Notifier by Honeywell: Emergency Voice Communication Systems (EVCS) Notifier by Honeywell: EVCS Committed to Life Safety for all An EVCS (Emergency Voice With access provided for all, provision suitable areas for refuge and the type of Communication System) or Disabled must be made for safe evacuation in construction, the Standard specifies the Refuge System is designed for use in the event of an emergency. In some need for two way communication. buildings that contain refuge areas. circumstances, those with physical This type of intercom system allows impairments can be assisted by others – emergency services to be in constant but in many situations this is not suitable contact with the people in the refuge or safe. areas who seek assistance. The Equality Act (formerly The Disability Discrimination Act) made it the responsibility of all companies, nationwide, to ensure that access to buildings and services is available to everyone – there must be no discrimination. An EVCS allows firefighters and others to communicate with one another during emergency situations. The system also allows communication with disabled A solution comes in the form of temporary persons. It is a “system that allows areas of safety – ‘refuge areas’. The voice communication in either direction person in need of assistance is helped between a central control point and a to the closest refuge area and awaits number of other points throughout a safe evacuation. Refuge areas must building or building complex, particularly meet certain criteria: these are covered in a fire emergency situation” in BS9999:2008. As well as describing (BS5839-9:2011 3.4). Please find below an extract from the British Standard for your reference BS 5839-9:2011 commissioning and maintenance of Mobile telephones and two-way radio sets emergency voice communication (EVC) are therefore not within its scope. Voice systems in and around buildings and at alarm systems are primarily intended for sports, entertainment and similar venues. the automatic broadcasting of evacuation It ensures that high standards of reliability, messages are excluded from this code of safety and security are achieved, practice. This British Standard does not together with acceptable standards recommend whether or not an emergency Executive summary of performance. This code of practice voice communication system should be primarily relates to the use of EVC in installed in a given premises. This part assisting both firefighters and those of BS 5839 does not cover systems Recommendations for the planning, responsible for evacuating buildings or combining electrically the functions of design, installation, commissioning sports stadia in fire emergency situations, EVC systems with functions of other fire- and maintenance of emergency voice including evacuation of disabled persons. related or non-fire-related systems. communication systems in buildings. Use, other than in fire emergency Abstract situations, by disabled persons and This British Standard, a part of the BS addressed in detail. Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems. 5839 series, provides recommendations for the planning, design, installation, others, although not precluded, is not In the context of this code of practice, an EVC system contains no portable parts. This part of BS 5839 applies only to emergency voice communication systems for use in a temperate climate such as that of the United Kingdom. Notifier by Honeywell: Fire Systems Equality Act made it the responsibility The Notifier“The Solution of allworks companies, nationwide, to ensure with a network of fire installation, Flexible, Expandable, and maintenance require, large or small, we offer the that commissioning access to buildings and services is Backward Compatible companies, who have completed a same professional approach and a comprehensive programme, – andthere must be no straightforward way of working. Everyavailable to training everyone Lifetime cost of ownership is often have direct access to extensive product, business is unique and we ensure that overlooked when selecting a fire alarm discrimination.” technical and application support. So, you get the system that is right for you. and detection system. Scheduled Whatever fire alarm system you We have the flexibility to adapt to your when it comes to installing a system in changing circumstances and, as your buildings with specific requirements you requirements evolve, Notifier remains can be confident you are working with committed to offering the best service a company with the experience and standards and a level of care that sets us expertise to meet the challenge. apart from our competitors. We provide the highest quality and most complete product line; prompt on-time delivery and competitive pricing. Notifier maintenance, system testing and changes necessary to meet the evolving needs of your business can add significant costs. The proven reliability