximum
pressure
350
bar2.
Will acceptoperating
maximum
pressure= at
Port
Maximum leakage at 32 cSt = 10 drops/min. at 350 bar
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Switching frequency = 15000 cycles/hour
Factory pressure
settings established
GPM in some Sun pilot operated and ventable cartridges
Cartridge
can be installed
directly intoata4cavity
Typical
response
time operated
10 ms. pilot control functions.
to
provide
electrically
Maximum
leakage of
= RPCC,
in 3/min./1000
psi,
RPGC:
3 in
psi, RPIC:
Proper
installation
solenoidRPEC:
valves2requires
an extra
deep
socket
to3/min./1000
clear the solenoid
tube.4
3/min./1000 psi, RPKC: 5 in3/min./1000 psi.
in
Sockets are available from Snap On tools (P/N SIML280) or Sun Hydraulics (P/N 998-100-006).
RPCC
minimum setting for all
ranges is 75 psi
forspring
details.
See
www.sunhydraulics.com
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
D ARP
A A✱ –C M– ✱✱✱✱ –✱ ✱ ✱ ✱
A
Nominal
Nominal
Capacity
Capacity
C 12 GPM*
1 L/min.
Control**
$ 31.90
E
25 GPM
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
$ 97.30
K
200 GPM
$187.00
Control
Standard Screw +$ 0.00H
ML Manual
C Override
Tamper Resistant +$ 4.10
C
CK Concealed
Handknob
+$ 5.00
Override
Version
B 50 - 1500 psi
+$ 0.00
C 150 - 6000 psi
+$ 2.00
Normally Closed
N 60 - 800 psi
+$ 1.00
Seal
Q 60 - 400
psi
+$ 1.00
A Standard
N Buna-N
W 150 - 4500 psi
C Canadian
Standards
Association
Certified
240 bar max.
V Viton
** See page 162 for information
on Control Options
*
Adjustment Range
Spool Configuration
A 100 - 3000
Normally
Openpsi +$ 0.00
+$ 0.00
Seal
Coil Configuration*
N Buna-N ISO/DIN
+$ 0.00
V 206
Viton 6 VDC
+$ 2.00
212 12 VDC
224 24 VDC
211 115 VAC
223 230 VAC
SAE J858
506 6 VDC
512 12 VDC
524 24 VDC
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi. Twin Lead
N Option is standard set at 400 psi. 706 6 VDC
Q Option is standard set at 200 psi. 712 12 VDC
724 24 VDC
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Maximum Leakage (drops/min. at 350 bar
See page 167
for www.sunhydraulics.com
at 32 cSt for
/ 43°
C) = 10and complete technical information on our full line of products.
Visit
detailed
Solenoid Connector
Diameter Effective Orifice (mm) = 1,1
Power (Watts) = 12
6
US Shortcut Catalogue #999-901-243
Options
Operating Voltage Tolerance = ± 20%
Typical response Time (ms) = 30
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
122
UK Shortcut Catalogue #999-901-244
Pilot Control Valves
HYDRAULICALLY OPERATED, 2-POSITION 2-WAY, SPOOL DIRECTIONAL
VALVE - PILOT CAPACITY
Relief Valves
2
Normally
PILOT OPERATED, BALANCED
PISTON
Full Adjustment 5 Turns
+
-
Open
DAAH-*CN
Ext.
2
1
1
2 Normally
Closed
DAAH-*HN
cc
bb
Ext.
1
Locating
Cartridge Dimensions
Shoulder
Locating
Shoulder
Capacity
Capacity
a
OutletPort 1
Inlet 1
Performance Curves
a
T - 8A
19,1
22,4
Installation
Torque
Installation
(Nm)Torque
K
35/40(lb. ft.)
43
12 GPM
RPCC – LAN
T - 162A
1.22
3/4”
2.11
2.17
2.31
25 GPM
RPEC – LAN
T - 10A
1.56
7/8”
2.00
2.06
2.25
30/35
50 GPM
RPGC – LAN
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
25/30
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
T - 18A
3.13
1 5/8”
2.81
2.94
3.06
350/375
Performance Curves
RPCC
Cartridge Dimensions
a
b
cc
b
L
C
Cavity
1 L/min. Model Code
DAAH – BCN
a
2
Port
2
Typical
Typical Cartridge
Model CodeCavity
Cartridge
RPEC
RPGC
DAAH
RPIC
Pressure vs. Flow
RPKC
Typical Pressure Rise
2000
1000
3000
5000
4000
4000
143000
2000
5
10
20
15
0
25
10
Flow = GPM
■
■
■
■
■
■
■
■
■
■
■
■
■
20
30
Flow = GPM
40
0
50
3000
2000
1000
1000
1000
0
2000
7
P = psi
3000
5000
204000
P = psi
4000
P = bar
4000
255000
P = psi
5000
P = psi
P = psi
35
5000
0
0.8
1.5
20
2.4
40
60
3.6
Q =Flow
L/min.
= GPM
80
4
100
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating
operating pressure
pressure =
= 350
5000bar
psi
Maximum
Will accept maximum pressure at Port 2.
Maximum leakage at 32 cSt = 0,6 cc/min at 350 bar.
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Minimum pilot pressure to operate = 14 bar
Factory pressure settings established at 4 GPM
All ports will accept 350 bar including the pilot control port.
Typical response time 10 ms.
The preferred flow path through the valve
is port 2 to port 1.
Maximum leakage = RPCC, RPEC: 2 in 3/min./1000 psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
3
3
The
main
stage
valve
should
first
be
installed
in /min./1000 psi, RPKC: 5 in /min./1000 psi.to the correct torque value followed by the T-8A pilot
control
section into
the main
stage
valve
to itsisrequired
RPCC minimum
setting
for all
spring
ranges
75 psi torque value.
