Microbiological Safety Cabinet TOP SAFE CLASSE II Microbiological Safety Cabinet Continuous monitoring of Safety parameters Alarms for low air flow and wrong front window position Sloped front and back wall for the most comfortable access Front access for filter maintenance and service Easy retrofittable option kits Top Safe Cabinets are supplied in three different sizes (1.2mt, 1.5mt and 1.8mt). These last generation Microbiological Safety Cabinets have been certified according to the most stringent safety standards (EN12469-2000). The internal design, the air flow aerodynamics and monitoring, the built-in safety devices and the very accurate manufacturing, guarantees the highest performances at the most stringent safety levels, as specified by EN12469 standard and have been tested by the most prestigious European certification bodies for Safety Cabinets. Main specifications • Microprocessor controlled motor blower, with volumetric sensor for exhausted air flow monitoring • Highest air flow stability both in case of transitional disturbances or to progressive filter clogging • Continuous monitoring of front barrier air flow for the highest operator safety • Low barrier alarm • Free voltage contact for remote monitoring of exhaust fan. • Bar-graph analogical display for the easiest reading of air speed value (barrier and down flow air speed display for regular, pre-alarm and alarm conditions) Mechanical and functional specifications • Sloped front design for the highest operational comfort. Sloped back side of the working chamber for the best down flow distribution • Utilities inlets from the top of the cabinet. S-SAFEHOODENGL-R0-0704 • • • • • • • • • • • • • • • • • • • • • • • Stainless Steel internal surfaces with 2B finishing (including spillage tray). Solid work surface (3 sections) and special designed front grill. Hinged multilayer safety glass window (max opening at 120°) Comfortable 200mm front opening Front closing panel Retrofittable options through lateral sides. Exposed exhaust Hepa filter for easy visual integrity chck. Filter change and maintenance from the front of the cabinet. Exhaust transitions easily installable. Key operated. The key can be removed when the unit is in SAFE mode, in order to avoid unwanted operation. In case of power failure, the cabinet is re-set to original working conditions. Self check cycle performed when cabinet is switched on. High speed rinse and set up cycle performed, before reaching the SAFE operating mode. Visual display of SAFE conditions. Pre-warning before actual alarm conditions are reached (visual and acoustic alarms) Soft touch control with keys for standard service utilities. Interconnected UV and fluorescent lights. H14 class High Efficiency Particulate Air filters with 99.999% efficiency on .3micron particles Exhaust and recirculating flow rates ensure 25 air changes/min in the working area (30% 70% split) Front barrier air speed ≥ 0.5mt/sec Aperture protection Factor (Apf) ≥ 1.5 x 10 exp 5 Cleanability Index CC grade, according to EN12469 standard Light intensity on work surface ≥ 800 lux. Noise level, complies with EN 12469:2000, determined according to EN ISO 3744 and ISO 11201 230V, 50Hz Max power (for each power point) 3Amps. Microprocessor equipped with analogical watch dog. CE certification according to Machinery Directive 89/392/EEC, 91/368/EEC, 93/44/EEC 93/68/EEC. TECHNICAL CHARACTERISTICS TOPSAFE Model TOPSAFE Class II External Dimension (LxWxH) mm Weight (Kg) Internal Dimension camera di lavoro (LxPxA) mm Power (excl. int. power point) (KW) Power point Fluorescent Light Fans Work Surface Sections OPTIONALS Standard Options (incuded) Elapsed time meter Service power point Solenoid valve for gas Gas and vaacum taps UV light kit (optional) connections S-SAFEHOODENGL-R0-0704 1.2 1.5 1.8 1380x795x1450 180 1230x580x710 1685x795x1450 220 1530x580x710 1990x795x1450 290 1840x580x710 0,7 1 2x30W 1 3 1 1 2x36W 1 3 1,4 2 2x58W 2 4 Standard Options (not included) Prefilter grid Retrofittable kits for gaseous fluids Pass-through holes for additional utilities Second gas line kit with solenoid valve UV light kit with or without timer Passive exhaust transition for formaldheyde fumes eshaust or, alternatively, activated charcoal filter with relevant accessories Formaline vaporiser Active exhaust transition (with fan) for ducted configuration Remote active exhaust transition (with fan) for exhaust through negative presure duct (to be used with Passive exh. Transition) Thimble Notes: ehaust transitions can be delivered according to specific customer requirements. S-SAFEHOODENGL-R0-0704 s@feflow