of our systems is backed by our commitment to support and backward compatibility. So, by choosing a Notifier system you can be confident of choice, flexibility and value for money throughout the lifetime of the system. Notifier by Honeywell: EVCS The Compact 9 System The Compact 9 System is ideal for small to medium sized installations which don’t require the complexity of a full network solution. This system comprises of the 9 Line Typical System Architecture: Key features: Master Exchange Unit and up to The Compact 9 Line Master Exchange l 9 Outstations (Type A, Type B, or Unit is a self contained enclosure housing Emergency Assist Alarms). Using the 10 l a Master Handset, 9 Line Exchange, line Slave Exchange Unit this system can l power supply, and battery charger. It can be easily expanded to 19 lines. be surface or semi-flush mounted as The Compact 9 is modular in design standard. l l l and the controller manages all functions for the first 9 zones. There is no need for additional equipment such as power supplies. BS5839 part 9 (2011) compliant 4 navigation keys 6 status LED’s 4 line, 20 character LCD Simple menu programming Contact outputs to interface with Fire Detection or Voice Alarm Systems Benefits: l l l Using the 10 Line Exchange unit extends the system to 19 communication lines In addition to Type A and Type B Outstations it can also monitor Emergency Assist Alarms (using a 2 core radial) Connection between the exchange unit and slave is achieved using standard 4 core fire rated cable Notifier by Honeywell: EVCS The Network 8 System The Network 8 EVCS modular architecture is ideal for use in larger buildings with up to 256 communications zones. Suitable for use in high rise buildings as well as large complexes such as schools and universities. The Network 8 System greatly reduces Key features: the cabling requirement and equipment l ‘on view’ in such key places as reception areas, making the system much more aesthetically pleasing to the customer as l well reducing the cost of installation. l Typical System Architecture: The system is controlled by the Network l Master Handset. It is possible to add up l to 7 additional master handsets allowing the Network 8 to deliver a highly flexible emergency management strategy. l Larger systems are built using a series of Exchange Units connected to a loop network providing cost effective and secure installations. l Each Exchange can control up to 8 independent monitored lines Controls up to 256 Lines (32 exchanges) Built in monitored 1A battery charger 12 status LEDs Dry contact for fault or “in-use” indication Serial port for configuration or updates Dual network ports which provide power for the master handsets Benefits: l l l l l l Clear LED indication on the Exchange Unit for effective & easy fault finding Can be easily connected to a fire panel or BMS Upload information quickly via a PC using the serial port Distributed system architecture, no central exchange rack required In addition to Type A and Type B Outstations the Compact 5 Line Exchange Unit can also monitor Emergency Assist Alarms No programming required, simply connect the Outstations and the system is ready to work Notifier by Honeywell: EVCS Type A Outstation The Type A Outstation is compatible with all EVCS systems for use as a standard Fire Telephone or Disabled Refuge call point. The Type A Outstation is a compact unit Key features: which offers easy access via a magnetic l push catch door. The flush mountable unit offers a unique front levelling system allowing the back box to be mounted at a slight angle whilst still retaining a true l l l front face and door. A surface mountable unit is also available. l l Fire telephones are hardwired full duplex communications systems with monitoring and battery backup, and are required in buildings over 4 stories in many countries in the world (in the UK this is governed by BS 9999). These are provided as a backup to traditional fireman’s radio systems, which can fail to operate in many high rise environments due to the large amount of steel in the building, and the “corona” effect of fire on radio broadcasts. Compact design High volume ringer Status LED Telecoil for hearing impaired users Full duplex operation Automatic dialling when ‘off hook’ Benefits: l l l Can be used on all Gent EVCS systems providing compatibility across the range Can be used as a fire telephone or a disabled refuge call point Magnetic push catch, lockable door Notifier by Honeywell: EVCS Type B Outstation The Type B Outstations are designed to be versatile, compact and provide an easy to use refuge call point. All Type B Outstations are defined in BS Key features: 5839 part 9 and can be used as a Fire l Telephone or Disabled Refuge call point. l The Type B Outstation is available in red, green and stainless steel. Tactile braille l signage assists partially sighted people to easily operate the Refuge Point. l l l Compact design