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP A
✱H
C –
– ✱
✱ ✱
✱✱
✱
DA
Nominal
Capacity
Nominal
C Capacity
12 GPM*
A
E
1 L/min.
25 GPM
$ 31.90
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
$ 97.30
K
200 GPM
$187.00
Control**
Adjustment Range
Pilot Port
Spool Configuration
L Standard Screw
A 1/8-27 NPTF
+$ 0.00
C Tamper Resistant +$ 4.10
K SAE-4
Handknob
B
+$ 5.00
D 1/8-28 BSPP
** See page 162 for information
on Control Options
Seal
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
B 50 - 1500 psi
+$ 0.00
V Viton
H Normally Open
150 - 6000Closed
psi
+$ 2.00
C Normally
N 60 - 800 psi
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
N Buna-N
+$ 2.00
V Viton
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
UK Shortcut Catalogue #999-901-244
123
Pilot Control Valves
AIR-OPERATED, 2-POSITION 2-WAY, SPOOL DIRECTIONAL
VALVE - PILOT CAPACITY
Normally
2
Relief Valves
Closed
DAAP-*CN
PILOT OPERATED, BALANCED
PISTON
Ext.
2
Full Adjustment 5 Turns
+
-
1
c
c
a
2
Port
Cartridge Dimensions
Locating
Shoulder
Locating
Shoulder
Typical
Cartridge
Model Code
Capacity
a
Performance Curves
Inlet 1
3/4”
2.11
2.17
2.31
RPEC – LAN
T - 10A
1.56
7/8”
2.00
2.06
2.25
30/35
50 GPM
RPGC – LAN
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
T - 18A
DAAP
3.13
1 5/8”
2.81
2.94
3.06
350/375
3000
2000
1000
K
20
3000
2000
■
10
20
30
40
RPKC
145000
5000
5000
74000
4000
4000
3000
0
0.8
2000
1.5
2.4
Q = L/min.
3.6
4
0
50
3000
2000
1000
1000
0
25
RPIC
Typical Pressure Rise
20
1000
Flow = GPM
19,1
25
P = bar
4000
RPGC
35
P = psi
5000
4000
P = psi
P = psi
5000
15
Cartridge Dimensions
22,2
c 42,2
b
L
C
12 GPM
RPEC
10
Installation
Torque
(Nm)
35/40
Installation
c
Pressure vs. Flow
RPCC
5
b
25 GPM
Performance Curves
0
a
Torque
(lb. ft.)
25/30
Capacity
2
Outlet
Cavity
T - 8A
DAAP – FCN
Typical
Cartridge
Cavity
a
Model Code
T - 162A
1.22
RPCC – LAN
1 L/min.
1 Port
1
P = psi
b
1
P = psi
b
Ext.
Normally
Open
2
DAAP-*HN
20
40
60
80
100
3000
2000
1000
0
40
80
120
160 200
0
80
160
240
320 400
MaximumFlow
operating
bar = GPM
Flow = GPM
Flow = GPM
= GPM pressure = 350 Flow
Maximum operating
leakage atpressure
32 cSt ==0,6
cc/min.
Maximum
5000
psi at 350 bar
Maximum
pressure
= 5 barat Port 2.
Will
acceptpilot
maximum
pressure
Minimum
piloton
pressure
operate
1,5
+ portadditive
1 pressure/7
bar
Back
pressure
the tanktoport
(port=2)
is bar
directly
at a 1:1
ratio to the valve setting.
All
ports
will
accept
350
bar
with
the
exception
of
the
pilot
port
which
accepts 35 bar maximum.
Factory pressure settings established at 4 GPM
Typical
response
time
10through
ms.
The preferred
flow
path
the valve is port 2 to port 1.
3/min./1000 psi, RPIC: 4
Maximum
leakage
= RPCC,
in 3/min./1000
psi, RPGC:
3 in
The main stage
valve
should RPEC:
first be 2installed
to the correct
torque
value
followed by the T-8A pilot
3/min./1000 psi, RPKC: 5 in3/min./1000 psi.
in
control
section into the main stage valve to its required torque value.
■
■
■
■
■
■
■
■
■
■
RPCC minimum setting for all spring ranges is 75 psi
■
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP ✱
DA
AC
P –
– ✱
✱ ✱
✱✱
✱
Nominal
Nominal
Capacity
C
Control**
Pilot Port
Capacity
12 GPM*
$ 31.90
L Standard Screw
E
25 GPM
$ 36.20
G
50 GPM
I
K
A
Adjustment Range
Seal
Spool Configuration
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
C Tamper Resistant +$ 4.10
B 50 - 1500 psi
+$ 0.00
V Viton
$ 51.80
F Handknob
1/8-27 NPTF
K
C 150
Normally
C
- 6000Closed
psi
+$ 2.00
V Viton
100 GPM
$ 97.30
P 1/8-28 BSPP
200 GPM
$187.00
1 L/min.
E SAE-4
+$ 0.00
+$ 5.00
** See page 162 for information
on Control Options
H Normally Open
N 60 - 800 psi
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
N Buna-N
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 2.00
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
124
UK Shortcut Catalogue #999-901-244
6
US Shortcut Catalogue #999-901-243
Pilot Control Valves
MANUALLY OPERATED, 2-POSITION 2-WAY, SPOOL DIRECTIONAL
Relief
Valves
VALVE
- PILOT CAPACITY
PILOT OPERATED, BALANCED PISTON
1
1
2
2
2
1
1
1
1
H Spool:
Normally
2 Open
1
c
b
c
a
2
Outlet
2
Port
Inlet1 1Port
= Twist (Momentary)
= Lock (Detent)
C Spool:
Normally
Closed
Locating
Shoulder
b
T Control
L Control
D Control
d 5 Turns
Full Adjustment
+
-
a
Capacity
Typical
2 Cartridge
Model Code
12 GPM
RPCC – LAN
25 GPM
RPEC – LANTypicalT - 10A
Cavity
2
T - 162A
Model Code
100 GPM
RPIC – LAN
T - 16A
200 GPM
RPKC – LAN
T - 18A
1 L/min.
Locating
Shoulder
a
2
Capacity RPGC – LAN
Cartridge
50 GPM
T - 3A
DAAM - TCN
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
25/30
K
1.22
3/4”
2.11
2.17
2.31
1.56
7/8”
2.00
2.06
2.25
30/35
Installation
Cavity
1.88
a
1 1/8”
b2.12
c 2.18 d
2.38 Torque 45/50
2.44
1 1/4”
3.13
1 5/8”
T-8A
Cartridge Dimensions
2.44
19,1
28,6
61
2.81
2.47
35,6
2.94
2.69
(Nm)
150/160
35/40
3.06
350/375
Performance Curves
Performance Curves
RPCC
RPEC
RPGC
RPIC
RPKC
5000
5000
5000
5000
4000
4000
4000
4000
4000
1000
2000
1000
0
5
10
20
15
0
25
10
Flow = GPM
■
■
■
■
■
■
■
■
■
■
■
20
30
Flow = GPM
40
50
P = psi
2000
3000
P = barP = psi
3000
Pressure vs. Flow
35
3000
2000
25
3000
2000
1000
1000
20
14 0
P = psi
5000
P = psi
P = psi
Typical DAAM
Pressure Rise
20
7
40
60
Flow = GPM
80
100
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
4
3.6
2.4
1.5
0.8 psi
Maximum operating pressure =0 5000
Q = L/min.
