TriStar MPPT Meter Map

advertisement
Models:
TS-MPPT-45
TS-MPPT-60
Solar Charging
Battery Voltage / Temp. / Current
Ah resettable / Charge State
Operating
Displays
Battery Voltage Graph
Battery Current Graph
13.5V 25C 12.3A V
1234.5Ah
FLOAT A
Reset Ah
(Hold  2 sec)
Manual
Operations
Battery Max. / Ah Total Counter Battery Voltage / Temp. / Watts
Battery Min. / kWh Total Counter kWh resettable / Charge State
14.4V
12.3V
Battery Voltage / Temp. / Watts Battery Voltage / Temp. / Current
Battery Watts / Charge State
Daily Watt-hours / Charge State
11357AhT 13.5V 25C 367W 13.5V 25C 367W 13.5V
FLOAT 32565 Wh
11.3kWhT 123 kWh
FLOAT 367W
25C 12.3A
FLOAT
( to Return)
Diagnostics
Clear Resettable Ah / kWh Counters
Clear Battery Max. / Min. Voltages
Faults:  1
Equalize START
(Hold  2 sec)
Diagnostics
( to Return)
TriStar Settings
TS-60 v01.01.01 TriStar HW / SW Version
Serial: 09250001 Controller Serial Number
Meter v01.01.01
Equalize Start / Stop
Diagnostics
(Press  )
TriStar
Settings
Meter HW / SW Version
TriStar Settings
(Press  )
View Logged
Data
Logged Data
(Press  )
(Hold 3 seconds)
Modify
Settings
Advanced Setup
(Press  )
( to Return)
Advanced Setup
Meter addr
Adjust the
MeterBus Address      2

Mode:
Charge
12V (Auto)
Battery #: 4
Float:
13.70V
Absorption:
14.40V
MPPT
Equalize: 15.15V
Automatic
28d
Language
English 
Units:
°C

TriStar Mode of Operation
System Voltage
Battery Type (see manual)
Float Charge Voltage
Absorption Charge Voltage
Regulation Type
Equalize Charge Voltage
Days Between Eq. Charges
Meter Display Language
Meter Display
Temperature Units
of
1
HVD
Alarms:
NONE
Battery:
24° C
14.35V
12.44A
Battery Sense
14.40V
valid
State:
FLOAT
Solar:
17.70V
Last Eq:
12d
total:
23547Ah
Reset: 1234.5Ah
TriStar:
35°C
123456 hours
Battery Service
17d (  2s reset)
Reset Ah Total
(Hold  2 sec)
Faults List
Alarms List
Battery Temperature
Battery Voltage / Current
Battery Sense Voltage
Charge State
Solar Input Voltage
Days Since Last
Equalization
Total Ah Counter
Resettable Ah Counter
TriStar Heatsink Temperature
Cumulative Hours of Service
Days Since Last
Battery Service Reminder
Clear Total Ah / kWh Counters
( to Return)
Logged Data
Today:
Battery
51.2 Vmax
Today:
Battery
45.5 Vmin
Today:
Battery
1234.5 Ah
Day: -01 Battery
51.2 Vmax
Day: -01 Battery
45.5 Vmin
Day: -01 Battery
1234.5 Ah
Day:-XXX Battery
51.2 Vmax
Day:-XXX Battery
45.5 Vmin
Day:-XXX Battery
1234.5 Ah
Today:
Faults
Day:
Alarms
Day:
Day:-XXX
Faults
NONE
Day:-XXX
Alarms
NONE
NONE
Today:
NONE
Today’s Data
-01
Faults
NONE
-01
Alarms
NONE
Yesterday’s Data
Data X Days Ago
TriStar MPPT Alarms & Faults Lists
Alarms
Description
Faults
Description
Ths Disconnected
heatsink temp. sensor is open
External Short
external short circuit
Ths shorted
heatsink temp. sensor shorted
Overcurrent
current exceeds rating
TriStar HOT
limiting current due to high temp.
FET Short
power switches may be damaged
Current limit
limiting an overcurrent condition
Software
software problem
Current offset
current measurement off > 1 Amp
HVD
high voltage disconnect
Battery sense
battery voltage sense error
TriStar HOT
heatsink temperature exceeded limits
Batt Sense disc
battery sense no longer connected
DIP sw changed
Uncalibrated
controller not factory calibrated
a settings switch was adjusted while
running
RTS miswire
sense wires are connected to RTS
Setting Edit
new setting(s) written to custom
settings memory
miswire
system wiring problem detected
Reset?
a reset due to an interrupted fault
FET open
power switches not turning on
Miswire
system wiring fault
P12
internal power supply problem
Slave Timeout
no slave control information received
for over 1 minute (slave mode only)
8 Pheasant Run
Newtown, PA 18940 USA
info@morningstarcorp.com
www.morningstarcorp.com
YOUR DKZE/E'^dZDISTRIBUTOR
SOLIGENT
800-967-6917
www.soligent.net
MS-ZMAN-TSM2-04-B
Download