EDWG11HWLC4401 WIRING DIAGRAM FOR 1-PHASE OPERATOR- MODEL : OPH/OPJ/OSH/OTH/OTBH/OSL/OBH/OSJ CLOSE CAM OPEN CAM YELLOW ORANGE ORANGE NC BLUE NO ADV. OPEN LIMIT SWITCH. OPEN LIMIT SWITCH. COM BROWN BROWN COM NC NO NC NO ORANGE ADV. CLOSE LIMIT SWITCH. CLOSE LIMIT SWITCH. NC NO COM BROWN COM GRAY ORANGE RED/BK BLACK RED RED BLUE RED RED BRAKE SOLENOID (IF USED) BLACK RED R YELLOW 5 6 3 4 1 2 MANARAS 1 RADIO 2 RECEIVER 3 5 6 RED RED/BK RED RED/BK 4 1 2 REVERSING RELAY WHITE 3 OSH 14 PURPLE BLUE A2 CLOSE COIL 13 RED/BK RED ORANGE BLACK MOTOR 1-PHASE 220 VAC 60 HZ BLACK RED BLUE A1 TIME DELAY 1.5 SEC (WHEN REQ'D) BLACK RED T1 YL OR BLUE RED BLACK RED/BK BRAKE SOLENOID (IF USED) T2 T3 WH BK T5 9 BLUE OR T8 R 8 DISCONNECT SWITCH MOTOR 1-PHASE 120 VAC 60 HZ BK 7 ORANGE T2 BL T4 T4 GRAY 14 BROWN T5 A2 13 BLACK T1 YL T3 WH T8 OPEN COIL A1 GRAY BROWN WHITE BLACK BROWN BL BLACK BLUE YELLOW BLACK CIRCUIT BREAKER B2 BLUE GRAY BLUE BLACK RED LOAD LINE RED BROWN WHITE BROWN BLACK BLACK WHITE BLACK MOTOR RELAY TRANSFORMER VAC PRIMARY 24 VAC SECONDARY 40 VA C2 WHITE GRAY GRAY PURPLE PURPLE YELLOW 9 DISCONNECT SWITCH 8 N.O 7 6 N.C 5 YELLOW 4 YELLOW 3 OPJ 2 N.O STOP COM OPEN CLOSE SAFETY COM OPEN/ 24 VAC DEVICE CLOSE PUSH-BUTTONS N.C 1 YELLOW 24 VAC POWER COM REMOVE TO INSTALL INTERLOCK OPH GROUND LUG BLUE AND ORANGE WIRES ON REVERSING CONTACTOR. HOIST SWITCH N.C *1. TRANSFORMER AND MOTOR RELAY ARE SAME AS THE LINE VOLTAGE *2. BLACK JUMPER BETWEEN C-2 AND C-4 IS NOT REQUIRED FOR 220 VAC MOTORS. *3. TO REVERSE MOTOR ROTATION INTERCHANGE N.O OTBH/OTH NOTE- HOIST SWITCH IS NOT AVAILABLE ON TROLLEY OPERATORS. WHITE BLACK BROWN BROWN BLUE BLUE RED PURPLE PURPLE RED/BK RED RED ORANGE PURPLE GRAY YELLOW GRAY PURPLE NOTE:- 115 / 208 / 220 VAC 1 PHASE 60 Hz L/L1 N/L2 PURPLE PURPLE 2 AMP FUSE EXTERNAL WIRING 1 2 3 6 7 8 5 4 4 3 2 5 3 4 3 RADIO RECEIVER 2 7 CLOSE COM COM CONTACT FOR OPEN/ CLOSE DOOR DEVICE. KEY-SWITCH 1A 1B NOTE- C2 / B2 REMOVE THE RED WIRE WITH RAPID C2 CONNECTOR FROM TERMINAL #7, AND TRANSFER IT TO TERMINAL #5. WARNING: MOTORISED DOORS CAN CAUSE SERIOUS INJURIES OR DEATH. MANARAS STRONGLY RECOMMENDS THE USE OF ENTRAPMENT PROTECTION SYSTEMS, ESPECIALLY IN THE CASES OF MOMENTARY CONTACT TO CLOSE AS IN B2 WIRING OR TIMER TO CLOSE. 2 DATE: CAD FILE: 20.SEPT.2010 EDWG11HWLC4401 MANARAS-OPERA 136 ONEIDA DRIVE POINTE-CLAIRE, QC H9R 1A8 TEL: 1-800-361-2260 FAX: 1-888-626-0606 CONSTANT PRESSURE OPEN STOP ADDING A TIME DELAY ON REVERSE 4 ADV. OPEN L.S. ORANGE 1. REMOVE THE YELLOW WIRE FROM ADV. OPEN LIMIT SWITCH, CONNECT THIS WIRE TO ONE END OF TIME-DELAY. ORANGE YELLOW BLUE 2. FROM OTHER END OF THE TIMEDELAY, CONNECT BACK TO ADV. OPEN LIMIT SWITCH. 1.5 SEC. YELLOW 3 WIRING DIAGRAM- 120/208/240 VAC 1-PHASE BP STOP PLACE A JUMPER BETWEEN TERMINAL #2 AND #3, IF STOP BUTTON IS NOT USED. 1. REMOVE THE GRAY WIRE FROM TERMINAL #3 AND PLACE IT ON TERMINAL # 4 B2 TITLE: DRAWN BY: OPEN CLOSE ON SITE MODIFICATIONS REMOVE THE RED WIRE WITH RAPID B2 CONNECTOR FROM TERMINAL #5, AND TRANSFER IT TO TERMINAL #7. C2 OPEN CLOSE STOP ATTENTION- USE 18AWG OR HIGHER FOR WIRING ALL EXTERNAL CONNECTIONS. 1 CLOSE 9 RC CONTACT FOR SAFETY DEVICE OPEN 1 REMOVE TO INSTALL INTERLOCK POWER 24 VAC POWER AVAILABLE 10VA MAX. PURPLE OPEN POWER SUPPLY 115/208/220 VAC 1 Ph, 60 Hz. 8 BROWN 5 9 TWO PUSH-BUTTON STATION BLUE SINGLE PUSH-BUTTON STATION 3 1 3-POSITION KEY SW. W/SPRING RETURN TO CENTRE 2 L/L1 N/L2 OPEN/CLOSE COMMAND GROUND LINE POWER SAFETY REVERSE CONTACT EXTERNAL INTERLOCK POWER 24 VAC REV DATE: L 02.NOV.2012 WIRING FOR INSTANT STOP (ON SAFETY EDGE OR DEVICE) 1. REMOVE THE YELLOW WIRE FROM ADV. OPEN LIMIT SWITCH, AND CAP IT. 2. REMOVE THE BLUE WIRE FROM PIN # 4 OF REVERSING RELAY(RR) AND CAP IT. T.D. MODULE CONSTANT PRESSURE OPEN AND CLOSE - D1 5 PERFORM THE MODIFICATION EXPLAINED IN THE NOTES, 1B 2 AND 3 6 ANY OTHER OPTIONS FOR ANY OTHER OPTIONS LIKE, TIMER TO CLOSE,MID-STOP WIRING, LONG DISTANCE MODULE OR ANY OTHER SPECIAL LOGIC SEQUENCE PLEASE CONSULT MANARAS/ OPERA. THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO MANARAS-OPERA, AND SHALL NOT BE REPRODUCED OR DISCLOSED OR USED FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN USER POSSESSES DIRECT WRITTEN AUTHORIZATION FROM MANARAS-OPERA.