® NPX-24 NPX-24FR Sealed Rechargable Lead-Acid Battery 12V, 24W/Cell-15 min SPECIFICATIONS • NOMINAL CAPACITY: 20 hr. rate of .3A to 10.5V 10 hr rate of .56A to 10.5V 5 hr rate of 1.02A to 10.2V 1 hr rate of 3.6A to 9.3V • WEIGHT (approx.): 5.02 pounds (2.28kgs.) 24 34 53 6.0Ah 5.6Ah 5.1Ah 3.6Ah • INTERNAL RESISTANCE OF CHARGED BATTERY: 17 milliohms (approx.) • MAXIMUM DISCHARGE CURRENT WITH STANDARD TERMINALS: 60 amperes • MAXIMUM SHORT-DURATION DISCHARGE CURRENT: 180 amperes • OPERATING TEMPERATURE RANGE: CHARGE 5°F to 122°F (-15°C to 50°C) DISCHARGE -4°F to 140°F (-20°C to 60°C) • CHARGE RETENTION (shelf life) at 68°F (20°C): 1 month 97% 3 months 91% 6 months 85% • LIFE EXPECTANCY: STANDBY USE CYCLE USE (approx.): 100% depth of discharge 50% depth of discharge 30% depth of discharge 0.313 0.250 0.180 0.098 0.059 0.031 0.020 0.004 Positive 250 cycles 550 cycles 1200 cycles • SEALED CONSTRUCTION: Can be operated in any position except permanent inversion without leakage • STANDARD TERMINAL: Positive .250 mm Negative .187 mm 7.95 6.35 4.57 2.49 1.50 0.79 0.51 0.10 INCH = MM 3 to 5 years 0.250 0.187 0.124 0.098 0.059 0.031 0.020 0.004 Negative Dimensions • HOUSING MATERIAL: ABS Resin 100 (3.94) ± 2 94 (37.2) ± 2 • NOMINAL WATTAGE/CELL: 15 min. discharge rate to 1.67V/cell 10 min. discharge rate to 1.67V/cell 5 min. discharge rate to 1.67V/cell INCH = MM • OPTIONAL: Container and cover made from Flame Retardant ABS (UL94-V0/L.O.I.>28%) • Approved for shipping as non-hazardous, non-spillable 151 (5.95) ± 2 51 (2.01) ± 2 • NOMINAL VOLTAGE: 12V Terminals www.enersys-emea.com Publication No: EN-NPX24-FL-001 March 2009 © 2009 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates, except ISO 9000TM, which is not the property of EnerSys. Subject to revisions without prior notice. E.&O.E. 6.35 4.75 3.15 2.49 1.50 0.79 0.51 0.10