family Microbiological Safety Cabinet Class II , Type A ,B3 convertible Designed to provide protection to the operator,the product and the environment,against risks due to airborne contamination THE ULTIMATE SAFETY CABINET S@feflow is Microbiological Safety Cabinet (MSC) Class II, type A,B3 convertible, designed to provide protection to the oprator, the product and the environment, against risks due to airbome contamination. Ventilation of the cabinet includes recirculating air flow, filtered through high efficiency filter (HEPA) and a make-up air, passing through the front opening and then discharged through an exhaust HEPA filter into the environment. Recirculated and make-up air flows are maintained at a pre-set value by a closed loop microprocressor, which automatically monitors and controls the air volumes, assisted by an advanced volumetric sensor. S@feflow is a MSC certified according to EN 12469. S@feflow has a sloped front, ergonomically designed to maximise the cabinet's operating comfort and user friendliness. An electrically operated sliding sash can be moved up and down at different opening heights : at a finger tip touch, an electronic device automatically searches for the optimised height of the front opening. Operating mode: •Type A configuration:The air leaving the main HEPA filter at a constant speed produces a laminar downflow Class 100 enviroment.An air barrier enters through the front opening at a speed of 0.45 m/s and is mixed with the downflow air underneath the work surce.70% of the air is recirculated 30% is ducted through the port on top of the unit. Type B3 configuration: The operating principle is the same but the unit is ducted to the outsite of the laboratory . Moreover the sash is hinged at the top, allowing easy cleaning of the internal surface of the glass.The microprocessor has a large, high resolution display , and all functions available both for operator and service staff, and are easily set through multi-task switches. Main functions includes: •display of speed/volume values of air (downflow and front barrier) •alarms: airflow and windows •introduction of two different passwords to enter operational or service mode •automatic fumigation cycle (with automatic set up of front sliding sash at defined heights in the different phases of the fumigation cycle). •UV cycles control •Filters life •UV lamp life S-SAFEFLOWFAMILY-R0-0704 Page 1 of 2 BIOAIR Instruments s.r.l. is part of group of company TECHNICAL DATA S@FEFLOW FAMILY S@feflow 0.9 Work chamber dimensions (lxdxh): 879x480x650 mm Overall dimensions (lxdxh): 1055x792x1455 mm Weight: 200 kg Power supply: 230V-50Hz Power requirement: 1.750 W Noise Level ≤57dB (A) Lighting ≥800 lux S@feflow 1.2 1183x480x650 mm 1360x792x1455 mm 270 Kg 230V-50Hz 1.780 W ≤57 dB (A) ≥800 lux S@feflow 1.8 1793x480x650 mm 1970x792x1455 mm 350 Kg 230 V 50 Hz 2.370 W ≤57 dB (A) ≥800 lux HOW TO ORDER Code LD LD LD LD LD LD LD 80000 60000 70000 80001 60001 70001 60200 Item S@feflow 0.9 with perforated working surface EN 12469 version S@feflow 1.2 with perforated working surface EN 12469 version S@feflow 1.8 with perforated working surface EN 12469 version S@feflow 0.9 with solid working surface EN 12469 version S@feflow 1.2 with solid working surface EN 12469 version S@feflow 1.8 with solid working surface EN 12469 version S@feflow 1.2 BS with perforated working surface and with dual exhaust HEPA filter ACCESSORIES FOR S@feflow 0.9, 1.2 and 1.8 Code AK AS AK AS AS AZ 17000 18000 16000 16000 17000 33000 Item UV-Lamp for S@feflow 0.9 Support stand for S@feflow 0.9 UV-Lamp for S@feflow 1.2 (EN 12469 and BS version) and S@feflow 1.8 Support stand for S@feflow 1.2 (EN 12469 and BS version) Support stand for S@feflow 1.8 Formaldehyde vapourizer for all S@feflow models Other accessories for S@feflow 1.2 AZ 16100 Transition adapter with extraction fan (without filter) according to customer's specifications AZ 16300 Passive transition adapter AZ 16400 Extraction open hood (thimble without fan) AZ 16400 Extraction charcoal filter (with charcoal filter) only for S@feflow 1.2 EN 12469 Version (not for BS version) S-SAFEFLOWFAMILY-R0-0704 Page 2 of 2 BIOAIR Instruments s.r.l. is part of group of company AURA 2000 M.A.C family Microprocessor Automatic Control Microbiological Safety Cabinet with microprocessor based control Personnel protection, product protection and ambient safety from exposure to biological agents Class II microbiological safety cabinet for handling of low - moderate risk-hazarded agents; certified LNE (AFNOR) EN 12469-2000 BIOHAZARD The AURA 2000 M.A.C. is a Class II Microbiological Safety