Will accept maximum pressure at Port 2.
Back
pressure
on the pressure
tank port=(port
Maximum
operating
350 2)
baris directly additive at a 1:1 ratio to the valve setting.
Factory
pressure
settings
established
at 4 GPM
Maximum
leakage
at 32 cSt
= 0,6 cc/min.
at 350 bar
Typical
response
time
10
ms.
The preferred flow path through the valve is port 2 to port 1.
3/min./1000 psi, RPIC: 4
Maximum
leakage
= RPCC,
in 3/min./1000
psi, RPGC:
3 in
The main stage
valve
should RPEC:
first be 2installed
to the correct
torque
value
followed by the T-8A pilot
in3/min./1000 psi, RPKC: 5 in3/min./1000 psi.
control section into the main stage valve to its required torque value.
RPCC minimum setting for all spring ranges is 75 psi
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
DA ✱
AC
M – ✱ ✱✱
Nominal
Nominal
Capacity
C
Capacity
Control**
Adjustment Range
Pilot Port
$ 31.90
L Standard Screw
E
25 GPM
$ 36.20
C Tamper
Resistant +$ 4.10
(Twist/Lock)
G
50 GPM
$ 51.80
K Handknob
I
100 GPM
$ 97.30
A
K
1 L/min.
200 GPM
$187.00
D Dual
L Lock (Detent)
Seal
Spool Configuration
12 GPM*
+$ 0.00
+$ 5.00
T Twist
(Momentary)
NOTE: Designed for 10,000
cycles of operation maximum
under normal conditions.
** See page 162 for information
on Control Options
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
B 50 - 1500 psi
+$ 0.00
V Viton
H 150
Normally
C
- 6000 Open
psi
+$ 2.00
V Viton
C Normally Closed
N 60 - 800 psi
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
N Buna-N
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 2.00
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
Visit www.sunhydraulics.com for detailed and complete technical
6 information on our full line of products.
US Shortcut Catalogue #999-901-243
UK Shortcut Catalogue #999-901-244
125
Relief Valves
Pilot Control Valves
PILOT OPERATED, BALANCED PISTON
2-POSITION,
3-WAY SPOOL DIRECTIONAL VALVE – PILOT CAPACITY
Full Adjustment 5 Turns
+
-
Normally
Open 1-2
DBAA-MHN
1
1
d
2
1
c
b
2 3
Normally
Open 1-3
DBAA-MCN
Locating
Shoulder
c
Capacity
Capacity
a
b 2
12 GPM
Locating
Shoulder
Outlet
3
Port
a
Cavity
Cartridge
Cartridge Dimensions c
b
L c
C
b
3/4”
M2.11
C 2.17
a
Cavity
a
RPCC Model
– LANCode T - 162A
1.22
Installation
Torque
K Installation
(lb. ft.)
Torque
2.31
25/30
(Nm)
d
25 1GPM
L/min.
RPECDBAA
– LAN
T - 9A
– MCNT - 10A
1.56
27,7
7/8”
22,4
752.00
80 2.06 30,2 2.25
30/35
35/40
50 1GPM
L/min.
RPGC
– LAN
T - 9A
DBAA
– MHNT - 3A
RPICDBAC
– LAN
T - 9A
– MCNT - 16A
T - 18A
RPKC – LAN
1.88
27,7
1 22,4
1/8”
752.12
45/50
35/40
2.44
27,7
1 22,4
1/4”
752.44
80 2.18 30,2 2.38
80 2.47 30,2 2.69
3.13
1 5/8”
2.81
1001GPM
L/min.
2 Inlet 1
Port
Port 1
Cartridge Dimensions
2 3
Typical
Cartridge
Typical
Model Code
200 GPM
1 L/min.
DBAC – MHN
T - 9A
27,7
22,4
75
80
2.94
30,2
3.06
150/160
35/40
350/375
35/40
Performance Curves
RPCC
Performance
Curves
RPEC
RPGC
RPIC
RPKC
Typical Pressure Rise
5000
5000
4000
4000
4000
4000
4000
1000
2000
1000
0
5
10
15
20
0
25
10
Flow = GPM
■
■
■
■
■
■
■
■
■
20
30
Flow = GPM
40
50
P = psi
2000
3000
P = bar
3000
Pressure vs. Flow
3000
35
2000
25
1000
20
14
P = psi
5000
P = psi
5000
P = psi
P = psi
DBA*-M*N
5000
3000
2000
1000
0
20
7
40
60
Flow = GPM
80
2000
1000
0
100
3000
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
0.8
1.5psi2.4
3.6
4
Maximum operating pressure0= 5000
Q = L/min.
Will accept maximum pressure at Port 2.
Back pressure
on the pressure
tank port=(port
2) is directly additive at a 1:1 ratio to the valve setting.
Maximum
operating
350 bar
Factory
pressure
settings
established
at 4 GPM
Maximum leakage at 32 cSt = 0,6 cc/min.
at 350 bar
Typical response
time=10
ms. cycles/hour
Switching
frequency
15000
Proper
installation
solenoidRPEC:
valves2requires
an extra
deep
socket
to3/min./1000
clear the solenoid
tube.4
Maximum
leakage of
= RPCC,
in 3/min./1000
psi,
RPGC:
3 in
psi, RPIC:
3
3
in /min./1000
psi, RPKC:
in /min./1000
psi. SIML280) or Sun Hydraulics (P/N 998-100-006).
Sockets
are available
from5Snap
On tools (P/N
forspring
details.
