Models: TS-MPPT-45 TS-MPPT-60 Solar Charging Battery Voltage / Temp. / Current Ah resettable / Charge State Operating Displays Battery Voltage Graph Battery Current Graph 13.5V 25C 12.3A V 1234.5Ah FLOAT A Reset Ah (Hold 2 sec) Manual Operations Battery Max. / Ah Total Counter Battery Voltage / Temp. / Watts Battery Min. / kWh Total Counter kWh resettable / Charge State 14.4V 12.3V Battery Voltage / Temp. / Watts Battery Voltage / Temp. / Current Battery Watts / Charge State Daily Watt-hours / Charge State 11357AhT 13.5V 25C 367W 13.5V 25C 367W 13.5V FLOAT 32565 Wh 11.3kWhT 123 kWh FLOAT 367W 25C 12.3A FLOAT ( to Return) Diagnostics Clear Resettable Ah / kWh Counters Clear Battery Max. / Min. Voltages Faults: 1 Equalize START (Hold 2 sec) Diagnostics ( to Return) TriStar Settings TS-60 v01.01.01 TriStar HW / SW Version Serial: 09250001 Controller Serial Number Meter v01.01.01 Equalize Start / Stop Diagnostics (Press ) TriStar Settings Meter HW / SW Version TriStar Settings (Press ) View Logged Data Logged Data (Press ) (Hold 3 seconds) Modify Settings Advanced Setup (Press ) ( to Return) Advanced Setup Meter addr Adjust the MeterBus Address 2 Mode: Charge 12V (Auto) Battery #: 4 Float: 13.70V Absorption: 14.40V MPPT Equalize: 15.15V Automatic 28d Language English Units: °C TriStar Mode of Operation System Voltage Battery Type (see manual) Float Charge Voltage Absorption Charge Voltage Regulation Type Equalize Charge Voltage Days Between Eq. Charges Meter Display Language Meter Display Temperature Units of 1 HVD Alarms: NONE Battery: 24° C 14.35V 12.44A Battery Sense 14.40V valid State: FLOAT Solar: 17.70V Last Eq: 12d total: 23547Ah Reset: 1234.5Ah TriStar: 35°C 123456 hours Battery Service 17d ( 2s reset) Reset Ah Total (Hold 2 sec) Faults List Alarms List Battery Temperature Battery Voltage / Current Battery Sense Voltage Charge State Solar Input Voltage Days Since Last Equalization Total Ah Counter Resettable Ah Counter TriStar Heatsink Temperature Cumulative Hours of Service Days Since Last Battery Service Reminder Clear Total Ah / kWh Counters ( to Return) Logged Data Today: Battery 51.2 Vmax Today: Battery 45.5 Vmin Today: Battery 1234.5 Ah Day: -01 Battery 51.2 Vmax Day: -01 Battery 45.5 Vmin Day: -01 Battery 1234.5 Ah Day:-XXX Battery 51.2 Vmax Day:-XXX Battery 45.5 Vmin Day:-XXX Battery 1234.5 Ah Today: Faults Day: Alarms Day: Day:-XXX Faults NONE Day:-XXX Alarms NONE NONE Today: NONE Today’s Data -01 Faults NONE -01 Alarms NONE Yesterday’s Data Data X Days Ago TriStar MPPT Alarms & Faults Lists Alarms Description Faults Description Ths Disconnected heatsink temp. sensor is open External Short external short circuit Ths shorted heatsink temp. sensor shorted Overcurrent current exceeds rating TriStar HOT limiting current due to high temp. FET Short power switches may be damaged Current limit limiting an overcurrent condition Software software problem Current offset current measurement off > 1 Amp HVD high voltage disconnect Battery sense battery voltage sense error TriStar HOT heatsink temperature exceeded limits Batt Sense disc battery sense no longer connected DIP sw changed Uncalibrated controller not factory calibrated a settings switch was adjusted while running RTS miswire sense wires are connected to RTS Setting Edit new setting(s) written to custom settings memory miswire system wiring problem detected Reset? a reset due to an interrupted fault FET open power switches not turning on Miswire system wiring fault P12 internal power supply problem Slave Timeout no slave control information received for over 1 minute (slave mode only) 8 Pheasant Run Newtown, PA 18940 USA info@morningstarcorp.com www.morningstarcorp.com YOUR DKZE/E'^dZDISTRIBUTOR SOLIGENT 800-967-6917 www.soligent.net MS-ZMAN-TSM2-04-B