Cabonet 70% of fhe HEPA filtered air is therefore reciculated with the remaining 30% being expelled through a dedicated exhaust HEPA filter. The cabinet is used to reduce the exposure.The AURA 2000 M.A.C has a new, electronic airflow control system.A microprocessor based module provides automatic control of the airflow throughout the whole life of the HEPA filter. The microprocessor based module contains the alarm system which warns the operator when recirculated and exhaust airflow rate deviate from the fixed operation range and when the front windows is not firmly closed.The soft-touch keyboard together with the alphanimeric display, bargraphs and pilot lamps give the operators a full controll control and monitoring of all functions.Laminare flow and face velocites are permanently displayed while the UV lamp,cabinet conditions ,filters, run hours and blackout events are displayed by touching the multifunction keys. The microprocessor module also controls the lights ,electrical power outlet, gas solenoid valve and 24 hours clok with UV time function. All of the contaminated plenum inside the cabinet is surrounded by a negative pressure to prevent contaminated air leaks,as required by the latest international standard •The microprocessor control module is located inside the front panel in a non contaminated zone •The air flow control system provides a constant air flow unit the pressure across the HEPA filter emissing in reaches a level that the fan cannot compensate •The digital display and air velocity bargraph indicators give a continuous monitoring of the air flow conditions. •Visible and audible alarms are actived when the laminar and exhaust air flow rates fall or exceed the fixed thresholds and when the fro is not closed securely. •Sof touch keys on the control panel provide control of the lighiting,UV lamp,electrical power outlet and the solenoid valve which regulat supply line. •Variable speed centrifugal fan with built-in thermal cut-out •Electrical equipment accoding to EN 61010-1 International Standards and EMC directives. •Ligting >800 lux. •Noise level complies with EN 12469:2000, determined according to EN ISO 3744 and ISO 11201 •Cabinet outer surfaces of rolled steel with paint finish. •Inner chamber made of AISI 304 stainless stell with radiussed cormers and full access to exposed surfaces for ease of cleaning. •Removable work surface made of AISI 304 stainless steel with perforated work area and shaped front grille to prevent obstruction of the safety air barrier intake. S-AURA200MACFAMILY-R0-0704 Page 1 of 2 BIOAIR Instruments s.r.l. is part of group of company •Sump made of AISI 304 stainless steel,with coved comers for easy remaval of spilt liquids. TECNICAL DATA AURA 2000 MAC FAMILY Work chamber dimensions (LxDxH): Overall dimensions (LxDxH): Weight: Power supply: Power requirement: Lighting Noise AURA 2000 M.A.C.3 AURA 2000 M.A.C.4 AURA 2000 M.A.C.6 880x580x670 mm 1.185x580x670 mm 1.795x580x670 mm 1.145x785x1.460 mm 1.450x785x1.460 mm 2.060x785x1.460 mm 175 kg 225 kg 310 kg 230 V 50 Hz 230 V 50 H 230 V 50 Hz 1.750 W 2.200 W 2.370 W 800 LUX 800 LUX 800 LUX Level noise level comply with EN 12469:2000, determined according to EN ISO 3744 and ISO 11201 HOW TO ORDER Code LD00100 LD50300 LD90100 Item AURA 2000 M.A.C. 3 AURA 2000 M.A.C 4 LNE (AFNOR) EN 12469-2000 approved AURA 2000 M.A.C 6 Accessories for Aura 2000 M.A.C. 3/4/6: Code Item AS14000 AK17000 AS15000 AK15000 AS19000 AC10000 Support stand for AURA 2000 M.A.C UV lamp for AURA 2000 M.A.C 3 Support stand for AURA 2000 M.A.C.4 UV lamp for AURA 2000 M.A.C.6 Drawer for all AURA 2000 M.A.C models Support stand for AURA 2000 MAC 6 Other accessories for Aura 2000 MAC 4: Code AZ15100 AZ15300 AZ15200 Item Exhaust kit with motorblower for AURA 2000 MAC 4( filter excluded) Exhaust Adapter for AURA 2000 MAC Exhaust passive adapter for AURA 2000 MAC An additional (HEPA or charcoal) filter can be installed with item AZ15100 S-AURA200MACFAMILY-R0-0704 Page 2 of 2 BIOAIR Instruments s.r.l. is part of group of company AURA 2000 M.A.C BS Microbiological Safety Cabinet with microprocessor based control and dual exhaust hepa filter Personnel protection, product protection and ambient safety from exposure to biological agents Class II microbiological safety cabinet for handling low to moderate risk-hazarded agents; certified BS 5726 dual exhaust HEPA. CERTIFIED BS 5726 BIOHAZARD The AURA 2000 BS is a Class II Microbiological Safety Cabinet. 