Vante® PIRF® II Catheter Manufacturing System

advertisement
PIRF II
®
Vante®
Catheter Manufacturing System
• The Vante PIRF® II system, utilizing precision energy
control and heat placement, is specifically designed for
small profile catheter manufacturing.
• A proprietary mold design concentrates heat to an area
as small as 1mm for tipping and butt weld applications.
• The temperature control and precise heat placement of
this system are especially critical in controlling flash
and achieving quality welds of braided materials as well
as materials with significant durometer differences.
• The Vante PIRF® II system consists of a model 3220 RF
generator and one of three forming platforms, depending
on requirements of the specific application.
• All platforms can be teamed with a variety of tipping,
welding, and forming molds for different applications.
• This product has been sunsetted and is therefore made
to order and available for existing customers only.
RF Generator 3220
PIRF® II’s numerous features include:
RF Generator with easy front panel programming.
·Air cooled/no water chillers
·Closed loop temperature feedback
· Operator safe so there are no hot spots or pinch points
·Semi-automated
·High and low force platforms
·Easy front panel programming
·Low friction pneumatic air cylinders and slides
·Precise heat placement
·Proprietary low mass mold design
·Solid-state circuitry
·Temperature repeatable to + 1°C
Forming Platform 3226
Features standard insertion force and standard gripping force.
Forming Platform 3227
Features low insertion force and standard gripping force.
Forming Platform 3228
Features standard insertion force and high gripping force.
PIRF® II’s numerous applications include:
·Taper Tips
·Radius Tips
·Soft Tips
·Closed End Tips
·Dilator Tips
·Flaring
·Neck Downs
·Butt Welds
·Overlap Welds
·Braid to Non-Braid Welds
·Single/Multilumen Applications
·Balloon Tips and Welds
·Marker Band Embedding/Placement
·Specializing in Custom Application
PIRF® II’s numerous benefits include:
·Compact footprint which saves cleanroom space
·Repeatable, high quality results
·Easy to set up and validate
·Quantifiable and validatable process
·High production first pass yields
·Quick and easy tooling change
CATHETER MANUFACTURING
PIRF II
®
Vante
MECHANICAL SPECIFICATIONS
3200
3226 / 3227
3228
Dimensions
17.75 x 14 x 4 in
12 x 8.5 x 2.5 in
10 x 8 x 4 in
(W x L x H)
(44.5 x 35.5 x 10 cm)
(30.5 x 21.5 x 6 cm)
(26.6 x 21.5 x 10.1 cm)
Operating Weight
20 lbs (9.1 kg)
7 lbs (3.2 kg)
6 lbs (2.7 kg)
Shipping Weight
24 lbs (10.9 kg)
8 lbs (3.6 kg)
7 lbs (3.1 kg)
Maximum Air Supply
—
90 psi
90 psi
Number of Slides
—
Two Slides
Two Slides
Slide Insertion Force
—
9.3 lbs @ 30 psi for 3226
9.3 lbs @ 30 psi
—
3.2 lbs @ 30 psi for 3227
—
5 lbs @ 70 psi
18 lbs @ 90 psi-4 lbs @ 20 psi
100 VAC 50/60 Hz
—
—
115 VAC 50/60 Hz
—
—
230 VAC 50/60 Hz
—
—
RF Power Output
90-150 Watts
—
—
Radio Frequency Output
40.68 MHz
—
—
User Interface
IDEC® MicroSmart® HMI
—
—
Process Parameters Storage
1 Standard, 2 Optional
—
—
Internal Circuit Protection
Yes
—
—
Use
Indoor use only
Indoor use only
Indoor use only
Temperature
50 - 85°F (10 - 30°C)
68 - 95°F (20 - 35°C)
68 - 95°F (20 - 35°C)
Humidity
Non-Condensing
Non-Condensing
Non-Condensing
Over-voltage Category
II
II
II
Pollution Degree
2
2
2
Altitude
Up to 2000 meters
Up to 2000 meters
Up to 2000 meters
Grip Force
ELECTRICAL SPECIFICATIONS
Power Input
PERFORMANCE FACTORS
OPERATING CONDITIONS
Vante | 100 N. Tucson Boulevard, Tucson, Arizona 85716 USA | Toll-free 877.565.5557 | 5 20.881.6555 | Fax 520.326.0863 | vante.com