See
www.sunhydraulics.com
RPCC
minimum setting for all
ranges is 75 psi
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
D BRP
A A✱ –C M– ✱✱✱✱ –✱ ✱ ✱ ✱
A
Nominal
Nominal
Capacity
Capacity
C 12 GPM*
1 L/min
E
25 GPM
Control**
$ 31.90
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
$ 97.30
K
200 GPM
$187.00
Adjustment Range
Control
Standard Screw
ML Manual
Override
Spool Configuration
+$ 0.00H Normally
A 100 - 3000
Openpsi +$ 0.00
Ports 1 to 2
CK Concealed
Handknob
Override
Openpsi
+$ 5.00C Normally
C 150 - 6000
Ports 1 to 3
C Tamper Resistant +$ 4.10
Version
B 50 - 1500 psi
N 60 - 800 psi
Seal
Q 60 - 400 psi
A
Standard
N Buna-N
C
Canadian
Standards
Association
Certified
240 bar max.
V Viton
** See page 162 for information
on Control Options
W 150 - 4500 psi
+$ 0.00
+$ 2.00
+$ 1.00
+$ 1.00
+$ 0.00
Seal
Coil Configuration*
N Buna-N ISO/DIN
+$ 0.00
206 6 VDC
V 212
Viton 12 VDC
+$ 2.00
224 24 VDC
211 115 VAC
223 230 VAC
SAE J858
506 6 VDC
512 12 VDC
524 24 VDC
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi. Twin Lead
706 6 VDC
N Option is standard set at 400 psi.
712 12 VDC
Q Option is standard set at 200 psi. 724 24 VDC
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
US Shortcut Catalogue #999-901-243
Maximum Leakage (drops/min. at 350 bar 6
*
See page 167 for
Solenoid Connector
Options
at 32 cSt / 43° C) = 10
Diameter Effective Orifice (mm) = 1,1
Operating Voltage Tolerance = ± 10%
Power (Watts) = 12
Typical response Time (ms) = 30
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
126
UK Shortcut Catalogue #999-901-244
Pilot Control Valves
Relief
Valves
HYDRAULICALLY
OPERATED, 2-POSITION 3-WAY, SPOOL DIRECTIONAL
PILOT
BALANCED PISTON
VALVEOPERATED,
- PILOT CAPACITY
Full Adjustment 5 Turns
+
-
1
Normally
Open 1-3
DBAH-*CN
1
Ext.
2
1
c
3
2
b
c
Normally
Open 1-2
DBAH-*HN
Locating
Shoulder
b
a
32
Outlet
Port
2 3
Typical
Cartridge
Model Code
1.22
3/4”
2.11
2.17
Capacity RPEC – LAN
Cartridge
25 GPM
T - 10A
Cavity
1.56
a
7/8”
b
2.00
2.06c
2.25
50 GPM
T - 3A
LAN – BCN
1 L/min. RPGC – DBAH
T - 16A
RPIC – LAN
1.88
T - 9A
127,7
1/8”
2.12
22,2
2.18
43
2.38
2.44
1 1/4”
2.44
2.47
2.69
150/160
3.13
1 5/8”
2.81
2.94
3.06
350/375
Cavity
a
Model Code
100 GPM
2
Inlet 1
Port
RPKC – LAN
200 GPM
K
Cartridge Dimensions
RPCC – LAN
TypicalT - 162A
12 GPM
a
Cartridge Dimensions
c
b
L
C
Installation
Torque
(lb. ft.)
2.31 Installation
25/30
Capacity
Locating
Shoulder
Ext.
T - 18A
Torque
30/35
(Nm)
45/50
35/40
Port 1 Curves
Performance
RPCC
RPEC
RPGC
4000
3000
2000
1000
3000
2000
15
20
0
25
10
Flow = GPM
■
■
■
■
■
■
■
■
■
■
■
Pressure vs. Flow
3000
2000
20
30
Flow = GPM
40
50
5000
5000
4000
4000
3000
2000
1000
1000
P = bar
10
DBAH
35
1000
5
RPKC
P = psi
4000
P = psi
5000
4000
P = psi
5000
0
RPIC
Typical Pressure Rise
5000
P = psi
P = psi
Performance Curves
3000
2000
1000
25
0
20
20
14
40
60
Flow = GPM
80
100
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating pressure7 = 5000 psi
3.6
0
1.5 2.2.4
4
Will accept maximum pressure
at0.8Port
Q = L/min.
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Factory
pressure
settings
established
at 4 GPM
Maximum
operating
pressure
= 350 bar
Typical
response
time
10
ms.
Maximum leakage at 32 cSt = 0,6 cc/min. at 350 bar
Maximum leakage = RPCC, RPEC: 2 in 3/min./1000 psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
Minimum
pilotpsi,
pressure
= 14 bar
3/min./1000
in
RPKC:to5operate
in3/min./1000
psi.
All ports
will accept
350for
barall
including
the pilot
control
RPCC
minimum
setting
spring ranges
is 75
psi port.
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
DB ✱
AC
H –
– ✱
✱ ✱
✱✱
✱
Nominal
Capacity
Nominal
Control**
Adjustment Range
Pilot Port
Spool Configuration
C Capacity
12 GPM*
$ 31.90
L Standard Screw
E
$ 36.20
C Tamper Resistant +$ 4.10
A
25 GPM
G
50 GPM
$ 51.80
K Handknob
I
100 GPM
$ 97.30
B SAE-4
K
200 GPM
$187.00
D 1/8-28 BSPP
1 L/min.
A 1/8-27 NPTF
+$ 0.00
+$ 5.00
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
B 50 - 1500 psi
+$ 0.00
V Viton
N 60 - 800 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
H Normally Open
C 150
Ports- 6000
1 to 2psi +$ 2.00
C Normally Open
Q 60
- 400
+$ 1.00
Ports
1 topsi
3
** See page 162 for information
on Control Options
Seal
+$ 2.00
N Buna-N
V Viton
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
UK Shortcut Catalogue #999-901-244
127
Pilot
ReliefControl
Valves Valves
AIR-OPERATED,
2-POSITION
3-WAY,
SPOOL DIRECTIONAL
PILOT OPERATED,
BALANCED
PISTON
VALVE
- PILOT CAPACITY
Full Adjustment 5 Turns
+
-
2 3
2
Ext.
c
b
2 3
1
c
b
Locating
Shoulder
Normally
Open 1-3
DBAP-*CN
Capacity
Locating
Shoulder
a
2
3
Outlet
Port
2
Port
Normally
Open 1-2
DBAP-*HN
1
Typical
1
Cartridge
Model Code
RPCC – LAN
Typical
12 GPM
Capacity
25 GPM
a
Ext.