70% of the HEPA filtered air is therefore recirculated with the remaining 30% being expelled through two online dedicated exhaust HEPA filters. The cabinet is used to reduce the exposure of both product and personnel to airborne biological agents. The AURA 2000 B.S. has a new, electronic airflow control system. A microprocessor based module provides automatic control of the airflow throughout the whole usable life of the HEPA filters. The microprocessor based module contains the alarm system which warns the operator when recirculated and exhaust airflow rate deviate from the fixed operation range and when the front window is not firmly closed. The softtouch keyboard together with the alphanumeric display, bargraphs and pilot lamps give the operators full control and monitoring of all functions. Laminar flow and face velocities are permanently displayed while the UV lamp, cabinet conditions, filters, run hours and blackout events are displayed by touching the multifunction keys. The microprocessor module also controls the lights, electrical power outlet, gas solenoid valve and 24 hour clock with UV timer function. All of the contaminated plenum inside the cabinet is surrounded by a negative pressure to prevent contaminated air leaks as required by the latest international standard.All of the contaminated plenum inside the cabinet is surrounded by a negative pressure to prevent contaminated air leaks,as required by the latest international standard •Variable speed centrifugal fan with built-in thermal cut-out. •Electrical equipment according to IEC 1010-1 International Standards and EMC directives. •Lighting > 800 lux. •Noise level < 62 dB (A) •Cabinet outer surfaces made of rolled steel with paint finish. •Inner chamber made of AISI 304 stainless steel with radiussed corners and full access to exposed surfaces for ease of cleaning. •Removable work surface made of AISI 304 stainless steel with perforated work area and shaped front grille to prevent obstruction of the safety air barrier intake. •Sump made of AISI 304 stainless steel, with covred corners for easy removal of spilt liquids. •The microprocessor control module is located inside the front panel in a non contaminated zone. •The air flow control system provides a constant air flow until the pressure across the HEPA filter in reaches a level that the fan cannot compensate •The digital display and air velocity bargraph indicators give a continuous monitoring of the air flow conditions •Visibile and audible alarms are activated when the laminar and exhaust air flow rates fall or exceed the fixed thresholds and when the front window is not losed securely. •Soft touch keys on the control panel provide control of the lighting, UV lamp, electrical power outlet and the solenoid valve which regulates the gas supply line. •Two on line exhaust HEPA filters. •Two dedicated D.O.P. ports. S-AURA200BS-R0-0704 Page 1 of 2 BIOAIR Instruments s.r.l. is part of group of company TECHNICAL DATA AURA 2000 MAC BS Work chamber dimensions (LxDxH): Overall dimensions (LxDxH): Weight: Power supply: Power requirement: Noise Level Lighting 1185 x 580 x 670 mm 1450 x 785 x 1440 mm 225 kg 230 V 50 Hz 2.200 W ≤62 dB (A) ≥800 LUX HOW TO ORDER Code LD50200 AK15000 AS15000 AC10000 Item Microbiological Safety Cabinet (Class II) UV lamp for Aura 2000 Support stand for Aura 2000 Drawer for model AURA 2000 S-AURA200BS-R0-0704 BS BS BS BS Page 2 of 2 BIOAIR Instruments s.r.l. is part of group of company AURA VF Laminar downflow workstation Probably the highest Apf (Aperture protection factor) in its category for the safest handling of products The aura VF has been designed and tested for the following applications: Manipulation of non pathogenic micro-organisms Animal and plant Cell-cultures Molecular biology Drug preparation Assembly of optical and electronic components Food Industry LAMINAR DOWNFLOW CLASS 100 Maximum operator, product and environmental protection on the Aura VF is obtained with a design identical to the one typical of biosafety cabinets. The unit works on a recirculatory principle with air passing through the main HEPA filter before entering the work area where Class 100 conditions are obtained. Air coming through the front aperture is then mixed with the downflow air without affecting the product, and recirculated; 30% of it is exhausted into the environment through an exhaust HEPA filter. 