SSR ® UP Series Ref: Sheet Date: Cancels: 9904 25 15 January 2003 First Issue Point of Manufacture – Unicov, Czech Republic SSR® UP5-11, 15, 18, & 22, FUNCTIONAL SPECIFICATION (INTELLISYS) LCD Display (1) Displays compressor status, set up parameters, and gives warning/alarm messages. When the compressor is running the display will normally show package discharge pressure. automatically provided the controller detects a demand for air. When pressed in, the display mode will cause exit to ‘CHECKING MACHINE’ for 2 seconds, then ‘READY TO START’. Display Select (2) Is used to select alternative status displays (after approx. 5 minutes the display defaults to package discharge pressure). Pressing this button in the SET POINT ROUTINE will cause exit to ‘CHECKING MACHINE’ for 2 seconds, then ‘READY TO START’. Unloaded Stop (7) When pressed while compressor is running will unload the compressor (if not already unloaded) for 10 seconds and then stop. This is the normal method for stopping the compressor. If compressor is already stopped will execute an LED check (all LED’s should illuminate) and display controller software revision. Up arrow/down arrow (3) Is used to index through warning and alarm messages. In the set point routine these buttons are used to increment/decrement set point values, enable/disable some operation conditions and toggle between pressure range. Set (4) Pressing this button will allow entry into the set routine. Once in the set point routine this button will cause the controller to move onto the next set point saving the new value if one has been entered. A warning reset is obtained by pressing this button (while the machine is running). An alarm reset is obtained by pressing this button twice within 3 seconds (the alarm condition will remain if the indicated fault has not been rectified). Load/unload (5) Is used to manually switch the compressor between a loaded control mode (e.g. on/offline) and unloaded running. Start (6) When pressed will cause the compressor to start and load Loaded Hours (15) Will illuminate when display indicates total unloaded compressor hours. Load/unload (16) Will illuminate when compressor is running onload. Modulation (17) Will illuminate when compressor is running in modulation mode. (NB Capacity modulation will only occur if appropriate regulation pneumatics are fitted to the compressor). Emergency Stop (8) When depressed will stop the compressor immediately and display ‘EMERGENCY STOP’ alarm message. Unload (18) Will illuminate when the compressor is running in unload mode. Power (9) Will illuminate when 8 volt controller supply is available. Automatic Restart (19) Will illuminate when the machine has shut down due to low air demand. The compressor will restart and load automatically as soon as pressure falls below the cut in pressure. Package discharge Pressure (10) Will illuminate when display indicates package discharge pressure. Airend Discharge Temp. (11) Will illuminate when display indicates airend discharge temperature. Sump Pressure (12) Will illuminate when display indicates sump pressure. Separator Pressure Drop (13) Will illuminate when display indicates separator pressure drop. Total Hours (14) Will illuminate when display indicates total compressor running hours. Alarm (20) Will flash when a warning condition exists, the warning detected will be displayed. The compressor will continue to run. A warning can be reset, by pressing "Set". (4). Will illuminate solid when an alarm condition has occurred. Compressor will shut down immediately. An alarm can be reset, by pressing "Set" (4) twice within 3 seconds. SSR Ref: Sheet Date: Cancels: ® UP Series 9904 26 15 January 2003 First Issue Point of Manufacture – Unicov, Czech Republic SSR® UP5-11, 15, 18, & 22, FUNCTIONAL SPECIFICATION (INTELLISYS) Other LED’s Will illuminate during the set point routine to indicate which function is being adjusted. DISPLAY MESSAGES When the compressor is running normally the display will indicate package discharge pressure and illuminate the corresponding LED (10). Pressing Display Select (2) will change the display value and the corresponding LED will illuminate. The controller monitors all aspects of the compressor whilst running and will display warnings or in severe conditions stop the machine and display alarm conditions. Warnings In the event of a warning the controller will display a message and the alarm LED (20) will flash. The warning message will alternate with the normal display every 4 seconds, the compressor will continue to run but the fault should be rectified as soon as possible. The arrow keys (3) should be used to index the display for any additional warning messages. A warning message may be reset by pressing set (4) once. Note: the warning