Cavity
a
T - 162A
1.22
Cartridge
Cavity
RPEC –Model
LANCode T - 10A
1.56
Cartridge Dimensions
c
b
L
C
Cartridge Dimensions
3/4”
a
50 GPM
– LAN– FCNT - 3AT - 9A 1.8827,7
1 L/min. RPGCDBAP
100 GPM
T - 16A
2.44
RPIC – LAN
Inlet 1
RPKC – LAN
200 GPM
1 Port
T - 18A
3.13
2.11
45/50
1 1/8”
22,2
2.1242,2
1 1/4”
2.44
2.47
2.69
150/160
1 5/8”
2.81
2.94
3.06
350/375
2.00
c
2.17Installation
2.31
Torque
(Nm)2.25
2.18 35/402.38
7/8”
b
Installation
Torque
(lb. ft.)
25/30
K
2.06
30/35
Performance Curves
RPCC
RPEC
RPGC
4000
3000
2000
1000
3000
20
15
0
25
Pressure vs. Flow
3000
10
Flow = GPM
20
30
Flow = GPM
40
50
25
0
20
5000
5000
4000
4000
3000
2000
1000
1000
P = bar
10
DBAP
2000
35
2000
1000
5
RPKC
P = psi
4000
P = psi
5000
4000
P = psi
5000
0
RPIC
Typical Pressure Rise
5000
P = psi
P = psi
Performance Curves
20
14
40
60
Flow = GPM
80
100
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
7
Maximum operating pressure
= 5000 psi
3.6
0
1.5 2.2.4
4
Will accept maximum pressure
at0.8Port
Q = L/min.
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Maximum
operating
pressure
= 350 bar
Factory pressure
settings
established
at 4 GPM
Maximum
leakagetime
at 32
Typical response
10cSt
ms.= 0,6 cc/min. at 350 bar
Maximum
pressure
= 5 bar
Maximum pilot
leakage
= RPCC,
RPEC: 2 in 3/min./1000 psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
Minimum
pilotpsi,
pressure
= 1,5 bar
+ port 1 pressure/7 bar
in3/min./1000
RPKC:to5operate
in3/min./1000
psi.
All
ports
will
accept
350
bar
with
the
exception
of psi
the pilot port which accepts 35 bar maximum.
RPCC minimum setting for all spring ranges is 75
■
■
■
■
■
■
■
■
■
■
■
■
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
✱A
C P
– ✱
✱ ✱
D B
– ✱✱✱
Nominal
C
A
E
Control**
Nominal
Capacity
Capacity
Adjustment Range
Pilot Port
12 GPM*
$ 31.90
25 GPM
$ 36.20
1 L/min.
L Standard Screw
E SAE-4
+$ 0.00
C Tamper Resistant +$ 4.10
G
50 GPM
$ 51.80
F
NPTF
K 1/8-27
Handknob
I
100 GPM
$ 97.30
P 1/8-28 BSPP
K
200 GPM
$187.00
+$ 5.00
** See page 162 for information
on Control Options
Seal
Spool Configuration
A 100 - 3000 psi
+$ 0.00
H Normally Open
B Ports
50 - 1500
+$ 0.00
1 to 2psi
C 150 - 6000 psi
+$ 2.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
C Normally Open
N Ports
60 - 800
+$ 1.00
1 topsi
3
Seal
N Buna-N +$ 0.00
N Buna-N
V Viton
+$ 2.00
V Viton
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
128
UK Shortcut Catalogue #999-901-244
Relief Valves
Pilot Control Valves
PILOT OPERATED, BALANCED PISTON
MANUALLY OPERATED, 2-POSITION 3-WAY, SPOOL DIRECTIONAL
Full Adjustment 5 Turns
VALVE
- PILOT
CAPACITY
+
D Control
2
d
L Control
T Control
1
1
2 3
2 3
2 3
1
1
1
1
c
H Spool:
Normally
Open
b
Locating
Shoulder
Capacity
C Spool:
Normally
12 GPM
Closed
25 GPM
a
c
b
Port
2000
2.11
2.17
2.31
7/8”
2.00
2.06
2.25
30/35
1.88
1 1/8”
2.12
2.18
2.38
45/50
2.69
1000
5
10
20
15
RPIC – LAN
T - 16A
2.44
1 Cartridge
1/4”
2.44
2.47
Dimensions
T - 18A
3.13
1 5/8”
Cartridge
Model Code
DBAM – TCN
1 L/min.
■
■
■
■
■
■
■
■
T - 9A
RPGC
a
27,7
RPIC
b
28,6
2.94
c
61
150/160
3.06 Installation
350/375
d
Torque
(Nm)
35/40
35,6
RPKC
5000
5000
5000
4000
4000
4000
4000
3000
2000
DBAM
3000
2000
Pressure vs. Flow
10
20
30
40
Flow = GPM
0
50
20
35
40
60
Flow = GPM
80
3000
2000
1000
1000
Flow = GPM
100
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
25
Maximum operating pressure
= 5000 psi
20
Will accept maximum pressure
at Port 2.
14
7
Back pressure on the tank port
(port 2) is directly additive at a 1:1 ratio to the valve setting.
3.6
0
4
1.5
0.8
Factory pressure settings established
at 42.4GPM
Q = L/min.
Typical response time 10 ms.
Maximum leakage
operating
= 350 2bar
Maximum
= pressure
RPCC, RPEC:
in 3/min./1000 psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
3/min./1000
Maximum
leakage
at 32 cSt
=30,6
cc/min. psi.
at 350 bar
in
psi, RPKC:
5 in
/min./1000
All ports
will accept
350for
bar.all spring ranges is 75 psi
RPCC
minimum
setting
P = bar
■
Cavity
2.81
5000
0
25
■
2 3
T - 3A
Typical
RPKC – LAN
1000
0
2 3
P = psi
3000
3/4”
1.56
Typical Pressure Rise
P = psi
P = psi
5000
Performance
Curves
4000
1.22
T - 10A
K
100 GPM
RPEC
Locating
Shoulder
T - 162A
RPEC – LAN
P = psi
1 Port
RPCC – LAN
RPGC – LAN
Capacity
Installation
Torque
(lb. ft.)
