Pure Lead and Sealed Lead Acid Batteries

advertisement
Pure Lead and Sealed Lead Acid Batteries
B
C
N
NSP
O
ILLA
IL
P
BLE
LA
B
b
LE
Pb
S
N
NO
P
A
PURE LEAD RECHARGEABLE BATTERIES
• High-Rate Power Density
• Capable of more than 300 Cycles
• High Stable Voltage Delivery
• Wide Temperature Range:
•
•
•
• Fast Recharge: up to 95% Recharge in Less Than One Hour
• Maintains Performance and Physical Parameters in Extreme Conditions
• Can be mounted and operated in any position
Cyclon Single Cells: -65°C ~ +80°C
Monobloc: -40°C ~ +40°C
Provides the Longest Service Life Possible
Low Self-Discharge Rate
Rugged Construction
Cyclon 2 Volt Single Cells
MOUSER
STOCK NO.
846-0810-0004
846-0800-0004
For quantities greater than listed, call for quote.
Enersys
Part No.
Price Each
Dimensions: in.
Fig.
Size
Capacity
(Ah)
A
A
D
X
2.5
5.0
Fig.
Size
Capacity
(Ah)
Diameter
Height
Height Over Term.
Weight (lbs.)
Tabs
1
0819-0010
0809-0010
0859-0010
B
B
B
D
X
E
2.5
5.0
8.0
3.13
3.80
3.81
1.81
2.12
2.13
2.75
3.02
4.00
0.8
1.62
2.11
0.187 x .025
0.250 x .025
0.250 x .025
0819-0012
0809-0012
0859-0012
C
C
C
D
X
E
2.5
5.0
8.0
4.48
5.48
5.48
1.81
2.12
2.13
2.75
3.02
4.00
1.15
2.16
3.15
0.187 x .025
0.250 x .025
0.250 x .025
0810-0004
0800-0004
Diameter
1.35
1.75
Height
2.41
2.87
Height Over Term.
2.68
3.21
Weight (lbs.)
0.39
0.80
Tabs
.187 x 0.25
.250 x .025
Cyclon 4 and 6 Volt Monoblocs
MOUSER
STOCK NO.
4 Volt
846-0819-0010
846-0809-0010
846-0859-0010
6 Volt
846-0819-0012
846-0809-0012
846-0859-0012
1
10.84
16.28
5
9.94
14.97
10
9.40
14.08
25
8.99
13.64
For quantities greater than listed, call for quote.
Enersys
Part No.
Dimensions: in.
Price Each
5
10
25
23.55
36.76
33.97
22.02
33.79
31.18
20.72
31.79
28.77
19.43
29.81
28.40
26.73
35.13
41.73
24.57
34.18
38.24
23.12
32.29
36.05
21.68
30.38
33.65
SEALED LEAD-ACID BATTERIES
• High Quality and Reliability
• Exceptional Deep Discharge Recover
• No Corrosive Gas Generation
• Long Service Life
• Quick Chargeability
• High Power Density
• Maintenance-Free Operation
For quantities greater than listed, call for quote.
MOUSER
STOCK NO.
658-LCR061R3P
658-LC-R063R4P
658-LCR064R5P
658-LCR067R2P
658-LCR067R2P1
658-LCR0612P
658-LCR0612P1
658-LC-R121R3P
658-LC-R122R2P
658-LC-R123R4P
658-LCR127R2P
658-LCR127R2P1
658-LCRD1217P
658-LCLA1233P
Panasonic
Part No.
LC-R061R3P
LC-R063R4P
LC-R064R5P
LC-R067R2P
LC-R067R2P1
LC-R0612P
LC-R0612P1
LC-R121R3P
LC-R122R2P
LC-R123R4P
LC-R127R2P
LC-R127R2P1
LC-RD1217P
LC-LA1233P
Nominal
Voltage
6
6
6
6
6
6
6
12
12
12
12
12
12
12
Capacity
20 Hr. Rate
(Ah)
1.3
3.4
4.5
7.2
7.2
12.0
12.0
1.3
2.2
3.4
7.2
7.2
17.0
33.0
Dimensions: in.
Terminal
Type
L
W
H
.187" Faston
.187" Faston
.187" Faston
.187" Faston
.250" Faston
.187" Faston
.250" Faston
.187" Faston
.187" Faston
.187" Faston
.187" Faston
.250" Faston
Nut and Bolt
Nut and Bolt
3.82
5.28
2.76
5.95
5.95
5.95
5.95
3.82
6.97
5.28
5.95
5.95
7.13
7.70
0.95
1.34
1.89
1.34
1.34
1.97
1.97
1.87
1.34
2.64
2.54
2.54
2.99
5.12
1.97
2.36
4.02
3.70
3.70
3.70
3.70
1.97
2.36
2.36
3.70
3.70
6.57
6.10
Weight (lbs.)
0.66
1.37
1.59
2.78
2.78
4.30
4.30
1.30
1.76
2.65
5.45
5.45
14.34
26.50
Cycle Use
Initial
Current
0.52A
1.36A
1.80A
2.88A
2.88A
4.8A
4.8A
4.8A
0.88A
1.36A
2.88A
2.88A
6.8A
13.2A
Control Volt.
7.25-7.45V
14.5-14.9V
7.25-7.45V
7.25-7.45V
7.25-7.45V
7.25-7.45V
7.25-7.45V
7.25-7.45V
14.5-14.9V
14.5-14.9V
14.5-14.9V
14.5-14.9V
14.5-14.9V
14.5-14.9V
Trickle Use
Initial
Current
0.195A
0.51A
.675A
1.08A
1.08A
1.8A
1.8A
1.8A
0.33A
0.51A
1.08A
1.08A
2.55A
4.95A
Control Volt.
Price
Each
6.8-6.9V
13.6-13.8V
6.8-6.9V
6.8-6.9V
6.8-6.9V
6.8-6.9V
6.8-6.9V
6.8-6.9V
13.6-13.8V
13.6-13.8V
13.6-13.8V
13.6-13.8V
13.6-13.8V
13.6-13.8V
18.26
26.75
15.84
26.06
26.06
36.09
45.46
28.28
33.13
39.49
39.26
39.26
85.32
175.93
BATTERY CAPACITY ANALYZER
Applications:
Specifications:
• Measures both No Load
Voltage and Battery Capacity
• Displays storage capacity of 12V
lead acid batteries as a percentage
Rechargeable
The need for battery maintenance tools is growing for use in Automotive, Field Service and Maintenance, Telecommunications, and
UPS Manufacturing/Maintenance applications. Perfect instrument for anyone working with UPS systems, Emergency back-up Flood
Lights, Home and Business Security Alarm Systems, or for any applications using a 12 volt lead acid battery.
• Powered by battery under test
For quantities greater than listed, call for quote.
MOUSER
STOCK NO.
615-600
615-601
B&K
Part No.
600
601
© Copyright 2012 Mouser Electronics
Max
Input Volt
20V
20V
Dimensions: in.
W
3.14
3.14
mouser.com
H
6.30
9.50
D
1.60
1.60
Weight
(lbs)
Cap. Display
Range
Price
Each
2.20
2.30
0-100%
0-100%
329.00
439.00
(800) 346-6873
© Copyright 2012 Mouser Electronics
2233
Download