TriStar Meter Map (Load Mode)

advertisement
Models:
TS-45 (Load Mode)
TS-60 (Load Mode)
Load & Lighting Control
Battery Voltage / Temp. / Current
Ah resettable / Load State
Operating
Displays
13.5V 25C 12.3A
1234.5Ah NORMAL
Reset Ah
(Hold  2 sec)
Manual
Operations
Battery Voltage Graph
Load Current Graph
Battery Max. / Ah Total Counter Battery Voltage / Temp. / Watts
Battery Min. / kWh Total Counter
kWh resettable / Load State
V
A
14.4V 11357AhT
12.3V 11.3kWhT
Clear Resettable Ah / kWh Counters
Clear Battery Max. / Min. Voltages
13.5V 25C 12.3A
367W NORMAL
( to Return)
Diagnostics
Faults:  1 o f 1 
Turn Load OFF
(Hold  2 sec)
Diagnostics
HVD
Turn Load On / Off
TriStar Hardware / Software Ver.
Controller Serial Number
Diagnostics
(Press  )
Meter Hardware / Software Ver.
TriStar
Settings
TriStar Settings
(Press  )
TriStar Mode of Operation
System Voltage
Battery Type (see manual)
Float Charge Voltage
View Logged
Data*
Logged Data
(Press  )
Low Voltage Disconnect Value
Low Voltage Reconnect Value
Meter Display Language
(Hold 3 seconds)
Modify
Settings**
13.5V 25C 367W
123 kWh NORMAL
Battery Voltage / Temp. / Current
Battery Watts / Load State
Advanced Setup
(Press  )
Meter Display
Temperature Units
* Logged data feature supported in
TriStar firmware versions v13 and later.
** Modify Settings feature supported in
TriStar firmware versions v15 and later.
Adjust the
MeterBus Address
( to Return)
Advanced Setup
Meter addr
2

TriStar and TSM-2 firmware updates are
available on our website:
www.morningstarcorp.com/en/support
( to Return)
TriStar Settings
TS-60 v01.01.01
Serial: 09250001
Meter v01.01.01
Mode:
12V (Auto)
Battery #: 4
Load
LVD:
LVR:
11.5V
12.6V
Language
English
Units:
°C 

( to Return)
Logged Data
To d a y : B a t t e r y
51.2 Vmax
To d a y : B a t t e r y
45.5 Vmin
To d a y :
Load
1234.5 Ah
To d a y :
Faults
NONE
To d a y :
Alarms
NONE
Today’s Data
Alarms:
NONE
Battery
14.35V 12.44A
Battery Sense
14.40V valid
State: NORMAL
Load: 17.70V
total: 23547Ah
Reset: 1234.5Ah
TriStar: 35°C
123456 hours
Reset Ah Total
(Hold  2 sec)
Faults List
Alarms List
Battery Voltage / Load Current
Battery Sense Voltage
Load State
Load Output Voltage
Total Ah Counter
Resettable Ah Counter
TriStar Heatsink Temperature
Cumulative Hours of Service
Clear Total Ah / kWh Counters
Day: -01 Battery
51.2 Vmax
Day: -01 Battery
45.5 Vmin
Day: -01
Load
1234.5 Ah
Day : -01 Faults
NONE
Day: -01 Alarms
NONE
Day:-XXX Battery
51.2 Vmax
Day:-XXX Battery
45.5 Vmin
Day:-XXX
Load
1234.5 Ah
Day :-XXX Faults
NONE
Day:-XXX Alarms
NONE
Yesterday’s Data
Data X Days Ago
Alarms
Description
Faults
Description
Ths Disconnected
heatsink temp. sensor is open
External Short
external short circuit
Ths shorted
heatsink temp. sensor shorted
Overcurrent
current exceeds rating
TriStar HOT
limiting current due to high temp.
FET Short
power switches may be damaged
Current limit
limiting an overcurrent condition
Software
software problem
Current offset
current measurement off > 1 Amp
HVD
high voltage disconnect
Battery sense
battery voltage sense error
TriStar HOT
heatsink temperature exceeded limits
Batt Sense disc
battery sense no longer connected
DIP sw changed
Uncalibrated
controller not factory calibrated
a settings switch was adjusted while
running
miswire
system wiring problem detected
Setting Edit
new setting(s) written to custom
settings memory
FET open
power switches not turning on
Reset?
a reset due to an interrupted fault
P12
internal power supply problem
Miswire
system wiring fault
8 Pheasant Run
Newtown, PA 18940 USA
info@morningstarcorp.com
www.morningstarcorp.com
MS-ZMAN-TSM2-03-C