25/30
a
200 GPM
3
a
Performance
2
Port Curves
RPCC
= Twist
(Momentary)
Cartridge
Dimensions
c
= Lock (Detent)
b
L
C
Cavity
2 3
50 GPM
Inlet 1
Typical
Cartridge
Model Code
P = psi
2
Outlet
1
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
✱
D ✱
BC
A –
M✱
– ✱
✱✱✱
Nominal
Nominal
Capacity
C
Capacity
Control**
12 GPM*
$ 31.90
L Standard Screw
E
25 GPM
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
$ 97.30
K
200 GPM
$187.00
A
1 L/min.
Adjustment Range
Pilot Port
Seal
Spool Configuration
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
C Tamper
Resistant +$ 4.10
(Twist/Lock)
B 50
- 1500
Open
1-3 psi
+$ 0.00
V Viton
K Handknob
C 150 - 6000 psi
+$ 2.00
V Viton
D Dual
L Lock (Detent)
+$ 0.00
+$ 5.00
T Twist
(Momentary)
NOTE: Designed for 10,000
cycles of operation maximum
under normal conditions.
** See page 162 for information
on Control Options
C Normally
H Normally
N 60
- 800
Open
1-2psi
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
N Buna-N
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 2.00
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
UK Shortcut Catalogue #999-901-244
129
Relief Valves
PILOT
OPERATED,
BALANCED PISTON
Pilot
Control
Valves
Full AdjustmentACTING,
5 Turns
DIRECT
ADJUSTABLE PILOT RELIEF
+
-
Full Adjustment 5 Turns
+
-
c
2
1
2
1
b
Locating
Shoulder
Cartridge Dimensions
Cartridge Dimensionsc
b
cC
L
c
Capacity
Capacity
a
b
2
Outlet
12 GPM
Cavity
Cartridge
a
Cavity
a
RPCC Model
– LANCode T - 162A
2510
GPM
L/min. RPECRBAE
T - 8A
– LAN
– LANT - 10A
Locating
Shoulder
a
2Inlet 1
Port
Port 1
Performance
Curves
RPCC
Performance
Curves
Typical
Cartridge
Typical
Model Code
Installation
K
1.22
3/4”
b
L
2.11
C
2.17
K
2.31
1.56
19,1
7/8”
22,2
2.00
61
2.06
63
2.25
68
Torque
Installation
(lb. ft.)
Torque
25/30
(Nm)
30/35
35/40
50 GPM
RPGC – LAN
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
T - 18A
3.13
1 5/8”
2.81
2.94
3.06
350/375
RPEC
RPGC
RPIC
RPKC
5000
5000
4000
4000
4000
4000
2000
1000
3000
350
3000
2000
250
2000
1000
0
5
10
20
15
10
Flow = GPM
20
30
Flow = GPM
40
50
140
3000
2000
1000
1000
200
0
25
P = psi
3000
Pressure vs. Flow
P = psi
5000
4000
P = bar
P = psi
5000
P = psi
P = psi
Typical Pressure
RBAE Rise
5000
0
20
70
40
60
Flow = GPM
80
100
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating pressure0= 5000
4 psi 8
12
Q = L/min.
Will accept maximum pressure at Port
2.
Back
pressure
on the pressure
tank port=(port
2) is directly additive at a 1:1 ratio to the valve setting.
Maximum
operating
350 bar
Factory
pressure
settings
established
at 4 GPM
Maximum
leakage
= 0,3 cc/min.
at reseat
(reseat = 85% of cracking pressure).
Ports 1 and
2 maytime
be pressured
Typical
response
10 ms. to 350 bar.
Back pressure
at port
2 (outlet)
is directly
additive topsi,
the RPGC:
pressure3setting
at port 1psi,
(inlet).
Maximum
leakage
= RPCC,
RPEC:
2 in 3/min./1000
in3/min./1000
RPIC: 4
3/min./1000
3/min./1000
The
main stagepsi,
valve
should
be installed
in
RPKC:
5 infirst
psi.to the correct torque value followed by the T-8A pilot
controlminimum
section into
the main
stage
valve
to itsisrequired
RPCC
setting
for all
spring
ranges
75 psi torque value.
■
■
■
■
■
■
■
■
■
■
■
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
✱
R ✱
BC
A –
E ✱
– ✱
✱✱✱
Nominal
Nominal
Capacity
C
A
E
Control**
Capacity
12 GPM*
10 L/min.
25 GPM
Control**
$ 31.90
L Standard Screw
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
$ 97.30
K
200 GPM
$187.00
Adjustment Range
Seal
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
C Tamper Resistant +$ 4.10
B 50 - 1500 psi
+$ 0.00
V Viton
C Handknob
Concealed
K
B 150
2 - 105
bar psi
C
- 6000
+$ 2.00
V Viton
N 60 - 800 psi
C 2 - 420 bar
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
L Standard Screw
+$ 0.00
Adjustment Range
+$ 5.00
K Handknob
A 2 - 210 bar
D 2 - 55 bar
N Buna-N
+$ 2.00
E 2 - 25 bar
** See page 162 for information
on Control Options
Adjustment Range Options:
W B,
2 C,
- 315
A,
andbar
W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
Adjustment Range Options:
6
US Shortcut Catalogue #999-901-243
** See page 162 for information
on Control Options
A, B, C, and W are standard set at 70 bar.
D Option is standard set at 25 bar.
E Option is standard set at 14 bar.
Customer may specify pressure setting.
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
130
UK Shortcut Catalogue #999-901-244
Relief Valves
Pilot Control Valves
PILOT OPERATED, BALANCED PISTON
AIR-CONTROLLED, DIRECTING ACTING PILOT RELIEF
Full Adjustment 5 Turns
+
Air Pilot
1
2
c
b
2
1
c
Locating
Shoulder
b
Locating
aShoulder
2
Outlet
2
Port
Cartridge Dimensions
Dimensions
Cartridge
c
ab
b
c
L
C
Typical Typical
Capacity
Capacity CartridgeCartridge Cavity Cavity a
Model Code
Model Code
12 GPM
T - 162A T - 8A
1.22
LAN – AWN
10 L/min.RPCC – RBAR
25 GPM
T - 10A T - 8A
1.56
LAN – AYN
10 L/min.RPEC – RBAR
50 GPM
T - 3A
1.88
RPGC – LAN
a
Inlet 1
Port 1
3/4”
19,1
2.11
22,2
2.1741
Installation
Installation
Torque
Torque
(lb. ft.)