Loop output for hearing impaired users Full duplex operation, allowing 2 way voice communication High volume ringer Status LED Flush bezel available Benefits: l l l Can be used on all EVCS systems Full duplex operation, allowing 2 way voice communication Tactile braille signage to assist partially sighted people enabling them to easily operate the refuge point Choosing outstation type 11.1.a 11.1.b When choosing the Outstation type An outstation intended for evacuation or An outstation intended for use by disabled for use with an EVCS we recommend firefighting use should be Type A. A Type people at refuges may be either Type A reading section 11 of BS 5839 9:2011 B outstation should be used for such or Type B. However, Type B outstations which deals with Outstation Types and purposes only where it is impractical to should be used in situations where the states as follows: install a Type A outstation. outstation will be operated by members of the public. Notifier by Honeywell: EVCS Emergency Assist Alarm Range The Emergency Assist Alarm Kit has been specifically designed to integrate disabled call functions into the EVCS network or EVCS compact ranges providing the perfect solution for conformity with the Building Regulations Document M and Equality Act 2010. It has now become very common for the The Emergency Assist Alarm Kit shows l disabled toilet to be specified as part of up as a call on the EVCS system, but has l the refuge system. no speech path so a conversation cannot l Disabled toilet alarms are required by Building Regulation Document M, and by integrating it with the Emergency Voice Communication System all calls relating to disabled communications can be be had with the occupant, use of the Type B Outstations would allow this. Power Supply - 12V + Pull Cord Unit displayed in a single point. + + IN + OUT l Typical System Architecture: The Emergency Assist Alarm Kit solution is fully monitored and battery backed by the EVCS system, saving local power supplies and giving confidence in the Key features: l l system integrity. l Benefits: Over Door Indicator IN + + OUT Monitored to BS 5839 9 Remote powered from EVCS exchange Dual loop pull cord High contrast labels Braille on ‘cancel’ button Blue indication Cancel l Unit l l Saving power, no PSU is required remote powered by EVCS system One install saves running 2 separate systems Calls from either disabled toilets or refuge points are monitored from one central location Tactile braille signage to assist partially sighted people to easily operate the ‘cancel’ button Notifier by Honeywell: EVCS 4 Way Splitter Unit The 4 Way Splitter Unit allows up to 4 stand alone disabled toilets to be monitored in one specific area. Extend your Emergency Assist Alarm Key features: Stand Alone Unit by adding a 4 Way l Splitter Unit. Staff can then, at a designated area, such as a reception or security desk monitor l and react to an alarm in four separate l disabled toilets swiftly and efficiently, from one easy to use and space saving device. Typical Architecture: l Designed to comply with all regulations and recommendations High visibility More than one 4 way splitter can be used Small compact design Benefits: l l l l Up to 4 disabled toilets monitored in one area Uses blue LEDs to avoid confusion Visibility to remote staffed areas No mains or Power Supply Unit (PSU) required at each disabled toilet Notifier by Honeywell: Fire Systems Safety, Integrity and Heritage Notifier by Honeywell is the world’s quality fire detection and alarm control manufactured to meet every major largest manufacturer and supplier of solutions. These include everything from international approval, including LPCB, engineered fire alarm systems. With over smoke detection and notification, non- VdS, UL, ULC and BOSEC/ANPI. 400 Engineered Systems Distributors addressable fire alarm panels, analogue worldwide, and regional support on addressable systems, to advanced every continent, we have the flexibility network and integration packages. As a to meet our customers’ requirements. leader in the fire safety market, Notifier With over 50 years of experience, we is dedicated to the highest standards offer unrivalled specialist knowledge and of service and product quality. Our products designed to meet all needs. operations are accredited to ISO 9001 Notifier offers a comprehensive line of and our products are designed and Notifier is a division of Honeywell International, a diversified technology and manufacturing leader, serving customers worldwide. By partnering with Notifier, you have the reassurance of working with a company of global standing that provides cutting edge fire detection systems. Caburn House Brooks Road Lewes, E. Sussex BN7 2BY T: +44 (0) 1273 897 000 F: +44 (0) 1273 376 894 E: sales@notifierfiresystems.co.uk www.notifierfiresystems.co.uk local distributor NFR0060_EN_A_0415 Visit www.notifierfiresystems.co.uk to find your local distributor.