70% of the air is continually recirculated through the main HEPA filter. This ensures an environment conforming with Federal standard 209E class 100 and British standard 5295 class B. At the same time the operator and the environment are protected from any possible contaminant present in the working area. •Construction: epoxy coated mild steel •Base tray: AISI 304 stainless steel; autoclavable •Glazing: tempered glass •Filters types: main and exhaust filters: HEPA (high efficiency particulate airfilter) with efficiency of 99,999% tested, and conform to EN 1822 •CE marked •Fan: centrifugal with thermal cut-out. •Control panel: soft-touch membrane, on/off switch, fan switch, elapsed time meter, light switch. •Lighting: > 800 lux, fluorescent lights •Noise level < 60dB(A) Aura VF product specifications •Laminar downflow at a constant airspeed of 0.40 m/s •Face velocity: 0.45 m/s •Recirculatory mode with 70% recirculated air through main HEPA filter and 30% exhausted air through high efficiency exhaust filter •Electronic control. •Double plenum with dynamic air-tightness •Standard Optionals (included): S-AURAVF-R0-0704 Page 1 of 3 BIOAIR Instruments s.r.l. is part of group of company front closing panel, internal 6A socket, vacuum tap •Available as single HEPA filter configuration (downflow main HEPA only), no exhaust HEPA filter. S-AURAVF-R0-0704 Page 2 of 3 BIOAIR Instruments s.r.l. is part of group of company TECHNICAL DATA AURA VF 48 Work chamber dimensions (LxDxH): Overall dimensions (LxDxH): Weight: Power supply: Power requirement: Noise level: Lighting: 1190 x 580x 675 mm 1350 x 850 x 1415 mm 170 kg 230V - 50Hz 1.700 W < 60 d B (A) > 700 lux HOW TO ORDER Code LV10000 Item AURA VF 48 con doppio filtro HEPA ACCESSORIES FOR AURA VF MODEL Code AK10000 AZ50000 AS31000 AC10000 Item UV lamp for AURA VF 4 Solenoid gas valve for AURA VF 48 Support stand for AURA VF 48 Drawer for AURA VF 48 S-AURAVF-R0-0704 Page 3 of 3 BIOAIR Instruments s.r.l. is part of group of company AURA HZ Horizontal laminar air flow cabinet class 100 for product protection. HZ cabinets are designed according to the most advanced electronic and aerodinamic technologies in order to ensure a Contamination Controlled Environment of the highest quality Main applications for AURA HZ are: • Media preparation • Plant and animal tissue culture • Pharmaceutical preparations • Assembling of optical or microelectronic components • Micromechanics LAMINAR AIRFLOW CABINET CLASS 100 HORIZONTAL Automatic air control: AURA HZ is a horizontal laminar air flow cabinet, Class 100, for product protection from external contamination and cross-contamination inside the working chamber. The air speed is, for the highest product safety, permanently controlled. An integral vane anemometer is installed in the unit as a standard option. Venturi-effect side walls: special tempered-glass side walls are installed inside the air flow, to prevent any leakage from the outside. Operating mode: the air flow, leaving the HEPA filter at a constant speed, produces an extremely clean - better than Class 100 - environment in the work area, preventing any contamination to enter from the ambient outside. High efficiency washable polyurethane prefilters remouve coarse particles before the air reaches the HEP A filter. •Electrical equipment according to International Standards and EMC directives •Lighting › 800 lux •Noise level ‹ 60dB(A) •Electronic control air speed •Centrifugal motorblower •Bargraph display for air speed value •Soft touch keys on the control panel provide control of the lighting, motorblower, UV light. •Visible and acoustic alarms are provided for air speed alarm and filter clogging. •Two sizes to satisfy all applications •Cabinet outer surfaces made of cold rolled steel with paint finish •Working surface made of grade 3 stainless steel •Side panels in tempered glass •HEPA filter manufactured in accordance with MIL-F51068 and BS-3928, with an efficiency higher than 99.999% on 0.3µ particles, DOP tested •Micromesh membrane on HEPA filter downstream surface for perfect airspeed distribution •CE marked S-AURAHZ-R0-0704 Page 1 of 2 BIOAIR Instruments s.r.l. is part of group of company Work chamber dimensions (LxDxH) Overall dimensions (LxDxH) Weight Power supply Power requirement Noise level: Lighting HZ 48 HZ 72 mm 1120x610x732 mm 1350x1063x1353 128 kg 230V - 50Hz 0,42 kW < 60 dB > 700 lux mm 1730x610x732 mm 1960x1063x1353 194 kg 230V - 50Hz 0,8 kw < 60 dB (A) >700 Lux HOW TO ORDER Codice Item LH20000 LH30000 AURA HZ 48 Stainless steel work surface AURA HZ 72 Stainless steel work surface ACCESSORIES FOR AURA HZ MODELS Code AS22000 AS23000 AZ32001 AZ31001 AZ32000 AZ31000 AZ60000 AZ61000 AC10000 Item Support stand for Aura HZ 48 Support stand for Aura HZ 72 Double tap for vacuum Single tap for vacuum Double tap for gas Single tap for gass Double power point Single power point Drawer for all models of Aura HZ S-AURAHZ-R0-0704 Page 2 of 2 BIOAIR Instruments s.r.l. is part of group of company