(Nm)
2.31
25/30
35/40
7/8”
19,1
2.00
28,6
2.0641
2.25
1 1/8”
2.12
2.18
2.38
45/50
K
30/35
35/40
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
T - 18A
3.13
1 5/8”
2.81
2.94
3.06
350/375
Performance Curves
Performance Curves
RPCC
RPEC
RPGC
RPIC
RBAR
RPKC
Typical Pressure Rise
1000
2000
1000
0
5
10
20
15
10
Flow = GPM
20
2000
1000
70
0
25
140
3000
30
1,4
Flow =0 GPM
40
3
50
4
■
■
■
■
■
■
■
■
■
■
■
■
140
70
0
5,5
20
7
Air Pressure - bar
■
380
210
40
60
0
Flow = GPM
80
100
5000
5 bar Air
5000
4000
4 bar Air
4000
3000
3 bar Air
2000
2 bar Air
1000
1,4 bar Air
4
0
40
Flow = L/min.
80
8
Flow
120
= GPM
P = psi
2000
3000
420
350
P = psi
3000
380
210
4000
P = bar
4000
Pressure vs. Flow
5000
420
350
P = psi
4000
Hydraulic
Pressure
5000
P = psi
P = psi
Air to Oil at 0,4 L/min.
5000
3000
2000
1000
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating pressure = 5000 psi
Will
acceptoperating
maximumpressure
pressure=at350
Port
Maximum
bar2.
Back
pressure
on the
port (port
2) isbar
directly additive at a 1:1 ratio to the valve setting.
Maximum
leakage
= tank
0,3 cc/min.
at 350
Maximum
pilot pressure
= 10,5 bar at 4 GPM
Factory
pressure
settings established
Ports 1 and
2 maytime
be pressured
Typical
response
10 ms. to 350 bar.
Back pressure
at port
2 has no
effect2on
valve setting.
Maximum
leakage
= RPCC,
RPEC:
in 3the
/min./1000
psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
3/min./1000
3/min./1000
The
main stagepsi,
valve
should
be installed
in
RPKC:
5 infirst
psi.to the correct torque value followed by the T-8A
pilot control
section
intofor
theall
main
stage
valveisto75itspsi
required torque value.
RPCC
minimum
setting
spring
ranges
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
✱
R ✱
BC
A –R ✱
– ✱
✱✱✱
Nominal
Nominal
Capacity
C
Capacity
Control**
Adjustment Range
Port
12 GPM*
$ 31.90
L Standard Screw
E
25 GPM
$ 36.20
C Tamper
Resistant +$ 4.10
Pilot Port
G
50 GPM
$ 51.80
K Handknob
I
100 GPM
$ 97.30
K
200 GPM
$187.00
A
10 L/min.
A 1/8-27 NPTF
B SAE-4 Pilot Port
Seal
Air Pilot Ratio
+$ 0.00
+$ 5.00
D 1/8-28 BSPP Port
** See page 162 for information
on Control Options
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
B 50 - 1500 psi
+$ 0.00
V Viton
Y 150
75:1- 6000 psi
C
+$ 2.00
V Viton
W 50:1
N 60 - 800 psi
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
N Buna-N
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 2.00
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
UK Shortcut Catalogue #999-901-244
131
Relief Valves
PILOT OPERATED, BALANCED PISTON
Full Adjustment 5 Turns
+
-
1
2
c
b Control Valves
Pilot
Locating
Shoulder
FULLY ADJUSTABLE
NEEDLE VALVE - PILOT CAPACITY
Cartridge Dimensions
a
2
Outlet
c
RPCC – LAN
T - 162A
1.22
3/4”
2.11
2.17
2.31
RPEC – LAN
T - 10A
1.56
7/8”
2.00
2.06
2.25
30/35
50 GPM
RPGC – LAN
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
1
RPKC – LAN
T - 18A
3.13
1 5/8”
2.81
2.94
3.06
350/375
Cartridge Dimensions
P = psi
Typical
RPGC
Cartridge
Model Code
Cavity
NFAB – KXN
T - 8A
5
10
20
15
4000
3000
2000
5000
4000
4000
3000
2000
10
Flow = GPM
20
30
Flow = GPM
40
22,2
27,9
5000
3000
2000
1000
0
50
20
40
60
Flow = GPM
80
100
Installation
Torque
(Nm)
35/40
RPKC
c
b
19,1
5000
1000
0
25
RPICa
Typical Pressure Rise
1000
0
Installation
Torque
(lb. ft.)
25/30
K
12 GPM
0,9 mm
1000
C
25 GPM
5000
Port 1
c
L
P = psi
a
P = psi
b
RPEC Maximum
Orifice
2
5000
Port
4000
2000
a
Locating
Shoulder
RPCC
3000
Cavity
P = psi
b
Performance Curves
Typical
Cartridge
Model Code
P = psi
Inlet 1
Capacity
2
4000
3000
2000
1000
0
40
80
120
Flow = GPM
160 200
0
80
160
240
Flow = GPM
320 400
Maximum operating pressure = 5000 psi
Will accept maximum pressure at Port 2.
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Maximum operating pressure = 350 bar
Factory pressure settings established at 4 GPM
Maximum leakage at shutoff = 0,4 cc/min. at 350 bar
Typical
time=10
Effectiveresponse
orifice size
0,9ms.
mm
3
Maximum
leakage
=
RPCC,
RPEC:
2 in 3closed
/min./1000
psi,open
RPGC:
Number
of
counterclockwise
turns fully
to fully
= 3 3 in /min./1000 psi, RPIC: 4
3/min./1000 psi, RPKC: 5 in3/min./1000 psi.
in
Ports 1 and 2 may be pressured to 350 bar.