will reoccur if the fault has not been rectified. The following warning messages may be displayed. Separator Element The separator element is blocked/ruptured and should be replaced. Service Indicates a service due warning on the display every 3000 hours. Alarms In the event of an alarm the controller will execute a protection stop. The alarm LED (20) will illuminate and an alarm message will be displayed. The arrow keys (3) should be used to index the display for any additional alarm message. An alarm is reset, by pressing set (4) twice, within a 3 second period after the fault has been rectified. The compressor will only restart once all alarm conditions have been rectified. The following alarm messages may be displayed. Starter Fault Contactor sequence during start or stop is incorrect. Airend Discharge Temperature The airend discharge temperature is above the high temperature set point (std. 109ºC or 228ºF). Motor Overload The motor overload contacts are opened. The motor overload must be reset before the controller can be reset. Reverse Rotation No sump pressure is detected after the first 2 seconds of running. This is an installation fault indication and should only be dealt with by a qualified service engineer. Machine must be isolated and polarity of mains connections checked before resuming. Low Sump Pressure When sump pressure is less than 1bar (14.5 psig) the machine will stop. Over Pressure Line pressure is 1 bar (14.5 psig) greater than rated discharge pressure. Pressure Sensor Malfunction The pressure transducer/connecting cable has failed. Temp Sensor 1 The airend temperature sensor or connecting cable is faulty. Failed Calibration During calibration routine, a 10% off scale error has been detected, ensure separator is completely blown down and repeat calibration. Control Power Failure The 110vAC signal is not present at the controller (e.g. blown fuse) Emergency Stop The emergency stop button is pressed. Remote Start Failure Momentary remote start has not disengaged before star-delta transition. This alarm is only active if remote Start/Stop is enabled. Remote Stop Failure Momentary remote stop switch has not disengaged when start signal is received. This alarm is only active if remote Start/Stop is enabled. SSR Ref: Sheet Date: Cancels: ® UP Series 9904 27 15 January 2003 First Issue Point of Manufacture – Unicov, Czech Republic SSR® UP5-11, 15, 18, & 22, FUNCTIONAL SPECIFICATION (INTELLISYS) SET POINTS Customer Set Points With UP series software the customer set points can be viewed and adjusted within permitted range whilst the compressor is in operation. Off line Pressure Pressure at which the compressor will unload eg, 7.5 bar (109 psig) Online pressure Pressure at which the compressor will load. Commissioning Set Points Star - Delta Time Varies the delay transition time from star to delta (eg; 5 seconds). Language Select display language. Programmed to display in twelve different languages. Auto - Restart Time Varies the unloaded run on time before the compressor shuts down (2 minutes minimum). Units of Measure Select a combination of units of measure; The machine will run for a minimum of 10 minutes from start up in order to ensure protection against excessive start / stop cycles. BAR AND DEGREES C PSI AND DEGREES C KPA AND DEGREES C PSI AND DEGREES F KG/CM2 AND DEGREES C Rated Discharge Pressure Dual Pressure Set points Sequence control The UP Series software allows the user to set two different online & off-line pressures. The user can then toggle between the two settings by pressing the up & down arrows. This feature gives the user the ability to simply sequence two machines by biasing the two pressures. Energy Reduction When reduced system pressure can be accepted under certain conditions, and having set the ranges appropriately, the user can toggle between the two pressure bands and operate at a lower pressure when appropriate to save energy cost. Control Mode Select the following modes of capacity control. On/off line, or Modulation / ACS. (if modulator option fitted) Sequencer On/Off Enables the sequencer interface of sequencer chip if fitted. Remote Start On/Off Enables remote start interface. A remote switch circuit must be connected. Load Delay Timer Varies the delay before the compressor will load following a request to load. Can be used to reduce excessive system cycling (factory set to 0 sec). P.O.R.O If the optional Power Out Restart feature is fitted, the customer can enable or disable this feature. Select package pressure eg 8.5 bar (123 psig). Used in the case of pressure conversion ie, drive ratio change Temperature Trip Point Select airend discharge trip temperature eg typically 100 109ºC (212- 228ºF) selectable range. LCD Contrast Varies display contrast.