RPCC minimum setting for all spring ranges is 75 psi
■
■
■
■
■
■
■
■
■
■
■
■
OPTION ORDERING INFORMATION
Model Codes printed in Red are Preferred Versions and most readily available
RP
N ✱
FC
A –
B ✱– ✱K ✱X ✱
Nominal
Capacity
Model
C
Code
12 GPM*
Control**
Adjustment Range
Control
Maximum Orifice
$ 31.90
L Standard Screw
NFAB-KXN
E
25 GPM
$ 36.20
G
50 GPM
$ 51.80
I
100 GPM
K
200 GPM
+$ 0.00
Seal
Seal
A 100 - 3000 psi
+$ 0.00
N Buna-N +$ 0.00
K Tamper
Handknob
C
Resistant +$ 4.10
X 50
0,9-mm
B
1500 psi
+$ 0.00
N Viton
Buna-N +$ 2.00
V
K Handknob
C 150 - 6000 psi
+$ 2.00
$ 97.30
N 60 - 800 psi
+$ 1.00
$187.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
+$ 5.00
** See page 162 for information
on Control Options
V Viton
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
* Minimum setting 75 psi on all ranges.
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
132
UK Shortcut Catalogue #999-901-244
Pilot Control Valves
ELECTRO-PROPORTIONAL PILOT RELIEF
Relief Valves
PILOT OPERATED, BALANCED PISTON
Full Adjustment 5 Turns
+
-
2
1
2
1
d
c
Cartridg
b
Capacity
Locating
c
Locating Shoulder
1 L/min.
Shoulder
a
Capacity
a
Inlet 1
12 GPM
2
Outlet
Performance Curves
Inlet 1
RPEC – LAN
T - 10A
1.56
7/8”
2.00
2.06
2.25
30/35
T - 3A
1.88
1 1/8”
2.12
2.18
2.38
45/50
100 GPM
RPIC – LAN
T - 16A
2.44
1 1/4”
2.44
2.47
2.69
150/160
200 GPM
RPKC – LAN
3.13
1 5/8”
2.81
2.94
3.06
350/375
RBAP
T - 18A
P = bar
276
RPGC
200
Pressure vs. Command
Flow 0,37 L/min.
276
RPIC
200
5000
5000
4000
4000
Flow/min.
4000
Command (%)
3000
3000
3000
0
5
10
15
Flow = GPM
20 ■ 25
■
■
■
■
■
■
■
■
■
■
■
■
■
.50
1.00
2000
1.50
1.98
0
20
40
60
P = psi
0
P = psi
P = psi
4000
■
RPKC
Typical Pressure
Rise
100
100
5000
1000
d
RPGC – LAN
5000
2000
c
50 GPM
RPEC
3000
b
25 GPM
Performance Curves
P = psi
a
T - 8A
RBAP – MAN
Typical
Cartridge
Cavity
a
Model Code
T - 162A
1.22
RPCC – LAN
Constant Command
Varying Flow
RPCC
mensions
2000
80
5000
100
P = psi
2
Outlet
e Di
Installation
Torque
(Nm)
18,8 Cartridge
22,2 Dimensions
15,0
70,1
35/40
c
Installation
b
Torque
L
C
K
(lb. ft.)
3/4”
2.11
2.17
2.31
25/30
Cavity
P = bar
b
Typical
Cartridge
Model Code
2000
4000
3000
2000
1000
1000
1000
Maximum
operating pressure1000= 350 bar
0
40
80
120
160 200
0
80
160
240
320
0
20
40
60
80
100
0
10
20
30
40
50
Maximum leakage = 24,6 cc/min at Flow
reseat
Flow = GPM
= GPM
Flow = GPM
Flow = GPM
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting
Maximum operating pressure = 5000 psi
Reseat exceeds 85% of crack
Will accept maximum pressure at Port 2.
Hysteresis with dither <4%
Back pressure on the tank port (port 2) is directly additive at a 1:1 ratio to the valve setting.
Hysteresis with DC input <8%
Factory pressure settings established at 4 GPM
Linearity with dither <2%
Typical response time 10 ms.
For optimum performance, an amplifier with
current sensing and adjustable
dither should be used.
Maximum
leakage
= RPCC,between
RPEC: 2100
in 3/min./1000
psi, RPGC: 3 in3/min./1000 psi, RPIC: 4
Dither
should
be
adjustable
250
Hz.
in3/min./1000 psi, RPKC: 5 in3/min./1000 psi.
RPCC minimum setting for all spring ranges is 75 psi
OPTION ORDERING INFORMATION
400
Model Codes printed in Red are Preferred Versions and most readily available
RP ✱
RB
AC
P – ✱ ✱✱
Nominal
Nominal
Capacity
Capacity
C 12 GPM*
A 1 L/min.
E 25 GPM
$ 31.90
G
$ 51.80
50 GPM
Control**
Control**
$ 36.20
I
100 GPM
$ 97.30
K
200 GPM
$187.00
L Standard Screw +$ 0.00
M Manual Override
C Tamper
Resistant +$ 4.10
(Standard)
K Handknob
+$ 5.00
NOTE: Coil must be
ordered separately. Use
12V DC or 24V DC
(Series 770-***) coils
only. See page 167.
Adjustment
Adjustment Range
Range
A
A
B
B
C
100 - 3000 psi
20 - 210 bar
50 - 1500 psi
10 - -105
barpsi
150
6000
+$ 0.00
+$ 0.00
+$ 2.00
N
W 60
35 - 800
350 psi
bar
+$ 1.00
Q 60 - 400 psi
+$ 1.00
W 150 - 4500 psi
+$ 0.00
Seal
Seal
N
N
V
V
Buna-N +$ 0.00
Buna-N
Viton
+$ 2.00
Viton
Adjustment Range Options:
A, B, C, and W are standard set at 1000 psi.
N Option is standard set at 400 psi.
Q Option is standard set at 200 psi.
** See page 162 for information
* Minimum setting 75 psi on all ranges.
on Control Options
Customer may specify pressure setting.
+$ 1.10
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
133
Visit www.sunhydraulics.com for detailed and complete technical information on our full line of products.
6
US Shortcut Catalogue #999-901-243
UK Shortcut Catalogue #999-901-244
Pilot Control Valves
NOTES
134
UK Shortcut Catalogue #999-901-244
Download